Nortel Secure Network Access Switch 4050 Installation Guide

Part No. 320846-A
December 2005
4655 Great America Parkway
Santa Clara, CA 95054
Nortel Secure Network Access
Switch 4050 Installation Guide
*320846-A*
2
Copyright © 2005 Nortel Networks. All rights reserved.
The information in this document is subject to change without notice. The statements, configurations, technical data, and
recommendations in this document are believed to be accurate and reliable, but are presented without express or implied
warranty. Users must take full responsibility for their applications of any products specified in this document. The
information in this document is proprietary to Nortel Networks.
The software described in this document is furnished under a license agreement and may be used only in accordance
with the terms of that license. The software license agreement is included in this document.
Trademarks
Nortel, Nortel Networks, the Nortel logo, and the Globemark are trademarks of Nortel Networks.
Adobe and Acrobat Reader are trademarks of Adobe Systems Incorporated.
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation.
The asterisk after a name denotes a trademarked item.
Restricted rights legend
Use, duplication, or disclosure by the United States Government is subject to restrictions as set forth in subparagraph
(c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.
Notwithstanding any other license agreement that may pertain to, or accompany the delivery of, this computer software,
the rights of the United States Government regarding its use, reproduction, and disclosure are as set forth in the
Commercial Computer Software-Restricted Rights clause at FAR 52.227-19.
Statement of conditions
In the interest of improving internal design, operational function, and/or reliability, Nortel Networks reserves the right to
make changes to the products described in this document without notice.
Nortel Networks does not assume any liability that may occur due to the use or application of the product(s) or circuit
layout(s) described herein.
Portions of the code in this software product may be Copyright © 1988, Regents of the University of California. All
rights reserved. Redistribution and use in source and binary forms of such portions are permitted, provided that the above
copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials,
and other materials related to such distribution and use acknowledge that such portions of the software were developed
by the University of California, Berkeley. The name of the University may not be used to endorse or promote products
derived from such portions of the software without specific prior written permission.
SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED
WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
In addition, the program and information contained herein are licensed only pursuant to a license agreement that contains
restrictions on use and disclosure (that may incorporate by reference certain limitations and notices imposed by third
parties).
320846-A
3
International regulatory statements of conformity
This is to certify that the Nortel Secure Network Access Switch 4050 was evaluated to the international regulatory
standards for electromagnetic compliance (EMC) and safety and was found to have met the requirements for the
following international standards:
•
•
•
EMC - Electromagnetic Emissions – CISPR 22, Class A
EMC - Electromagnetic Immunity – CISPR 24
Electrical Safety – IEC 60950, with CB member national deviations
Further, the equipment has been certified as compliant with the national standards as detailed below.
National electromagnetic compliance (EMC) statements of compliance
FCC statement (USA only)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it
may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct
the interference at their own expense.
ICES statement (Canada only)
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (Nortel Secure Network Access Switch 4050) does not exceed the Class A limits for radio-noise
emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (Nortel Secure Network Access Switch 4050) respecte les limites de bruits radioélectriques
visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère
des Communications du Canada.
CE marking statement (Europe only)
EN 55 022 statements
This is to certify that the Nortel Secure Network Access Switch 4050 is shielded against the generation of radio
interference in accordance with the application of Council Directive 89/336/EEC. Conformity is declared by the
application of EN 55 022 Class A (CISPR 22).
EN 55 024 statement
This is to certify that the Nortel Secure Network Access Switch 4050 is shielded against the susceptibility to radio
interference in accordance with the application of Council Directive 89/336/EEC. Conformity is declared by the
application of EN 55 024 (CISPR 24).
Nortel Secure Network Access Switch 4050 Installation Guide
4
CE Declaration of Conformity
This product conforms to the provisions of the R&TTE Directive 1999/5/EC.
VCCI statement (Japan/Nippon only)
This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) for
information technology equipment. If this equipment is used in a domestic environment, radio disturbance may arise.
When such trouble occurs, the user may be required to take corrective actions.
BSMI statement for Nortel Secure Network Access Switch 4050 (Taiwan only)
This is a Class A product based on the standard of the Bureau of Standards, Metrology and Inspection (BSMI) CNS
13438, Class A.
MIC notice for Nortel Secure Network Access Switch 4050 (Republic of Korea only)
This device has been approved for use in Business applications only per the Class A requirements of the Republic of
Korea Ministry of Information and Communications (MIC). This device may not be sold for use in a non-business
application.
Observe the Regulatory Marking label on the bottom surface of the chassis for specific certification information
pertaining to this model. Each model in the Ethernet Switch Series which is approved for shipment to/usage in Korea is
labeled as such, with all appropriate text and the appropriate MIC reference number.
National safety statements of compliance
CE marking statement (Europe only)
EN 60 950 statement
This is to certify that the Nortel Secure Network Access Switch 4050 is in compliance with the requirements of EN 60
950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries
have been evaluated for compliance.
320846-A
5
NOM statement Nortel Secure Network Access Switch 4050 (Mexico only)
The following information is provided on the devices described in this document in compliance with the safety
requirements of the Norma Oficial Méxicana (NOM):
Exporter:
Nortel Networks
600 Technology Park Drive
Billerica MA 01821 USA
Importer:
Nortel Networks de México, S.A. de C.V.
Avenida Insurgentes Sur #1605
Piso 30, Oficina
Col. San Jose Insurgentes
Deleg-Benito Juarez
México D.F. 03900
Tel:
52 5 480 2100
Fax:
52 5 480 2199
Input:
Nortel Secure Network Access Switch 4050
100-240 VAC 6.3 A 50-60 Hz
Información NOM (unicamente para México)
La información siguiente se proporciona en el dispositivo o en los dispositivos descritos en este documento, en
cumplimiento con los requisitos de la Norma Oficial Méxicana (NOM):
Exportador:
Nortel Networks
600 Technology Park Drive
Billerica MA 01821 USA
Importador:
Nortel Networks de México, S.A. de C.V.
Avenida Insurgentes Sur #1605
Piso 30, Oficina
Col. San Jose Insurgentes
Deleg-Benito Juarez
México D.F. 03900
Tel:
52 5 480 2100
Fax:
52 5 480 2199
Embarcar a:
Nortel Secure Network Access Switch 4050
100-240 VAC 6.3 A 50-60 Hz
Nortel Secure Network Access Switch 4050 Installation Guide
6
320846-A
7
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Text conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Hard-copy technical manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
How to get help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installation package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Switch physical features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Chapter 2
Installation Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Ventilation safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Electrical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Mechanical safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Installing the switch in a rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Installing the switch on a shelf or tabletop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Supplying power to the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Connecting the power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Setting up terminal access to the switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Terminal requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Console connector and pin assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Establishing a console connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Troubleshooting installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Nortel Secure Network Access Switch 4050 Installation Guide
8
Contents
Appendix A
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Hardware and power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Console port setup parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
LAN connection speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Regulatory specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Appendix B
Safety Message Translations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
320846-A
9
Preface
This guide provides instructions to install the Nortel Secure Network Access
Switch 4050 (Nortel SNAS 4050).
The guide is intended for network component installers, systems administrators,
and switch administrators who
•
•
•
•
understand networks, Ethernet bridging, and Internet Protocol (IP) routing.
understand networking concepts, terminology, and topology.
prepare, install, and configure components on LAN and WAN networks.
understand and follow safety practices during hardware installation
procedures.
Before you begin
Ensure that the area where you install the Nortel Secure Network Access
Switch 4050 meets the following environmental requirements:
•
•
•
•
•
•
•
•
Ambient temperature between 32° F and 104° F (0° C and 40° C)
Relative humidity between 5% and 85% non-condensing
No nearby heat sources such as hot air vents or direct sunlight
No nearby sources of severe electromagnetic noise
No excessive dust
Adequate power source within six feet; one 15-Amp circuit required
At least 2 inches (5.08 cm) on each side of the switch unit for ventilation
Adequate space at the front and rear of the switch for access to cables
If you are installing a single Nortel Secure Network Access Switch 4050 on a
table or shelf, ensure that the surface can support at least 15 to 20 pounds (7 to 9
kilograms).
Nortel Secure Network Access Switch 4050 Installation Guide
10
Preface
Text conventions
This guide uses the following text conventions:
angle brackets < >
Indicate that you choose the text to enter based on the
description inside the brackets. Do not type the
brackets when entering the command.
Example: If the command syntax is
ping <ip_address>, you enter
ping 192.32.10.12
bold body text
Indicates objects such as window names, dialog box
names, and icons, as well as user interface objects such
as buttons, tabs, and menu items.
bold Courier text
Indicates command names, options, and text that you
must enter.
Example: Use the dinfo command.
Example: Enter show ip {alerts|routes}.
braces {}
Indicate required elements in syntax descriptions where
there is more than one option. You must choose only
one of the options. Do not type the braces when
entering the command.
Example: If the command syntax is
show ip {alerts|routes}, you must enter either
show ip alerts or show ip routes, but not both.
brackets [ ]
Indicate optional elements in syntax descriptions. Do
not type the brackets when entering the command.
Example: If the command syntax is
show ip interfaces [-alerts], you can enter
either show ip interfaces or
show ip interfaces -alerts.
ellipsis points (. . . )
Indicate that you repeat the last element of the
command as needed.
Example: If the command syntax is
ethernet/2/1 [<parameter> <value>]... ,
you enter ethernet/2/1 and as many
parameter-value pairs as needed.
320846-A
Preface
11
italic text
Indicates variables in command syntax descriptions.
Also indicates new terms and book titles. Where a
variable is two or more words, the words are connected
by an underscore.
Example: If the command syntax is
show at <valid_route>,
valid_route is one variable and you substitute one
value for it.
plain Courier
text
Indicates command syntax and system output, for
example, prompts and system messages.
Example: Set Trap Monitor Filters
separator >
Shows menu paths.
Example: Protocols > IP identifies the IP command on
the Protocols menu.
vertical line |
Separates choices for command keywords and
arguments. Enter only one of the choices. Do not type
the vertical line when entering the command.
Example: If the command syntax is
show ip {alerts|routes}, you enter either
show ip alerts or show ip routes, but not
both.
Hard-copy technical manuals
To access Nortel technical documentation online, open your browser and go to the
Nortel Web site at www.nortel.com/support.
You can download and print technical manuals and release notes directly from the
Nortel web site. Use Adobe* Reader* to open the manuals and release notes,
search for the sections you need, and print them on most standard printers. Go to
Adobe Systems at the www.adobe.com URL to download a free copy of the
Adobe Reader.
Nortel Secure Network Access Switch 4050 Installation Guide
12
Preface
How to get help
If you purchased a service contract for your Nortel product from a distributor or
authorized reseller, contact the technical support staff for that distributor or
reseller for assistance.
If you purchased a Nortel service program, use the www.nortel.com/support web
page to contact Nortel for assistance.
320846-A
13
Figures
Figure 1
Front panel view with bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 2
Bezel removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 3
Front panel view without bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 4
Bezel attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 5
Rear panel view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 6
Setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Nortel Secure Network Access Switch 4050 Installation Guide
14
Figures
320846-A
15
Tables
Table 1
Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 2
Front panel features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 3
Rear panel features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 4
Ports 1 and 2 LED status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 5
Ports 3 and 4 LED status indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 6
Console configuration parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 7
Pinouts for DB-9 console connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 8
Hardware specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 9
Power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 10
Console port setup parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 11
LAN connection speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 12
Safety specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 13
Emissions specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 14
Certification marks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Nortel Secure Network Access Switch 4050 Installation Guide
16
Tables
320846-A
17
Chapter 1
Overview
This chapter covers the following topics:
Topic
Page
Installation package contents
17
Switch physical features
18
Installation package contents
Table 1 lists the contents of the Nortel Secure Network Access Switch 4050
installation package.
Table 1 Package contents
Item
Purpose
North American power cord
To meet North American power
specifications. Not supplied if an alternate
country cord is ordered.
European power cord
To meet European power specifications.
Not supplied if an alternate country cord is
ordered.
Console cable
To connect the Nortel SNAS 4050 to a
personal computer or local terminal
Bezel adapter kit with (2) brackets and
(4) rubber feet
To install the Nortel SNAS 4050 on a flat
surface
Set of (4) mounting screws
To install the Nortel SNAS 4050 in a rack
Nortel Secure Network Access Switch 4050 This guide
Installation Guide (320846-A)
Nortel Secure Network Access Switch 4050 Installation Guide
18
Chapter 1 Overview
Switch physical features
The Nortel Secure Network Access Switch 4050 front panel has buttons and
indicators for normal operation. The front panel bezel is removable for access to
the CD drive. The switch rear panel has port and power supply access.
Front panel
Figure 1 shows the Nortel Secure Network Access Switch 4050 front panel view.
Table 2 describes front panel features.
Figure 1 Front panel view with bezel
Amber system status LED
Reset button
System power LED
Hard disk activity LED
Power button
Table 2 Front panel features
320846-A
Indicator or Button
Description
Amber system status LED
On when system needs attention due to power
supply, fan, CPU, or device temperature problems
Hard disk drive activity LED
Blinks during hard disk drive activity
Reset button
Reboots the switch
Power button
Turns on switch power
System power LED
Shows green when power is on
Chapter 1 Overview
19
Removing the front panel bezel
Remove the bezel for CD drive access. Replace the bezel when you are done.
To remove the bezel, follow these steps:
1
On the left front of the unit, locate and open the bezel release flap (Figure 2).
2
Grasp the bezel and slide the bezel to the right until disengaged.
3
Remove the bezel from the faceplate.
Figure 2 Bezel removal
Figure 3 shows the front panel without the bezel.
Figure 3 Front panel view without bezel
CD Drive
Face plate LEDs and buttons
USB Connectors
Nortel Secure Network Access Switch 4050 Installation Guide
20
Chapter 1 Overview
Attaching the front panel bezel
Attach the bezel for normal operation.
To attach the bezel, follow these steps:
1
Align the bezel on the faceplate slightly to the right of the front panel.
2
With the release flap open, engage the bezel onto the track and slide it to the
left until it locks into place (Figure 4).
3
Close the release flap.
Figure 4 Bezel attachment
320846-A
Chapter 1 Overview
21
Rear panel
Figure 5 shows the Nortel Secure Network Access Switch 4050 rear panel view.
Table 3 describes rear panel features.
Figure 5 Rear panel view
Console Port
Power supply fan
AC Power socket
Power switch
Left LED
Port 1
Right LED
1
2
Ports
3
4
Table 3 Rear panel features
Item
Purpose
Power supply fan
Cools the power supply
AC power socket
Connects to the power source
Console port
Connects to the terminal or PC terminal emulator
LAN ports
Connect to the network
All ports are Gigabit 10/100/1000 LAN ports. Ports 1 and 2 are on-board ports.
Ports 3 and 4 are NIC (Network Interface Controller) ports. Status LEDs for each
port are located above the port. (Port 1 LED locations are shown in Figure 5.)
Nortel Secure Network Access Switch 4050 Installation Guide
22
Chapter 1 Overview
Table 4 explains LED status indicators for ports 1 and 2. Table 5 explains LED
status indicators for ports 3 and 4.
Table 4 Ports 1 and 2 LED status indicators
Port speed Left LED
Right LED
Status
10 Mb/s
Off
Green flashing Port operates at 10 Mb/s. Cable connection
between the port and network device (switch, hub,
or router) is working. Port and network devices are
receiving power and the NIC driver is operating
properly.
When the right LED is flashing, the port is sending
or receiving network data. The flash frequency
varies with the amount of network traffic.
100 Mb/s
Yellow/
flashing
Off
Port operates at 100 Mb/s. Cable connection
between the port and network device is good.
When the left LED is flashing, the port is sending
or receiving network data.
1000 Mb/s On or flashing On or flashing Port operates at 1000 Mb/s. Cable connection
between the port and network device is good.
When the LEDs are flashing, the port is sending or
receiving network data.
All speeds
Off
Off
One or more above conditions is not met.
Table 5 Ports 3 and 4 LED status indicators
Port speed Left LED
Right LED
10 Mb/s
Off
Green
Port operates at 10 Mb/s. Cable connection
between the port and network device (switch, hub,
or router) is good. The port and network device are
receiving power and the NIC driver is operating
properly.
100 Mb/s
Green
Green
Port operates at 100 Mb/s. Cable connection
between the port and network device is good.
Green
Port operates at 1000 Mb/s. Cable connection
between the port and network device is good.
1000 Mb/s Red
320846-A
Status
Chapter 1 Overview
23
Table 5 Ports 3 and 4 LED status indicators (continued)
Port speed Left LED
Right LED
All speeds
Flashing
Port is sending or receiving network data. Flash
frequency varies with the amount of network
traffic.
Off
One or more above conditions is not met.
All speeds
Off
Status
Nortel Secure Network Access Switch 4050 Installation Guide
24
Chapter 1 Overview
320846-A
25
Chapter 2
Installation Process
This chapter covers the following topics:
Topic
Page
Safety precautions
25
Installing the switch in a rack
27
Installing the switch on a shelf or tabletop
27
Supplying power to the switch
28
Setting up terminal access to the switch
28
Troubleshooting installation
31
Safety precautions
Read all safety precautions before installing or servicing this device.
Caution: This device is a Class A product. In a domestic environment, this device can
cause radio interference, in which case the user may be required to take appropriate
measures. (See “Safety Message Translations” on page 39 for translations of this notice.)
Ventilation safety
The ambient temperature of an operating Nortel Secure Network Access Switch
4050 must not exceed 35ºC. When installing the device in a closed or multi-unit
rack assembly, please consider that the operating ambient temperature of the
equipment can be higher than the ambient temperature of the room. Take
appropriate steps to ensure that the device does not overheat.
Nortel Secure Network Access Switch 4050 Installation Guide
26
Chapter 2 Installation Process
For proper air circulation, the vents on the front and back of the device should not
be blocked or obstructed by cables, panels, rack frames, or other materials.
Electrical safety
Danger: Use only power cords that have a grounding path. Without a proper ground, a
person who touches the switch is in danger of receiving an electrical shock. Lack of a
grounding path to the switch may result in excessive emissions. (See “Safety Message
Translations” on page 39 for translations of this notice.)
To avoid the possibility of serious personal injury or damage to equipment due to
electrical malfunction, follow these precautions.
•
•
•
•
Circuits and wiring must support the rated power draw of the equipment.
Total rack-power load is equal to a maximum of eighty percent of the branch
circuit rating.
Power cords are free of obstructions.
Power cords at plugs, convenience receptacles, and points of exit from the
Nortel Secure Network Access Switch 4050 are carefully positioned.
Mechanical safety
Caution: When mounting this device in a rack, do not stack units directly on top of one
another in the rack. Each unit must be secured to the rack with appropriate mounting
brackets. Mounting brackets are not designed to support multiple units. (See “Safety
Message Translations” on page 39 for translations of this notice.)
For rack mounted installation, ensure that racks are stable and securely installed.
320846-A
Chapter 2 Installation Process
27
Installing the switch in a rack
Install the Nortel Secure Network Access Switch 4050 in a rack using the four
supplied rack mount screws. For rack installation, mounting brackets are shipped
attached to the front of the unit.
Follow these steps to install the unit in a rack:
1
Identify a rack location and hole spacing alignment.
2
Separately supporting the full weight of the unit, use a #2 Phillips screwdriver
to seat the four mounting screws through the front brackets and into the rack
frame.
Continue the installation process by connecting the power supply. (See
“Supplying power to the switch” on page 28.)
Installing the switch on a shelf or tabletop
Install the Nortel Secure Network Access Switch 4050 on a flat surface using the
supplied bezel adapter kit with 4 rubber feet.
Follow these steps to install the unit on a flat surface:
1
Identify a stable shelf or tabletop location.
2
Using a #2 Phillips screwdriver, remove and replace the 2 rack mount brackets
with the 2 bezel adapter kit brackets.
3
Remove the protective film from each of the supplied rubber feet and affix the
feet to the four bottom corners of the unit.
Continue by connecting the power supply. (See “Supplying power to the switch”
on page 28.)
Nortel Secure Network Access Switch 4050 Installation Guide
28
Chapter 2 Installation Process
Supplying power to the switch
Supply power after installing the unit in a rack or on a flat surface.
Note: Use of both the rear and front power switches is required for full switch operation.
Connecting the power supply
Connect the power supply using the power cord ordered for this location.
To connect the power supply, follow these steps:
1
Connect the power cord to the power receptacle on the unit’s rear panel.
2
Plug the cord into a properly fused outlet.
3
Set the rear power switch to the “|” ON position.
4
Switch the power on by pressing the power button on the front panel. The
system power LED turns green to indicate that power is being supplied.
For normal use, switch the power on. Always disconnect the power before
removing the unit from its installed location. Disconnect the power by setting the
rear panel power switch to OFF.
Setting up terminal access to the switch
The Nortel Secure Network Access Switch 4050 has a console port for system
diagnostics and configuration. This section explains how to connect a terminal to
the console port in order to establish a first console connection.
For instructions on viewing and configuring system settings using either a console
connection or network connection (via Telnet or SSH), see the Nortel Secure
Network Access Switch 4050 User Guide (320818-A).
320846-A
Chapter 2 Installation Process
29
Terminal requirements
To establish a connection with a Nortel Secure Network Access Switch 4050, the
following requirements are necessary:
•
An ASCII terminal or a computer running ASCII terminal emulation software
with the parameters shown in Table 6.
Table 6 Console configuration parameters
Parameter
Value
Baud Rate
Data Bits
Parity
Stop Bits
Flow control
9600
8
None
1
None
•
A console cable, male to female, with DB-9 connectors and 1 to 1 connections
(shipped with the Nortel Secure Network Access Switch 4050).
Console connector and pin assignments
The console port on the unit is a DCE female DB-9 connector. Table 7 describes
pin signal and I/O assignments for this connector.
Table 7 Pinouts for DB-9 console connector
DB-9 Console Port Connector
Pin
Signal
I/O
Description
1
2
3
4
5
6
7
8
9
Shell
DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS
RI
N/A
O
O
I
I
N/A
O
I
O
O
N/A
Data carrier detect
Received data
Transmitted data
Data terminal ready
Signal ground
Data set ready
Request to send
Clear to send
Ring indicator
Chassis ground
Nortel Secure Network Access Switch 4050 Installation Guide
30
Chapter 2 Installation Process
Establishing a console connection
Establish a console connection by cabling the unit to a terminal or a computer
running a terminal emulator session.
To establish a console connection, follow these steps:
1
Using the supplied console cable, connect the terminal to the console port.
2
Power on the terminal and the Nortel Secure Network Access Switch 4050.
3
To initiate the system connection process, press ENTER on the terminal.
4
At the login prompt, log in as user: admin.
5
At the password prompt, enter the administrator password. The default
administrator password is admin.
Note: To ensure continuing system security, change the default password to the password of your
choice after you successfully configure the switch.
After password verification, the system displays the Setup menu with the
information shown in Figure 6.
Figure 6 Setup menu
Alteon iSD NSNAS
Hardware platform: 4050
Software version: x.x
------------------------------------------------------[Setup Menu]
join
- Join an existing cluster
new
- Initialize host as a new installation
boot
- Boot menu
info
- Information menu
exit
- Exit [global command, always available]
>> Setup#
Continue the set-up process using instructions for initial setup in the Nortel Secure
Network Access Switch 4050 User Guide (320818-A).
320846-A
Chapter 2 Installation Process
31
Troubleshooting installation
Two situations require troubleshooting:
•
•
The system does not power on correctly.
The system powers on but shows no display text for initiating a session with
the switch.
No power
If the Nortel Secure Network Access Switch 4050 system does not power on with
LED activation and fan operation as described, perform the following checks:
•
•
•
Ensure that the power cord is connected to the Nortel Secure Network Access
Switch 4050 and connected to the AC power source.
Make sure the power source provides enough voltage and current. (See the
power supply specifications listed in Appendix A, Table 9 on page 34 for
information.)
Ensure that the power switch on the rear of the system is turned on. Press the
front panel power button.
If the system does not power on correctly after checking these items, contact
Nortel Technical Support at www.nortel.com/support.
No display text
If the system powers on and there are no boot messages or console prompt,
perform the following checks:
•
•
Ensure that the console cable is securely connected to the Nortel Secure
Network Access Switch 4050 and also to the terminal or PC running the
terminal session.
Check to make sure you have used the console cable supplied with the Nortel
Secure Network Access Switch 4050 system. (See “Terminal requirements”
on page 29 for information.)
If the system display does not function after checking these items, contact Nortel
Technical Support at www.nortel.com/support.
Nortel Secure Network Access Switch 4050 Installation Guide
32
Chapter 2 Installation Process
320846-A
33
Appendix A
Specifications
This appendix covers the following topics:
Topic
Page
Hardware and power supply specifications
33
Console port setup parameters
35
LAN connection speeds
35
Regulatory specifications
35
Hardware and power supply specifications
Table 8 lists hardware specifications for each characteristic of the switch. Table 9
lists power supply specifications for the switch.
Table 8 Hardware specifications
Characteristic
Measurement
Form Factor
1U high custom base chassis
Dimensions (H x W xD) 1.72 inches (44 millimeters) x 16.9 inches (429 millimeters) x 22 inches (559
millimeters)
Weight
approximately 25 pounds
Rack mountable
rack-mount hardware to allow mounting in 19 inch standard rack
Bezel
plastic front bezel with Nortel name/logo and Nortel SNAS 4050 model name and
number
Processor
Intel Pentium-4, 2.8 Gigahertz (GHz), 533 Megahertz (MHz) Front Side Bus (FSB)
Memory
•
•
Chipset
ServerWorks ™ GC-SL
(2) Gigabyte (GB) DDR 200/266MHz, ECC Registered
populated as (2) 1GB DIMMs or (4) 512 Megabyte (MB) DIMMs
Nortel Secure Network Access Switch 4050 Installation Guide
34
Appendix A Specifications
Table 8 Hardware specifications (continued)
Characteristic
Measurement
LAN ports
(2) 10/100/1000Base-TX (copper) ports on the motherboard
Expansion slots
(2) full-height 64-bit 133/100/66MHz PCI-X slots
PCI Card
(1) Intel Dual Port Copper 10/100/1000 Base-TX GB-E IDE PCI card
PWLA8492MT
Console port
(1) console port, DCE (DB9-F), RS-232C, 9600 Baud, 8-N-1
Pin 1, Pin 2 Transmit Data, Pin 3 Receive Data, Pin 4, Pin 5 Signal Ground, Pin 6
USB port
(2) USB 1.1 ports
Drives
(1) 40 GB or 80GB IDE hard drive, 7200 RPM, ATA133
System management
CPU temperature/voltage monitoring, fan monitoring
Light-emitting diodes
(LED)
power (green); disk-drive activity (green)
System status (amber) includes the following:
• CPU fans 1-4
• System fans
• +5V, +12V
• CPU temperature
• Motherboard ambient temperature
Power supply
300W, 100-240VAC, 50-60Hz
• Power consumption: 125W typical
• BTU: 429 BTU/hour average
Mean Time Between
Failures (MTBF)
greater than fifty thousand hours
Table 9 Power supply specifications
Power Type
Rating
AC Power Voltage
100-240 VAC 6.3 A 50-60 Hz
Current
6.3 Amperes (A)
Frequency
50-60 Hertz (Hz)
Heat
429 BTU/hour average
320846-A
Appendix A Specifications
35
Console port setup parameters
Table 10 lists console port setup parameters for the switch.
Table 10 Console port setup parameters
Parameter
Value
Baud Rate
9600
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
LAN connection speeds
Table 11 lists LAN connection speeds accommodated by the switch.
Table 11 LAN connection speeds
LAN connection speed
Connector
Medium
10Base-T
RJ-45
Cat. 3, 4, or 5 UTP
100Base-TX
RJ-45
Cat.5 UTP
1000Base-T
RJ-45
Cat.5 UTP
Regulatory specifications
Table 12 lists safety specifications. Table 13 lists emissions specifications.
Table 14 lists certification marks.
Table 12 Safety specifications
Compliance
Country
UL60950
USA
CSA22.2 No 60950
Canada
Nortel Secure Network Access Switch 4050 Installation Guide
36
Appendix A Specifications
Table 12 Safety specifications (continued)
Compliance
Country
EN60950
Europe
IEC60950
Europe
Table 13 Emissions specifications
Compliance
Country
FCC Part 15 Class A
USA
Canada ICES-003 Class A
Canada
AS/NZ 3548
Australia & New Zealand
(standard replaced by EN55022)
EN55022 (emissions) & EN55024
(immunity)
Europe
CISPR-22
Europe
VCCI
Japan
Table 14 Certification marks
320846-A
Compliance
Country
cULus
USA & Canada
CE
Europe
Gost
Russia
NOM
Mexico
S-Mark
Argentina
TUV-GS
Germany/Europe
MIC
Korea
Appendix A Specifications
37
Nortel Secure Network Access Switch 4050 Installation Guide
38
Appendix A Specifications
320846-A
39
Appendix B
Safety Message Translations
This appendix provides translations of the Caution, Danger, and Warning
messages that appear within this document.
Caution: This device is a Class A product. In a domestic environment, this device can
cause radio interference, in which case the user may be required to take appropriate
measures.
Achtung: Dieses Gerät ist ein Produkt der Klasse A. In Wohngebieten kann dieses Gerät
Funkstörungen verursachen. In diesem Fall muß der Benutzer die erforderlichen
Maßnahmen zur Beseitigung ergreifen.
Attention: Ce périphérique est un produit de classe A. Il peut provoquer des
interférences radio dans un environnement domestique;si tel est le cas, l ’utilisateur devra
prendre les mesures qui s ’imposent.
Precaución: Este dispositivo es un producto de Clase A. En un entorno doméstico, este
dispositivo puede ocasionar interferencias de radio, en cuyo caso, el usuario deberá tomar
las medidas necessarias.
Attenzione: Il dispositivo descritto nel presente documento è un prodotto di Classe A. Se
usato in ambienti domestici, può provocare interferenze radio. In tal caso, l ’utente è
tenuto a prendere provvedimenti adeguati.
Nortel Secure Network Access Switch 4050 Installation Guide
40
Appendix B Safety Message Translations
320846-A
Appendix B Safety Message Translations
41
Caution: When mounting this device in a rack, do not stack units directly on top of one
another in the rack. Each unit must be secured to the rack with appropriate mounting
brackets. Mounting brackets are not designed to support multiple units.
Achtung: Wenn diese Einheit in einem Rack montiert wird, muß ein gewisser Abstand
zur nächsten Einheit gelassen werden. Jede Einheit muß mit geeignetem
Befestigungsmaterial gesichert werden. Das Befestigungsmaterial ist nicht für die
gleichzeitige Befestigung mehrerer Einheiten geeignet.
Attention : si vous installez le module dans une baie, ne l’empilez pas directement sur
un autre. Chaque module doit être fixé à sa propre baie à l’aide des supports de montage
appropriés. Ces supports ne sont pas conçus pour résister à plusieurs modules.
Precaución: Cuando monte este dispositivo en un bastidor, no apile las unidades
directamente una encima de otra. Cada unidad debe fijarse en el bastidor con las
abrazaderas de montaje adecuadas. Las abrazaderas de montaje no están diseñadas para
sostener varias unidades.
Attenzione: se il dispositivo viene installato in un rack, non impilare le unità
direttamente una sull’altra. Ogni unità deve essere fissata al rack con le staffe di
montaggio appropriate. Le staffe di montaggio non sono state progettate per supportare
più unità.
Nortel Secure Network Access Switch 4050 Installation Guide
42
Appendix B Safety Message Translations
320846-A
Appendix B Safety Message Translations
43
Danger: Use only power cords that have a grounding path. Without a proper ground, a
person who touches the switch is in danger of receiving an electrical shock. Lack of a
grounding path to the switch may result in excessive emissions.
Vorsicht: Verwenden Sie nur Netzkabel mit Schutzerdung. Ohne ordnungsgemäße
Schutzerdung besteht für Personen, die den Switch berühren, die Gefahr eines elektrischen
Schlages. Eine nichtvorhandene Schutzerdung kann zu sehr starken Abstrahlungen führen.
Danger: n ’utilisez que des cordons d ’alimentation équipés de trajet de mise à la terre.
Sans mise à la terre adaptée, vous risquez de recevoir une décharge électrique en touchant
le commutateur. Par ailleurs, l'absence de trajet de mise à la terre peut générer des
émissions excessives.
Peligro: Utilice únicamente cables de alimentación con toma de tierra. De lo contrario, al
tocar el interruptor puede recibir una descarga eléctrica. Si no hay un circuito de toma de
tierra en el enchufe, puede producirse un exceso de emisiones.
Pericolo: Utilizzare esclusivamente cavi di alimentazione dotati di un percorso per la
messa a terra. Senza un ’adeguata messa a terra, chiunque tocchi lo switch corre il rischio
di ricevere una scossa elettrica. L ’assenza di un percorso per la messa a terra erso lo
switch può comportare un eccesso di emissioni.
Nortel Secure Network Access Switch 4050 Installation Guide
44
Appendix B Safety Message Translations
320846-A
45
Index
A
P
amber system status LED 18
pinouts for DB-9 console connector, table 29
B
port speed and status
1 and 2, table 22
3 and 4, table 22
bezel
adapter kit 17
attaching 20
removing 19
power
connecting 28
disconnecting 28
supplying to switch 28
power button 18
C
power cords 17
console cable 17
console configuration parameters, table 29
console connection, establishing 30
problems, troubleshooting installation 31
product support 12
customer support 12
R
E
rack installation 27
environmental requirements 9
F
front panel features, description 18
L
LEDs
amber system status 18
disk activity 18
front panel 18
rear panel
ports 1 and 2, table 22
ports 3 and 4, table 22
rear panel features, description 21
S
safety
electrical 26
mechanical 26
message translations 39–43
precautions 25
specifications 35
ventilation 25
shelf or tabletop installation 27
specification tables
certification marks 36
console port setup parameters 35
emissions 36
Nortel Secure Network Access Switch 4050 Installation Guide
46
Index
hardware 33
LAN connection speeds 35
power supply 34
safety 35
support, Nortel 12
system power LED 18
T
technical support 12
terminal access setup 28
text conventions 10
troubleshooting
no display text 31
no power 31
320846-A
Download PDF