SERVICE MODULE
MEDICAL OPERATIONS
(МО)
BOOK 2
MEDICAL MONITORING
SM
 РКК "ЭНЕРГИЯ", 2000
25-Sep-00
МO book 2
2E
25-Sep-00
Issue Dates and Page Revision Log
1E
2E
3E
4E
5E
6E
7E
8E
9E
10E
1-1E
1-2E
2-1E
2-2E
2-3E
2-4E
2-5E
2-6E
2-7E
2-8E
2-9E
2-10E
2-11E
2-12E
2-13E
2-14E
2-15E
2-16E
2-17E
2-18E
2-19E
2-20E
2-21E
2-22E
2-23E
2-24E
2-25E
2-26E
2-27E
2-28E
2-29E
2-30E
2-31E
2-32E
2-33E
2-34E
2-35E
2-36E
2-37E
2-38E
3-1E
3-2E
3-3E
3-4E
3-5E
3-6E
3-7E
3-8E
3-9E
3-10E
3-11E
3-12E
3-13E
3-14E
3-15E
3-16E
3-17E
3-18E
3-19E
3-20E
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-20-Oct-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
3-21E
3-22E
3-23E
3-24E
3-25E
3-26E
3-27E
3-28E
3-29E
3-30E
3-31E
3-32E
3-33E
3-34E
3-35E
3-36E
3-37E
3-38E
3-39E
3-40E
3-41E
3-42E
3-43E
3-44E
3-45E
3-46E
3-47E
3-48E
3-49E
3-50E
3-51E
3-52E
3-53E
3-54E
3-55E
3-56E
3-57E
3-58E
3-59E
3-60E
3-61E
3-62E
3-63E
3-64E
3-65E
3-66E
3-67E
3-68E
3-69E
3-70E
3-71E
3-72E
3-73E
3-74E
3-75E
3-76E
3-77E
3-78E
3-79E
3-80E
3-81E
3-82E
3-83E
3-84E
3-85E
3-86E
3-87E
3-88E
3-89E
3-90E
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
3-91E
3-92E
3-93E
3-94E
4-1E
4-2E
4-3E
4-4E
4-5E
4-6E
4-7E
4-8E
4-9E
4-10E
4-11E
4-12E
4-14E
4-15E
4-16E
4-17E
4-18E
4-19E
4-20E
4-21E
4-22E
4-23E
4-24E
5-1E
5-2E
5-3E
5-4E
5-5E
5-6E
5-7E
5-8E
5-9E
5-10E
5-11E
5-12E
5-13E
5-14E
5-15E
5-16E
5-17E
5-18E
5-19E
5-20E
5-21E
5-22E
5-23E
5-24E
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
-25-Sep-00
МO book 2
3E
25-Sep-00
TABLE OF CONTENTS
1.
GENERAL INSTRUCTIONS................................................................................................... 1-1
1.1.
1.2.
2.
CREW RESPONSIBILITIES ............................................................................................................1-1
CREW PROCEDURES WORKING SEQUENCE .............................................................................1-1
COUNTERMEASURES .......................................................................................................... 2-1
2.1. TRAINING ON CYCLE ERGOMETER .............................................................................................2-2
2.1.1. OPERATION SEQUENCE ..........................................................................................................2-2
2.2. MYOELECTROSTIMULATION ......................................................................................................2-10
2.2.1. MYOELECTROSTIMULATION IN ACUTE PERIOD..................................................................2-10
2.2.2. MYOELECTROSTIMULAITON COMBINED WITH PHYSICAL EXERCISES.............................2-11
2.3. TRAINING USING CHIBIS.............................................................................................................2-13
2.3.1. SETUP FOR OPERATION........................................................................................................2-15
2.3.2. MCC CONTROLLED OPERATION ...........................................................................................2-18
2.3.3. CLOSEOUT OPERATIONS ......................................................................................................2-19
2.4.
RANDOM MUSCULAR EXERTION (ПМН) ....................................................................................2-21
2.5. TVIS TREADMILL EXERCISE .......................................................................................................2-22
2.5.1. EXERCISE PREPARATION......................................................................................................2-22
2.5.1.1. SUBJECT'S POSITION ON TVIS ....................................................................................2-24
2.5.2. THREE-DAY CYCLE TRAINING USING TVIS ..........................................................................2-25
2.5.2.1. MANUAL CONTROL MODE ...........................................................................................2-31
2.5.2.2. ACTIVATION MOVEMENT MODE..................................................................................2-32
2.5.2.3. ACTIVATION NO LOAD MODE ......................................................................................2-33
2.5.3. EXERCISE WITH PRE-PROGRAMMED PROTOCOL ..............................................................2-34
2.5.4. CLOSEOUT ..............................................................................................................................2-35
2.5.5. OFF-NOMINAL SITUATIONS ...................................................................................................2-37
3.
HEALTH MONITORING ......................................................................................................... 3-1
3.1. BP MEASUREMENT WITH SPHYGMOMANOMETER TENSOPLUS ..............................................3-1
3.1.1. SETUP .......................................................................................................................................3-1
3.1.2. BLOOD PRESSURE MEASUREMENT.......................................................................................3-2
3.2. MO-1 INVESTIGATING HEART BIOELECTRICAL ACTIVITY AT REST .........................................3-7
3.2.1. INITIAL SETUP.........................................................................................................................3-10
3.2.2. MCC CONTROLLED OPERATION ...........................................................................................3-12
3.2.3. CLOSEOUT OPERATIONS ......................................................................................................3-12
3.3. MO-2 ECG 24-HOUR RECORDING ..............................................................................................3-13
3.3.1. SETUP FOR OPERATION........................................................................................................3-13
3.3.2. ELECTRODES INSTALLATION AND ECG RECORDING.........................................................3-14
3.3.3. CLOSEOUT OPERATIONS ......................................................................................................3-15
3.4. МО-4 ORTHOSTATIC STABILITY EVALUATION WITH LBNP ......................................................3-16
3.4.1. INITIAL SETUP.........................................................................................................................3-18
3.4.2. MCC CONTROLLED OPERATION ...........................................................................................3-22
3.4.3. CLOSEOUT OPERATIONS ......................................................................................................3-23
3.5.
МО-5 CARDIOVASCULAR EVALUATION DURING GRADED EXERCISES ON CYCLE
ERGOMETER.....................................................................................................................3-25
3.5.1. INITIAL SETUP.........................................................................................................................3-27
3.5.2. MCC CONTROLLED OPERATION ...........................................................................................3-30
3.5.3. CLOSEOUT OPERATIONS ......................................................................................................3-31
МO book 2
4E
25-Sep-00
3.6. МО-6 HAND CYCLE ERGOMETRY ................................................................................................. 3-33
3.6.1. INITIAL SETUP.............................................................................................................................. 3-34
3.6.2. MCC CONTROLLED OPERATION............................................................................................... 3-35
3.6.3. CLOSEOUT OPERATIONS .......................................................................................................... 3-36
3.7.
МО-7 MEASURING CALF VOLUME (ИЗОГ)................................................................................... 3-37
3.8. МО-8 BODY MASS MEASUREMENT ............................................................................................. 3-42
3.8.1. SETUP FOR BODY MASS MEASUREMENT (ИМТ MODE) ....................................................... 3-42
3.8.2. BODY MASS MEASUREMENT .................................................................................................... 3-45
3.8.3. CLOSEOUT OPERATIONS FOR ИМТ MODE OPERATIONS .................................................... 3-48
3.9. МО-9 BIOCHEMICAL URINE TEST................................................................................................... 3-53
3.9.1. UROLUX UNIT SETUP ................................................................................................................. 3-53
3.9.2. CHOOSING MEASURING UNITS................................................................................................. 3-54
3.9.3. UNIT CALIBRATION ..................................................................................................................... 3-54
3.9.4. URINE TEST.................................................................................................................................. 3-56
3.9.5. CLOSEOUT OPERATIONS .......................................................................................................... 3-57
3.9.6. MEASURING CHANNEL CHECK ................................................................................................. 3-58
3.9.7. MEASURING STRIP VISUAL EVALUATION................................................................................ 3-59
3.9.8. TROUBLESHOOTING................................................................................................................... 3-61
3.10. МО-10 DETERMINING HEMATOCRIT NUMBER ........................................................................... 3-65
3.10.1. MEASURING HEMATOCRIT NUMBER ..................................................................................... 3-65
3.10.2. REPLACING MINICENTRIFUGE BATTERY SET...................................................................... 3-68
3.11. МО-11 BIOCHEMICAL BLOOD ANALYSIS..................................................................................... 3-73
3.11.1. INITIAL SETUP ........................................................................................................................... 3-73
3.11.1.1. DEVICE FUNCTIONAL CHECK ......................................................................................... 3-75
3.11.2. MULTIPLE-PARAMETER TEST................................................................................................. 3-78
3.11.3. ONE-PARAMETER-TEST OPERATION .................................................................................... 3-85
3.11.4. CLOSEOUT OPERATIONS........................................................................................................ 3-85
3.11.5. MEASURING CHAMBER CLEANUP ......................................................................................... 3-86
3.11.6. LIST OF READOUT MESSAGES AND TROUBLESHOOTING................................................. 3-88
4.
CONTROL OF ENVIRONMENT ............................................................................................. 4-1
4.1. МО-21 CONTROL OF ENVIRONMENT MICROECOSPHERA......................................................... 4-1
4.1.1. SETUP ............................................................................................................................................. 4-2
4.1.1.1. CHARGING БП ЭКОСФЕРА (ECOSPHERA BATTERY) .................................................... 4-2
4.1.2. TEST PERFORMANCE................................................................................................................... 4-3
4.1.2.1. HARDWARE ACTIVATION ................................................................................................... 4-3
4.1.1.2. MICROFLORA SAMPLE COLLECTION............................................................................... 4-4
4.1.1.3. CLOSEOUT OPERATIONS .................................................................................................. 4-6
4.1.1.4. EVALUATION OF TEST RESULTS...................................................................................... 4-7
4.1.1.5. TOTAL COLONY COUNT ..................................................................................................... 4-7
4.1.1.6. COLONY CLASSIFICATION IN PETRI DISHES WITH MEDIA 1 ........................................ 4-8
4.1.1.7. COLONY CLASSIFICATION IN PETRI DISHES WITH MEDIUM 2 ..................................... 4-8
4.1.1.8. DOWNLINK INFORMATION................................................................................................. 4-8
4.2.
МО-22 SANITARY-EPIDEMIOLOGICAL STATUS MONITORING ................................................. 4-24
МO book 2
5.
5E
25-Sep-00
QUESTIONARY...................................................................................................................... 5-1
5.1.
5.2.
5.3.
PHS (30 DAY PHYSICAL EVALUATION) ............................................................................................ 5-1
PRE-EVA EXAMS............................................................................................................................... 5-13
POST-EVA EXAMS ............................................................................................................................ 5-17
МO book 2
6E
For notes
25-Sep-00
МO book 2
7E
For notes
25-Sep-00
МO book 2
8E
ACRONYMS AND ABBREVIATIONS
АД
- arterial blood pressure
Б/И
БП
- crew procedure
- power supply unit
ВАП
ВБ
ВКЛ
ВПГ
ВЫКЛ
- venous-arterial pulsogram
- cycle ergometer
- activate
- temporal pulsogram
- deactivate
ГИ
- impulse generator
ЗАКР
- close, to close
ИМ
ИМТ
- mass measurement device
- body mass measurement
ККГ
- kynetocardiogram
ОДНТ
ОТКЛ
ОТКР
- lower body negative pressure, LBNP
- deactivate
- open, opened
ПИТ
ПВК
ПКО
ПМО
ППС
ПУ
- power
- LBNP prophylactic system
- biomed harness
- medical exam panel
- systems power panel
- control panel
РБС
РМ
РПГ
РЭГ
- onboard power outlet
- workstation
- rheogram
- rheoencephalogram
25-Sep-00
МO book 2
9E
СЛГ
- personal hygiene articles
ТНК
- training-loading suit
УСИ
УС
УСВ
- sensor unit
- Matching Unit
- MASS MEASUREMENT PANEL
ЦИ
- digital indicator
ЧСС
ЧП
- heart rate
- pulse rate
ШКО
- biomed cap
ЭКГ
- electrocardiogram, ECG
ДнаЗ
ДпоУЗ
- Report to MCC
- √MCC
кан
кн
кбл
клав
- channel
- pushbutton, pb
- cable
- pushbutton, pb
max
- highest value, maximum
п
пан
перекл
поРЭ
поУЗ
- section
- panel
- switch, sw
- crew preference
- on MCC GO
рзм
р/г
Рис
- connector
- radiogram
- figure
СвД
с/с
стр
сх
- led
- comm pass
- page
- schematic, diagram
Табл
- Table
25-Sep-00
МO book 2
!
"
#
$
%
&
'
(
→
)
*
↑
↓
10E
25-Sep-00
- illuminated
- not illuminated
- blinking
- illumination status changes when command is issued
- rotate clockwise
- rotate counterclockwise
- rotate clockwise to stop
- rotate counterclockwise to stop
- place physical device in designated state
- connect
- disconnect
- up(wards)
- down(wards)
+
,
.
/
0
1
- sw → On (i.e. up relative to label on panel)
- sw → Off (i.e. down relative to label on panel)
- press pushbutton
- press pushbutton to lock
- press pushbutton to release
- verify
- verify aurally
√
- check (in case of discrepancy, attempt a corrective action one time
only)
12:35:20
00:30:00
00:00:10
00:35:20
03:00:00
00:05:00
00:00:08
Р
- hr, min, sec
- min
- sec
- min, sec
- hr
- min
- sec
- pressure
Т.0
- AOS time
Т.КТМ
- LOS time
********** - an anticipated off-nominal situation, if the condition left of the asterisks
***************
on the same line is not met, perform action(s) enclosed by asterisk
lines
***************
********** Sect. 5 - an anticipated off-nominal situation, if the condition left of the asterisks
on the same line is not met, proceed per indicated reference
********** √MCC
- an unanticipated off-nominal situation, if the condition left of the
asterisks on the same line is not met, halt procedure execution and
√ MCC
MO book 2
General Instructions
1-1E
25-Sep-00
1. GENERAL INSTRUCTIONS
These Medical Operations crew procedures are intended for trained crew members who
have completed the full training course and simulations
These crew procedures may be updated pending systems modifications and procedure
validation sessions
1.1. CREW RESPONSIBILITIES
While performing operations, the crew is responsible for the following actions:
Perform operations per these crew procedures
! systems and equipment operation
Report to MCC completed operations and performance of systems and equipment
In the event of system or instrument malfunction, crew is responsible for the following
actions:
power down the failed hardware (if necessary)
record the time when the deviation (malfunction) was detected
record the nature of the deviation (malfunction)
Report to MCC
1.2. CREW PROCEDURES WORKING SEQUENCE
Obtain source data from MCC
! sufficiency of the received data
Schedule a command output sequence (if necessary)
Perform setup steps
Perform the indicated actions, while monitoring systems operation
Perform closeout steps
Measurement results should be entered into Laptop or recorded in corresponding tables
provided in the crew procedures
Prepare a report:
on completion of tasks
on any detected peculiarities or deviations (with a time stamp)
MO book 2
General Instructions
1-2E
For notes
25-Sep-00
МO book 2
Countermeasures
2-1E
25-Sep-00
2. COUNTERMEASURES
The following countermeasures are used for prevention of the negative effect of microgravity:
1.
Physical training on Treadmill and Cycle Ergometer; also, physical exercises using
Chest Expander (see MO Book 1 Sect. 5.5 p.5-21) and Training-Loading Suit (see
MO Book 1 Sect. 5.3 p.5-9)
2.
Myoelectrostimulation
3.
LBNP training in the Chibis suit
4.
Random muscular exertions
5.
Use of Penguin-3 suit (see MO Book 1 Sect. 5.2 p.5-5), Kentavr suit (see MO
Book 1 Sect. 5.8 p.5-31), Braslet cuff (see MO Book 1 Sect. 5.1 p.5-1)
6.
Use of pharmaceuticals
МO book 2
Countermeasures
2-2E
25-Sep-00
2.1. TRAINING ON CYCLE ERGOMETER
2.1.1. OPERATION SEQUENCE
PRIOR TO TRAINING:
1.
Install cycle ergometer to working configuration (see МО Book 1 Sect.5.4.1
p. 5-15 – 5-17)
2.
Don sports clothes and shoes
3.
Temp stow chest expanders in cycle ergometer area
4.
Adjust generator assembly and seat positions:
Pull fixer latch sleeve on the required rod in the arrow direction
Adjust generator assembly or seat position as convenient
Release fixer latch sleeve
Move generator assembly or seat position until captured (wait for audible click)
FOOT PEDALING MODE:
5.
Get into cycle ergometer seat
Put feet in pedal toe clips
Secure with belts
6.
Use Cycle Ergometer per PHYSICAL TRAINING procedure (see Figure 2.1 Figure 2.3 pp. 2-3 - 2-5)
ARM PEDALING MODE:
7.
Remove pedals by pressing on fixer latch
Stow pedals in pocket on seat cover
Use Cycle Ergometer per PHYSICAL TRAINING procedure (see Figure 2.1 Figure 2.3 pp.2-3 - 2-5)
AFTER TRAINING:
8.
Unfasten belts
Remove feet from toe clips
Leave cycle ergometer
Record current training results in log sheet (see p. 2-7)
9.
10.
Stow chest expanders
Doff sports clothes and shoes in order to be dried
Stow cycle ergometer under panel 121 (see МО Book 1 Sect. 5.4.3 p.5-18)
Perform hygiene routines
МO book 2
Countermeasures
2-3E
Figure 2.1
25-Sep-00
МO book 2
Countermeasures
2-4E
Figure 2.2
25-Sep-00
МO book 2
Countermeasures
2-5E
Figure 2.3
25-Sep-00
МO book 2
Countermeasures
2-6E
For notes
25-Sep-00
МO book 2
Countermeasures
2-7E
25-Sep-00
Log Sheet
Date
Name
Total Work
Total Training
Time
МO book 2
Countermeasures
2-8E
25-Sep-00
Log Sheet
Date
Name
Total Work
Total Training
Time
МO book 2
Countermeasures
2-9E
For notes
25-Sep-00
МO book 2
Countermeasures
2-10E
25-Sep-00
2.2. MYOELECTROSTIMULATION
2.2.1. MYOELECTROSTIMULATION IN ACUTE PERIOD
1.
! TONUS MED SYS
2.
Secure Subject next to Tonus equipment
3.
Apply electrodes to thigh and trapezoid muscles (see diagram
on the equipment)
<TONUS>
IMPULSE
GENERATOR
4.
connector Ш1 of cable 2 " connector OUTPUT
connector of cable 2 " trapezoid electrodes connectors
per decal
<TONUS>
IMPULSE
GENERATOR
5.
Move knobs 1- 6 (all) to leftmost position
sw OPERATIONAL MODE →
(rapid contractions)
sw PROGRAM → IV
! PWR
6.
Gradually turn knobs 4 and 5 to the right until pronounced
muscle contractions will occur
Stimulate muscles for 10 min
7.
When muscles become adapted and stop contracting, gradually
turn knobs 4 and 5 more to the right until pronounced muscle
contractions will reappear
8.
Continue stimulation of trapezoid muscles for 5-10 min
ППС-24
NOTE
In the event of unpleasant sensations under the electrodes or if there are no
stimulated muscle contractions, turn knobs 4 and 5 to the extreme left and
wait for 20 min, or moisten electrodes with conductive fluid from GAMMA-1 set,
then resume stimulation
<TONUS>
IMPULSE
GENERATOR
9.
knobs 4 and 5 → leftmost position
# PWR
cable 2 $ connector OUTPUT
connector INPUT4 of cable 4 " connector OUTPUT4 of cable 3
cable 3 " connector OUTPUT
10.
connector ГОЛЕНЬ ЛЕВАЯ (left shin) of cable 4 " connector of
electrodes БЕДРO ЛЕВОЕ (left thigh)
connector ГОЛЕНЬ ПРАВАЯ (right shin) of cable 4 " connector
of electrodes БЕДРО ПРАВОЕ (right thigh)
МO book 2
Countermeasures
<TONUS>
IMPULSE
GENERATOR
ППС-24
2-11E
25-Sep-00
11.
sw PROGRAM → III
! PWR
12.
Gradually turn knobs 2, 3, 5, 6 to the right until pronounced
muscle contractions will occur
Stimulate muscles for 10-15 min
13.
knobs 2, 3, 5, 6 → leftmost position
# PWR
cbl 3 + 4 $electrodes and <TONUS> IMPULSE GENERATOR
Stow cables and electrodes in bag
14.
# TONUS MED SYS
2.2.2. MYOELECTROSTIMULAITON COMBINED WITH PHYSICAL EXERCISES
(to be performed on the active rest day)
ППС-24
<TONUS>
IMPULSE
GENERATOR
1.
! TONUS MED SYS
2.
Secure Subject next to Tonus equipment
3.
Apply back-abdomen, thigh, shin electrodes (see diagram on
the equipment)
4.
cbl 3+4 " cnctr OUTPUT on <TONUS> IMPULSE
GENERATOR
cnctr of cbl 4 " cnctr of electrodes per decal
5.
Move knobs 1- 6 (all) to leftmost position
sw OPERATIONAL MODE →
(rapid contractions)
sw PROGRAM → III
6.
! PWR
Gradually turn knobs 1, 2, 3, 4, 5, 6 to the right until pronounced
muscle contractions will occur
Stimulate muscles for 2 min
7.
sw OPERATIONAL MODE →
Stimulate for 2 min
8.
sw OPERATIONAL MODE →
Stimulate for 2 min
(slow contractions)
(rapid contractions)
МO book 2
Countermeasures
<TONUS>
IMPULSE
GENERATOR
9.
10.
2-12E
25-Sep-00
knobs 1- 6 (all) → leftmost position
connectors ГОЛЕНЬ ЛЕВАЯ (left shin) and ГОЛЕНЬ ПРАВАЯ
(right shin) of cable 4 $ connectors of shin electrodes
connector ГОЛЕНЬ ЛЕВАЯ (left shin) and ГОЛЕНЬ ПРАВАЯ
(right shin) of cable 4 " connectors of electrodes БЕДРO
ЛЕВОЕ (left thigh) and БЕДРО ПРАВОЕ (right thigh),
respectively
<TONUS>
IMPULSE
GENERATOR
ППС-24
11.
Gradually turn knobs 2, 3, 5, 6 to the right until pronounced
muscle contractions will occur
Stimulate for 4 min
12.
knobs 2, 3, 5, 6 → leftmost position
# PWR
cbl 3+4 $ electrtodes and <TONUS> IMPULSE GENERATOR
Stow all cables and electrodes in bag
13.
# TONUS MED SYS
МO book 2
Countermeasures
2-13E
2.3. TRAINING USING CHIBIS
Hardware:
Gamma-1 equipment
РПГ КОММУТАТОР (Switching unit)
LBNP Chibis
УСИ ВАП-ККГ sensors
УСИ РЭГ-1 sensors
УСИ АД sensors
ГАММА-1 set
Wet wipes
Dry wipes
Figure 2.4 Subject Outfitting Diagram
25-Sep-00
МO book 2
Countermeasures
2-14E
Figure 2.5 Reference Physiological Curves
25-Sep-00
МO book 2
Countermeasures
2-15E
25-Sep-00
1.
Unstow required hardware
2.
connector OUTPUT of cable 5А4.856.922 " connector OUTPUT
on РПГ КОММУТАТОР side panel
connectors INPUT I, INPUT II of cable 5А4.856.922 " connectors INPUT I, INPUT II
on RHEOPLETHYSMOGRAPHY PANEL (GAMMA-1)
3.
Temp stow РПГ КОММУТАТОР
2.3.1. SETUP FOR OPERATION
(00:20:00)
NOTE
Assistant helps Subject with outfitting
1.
Unstow ПКО ЭКГ-ККГ biomed harness belt from УСИ ВАП-ККГ
bag
2.
Moisten electrode pads of ЭКГ-ККГ belt using conductive fluid
from ГАММА-1 set
3.
Don ЭКГ-ККГ belt at 5th intercostal level (see Figure 2.4 p. 2-13)
Adjust belt and straps to desired length, engaging hooks into
required loops, maintaining symmetry relative to backbone
4.
Turn belt down to expose electrode application sites
Treat skin in electrode application areas using wet wipe
Apply electrodes to the body
√ correct placement (see Figure 2.4 p. 2-13) and good contact of
ЭКГ-DS with Subject’s skin
% ECG electrodes conform to corresponding “D”, “S”, “O” labels
on biomed harness belt
5.
Remove cover from Chibis suit
Remove shackle strap from Chibis suit
Unstow hose harness from kit
√ hose harness " cnctrs on Chibis suit, <CHIBIS> SUIT
PRESSURE CONTROL
6.
Get into Chibis suit
Pull Chibis suit drum up to the waistline
Don Chibis suit shoulder straps
Assist Subject with
outfitting
МO book 2
Countermeasures
2-16E
25-Sep-00
7.
connector ПКО ЭКГ-ККГ " connector EKG HARNESS on
MEDICAL EXAM PANEL
8.
Unstow ШКО РЭГ-1 biomed cap (of a required size) from УСИ РЭГ-1
bag
9.
√ numbers on electrodes match labels on ШКО РЭГ-1
Moisten ШКО РЭГ-1 electrode pads using conductive fluid from
GAMMA-1 set
CAUTION
Do not allow hair get under the electrodes
10.
Don ШКО РЭГ-1 biomed cap on the head (label 'ЛОБ' should be on
the forehead)
Turn down biomed cap straps
Clean skin in РЭГ electrode application sites using wet wipe
Brush hair aside and apply electrodes to the skin
11.
√ correct placement of electrodes (see Figure 2.4 p. 2-13):
3, 4 and 7, 8 – on mastoid processes (behind ears) of temporal
bones on the left and right sides
1, 5 and 2, 6 – on the right and left sides of the forehead
12.
connector INPUT I РЭГ on ШКО РЭГ-1 " connector РЭГ (INPUT I)
of РПГ КОММУТАТОР (on the left)
connector INPUT II РЭГ on ШКО РЭГ-1 " connector РЭГ (INPUT II)
of РПГ КОММУТАТОР (on the right)
13.
Unstow blood pressure cuff from УСИ АД bag
14.
Secure blood pressure cuff on the left arm, the sensor must be 2 cm
above elbow crease from inside of arm
15.
cuff hose " connector CUFF on BLOOD PRESSURE PANEL
cuff cable " connector PRESSURE-SOUND
on BLOOD PRESSURE PANEL
16.
On BLOOD PRESSURE PANEL:
sw OPERATIONAL MODE → PRESSURE WAVE FORM
sw MODE → AUTO
sw mm Hg → 180
17.
! <GAMMA> MED SYS on ППС-24
! CHIBIS MED SYS on ППС-24
МO book 2
Countermeasures
2-17E
25-Sep-00
18.
! PANEL PWR on MEDICAL EXAM PANEL
& PANEL PWR on MEDICAL EXAM PANEL
& upper LED on BLOOD PRESSURE PANEL
& LED on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>
19.
sw OPERATIONAL MODES on MEDICAL EXAM PANEL → OSC
20.
On OSCILLOSCOPE:
sw OPERATIONAL MODES → SWEEP
pb BRIGHTNESS → the middle position
pb SWEEP VELOCITY→ the middle position
21.
On РПГ КОММУТАТОР:
left sw PROGRAM → 2
right sw PROGRAM → OFF
22.
Set signal amplitude:
sw GAIN II on MEDICAL EXAM PANEL → 5
GAIN on BLOOD PRESSURE PANEL → 3
sw GAIN I on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>
RO → 3
ΔR → 4
23.
% presence and proper waveform of signals (see Figure 2.5 p. 2-14),
sequentially toggle on MEDICAL EXAM PANEL:
sw OSCILLOSCOPE → II (ЭКГ-DS)
sw OSCILLOSCOPE → III (dR/dt)
sw OSCILLOSCOPE → IV (РЭГ (ΔR and RO sequentially))
24.
' START on BLOOD PRESSURE PANEL
25.
% presence and proper waveform of signals (see Figure 2.5 p. 2-14),
sequentially toggle on MEDICAL EXAM PANEL:
sw OSCILLOSCOPE → V (АД-ТО)
sw OSCILLOSCOPE → VI (ОД)
26.
Tighten Chibis waist belt (belt pad of removable waste seal curtain should
be in the small of the back)
NOTE
Gain settings for all recorded physiological curves may be changed
on MCC GO
МO book 2
Countermeasures
2-18E
25-Sep-00
2.3.2. MCC CONTROLLED OPERATION
(Telemetry Session)
NOTE
Chibis training sequence is shown in Table 2.1 p.2-20
On MCC GO
1.
Т.0
2.
Relax during blood pressure
measurement
3.
Move lower part of the legs to
simulate walking during the
remainder of the session
4.
On MEDICAL EXAM PANEL:
sw OPERATIONAL MODES → TLM GAIN
After 10 sec, sw OPERATIONAL MODES → OSC
5.
' START on BLOOD PRESSURE PANEL
6.
sw on <CHIBIS> SUIT PRESSURE CONTROL →
AUTO VACUUM
LED on <CHIBIS> SUIT PRESSURE CONTROL
W ARNING
To quickly return to ambient pressure in an emergency, loosen
Chibis suit waist belt and break seal around body
√ MCC to adjust VACUUM (negative pressure) knob
position.
7.
8.
9.
Т.КТМ (end of session)
sw on <CHIBIS> SUIT PRESSURE CONTROL → OFF
( LED on <CHIBIS> SUIT PRESSURE CONTROL
МO book 2
Countermeasures
2-19E
25-Sep-00
2.3.3. CLOSEOUT OPERATIONS
(00:15:00)
1.
# PANEL PWR on MEDICAL EXAM PANEL
( LED PANEL PWR on MEDICAL EXAM PANEL
( upper LED on BLOOD PRESSURE PANEL
( LED on RHEOPLETHYSMOGRAPHY PANEL
<GAMMA-1>
2.
cnctr ПКО ЭКГ-ККГ, ШКО РЭГ-1,
blood pressure cuff $ cnctrs of ГАММА-1М
3.
# <GAMMA> MED SYS on ППС-24
# CHIBIS MED SYS on ППС-24
4.
Doff Chibis suit
5.
Doff ПКО ЭКГ-ККГ, ШКО РЭГ-1,
blood pressure cuff
hose harness $ Chibis suit
Dry out ПКО ЭКГ-ККГ, ШКО РЭГ-1
6.
Wipe inside surface of Chibis suit waist
seal curtain using wipe
Dry out Chibis suit for 30-60 min using
air blowing from airduct outlets
7.
Fold Chibis suit
Reinstall shackle strap
Stow air hoses
Install cover on Chibis suit
Stow Chibis suit
Stow ПКО ЭКГ-ККГ, ШКО РЭГ-1, and
blood pressure cuff
МO book 2
Countermeasures
2-20E
25-Sep-00
Table 2.1 Chibis Suit Training Diagram
BLOOD PRESSURE PANEL:
sw MODE → AUTO
OPERATIONAL MODES → PRESSURE WAVE FORM
Mm Hg → 180
on MCC GO: ' START on BLOOD PRESSURE PANEL
RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1> and РПГ КОММУТАТОР:
ШКО РЭГ-1 " РПГ КОММУТАТОР
right sw PROGRAM of РПГ КОММУТАТОР → OFF
left sw PROGRAM of РПГ КОММУТАТОР → 2
Impact modes
Impact time
Preliminary training sessions
day 1
10, 15, 20, 25 mm Hg
5 min
day 2
15, 20, 25, 30 mm Hg
5 min
day 3
20, 25, 30, 35 mm Hg
5 min
day 4
25, 30, 35, 40 mm Hg
5 min
day 5
25, 35, 40, 45 mm Hg
5 min
day 6
25, 35, 40, 45 mm Hg
5 min
When each training session is complete
gradual decrease (for 1 min) up to 0
Final training sessions (two days)
1 cycle
25, 35, 40, 45 mm Hg
5 min
Gradual decrease (for 1 min) up to 0
2 cycle
25, 35, 45 mm Hg
10 min
30 mm Hg
5 min
Gradual decrease (for 1 min) up to 0
МO book 2
Countermeasures
2-21E
25-Sep-00
2.4. RANDOM MUSCULAR EXERTION (ПМН)
Perform ПМН per indication of Flight Surgeon over the first 1-5 days in the period
of acute adaptation to microgravity and when experiencing vestibular autonomic
discomfort
At the first signs of discomfort:
Avoid jerky movements of head and eyes
Sit in seatliner or Cycle Ergometer seat
Press spine and back of your head firmly against the support, with arms on the
arm rests
Close eyes or focus them on a non-moving object
Take 3-5 deep, well-controlled breaths slowly exhaling each time
If there is no improvement, perform ПМН:
Flex leg muscles, increasing exertion level to a max over 3-4 sec and hold for 510 sec
Relaxing leg muscles, flex arm and chest muscles following the same pattern
Relaxing arms, contract extensors of the trunk and neck, followed by the
flexion of abdomen muscles
Breath in any convenient manner, as exertion increases - inhale deeper
Repeat exercises continuously 3-4 times (breathe without using diaphragm when
flexing the abdomen muscles)
МO book 2
Countermeasures
2-22E
20-Oct-00
2.5. TVIS TREADMILL EXERCISE
Hardware:
TVIS
TVIS exercise suit
Accessory kits
2.5.1. EXERCISE PREPARATION
HRM kit
1. Unstow (HRM) chest strap and HRM transmitter
Don (HRM) chest strap
Install HRM transmitter
2. Don training underwear, footwear
3. √ TVIS Cntl Pnl secured near TVIS and ready for operation
Exercise kit
4. Unstow individual ССМ card
Secure (CCM card) near TVIS Cntl Pnl
NOTE
Text messages (underlined font) specified below shall be monitored on
MAIN MENU/MESSAGE LCD screen, if other LCD is not specified
pnl 435,
БВП - 20
БВП - 20
TVIS Cntl Pnl
TVIS Cntl Pnl
(top)
5. SYSTEM ACTIVATION
H ON (left)
H ON (right)
" LED SYS PWR
6. G SYS PWR
" LED
" all LCDs
" INSERT CCM
" LED MOTOR TRD
**********
" LED PWR TRD
**********
" LED GYRO VIS
**********
" LED STBL VIS
**********
***********************************************************
Lift switch protective cover
G respective pb above LED
If $ LED - per MCC instructions
************************************************************
NOTE
To return to previous menu or to clear erroneous command input, G CLR
МO book 2
Countermeasures
2-23E
7. G ENT
" UNIT SELECTION
% UNKNOWN SUBJECT
G 1(2) to select English or Metric units (miles, pounds
(kilometers, kilograms))
G ENT
" VIS STATUS MENU
TVIS Cntl Pnl
(top)
8. G GIRO VIS
G STBL VIS
" LED
" LED
NOTE
1. VIS STATUS MENU will be indicating gyro underspeed status, at the
same time its speed will be increasing
2. All stabilizers (four) will be reporting errors until gyro speed reaches
2000 rpm
3. Gyro spin-up time - 5---10 minutes
Exercise kit
TVIS Cntl Pnl
9. DONNING TVIS EXERCISE SUIT
Unstow TVIS suit
Unfasten two waist strap buckles (blue)
Unfasten Velcro strap
Insert arms into harness straps
Fasten chest strap buckle (orange),
adjust strap length if necessary
Fasten Velcro strap
Fasten two waist strap buckles (blue)
Tighten two front straps (blue) of waist belt
Tighten two back straps (yellow) of waist belt
Tighten two front shoulder straps (green)
Tighten two back shoulder straps (purple)
10. & GYRO SPEED 2300 ± 150
G SYSTEM PAUSE
" SYSTEM PAUSED
11. G 7 (to stop system work cycle)
& digit 7 appears in the screen upper row
G ENT
" FOR FINAL SUBJECT LOAD
G ENT
" EXERCISE COMPLETE
" INSERT CCM
$ BELT SPEED
$ HEART RATE
$ DISTANCE
$ ELAPSED TIME
$ EXERCISE PROFILE
System is ready for the first subject
20-Oct-00
МO book 2
Countermeasures
2-24E
20-Oct-00
2.5.1.1. SUBJECT'S POSITION ON TVIS
1. Unstow bungees from exercise kit
Bungees ' to right and left D-rings on TVIS suit waist strap, located
closest to centerline of thigh
TVIS
2. Side brackets → Vertical position
Tighten knurled knobs (two)
3. Stand on TVIS side running boards, placing feet
between Series Bungee System
Bungees ' to Series Bungee System D-rings
(if necessary, adjust length using clevises)
4. Side brackets clevises ' to same D-rings
on waist strap of TVIS suit as with bungees
TVIS Cntl
Pnl
5. Lift left top cover of TVIS Cntl Pnl
Insert CCM card in the slot, placing the marked side of card to Cntl Pnl
rear panel.
" UNIT SELECTION
% Card owner info
6. G 1(2) to select English or Metric units (miles, pounds (kilometers,
kilograms))
G ENT
" PROTOCOL SELECTION MENU
7. Select operation mode (see Sect 2.5.2.1 page 2-31 or
Sect 2.5.3 page 2-34) - per MCC instructions
МO book 2
Countermeasures
2-25E
20-Oct-00
2.5.2. THREE-DAY CYCLE TRAINING USING TVIS
1.
Per MCC instructions perform exercises according to physical training procedures
(see Table 2.3 page 2-28, Table 2.4 page 2-29, Table 2.5 page 2-30)
Exercises are described in Table 2.2
2.
Upon exercise completion
G SYSTEM PAUSE
" SYSTEM PAUSED
3.
Perform closeout operations Sect 2.5.4 page 2-35
NOTE
To stop TVIS belt tighten belt resistance switch
until stop
PHYSICAL EXERCISES ON TVIS
Table 2.2
Exer
cise
No.
1.
2.
Exercise description
Exercise preparation
Walking: ordinary steps, on toes, on heels, on outer and
inner sides of foot (Speed = 4.5 --- 5 km/h, T= 2 min)
3.
Medium pace running (Speed = 6.5---7 km/h, Т= 2 мин)
4.
Breathing exercises with movements of arms 4 --- 5 times
5.
8.
Semi-squats with "load"
Initial position  main stance, middle of long bungee
behind shoulders, toes inside loops, 15---20 times
Press with one arm up, aside, short bungee, 12 --- 15
times, quick pace
Same with the other arm
Pelvis round movements
Initial position — main stance, arms on waist
4 --- 5 times to right and left
Walking (Speed = 4.5---5 km/h, Т= 2 min)
9.
Medium pace running (Speed = 6.5---7 km/hr, Т= 2 min)
6.
7.
TVIS mode
Magnet → EMERGENCY
STOP
No-load
Magnet → EMERGENCY
STOP
No-load
Magnet ← EMERGENCY
STOP
Belt stop
Magnet ← EMERGENCY
STOP
Belt stop
Magnet ← EMERGENCY
STOP
Belt stop
Magnet ← EMERGENCY
STOP
Belt stop
Magnet → EMERGENCY
STOP
No-load
Magnet → EMERGENCY
STOP
No-load
МO book 2
Countermeasures
2-26E
Table 2.2 (continued)
10. Press from chest.
Initial position — main stance, bungee behind back,
First day: 12 --- 15 times, quick pace (1 time per 1 sec)
Second day: 2 sessions 15 times each, pace – 3 times
per 2 sec
Pause - 10 sec
11. Squats with "load"
Initial position — main stance, middle of long bungee
behind shoulders, toes inside loops
12 --- 15 times, quick pace
12. Trunk bending and unbending with "load"
Initial position — main stance, middle of long bungee
behind shoulders, toes inside loops
At the end of unbending — rise on toes
Until slightly tired
13. Day 2:
Walking (Speed = 4.5 --- 5 km/h, T= 1 min)
Running, medium pace (Speed = 6.5 --- 7 km/h, T= 2 min)
Day 3, 1 cycle:
Walking (Speed = 5 km/h, T= 1 min)
Running (Speed = 8 km/h, T= 1 min)
14. "Hammer through" imitation
Initial position — press loop of middle bungee to TVIS belt
with right foot, hold second loop of the bungee with
both hands
Day 1: 10 times, T= 20 sec (1 time per 2 seconds)
Day 2: 12 times, pace: 1 time per 3 sec
Day 3: 2 sessions 10 times each, pace: 1 time per 2 sec,
pause - 15 sec
15. Day 1: Same as exercise 14 - in opposite direction
Day 3: Same as exercise 14 - in opposite direction
16. Breathing exercises with relaxation, 3 --- 4 times
17. First day 4 cycles successively, holding by hands
Walking (Speed = 5 km/h, T= 2 min)
Running (Speed = 14 km/h, T= 1 min)
Relaxed walking 30 sec
Second day 3 cycles: cycles 1 and 3 – no load
Walking (Speed =5 km/h, T= 2 min)
Running (Speed =8 km/h, T= 3 min)
cycle 2 – movement mode
Walking (Speed = 5 km/h, T= 2 min)
Running (Speed = 13 km/h, T= 3 min)
Relaxed walking 30 sec
Third day 3 cycles: cycles 1 and 2:
Walking (Speed = 5 km/h, T= 2 min)
Running (Speed = 13 km/h, T= 4 min)
cycle 3: walking (Speed = 5 km/h, T= 2 min)
Running (Speed = 8 km/h, T= 4 min)
Relaxed walking 30 sec
20-Oct-00
Magnet ← EMERGENCY
STOP
Belt stop
Magnet ← EMERGENCY
STOP
Belt stop
Magnet ← EMERGENCY
STOP
Belt stop
Magnet → EMERGENCY
STOP
Movement mode
Magnet ← EMERGENCY
STOP
Belt stop
Same as exercise 14
Belt stop
Magnet → EMERGENCY
STOP
Movement mode
Magnet → EMERGENCY
STOP
Combined mode
Magnet → EMERGENCY
STOP
Movement mode
МO book 2
Countermeasures
2-27E
Table 2.2 (continued)
18. Breathing exercises with relaxation, 3 --- 4 times
19.
21.
22.
23.
Hops with “load”
Initial position — main stance, middle of long bungee
behind shoulders, toes inside loops
2 sessions 20 times each, pause 10 --- 15 sec
Trunk bending and unbending with "load"
Initial position — main stance, middle of long bungee
behind shoulders, toes inside loops
At the end of unbending — rise on toes
Until slightly tired
First day cycle 1:
Walking (Speed = 5 /h, T= 2 min)
Running (Speed = 8 km/h, T= 3 min)
Second day cycle 1:
Walking (Speed = 5 km/h, T= 1 min)
Running (Speed = 8km/h, T= 2 min)
Third day cycle 1:
Walking (Speed = 5 km/h, T= 1 min)
Running (Speed = 8 km/h, T= 3 min)
First day:
Walking (Speed = 4.5 --- 5 km/h, T= 1 min)
Second day:
Walking (Speed = 4.5 --- 5 km/h, T=1 min)
Deep breathing exercise
Third day:
Walking (Speed = 4.5 --- 5 km/h, T= 1.5 min)
20-Oct-00
Magnet ← EMERGENCY
STOP
Belt stop
Magnet ← EMERGENCY
STOP
Belt stop
Magnet ← EMERGENCY
STOP
Belt stop
Magnet → EMERGENCY
STOP
Movement mode
Magnet → EMERGENCY
STOP
No-load
МO book 2
Table 2.3
Countermeasures
2-28E
20-Oct-00
МO book 2
Table 2.4
Countermeasures
2-29E
20-Oct-00
МO book 2
Table 2.5
Countermeasures
2-30E
20-Oct-00
МO book 2
Countermeasures
2-31E
20-Oct-00
2.5.2.1. MANUAL CONTROL MODE
NOTE
In manual control mode and exersise mode according to protocol TVIS belt speed can
be increased or decreased by the increment of 0.1 mile/h (0.16 km/h) by one-time
pushing of corresponding pushbuttons with arrows or by input of desired speed from
numeric keypad and G ENT
TVIS Cntl Pnl
1. G 1 (Transition to manual control mode)
& Digit 1 appears below the screen upper row
G ENT
" VIS STATUS MENU
2. Magnet → EMERGENCY STOP
" LED SYS PWR
If " LED SYS PWR, move magnet until LED color changes from
yellow to green
00:00:00
00:00:05
3. SLD SYSTEM LOAD SETUP
G ENT
" SUBJECT LOAD
Input required load using keypad
Recommended load = 2/3 of own weight
G ENT
% PREPARE FOR SLD LOAD
Stand in the center of belt
Stand still, knees slightly bent
% SLD LOADING
After end of loading
" Use arrow keys to readjust load if required
& Top row on screen shows actual load
G ↑ ( ↓ ) to increase (decrease) load
4. G ENT
" ENTER DESIRED BELT SPEED
% CHECK FOR BELT NOT LOCKED
√ TVIS belt resistance switch → 0
If exercise in movement mode
Perform Sect 2.5.2.2 page 2-32
If exercise in no load mode
Perform Sect 2.5.2.3 page 2-33
МO book 2
Countermeasures
2-32E
20-Oct-00
2.5.2.2. ACTIVATION MOVEMENT MODE
NOTE
1. For nominal and off-nominal stop of TVIS belt when in movement mode remove
magnet from EMERGENCY STOP position on Cntl Pnl
2. To resume operation wait for " SYSTEM PAUSED,
magnet → EMERGENSY STOP, G 1, G ENT
3. Performing exercise can be stopped at any time
G pb SYSTEM PAUSE
To resume operation in the same mode G 1 from menu SYSTEM PAUSED and
G ENT
TVIS Cntl Pnl
1.
If " BELT SPEED CONTROL
G 2, ENT
" ENTER DESIRED BELT SPEED
% CHECK FOR BELT NOT LOCKED
√ TVIS belt resistance switch → 0
2.
Stand on trestles on both sides of belt
Input required speed using keypad
G ENT
% PREPARE FOR BELT ACCELERATION
& Input speed is in the top row on screen
If belt does not accelerate to required speed, push it with your foot
G ↑ ( ↓ ) to increase (decrease) speed
3.
Carefully stand on TVIS belt and start walking (running)
& LCD screen shows:
actual speed
elapsed time
distance
heartrate
& EXERCISE PROFILE LCD screen – icon showing chosen type
of exercise
4.
Upon completion of walking (running)
G ↓ decrease speed to 2---3,2 km/h (2 miles/h)
G SYSTEM PAUSE
" SYSTEM PAUSED
G 4, ENT
" BELT SPEED CONTROL
00:00:00
00:00:05
МO book 2
Countermeasures
2-33E
20-Oct-00
2.5.2.3. ACTIVATION NO LOAD MODE
NOTE
In no load mode push with your foot resistance switch
above the belt surface to adjust resistance of belt
CAUTION!
Do not turn resistance switch of belt beyond 0---4 range
TVIS Cntl Pnl
00:00:00
1.
If " 'ENTER DESIRED BELT SPEED'
G 00, ENT
If " 'BELT SPEED CONTROL'
G 3, ENT
00:00:04
2.
.
" START PASSIVE SESSION
" PASSIVE SESSION
& Top row of screen – input speed, equal 0
Start exercise in no load mode
& LCD screens show:
actual speed
elapsed time
distance
heartrate
**********
*************************************************
√ Position of HRM transmitter
Wipe contacts
If problem persists
Unstow HRW clock, install and –
Report to MCC
*************************************************
3.
Upon completion of walking (running)
G SYSTEM PAUSE
" SYSTEM PAUSED
G 4, ENT
" BELT SPEED CONTROL
МO book 2
Countermeasures
2-34E
20-Oct-00
2.5.3. EXERCISE WITH PRE-PROGRAMMED PROTOCOL
TVIS Cntl Pnl
00:00:00
1.
G 2(3)(4) – on MCC GO
& Input number – in second row of screen
G ENT
" VIS STATUS MENU
& LCD screens show – zero values of
speed, time, distance, heart-rate
& EXERCISE PROFILE  icon
of chosen type of exercise
2.
Magnet → EMERGENCY STOP
" LED SYS PWR
If " LED SYS PWR, move magnet until LED color changes from
yellow to green
3.
G ENT
" 'AUTO-LOADING'
Follow instructions on LCD screen
% SLD AUTO – LOAD STARTING
% SLD LOADING
Upon end of auto-loading
" Use Arrow Keys To Readjust Load If Required
& Actual load shown in top row of screen
G ↑ ( ↓ ) to increase (decrease) load
4
GENT
% CHECK FOR BELT NOT LOCKED
√ TVIS belt resistance switch → 0
5.
Stand on trestles on both sides of belt
G ENT
% 'PREPARE FOR BELT ACCELERATION'
Belt starts moving at first speed according to protocol
Carefully stand on TVIS belt
Start walking (running)
Upon execution of protocol TVIS belt stops
" SYSTEM PAUSED
Perform Sect 2.5.4 page 2-35
00:00:05
00:00:10
00:00:00
00:00:05
00:00:10
МO book 2
Countermeasures
2-35E
20-Oct-00
2.5.4. CLOSEOUT
TVIS Cntl Pnl
TVIS Cntl Pnl
(top)
1. LOAD OFF
G 7 (Exit from system)
& Digit 7 appears in the screen upper row
G ENT
" FINAL SUBJECT LOAD
Stand in center of belt
2. CCM CARD REMOVING
G ENT
" REMOVE CCM CARD
G EJECT
Remove CCM card from slot
Close slot cover
" EXERCISE COMPLETE
" INSERT CCM
$ BELT SPEED
$ DISTANCE
$ HEARTRATE
$ ELAPSED TIME
$ EXERCISE PROFILE
3. Remove magnet from EMERGENCY STOP position
4. Side brackets clevises (two) ( from D-rings on waist strap of
TVIS suit
5. Bungees ( from Series Bungee System D-rings
If last subject has finished TVIS exercises
Fold side brackets to minimum height
Loosen knurled knobs (two)
Put brackets on belt
6. Bungees ( from D-rings on TVIS suit waist strap
Bungees (two) → into exercise kit
CCM card → into exercise kit
МO book 2
Countermeasures
2-36E
7. DOFFING OFF TVIS SUIT
Loosen shoulder straps
two front (green)
two back (purple)
Unfasten orange chest strap buckle
Loosen waist straps
two front (blue)
two back (yellow)
Unfasten two blue waist strap buckle
Unfasten Velcro strap
Doff TVIS suit
Dry suit
Stow TVIS suit into exercise kit
8. Remove HRM transmitter from chest strap
Wipe
Remove chest strap
Dry
Stow HRM transmitter and chest strap in HRM kit
Stow HRM kit (FGB zone 22)
TVIS Cntl Pnl
9. SYSTEM DEACTIVATION
Lift right switch protective cover on Cntl Pnl (top)
"LED
G STBL VIS (hold 1 --- 2 seс)
G GYRO VIS (hold 1 --- 2 seс)
"LED
" LED MOTOR TRD
" LED PWR TRD
Close switch protective cover
G SYS PWR
$ all LCD windows
pnl 435
БВП - 20
БВП - 20
" LED
I OFF (left)
I OFF (right)
10. Stow exercise kit
11. Take off training underwear, footwear
12. Perform sanitary hygienic activities
20-Oct-00
МO book 2
Countermeasures
2-37E
20-Oct-00
2.5.5. OFF-NOMINAL SITUATIONS
LCD Message
Meaning
User’s actions
EXERCISE PROFILE LCD
" TM FAULT
UNDERVOLTAGE X Y Z
VOLTS
Low TVIS power
(U ≤24 V)
Decrease belt speed until
message disappears
Continue exercise with this speed
~10 min
Return to initial speed
& Does message reappear
If message reappears
Decrease speed
Complete exercise
Report to MCC
% VIS FAULT S
VIS stabilizer failure
Also number of stabilizer
that failed is shown
Not required
Gyro failure
G SYSTEM PAUSE
" SYSTEM PAUSED
Deactivate system according to
Sect 2.5.4 steps 1 - 3, 9
page 2-35, 2-36
Activate system according to
Sect 2.5.1 steps 5 - 8, 10, 11
page 2-22, 2-23
If at second activation trouble
persists, repair or replace
change gyro
% G
If failure causes unstable belt
condition:
G SYSTEM PAUSE
" SYSTEM PAUSED
G 2, ENT
" VIS STATUS/CONTROL
G 1, ENT
" VIS CONTROL
G 5, ENT
" …STBL OFF
% VIS FAULTS S1S2S3S4
G 4, ENT
$ VIS FAULTS S1S2S3S4
" STBL ON
МO book 2
% US
Countermeasures
2-38E
20-Oct-00
Gyro underspeed
V < 1800 rpm
G SYSTEM PAUSE
" SYSTEM PAUSED
G 2, ENT
" VIS STATUS/CONTROL
& GYRO SPEED 2000
G SYSTEM PAUSE
" SYSTEM PAUSED
G 1, ENT
If speed does not increase
" VIS STATUS/CONTROL
G 1, ENT
" VIS CONTROL
G 3, ENT
" GYRO OFF
Wait till full stop ~ 10 min
G 2, ENT
" GYRO ON
G 7, ENT
" VIS STATUS/CONTROL
& GYRO SPEED 2000
Unstable belt
G SYSTEM PAUSE
Only per MCC instructions
VIS control loop gain adjustment
1. VIS controller → in manual
control mode:
Perform Sect 2.5.4 steps 1, 2
page 2-35
Perform Sect 2.5.1.1 steps 5, 6
page 2-24
Perform Sect 2.5.2.1 step 1
page 2-31
2. Adjust X selector
G SYSTEM PAUSE
" SYSTEM PAUSED
G 2 , ENT
" VIS STATUS/CONTROL
G 1, ENT
" VIS CONTROL
G 6, ENT
" PITCH/GAIN CONTROLS
G 1, ENT (pitch angle control
gain setting)
G 2, ENT (Y-axis movement
control gain setting)
MO book 2
HEALTH MONITORING
3-1E
25-Sep-00
3. HEALTH MONITORING
3.1. BP MEASUREMENT WITH SPHYGMOMANOMETER TENSOPLUS
3.1.1. SETUP
1.
Open case
2.
Unstow blood pressure cuff from the case
3.
Secure cuff on the arm appr. 2-3 cm above the elbow crease using Velcro clip (cuff
arrow being on the arm’s inside, with rubber air hose directed downwards)
4.
Cuff air connector ! sphygmomanometer air inlet МАНЖЕТА
5.
sw OFF-ON → ON
6.
" (over 5 sec) the data displayed on digital readout:
**********
************************************
If display shows
sw OFF-ON → OFF
Install a fresh set of batteries
************************************
MO book 2
HEALTH MONITORING
3-2E
25-Sep-00
3.1.2. BLOOD PRESSURE MEASUREMENT
NOTE
Avoid sudden movements of the Subject during BP measurement
1.
# START
2.
Note blood pressure and pulse rate values from digital readout and enter the results
in Table 3.1 p. 3-4
**********
****************************************
If message ' Еrr 330 ' is displayed, check cuff
setup and position, and the cuffsphygmomanometer correct connection
Repeat steps 1-2
****************************************
3.
sw OFF-ON → OFF
4.
Cuff air connector $ sphygmomanometer
5.
Remove cuff
6.
Stow cuff and sphygmomanometer in the case
7.
Stow the case
MO book 2
HEALTH MONITORING
3-3E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-4E
25-Sep-00
Table 3.1 Arterial Blood Pressure and Pulse Rate Log Sheet
Name
Date
BP
PR
MO book 2
HEALTH MONITORING
3-5E
25-Sep-00
Table 3.1 (cont.)
Name
Date
BP
PR
MO book 2
HEALTH MONITORING
3-6E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-7E
25-Sep-00
3.2. MO-1 INVESTIGATING HEART BIOELECTRICAL ACTIVITY AT REST
Hardware:
GАММА-1 equipment
УСИ ЭКГ sensors
ГАММА-1 set
ВБ-3 cycle ergometer
Wet wipes
Figure 3.1 Subject's Outfitting for MO-1 Operations
MO book 2
HEALTH MONITORING
3-8E
Figure 3.2 Physiological Curves after ПКО-ЭКГ → 1
25-Sep-00
MO book 2
HEALTH MONITORING
3-9E
Figure 3.3 Physiological Curves after ПКО-ЭКГ → 2
25-Sep-00
MO book 2
HEALTH MONITORING
3-10E
25-Sep-00
1.
Install cycle ergometer into working position (see МО Book 1 Sect. 5.4.1 p. 5-15)
Depress fixer latch and remove pedals
Stow pedals in seat cover pocket
2.
Adjust generator assembly and seat positions:
Pull fixer latch sleeve on the required rod in the arrow direction
Adjust generator assembly or seat position as convenient
Release fixer latch sleeve
Move generator assembly or seat position until captured (wait for audible click)
3.
Setup the required hardware
3.2.1. INITIAL SETUP
(00:15:00)
NOTE
Assistant helps Subject with outfitting
1.
Unstow ПКО-ЭКГ biomed harness belt from
УСИ ЭКГ bag
2.
Moisten belt electrode pads, using conductive
fluid from ГАММА-1 set
3.
Don ЭКГ belt at 5th intercostal level
Adjust belt and straps to desired length,
engaging hook into required loops,
maintaining symmetry relative to backbone
√ V4,V5,V6 electrodes are located at 5th
intercostal level on the left
" V4,V5,V6 electrodes match the labeling on
ПКО
4.
Turn belt down
Treat skin in electrode application areas,
using wet wipe
√ correct placement and good contact of ECG
electrodes with Subject's skin
5.
Mount the cycle ergometer
Assist Subject with outfitting
MO book 2
HEALTH MONITORING
3-11E
6.
Unstow the following ECG electrodes
from biomed harness pockets:
ПР (right arm), ЛР (left arm),
ПН (right leg), ЛН (left leg)
Moisten electrode pads, using
conductive fluid from ГАММА-1 set
7.
Treat skin in electrode application areas
(inner surfaces of lower thirds of
shins and forearms), using wet wipe
8.
Attach electrodes to Subject’s arms and
legs (see Figure 3.1 p. 3-7):
ПН, ЛН - on the right and left shins
(lower third of inner-anterior surface)
ПР, ЛР - on the right and left forearm
(lower third of inner surface)
9.
25-Sep-00
connector ПКО ЭКГ →|← connector EKG
HARNESS on MEDICAL EXAM PANEL
10.
sw on ПКО-ЭКГ cable → 1
11.
% <GAMMA> MED SYS on ППС-24
% PANEL PWR on MEDICAL EXAM PANEL
& LED PANEL PWR
12.
sw OPERATIONAL MODES
on MEDICAL EXAM PANEL → OSC
13.
On OSCILLOSCOPE:
sw OPERATIONAL MODES → SWEEP
sw BRIGHTNESS → middle position
sw SWEEP VELOCITY→ middle position
14.
Set signal amplitude on MEDICAL EXAM PANEL:
sw GAIN I, II, III → 3
sw GAIN IV, V, VI → 2
NOTE
Gain settings for all recorded physiological curves may be changed on MCC GO
15.
" presence and proper waveform of signals (see
Figure 3.2 p. 3-8), sequentially toggle on
MEDICAL EXAM PANEL:
sw OSCILLOSCOPE → I - VI
MO book 2
HEALTH MONITORING
3-12E
25-Sep-00
16.
sw on cable ПКО-ЭКГ → 2
17.
" presence and proper waveform of signals
(see Figure 3.3 p. 3-9), sequentlially toggle on MEDICAL
EXAM PANEL:
sw OSCILLOSCOPE → I - VI
18.
sw on cable ПКО-ЭКГ → 1
3.2.2. MCC CONTROLLED OPERATION
(Telemetry Session)
1.
Т.0
At complete rest
(physiological parameters will be
recorded throughout the whole TM
session)
2.
Inhale deeply and hold breath for 10 sec
3.
sw OPERATIONAL MODES
on MEDICAL EXAM PANEL → TLM GAIN
After 10 sec OPERATIONAL MODES → OSC
4.
Sequentially toggle sw GAIN I − VI
on MEDICAL EXAM PANEL (On MCC GO)
5.
sw on cable ПКО-ЭКГ → 2
sw on cable ПКО-ЭКГ → 1
6.
Т.КТМ (end of telemetry session)
3.2.3. CLOSEOUT OPERATIONS
(00:10:00)
1.
' PANEL PWR on MEDICAL EXAM PANEL
PANEL PWR
2.
connector ПКО ЭКГ ←|→ connector EKG HARNESS
on MEDICAL EXAM PANEL
' <GAMMA> MED SYS on ППС-24
3.
Dismount cycle ergometer
4.
Doff biomed harness
Dry out biomed harness
Stow biomed harness and all
accessories
5.
Stow cycle ergometer (see МО Book 1 Sect. 5.4.3 p.5-18)
MO book 2
HEALTH MONITORING
3-13E
25-Sep-00
3.3. MO-2 ECG 24-HOUR RECORDING
Purpose:
Recording of dynamic electrocardiograms (ДЭКГ), obtained from two leads over 24
hours
Hardware Components:
'Кардиорегистратор 90205' ECG recorder kit (unit in case, belt, patient cables)
'Кардиорегистратор 90205' accessories kit (electrodes, tape cassettes and
batteries)
3.3.1. SETUP FOR OPERATION
1.
Unstow kits with ECG recorder and accessories kit
Secure kits in work area
2.
Unstow ECG recorder and power battery from kits
3.
Remove ECG recorder from the case
Open ECG recorder cover
Install the battery into battery compartment (observing correct polarity)
Close ECG recorder cover and put it back in the case
NOTE
After ECG recorder cover has been closed, you should hear ECG recorder motor
running
4.
√&
hrs, min (on digital readout)
If displayed time differs from SM onboard clock, adjust ECG recorder internal clock in
the following way:
Open ECG recorder cover
#(using a pointed object) pb S (in the right upper corner of the unit)
(
min
Set minutes, by pressing pb А
# pb S )
min
(
hr
Set hours, by pressing pb А
# pb S &
hr, min (clock resumes time count)
MO book 2
HEALTH MONITORING
3-14E
25-Sep-00
3.3.2. ELECTRODES INSTALLATION AND ECG RECORDING
1.
Undress from the waist up
2.
Unstow wet and dry wipes from Accessories Kit
Carefully wipe electrode application areas (see Figure 3.4 p. 3-14), first with a wet
wipe, then with a dry one
NOTE
If necessary, shave off the hair in electrode application areas, using safety razor
from the Accessories Kit
3.
Unstow electrodes from accessories kit
Cut open individual packages
4.
Apply color-coded electrodes to skin (see Figure 3.4 p. 3-14):
(1) white
right part of thorax under clavicle
(2) brown
left part of thorax under clavicle
(3) black
right part of thorax near 4th rib sternum attachment point
(4) red
between the 5th and 6th rib (left part of thorax on clavicule midline)
(5) green
between the 5th and 6th rib (to the right part of thorax in any place)
5.
Unstow electrode cable from Accessories kit
ECG recorder ! patient cable ! electrodes (see Figure 3.4 p. 3-14), making
unloading loops, and route the lead wire through the slots in electrode patch
" colors of electrodes match colors of cable connectors
Discard packaging
Figure 3.4 Electrode Application Diagram
MO book 2
HEALTH MONITORING
3-15E
6.
Unstow labeled cassette (on MCC GO)
Remove retainer tab from the cassette, discard retainer tab
7.
Record date, time, and subject's name on the cassette label
Install the cassette into ECG recorder (with the label facing upwards)
8.
Close ECG recorder cover
* motor is audible
" tape in cassette is moving
9.
Stow ECG recorder in its case
Secure ECG recorder on the waist using belt
10.
Stand by while calibration sequence runs for 12 min
NOTE
Do not open ECG recorder cover during the whole 24-hour ECG recording
session
11.
ECG recording will start and should continue for 24 hours
3.3.3. CLOSEOUT OPERATIONS
1.
Patient cable ←|→ ECG recorder and electrodes
Stow cable in ECG recorder kit
2.
Detach electrodes from skin
Wipe electrode application areas with a wet wipe (from accessories kit)
Discard used electrodes and wipes
3.
Remove ECG recorder from its case
Open cover and take out the cassette and battery
Discard battery
4.
Close ECG recorder cover, put ECG recorder in its case
Stow case with ECG recorder in ECG recorder kit
Stow ECG recorder kit
5.
Stow the cassette in accessories kit ‘Кардиорегистратор 90205’
25-Sep-00
MO book 2
HEALTH MONITORING
3-16E
25-Sep-00
3.4. МО-4 ORTHOSTATIC STABILITY EVALUATION WITH LBNP
Hardware:
GАММА-1 equipment
РПГ КОММУТАТОР
Chibis LBNP system
УСИ ВАП-ККГ sensors
УСИ РПГ-1 sensors
УСИ РЭГ-1 sensors
УСИ АД sensors
УСИ ВПГ sensors
ГАММА-1 set
Wet wipes
Dry wipes
Figure 3.5 Subject's Outfitting for MO-4
MO book 2
HEALTH MONITORING
3-17E
Figure 3.6 Physiological curves for МО-4
25-Sep-00
MO book 2
HEALTH MONITORING
3-18E
25-Sep-00
1. Prepare required equipment and hardware
2. connector ВЫХОД of cable 5А4.856.922 →|← connector ВЫХОД (on РПГ КОММУТАТОР
side panel)
3. connectors ВХОД I and ВХОД II of cable 5А4.856.922 →|← connectors ВХОД I and ВХОД II
(on РПГ КОММУТАТОР panel)
4. Temp stow РПГ КОММУТАТОР
3.4.1. INITIAL SETUP
(00:20:00)
NOTE
Assistant helps Subject with outfitting
1.
Unstow ПКО ЭКГ-ККГ biomed harness belt
from УСИ ВАП-ККГ bag
2.
Moisten ЭКГ-ККГ belt electrode pads using
conductive fluid from ГAMMA-1 set
3.
Don ЭКГ-ККГ belt at 5th intercostal level
(Figure 3.5 p. 3-16)
Adjust belt and straps to desired length
4.
Turn belt down
Treat skin in ECG electrode application areas
using wet wipe
Apply electrodes to the body
√ Correct placement (see Figure 3.5 p. 3-16)
and good contact of ECG-DS electrodes
with Subject's skin
" ECG electrodes conform to corresponding
"D", "S", "O" labels on biomed harness
belt
5.
Remove cover from Chibis suit
Remove shackle strap from Chibis suit
Unstow hose harness from the kit
Hose harness →|← connectors of Chibis suit
and <CHIBIS> SUIT PRESSURE
CONTROL
6.
Get into Chibis suit
Pull Chibis suit drum up to waistline
Don Chibis suit shoulder straps
Assist Subject with outfitting
MO book 2
HEALTH MONITORING
3-19E
25-Sep-00
7.
connector ПКО ЭКГ-ККГ →|← connector EKG HARNESS on
MEDICAL EXAM PANEL
8.
Unstow ШКО РЭГ-1 biomed cap (of a required size) from УСИ РЭГ-1
bag
9.
√ Numbers on electrodes match lables on ШКО РЭГ-1 biomed cap
Moisten ШКО РЭГ-1 electrode pads using conductive fluid from
ГАММА-1 set
CAUTION
Do not allow hair get under the electrodes
10.
Don ШКО РЭГ-1 biomed cap on the head (lable "ЛОБ" should be on
the forehead)
Place electrodes, making sure to brush hair aside
Turn down biomed cap straps
Treat skin in РЭГ electrodes application areas, using wet wipe pad
11.
√ Correct placement of electrodes (see Figure 3.5 p. 3-16):
## 3, 4 and 7, 8 – on the left and right mastoid processes of
temporal bones (behind ears)
## 1, 5 and 2, 6 – on the left and right sides of the forehead
12.
Unstow РПГ-1 ПЛЕЧО-ПЛЕЧО from УСИ РПГ-1 bag
13.
Secure РПГ-1 electrodes (ПЛЕЧО ЛЕВОЕ on the left arm and
ПЛЕЧО ПРАВОЕ on the right arm) on the borderline between
upper and middle thirds of left and right arms respectively (with
arrow directed towards palm)
14.
connector ВХОД I РПГ-1 (ПЛЕЧО-ПЛЕЧО) →|← connector РПГ-1
(ВХОД I) of РПГ КОММУТАТОР (on the left)
connector ВХОД I РЭГ on ШКО РЭГ-1 →|← connector РЭГ
(ВХОД I) of РПГ КОММУТАТОР (on the left)
connector ВХОД II РЭГ on ШКО РЭГ-1 →|← connector РЭГ
(ВХОД II) of РПГ КОММУТАТОР (on the right)
15.
Unstow blood pressure cuff from УСИ АД bag
MO book 2
HEALTH MONITORING
3-20E
25-Sep-00
16.
Secure blood pressure cuff on the left arm, with sensor located approximally
2 cm above the elbow crease on the inside of arm
17.
Cuff hose →|← inlet CUFF on BLOOD PRESSURE PANEL
Cuff cable →|← connector PRESSURE-SOUND on BLOOD PRESSURE
PANEL
18.
On BLOOD PRESSURE PANEL:
sw OPERATIONAL MODE → PRESSURE WAVE FORM
sw MODE → AUTO
sw mm Hg → 180
19.
% <GAMMA> MED SYS on ППС-24
% CHIBIS MED SYS on ППС-24
20.
% PANEL PWR on MEDICAL EXAM PANEL
& LED PANEL PWR on MEDICAL EXAM PANEL
& upper LED on BLOOD PRESSURE PANEL
& LED on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>
21.
sw OPERATIONAL MODES on MEDICAL EXAM PANEL → OSC
22.
On OSCILLOSCOPE:
sw OPERATIONAL MODES → SWEEP
sw BRIGHTNESS → middle position
sw SWEEP VELOCITY → middle position
23.
On КОММУТАТОР РПГ:
left sw PROGRAM → 2
right sw PROGRAM → OFF
24.
Set signal amplitude:
sw GAIN II on MEDICAL EXAM PANEL → 5
sw GAIN on BLOOD PRESSURE PANEL → 3
Set GAIN I on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>:
RO → 3
ΔR → 4
25.
" presence and proper waveform of signals (Figure 3.6, p.3-17),
sequentially toggle on MEDICAL EXAM PANEL:
OSCILLOSCOPE → II (ЭКГ-DS)
OSCILLOSCOPE → III (dR/dt)
OSCILLOSCOPE → IV (РЭГ (ΔR and RO sequentially))
MO book 2
HEALTH MONITORING
3-21E
25-Sep-00
26.
Unstow ВПГ sensor from УСИ ВПГ bag
27.
Connector of ВПГ sensor →|← ВПГ connector on ПКО biomed harness
(without donning ВПГ sensor, which is used only to complete the circuit)
Temp stow ВПГ sensor in a convenient location
28.
On КОММУТАТОР РПГ:
left sw PROGRAM → 1
right sw PROGRAM → OFF
29.
Set signal amplitude:
Set GAIN I on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>:
RO → 3
ΔR → 2
30.
" presence and proper waveform of signals (Figure 3.6, p. 3-17),
sequentially switching on MEDICAL EXAM PANEL:
OSCILLOSCOPE → II (ЭКГ)
OSCILLOSCOPE → IV (РПГ (ΔR and RO sequentially))
31.
# START on BLOOD PRESSURE PANEL
32.
" presence and proper waveform of signals (Figure 3.6, p.3-17),
sequentially toggle on MEDICAL EXAM PANEL:
OSCILLOSCOPE → V (АД-ТО)
OSCILLOSCOPE → VI (ОД)
33.
Tighten Chibis waist belt (belt pad of removable waste seal curtain should be
in the small of the back)
NOTE
Gain settings for all recorded physiological curves may be changed on MCC GO
MO book 2
HEALTH MONITORING
3-22E
25-Sep-00
3.4.2. MCC CONTROLLED OPERATION
(Telemetry Session)
NOTE
For order of steps during telemetry session (controlled by MCC), see Table 3.2 p. 3-24
1.
Т.0
At complete rest
(physiological parameters
before test are being
recorded)
2.
Hold breath for 10-15 sec
3.
On MEDICAL EXAM PANEL:
sw OPERATIONAL MODES → TLM GAIN
After 10 sec, sw OPERATIONAL MODES → OSC
4.
On КОММУТАТОР РПГ:
left sw PROGRAM → 1
5.
connector of ВПГ sensor →|← connector ВПГ on ПКО
biomed harness
6.
On КОММУТАТОР РПГ:
left sw PROGRAM → 2
7.
cnctr of ВПГ sensor ←|→ cnctr ВПГ on ПКО biomed harness
8.
# START on BLOOD PRESSURE PANEL
9.
sw on <CHIBIS> SUIT PRESSURE CONTROL → AUTO
VACUUM
LED on <CHIBIS> SUIT PRESSURE CONTROL
W ARNING
To return to ambient pressure in an emergency, quickly loosen Chibis suit waist belt and
break seal around body
10.
By gradually rotating РАЗРЕЖЕНИЕ knob over 10 sec, set 25
mmHg to last for 1 min
11.
By gradually rotating РАЗРЕЖЕНИЕ knob over 10 sec, set 35
mmHg to last for 2 min
12.
By gradually rotating РАЗРЕЖЕНИЕ knob over 10 sec, set 40
mmHg to last for 3 min
MO book 2
HEALTH MONITORING
3-23E
25-Sep-00
13.
By gradually rotating РАЗРЕЖЕНИЕ knob
over 10 sec, set 50 mmHg to last for 3 min
14.
By gradually rotating РАЗРЕЖЕНИЕ knob
back over 30 sec, equalize the pressure
inside Chibis with the ambient pressure
(pressure gauge dial should read 0 mmHg)
15.
At complete rest (physiological parameters
after test are being recorded)
16.
Т.КТМ (end of TM session)
17.
sw on <CHIBIS> SUIT PRESSURE
CONTROL → OFF
) LED <CHIBIS> on SUIT
PRESSURE CONTROL
3.4.3. CLOSEOUT OPERATIONS
(00:15:00)
1.
' PANEL PWR on MEDICAL EXAM PANEL
) LED PANEL PWR on MEDICAL EXAM
PANEL
) upper LED on BLOOD PRESSURE
PANEL
) LED on RHEOPLETHYSMOGRAPHY
PANEL <GAMMA-1>
2.
Sensor connectors $ connectors of
<GАММА-1М> units (all)
3.
' <GAMMA> MED SYS on ППС-24
' CHIBIS MED SYS on ППС-24
4.
Get out of Chibis suit
hose harness ←|→ Chibis suit
5.
Doff ПКО ЭКГ-ККГ, РПГ-1, ШКО РЭГ-1,
ВПГ sensor, blood pressure cuff
Dry out ПКО ЭКГ-ККГ, ШКО РЭГ-1
6.
Wipe inside surface of Chibis suit waist seal
curtain using wipe
Dry out Chibis suit for 30-60 min using air
blowing from airduct outlets
7.
Fold Chibis suit
Reinstall shackle strap
Stow air hoses
Install cloth cover on Chibis suit
Stow Chibis suit
Stow ПКО ЭКГ-ККГ, РПГ-1, ШКО РЭГ-1,
ВПГ sensor, blood pressure cuff
Left switch → 2
ВПГ # cnctr ВПГ ПКО
5
min
continuously recorded during test performance
4
min
Left
switch → 1
ВПГ "
1
min
2
3
min min
РЭГ
GAIN I
∆R → 4
4
min
After test
Left switch → 2
ВПГ # cnctr ВПГ ПКО
-40
-50
mm Hg
mm Hg
1
2
3
1
2
3
min min
min
min
min min
РПГ-1
GAIN I
∆R → 2
5
min
3-24E
ЭКГ - DS
Left
switch →1
Коммутатор РПГ
3
min
-35
mm Hg
1
1
2
min min min
РЭГ
GAIN I
∆R → 4
-25
HEALTH MONITORING
ВПГ "
1
2
min
min
РПГ-1
GAIN I
∆R → 2
Prior to test
Rheoplethysmography Panel <Gamma-1> [РПГ] and Коммутатор РПГ (РПГ switch):
РПГ-1 and ШКО РЭГ-1 " Коммутатор РПГ
The right switch ПРОГРАММА (program) of коммутатора РПГ → ВЫКЛ (Off)
Blood pressure panel:
MODE → AUTO
OPERATIONAL MODE → PRESSURE WAVE FORM
Mm Hg → 180
! START every other minute of test performance
МО-4 ACTIVITIES SEQUENCE
MO book 2
25-Sep-00
Table 3.2 МО-4 Activities Sequence
MO book 2
HEALTH MONITORING
3-25E
25-Sep-00
3.5. МО-5 CARDIOVASCULAR EVALUATION DURING GRADED EXERCISES
ON CYCLE ERGOMETER
Hardware:
GАММА-1 equipment
ВБ-3 cycle ergometer
УСИ ВАП-ККГ sensors
УСИ РПГ-1 sensors
УСИ АД sensors
УСИ ВПГ sensors
ГАММА-1 set
Wet wipes
MO book 2
HEALTH MONITORING
3-26E
25-Sep-00
Figure 3.7 Outfitting Diagram and Reference Physiological Curves for МО-5
MO book 2
HEALTH MONITORING
3-27E
25-Sep-00
1.
Install cycle ergometer into working position (see МО Book 1 Sect. 5.4.1 p. 5-15)
2.
Adjust generator assembly and seat positions:
Pull fixer latch sleeve on the required rod in the arrow direction
Adjust generator assembly or seat position as convenient
Release fixer latch sleeve
Move generator assembly or seat position until captured (wait for audible click)
3.
Setup the required hardware
3.5.1. INITIAL SETUP
(00:15:00)
NOTE
Assistant helps Subject with outfitting.
1.
Unstow ПКО ЭКГ-ККГ biomed harness belt from
УСИ ВАП-ККГ bag
2.
Moisten ЭКГ-ККГ belt electrode pads using
conductive fluid from ГАММА-1 set
3.
Don ЭКГ-ККГ belt at 5th intercostal level (Figure 3.7
p. 3-26)
Adjust straps and belt to desired length
4.
Turn belt down
Treat skin in ECG electrode application areas
using wet wipe
Apply electrodes to the body
√ correct placement and good contact of ECG-DS
electrodes with skin
" ECG electrodes conform to corresponding “D",
"S", "O" lables on biomed harness belt
5.
Mount the cycle ergometer
# [X] on cycle ergometer control panel
6.
Assist Subject with outfitting
Cnctr ПКО ЭКГ-ККГ →|← cnctr EKG
HARNESS on MEDICAL EXAM
PANEL
MO book 2
HEALTH MONITORING
3-28E
25-Sep-00
7.
Unstow РПГ-1 ПЛЕЧО-ПЛЕЧО from УСИ РПГ-1 bag
8.
Secure РПГ-1 electrodes (ПЛЕЧО ЛЕВОЕ on the left arm and
ПЛЕЧО ПРАВОЕ on the right arm) on the borderline between
upper and middle thirds of left and right arms respectively (with
arrow directed towards palm) (Fig. 3.7 p. 3-26)
9.
connector ВХОД I РПГ-1 (ПЛЕЧО-ПЛЕЧО) →|← connector ВХОД I
on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>
10.
Unstow blood pressure cuff from УСИ АД bag
11.
Secure blood pressure cuff on the left arm, with sensor located
approximately 2 cm above elbow crease, on inner side of arm
12.
cuff hose →|← CUFF inlet on BLOOD PRESSURE PANEL
cuff cable →|← connector PRESSURE-SOUND on BLOOD
PRESSURE PANEL
13.
On BLOOD PRESSURE PANEL:
sw OPERATIONAL MODE → <KOROTKOV> SOUND
sw MODE → AUTO
sw mm Hg →180
14.
Obtain ВПГ sensor from УСИ ВПГ bag
15.
connector of ВПГ sensor →|← connector ВПГ on biomed harness
(ВПГ sensor is not donned, sensor assembly is used only to
complete the circuit)
16.
% <GAMMA> MED SYS on ППС-24
17.
% PANEL PWR on MEDICAL EXAM PANEL
& LED PANEL PWR on MEDICAL EXAM PANEL
& LED (upper) on BLOOD PRESSURE PANEL
& LED on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>
18.
sw OPERATIONAL MODES on MEDICAL EXAM PANEL → OSC
19.
On OSCILLOSCOPE:
sw OPERATIONAL MODES → SWEEP
sw BRIGHTNESS → middle position
sw SWEEP VELOCITY→ middle position
MO book 2
HEALTH MONITORING
3-29E
25-Sep-00
20.
Set signal amplitude:
GAIN II on MEDICAL EXAM PANEL → 5
GAIN I on RHEOPLETHYSMOGRAPHY PANEL <GAMMA-1>:
RO → 3
ΔR → 1
21.
" presence and proper waveform of signals (Figure 3.7 p.3-26),
sequentially switching on MEDICAL EXAM PANEL:
sw OSCILLOSCOPE → II (ЭКГ)
sw OSCILLOSCOPE → IV (РПГ (ΔR and RO sequentially))
22.
# START on BLOOD PRESSURE PANEL
23.
" presence and proper waveform of signals (Figure 3.7 p. 3-26),
sequentially toggle on MEDICAL EXAM PANEL:
sw OSCILLOSCOPE → V (АД-ТК)
sw OSCILLOSCOPE → VI (ОД)
NOTE
Gain settings for all recorded physiological curves may be changed on MCC GO
MO book 2
HEALTH MONITORING
3-30E
25-Sep-00
3.5.2. MCC CONTROLLED OPERATION
(Telemetry Session)
NOTE
For sequence of steps during telemetry session, see Table 3.3 p. 3-32
1.
Т.0
At complete rest (physiological
parameters before test are being
recorded)
On MEDICAL EXAM PANEL:
sw OPERATIONAL MODES → TLM GAIN
Wait for 10 sec, then
sw OPERATIONAL MODES → OSC
2.
On BLOOD PRESSURE PANEL:
Start pedaling and after
LED on display,
set load setting 125 W by pressing right pb
sw mm Hg → 180
∆ on cycle ergometer control panel
sw mm Hg → 240
3.
Work pedals for 3 min at medium speed
(60-70 rpm)
4.
Set load setting 150 W by pressing right pb ∆
on cycle ergometer control panel
5.
Work pedals for 3 min at medium speed
6.
Set load setting 175 W by pressing right pb ∆
on cycle ergometer control panel
7.
Work pedals for 3 min at medium speed
8.
At complete rest (physiological parameters
after test are being recorded)
9.
Т.КТМ (end of telemetry session)
# START on BLOOD PRESSURE PANEL
MO book 2
HEALTH MONITORING
3-31E
25-Sep-00
3.5.3. CLOSEOUT OPERATIONS
(00:15:00)
1.
' PANEL PWR on MEDICAL EXAM PANEL
) PANEL PWR on MEDICAL EXAM PANEL
) LED (upper) on BLOOD PRESSURE PANEL
) LED on RHEOPLETHYSMOGRAPHY PANEL
<GAMMA-1>
2.
connector on ВПГ sensor ←|→ connector ВПГ on ПКО
biomed harness
connectors ПКО ЭКГ-ККГ, РПГ-1, blood pressure
cuff ←|→ connectors of <GАММА-1М> units
3.
' <GAMMA> MED SYS on ППС-24
4.
# [X] on cycle ergometer
control panel
Dismount cycle ergometer
5.
Doff ПКО ЭКГ-ККГ, РПГ-1,
ВПГ sensor, blood pressure
cuff
Dry out ПКО ЭКГ-ККГ
electrode pads
Stow ПКО ЭКГ-ККГ, РПГ-1,
ВПГ sensor, blood pressure
cuff
6.
Stow cycle ergometer (see МО Book 1 Sect. 5.4.3 p.5-18)
↑
↑
↑
5
мин
1
min
↑
2
min
3
min
1
min
↑
2
3
1
min
min
min
Mm Hg → 240
150 W
↑
2
min
175 W
3
min
↑
1
min
ЭКГ - DS and РПГ-1 continuously recorded during test performance
↑ - ! START on blood pressure panel (during load – at the end of the second minute of each step)
↑
2
3
4
min
min min
Mm Hg → 180
125 W
↑
2
min
↑
↑
↑
3
4
5
min min min
Mm Hg → 180
After test
HEALTH MONITORING
↑
1
min
Prior to test
Rheoplethysmography Panel <Gamma-1> [РПГ]:
cnctr КО РПГ-1 " cnctr INPUT I on РПГ
cnctr of ВПГ sensor " ВПГ cnctr on EKG HARNESS
Blood pressure panel:
MODE → AUTO
OPERATIONAL MODE → KOROTROV SOUND
mm Hg . → per activities sequence
МО-5 ACTIVITIES SEQUENCE
MO book 2
3-32E
25-Sep-00
Table 3.3 МО-5 Activities Sequence
MO book 2
HEALTH MONITORING
3-33E
25-Sep-00
3.6. МО-6 HAND CYCLE ERGOMETRY
Hardware:
GАММА-1 equipment
ВБ-3 Cycle ergometer
УСИ ВАП-ККГ sensor
ГАММА-1 set
Wet wipes
Figure 3.8 Outfitting Diagram and Reference Physiological Curves for МО-6
MO book 2
HEALTH MONITORING
3-34E
1.
Install cycle ergometer into working position (see МО Book 1 Sect. 5.4.1 p. 5-15)
Depress fixer latch and remove pedals
Stow pedals in seat cover pocket
2.
Adjust generator assembly and seat positions:
Pull fixer latch sleeve on the required rod in arrow direction
Adjust generator assembly or seat position as convenient
Release fixer latch sleeve
Move generator assembly or seat position until captured (wait for audible click)
3.
Setup the required hardware
3.6.1. INITIAL SETUP
(00:10:00)
NOTE
Assistant helps Subject with outfitting
1.
Unstow ПКО ЭКГ-ККГ biomed harness belt
from УСИ ВАП-ККГ bag
2.
Moisten ЭКГ belt electrode pads using
conductive fluid from ГАММА-1 set
3.
Don ЭКГ-ККГ harness at 5th intercostal level
(Figure 3.8 p. 3-33)
Adjust straps and belt to desired length
4.
Turn belt down
Treat skin in electrode application areas, using
wet wipe
Apply electrodes to the body
√ correct placement and good contact of ECGDS electrodes with skin
" ECG electrodes conform to corresponding
“D", "S", "O" lables on ПКО biomed harness
5.
Mount the cycle ergometer
# [X] on cycle ergometer control panel
Assist Subject with outfitting
25-Sep-00
MO book 2
HEALTH MONITORING
3-35E
25-Sep-00
6.
connector ПКО ЭКГ-ККГ →|← connector EKG HARNESS on
MEDICAL EXAM PANEL
7.
% <GAMMA> MED SYS on ППС-24
% PANEL PWR on MEDICAL EXAM PANEL
& LED PANEL PWR on MEDICAL EXAM PANEL
8.
sw OPERATIONAL MODES on MEDICAL EXAM PANEL → OSC
9.
On OSCILLOSCOPE:
sw OPERATIONAL MODES → SWEEP
sw BRIGHTNESS → middle position
sw SWEEP VELOCITY→ middle position
10.
" presence and proper waveform of signals (Figure 3.8 p. 3-33),
sequentially toggle on MEDICAL EXAM PANEL:
GAIN II → 5
OSCILLOSCOPE → II (ЭКГ)
NOTE
Gain settings for all recorded physiological curves may be changed on MCC GO
3.6.2. MCC CONTROLLED OPERATION
(Telemetry Session)
1.
Т.0
At complete rest (physiological
parameters before test are being
recorded)
On MEDICAL EXAM PANEL:
sw OPERATIONAL MODES → TLM GAIN
Wait for 10 sec, then
sw OPERATIONAL MODES → OSC
2.
Start rotating pedals backwards manually " & on display, set load setting 150 W
by pressing right pb ∆ on cycle ergometer
control panel
Manually rotate pedals backwards until
completely exhausted
3.
Complete rest (physiological parameters
after test are being recorded)
4.
Т.КТМ (end of telemetry session)
MO book 2
HEALTH MONITORING
3-36E
25-Sep-00
3.6.3. CLOSEOUT OPERATIONS
(00:10:00)
' PANEL PWR on MEDICAL EXAM PANEL
1.
LED PANEL PWR on MEDICAL EXAM PANEL
2.
connector ПКО ЭКГ-ККГ ←|→ connector EKG HARNESS
on MEDICAL EXAM PANEL
3.
' <GAMMA> MED SYS on ППС-24
4.
Dismount cycle ergometer
# [X] on cycle ergometer
control panel
5.
Doff ПКО ЭКГ-ККГ
Dry out ПКО ЭКГ-ККГ
Stow ПКО ЭКГ-ККГ
6.
Stow cycle ergometer (see МО Book 1 Sect. 5.4.3 p.5-18)
MO book 2
HEALTH MONITORING
3-37E
25-Sep-00
3.7. МО-7 MEASURING CALF VOLUME (ИЗОГ)
Purpose:
Muscle atrophy evaluation
Hardware:
Calf volume measurement kit (ИЗОГ)
Velcro Pile Strap
Measuring Tapes
Foot Strap
Figure 3.9 Calf Volume Measurement Device
NOTE
1. Perform measurements on the left leg
2. There is an individual calf volume measurement kit (ИЗОГ) for each crewmember
3. Do not overtighten ИЗОГ Velcro pile strap  just remove slack
1.
Unstow ИЗОГ measurement device
2.
Sit in any convenient location:
Ensure foot and leg are at 90° to one another
3.
Don ИЗОГ:
foot strap – under foot
zipper – on back of leg
upper edge – right under kneecap
Close zipper
4.
Wrap measuring tapes around calf and secure with Velcro (do not overtighten!)
5.
Read obtained values from the borderline between elastic and non-elastic elements
6.
Record results into Table 3.4 p. 3-39, report to MCC (during comm pass)
7.
Doff ИЗОГ and stow
MO book 2
HEALTH MONITORING
3-38E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-39E
Table 3.4
Name
Date
Tape #
Measuring tapes at different levels
1.
2.
3.
4.
5.
6.
7.
8.
Name
Date
Tape #
1.
2.
3.
4.
5.
6.
7.
8.
Measuring tapes at different levels
25-Sep-00
MO book 2
HEALTH MONITORING
3-40E
Table 3.4 (continued)
Name
Date
Tape #
Measuring tapes at different levels
1.
2.
3.
4.
5.
6.
7.
8.
Name
Date
Tape #
1.
2.
3.
4.
5.
6.
7.
8.
Measuring tapes at different levels
25-Sep-00
MO book 2
HEALTH MONITORING
3-41E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-42E
25-Sep-00
3.8. МО-8 BODY MASS MEASUREMENT
Hardware
ИМ Stand
Platform
Matching Unit (УС)
Mass Measurement Panel (УСВ)
Kit with cables
ИММ kit
3.8.1. SETUP FOR BODY MASS MEASUREMENT (ИМТ MODE)
1.
Remove platform from ИМ stand
Loosen platform locking screw
Detach platform from stand
2.
Install ИМ stand into working configuration (Figure 3.10 p. 3-42)
Locking handle (left)
Start handle (right)
ИМ Stand Neutral
Position Mark
Figure 3.10 ИМ stand in working configuration (movable part is secured in neutral position)
3.
Remove cover from ИМ stand
Temp stow cover
4.
Install platform onto ИМ stand (Figure 3.11 p. 3-43):
Rotate platform with its tailpiece towards stand's foot bar
Pivot platform onto movable tube of ИМ stand
Secure platform on ИМ stand using platform lock latches
MO book 2
HEALTH MONITORING
3-43E
25-Sep-00
Foot Bar Locking
Screw
Figure 3.11 Mass Measurement Device [ИМ] in Body Mass Measurement Configuration
[ИМТ]
5.
Disengage latches of two locking screws with latches on stand
Loosen two locking screws with latches
6.
Determine number of oscillations until complete stop:
# trigger releases of locking handles
Bring mоvable part of the stand toward its fixed base to the stop and then quickly
let it go
Count number of oscillations until complete stop
Record the number in log sheet (see pp.3-50, 3-51)
If number of oscillations <30 - wipe guiderails on the inner tube with wipe from ИММ
kit and repeat step 6
***********
* ******************************************************** *
If number of oscillations <30 see МО Book 1
Sect. 6.2.5 step 2 p. 6-35
* ******************************************************** *
Unstow cable from cable kit
Assemble configuration per Figure 3.12 p. 3-44
connector Х2 of cable 5А4.856.237 →|← РБС 10/3 power outlet
7.
8.
% РБС 10/3
MO book 2
HEALTH MONITORING
MASS MEASUREMENT
PANEL
MASS MEASUREMENT
PANEL readout
9.
3-44E
25-Sep-00
& LED PWR
& 0000
10.
**********
***********************************************************
If ) LED PWR or MASS MEASUREMENT PANEL
readout:
See MO Book 1 Sect. 6.2.5 step 1 p. 6-35
If & two-digit number on MASS MEASUREMENT
PANEL readout
See MO Book 1 Sect. 6.2.5 step 3 p. 6-35
***********************************************************
Pause for 5 min
ПКИ
cbl 5А4.856.253
ИМ
stand
ХР1
STAND
STAND
УС
cbl 5А4.856.238
УСВ
unit
У СВ
ХР1
У СВ
УС
cbl 5А4.856.237
PWR
to РБС 10/3
PWR
Figure 3.12 ИМ Stand Electrical Connection Diagram
УС
unit
MO book 2
HEALTH MONITORING
3-45E
25-Sep-00
3.8.2. BODY MASS MEASUREMENT
NOTE
1. Perform calibration prior to every first body mass measurement session
2. Repeat calibration 2-3 more times to provide more accurate measurements
3. Measure body mass only if Δ variation value <1 millisec
4. Perform calibration in case of continuous operation (over 30 min)
CALIBRATION
MASS MEASUREMENT
PANEL
ИМ stand
1.
% BODY MASS MEASUREMENT
' CALIBRATION
2.
# trigger of ИМ stand locking handle (left)
# locking (right) handle trigger release
3.
Pull device’s movable part towards its base until captured
4.
# trigger of start (right) handle
) MASS MEASUREMENT PANEL readout
" movable part oscillations (after 3 sec)
5.
" & Тпч values (oscillation period) of the next type
MASS MEASUREMENT
PANEL
ИМ stand
MASS MEASUREMENT
PANEL readout
Record obtained Тпч value in log sheet (pp. 3-50, 3-51)
6.
Repeat steps 2-5 two-three more times
MO book 2
HEALTH MONITORING
7.
3-46E
25-Sep-00
Determine ∆ variation value per formula ∆ = (Тпчmax – Тпчmin)/2
" ∆ variation value < 1millisec (1 is the least significant bit unit)
***********
* *********************************************************** *
If ∆ variation value > 1millisec:
+MCC
* *********************************************************** *
NOTE
If Δ variation value >1 millisec, it may be due to the following:
1. Oscillation measurement system of ИМ stand is not operating properly
2. ИМ stand movable part is obstructed by some factors
3. There is a significant vibration interference factor in the whole system
MEASURING BODY MASS
8.
In ИМ stand neutral position (Figure 3.10 p. 3-42)
# locking (left) trigger release
MASS MEASUREMENT
PANEL
9.
% OPERATION
10.
Install foot bars in working position:
Release locking screw (see Figure 3.11 p. 3-43)
Lower foot bars and secure in working position by tightening
locking screw
11.
Take required position on the platform:
Holding the platform's middle part, pull oneself onto it
Rest with abdomen on platform
Place feet (with platform tailpiece being between legs) on
foot bars (holding platform with hands)
Press thighs against bottom of platform and secure legs from
feet to thighs between supports and platform
Adjust the pull-out chin rest at a convenient height and
tighten locking screw to secure in position
12.
Place hands on handles (thumbs on end of handles, index
fingers – on triggers)
# triggers of ИМ stand locking (left) handle
# start (right) triggle release
MO book 2
HEALTH MONITORING
ИМ stand
Place right hand on ИМ stand base handle
Pull movable part downwards to the stop
Press chin down to the pull-out chin rest
Press oneself closer to platform, exhale, and hold breath
14.
# start (right) handle trigger
) MASS MEASUREMENT PANEL readout
" movable part oscillations (after 3 sec)
15.
& digits
Relax and resume breathing
16.
Record the obtained value in log sheet (pp. 3-50, 3-51)
17.
Repeat steps 8 - 16, pp. 3-46 – 3-47 two more times
18.
In ИМ stand neutral position, (Figure 3.10 p. 3-42),
# left trigger release
19.
Dismount platform
20.
Determine Δ variation value per formula Δ = (Mmax ― Mmin)/2
" ∆ variation value < 0.06 kg
ИМ stand
PANEL readout
25-Sep-00
13.
MASS MEASUREMENT
PANEL
MASS MEASUREMENT
3-47E
NOTE
1. Difference between obtained results should not exceed 0.06 kg
2. If otherwise, crew member’s position on ИМ stand should be corrected, or
system's own vibration interference is too high
21.
Tighten two locking screws on the ИМ stand outer tube
Engage latches on two locking screws
22.
Install foot bars into storage position:
Release locking screw (Figure 3.11 p. 3-43)
Raise foot bar and secure it in storage position, by tightening
foot bar locking screw
MO book 2
HEALTH MONITORING
3-48E
25-Sep-00
3.8.3. CLOSEOUT OPERATIONS FOR ИМТ MODE OPERATIONS
1.
' РБС 10/3
) LED PWR
cnctr Х2 cbl 5А4.856.237 $ РБС
Disassemble configuration Figure 3.12 p. 3-44
Stow cable into Kit with cables
2.
Release platform locking latches
Platform $ ИМ stand
3.
Put cover on ИМ stand (labeling is on the right)
4.
Stow ИМ stand
Stow platform on ИМ stand and secure with tightening locking
screw
MASS MEASUREMENT
PANEL
MO book 2
HEALTH MONITORING
3-49E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-50E
25-Sep-00
Log Sheet
Date:
Number of oscillation until complete stop:
Calibration
Name
Date:
Тпч1
Тпч2
Тпч3
Measurement Result
Average
M1
M2
M3
Average
Number of oscillation until complete stop:
Calibration
Name
Date:
Тпч1
Тпч2
Тпч3
Measurement Result
Average
M1
M2
M3
Average
Number of oscillation until complete stop:
Calibration
Name
Date:
Тпч1
Тпч2
Тпч3
Measurement Result
Average
М1
M2
M3
Average
Number of oscillation until complete stop:
Calibration
Name
Тпч1
Тпч2
Тпч3
Measurement Result
Average
M1
M2
M3
Average
MO book 2
HEALTH MONITORING
3-51E
25-Sep-00
Log Sheet
Date:
Number of oscillation until complete stop:
Calibration
Name
Date:
Тпч1
Тпч2
Тпч3
Measurement Result
Average
M1
M2
M3
Average
Number of oscillation until complete stop:
Calibration
Name
Date:
Тпч1
Тпч2
Тпч3
Measurement Result
Average
M1
M2
M3
Average
Number of oscillation until complete stop:
Calibration
Name
Date:
Тпч1
Тпч2
Тпч3
Measurement Result
Average
M1
M2
M3
Average
Number of oscillation until complete stop:
Calibration
Name
Тпч1
Тпч2
Тпч3
Measurement Result
Average
M1
M2
M3
Average
MO book 2
HEALTH MONITORING
3-52E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-53E
25-Sep-00
3.9. МО-9 BIOCHEMICAL URINE TEST
Used Hardware:
(CENTER) POWER UNIT
УРОЛЮКС (Urilux) unit (with pwr cbl labeled 'УРОЛЮКС-БК')
Dry wipes
УРОЛЮКС (Urilux) kit:
canister with measuring strips labeled 'Control -Test M'
paper for built-in printer
cartridge for built-in printer
УБИМ-10У kit
3.9.1. URILUX UNIT SETUP
1. Unstow unit
Secure unit at work station
2. √ printer has enough paper
If otherwise, proceed per МО Book 1 Sect.6.8.1 p.6-58
3. Assemble configuration:
cable 'УРОЛЮКС-БК'
(CENTER)
POWER
UNIT
<URILUX>
UNIT
?OUTPUT?III
Х1
Figure 3.13 Urilux Connection Diagram
(CENTER) POWER UNIT
(CENTER) CONNECTOR
CHECK
ППС-24
(CENTER) POWER UNIT
(CENTER) CONNECTOR
CHECK
4. sw VOLTAGE V → 9
sw CHECK V → 5…20
sw CHECK → POWER UNIT
sw V − Ω → V
5. % <CENTER> MED SYS
% PANEL PWR
& LED (green)
% PANEL PWR
" readout shows 09.00 ± 0.5
MO book 2
HEALTH MONITORING
3-54E
25-Sep-00
3.9.2. CHOOSING MEASURING UNITS
(if necessary)
1.
Open printer cover
2.
√ sw UNITS → lower position using pointed object (Metric System)
3.
Close printer cover
3.9.3. UNIT CALIBRATION
NOTE
1. Device УРОЛЮКС should be calibrated with the help of calibration strips
Control-Test M from УРОЛЮКС kit after its initial activation, and also every time
unit was not in operation for more than 7 days
2. Each calibration strip can be used only once
Retrieve a calibration strip from the canister just before calibration
3. Do not touch photometric (square-shaped) areas on strip with bare fingers
1. Retrieve canister labeled Control-Test M from
УРОЛЮКС kit
2. Retrieve a calibration strip from canister
Close canister
3. Open the measuring chamber cover
4. Insert a calibration strip (with gray field
upwards) into the groove on the inside of
the measuring chamber cover
MO book 2
HEALTH MONITORING
3-55E
25-Sep-00
5. Close cover of the measuring chamber (until a click is heard)
6. # pb START (on unit upper pnl) and , pb START
after printer starts operation
7. " message on the tape:
START CALIBRATION
#pb START (to initiate calibration mode)
" green LEDs light up sequentially from left to right on unit's upper panel
8. " & on all LEDs (green)
" message:
CALIBRATION OK
*************************************************
If during calibration:
& One or more red LEDs
Unit prints out the following message:
CALIBRATION ERROR
Obtain a new calibration strip
Repeat steps 2-7 p. 3-54, 3-55
If CALIBRATION ERROR message is printed again
(see Sect. 3.9.8 p. 3-61)
*************************************************
9.
Remove calibration strip from the unit and discard
MO book 2
HEALTH MONITORING
3-56E
25-Sep-00
3.9.4. URINE TEST
1.
Retrieve УБИМ-10У kit from УРОЛЮКС kit
2.
Open canister, unstow a measuring strip from canister of УБИМ-10У kit
Recap the canister (immediately)
3.
In toilet, apply urine (middle portion of void) on measuring strip squares
Blot excess urine with dry wipe to get rid of urine drops on measuring srip and reagent
zones
4.
Open measuring chamber cover
Insert measuring strip (with gray field upwards) into the groove on inside of the
measuring chamber cover
5.
Close cover until it clicks
6.
# pb START
**********
****************************************************
If no click of the lock was heard:
Open cover
Verify if the measuring strip was inserted
all the way to the stop
****************************************************
" printout:
NUMBER (sample serial number)
NAME (patient’s name)
DATE (date of test)
NOTES (additional remarks)
All necessary information on each of these fields may be also handwritten on the tape
7.
LED (preparation for measurement)
In the measurement preparation mode,
LEDs light up sequentially from left to
right (the last three LEDs glow red)
In the measuring mode, LEDs light up
sequentially from right to left
NOTE
Measurement sequence completes either automatically or upon repeated
# pb START
MO book 2
HEALTH MONITORING
3-57E
25-Sep-00
NOTE
1. If the measured values are within physiological norm, & LEDs (green)
2. If the measured values are not within the physiological norm, & LEDs (red), and
the value in question on the printout is marked with an asterisk
8.
After the printing is done:
Remove the measuring chamber cover
Discard the used measuring strip
Tear off the tape with the printout and report to MCC the first two parameters
(Sg and pH) and those marked with asterisks
3.9.5. CLOSEOUT OPERATIONS
(CENTER) POWER UNIT
(CENTER) CONNECTOR
CHECK
1.
' PANEL PWR
' PANEL PWR
' <CENTER> MED SYS
2.
Disassemble the circuit (see Figure 3.13 p. 3-53)
3.
Remove the chamber cover
Carefully, trying not to scratch optics, remove the optical
windows screen by pulling it to the right along the guiderails
4.
Wipe the chamber cover and optical windows screen (without
touching the optics) with wipe
If additional cleaning is required use tissue from Reflotron-4 Kit
to clean measurement chamber
5.
Push the optical windows screen in along the guiderails into
place with the larger windows to the left, making sure it is
installed all the way to the stop
6.
Close the chamber cover FLAP
ППС-24
Optical Windows
Screen
Large window
MO book 2
HEALTH MONITORING
3-58E
25-Sep-00
3.9.6. MEASURING CHANNEL CHECK
1.
Open printer cover and set sw UNITS into positions shown below
2.
Unstow a calibration strip from canister labeled CONTROL TEST-M
Remove cover and insert strip into measuring chamber
3.
Close FLAP
4.
# pb START (momentarily)
" the following messages are printed:
CHECK MEASUREMENT
Software Version V 1.06
Chip
1
2
3
4
5
6
7
8
9
10
11
5.
Version
UX 1.6
ХХХ
ХХХ
ХХХ
ХХХ
ХХХ
ХХХ
ХХХ
ХХХ
ХХХ
ХХХ
ХХХ
Measured parameters are considered valid if they are within the limits, shown below:
1
2
3
4
5
6
7
8
9
10
11
636-650
636-650
636-650
636-650
636-650
636-650
636-650
636-650
636-650
636-650
636-650
MO book 2
HEALTH MONITORING
3-59E
6.
Open printer cover
7.
sw UNITS → lower position using pointed object (Metric System)
8.
Close printer cover
25-Sep-00
3.9.7. MEASURING STRIP VISUAL EVALUATION
NOTE
1. In the event of irreparable failure of the unit, crew may try to visually evaluate
test parameters, using color-coded scale on the canister with measuring
strips, from УБИМ-10У kit or Combur 10 Test UX (see Figure 3.14 p. 3-60)
2. Visual evaluation must be performed in the vicinity of the table, since evaluation
accuracy greatly depends on adequate illumination of both color-coded scale
and measuring strip reagent zone
1.
Retrieve a measuring strip from canister
Immediately recap canister
2.
In toilet, apply urine (middle portion of void) on measuring strip squares
Blot excess urine with dry wipe to get rid of urine drops on measuring strip and
reagent zones
3.
Wait for 30 seconds, then bring measuring strip to the color scale on УБИМ-10У
canister
Orient the measuring strip squares against those of the color scale
(the square, nearest to crew member’s fingers, corresponds to А horizontal)
4.
Compare the coloring of reagent zones on measuring strip squares with those on
color scale
Coloring intensity assessment for parameter В should be conducted the last
Record, to which vertical group the coloring of each reagent zone on the measuring
strip corresponds (for example, А-6, Б-3, В-3, etc.)
5.
Report the obtained results to MCC in the following order:
А-Б-В-Г-Д-Е-Ж-З-И-К
MO book 2
HEALTH MONITORING
3-60E
25-Sep-00
Figure 3.14 Color scale for Visual Evaluation of Measuring Strips (Standard)
MO book 2
HEALTH MONITORING
3-61E
25-Sep-00
3.9.8. TROUBLESHOOTING
#
Probable
Cause
Every time after connection During self-check,
to power source,
performed after each
УРОЛЮКС device asks
powerup, the device
for calibration by printing
could not find any
the message START
required calibration
CALIBRATION
data
Corrective
Action(s)
Perform calibration
(see Sect 3.9.3 p. 3-54)
2.
The device prints
The calibration
CALIBRATION ERROR
characteristics are out
of the range
Make sure that screen, cover
of the measuring unit and
measuring strip of the unit
are in the correct position
Repeat calibration using a
new strip, taken out from
canister immediately
before calibration
Clean optical windows and
their screen
(see Sect 3.9.5 steps 3-6
p. 3-57)
3.
The device prints
CALIBRATION ERROR!
WARNING
See step 2 p. 3-61
4.
The device prints
CALIBRATION ERROR!
DEFECT!
1.
Symptom
Calibration strip was
inserted incorrectly or
parameters of
calibration are below
the normal values
The calibration strip is not
inserted or inserted
incorrectly;
Cover of the measuring
chamber is not closed;
The calibration
parameters are lower
than normal
See step 2 p. 3-61
Then repeat calibration
If the message
CALIBRATION ERROR!
DEFECT! is printed again,
the device may be
malfunctioning
MO book 2
HEALTH MONITORING
#
Symptom
5.
The device prints
MEASUREMENT ERROR!
3-62E
Probable
Cause
Cover of the measuring
chamber is opened
(light from the outside
gets in)
Measuring strip is not
inserted
The strip is misplaced
Crew member forgot to
moisten the strip with
urine before the test
25-Sep-00
Corrective
Action(s)
Insert measuring strip
correctly and firmly close
cover of the measuring
chamber
Repeat measurements,
using a new measuring
strip
Make sure all the reagent
areas of the measuring
strip are moistened with
urine
The strip contacted with
urine, but dried before
the test
6.
Instead of individual
parameter value, the
device prints ERROR
Reagent zone (separate
Inspect the strip
square on the
If the reagent zone is very
measuring strip) is very
dark, enter on the tape by
dark
hand "more than max."
(for example, SG > 1.030;
The measuring channel
PRO > 5g/l, etc.)
does not function
If the reagent zone coloring
is similar to that on the
canister with strips, i.e.
allows to make a
definition, the device may
not function properly
Clean optics of the device
(see Section 3.9.5 p. 3-57)
Repeat test using a new strip
The device is defective, if it
again prints ERROR
MO book 2
#
7.
8.
9.
HEALTH MONITORING
3-63E
Symptom
25-Sep-00
Probable
Cause
The device prints
The dip switches UNITS
CHECK MEASUREMENT,
are in a non-standard
the chip software version
position
number, and then threedigit codes without the
names of parameters
The device prints
Memory module (the little
CHIP ERROR
square block with a
connector), located
under the printer cover
has a poor contact
inside the connector
The memory module has
a defect
Corrective
Action(s)
Set the dip switches
into the required
position (see Sect. 3.9.2
p. 3-54)
The data provided by the
device does not match
that received visually
(i.e. discrepancy is
greater than one step of
color scale, or two steps
– for SG parameter)
Recalibrate the device;
Repeat test with a new
measuring strip;
Remove the source of
interference
Measuring strip was
inserted incorrectly
Cover of the measuring
chamber is not fully
closed
Unusual coloring
Reaction time for serial
measurements is not
observed
(see steps 2-6 on
pp. 3-61 - 3-62)
Voltage drop; cross talk
from other hardware
Disconnect the device from
the power source
# on the memory module,
to restore good contact
with the device
connectors
If the device again prints
CHIP ERROR – it is
defective: disconnect the
device from the power
source
MO book 2
#
HEALTH MONITORING
Symptom
10. The printer would not print
3-64E
25-Sep-00
Probable
Corrective
Cause
Action(s)
The device is out of paper Install a new roll
No tape in the cartridge or Replace the cartridge
the tape is too dry
No power is supplied to
the device
Check power cord and
connector connection
The printer drive does not
work
Switch the device off and on
If the problem persists, the
device is defective.
Cancel further operation
11. If the УРОЛЮКС device does not react The device can be returned to the standby
to pressing of pb START after
mode with momentary pressing pb
connection to the power source, or,
RESET located on the front panel of the
during operation, the printer motor
device under the printer cover
runs constantly, without stopping, or Pb RESET should be pressed with a long
there are any other defects
pointed object, since it is located below
the panel level
MO book 2
HEALTH MONITORING
3-65E
25-Sep-00
3.10. МО-10 DETERMINING HEMATOCRIT NUMBER
Hardware:
М-1100 kit
Reflotron-4 Kit
Battery kit
Perforator (from Reflotron-4 Accessories Kit)
Dry wipes
3.10.1. MEASURING HEMATOCRIT NUMBER
1.
2.
Unstow minicentrifuge from М-1100 kit
**********
sw POWER → ON
) red LED (under the cover)
************************************************************
If & red LED (on minicentrifuge):
Replace centrifuge batteries (Sect. 3.10.2 p. 3-68)
************************************************************
sw POWER → OFF
# on cover latch
Open minicentrifuge cover
3.
Move retainer to upper position by pressing levers to head of retainer
4.
Retrieve canister with microcapillary tubes from Reflotron-4 Kit
Temp stow canister
5.
Retrieve orange platform from Reflotron-4 Kit
Insert orange platform into perforator to stop (protrusions go into opening)
6.
Retrieve lancet from Reflotron-4 Kit pocket
Place lancet into perforator:
Take perforator in your hand
#on perforator – press to stop (to click) and hold
Place lancet into perforator (through opening in orange platform)
Uncap lancet by twisting off protective cap (do not discard cap)
, on perforator
Temp stow perforator
7.
Obtain bactericidal tissue from Reflotron-4 Kit
Treat finger tip to be punctured
Stow bactericidal tissue in Reflotron-4 Kit pocket
MO book 2
HEALTH MONITORING
3-66E
25-Sep-00
8.
Perform blood draw:
Take perforator in your hand and firmly press finger tip to orange platform of
perforator to activate the perforator trigger mechanism
Temp stow perforator
9.
If finger needs to be punctured again:
#on perforator until lancet needle appears (turn away from eyes)
Recap lancet
#on perforator to stop
Extract lancet and discard
Repeat steps 6-8 pp.3-65 - 3-66
10
Retrieve forceps from case
Using forceps, extract two microcapillary tubes from canister (detaching adhesive
tape)
Take both microcapillaries in your hand
Stow forceps back into case
11.
Squeeze out a drop of blood and blot it up using a dry wipe
Squeeze out another drop of blood
12.
Completely fill both microcapillaries with blood (make sure they do not touch each
other)
13.
Install one filled microcapillary into nominal position in the minicentrifuge:
Pressing one end into seat gasket on centrifuge tray rim,
insert other end into respective slot on the retainer
14.
Install next microcapillary in the same manner and directly opposite to the first one,
while holding the first one with finger (both are located on the same diameter of
tray)
# on retainer head
CAUTION
To avoid breaking microcapillaries, make sure they are filled
equally and are fully seated in centrifuge tray
15.
√ all microcapillaries are installed at full depth of their seats and are completely
horizontal
If otherwise, quickly move retainer to upper position and repeat steps 13-14
MO book 2
HEALTH MONITORING
3-67E
16.
Wipe finger with tissue
Cover punctured finger with bactericidal band-aid from Reflotron-4 Kit
17.
Close minicentrifuge cover to click
sw PWR (on centrifuge) → ON
25-Sep-00
) LED (red) (located under cover)
18.
After centrifuge comes to a complete stop:
sw PWR → OFF (on centrifuge)
19.
Open centrifuge cover by depressing cover release button
20.
Read markings on centrifuge plate that correspond to of red/clear interface (use
magnifier from M-1100 Kit case)
Record results in Table 3.5 p. 3-70 and report them to MCC during comm pass
21.
Retainer → to upper position
Using forceps, remove microcapillaries from minicentrifuge and discard
If necessary, clean seats with gauze or brush
Close centrifuge cover
22.
# on perforator until lancet needle appears (turn away from eyes)
Recap lancet
#on perforator to stop and remove lancet
Discard into sharps container:
lancet
orange platform
23.
Stow:
Minicentrifuge, magnifier and brush into case of М-1100 kit
Canister with microcapillaries into Reflotron-4 Kit
Discard used lancet and orange platform
Stow М 1100 kit and Reflotron-4 Kit
Place perforator into Reflotron-4 Accessories Kit
MO book 2
HEALTH MONITORING
3-68E
25-Sep-00
3.10.2. REPLACING MINICENTRIFUGE BATTERY SET
1.
Unstow minicentrifuge from case of М-1100 kit
2.
√ sw PWR → OFF
3.
Open battery compartment by sliding latches LOCK and ZU by sliding them against
arrow direction (see Figure 3.15 p. 3-68)
4.
Remove batteries from minicentrifuge battery compartment
5.
Unstow a new set of batteries
Install new batteries into minicentrifuge battery compartment (observing correct
polarity)
6.
Install batteries in minicentrifuge battery compartment
7.
Lock latches LOCK and ZU on battery compartment by sliding them in arrow
direction to stop
8.
Discard used batteries
Minicentrifuge
Power Unit
LOCK
Power Unit
Lock
ZU
Power Unit
Lock
Figure 3.15 Minicentrifuge M-1100 (Bottom View)
MO book 2
HEALTH MONITORING
3-69E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-70E
25-Sep-00
Table 3.5
Name
Date
Cap. 1
Cap. 2
Date
Cap. 1
Cap. 2
MO book 2
HEALTH MONITORING
3-71E
25-Sep-00
Table 3.5 (continued)
Name
Date
Cap. 1
Cap. 2
Date
Cap. 1
Cap. 2
MO book 2
HEALTH MONITORING
3-72E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-73E
25-Sep-00
3.11. МО-11 BIOCHEMICAL BLOOD ANALYSIS
3.11.1. INITIAL SETUP
1.
Secure at worksite:
Reflotron-4 analyzer
Reflotron-4 Kit
Canisters with Reflotron-4 measuring strips
Case with Reflotron-4 Accessories Kit
Dry wipes
2.
sw POWER → 0
3.
Retrieve power cable from Accessories Kit
4.
connector Х1 of power cable →|← connector Х1 on analyzer back panel
5.
connector Х2 of power cable →|← connector Х2 РБС 10/3
RS232
Х1
Keyboard
Х2
Х1
6.
Retrieve pipette and perforator from Accessories Kit
7.
Secure them on analyzer front panel (using Velcro)
to РБС 10/3
MO book 2
HEALTH MONITORING
3-74E
8.
Unstow a waste bag from Reflotron-4 Kit
Secure bag with Velcro on analyzer front panel
9.
% РБС 10/3
10.
sw POWER → 1
& LED (green) on analyzer front panel
11.
" sequential appearance of following messages on screen:
25-Sep-00
NOTE
1. DD.MM.YY – day, month, year
2. HH.MM.SS – hours, min, sec
3. MXX.XX CXX.XX – Manufacturer's alphanumeric code, specifying batch
number and version of software
4. Symbols ** indicate analyzer warm-up time in seconds
5. Screen messages that are listed in onboard instruction correspond to nominal
operation of analyzer
ДД.ММ.ГГ
REFLOTRON
ЧЧ:ММ:СС
МХХ.ХХ СХХ.ХХ
ДД.ММ.ГГ
ЖДИТЕ ПРОГРЕВ
12.
ЧЧ:ММ:СС
** СЕК
" after warm-up time runs out the following message appears on screen:
ДД.ММ.ГГ
ЧЧ:ММ:СС
ГОТОВ К РАБОТЕ
MO book 2
HEALTH MONITORING
3-75E
3.11.1.1. DEVICE FUNCTIONAL CHECK
1.
Retrieve CHEK canister with calibration
strips from REFLOTRON-4 Kit
Remove calibration strip from CHEK
canister, do not touch strip with
magnetic code by hands
Immediately recap canister
Restow canister
2.
Open measuring chamber cover
by depressing pb labeled FLAP
3.
" message on screen:
ДД.ММ.ГГ
ЧЧ:ММ:СС
ВСТАВЬТЕ ПОЛОСКУ
NOTE
1. Insert strip parallel to horizontal plane of the analyzer
2. Orient strip so that its gray field faces up and towards analyzer
4.
Insert calibration strip into measuring
chamber (all the way to click), making
sure switch П on the transporter has
moved to its lower position
25-Sep-00
MO book 2
5.
HEALTH MONITORING
3-76E
25-Sep-00
" message on screen:
ДД.ММ.ГГ
ЧЧ:ММ:СС
ЗАКРОЙТЕ ДВЕРЦУ
6.
Close FLAP
7.
" message on screen:
ДД.ММ.ГГ
ЧЧ:ММ:СС
ЧТЕНИЕ МАГНИТНОГО КОДА
NOTE
1. Symbols *** indicate required measuring time
2. During measurement, time is counted down
ДД.ММ.ГГ
CHEK РЕЗ ЧЕРЕЗ
8.
ЧЧ:ММ:СС
*** СЕК
" message on screen (upon completion of measurement) (symbols *** indicate
measuring results):
ДД.ММ.ГГ
ЧЧ:ММ:СС
CHEK *** *** ***
9.
Compare obtained results with data range on canister with calibration strips
Check is considered successful if data
on readout is within range specified
on canister with calibration strips
If otherwise – report to MCC
MO book 2
HEALTH MONITORING
10.
Open FLAP
by depressing pb labeled FLAP
11.
" message on screen:
3-77E
ДД.ММ.ГГ
ЧЧ:ММ:СС
УДАЛИТЕ ПОЛОСКУ
12.
While holding end of calibration strip, set switch П to upper position
13.
Remove calibration strip from measuring
chamber
14.
Discard strip into waste bag
Close FLAP
25-Sep-00
MO book 2
HEALTH MONITORING
3-78E
25-Sep-00
3.11.2. MULTIPLE-PARAMETER TEST
NOTE
1. List of measured parameters – per radiogram
2. Microvette EDTA tubes (with red cap) are used to measure HDLP cholesterol
only
3. To expedite the process, the required amount of blood is first drawn into a
Microvette tube. The following needs to be kept in mind:
- Blood collected into the Microvette tube can be used to measure all
required parameters, except hemoglobin (HB), which is measured
immediately after finger blood collection with pipette
- Glucose (GLU) and bilirubine (BIL) concentrations must be determined
within 10 minutes after blood collection into the tube
1.
Unstow pipette and perforator from Reflotron-4 Accessories Kit
2.
Unstow waste bag from Reflotron-4 Kit
Secure waste bag on analyzer
3.
Unstow canister with measuring strips for blood parameters to be measured from
Reflotron-4 Kit
4.
Open canister
Take measuring strip from canister
Close canister with cover (immediately)
Restow canister
MO book 2
HEALTH MONITORING
3-79E
25-Sep-00
NOTE
After foil is removed, hold strip by labeling area only
5.
Remove protective foil from the strip and discard foil into waste bag (if necessary)
Do not bend the strip!
6.
Insert strip into slot on measuring chamber
7.
Unstow package with pipette tips from Reflotron-4 Kit
Open pack with pipette tips
8.
Put tip on pipette
Retrieve tip from pack using pipette
9.
Secure pipette with tip on analyzer front panel
10.
Unstow orange platform from Reflotron-4 Kit
Insert orange platform into perforator to stop (protrusions go into opening)
MO book 2
HEALTH MONITORING
3-80E
25-Sep-00
11.
Unstow lancet from Reflotron-4 Kit pocket
Insert lancet into perforator:
Take perforator in hand
# on perforator to stop (until it clicks) and hold
Insert lancet into perforator (via opening on orange platform)
Remove turning protective cap on lancet (do not discard protective cap)
, on perforator
Temp stow perforator
12.
Unstow Microvette LH tube (with orange cap) from Reflotron-4 Kit
13.
Remove inner tube from holder
Tear off small orange cap, put it on tube bottom
Insert inner tube into holder
Secure tube on analyzer
14.
Retrieve from Reflotron-4 Kit:
bactericidal band-aid
bactericidal tissue
dry wipe
Secure them on analyzer
15.
Clean finger tip to be punctured (ring or middle) carefully with bactericidal tissue
Allow alcohol on finger to dry
16.
Take perforator in hand
Firmly press subject’s finger tip to orange platform to activate perforator trigger
mechanism
Secure perforator on analyzer
17.
If finger needs to be punctured again:
#on perforator until lancet needle appears (turn away from eyes)
Recap lancet
# on perforator to stop
Remove lancet and discard
Repeat steps 11, 14-16 p. 3-80
18.
Squeeze out a drop of blood
Blot it off with a dry wipe
Squeeze out another drop of blood
MO book 2
19.
HEALTH MONITORING
3-81E
25-Sep-00
Take pipette
#on pipette until some resistance can be felt (first ring
mark should be aligned with the edge of yellow ring)
Draw blood into tip by releasing pipette pushbutton slowly
and avoiding formation of air bubbles
NOTE
If air gets in the tip of the pipette, release tip content on the finger
and repeat sample collection
20.
Squeeze blood into tube (closer to thin, bottom part of tube):
# on pipette until it reaches second ring mark
21.
Repeat steps 19, 20 until tube is full
22.
Cap tube
Shake tube (thoroughly) to mix anti-coagulant with blood
Secure tube on analyzer
23.
Measure hemoglobin НВ:
Draw blood into pipette tip per step 19
Apply blood sample on measuring strip for hemoglobin НВ
Perform measurements per steps 27-37 p. 3-82 - 3-84
24.
Secure pipette on analyzer
25.
Treat puncture site with bactericidal tissue secured on analyzer see step 15 p. 3-80
Discard tissue into waste bag
Apply bactericidal band-aid to puncture site
26.
Uncap tube
Take pipette
# on pipette until some resistance can be felt (first ring mark should be aligned with
the edge of yellow ring)
Draw blood into tip by releasing pipette pushbutton slowly and avoiding formation of
air bubbles
MO book 2
HEALTH MONITORING
3-82E
25-Sep-00
NOTE
Perform step 27 p. 3-82 for not more than 10 sec
27.
Apply blood sample on measuring strip red area by pressing on pipette pushbutton
until it reaches second ring mark
Open flap by depressing pb labeled FLAP
Insert strip into chamber to click (making sure pb П on transporter moves to the lower
position)
Sample
Attachment application
area area
28.
" message on screen:
ДД.ММ.ГГ
ЧЧ:ММ:СС
ЗАКРОЙТЕ ДВЕРЦУ
29.
Close FLAP
Measuring area
MO book 2
30.
HEALTH MONITORING
3-83E
25-Sep-00
" message on screen:
ДД.ММ.ГГ
ЧЧ:ММ:СС
ЧТЕНИЕ МАГНИТНОГО КОДА
NOTE
1. Parameter encoding matches marking on canisters with strips and on
strips
2. Symbols *** indicate required measuring time
31.
" (after 4 - 5 sec) readout displays for measured parameter and time required for
measurement, for example:
ДД.ММ.ГГ
GLU РЕЗ
32.
ЧЧ:ММ:СС
ЧЕРЕЗ*** СЕК
" measurement results on display (appear upon completion of measurement
process), for example:
ДД.ММ.ГГ
GLU
5.12
ЧЧ:ММ:СС
mmol/l
NOTE
Appearance of > (greater than) and < (less than) signs signifies that value of
measured parameter lies outside measurement range of instrument
33.
Record obtained results in Table 3.6 p. 3-92
34.
Open flap by pressing pb labeled FLAP
MO book 2
HEALTH MONITORING
3-84E
25-Sep-00
35.
While holding end of measuring strip, set switch П to upper position
36.
Remove measuring strip from measuring chamber
37.
Discard measuring strip into waste bag
Close FLAP
38.
To measure other parameters, repeat steps 3-6 p. 3-78, 3-79 and steps 26-37
p. 3-81 - 3-84
39.
# on perforator until lancet needle appears (turn away from eyes)
Recap lancet
# on perforator to stop and remove lancet
Discard lancet and orange platform into waste bag
40.
Remove tip from pipette by pressing pushbutton up to stop
Discard into waste bag
Discard tube into waste bag
MO book 2
HEALTH MONITORING
3-85E
3.11.3. ONE-PARAMETER-TEST OPERATION
1.
Perform Sect. 3.11.2 steps. 1-11, 14-19, 25, 27-37 pp. 3-78 - 3-84
2.
# on perforator until lancet needle appears (turn away from eyes)
Recap lancet
# on perforator to stop and remove lancet
Discard lancet and orange platform into waste bag
3.
Remove tip from pipette by pressing pushbutton up to stop
Discard into waste bag
3.11.4. CLOSEOUT OPERATIONS
1.
√ FLAP is closed
2.
sw POWER → 0
) LED (green) on the analyzer front
panel
3.
' РБС-10/3
connector Х2 $ connector Х2 РБС-10/3
connector Х1 $ connector Х1 on the analyzer back panel
4.
Stow in Reflotron-4 Accessories Kit case:
perforator
power cable
pipette
5.
Secure Accessories Kit on analyzer
Stow:
analyzer
Reflotron-4 Kit
canisters with Reflotron-4 measuring strips
Discard waste bag
25-Sep-00
MO book 2
HEALTH MONITORING
3-86E
3.11.5. MEASURING CHAMBER CLEANUP
1.
If display is showing &:
ДД.ММ.ГГ
ЧЧ:ММ:СС
ОЧИСТКА И ПРОВЕРКА
2.
sw POWER → 0
) LED (green) on analyzer front panel
3.
Remove measuring chamber lid by
pressing pb labeled LID
4.
Retrieve a tissue from Reflotron-4 Kit
Discard packaging into waste bag
25-Sep-00
MO book 2
5.
HEALTH MONITORING
3-87E
25-Sep-00
Wipe with single tissue:
photometer
magnetic head
heater with transporter
Discard tissue into waste bag
Photometer
Magnetic
head
Heater with
transporter
6.
Let analyzer dry for 15 min
7.
Reinstall measuring chamber lid until it
clicks in place
8.
Repeat analyzer functional check using calibration strip СНЕК per Sect. 3.11.1.1
p. 3-75
MO book 2
HEALTH MONITORING
3-88E
25-Sep-00
3.11.6. LIST OF READOUT MESSAGES AND TROUBLESHOOTING
Message
20.09.96
Meaning of Message
12.09.56
Check of analyzer's functionality
REFLOTRON MXX.XX.CXX.XX
12.09.56 Time required for analyzer to
20.09.96
warm up
ЖДИТЕ ПРОГРЕВ 180 сек
12.09.56
20.09.96
Analyzer is ready to operate
ГОТОВ К РАБОТЕ
20.09.96
12.09.56
FLAP is open
Crew member actions
Not required
Allow analyzer to warm up
Start blood test
Insert measuring strip
ВСТАВЬТЕ ПОЛОСКУ
20.09.96
12.09.56
ЗАКРОЙТЕ ДВЕРЦУ
20.09.96
12.09.56
ЧТЕНИЕ МАГНИТНОГО КОДА
20.09.96
12.09.56
GLU РЕЗ.
20.09.96
GLU
20.09.96
Magnetic code is being read
Magnetic code has been read
correctly
Result of measurement
Close measuring chamber
cover
Not required
Wait for result
Record result
5.12 mmo/l
12.09.56
GLU <
20.09.96
GLU
ЧЕРЕЗ 143 СЕК
12.09.56
Measuring strip is inserted
correctly but cover latch is in
wrong position
0.56 mmol/l
12.09.56
>
Repeat measurement
The result is off-scale high
Repeat measurement
Result for enzymes,
temperature is also
specified
Record result
Nature of kinetic reaction is
somewhat different from
linear
Repeat measurement strictly
following recommended
procedure
33.3 mmol/l
20.09.96
GGT
31.0
20.09.96
GGT
200
The result is off-scale low
12.09.56
U/l
U/l
37°°C
12.09.56
37°°C
⇓
20.09.96
12.09.56
НЕЛИНЕЙНАЯ РЕАКЦИЯ!
MO book 2
HEALTH MONITORING
Message
3-89E
Meaning of the message
20.09.96
12.09.56
Nature of kinetic reaction is
НЕВЕРНЫЙ РЕЗУЛЬТАТ!
significantly different from
⇓
linear
20.09.96
12.09.56
НЕЛИНЕЙНАЯ РЕАКЦИЯ!
20.09.96
12.09.56
Kinetic reaction linearity can not
GGT
200
U/l
37°°C
be checked
⇓
20.09.96
12.09.56
ПАРАМЕТР ВНЕ ПРЕДЕЛА!
Unit of measurement or
NO PARAMETER
temperature cannot be
determined because strip
to be measured is not
present
НЕТ ДАННЫХ!
20.09.96
12.09.56
УДАЛИТЕ ПОЛОСКУ
No more records in buffer
Used measuring strip was left
in chamber
20.09.96
12.09.56 After chamber was closed,
НЕТ МАГНИТНОГО КОДА!
analyzer could not read
magnetic code
20.09.96
12.09.56
НЕВЕРНО СЧИТАН МАГ. КОД!
20.09.96
12.09.56
ИЗМЕРЕНИЕ ПРЕРВАНО!
After
20.09.96
12.09.56
ЗАКРОЙТЕ ДВЕРЦУ
20.09.96
12.09.56
ИЗМЕРЕНИЕ ПРЕРВАНО!
After
20.09.96
12.09.56
УДАЛИТЕ ПОЛОСКУ
Magnetic code is incomplete or
damaged
25-Sep-00
Crew member actions
Repeat measurement strictly
following recommended
procedure
Repeat measurement strictly
following recommended
procedure
Insert strip
Proceed after ГОТОВ К
РАБОТЕ (ready to
operate) message appears
Remove used measuring
strip
Insert measuring strip with
magnetic layer facing
downward, red field first
Replace measuring strip
The measurement is halted
because the chamber has
been opened during
measurement
Close chamber and wait for
next message
The measurement is halted
because the chamber has
been opened during
measurement
Open chamber and remove
measuring strip
MO book 2
HEALTH MONITORING
3-90E
Message
Meaning of the message
20.09.96
12.09.56 Measuring chamber needs to be
ОЧИСТКА И ПРОВЕРКА!
cleaned
More than 7 days have passed
or more than 100
20.09.96
12.09.56
measurements have been
ВСТАВЬТЕ CHECK
performed since latest
ПОЛОСКУ!
analyzer functional check
ПРИБОРУ ЖАРКО!
Temperature outside measuring
chamber is too high
25-Sep-00
Crew member actions
Clean the chamber
(see Sect. 3.11.5
p. 3-86)
Check functionality of
analyzer using CHECK
measuring strip
(see Sect. 3.11.1.1
p. 3-75)
Inspect analyzer’s vent
screen and measure
ambient temperature
Relocate the device to a
cooler location
ПРИБОРУ ХОЛОДНО!
Temperature outside measuring
chamber is too low
ERROR DDDD
Problem can only be eliminated
by expert
Не горит зеленый СвД
питания
Power is off
Before resuming operation,
cool down analyzer
Transfer analyzer to a warmer
location (15 – 32ОС)
Before resuming operation,
warm up analyzer
Power cycle analyzer
If message persists, report to
MCC
Check power cable
connections
MO book 2
HEALTH MONITORING
3-91E
For notes
25-Sep-00
MO book 2
HEALTH MONITORING
3-92E
Table 3.6 Results of biochemical parameters analysis (Reflotron-4)
NAME
Date
GLU
HB
CHOL
TG
UREA
GGT
UA
GOT
GPT
BIL
AMYL
CREA
CK
P - AM
HDLP
NAME
Date
GLU
HB
CHOL
TG
UREA
GGT
UA
GOT
GPT
BIL
AMYL
CREA
CK
P - AM
HDLP
25-Sep-00
MO book 2
HEALTH MONITORING
Table 3.6 (continued)
NAME
Date
GLU
HB
CHOL
TG
UREA
GGT
UA
GOT
GPT
BIL
AMYL
CREA
CK
P - AM
HDLP
NAME
Date
GLU
HB
CHOL
TG
UREA
GGT
UA
GOT
GPT
BIL
AMYL
CREA
CK
P - AM
HDLP
3-93E
25-Sep-00
MO book 2
HEALTH MONITORING
3-94E
For notes
25-Sep-00
МО Book 2
Control of Environment
4-1E
25-Sep-00
4. CONTROL OF ENVIRONMENT
4.1. МО-21 CONTROL OF ENVIRONMENT MICROECOSPHERA
Hardware:
ЭКОСФЕРА (Ecosphera)Sampler Kit:
Air sampler
Charging unit
БП ЭКОСФЕРА (Ecosphera power supply unit - battery)
Tray for Petri dish storage
Ecosphera cable (Хт.6.644.605)
(CENTER) POWER UNIT (ЦЕНТР МЭК-2 Kit)
Ecosphera kit:
Petri dishes with MEDIA 1 (8 ea. + 2 spares)
Petri dishes with MEDIA 2 (8 ea. + 2 spares)
Experiment Timeline:
Day of experiment
Crew members’ actions
Charging of Ecosphera battery (charge time ∼ 8
hours)
Installation of KRIOGEM-03 refrigerator (if
necessary), see MO Book 1 Sect. 7.1.1
p. 7-4
Time spent by
crew
20 min
20 min
1 hour prior to
sample collection
Activation of KRIOGEM-03 refrigerator in mode
+37°C, see MO Book 1 Sect. 7.1.3 p. 7-5
T.0
Microflora sample collection and sample with
MEDIA 1 placement for incubation in refrigerator
50 min
T.0 + 2 days
Evaluation of test results of bacteria microflora in
Petri dishes for MEDIA 1
40 min
T.0 + 7 days
Evaluation of test results of fungus in Petri dishes
for MEDIA 2
40 min
МО Book 2
Control of Environment
4-2E
25-Sep-00
4.1.1. SETUP
4.1.1.1. CHARGING БП ЭКОСФЕРА (ECOSPHERA BATTERY)
NOTE
Charging time is 8 hours
(CENTER) POWER UNIT
1.
Unstow:
ЦЕНТР МЭК-2 kit with cables
ЭКОСФЕРА sampler set
Retrieve cable # 1 ЦЕНТР from ЦЕНТР МЭК-2 kit
2.
Assemble circuit to charge БП ЭКОСФЕРА battery
3.
sw VOLTAGE → 9
sw CHECK → 5…20
sw CHECK → POWER UNIT
sw V − Ω → V
4.
! <CENTER> MED SYS
! PANEL PWR
! PANEL PWR
(CENTER) CONNECOR
CHECK
ППС-24
(CENTER) POWER UNIT
(CENTER) CONNECOR
CHECK
Ecospera charger
" LED green
" LED (red)
5.
(CENTER) POWER UNIT
After charging is complete (in 8 hours):
(CENTER) CONNECOR
CHECK
# PANEL PWR
$ LED (red)
# PANEL PWR
ППС-24
# <CENTER> MED SYS
Ecospera charger
6.
Disassemble configuration and restow hardware
МО Book 2
Control of Environment
4-3E
25-Sep-00
4.1.2. TEST PERFORMANCE
4.1.2.1. HARDWARE ACTIVATION
NOTE
1. Air sampling is performed by one operator in discretionary order
2. Sampling locations are specified in Table on case cover, or per MCC instruction
1.
Unstow ЭКОСФЕРА Sampler Kit
2.
Remove from the kit:
Air sampler
БП ЭКОСФЕРА battery
Ecosphera cable
3.
Secure БП ЭКОСФЕРА battery to air sampler body using
Velcro
4.
cnctr X3 of Ecosphera cable →|← connector X3 on air sampler
cnctr X2 of Ecosphera cable →|← connector X2 on БП
ЭКОСФЕРА battery
5.
Remove plastic cover from nozzle screen
Stow nozzle screen in ЭКОСФЕРА Sampler Kit
6.
Configure controls on air sampler back panel as follows:
! ВКЛ (On)
" LED (under the switch)
sw РАСХОД → 1
7.
Place air sampler in left hand, put strap over hand
8.
Hold sampler with nozzle screen facing away
00:00:00
9.
% pb ПУСК (on control panel)
& motor is running
00:00:20
10.
& motor stops
# ВЫКЛ (Off)
$ LED (under the switch)
МО Book 2
Control of Environment
4-4E
25-Sep-00
4.1.2.2. MICROFLORA SAMPLE COLLECTION
CAUTION
1. If mold and bacteria are detected on surfaces, perform sample collection in this
area in addition to scheduled area
Report new air sample collection area to MCC
2. When performing sample collection, do not touch media surface with fingers
1.
sw РАСХОД → 3 (on control panel)
2.
Unstow ЭКОСФЕРА Kit
3.
Take ЭКОСФЕРА Kit and air sampler to first sample collection area
4.
Unscrew ' nozzle screen
Secure nozzle screen to sampler body using Velcro
5.
Remove Petri dish with MEDIA 1 from ЭКОСФЕРА Kit
МО Book 2
Control of Environment
4-5E
25-Sep-00
CAUTION
Petri dish number should match sampling location number
OPERATION А:
6.
Open package
Retrieve Petri dish
Discard package
Write sample collection location on the lid (if necessary)
7.
Place Petri dish on base of sampler collection element with lid facing outside
8.
Remove lid from Petri dish
Place lid in suit pocket
9.
Attach nozzle screen to base of sample collection element by turning (
Hold sampler at chest level with nozzle screen facing away
10.
% pb ПУСК (on control panel)
LED (under the switch)
&Motor is operating
11.
& (∼60 sec) motor stops
12.
After motor stops:
Rotate ) nozzle screen
Remove nozzle screen and secure it to sampler body with Velcro
Place lid on contact plate of Petri dish
Detach Petri dish from the base of sample collection element
Stow Petri dish back in ЭКОСФЕРА Kit
13.
Remove Petri dish with MEDIA 2 from ЭКОСФЕРА Kit
Repeat operation A with Petri dish with MEDIA 2, do not discard Petri dish
packages and later on use them for stowage of Petri dishes with samples
14.
After completion of sample collection in one area, go to another sampling location
In each location, perform sample collection to corresponding Petri dishes with
MEDIA 1 and MEDIA 2
МО Book 2
Control of Environment
4-6E
25-Sep-00
4.1.2.3. CLOSEOUT OPERATIONS
After concluding sample collection in last sampling location, perform closeout steps:
1.
# ВЫКЛ (on control panel)
2.
Disassemble circuit and stow cable
3.
Detach БП ЭКОСФЕРА battery from sampler
4.
Attach plastic cover to sampler nozzle screen
5.
Attach nozzle screen to base of sample collection element by turning (
6.
Place in ЭКОСФЕРА sampler kit:
БП ЭКОСФЕРА battery
Ecosphera cable
Air sampler
7.
Place Petri dishes with samples collected with MEDIA 1 into cassette
8.
Place cassette in KRIOGEM-03 refrigerator (for 48 hrs at +37°С) or place cassette in
warmer place per crew discretion
9.
Place Petri dishes with collected samples with MEDIA 2 into Ecosphera kit for 7 days
(stowed at ambient temperature)
10.
Stow sampler kit
$ LED (under the switch)
МО Book 2
Control of Environment
4-7E
25-Sep-00
4.1.2.4. EVALUATION OF TEST RESULTS
Microorganisms settled from air onto media will produce growth of various colonies
Number of colonies indicates air contamination level
The results are interpreted by the operator, if necessary, they may be videotaped
and downlinked to MCC
When videotaping, view Petri dishes through bottom against light and then under the
same light source in reflected light
NOTE
1. In Petri dishes with MEDIA 1, grown colony count is performed 2 days after
sample collection
2. In Petri dishes with MEDIA 2, grown colony count is performed 7 days after
sample collection
4.1.2.5. TOTAL COLONY COUNT
NOTE
Perform colony count at the table near a light source
1.
Remove Petri dish with collected samples from cassette
2.
Place Petri dish 20-30 cm away from eye level
3.
Without opening lid, view Petri dish against light through the bottom (of contact plate)
4.
Without opening lid, view Petri dish in reflected light from lid side
5.
Count and classify colonies by type (to simplify counting, each colony can be marked
with felt-tip pen)
6.
Record obtained results in Table 4.1 p. 4-10
7.
Repeat counting and classification of colonies of microorganisms for all Petri dishes
8.
When results logging is complete:
Discard Petri dishes
Stow cassette in ЭКОСФЕРА Sampler Kit
МО Book 2
Control of Environment
4-8E
25-Sep-00
4.1.2.6. COLONY CLASSIFICATION IN PETRI DISHES WITH MEDIA 1
Resulting colonies may be of different types:
Sporoformic bacillus:
large (3-6 mm and larger), irregular-form colonies, appear as a membrane with
uneven, wrinkled or vesicular surface, gray or yellowish in color (see Figure 4.1
p. 4-13)
Coryneformic bacteria:
Small (to 1 mm), flat, gray matte colonies (see Figure 4.2 p. 4-14)
Gram-negative bacteria:
Medium size (1-3 mm), round, protruding, slimy or watery colonies
Have smooth shiny surface, whitish-gray or yellowish color (see Figure 4.3
p. 4-14)
4.1.2.7. COLONY CLASSIFICATION IN PETRI DISHES WITH MEDIUM 2
Resulting colonies may be of different types:
Dark-colored fungi may have the following color:
Brownish-red, dark-olive, dark ashen, green-black
and black (see Figure 4.4 p. 4-15, Figure 4.5 p. 4-16)
Light-colored fungi may have the following color:
Gray, grayish-green, green, bluish, yellow, brown-pink,
orange-pink and orange-red (see Figure 4.6 - Figure 4.12 p. 4-17 - 4-23)
4.1.2.8. DOWNLINK INFORMATION
The operator reports the test results during comm pass in the following format:
ID# of sampling location
Number of microorganisms /fungi/ in sample in the same order as recorded in
corresponding columns of Table 4.1 p. 4-10
Example of reported data:
3 А25, 3 Б0, 3 В15, 3 Г10, 3 Д20, 3 Е15, 3 Ж5
If the data is videotaped, it needs to be downlinked to MCC
МО Book 2
Control of Environment
For notes
4-9E
25-Sep-00
МО Book 2
Control of Environment
4-10E
25-Sep-00
Table 4.1 RECORD OF TEST RESULTS
MEDIA 1
Microflora
sampling
locations
Total
Number of
number of sporoformic
microor- bacilli
ganisms
in sample
А
MEDIA 2
Number
of gramnegative
bacilli
Б
В
Number of
coryneformic
bacteria
Г
Total
number
of fungi
Д
Number of
lightcolored
fungi
Е
Number of
darkcolored
fungi
Ж
Location #1
Location # 2
Location # 3
Location #4
Location # 5
Location # 6
Table 4.1 RECORD OF TEST RESULTS
MEDIA 1
Microflora
sampling
locations
Total
Number of
number of sporoformic
microor- bacilli
ganisms
in sample
А
Location #1
Location # 2
Location # 3
Location #4
Location # 5
Location # 6
Б
MEDIA 2
Number
of gramnegative
bacilli
В
Number of
coryneformic
bacteria
Г
Total
number
of fungi
Д
Number of
lightcolored
fungi
Е
Number of
darkcolored
fungi
Ж
МО Book 2
Control of Environment
4-11E
25-Sep-00
Table 4.1 RECORD OF TEST RESULTS
MEDIA 1
Microflora
sampling
locations
Total
Number of
number of sporoformic
microor- bacilli
ganisms
in sample
А
MEDIA 2
Number
of gramnegative
bacilli
Б
В
Number of
coryneformic
bacteria
Г
Total
number
of fungi
Д
Number of
lightcolored
fungi
Е
Number of
darkcolored
fungi
Ж
Location #1
Location # 2
Location # 3
Location #4
Location # 5
Location # 6
Table 4.1 RECORD OF TEST RESULTS
MEDIA 1
Microflora
sampling
locations
Total
Number of
number of sporoformic
microor- bacilli
ganisms
in sample
А
Location #1
Location # 2
Location # 3
Location #4
Location # 5
Location # 6
Б
MEDIA 2
Number
of gramnegative
bacilli
В
Number of
coryneformic
bacteria
Г
Total
number
of fungi
Д
Number of
lightcolored
fungi
Е
Number of
darkcolored
fungi
Ж
МО Book 2
Control of Environment
For notes
4-12E
25-Sep-00
МО Book 2
Control of Environment
4-13E
TYPE А
TYPE Б
Figure 4.1. Sporoformic bacillus
25-Sep-00
МО Book 2
Control of Environment
4-14E
Figure 4.2. Coryneformic bacteria
Figure 4.3. Gram-negative bacteria
25-Sep-00
МО Book 2
Control of Environment
4-15E
TYPE А (as viewed through lid)
TYPE А (as viewed through bottom)
Figure 4.4 Dark-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-16E
TYPE Б (as viewed through lid)
TYPE Б (as viewed through bottom)
Figure 4.5 Dark-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-17E
TYPE А (as viewed through lid)
TYPE А (as viewed through bottom)
Figure 4.6 Light-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-18E
TYPE Б (as viewed through lid)
TYPE Б (as viewed through bottom)
Figure 4.7 Light-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-19E
TYPE В (as viewed through lid)
ТИП В (as viewed through bottom)
Figure 4.8 Light-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-20E
TYPE Г (as viewed through lid)
TYPE Г (as viewed through bottom)
Figure 4.9 Light-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-21E
TYPE Д (as viewed through lid)
TYPE Д (as viewed through bottom)
Figure 4.10 Light-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-22E
TYPE Е (as viewed through lid)
TYPE Е (as viewed through bottom)
Figure 4.11 Light-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-23E
TYPE Ж (as viewed through lid)
TYPE Ж (as viewed through bottom)
Figure 4.12 Light-colored fungi
25-Sep-00
МО Book 2
Control of Environment
4-24E
25-Sep-00
4.2. МО-22 SANITARY-EPIDEMIOLOGICAL STATUS MONITORING
Hardware:
Kit with test tubes (for hardware surfaces)
Kit with test tubes (for crew member)
CAUTION
When collecting samples, do not touch capillary tube walls and cotton swab
with bare fingers in order to prevent sample contamination
1. Unscrew one tube lid and remove cotton swab from test tube
Collect microflora sample (collection locations are indicated on kit pocket flap next to
each test tube)
2. Insert lid with cotton swab into test tube
Close lid firmly
3. Label crewmember’s name on kit with test tubes
4. Stow test tubes with collected samples in relevant kit
Stow kit
МО book 2
Questionary
5-1E
5. QUESTIONARY
5.1. PHS (30 DAY PHYSICAL EVALUATION)
NOTE
Steps 17, 23, 24, 31 are performed per clinical indications
Clinical Evaluation:
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Respiratory Rate
4
Body temperature (Celsius)
5
Peak Flow
6
Medications Taken
7
No
1
Yes (report FS via PMC)
2
Complaints
No
1
Yes (report FS via PMC)
2
8
Sleep Duration (hours)
9
Quality of Sleep
10
Normal Deep (sound),
uninterrupted
Interrupted
1
Insomnia
3
2
Fatigue
Absent
1
Occurs at end of day,
relieved with sleep
Not relieved with sleep
2
3
25-Sep-00
МО book 2
11
12
13
14
15
16
Questionary
5-2E
Appetite
Normal
1
Increased
2
Decreased
3
Absent
4
Water/Liquid Consumption
Normal (usual)
1
Increased
2
Decreased
3
Absent
4
Nose
Normal
1
Congestion
2
Discharge
3
Bleeding
4
Mouth and Throat
Normal
1
Swelling
2
Redness
3
Changes in Tonsils
4
Dental/Gums
Normal
1
Tenderness
2
Swelling
3
Redness
4
Cracked/Loose Teeth
5
Ears-General
Normal
1
Drainage
2
Redness
3
Wax Buildup
4
25-Sep-00
МО book 2
17
18
19
20
21
Questionary
5-3E
Ears-Tympanic Membrane
Normal
1
Redness
2
Deformation
3
Perforated
4
Fluid
5
Bloody
6
No movement w/Valsalva
7
Eyes-Lids
Normal
1
Redness
2
Swelling
3
Lesion
4
Droopy Eyelid (Ptosis)
5
Crusting
6
Swelling around eyes
(Periorbital Edema)
Itch
7
8
Eyes- Conjunctiva
Normal
1
Redness
2
Hemorrhage
3
Tearing
4
Dryness
5
Eyes-Cornea
Normal
1
Scar
2
Cloudy
3
Eyes-Pupils
Normal
1
Dilated
2
Constricted
3
Unequal size
4
Unreactive to light
5
25-Sep-00
МО book 2
22
23
Normal
1
Nystagmus
2
Asymmetry
3
Eyes-Opthalmoscopic/Retina
Normal
1
Hemorrhage
2
Other lesions
3
Eyes-IOP
25
Neck
27
28
29
5-4E
Eyes-Ocular Motility
24
26
Questionary
Normal
1
Enlarged lymph nodes
2
Enlarged veins
3
Chest
Normal
1
Asymmetric appearance
2
Asymmetric movement
3
Shallowing breathing
4
Deep breathing
5
Lungs
Normal
1
Coarse breath sounds
2
Decreased/Weak Respiration
3
Crackles
4
Wheezing
5
Rales (fluid sounds)
6
Heart
Normal
1
Murmur
2
Irregular
3
Vascular System-Pulse
Normal
1
Weak
2
Intense
3
Irregular
4
Asymmetric
5
25-Sep-00
МО book 2
30
Questionary
Abdomen
1
Normal
Bowel
Sounds
(Peristalsis)
31
32
33
34
5-5E
Increased
2
Decreased
3
Pain on palpation
4
Rigid abdomen
5
Mass
6
Genito-Urinary
Normal
1
Discharge
2
Tenderness
3
Upper Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
Lower Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
Spine/Musculoskeletal
Normal
1
Decreased ROM
2
Pain on palpation of spine
3
25-Sep-00
МО book 2
35
36
Questionary
5-6E
Skin, Lymphatic
Normal
1
Redness
2
Pale
3
Rash
4
Itch
5
Abrasions
6
Lacerations
7
Bruising
8
Burns
9
Skin infection
10
Enlarged nodes
11
Tender nodes
12
Neuromuscular Exam
Finger to Nose test
Normal
1
Miss
2
25-Sep-00
МО book 2
Questionary
5-7E
NOTE.
Steps 17, 23, 24, 31 are performed per clinical indications
Clinical Evaluation:
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Respiratory Rate
4
Body temperature (Celsius)
5
Peak Flow
6
Medications Taken
7
No
1
Yes (report FS via PMC)
2
Complaints
No
1
Yes (report FS via PMC)
2
8
Sleep Duration (hours)
9
Quality of Sleep
10
Normal Deep (sound),
uninterrupted
Interrupted
1
Insomnia
3
2
Fatigue
Absent
1
Occurs at end of day,
relieved with sleep
Not relieved with sleep
2
3
25-Sep-00
МО book 2
11
12
13
14
15
16
Questionary
5-8E
Appetite
Normal
1
Increased
2
Decreased
3
Absent
4
Water/Liquid Consumption
Normal (usual)
1
Increased
2
Decreased
3
Absent
4
Nose
Normal
1
Congestion
2
Discharge
3
Bleeding
4
Mouth and Throat
Normal
1
Swelling
2
Redness
3
Changes in Tonsils
4
Dental/Gums
Normal
1
Tenderness
2
Swelling
3
Redness
4
Cracked/Loose Teeth
5
Ears-General
Normal
1
Drainage
2
Redness
3
Wax Buildup
4
25-Sep-00
МО book 2
17
18
19
20
21
Questionary
5-9E
Ears-Tympanic Membrane
Normal
1
Redness
2
Deformation
3
Perforated
4
Fluid
5
Bloody
6
No movement w/Valsalva
7
Eyes-Lids
Normal
1
Redness
2
Swelling
3
Lesion
4
Droopy Eyelid (Ptosis)
5
Crusting
6
Swelling around eyes
(Periorbital Edema)
Itch
7
8
Eyes- Conjunctiva
Normal
1
Redness
2
Hemorrhage
3
Tearing
4
Dryness
5
Eyes-Cornea
Normal
1
Scar
2
Cloudy
3
Eyes-Pupils
Normal
1
Dilated
2
Constricted
3
Unequal size
4
Unreactive to light
5
25-Sep-00
МО book 2
22
23
Normal
1
Nystagmus
2
Asymmetry
3
Eyes-Opthalmoscopic/Retina
Normal
1
Hemorrhage
2
Other lesions
3
Eyes-IOP
25
Neck
27
28
29
5-10E
Eyes-Ocular Motility
24
26
Questionary
Normal
1
Enlarged lymph nodes
2
Enlarged veins
3
Chest
Normal
1
Asymmetric appearance
2
Asymmetric movement
3
Shallowing breathing
4
Deep breathing
5
Lungs
Normal
1
Coarse breath sounds
2
Decreased/Weak Respiration
3
Crackles
4
Wheezing
5
Rales (fluid sounds)
6
Heart
Normal
1
Murmur
2
Irregular
3
Vascular System-Pulse
Normal
1
Weak
2
Intense
3
Irregular
4
Asymmetric
5
25-Sep-00
МО book 2
30
Questionary
Abdomen
1
Normal
Bowel
Sounds
(Peristalsis)
31
32
33
34
5-11E
Increased
2
Decreased
3
Pain on palpation
4
Rigid abdomen
5
Mass
6
Genito-Urinary
Normal
1
Discharge
2
Tenderness
3
Upper Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
Lower Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
Spine/Musculoskeletal
Normal
1
Decreased ROM
2
Pain on palpation of spine
3
25-Sep-00
МО book 2
35
36
Questionary
5-12E
Skin, Lymphatic
Normal
1
Redness
2
Pale
3
Rash
4
Itch
5
Abrasions
6
Lacerations
7
Bruising
8
Burns
9
Skin infection
10
Enlarged nodes
11
Tender nodes
12
Neuromuscular Exam
Finger to Nose test
Normal
1
Miss
2
25-Sep-00
МО book 2
Questionary
5-13E
5.2. PRE-EVA EXAMS
PHS-pre-EVA-1 (Is conducted 1-2 days prior to EVA)
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Respiratory Rate
4
Temperature Celsius
5
Medications Taken
6
No
1
Yes (report FS via PMC)
2
Complaints
No
1
Yes (report FS via PMC)
2
7
Sleep Duration (hours)
8
Quality of Sleep
9
10
11
Normal Deep(sound),
uninterrupted
Interrupted
1
Insomnia
3
2
Fatigue
Absent
1
Occurs at end of day,
relieved with sleep
Not relieved with sleep.
2
3
Nose
Normal
1
Congestion
2
Discharge
3
Bleeding
4
Mouth and Throat
Normal
1
Swelling
2
Redness
3
Changes in Tonsils
4
25-Sep-00
МО book 2
12
13
Questionary
5-14E
Ears-Tympanic Membrane
Normal
1
Redness
2
Deformation
3
Perforated
4
Fluid
5
Bloody
6
No movement w/Valsalva
7
Skin
Normal
1
Redness
2
Pale
3
Rash
4
Itch
5
Abrasions,
6
Lacerations
7
Bruising
8
Burns
9
Skin infection
10
PHS-pre-EVA-2 (Is conducted per day EVA)
1. Clinical Evaluation
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Respiratory Rate
4
Temperature Celsius
2. BMM – The onboard instruction МО book 2, Sec. 3.8 page 3-42
3. Urinalysis - The onboard instruction МО book 2, Sec. 3.9 page 3-53
25-Sep-00
МО book 2
Questionary
5-15E
PHS-pre-EVA-1 (Is conducted 1-2 days prior to EVA)
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Respiratory Rate
4
Temperature Celsius
5
Medications Taken
6
No
1
Yes (report FS via PMC)
2
Complaints
No
1
Yes (report FS via PMC)
2
7
Sleep Duration (hours)
8
Quality of Sleep
9
10
11
Normal Deep(sound),
uninterrupted
Interrupted
1
Insomnia
3
2
Fatigue
Absent
1
Occurs at end of day,
relieved with sleep
Not relieved with sleep.
2
3
Nose
Normal
1
Congestion
2
Discharge
3
Bleeding
4
Mouth and Throat
Normal
1
Swelling
2
Redness
3
Changes in Tonsils
4
25-Sep-00
МО book 2
12
13
Questionary
5-16E
Ears-Tympanic Membrane
Normal
1
Redness
2
Deformation
3
Perforated
4
Fluid
5
Bloody
6
No movement w/Valsalva
7
Skin
Normal
1
Redness
2
Pale
3
Rash
4
Itch
5
Abrasion
6
Lacerations
7
Bruising
8
Burns
9
Skin infection
10
PHS-pre-EVA-2 (Is conducted per day EVA)
1. Clinical Evaluation
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Respiratory Rate
4
Temperature Celsius
2. BMM – The onboard instruction МО book 2, Sec. 3.8 page 3-42
3. Urinalysis - The onboard instruction МО book 2, Sec. 3.9 page 3-53
25-Sep-00
МО book 2
Questionary
5-17E
25-Sep-00
5.3. POST-EVA EXAMS
PHS-post-EVA-1 (Is conducted at once after EVA-suit doffing)
1. Clinical Evaluation
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Skin
Normal
1
Redness
2
Pale
3
Rash
4
Abrasions
5
Lacerations
6
Bruising
7
Nail trauma
8
NOTE
If clinically indicated, perform fool exam PHS-post-EVA-2 (see page 5-18)
МО book 2
Questionary
5-18E
PHS-post-EVA-2 (Is performed only is clinically indicated)
Clinical Evaluation
4
Respiratory Rate
5
Temperature Celsius
6
Complaints
7
8
9
10
No
1
Yes (report FS via PMC)
2
Nose
Normal
1
Congestion
2
Discharge
3
Bleeding
4
Mouth and Throat
Normal
1
Swelling
2
Redness
3
Lesions
4
Ears-General
Normal
1
Drainage
2
Redness
3
Wax Buildup
4
Ears-Tympanic Membrane
Normal
1
Redness
2
Deformation
3
Perforated
4
Fluid
5
Bloody
6
No movement w/Valsalva
7
25-Sep-00
МО book 2
11
12
13
14
15
Questionary
5-19E
Eyes-Lids
Normal
1
Redness
2
Swelling
3
Lesion
4
Itch
5
Crusting
6
Swelling around eyes
(Periorbital Edema)
7
Eyes- Conjunctiva
Normal
1
Redness
2
Hemorrhage
3
Tearing
4
Dryness
5
Chest
Normal
1
Asymmetric appearance
2
Asymmetric movement
3
Shallowing breathing
4
Deep breathing
5
Lungs
Normal
1
Coarse breath sounds
2
Decreased/Weak
Respiration
Crackles
3
Wheezing
5
Rales (fluid sounds)
6
4
Heart
Normal
1
Murmur
2
Irregular
3
25-Sep-00
МО book 2
16
17
Questionary
5-20E
Upper Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
Lower Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
2. BMM – The onboard instruction МО Book 2 Sec. 3.8 page 3-42
3. Urinalysis - The onboard instruction МО Book 2 Sec. 3.9 page 3-53
25-Sep-00
МО book 2
Questionary
5-21E
25-Sep-00
PHS-post-EVA-1 (Is conducted at once after EVA-suit doffing)
1. Clinical Evaluation
Date
Time
Crewmember’s ID
Examiner’s ID
1
Blood Pressure
2
Pulse
3
Skin
Normal
1
Redness
2
Pale
3
Rash
4
Abrasions
5
Lacerations
6
Bruising
7
Nail trauma
8
NOTE
If clinically indicated, perform fool exam PHS-post-EVA-2 (see page 5-22)
МО book 2
Questionary
5-22E
PHS-post-EVA-2 (Is performed only is clinically indicated)
Clinical Evaluation
4
Respiratory Rate
5
Temperature Celsius
6
Complaints
7
8
9
10
No
1
Yes (report FS via PMC)
2
Nose
Normal
1
Congestion
2
Discharge
3
Bleeding
4
Mouth and Throat
Normal
1
Swelling
2
Redness
3
Lesions
4
Ears-General
Normal
1
Drainage
2
Redness
3
Wax Buildup
4
Ears-Tympanic Membrane
Normal
1
Redness
2
deformation
3
Perforated
4
Fluid
5
Bloody
6
No movement w/Valsalva
7
25-Sep-00
МО book 2
11
12
13
14
15
Questionary
5-23E
Eyes-Lids
Normal
1
Redness
2
Swelling
3
Lesion
4
Itch
5
Crusting
6
Swelling around eyes
(Periorbital Edema)
7
Eyes- Conjunctiva
Normal
1
Redness
2
Hemorrhage
3
Tearing
4
Dryness
5
Chest
Normal
1
Asymmetric appearance
2
Asymmetric movement
3
Shallowing breathing
4
Deep breathing
5
Lungs
Normal
1
Coarse breath sounds
2
Decreased/Weak
Respiration
Crackles
3
Wheezing
5
Rales (fluid sounds)
6
4
Heart
Normal
1
Murmur
2
Irregular
3
25-Sep-00
МО book 2
16
17
Questionary
5-24E
Upper Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
Lower Extremities
Normal
1
Asymmetric Strength
2
Altered ROM
3
Tenderness
4
Swelling
5
Redness
6
Bruising
7
Lesions
8
2. BMM – The onboard instruction МО Book 2 Sec. 3.8 page 3-42
3. Urinalysis - The onboard instruction МО Book 2 Sec. 3.9 page 3-53
25-Sep-00
Download PDF