Ultrasound System Specifications
The superb imaging and performance
capabilities of VINNO G60 give you the
confidence and efficiencies in your daily
exam by:
• World class image quality with
unmatched high-frequency range
• Versatile features and functions for
general imaging
• RF platform and Xcen technology
wideband probes
• Single touch automation function for easy
optimization
detail imaging than current advanced
platforms
• Thanks to the RF platform, it allows the
development of many RF-based processing
algorithms, which have ultra-premium
contrast and resolution imaging
• This unique platform is capable of
processing multiple data streams
simultaneously
• Up to 25MHz next generation digital
broadband and high resolution acoustic
beamforming
• The new 12 bit, low noise, digital circuitry,
with up to 180db dynamic range has
improved 2D performance and increased
Doppler sensitivity
• Directional-enhanced information
compiling for more tissue detail and
reduction of angle-generated artifacts
• Next generation adaptive image
processing for noise and artifact reduction
that improves tissue presentation and edge
definition
• Fully independent, triplex multiple mode
operation for easy in Doppler procedures
• Multi-processors allow simultaneous
mode changes and support for advanced
system functionality
Applications
• Abdomen
• Obstetric
• Gynecology
System Overview
• Cardiology
Architecture
• Urology
• The revolutionary RF platform, The First In • Vascular
The World, allows for more accurate
• TCD
information. This platform transfers all RF
• Small Parts
data for computing without any information • Pediatrics
loss. It has a much better advantage in
• Intra-operative
Imaging features
• Spatio_Temporal Image Correlation (STIC)
(Optional)*
• 2D grayscale imaging
• Harmonic imaging both in tissue harmonic • VOCAL (Volume calculation, Follicle count)
(Optional)*
and pulse inversion harmonic technologies
• SRV (Super Resolution Volume) to have
• VFusion, RF-based directional-enhanced
extreme contrast and resolution in thin
information compounding
volume
• VSpeckle, specialized and adaptive
imaging processing to remove speckle noise • Tomographic display (MCUT)
artifacts and enhance tissue edge for clarity • Inversion mode
• Magic Cut
and accuracy
• Smart Touch 3D/4D operation(Optional)
• VTissue, the advanced adaptive image
• Free View(Optional)
processing to compensate for sound and
• Auto NT* (Optional)
speed variation in different tissue*
• Real-time grayscale 4D
• Auto imaging optimization
• Three leads ECG function (Optional)
• Easy Comparative Function to compare
• Tissue Doppler (TD) mode*
previous exam
• Tissue Velocity Imaging (TVI) mode*
• Color M-mode
(Optional)
• Color Doppler imaging
• Tissue Velocity M (TVM) mode*
• Power Doppler imaging
• Integrated smart stress echo mode*
• Pulse wave Doppler imaging
(Optional)
• Simultaneous 2D and M mode
• Auto IMT function*
• Duplex 2D/PW Doppler
• Triplex 2D/Color/PW Doppler
Standard features
• High PRF pulsed wave Doppler
• Continuous wave Doppler
• Up to 25Mhz high frequency in system
• RF-based Zoom
platform. Up to 18MHz’s probes are
• FULL screen imaging to enlarge imaging
supported
size
• RF platform and RF data processing
• Dual real time imaging without
• Up to 1500 seconds standard cine storage
compromising imaging size
• 500GB hard drive
• Multi Angle M-mode with 360 degree
• SSD for quick boot up (Optional)
rotation (Optional)
• Integrated DVDRW
• PView for panoramic imaging (Optional)
• Integrated black/white thermal video
• TView for trapezoidal imaging
printer slot
• Elastography imaging(Optional)
• Patient information database
• Contrast imaging(Optional)
• Image archive on hard drive
• 3D imaging
• Quick store to USB memory stick
• 3D/4D HQR (High Quality rendering)
• Quick store to hard drive
(Optional)*
• Quick print to B/W and color thermal
video printer
• Network storage and printing
• Full measurement and analysis package
• Real time auto wave Doppler track and
calculations
• Vascular calculations
• Cardiac calculations
• OB calculations and tables
• Gynecological calculations
• Urological calculations
• Renal calculations
• Volume calculations
• Wireless networking for easy data sharing,
storage and printing (optional)
• Up-to-date connectivity and data
management solutions, wireless (optional),
LAN, integrated database
• DICOM compatibility*
• Four active probe ports, plus one dummy
probe port
• 5 USB ports
• 8 TGC slides
• Average 4 multiple adjustable frequency
in every probe and mode
• Up to 512 line density
• 1 DVI-D interface
• 1 Audio in interface; 1 Audio out interface
• 1 Speaker interface
• 1 RJ45 interface
Ergonomics
• Unique human oriented design for
comfort and convenience
• Fully articulating 21.5-inch high resolution
flat panel display with nearly infinite
positioning adjustments
• Up to 250mm up/down operation panel,
controlled by electric motor
• Fully articulating control panel including
height, swivel and front-back slide
adjustment
• Integrated footrest
• Integrated foot switch for configurable
function, such as Freeze, store etc
• Easy access DVD media drive
• 5 easy access transducer ports
• 5 transducer holders (removable for easy
cleaning)
• Automatic warming gel bottle holders
• Integrated touchable alphabetic keyboard
• Simple, easy and effective cable
management structure
Keyboard
• Highly sensitive 13 inch capacity touch
panel
• Intuitive, configurable and touchable
interactive operation interface
• Ergonomic hard keys for general
ultrasound operations
• 8 TGC slides, functionality at any depth
• Backlight keys
Image display screen
• 21.5 inch high resolution IPS , LED
technology, pixel resolution: 1920x1080
• Brightness, contrast and color
temperature adjustment
• Big angel swivel and tilting capability
Peripherals
• B&W thermal video printer: Sony UPD897MD (optional)
• Color thermal video printer: Sony UPD25MD (optional)
• Memory stick (optional)
Dimensions and Weight
G2-5C Broadband Curved Array
• Height: 1320-1570mm
• Width: 605mm
• Depth: 900-1050mm
• Weight: 75kg
• Field of view: 66 degree
• Convex radius: 50mm
• Application: abdomen, OB/Gyn, urology,
pediatric
• Frequency range: 1.4 -5.6MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
•Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
•Reusable biopsy guide available
Electrical Power
• Voltage: 100-240V AC
• Frequency: 50/60Hz
• Power: Max. 600VA for console only
Transducers
Transducer Technology
• Xcen technology for wideband frequency
• Pure wave technology for high resolution
imaging
• Unique and high technical Xcen probe
connector to adapt all different type of
VINNO product models
Transducer types
• Convex array
• Linear array
• Phase array
• 4D probe
• Endocavity probe
• Micro-convex array
Transducer selection
• Electronic switching of transducers
• User customizable imaging presets for
each transducer and application
• Automatic dynamic receiving focus in all
transducers
• Multiple adjustable transmit focal zone,
up to 8 focal zone
F2-5C Broadband Curved Array
• Field of view: 59 degree
• Convex radius: 59.5mm
• Application: abdomen, OB/Gyn, urology,
pediatric
• Frequency range: 1.6 -5.5MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
•Reusable biopsy guide available
D3-6C broadband curved array volume
probe
• Field of view: 78 degree
• Convex radius: 40mm
• Application: abdomen, OB/Gyn, urology
• Frequency range: 1.9 - 7MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic, 3D/4D grayscale
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
G4-9M broadband micro convex array
X4-12L broadband linear array
• Field of view: 138 degree
• Convex radius: 12mm
• Application: pediatric, abdomen, cardiac
• Frequency range: 3 - 10MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
• Fine pitch, high resolution
• Applications: vascular, small parts
• Frequency range: 4.5 -13MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
G4-9E broadband micro convex endocavity
array
• Field of view: 138 degree
• Convex radius: 12mm
• Application: Ob/Gyn, urology
• Frequency range: 3 - 10MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
• Reusable biopsy guide available
D4-9E broadband micro convex 4D
endocavity array
• Field of view: 125 degree
• Convex radius: 10mm
• Application: Ob/Gyn, urology
• Frequency range: 3 - 10MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic , 3D/4D grayscale,
• Multi-imaging frequency setting in 2D,
3D/4D, Harmonic, color Doppler and Wave
Doppler modes
X6-16L broadband linear array
• Fine pitch, high resolution
• Applications: vascular, small parts
• Frequency range: 6.5 -18MHz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
I4-11T broadband linear array
• Fine pitch, high resolution
• Frequency range: 4.2-11Mhz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
G1-4P phased array
• Applications: cardiac, abdomen, Ob/Gyn,
Urology
• Frequency range: 1.35-4.3Mhz
• Pulsed wave Doppler, continuous wave
Doppler, color Doppler, power Doppler,
harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
S1-6P phased array
• Single Crystal technology
• Applications: cardiac, abdomen, Ob/Gyn,
Urology
• Frequency range: 1.9-7Mhz
• Pulsed wave Doppler, continuous wave
Doppler, color Doppler, power Doppler,
harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave Doppler
modes
U5-15LE broadband linear array
• Fine pitch, high resolution
• Applications: small parts, specially for
breast, vascular
• Footprint: 52mm
• Frequency range: 5 -15Mhz
• Pulsed wave Doppler, color Doppler,
power Doppler, harmonic
• Multi-imaging frequency setting in 2D,
Harmonic, color Doppler and Wave
Doppler modes
Advanced Imaging controls
VFusion
• Available on all transducers and for 2D,
3D/4D (except phase array probe)
• Up to 5 levels of directional imaging
fusion to enrich information
• Operate in conjunction with VSpeckle,
harmonic imaging
VSpeckle
• Available on all transducers and for 2D,
3D/4D
• Virtually eliminate speckle noise artifact
and dynamically enhances tissue margins
• Selectable multiple levels of speckle noise
reduction and smoothing
• Operates in conjunction with VFusion and
harmonic imaging
VTissue *
• Advanced imaging processing to adapt to
the speed of the ultrasound variation in
different tissue
• Improved detail resolution and
conspicuity of lesions
• Presentable sound and speed in different
applications
• One touch operation to ease diagnosis
SRV (Super Resolution Volume)
• Extreme contrast and spatial resolution in
thin volume
• Small volume sweep angle
• High volume rate
• Visual able the tissue information in a
thick slice
• Better detection in diffuse lesions of
organs
3D/4D HQR (High Quality Rendering)
(Optional)
• Amazing high image quality
• Extreme realistic rendering images
• Similar operation as normal rendering
VOCAL (Volume Calculation)
(Optional)
• Automatic 3D follicle detection
(number&size)
• Definition of a shell contour
• Volume calculation of ultrasound tissue
inside a shell contour
Spatio-Temporal Image Correlation (STIC)
(Optional)
• Visualize the fetal heart or an artery
• One complete heart cycle represented
• Using 3D static acquisition
Inversion mode
• This render mode is used to display
anechoic structures such as vessels
• It invert the gray values of the rendered
image, such as black image information
become white and vice versa
Magic Cut
• Ability to edit images, make possible to
cut away structure obstructing the view in
the ROI
• Several cutting methods available
Advanced Imaging controls (cont.)
Smart Touch 3D/4D Operation(Optional)
• Fully utilize touch panel possibility for
easy operation, such as rotation 3D
rendering image, move ROI, create line by
finger
Free View(Optional)
• Provide any plane view to visualize the
internal tissue information
• Improve the contrast resolution to
facilitate the detection of diffuse lesions in
organs
Tissue Doppler (TD)
• Present wall motion spectrum by using
Doppler principle
• Provide wall motion direction and velocity
information
Tissue Velocity Imaging (TVI) (Optinal)
• Color codes the velocities in tissue
• Present tissue color imaging by using
Doppler principle
• This color image is overlaid onto the 2D
image
• Captures low flow but high amplitude
signals associated with wall motion
Stress Echo (Optional)
• Review and analyze wall segment
information
• Continuous capture or selectable capture
• Provides selectable protocol template for
exercise
Auto NT (Nuchal Translucency )
measurement
• Automatically detect Nuchal Translucency
in interest box
• Automatically report thickness result of
NT
Auto IMT (Intima-Media Thickness)
measurement
• Automatically detect intima media
thickness in interest box
• Automatically report the result of IMT
• Available in linear probe
Next generation RF-based image
processing
• Available on all imaging transducers in 2D
grayscale modes
• Virtually eliminates speckle noise artifact
and dynamically enhance tissue edge
• Operates with other real-time processing
algorithms
Imaging modes
2D Imaging
Harmonic Imaging
• Pre-defined ATGC (adaptive temporal gain
compensation) curves optimized for
consistently excellent imaging
• B/M acoustic output: 0-100%
• Depth: able to adjust from 1 to 36cm
• Select between 1 to 8 transmit focal zones
• Reverse function: on/off
• VFusion function
• VSpeckle function
• Harmonic imaging both tissue harmonic
and phase inversion
• Cineloop image review
• Selectable 2D line density
• Dual imaging with independent cineloop
• 256(8 bit) gray level
• Up to 8 focus zone adjustable
• Multiple color maps with chroma imaging
• FULL screen imaging to larger image size
• Multi frequency: probe dependent
• Gray filter: 6 steps
• Persistence: 8steps
• Selectable image angles, probe
dependent
• Gain: 0-100%
• Dynamic range: 30-180 db
• VSharpen to enhance edge contrast
• Smooth to improve spatial resolution
• EdgeEnhance to improve detail
information and contrast
• VNear to enhance SNR of near field
• Supports both tissue harmonic and phase
inversion imaging (transducer and
frequency dependence)
• Second harmonic processing to reduce
artifacts and improve image clarity
• Maximize detail resolution and enhance
contrast
• Available on all imaging transducers
• Extends high performance imaging
capabilities to all patient body types
M mode
• Selectable sweeping rates
• Time marks: 0.025 – 0.5 second
• Selectable display format prospective or
retrospective (1/3-2/3, 1/2-1/2, 2/3-1/3,
side by side 1/2-1/2, side by side 1/3-2/3,
full screen)
• Chroma colorization with multiple color
maps
• Cineloop review for retrospective analysis
of M-mode data
• 256 gray levels
Color Doppler mode
• Available on all imaging transducers
• Automatically adapts transmit and receive
bandwidth processing based on the color
box position
• Cineloop review with full playback control
• Steering on linear array transducers
• Selectable in baseline, line density, flash
reduction, persistence, maps, frequency,
PRF, wall filter, packet size, color level,
sensitivity, focus position, acoustic power,
and smooth
• Color gain
• Region of interest
• Baseline invert
• Simultaneous mode during PW mode
• Smoothing
• Wall filter
• Zoom
Power Doppler mode
• High sensitive mode for small vessel
visualization
• Available on all transducers
• Cineloop review
• Multiple color maps
• Individual controls for gain
• Selectable baseline, line density, flash
reduction, persistence, maps, frequency,
PRF, wall filter, packet size, color level,
sensitivity, focus position, acoustic power,
and smooth
• Adjustable region of interest
Pulsed Wave (PW) Doppler
• Ultra high resolution spectral FFT rate
• Angle correction with automatic velocity
scale adjustment
• Normal, invert display around horizontal
zero line
• Selectable gray filter, dynamic range,
frequency, PRF, wall filter, baseline, angel
correct, sample volume
• Selectable sweep speeds: 8 steps
• Maximum velocity range: 12m/s
• PW acoustic output: 0-100%
• Selectable low frequency signal filtering
with adjustable wall filter settings
• Selectable grayscale curve for optimal
display
• Selectable chroma colorization maps
• Selectable display format prospective or
retrospective (1/3-2/3, 1/2-1/2, 2/3-1/3,
side by side 1/2-1/2, side by side 1/3-2/3,
full screen)
• Auto function to optimize spectral
Doppler displ.
• Digitally enhanced stereo output
• 256 gray levels
• Post-processing in frozen mode includes
map, baseline, invert and chroma
• Simultaneous or duplex mode of
operation
• Simultaneous 2D, color Doppler, pulsed
Doppler
• High PRF capability in all modes including
duplex and triplex
Continuous Wave Doppler (CWD)
• Cardiac sector array transducer only
• Maximum velocity range: 19m/sec
• User can measure distance and area
• Measurement can be made on individual
frames during cineloop review
• Available on linear transducers
Elastography imaging(Optional)
• Shows the spatial distribution of tissue
elasticity properties in a region of interest
to estimate the strain before and after
tissue distortion caused by external force
• The strain estimation is scaled by color to
have smooth distribution display
• Have quality index to indicate if there is
proper external force
Contrast imaging(Optional)
• Support contrast imaging in both 2D and
3D volume
• By contrast agent, imaging is enhanced
within vessel which agent flow
• Have one button push to destroy the
agent. Useful in the bubble wash-in
characteristics of anatomy being scanned
3D/4D
• 3D/4D rotation
• Grayscale imaging controls
• Selectable rendering approaches
• Unique high quality rendering algorithm
• Selectable gray maps
• Multi slide cutting
• Cineloop 3D (MCUT)
• Review volume
PView (Optional)
• Real time extended field of view
composite imaging
• Ability to back up and realign the image
during acquisition
• Full zoom, cineloop review and image
rotation capabilities
TView
• Expand view of scanning
• Available on linear transducers
Auto
• Intelligent one button automatic
optimization in 2D and Doppler modes
• Automatically adjust PRF and baseline
in Doppler
Stress Echo (Optional)*
• Acquisition of single-frames or fullmotion digital clips in any modes
(including 2D,
color flow, power Doppler, etc)
• Length of acquired images is useradjustable
• Default stress protocols
• Flexible user defined stress protocols
Tissue Doppler Imaging (TD) *
• Use Doppler methodology to image
movement of tissue
• Available on all sector transducer
for cardiac imaging
• Gain
Tissue Velocity Imaging (TVI)
(Optional)*
• Available on all sector transducer
for cardiac imaging
• Gain
• Velocity
Touch Panel Interface
M Mode
2D mode
• New patient
• BodyPattern
• Archive
• Comments
• End exam
• Sys setting
• Probe&App
• L/R format
• U/D format
• Maps
• Dynamic range
• Acoustic power
• Sweep speed
• Gray filter
• VSharpen
• ECG
• New patient
• BodyPattern
• Archive
• Comments
• End exam
• Sys setting
• Probe&App
• PView
• Fullscreen
• L/R
• U/D
• Center line
• VTissue*
• VSpeckle
• VFusion
• Gray Filter
• Persistence
• Display Format
• Image reference
• Maps
• Frequency
• Focus position
• Focus #
• Dynamic Range
• Line density
• VSharpen
• Biopsy
• Image angle
• Focus width
• Smooth
• Acoustic power
• Contrast imaging
• Elastosonography
• EdgeEnhance
• Vnear
CF mode
• New patient
• BodyPattern
• Archive
• Comments
• End exam
• Sys setting
• Probe&App
• Invert
• Full Screen
• L/R
• U/D
• Baseline
• Flash Reduction
• Line density
• Persistence
• Display format
• Image reference
• Maps
• Frequency
• PRF
• Wall filter
• Packet size
• Colorlevel
• Sensitivity
• Focus position
• Acoustic power
• Smooth
PW/CW mode
• New patient
• BodyPattern
• Archive
• Comments
• End exam
• Sys setting
• Probe&App
• Invert
• Triplex
• Display format
• Sweep speed
• Gray filter
• Dynamic range
• Trace sensitive
• Auto trace
• Mode/direction
• Maps
• Frequency
• PRF
• Wall filter
• Baseline
• Steer
• Sample volume
• Volume
• Spectrum optimize
• Acoustic power
3D mode
• Comments
• BodyPattern
• Back to B
• Start3D
• ROI shape
• Render resolution
• Render
• Display format
• Image reference
• View
• Gray map
• VSpeckle
• Quality
• Threshold
• Transparency
• Volume angle
• Movement step (after data acquisition)
• Light position (after data acquisition)
• Rotation angle (after data acquisition)
• Rotation direction (after data acquisition)
• 3DMcut(after data acquisition)
• Magic Cut (after data acquisition)
• Free View(after data acquisition)
• Smart Touch 3D/4D operation(after data
acquisition)
4D mode
• Comments
• Body Pattern
• Back to B
• Start 4D
• ROI shape
• Movement step
• Rotation direction
• Render
• Display format
• Image reference
• View
• Gray map
• VSpeckle
• Quality
• Threshold
• Transparency
• Volume angle
• 3DMcut(after data acquisition)
• Smart touch 3D/4D operation(after data
acquisition)
System Feature
Display modes
• Simultaneous capability
• 2D/PW/CW
• 2D/CF or PDI
• 2D/M
• Dual, 2D/2D
• Dual, 2D/2D+CF or PDI
• Dual, duplex and triplax
• Duplex and Triplex mode
• Quad display in 3D/4D application
• 9 slice images display in 3D/4D
application
• Time line display
• Independent dual 2D/PW or CW
• Timed based sweep update mode
Display annotation
• Institution/hospital name
• Date: 2 types selectable, YY/MM/DD,
MM/DD/YY
• Time: 2 types selectable, 24hours and 12
hours
• Operator identification
• Patient name, first, last
• Patient identification: 30 characters
• Gestational age from LMP/EDC/GA/BBT
• VINNO image symbol: Ginkgo leaf
• Power output index
• MI: mechanical index
• TIS: thermal index soft tissue
• TIC: thermal index cranial (Bone)
• TIB: thermal index bone
• Probe orientation marker: coincide with a
probe orientation marking on the probe
• Gray/color bar
• Measurement result window
• Probe type
• Application name
• Image depth
• Imaging parameters by mode
• 2D/M mode: acoustic power output,
gain, frequency, frame rate, dynamic
range
• Color mode: color acoustic power
output, color gain, color flow
frequency,
PRF, wall filter
• PW/CW mode: Doppler acoustic
power output, Doppler gain, Doppler
frequency, PRF, wall filter, sample
depth
• Focus zone marker
• Body pattern
• PW and CW scale markers: time/speed
• M scale markers: time/depth, time
• System measurement display
• System message display
• Biopsy guide line
• Heart rate
Cineloop
• Acquisition, storage in memory and
display of up to 15000 frames, 1500
seconds long of 2D, color and PW/CW
images for review
Compare
• Pull related exams’ images into the report
• Compare live imaging with stored imaging. • Write comments in the report
• Print report through network or local
All live imaging’s parameters are same as
printer
stored imaging
Quick save feature
Connectivity
• The system provides quick save function
through USB stick, internal/external HDD,
DVD during or after exam
• Configurable saving file format, VRD
(VINNO Raw Data), DICOM, PNG and AVI
• Standard connectivity features
• Local print to on-board or off-board
video printers through USB port
• Page report print
• Image export to removable media
(DVD, external HDD, USB stick)
• Network linkage
• Image export to network storage
servers*
• DICOM export and retrieve *
• Integrated DVDRW
• Support standard DVD media
• Data storage formats include VRD,
DICOM, PNG, AVI
• VRD and DICOM images stored in disc
can be recalled on the VINNO system
• PNG and AVI images can be played on
normal computers
• On-board patient exam storage
• Direct digital storage of static image
or cineloop images to internal hard
disk drives
• Fully integrated user interface
Physio (Optional)
• One 3-lead ECG input
• Gain, sweep rate and display position
controls
• Automatic heart rate calculation and
display
• Fault condition display
Archive
• Patient data input which include patient
ID, name, nationality, birth date, sex, exam
physician, quality check, exam operator
• Physical data such as weight, height
• Patient exam management
• Patient exam images storage and
management
• Import VRD format data into the system
from outside media, such as USB stick,
external HDD, DVD
• Export patient data into outside medias
Report
• Automatically pull patient data into the
report
• Automatically load measurement
worksheet into the report
Probes/application
• Selectable multiple applications
• Edit exist application preset
• Edit user defined preset
• Rename preset
• Return to factory preset
• Quick save user defined parameters in
related application
Safety Conformance
• Regulatory Notice:
This device is tested to meet all applicable
requirements in relevant. According to
93/42 EEC, it is class IIa medical device.
• Conformity to Standards:
• IEC 60601-1 E3:2005 Medical
electrical equipment - Part 1: General
requirements for basic safety and
essential performance
• IEC 60601-1-1:2000 Safety
requirements for medical electrical
systems
• IEC 60601-1-2:2007 Electromagnetic
compatibility - Requirements and
tests
• IEC 60601-1-4:2000 Programmable
electrical medical Systems
• IEC 60601-1-6:2010 Usability
• IEC 60601-2-37:2005 Medical
electrical equipment Particular
requirements for the safety of
ultrasonic medical diagnostic and
monitoring equipment
• IEC 61157:2007 Declaration of
acoustic output parameters
• ISO 10993-1:2009 Biological
evaluation of medical devices
• IEC 62366:2007 Medical devices
Application of usability engineering to
medical devices
• Council Directive 93/42/EEC on M.D.
• Directive 2002/96/EC on Waste
Electrical and Electronic Equipment
• Directive 2006/42/EC on Machinery
Measurement and Analysis
Generic Measurement in 2D mode
• Depth
• Distance
• Perimeter
• Length and width method
• Ellipse method
• Polygon method
• Spline method
• Tracing method
• Area
• Length and width method
• Ellipse method
• Polygon method
• Spline method
• Tracing method
• Volume
• Single line method
• Dual line method
• Triple line method
• Single ellipse method
• Single ellipse and single line method
• Angle
• Stenosis
• Diameter method
• Square meter method
• A and B ratio
• Diameter ratio
• Square meter ratio
Generic Measurement in M mode
• Depth
• Distance
• Time
• Speed
• Heart rate
• Stenosis
• A and B ratio
• Diameter ratio
• Time ratio
• Speed ratio
• Time mean speed in each stroke
volume
• Cardiac output
• Heart rate
Abdominal Measurement
• General abdomen
• Difficult abdomen
• Kidney
• Renal vessel
• Abdominal trauma
Generic Measurement in PW mode
Small Part Measurement
• Speed (include PV (Peak Velocity))
• Time (include AT (Accelerate Time))
• Acceleration
• PS (Peak Speed in systole period)
• ED (The speed in the end of diastole
period)
• MD (Minimum speed in diastole period)
• TAMAX (maximum speed in time average)
• TAMEAN (mean speed in time average)
• TAMIN (minmum speed in time average)
• PI (Pulsatility Index)
• RI (Resistance Index)
• PS and ED ratio
• ED and PS ratio
• A and B ratio (A/B ratio)
• Speed ratio
• Time ratio
• Acceleration ratio
• FLOWVOL (Flow Volume)
• MaxPG ( maximum pressure gradient)
• MeanPG (Mean pressure gradient)
• SV ( Stroke Volume)
• Each volume diameter cardiac
• Thyroid
• Breast
• Testis
• Musculoskeletal
• Upper and lower extremity joint
• Nerve block
Vessel Measurement
• Carotid artery
• Upper artery
• Upper vein
• Lower artery
• Lower vein
• Vessel puncture
• Transcranial Doppler
Gynecology Measurement
• Uterus and Plevis
• Follicle
Urology Measurement
• Bladder
• Prostate
• Renal
• Kidney and ureter
• Pelvic Floor dysfunction
Pediatric Measurement
• Neonatal Head
• Neonatal Abdomen
• Pediatric Abdomen
• Pediatric Hip
• FAST
Obstetrics Measurement
• OB Early
• OB Mid
• OB Late
• Fetal Heart
Cardiac Measurement
• General
• LV
• MV
• Ao
• AV
• LA
• RV
• TV
• PV
• RA
• System
VINNO Technology (Suzhou) Co., Ltd
VINNO is focusing on producing premium
diagnostic ultrasound development to
provide customer clinical value through
Continuous Innovation, Excellent
Performance and Accessible Solutions.
Thank you for your interest in VINNO.
You can contact us by phone and email
(below) or contact our local representatives.
VINNO Technology (Suzhou) Co., Ltd
5F, C8, 218 Xinghu Rd, Suzhou Industrial Park,
PR China (215123)
Tel: +86 512 62873806
Fax: +86 512 62873801
email address: vinno@vinno.com
website: www.vinno.com
Download PDF
Similar pages