Installation Inst ru ct io n s
SERIN™
MODEL NUMBERS
2064.14X 2064.15X 206B.10X
Deck Mount Electronic
Proximity Lavatory Faucet
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Optional 206P400.XXX, 4" Deck Plate
Product No’.s & Options
1
Specifications
2
Faucet Installation
2-3
Electrical Installation
4-6
Start-up / Maintenance
7-8
FAQ’s / Troubleshooting
8-9
Replacement Parts
10
Optional 206P800.XXX, 8" Deck Plate
Certified to comply with ASME A112.18.1
© 2017 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@lixilamericas.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
© 2017 AS America Inc.
1
M965612 Rev. 1.8 (12/17)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
Remove the fitting and loose items from the carton. The illustration below shows all the fittings and loose items after they
have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Spout Assembly
3. Mounting Kit
4. Control Box
5. Supply Hose
6. 4" Deck plate (optional, must be ordered separately)
7. 8" Deck plate (optional, must be ordered separately)
8. Mixing Valve (optional, must be ordered separately)
9. Control Box Cover Screws
Spout
POWER KITS SOLD SEPARATELY
Plug-In AC
Power Kit
PK00.PAC
PRODUCT No.s
All 2064. SERIES
2
Hard-Wired AC
Power Kit
Multi-AC
Power Kit
PK00.HAC
PK00.MAC
1
B
P r o
I n s t a l l a t i o n I n s t ru c t i o n s
a s e
SERIN™
MODEL NUMBERS
Deck Mount Electronic
Proximity Lavatory Faucet
2064.14X
2064.15X
206B.10X
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS
supplied cables, or cutting, splicing or modifying
any components will void the warranty.
Optional 206P400.XXX, 4" Deck Plate
Product No.'s & Options
1
Specifications
2
Faucet Installation
2-3
Electrical Installation
4-6
Start-up / Maintenance
7-8
FAQ’s / Troubleshooting
8-9
Replacement Parts
10
Optional 206P800.XXX, 8" Deck Plate
Certified to comply with ASME A112.18.1
© 2014 American Standard
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
d
u
c t
4
9
5
3
Deck Plate
206P400.XXX
6
206P800.XXX
7
605XTMV1070
Mixing Valve
8
2
M965612 Rev. 1.8 (12/17)
Roughing-in Dimensions
GENERAL DESCRIPTION:
Electronic faucet with proximity operation. Vandal resistant solid brass construction
single post mounting. Operates on DC (battery/power pack) or AC permanent power
(plug-in/hardwire). In-line strainer for solenoid is integral. Single inlet 3/8 compression,
built-in check valves, and flexible stainless steel 16-1/4" reach inlet hose for spout
connection.
Note: All plumbing and electrical wiring must be installed in accordance
with applicable codes, regulations and standards.
(249mm)
9-3/4"
(136mm)
5-3/8"
(177mm)
7"
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
(173mm)
6-11/16"
MOUNTING
SURFACE
(100mm)
3-15/16"
32mm
(1-1/4") DIA.
125mm
(4-7/8")
114mm
(4-1/2")
RECOMENDED CONTROL BOX OR
EQUIVALENT BY OTHERS
4" (102mm) SQ. X 3-1/2" (89mm) DEEP CONTROL BOX
Hubbel-RACO #256 OR EQUAL (BY OTHERS).
413mm
(16-1/4")
81mm
(3-3/16")
500mm
(20")
HARD-WIRED AC ONLY 10' MAX. CABLE LENGTH
1524mm
(60")
3/8" COMP.
RECOMMENDED TOOLS
1. Slip Joint Pliers
2. Adjustable Wrench
3. Plumbers’ Putty or
Caulking
4. Phillips Screwdriver
5. Flat Blade Screwdriver
6. Electric Drill & 1/4"
Drill Bit
7. Tape Measure
1
2
3
7
4
6
10'
5
POUT ASSEMBLY
1 S
INSTALLATION; Fig. 1
CAUTION
Turn off hot and cold water
supplies before beginning
Fig. 1
1. Make sure O-RING (3) is installed into groove in
ESCUTCHEON RING (4).
2. Insert SENSOR CABLES (1), SPOUT HOSE (5) and
SPOUT SHANK (6) through center hole of mounting
surface. Fig. 1.
IMPORTANT: Do not
use putty when installing
faucet without escutcheon.
PUTTY
(If required) 6
3. Assemble RUBBER WASHER (7), BRASS WASHER (8)
and LOCKNUT (9) onto SHANK (6) from underside of
sink or mounting surface. Hand tighten LOCKNUT (9).
*12
4. Use a screwdriver to tighten SCREWS (10) on
LOCKNUT (9). Work your way around LOCKNUT (9),
tightening the screws slightly each time until all are
snugto ensure even pressure.
4
3
2
1
11
*(#12 CENTERING NUT) is
only used with the
installation of a 4" or 8"
deck plate
Note: 4" and 8” Deck Plates (11) are available for other
installations, see page one for information.
5
5. When using optional 4" or 8" DECK PLATE (11) first
thread the DECK PLATE CENTERING NUT (12) onto
SHANK (6). Thread the DECK PLATE CENTERING
NUT (12) tight against the underside of the faucet base.
7
8
SENSOR
CABLES
MOUNTING
SURFACE
10
9
6. Follow steps 1-4 above for the spout installation.
3
M965612 Rev. 1.8 (12/17)
2 MOUNT CONTROL BOX; Fig. 4
!
Fig. 4
LAVATORY RIM OR
MOUNTING SURFACE
Important: For AC installation, make sure power
supply connector is inserted into control box
through power supply grommet before control box
is mounted to the wall. Reference electrical
installation section (pages 5 & 6).
WASTE
NOTE: CONTROL BOX SUPPLY HOSE is 20". Distance
between wall supply and CONTROL BOX (3) must be
taken into consideration.
1524mm
(60")
20"
(500mm)
21"
(mm)
3"
(76mm)
3-3/4"
(96mm)
MOUNTING HOLES
2. Remove tape from CONTROL BOX COVER (1)
and pull off COVER (1). Hold the CONTROL BOX (3)
in desired location and mark the four mounting hole
locations as shown. Fig. 4.
NOTE: Find plastic bag containing 4 M5X16 screws to be
used for securing the CONTROL BOX COVER (1) when
installation is complete.
NOTE: For AC installation, make power supply
connection before mounting CONTROL BOX (3) to wall.
16
1
17
3
Fig. 5
3. It is recommended that the CONTROL BOX (3) be
securedto a wall stud or cross brace within the wall
using theSCREWS (16) supplied. If the CONTROL BOX
(3) is to beinstalled on tile or plaster walls, the
ANCHORS (17) andSCREWS (16) should be used.
18
3
C
ONNECT SPOUT HOSE TO
CONTROL BOX; Fig. 5
1. Connect SUPPLY NUT (18) from spout hose tonipple
on top of CONTROL BOX (3). Tighten withadjustable
wrench to make a water tight connection.Fig. 3.
4
2-3/4"
(71mm)
SUPPLIES
1. Determine location of CONTROL BOX (3). It must be
located with-in the 14" (356mm) by 21" (533mm)
shaded area shown in Figure 4 in order for electrical
connections from the spout assembly to be made.
3
ENCLOSURE
MOUNTING
HOLES
14"
(356mm)
Fig. 6
CONNECT WATER SUPPLY TO
3
CONTROL BOX AND WALL
SUPPLY; Fig. 6, 6a
18
19
3
NOTE; If using the optional Mixing Valve See Sheet
#M968808 for installation instructions.
Fig. 6a
1. Insert FIBER WASHER (19) into SUPPLY NUT (18) on
CONTROL BOX (3).
2. Connect FLEXIBLE SUPPLY HOSE (20) to SUPPLYNUT
(18) on CONTROL BOX (3). Tighten to make awater tight
connection. Use two wrenches to tightenif necessary. Fig. 6.
3. Connect FLEXIBLE SUPPLY HOSE (20) directly to wall
supply. Connection on FLEXIBLE SUPPLY HOSE (20) is
3/8" compression. Use adjustable wrench totighten
connection. Do not over tighten. Fig. 6a.
COLD WATER OR
TEMPERED
WALL SUPPLY
20
Note: FLEXIBLE SUPPLY HOSE (20) measures 20" from the
bottom of the CONTROL BOX (3) base. If additional supply
length is required, installer must purchase parts separately.
Important: If FLEXIBLE SUPPLY HOSE (20) is too long, loop
to avoid kinking.
4
M965612 Rev. 1.8 (12/17)
ELECTRICAL INSTALLATION
Product
Fig. 1
1
Page
Plug-In AC Power Kit (PK00.PAC)
6
Hard-Wired AC Power Kit (PK00.HAC)
6
Multi-AC Power Kit (PK00.MAC)
7
Fig. 1a
2
Fig. 1b
3
5a
5
A DC VERSIONS (PWRX & STANDARD
BATTERY); Fig. 1
INSTALL BATTERY
1. Remove CONTROL BOX COVER (1). Fig. 1.
4
2. Feed the SENSOR CABLES (2) through the top of
CONTROL BOX (3). Fig. 1a.
STANDARD
BATTERY
Fig. 1c
3. Insert BATTERY (4) into BATTERY HOLDER (5), make
sure the shape of the BATTERY (4) follows theshape
of the BATTERY HOLDER (5) and terminalend is
inserted first. Fig. 1b.
-P2
CR
6
5a
4. Insert the BATTERY CONNECTOR (5a) for theStandard
Battery or PWRX Battery Pack throughside GROMMET (6)
as shown. Fig. 1c.
5. Connect SOLENOID CABLE (7) and BATTERY
CONNECTOR (5a) to SENSOR CABLES (2). Place
Standard Battery or PWRX Battery Pack intoHousing.
Fig. 1d.
PWRX
5a
6. Replace CONTROL BOX COVER (1). Tighten cover
screws firmly.
Fig. 1d
STANDARD
BATTERY
7
2
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
PWRX
5a
5
M965612 Rev. 1.8 (12/17)
VERSION; Fig. 2
B AC
Fig. 2
• PLUG-IN
• HARDWARE
CAUTION
2
Disconnect AC power supply
before opening CONTOL BOX.
3
1
Note: For AC installation, make power supply connection
before mounting CONTROL BOX (3) to wall.
1. R
emove CONTROL BOX COVER (1). Feed the
EXTENSION CABLES (2) from the Faucet through
the top of ENCLOSURE (3).
FOR AC PLUG-IN ONLY
2a. Insert POWER CORD (8) through POWER SUPPLY
GROMMET (9). Fig. 2a.
3a. Insert POWER CORD (8) through side GROMMET (6)
as shown. Fig. 2a.
4a.Connect one of the 27" EXTENSION CABLES (2) to
SOLENOID CABLE (7) and the other to the SINGLE AC ADAPTER (10). Connect POWER CORD (8) to Single
AC Adapter (10) and install CONNECTOR LOCKING
DEVICE (16). Fig. 2a.
5a. Mount CONTROL BOX to wall. Replace CONTROL BOX
COVER (1). Tighten cover screws firmly.
6a. Plug AC POWER SUPPLY into wall outlet.
Fig. 2a
6
16
7
2
10
Fig. 2b
PLUG INTO
WALL OUTLET
9
8
2
FOR HARDWIRE HOOK-UP ONLY
2b. Insert one end of the 10' EXTENSION (10a) through
POWER SUPPLY GROMMET (9). Fig. 2b.
3b. Insert 10' EXTENSION (10a) through side
GROMMET (6) as shown. Fig. 2b.
4b. Connect 27" EXTENSION CABLES (2) to SOLENOID
CABLE (7) and the other to the 10' EXTENSION
CABLE (10a). Install CONNECTOR LOCKING DEVICE
(16). Fig. 2b.
Contractor to supply ELECTRICAL BOX (12) and power
to POWER SUPPLY (13).
5b. Mount POWER SUPPLY (13) onto ELECTRICAL
BOX (12). Connect connections to POWER SUPPLY
CONNECTIONS (14). Fig. 2c.
6b. Connect the10' EXTENSION (10b) to the POWER
SUPPLY CABLE (15). Fig. 2c.
2
16
6
7
9
10a
FROM ELECTRICAL BOX
WITH POWER SUPPLY
Fig. 2c
10b
10' EXTENSION
12
15
CAUTION: Use only American Standard supplied cable sets.
Using non-AS supplied cables, or cutting, splicing or modifying
any components will void the warranty.
14
BLACK & WHITE
POWER
CONNECTIONS
6
13
M965612 Rev. 1.8 (12/17)
Fig. 3
Unit #2
Unit #1
Unit #3
Already installed
10 ft.
EXTENSION
CABLE
AC POWER
SUPPLY
OR
BLACK &
WHITE
POWER
CONNECTIONS
*MAXIMUM OF 15 UNITS PER AC POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
OR AC-VERSION
C F
Unit #1 Detail
Fig. 3a
(MULTI HOOK-UP); Fig. 3, 3a, 3b
3
SENSOR
CABLES
1. Remove COVERS from all CONTROL BOX (2).
2. Remove SOLID BLACK PLUG GROMMET (5) from
leftside of all CONTROL BOX (2), except from Unit
#1.Replace with GRAY GROMMET (9). (Supplied with
each Faucet).
10b
2
2
3. Feed SENSOR CABLES (2) through the top of
CONTROL BOX (3). Connect one SENSOR CABLE (2)
to the SOLENOID CABLE (7), and the other to either
ofthe two terminals at the one end of the Y-ADAPTER
(11). Connect the 10’ EXTENSION (10a) to the other
terminal at the same end of the Y-ADAPTER (11).
2
5
11
4. Feed the other end of the 10 ft. EXTENSION (10b)
through the two GRAY GROMMETS (6a and 6b)
and connect to the single terminal end of the next
unit’s Y-ADAPTER (11). Place Y-ADAPTER (11) into
CONTROL BOX (3).
7
AC POWER SUPPLY
5. Repeat Steps above for each additional Unit, for a
Max. of 15 Units on one AC POWER SUPPLY (7).
6. Replace CONTROL BOX COVERS. Tighten cover screws firmly.
Fig. 3b
10a
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
6a
12
7
6b
10b
M965612 Rev. 1.8 (12/17)
START-UP / MAINTENANCE
Fig. 1
AND WASH SENSOR
A H
!
OPERATION; Fig. 4
rior to making power connection, make sure
P
detection zone is not obstructed. Sensor is self
adjusting. Keep detection zone clear for 15
seconds after power is connected.
ION
ECT
T
E
D
E:
ZON EN
E
W
BET T AND
U
O
NK
P
S
F SI
EO
S
A
B
When the Sensor detects a user, the water immediately
starts to flow. Water flow will stop 1.5 seconds after user is
out of sensor range. This comfort timer allows the user to
move his hands without the flow cycling on and off. As a
precaution, a safety timer will turn off the water after the
sensor has been blocked for 55 seconds. Water flow will
resume when the blockage is removed from the detection
zone and the sensor is activated again.
B HOW TO INSTALL AND CHANGE
Fig. 2
BATTERY; Fig. 2
1
1. Remove COVER from CONTROL BOX (1).
-P2
CR
2. Disconnect Battery Holder (3) from SENSOR CABLE (5).
2
3. Remove old BATTERY from Battery Holder (3). Install new BATTERY (2) making sure the terminal
side is inserted first and shape of the battery
follows the shape of the BATTERY HOLDER (3).
!
6
rior to making power connection, make sure
P
detection zone is not obstructed. Sensor is self
adjusting. Keep detection zone clear for 15
seconds after power is connected.
3
4
5
4. To change PWRX BATTERY PACK (4), unplug and
replace with new Power Pack.
5. Reconnect BATTERY HOLDER (3) to SENSOR CABLE (5).
Fig. 3
6. Replace CONTROL BOX COVER. Tighten cover screws
firmly.
7/16" SOCKET
C H
OW TO CLEAN FILTER
ASSEMBLY; Fig. 3
CAUTION
6
Before opening CONTROL BOX
disconnect AC power supply.
WHITE
DEBRIS
CUP
1. Remove CONTROL BOX COVER.
13
2. Close SUPPLY STOP (13) with 4mm Hex wrench.
Note: Activate sensor to keep water flowing out of faucet while shutting off.
•
• ••• •• • • • •
•••••••• • •• •• • • •• • • •
•••••••• • •• •• • • •• • • •• • • •• • •
•••••••• • •• • • • •• • • • • • • • • •
•••••••••••••• •• • •• •• •• • •••• •• •• • •• •
•
• • •••• • • • • •••• • • • • • •
••••••••••••• •• •• • •• •• • •••••••••• •• •
•••••• ••• ••
••• ••• •
••
•• •
• • •• • •••• •••• •• •
• • • • • • • •• •
• • • • • • • •• •
• • • • • • • •• •
• • • • • • • •• •
• •• •• •••
• ••
3. Unthread FILTER ASSEMBLY (6) using a 7/16" socket.
4. Pull out the FILTER ASSEMBLY (6), remove and clean white debris cup and filter screen.
FILTER
SCREEN
4mm HEX WRENCH
5. Install the FILTER ASSEMBLY (6) back in its place and tighten with a 7/16" socket.
Caution: Do not over tighten.
6. Open SUPPLY STOP (13) with 4mm Hex wrench.
7. Replace CONTROL BOX COVER. Tighten cover screws firmly.
8
M965612 Rev. 1.8 (12/17)
OW TO CLEAN AND REMOVE
D H
Fig. 4
THE AERATOR OR SPRAY; Fig. 4
9
1. Remove Aerator or Spray HOUSING (7) with KEY supplied with faucet.
8
2. Remove Aerator or Spray (8) from HOUSING (7).
7
7
3. Clean the Aerator or Spray SCREEN (9).
4. Reassemble and install into spout end. Be sure the black seal washer is in place.
KEY
E HOW TO CLEAN FLOW
REGULATOR; Fig. 5
Fig.5
3
1. Remove SUPPLY HOSE (1) from top of CONTROL
BOX ASSEMBLY (2). Pull out FLOW REGULATOR
(3) from CONTROL BOX ASSEMBLY (2).
1
2
2. Rinse clean FLOW REGULATOR (3). Reassemble
SUPPLY HOSE (1) to top of CONTROL BOX
ASSEMBLY (2).
3
RINSE CLEAN FLOW
REGULATOR (3)
F G
ENERAL CLEANING; Fig. 6
1. Only use a damp, soft cloth to clean the spout and
the sensor.
Fig.6
2. For tougher dirt, use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
CAUTION
Do not scratch the sensor when cleaning.
Avoid using any abrasives or harsh detergents or chemicals.
FAQ’S
Q: How will I know if the battery needs to be replaced?
A: Valve will not open and sensor will continuously blink 2 times interrupted by a pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced significantly?
A: The filter assembly, flow regulator or areator/spray may be clogged. Check and clean.
Refer to Start-up/Maintenance, s ections C, D and E.
Q: Why doesn’t the water flow out of faucet when I’m within the sensor detection zone?
A: Battery may need replacement. Check. If sensor continuously blinks 2 times interrupted by pause,
replace battery o
r call (855) 752-9259.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging from 20-80 psi.
9
M965612 Rev. 1.8 (12/17)
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
ARE EXTERNAL SUPPLY
STOPS OPEN?
NO
OPEN EXTERNAL SUPPLY STOPS.
NO
OPEN INTERNAL SUPPLY STOP.
(HEX KEY NEEDED)
YES
CRITICALLY LOW BATTERY.
INSTALL NEW BATTERY.
YES
IS INTERNAL SUPPLY
STOP OPEN?
YES
REPEATED DOUBLE FLASH
ON SENSOR?
NO
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
1
2
NO
NO
YES
1
2
DEAD BATTERY. INSTALL
NEW BATTERY. REPEAT.
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
REPLACE SOLENOID
WATER IS CONTINUOUSLY RUNNING
RECONNECT BATTERY TO SENSOR.
DOES SENSOR FLASH FOR 5 SECONDS?
NO
CHECK FOR DAMAGE TO SENSOR WIRE INSULATION.
REPLACE SENSOR.
NO
FULLY OPEN INTERNAL & EXTERNAL SUPPLY
STOPS BY TURNING COUNTER CLOCKWISE.
YES
REPLACE SOLENOID
LOW FLOW ISSUES
ARE INTERNAL & EXTERNAL SUPPLY
STOPS FULLY OPEN?
YES
LOW FLOW COULD BE CAUSED BY DEBRIS
IN THE FILTER ASSEMBLY, FLOW REGULATOR
OR AERATOR/SPRAY. REMOVE, CLEAN AND
INSERT BACK TO ORIGINAL POSITION.
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
P ro d u c t n a m e s l is t e d h erei n are t rad em ark s of A S A m eri ca, I n c . ©2 0 1 7
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@lixilamericas.com
10
M965612 Rev. 1.8 (12/17)
Download PDF