S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S/I/T/C of IT and Network Integration for
National Institute of Design (NID) at Kurukshetra,
Haryana for Department of Industrial Policy &
Promotion (DIPP)
TECHNICAL SPECIFICATIONS
&
LIST OF APPROVED MAKES
(Vol-II)
OFFICE OF THE RBG (DELHI-I)
NBCC Business Centre, Logix Technova, 8th Floor, Sector-132, Noida
E-MAIL- sbg.delhi1@nbccindia.com
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 1 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
TECHNICAL SPECIFICATIONS
1
INSTRUCTION & SPECIAL CONDITIONS FOR SUBMISSION OF TENDER
1.1
INTRODUCTION: It is proposed to Supply, Installation, Testing and Commissioning of IT
and Network Integration work as per Schedule of Quantities given in the tender. The IT and
Network Integration work shall comprise of following :a) SITC of UPS
b) SITC of CCTV System
c) SITC of I.T. System
d) SITC of EPABX System
1.2
GENERAL:
A) This specification covers manufacturer, testing as may be necessary before dispatch,
delivery at site, all preparatory work, assembly and installation, final testing, commissioning,
putting into operation including one year guarantee period for the following Work.
B) Name of Work : IT and Network Integration work
C) The work shall be executed as per latest IS/IEC Specifications as amended up to date,
relevant IEC rules and as per directions of Engineer-in-Charge. These additional
specifications & conditions are to be read in conjunction with above and in case of variations;
specifications given in the Additional Specifications & Conditions shall apply. However,
nothing extra shall be paid on account of these as the same are to be read along with
schedule of quantities for the work.
1.3
SHOP DRAWING:
On the award of the work, the Contractor shall immediately proceed with the preparation of
detailed working drawings showing the detail of each equipment that are to be installed and the
associated works that are to be carried out. All the works are deemed to be included in various
items of bill of quantities as applicable.
Three sets of all such working drawings dully signed by the head of the planning & design
department of the tenderer shall be submitted to the consultants / Engineer-in-charge for approval
to ensure that the works will be carried out in accordance with the specifications and drawings,
including such changes as may have been mutually agreed upon. All the drawings shall be
received by the Consultants/ Engineer-in-charge for approval within 04 (Four) weeks from the
date of award of work. The approval of the drawings by the Consultants / Engineer-in-charge
shall in no way relieve the Contractor form his obligations to provide a complete and satisfactory
plant installation, testing and commissioning as per intent and purpose as laid down in the
specifications.
Any omissions and / or errors shall be made good or rectified whether or not the drawings are
approved. Contractor shall obtain written approval for samples as cable tray, cable tag, and other
materials before placing the order.
The Contractor shall also fix operation schedule chart, in the Operating / Maintenance Room,
neatly typed and framed, instructions in details, for the starting and running of the electrical
equipment.
The shop drawings shall be prepared by the electrical contractor based on GFC Drawing
approval of Architect / Consultant/ Engineer-In-Charge.
The all equipment manufacturing drawings shall be prepared by the electrical contractor /
manufacturer for approval of Architect / Consultant/ Engineer-In-Charge.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 2 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
1.4
AS BUILT DRAWING:
At the completion of work and before issuance of certificate of virtual completion the contractor
shall submit Four (04) sets to the Engineer-in-charge, layout drawing drawn at appropriate scale
indicating the complete IT and Network Integration system “as installed”.
1.5
INSTRUCTION/MAINTENANCE MANUAL:
The Contractor shall prepare and produce instruction, operation and maintenance manuals in
English for use, operation and the maintenance of the supplied equipment and installations, and
submit to the Engineer-in-charge in three copies at the time of handing over. The manual shall
generally consist of the following:
a) Description of the Project.
b) Operating instructions.
c) Maintenance instructions including procedures for preventive maintenance.
d) Manufacturers catalogues.
e) Spare parts list.
f)
Trouble shooting charts.
g) Drawings.
h) Type and routine test certificates of major items.
i)
Three (3) set of reproducible ‘as built’ drawings.
2
TECHNICAL SPECIFICATION OF EQUIPMENTS
2.1
SUB HEAD – I – UPS SYSTEM
BOQ Item No- NS-1 UPS 20 KVA
Input Voltage
Voltage range
Frequency
INVERTER
Output Wave Form
Output voltage
Output voltage regulation
Output Frequency
Output Isolation
Power Factor
THD
Technology
Overload Capacity
Crest Factor
Transient Recovery
BATTERY CHARGER
Charger Type
Charging Mode
OPERATING CONDITIONS
Operating Temperature
Humidity
Noise Level
RESPONSE TIME
Transfer Time
Three Phase
340 to 460V
45-55 Hz
Pure Sine Wave
415V/400V/380V (adjustable)
+/- 1%
50Hz +/- 0.01%
Galvanic Isolation
0.8 to unity
Less than 3%
Micro controller based Hi Freq. PWM
110% for 10 Min.
4:1
Within 3 cycle
Constant Voltage Constant Current
Trickle, Float & Boost
0-45 °C
90% Non Condensing
Less than 45dB
0 ms
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 3 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-2 UPS 15 KVA
Input Voltage
Voltage range
Frequency
INVERTER
Output Wave Form
Output voltage
Output voltage regulation
Output Frequency
Output Isolation
Power Factor
THD
Technology
Overload Capacity
Crest Factor
Transient Recovery
BATTERY CHARGER
Charger Type
Charging Mode
OPERATING CONDITIONS
Operating Temperature
Humidity
Noise Level
RESPONSE TIME
Transfer Time
Three Phase
340 to 460V
45-55 Hz
Pure Sine Wave
415V/400V/380V (adjustable)
+/- 1%
50Hz +/- 0.01%
Galvanic Isolation
0.8 to unity
Less than 3%
Micro controller based Hi Freq. PWM
110% for 10 Min.
4:1
Within 3 cycle
Constant Voltage Constant Current
Trickle, Float & Boost
0-45 °C
90% Non Condensing
Less than 45dB
0 ms
BOQ Item No- NS-3 UPS 5 KVA
Specifications
Input Voltage
Output Wave Form
Voltage range
Frequency
Single Phase
Pure Sine Wave
170 to 270 V
45-55 Hz
INVERTER
Output voltage
220 V
Output voltage regulation
+/- 1%
Output Frequency
Power Factor
THD
Technology
Overload Capacity
Crest Factor
Transient Recovery
OPERATING TEMPRATURE
HUMIDITY
NOISE LEVEL
50Hz +/- 0.01 Hz
0.9 to unity
Less than 3%
Micro Controller based High Frequency PWM
Technology
Using Isolation Transformer
110%
4:1
Within 3 cycle
0-45º C
90% Non Condensing
Less than 45dB
TRANSFER TIME
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 4 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
Line to Battery mode
0 ms
Battery to Line mode
0 ms
Line to Bypass mode
< 5 ms synchronized with mains
Bypass to Line mode
LCD DISPLAY
OPTIONAL FEATURES
< 5 ms synchronized with mains
On main
Battery voltage
On Battery
Overload
Battery low
External Battery Bank for longer back-up
Static bypass
BOQ Item No- NS-4 UPS 7.5 KVA
Specifications
Input Voltage
Single Phase
Output Wave Form
Pure Sine Wave
Voltage range
170 to 270 V
Frequency
45-55 Hz
INVERTER
Output voltage
220 V
Output voltage regulation
+/- 1%
Output Frequency
50Hz +/- 0.01 Hz
Power Factor
0.9 to unity
THD
Technology
Overload Capacity
Less than 3%
Micro Controller based High Frequency PWM
Technology
Using Isolation Transformer
110%
Crest Factor
4:1
Transient Recovery
Within 3 cycle
OPERATING TEMPRATURE
0-45º C
HUMIDITY
90% Non Condensing
NOISE LEVEL
Less than 45dB
TRANSFER TIME
Line to Battery mode
0 ms
Battery to Line mode
0 ms
Line to Bypass mode
< 5 ms synchronized with mains
Bypass to Line mode
< 5 ms synchronized with mains
LCD DISPLAY
On main
On Battery
Battery low
Battery voltage
Overload
OPTIONAL FEATURES
External Battery Bank for longer back-up
Static bypass
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 5 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-5 UPS 2.5 KVA
Specifications
Input Voltage
Output Wave Form
Voltage range
Frequency
Single Phase
Pure Sine Wave
170 to 270 V
45-55 Hz
INVERTER
Output voltage
220 V
Output voltage regulation
+/- 1%
Output Frequency
Power Factor
THD
Technology
Overload Capacity
Crest Factor
Transient Recovery
OPERATING TEMPRATURE
HUMIDITY
NOISE LEVEL
50Hz +/- 0.01 Hz
0.9 to unity
Less than 3%
Micro Controller based High Frequency PWM
Technology
Using Isolation Transformer
110%
4:1
Within 3 cycle
0-45º C
90% Non Condensing
Less than 45dB
TRANSFER TIME
Line to Battery mode
0 ms
Battery to Line mode
0 ms
Line to Bypass mode
< 5 ms synchronized with mains
Bypass to Line mode
< 5 ms synchronized with mains
LCD DISPLAY
OPTIONAL FEATURES
On main
Battery voltage
On Battery
Overload
Battery low
External Battery Bank for longer back-up
Static bypass
BOQ Item No- NS-6 UPS 30 KVA
Input Voltage
Three Phase
Voltage range
340 to 460V
Frequency
45-55 Hz
INVERTER
Output Wave Form
Output voltage
Output voltage regulation
Output Frequency
Output Isolation
Power Factor
THD
Pure Sine Wave
415V/400V/380V (adjustable)
+/- 1%
50Hz +/- 0.01%
Galvanic Isolation
0.8 to unity
Less than 3%
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 6 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
Technology
Overload Capacity
Crest Factor
Transient Recovery
Micro controller based Hi Freq. PWM
110% for 10 Min.
4:1
Within 3 cycle
BATTERY CHARGER
Charger Type
Charging Mode
Constant Voltage Constant Current
Trickle, Float & Boost
OPERATING CONDITIONS
Operating Temperature
Humidity
Noise Level
0-45 °C
90% Non Condensing
Less than 45dB
RESPONSE TIME
Transfer Time
0 ms
BOQ Item No- NS-7 UPS 40 KVA
Input Voltage
Voltage range
Frequency
INVERTER
Output Wave Form
Output voltage
Output voltage regulation
Output Frequency
Output Isolation
Power Factor
THD
Technology
Overload Capacity
Crest Factor
Transient Recovery
Three Phase
340 to 460V
45-55 Hz
Pure Sine Wave
415V/400V/380V (adjustable)
+/- 1%
50Hz +/- 0.01%
Galvanic Isolation
0.8 to unity
Less than 3%
Micro controller based Hi Freq. PWM
110% for 10 Min.
4:1
Within 3 cycle
BATTERY CHARGER
Charger Type
Charging Mode
Constant Voltage Constant Current
Trickle, Float & Boost
OPERATING CONDITIONS
Operating Temperature
Humidity
Noise Level
0-45 °C
90% Non Condensing
Less than 45dB
RESPONSE TIME
Transfer Time
0 ms
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 7 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
2.2
S.H.-II CCTV
BOQ Item No- NS-8 HD Analog Camera
Sr. No.
Description
Specification
1
Image Sensor
2.0 Megapixel, 1/4"or 1/3" CMOS or better
2
Housing
Metal
3
Effective Pixels
1920 (H} x 1080 (V}
4
Electronic Shutter
1/25 - 1/10,000 Sec
5
Video Frame Rate
1080P @ 25fps (PAL}
6
1080P @ 30fps(NTSC}
7
Lens
2.8-12mm varifocal
8
Min. Illumination
0.1Lux @(F1.2,AGC ON} ,0.05 Lux with IR
9
Video Output
1 channel BNC
10
Day/Night
IR cut
11
IR Type
24 IR LEDs or better
12
IR Range
25m or higher
13
Power Supply
DC12V±10%
14
Working Environment
-10°C~+55°C/ Less than 95%RH
15
Ingress Protection
IP66
16
Certifications
UL Listed, CE, FCC
BOQ Item No- NS-9 16 Chanel DVR
Sr. No.
Description
Specification
1
Video Compression
H.264
2
Video System
NTSC/PAL
3
Operation System
Linux(embedded}/Windows
4
Processor
ARM based Dual Processor
5
Analog video-input/output
16CH inputs / VGA and HDMI output
6
Composite Video Input
Up to 24CH (Analog video }
7
Audio input /output
16CH inputs /1CH output(RCA}
8
Display Resolution
Analog :1080P/720P/960H
9
Record Resolution
Analog :1080P/720P/960H
Analog
:1080P
:30fps(each
ch}
720P:30ps(each ch} 960H:30fps(each ch}
128Mbps
10
Record Speed
11
Maximum output Bandwidth
13
Maximum
performance
Recording Mode
14
Synchronous Playback
16CH
15
Network Type
16
HDD interface
17
Multiplex Operation
LAN, DHCP, and DDNS
2 SATA HDDs, 2 x Surveillance Grade 4TB
SATA HDD pre- installed
live display, record, playback, backup and
network
18
USB
2 x USB (for mouse and backup/upgrade}
19
Sensor & Alarm I/O
16 inputs / 1 output
12
Compliance
decode
Compliance
1080P:16CH realtime
Continuous/Manual/Motion detect
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 8 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
20
PTZ Control
21
Mobile Surveillance
22
VGA/HDMI
23
Power Supply
yes (RS485}
Support Mobile Phones based on iPhone
and Android operation system
1024*768,1280*1024, 1440*900, 1280*720,
1920*1080
1680*1050,1600*1200,
1920*1200, 2560*1440 ,3840*2160
DC 12V/5A
24
Certifications
UL Listed, CE, FCC
25
Working Temperature
-10°C~+55°C
26
Working Humidity
10%~90%
BOQ Item No- NS-10 08 Chanel DVR
1
Video Compression
H.264
2
Video System
NTSC/PAL
3
Operation System
Linux(embedded}/Windows
4
Processor
ARM based Dual Processor
5
Analog video-input/output
8 CH inputs / VGA and HDMI output
6
Composite Video Input
Up to 12 CH (Analog video }
7
Audio input /output
4CH inputs /1CH output(RCA}
8
Display Resolution
Analog :1080P/720P/960H
9
Record Resolution
Analog :1080P/720P/960H
10
Record Speed
11
13
Maximum output Bandwidth
Maximum
decode
performance
Recording Mode
14
Synchronous Playback
8 CH
15
Network Type
16
HDD interface
17
Multiplex Operation
18
USB
LAN, DHCP, and DDNS
1 SATA HDDs, 1 x Surveillance Grade 4TB
SATA HDD pre- installed
live display, record, playback, backup and
network
2 x USB (for mouse and backup/upgrade}
19
Sensor & Alarm I/O
16 inputs / 1 output
20
PTZ Control
21
Mobile Surveillance
22
VGA/HDMI
yes (RS485}
Support Mobile Phones based on iPhone
and Android operation system
1024*768,1280*1024,1440*900,1920*1080
23
Power Supply
DC 12V/2A
24
Certifications
UL Listed, CE, FCC
25
Working Temperature
-10°C~+55°C
26
Working Humidity
10%~90%
12
Analog
:1080P
:30fps(each
ch}
720P:30ps(each ch} 960H:30fps(each ch}
32 Mbps
1080P:8 CH realtime
Continuous/Manual/Motion detect
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 9 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No-NS-11 40’’ Full HD Display
Sr. No
Feature
Required Parameters
Compliance
Diagonal Size 40"
Type 60Hz LED BLU
Resolution1920x1080 (16:9)
Pixel Pitch(mm) 0.15375(H) x 0.46125(V)
i.
Panel
Brightness(Typ.) 350nit
Contrast Ratio 5000:1
Viewing Angle(H/V) 178:178
Response Time(G-to-G) 8ms
Display Colors 16.7M
Color Gamut 72%
Dynamic C/R 100,000 : 1(AV Mode)
ii.
Display
H-Scanning Frequency 30 ~ 81kHZ
V-Scanning Frequency 48 ~ 75HZ
Maximum Pixel Frequency 148.5MHz
RGB Analog D-SUB, DVI-D
VIDEO Component, CVBS, HDMI
iii.
Connectivity Input/output
iv.
Power
v.
Embedded H/W)
AUDIO Stereo mini Jack
EXTERNAL CONTROL RS232C(in/out),
RJ45
Power Supply AC 100 - 240 V~ (+/- 10 %),
50/60 Hz
Power Consumption Max[W/h] 119
Power Consumption Typical[W/h] 87
Power Consumption BTU(Max) 405,79
Power Consumption Sleep mode less than
1W
Power Consumption Off mode less than 1W
Processor Cortex-A8 Single Core CPU with
NEON DSP
On-Chip Cache Memory L1 (I/D) : 32KB /
32KB L2 (Unified) : 512KB
Clock Speed Up to 800MHz
Main Memory Interface Dual 32bit DDR3-667
(1333MHz)
Graphics 2D & 3D Graphics Engine Up to
1920x1080. 32bpp, Supports OpenGL ES
Storage (FDM) 4GB (1.2GB Occupied by
O/S, 2.8GB)
Multimedia Video Decoder MPEG-1/2,
H.264/AVC (Dual), VC-1, JPEG, PNG Audio
DSP (Decoder)- AC3 (DD), MPEG, DTS
Host Bus PCIEx 2.0
.
IO Ports PCIEx 2.0
Operating System Linux
vi.
Operation
Operating Temperature 0℃~ 40℃
Humidity 10~80%
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 10 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-12- Power Supply
S.No
Power Supply
2 AMP 12 Volt DC
BOQ Item No- NS-13- BNC Connector
S.No
BNC Coonector
RG6 Bnc connectors
BOQ Item No -NS-14- PTZ Camera with IR 100 Mtr
S.No
Features
Specifications
1
Certifications
UL ,CE,FCC
2
Compatibility
ONVIF profile s
3
Sensor
1/3 " Progressive CMOS or larger
4
Resolution
3 MP ( 2048 X 1536 )
5
Multiple Stream
6
Frame Rate
Minimum Triple Stream
upto 25 fps @ 3MP, Upto 50fps @ 2MP
( Main Stream)
7
Focal Length
4.3-129 mm
8
Field Of view
60° - 2.4 °
9
Optical Zoom
30X
10
Digital Zoom
10X
11
Focus
Auto / Manual
12
WDR
120 dB
13
Noise Reduction
2D / 3D
14
Shutter Speed
1/3 ~ 1/10000 sec.
15
IR
Inbuilt IR , IR distance upto 100 mtr
16
Day & Night
IR Cut filter
17
Min Illumination
0.05 @ F1.6 (Color), B/W : 0.005 Lux @ F1.6
18
Iris
Auto iris
19
SD Card support
Yes
20
Video Compression
H.264 , MJPEG
21
Privacy Mask
upto 20 privacy zones
22
Audio
1/1 channel In/Out
23
PAN
360 ° endless , Manual speed 0.1° ~ 90°/s ,
preset speed upto 280°/s
24
Tilt
,-15 ° ~ 90° , Manual speed 0.1° ~ 60°/s , Preset
speed upto 300°/s , Auto flip
25
26
Presets
Protocols
256
IPv4/v6, TCP/IP, UDP, RTP, RTSP, HTTP,
HTTPS,ICMP, FTP, SMTP, DHCP, PPPoE,
UPnP, IGMP, SNMP, QoS,ONVIF
27
Alarm
2 Input / 1 Output
28
BNC
1 X BNC
29
Ethernet Interface
1 X RJ 45
30
31
Weather Proof
Operating Temperature
IP 66
,-30°C ~ 50°C
32
Power Supply
24 V AC / POE
Compliance
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 11 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-15- 9U Rack
SN
Feature
i.
Size
2.3
1
2
3
4
5
ii.
Type
Required Parameters
9U, 19", 600 x 600 mm with Cam Lock & PU
Gasket
Single steel sheet construction, wall Mount
iii.
iv.
Doors
Cooling
Front side tinted glass
230 VAC fan on ceiling
v.
vi.
Locking system
Power Strip
vii.
I Accessories
Front door lock & key
19" mountable with min 6 no's sockets of 5
Amp
I All necessary accessories for mounting
Compliance
S.H.-III – I.T. SYSTEM
TECHNICAL SPECIFICATION FOR PASSIVE
COMPONENTS
General Passive Specifications
All Copper & Fiber components should be from the same
OEM.OEM should submit ISO certificate for the
manufacturing facilities related to all products involved in
tender.
All Passive Components should be RoHS (Restriction of
Certain Hazardous Substances) compliant. Declaration
for RoHS Compliance
All Copper and Fiber Components produced under
Environmental protection, based on the EN ISO140001
standard
There should be 20 year extended performance
warranty/Application Assurance for end -to-end channel.
All the components should comply with their respective
specifications stated below.
BOQ Item No- NS-19 Cat 6 Information outlet
1
INFORMATION OUTLET
Category 6, EIA/TIA 568-C.2
information outlets Should accept cables from 22-24 AWG
copper
Should be PCB free and Tool less will be added advantage
Material :Halogen Free
Should be Certified by independent labs like
ETL/GHMT/3P for compliance
BOQ Item No- NS-20 & 21 - Cat6 3 Feet & 7 feet Patch cord
MOUNTING CORDS CAT 6 (1 meter and 2 meter)
Should be Compliant with Cat.6 requirements of
ISO/IEC 11801, EN 50173, EN 50168 and
EIA/TIA 568.C.2
The Outer Jacket should be Low Smoke Zero
Halogen
Should be stranded bare copper
Should be unshielded
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 12 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-22 Loaded Patch Panel 24 Port.
24 PORT JACK PANEL UNLOADED
Should Be made of sheet steel 1.5 mm
Should be 19" 1U straight Patch Panel, 24-port
Should have integral cable management Metal
shelf.
Should accept Shielded as well as Unshielded
jacks
Should have rear cable management shelf
metallic powder coated
BOQ Item No- NS-23 Face Plate.
FACE PLATE
Square plate, 86mmx86mm
Write on labels in transparent plastic window –
supplied with plate
Material :ABS Plastic
BOQ Item No- NS-24 Face Plate.
SN
i.
Feature
Size
ii.
Type
Required Parameters
42U, 19", 800 x 1000 mm with Cam Lock & PU
Gasket
Single steel sheet construction, wall Mount
iii.
iv.
Doors
Cooling
Front side tinted glass
230 VAC fan on ceiling
v.
vi.
vii.
Locking system
Power Strip
I Accessories
Front door lock & key
19" mountable with min 6 no's sockets of 5 Amp
I All necessary accessories for mounting
Compliance
BOQ Item No- NS-25 Open Rack 45U
a. The data equipment rack shall be constructed of extruded aluminum or steel and capable of
accepting 19" wide EIA equipment.
b. The telecommunications rack shall be constructed of extruded aluminum and capable of accepting
23" wide telecommunications equipment.
c.
Rack construction method shall ensure an electrically bonded structure for ease of grounding.
d. The 3" channel rack shall be UL listed for 1000 lbs. load rating and the 6" channel rack shall be UL
listed for 1500 lbs. load rating.
e. The equipment mounting rails shall be double-sided #12-24 EIA universal mounting hole spacing.
f.
The equipment mounting rails shall include printed rack space identification on the front and back and
be numbered up.
g. The channel of the rack shall be capable of mounting
h. #12-24 threaded equipment mounting rails 84.0"H x 20.3"W x 3"D (2134mm x 514mm x 76mm), 45
RU
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 13 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
i.
Packaging: Includes right and left mounting rack channels, top and bottom brackets, assembly
hardware with paint piercing washers and anti-oxidizing paste for complete rack bonding.
j.
Extruded aluminum construction : Designed to be lightweight and durable for easier deployment and
reduced transportation costs; UL listed for 1000 lbs.
k.
Printed rack space identification : Allows for quick location of rack mounted equipment for faster
installation and less rework; see individual customer drawings for specific rack RU numbering
l.
Paint piercing washers : Fully electrically bonds rack components to simplify grounding process for
improved network reliability
m. Double-sided #12-24 mounting holes : Provides ability to mount equipment on both sides of the rack
channel for improved system flexibilit
BOQ Item No NS-26- 15U Rack
SN
Feature
i.
Size
ii.
Type
iii.
iv.
Doors
Cooling
v.
vi.
Locking system
Power Strip
vii.
I Accessories
Required Parameters
15U, 19", 600 x 600 mm with
Cam Lock & PU Gasket
Single steel sheet construction,
wall Mount
Front side tinted glass
230 VAC fan on ceiling
Compliance
Front door lock & key
19" mountable with min 6 no's
sockets of 5 Amp
I All necessary accessories for
mounting
BOQ Item No- NS-27 - 6 Core Fiber cable SM
Should be ISO/IEC 11801:2002; IEC 60794-1-2 E1; IEC
60794-1-2 E11; IEC 60794-1-2 E3;IEC 60794-1-2 F1; IEC
60332-1; IEC 61034; IEC 60754-2
Should Contain Glass yarn reinforced
Type :Single Mode OS2
Cable Jacket material : Low Smoke Zero Halogen
Minimum Cores 6
BOQ Item No NS-28 to NS-30 Fiber Items
S.No
Specifications – 12 and 24 ,48 Port LIU with fully
loaded adapters and connectors and other accessories
1
Fiber Optic LC style ,19" Rack Mount with 12/24/48
nos. of OS2 9/125μ Pigtails Shall have 12/24 nos. of
ISO/IEC-11801-OS2 fiber with accessories Shall have
all necessary accessories for fiber management inside
such as Fiber guides, radius controls & secure tie
downs within the FOPP
Complied
(Yes/No)
Compliance
Reference
Page No.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 14 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No NS-33 Fiber Patch Cord Items
S.No
Specifications - Optical Fiber Patch Cords MM 3 Meters
1
Fiber Optic Patch Cable (LC-LC), 3 Mtrs. Long, ISO/IEC11801-OM3
50μ
Duplex,
LSZH
All patch cords shall conform to EIA/TIA-568C.3 and
ISO/IEC-11801 Shall be RoHS Compliant.
BOQ Item No- NS-36
Complied
(Yes/No)
Compliance
Reference
Page No.
24Port Manageable Network Switch
SL
Specification
Non Blocking architecture
1
Architecture
Switch should support stacking up to 8 switches or more
with stacking bandwidth of 40Gb/s per switch.
Compliance Yes/No
Should support internal/ external redundant PSU
The switch should have 24 x 10/100/1000Base t ports with
8x 1000x SFP ports .
The switch should be upgraded to 4 x SFP+ ports in
future without changing the base hardware . Should have
min 2x Stacking port with min 40 Gbps stacking bandwidth
from day 1 .Stacking should be ready from day 1 with
accessorries /cables.Stacking mechanism could be
achieved over a diversified location as minimum 800
Meters .
Switch should have dedicated 1 x 10/100/1000 BaseT port
for Out of band Management port.
2
Performance &
Scalability
Switch should have switching fabric performance of
minimum 128Gbps switch fabric.
Switch should have forwarding rate of 92 Mpps
Switch should have 16K MAC entries table.Should have 8
Hardware QOS Queues per port ,OS should support
individual process (eg ssh , snmp, telnet, dhcp etc) restart
to prevent reboot in case of Software Process Crash by
running processes on top of Kernel.
3
Layer 2, IP v4
& IP v6
Switch should have IEEE 802.1Q VLANs and trunks.
Switch should have IEEE 802.1ak MVR,Vlan Trunking
Protocol (VTP) OR equivalent for dynamic vlan creation
Switch should have IEEE 802.1AB Link Layer Discovery
Protocol LLDP
Switch should have Routing Information Protocol Version
2 (RIPv2) and RIPng from day 1 , Scalable to OSPF
Switch should have Policy-based routing (PBR) for IPv4
and IPv6.Should have traffic rate limiting with Configurable
bandwidth granularity of 8 KBps
Switch should be upgradeable to Open Shortest Path First
(OSPF) and VRRP. Should support less than 50
Millisecond convergance for ring based architecture based
on RFC 3619/REP/ERPS/G.8032 etc
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 15 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
4
Network-based
availability
&
Security
Features:
Switch should have Port, vlan, IPv4, IPv6, and time based
Access Control Lists for both directions
Switch should support creation of minimum 1000 number
of Access Control Lists on each Port, vlan, IPv4 & IPv6.
Switch should have Ethernet OAM : IEEE 802.1ag Layer 2
Ping & traceroute, Multicast traceroute, Should support
AVB to ensure set of standards that provide the means for
highly reliable delivery of low- latency, time-synchronized
AV streaming services through Layer 2 Ethernet
networks, Should have SSH-2, SCP, SFTP for secure
management ,Should have MAC security – Lockdown &
Limit and MAC address tracking with syslog & snmp
notification, Multicast traceroute.
Should have scheduled archiving / uploading
configuration and system log to a central server
of
5
Energy
Efficiency
Switch should have have variable fan speed control for the
energy efficiency .
6
Automation,
Serviceability
and
Manageability
Switch should have Simple Network Management Protocol
(SNMP): complying with SNMPv1, v2c, and v3 with
comprehensive collection of MIBs., The switch should
have mechanism for variable fan speed, Should be SDN
capable with Openstack support and OpenFlow API
support, Should support IEEE P802.1Qaz
Should support Embedded event manager or
equivalent scripting system that can detect network
events and automatically take action, such as executing
commands or sending an Syslog event / Snmp trap.
Switch should be SDN capable with Open flow support
Switch should support IEEE 802.3az energy saving.
7
Environmental
Condition
Switch should have Operating temperature: 32 to
122°F (0°C to 50°C).
Switch should have Operational relative humidity: 10 to
90%, non- condensing.
8
Standard
&
Certification
Switch should have ETSI EN 300 ,WEEE,CSA 22.2,FCC
9
OEM Criteria
All the switches , Wireless controller , Access Points and
the fiber modules should be from the same OEM . The
OEM should have R&D center in India . The OEM should
have atleast 2 RMA depot in India and should have India
Toll free number with India TAC center - reflected on the
official website
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 16 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-37 48 port Manageable Network Switch
SL
Specification
Non Blocking architecture
1
Architecture
Switch should support stacking up to 8 switches or
more with stacking bandwidth of 40Gb/s per switch.
Compliance Yes/No
Should support internal/ external redundant PSU
The switch should have 48 x 10/100/1000Base t ports
with 8x 1000x SFP ports .
The switch should be upgraded to 4 x SFP+ ports in
future without changing the base hardware . Should
have min 2x Stacking port with min 40 Gbps stacking
bandwidth from day 1 .Stacking should be ready from
day 1 with accessories /cables. Stacking mechanism
could be achieved over a diversified location as
minimum 800 Meters .
Switch should have dedicated 1 x 10/100/1000 BaseT
port for Out of band Management port.
2
Performance
Scalability
&
Switch should have switching fabric performance of
minimum 176Gbps switch fabric.
Switch should have forwarding rate of 130 Mpps
Switch should have 16K MAC entries table.Should
have 8 Hardware QOS Queues per port ,OS should
support individual process (eg ssh , snmp, telnet,
dhcp etc) restart to prevent reboot in case of Software
Process Crash by running processes on top of Kernel.
3
Layer 2, IP v4 & IP
v6
Switch should have IEEE 802.1Q VLANs and trunks.
Switch should have IEEE 802.1ak MVR,Vlan Trunking
Protocol (VTP) OR equivalent for dynamic vlan
creation
Switch should have IEEE 802.1AB Link Layer
Discovery Protocol LLDP
Switch should have Routing Information Protocol
Version 2 (RIPv2) and RIPng from day 1 , Scalable to
OSPF
Switch should have Policy-based routing (PBR) for
IPv4 and IPv6.Should have traffic rate limiting with
Configurable bandwidth granularity of 8 KBps
Switch should be upgradeable to Open Shortest Path
First (OSPF) and VRRP. Should support less than 50
Millisecond convergance for ring based architecture
based on RFC 3619/REP/ERPS/G.8032 etc
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 17 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
4
Network-based
availability
&
Security Features:
Switch should have Port, vlan, IPv4, IPv6, and time
based Access Control Lists for both directions
Switch should support creation of minimum 1000
number of Access Control Lists on each Port, vlan,
IPv4 & IPv6.
Switch should have Ethernet OAM : IEEE 802.1ag
Layer 2 Ping & traceroute, Multicast traceroute,
Should support AVB to ensure set of standards that
provide the means for highly reliable delivery of lowlatency, time-synchronized AV streaming services
through Layer 2 Ethernet networks,Should have
SSH-2, SCP, SFTP for secure management ,Should
have MAC security – Lockdown & Limit and MAC
address tracking with syslog & snmp notification
,Multicast traceroute.
Should have scheduled archiving / uploading of
configuration and system log to a central server
Switch should have have variable fan speed control
for the energy efficiency .
5
Energy Efficiency
6
Automation,
Serviceability and
Manageability
Switch should have Simple Network Management
Protocol (SNMP): complying with SNMPv1, v2c, and
v3 with comprehensive collection of MIBs., The switch
should have mechanism for variable fan speed,
Should be SDN capable with Open stack support and
Open Flow API
support, Should support IEEE
P802.1Qaz
Should support Embedded event manager or
equivalent scripting system that can detect network
events and automatically take action, such as
executing commands or sending an Syslog event /
Snmp trap.
Switch should be SDN capable with Open flow
support
Switch should support IEEE 802.3az energy saving.
7
Environmental
Condition
Switch should have Operating temperature: 32 to
122°F (0°C to 50°C).
Switch should have Operational relative humidity: 10
to 90%, non- condensing.
8
Standard
Certification
9
OEM Criteria
&
Switch should have ETSI EN 300 ,WEEE,CSA
22.2,FCC
All the switches , Wireless controller , Access Points
and the fiber modules should be from the same OEM .
The OEM should have R&D center in India . The OEM
should have atleast 2 RMA depot in India and should
have India Toll free number with India TAC center reflected on the official website
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 18 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-38 8 Port Manageable Network Switch
SL
Specification
Non Blocking architecture
1
Architecture
Switch should support stacking up to 8 switches or
more with stacking bandwidth of 40Gb/s per switch.
Compliance Yes/No
Should support internal/ external redundant PSU
The switch should have 12 x 10/100/1000Base t ports
with 4x 1000x SFP ports .
The switch should be upgraded to 4 x SFP+ ports in
future without changing the base hardware . Should
have min 2x Stacking port with min 40 Gbps stacking
bandwidth from day 1 .Stacking should be ready from
day 1 with accessorries /cables.Stacking mechanism
could be achieved over a diversified location as
minimum 800 Meters .
Switch should have dedicated 1 x 10/100/1000 BaseT
port for Out of band Management port.
2
Performance &
Scalability
Switch should have switching fabric performance of
minimum 100Gbps switch fabric.
Switch should have forwarding rate of 77 Mpps
Switch should have 16K MAC entries table.Should
have 8 Hardware QOS Queues per port ,OS should
support individual process (eg ssh , snmp, telnet, dhcp
etc) restart to prevent reboot in case of Software
Process Crash by running processes on top of Kernel.
3
Layer 2, IP v4
& IP v6
Switch should have IEEE 802.1Q VLANs and trunks.
Switch should have IEEE 802.1ak MVR,Vlan Trunking
Protocol (VTP) OR equivalent for dynamic vlan
creation
Switch should have IEEE 802.1AB Link Layer
Discovery Protocol LLDP
Switch should have Routing Information Protocol
Version 2 (RIPv2) and RIPng from day 1 , Scalable to
OSPF
Switch should have Policy-based routing (PBR) for
IPv4 and IPv6.Should have traffic rate limiting with
Configurable bandwidth granularity of 8 KBps
Switch should be upgradeable to Open Shortest Path
First (OSPF) and VRRP.Should support less than 50
Millisecond convergance for ring based architecture
based on RFC 3619/REP/ERPS/G.8032 etc
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 19 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
4
Network-based
availability
&
Security
Features:
Switch should have Port, vlan, IPv4, IPv6, and time
based Access Control Lists for both directions
Switch should support creation of minimum 1000
number of Access Control Lists on each Port, vlan,
IPv4 & IPv6.
Switch should have Ethernet OAM : IEEE 802.1ag
Layer 2 Ping & traceroute, Multicast traceroute, Should
support AVB to ensure set of standards that provide
the means for highly reliable delivery of low- latency,
time-synchronized AV streaming services through
Layer 2 Ethernet networks,Should have SSH-2, SCP,
SFTP for secure management ,Should have MAC
security – Lockdown & Limit and MAC address
tracking with syslog & snmp notification ,Mul.ticast
traceroute.
Should have scheduled archiving / uploading of
configuration and system log to a central server
5
Energy
Efficiency
Switch should have have variable fan speed control for
the energy efficiency .
6
Automation,
Serviceability
and
Manageability
Switch should have Simple Network Management
Protocol (SNMP): complying with SNMPv1, v2c, and
v3 with comprehensive collection of MIBs., The switch
should have mechanism for variable fan speed,Should
be SDN capable with Openstack support and
OpenFlow API
support, Should support IEEE
P802.1Qaz
Should support Embedded event manager or
equivalent scripting system that can detect network
events and automatically take action, such as
executing commands or sending an Syslog event /
Snmp trap.
Switch should be SDN capable with Open flow support
Switch should support IEEE 802.3az energy saving.
7
Environmental
Condition
8
Standard
&
Certification
9
OEM Criteria
Switch should have Operating temperature: 32 to
122°F (0°C to 50°C).
Switch should have Operational relative humidity: 10 to
90%, non- condensing.
Switch should have ETSI EN 300 ,WEEE,CSA
22.2,FCC
All the switches , Wireless controller , Access Points
and the fiber modules should be from the same OEM .
The OEM should have R&D center in India . The OEM
should have atleast 2 RMA depot in India and should
have India Toll free number with India TAC center reflected on the official website
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 20 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-39 48 port Manageable Network Switch
SL
Specification
Non Blocking architecture
Compliance Yes/No
Switch should support stacking up to 8 switches or
more with stacking bandwidth of 40Gb/s per switch.
Should support internal/ external redundant PSU
The switch should have 48 x 10/100/1000Base t ports
with 8x 1000x SFP ports .The switch should pump min
740 Watt PoE/PoE+ power to power up the PD .
1
Architecture
The switch should be upgraded to 4 x SFP+ ports in
future without changing the base hardware . Should
have min 2x Stacking port with min 40 Gbps stacking
bandwidth from day 1 .Stacking should be ready from
day 1 with accessorries /cables.Stacking mechanism
could be achieved over a diversified location as
minimum 800 Meters .
Switch should have dedicated 1 x 10/100/1000 BaseT
port for Out of band Management port.
Switch should have switching fabric performance of
minimum 176Gbps switch fabric.
2
Performance &
Scalability
Switch should have forwarding rate of 130 Mpps
Switch should have 16K MAC entries table.Should
have 8 Hardware QOS Queues per port ,OS should
support individual process (eg ssh , snmp, telnet, dhcp
etc) restart to prevent reboot in case of Software
Process Crash by running processes on top of Kernel.
Switch should have IEEE 802.1Q VLANs and trunks.
Switch should have IEEE 802.1ak MVR,Vlan Trunking
Protocol (VTP) OR equivalent for dynamic vlan
creation
Switch should have IEEE 802.1AB Link Layer
Discovery Protocol LLDP
3
Layer 2, IP v4
& IP v6
Switch should have Routing Information Protocol
Version 2 (RIPv2) and RIPng from day 1 , Scalable to
OSPF
Switch should have Policy-based routing (PBR) for
IPv4 and IPv6.Should have traffic rate limiting with
Configurable bandwidth granularity of 8 KBps
Switch should be upgradeable to Open Shortest Path
First (OSPF) and VRRP.Should support less than 50
Millisecond convergance for ring based architecture
based on RFC 3619/REP/ERPS/G.8032 etc
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 21 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
Switch should have Port, vlan, IPv4, IPv6, and time
based Access Control Lists for both directions
Switch should support creation of minimum 1000
number of Access Control Lists on each Port, vlan,
IPv4 & IPv6.
4
Network-based
availability &
Security
Features:
Switch should have Ethernet OAM : IEEE 802.1ag
Layer 2 Ping & traceroute, Multicast traceroute, Should
support AVB to ensure set of standards that provide
the means for highly reliable delivery of low- latency,
time-synchronized AV streaming services through
Layer 2 Ethernet networks,Should have SSH-2, SCP,
SFTP for secure management ,Should have MAC
security – Lockdown & Limit and MAC address
tracking with syslog & snmp notification ,Mul.ticast
traceroute.
Should have scheduled archiving / uploading of
configuration and system log to a central server
5
6
Energy
Efficiency
Automation,
Serviceability
and
Manageability
Switch should have have variable fan speed control for
the energy efficiency .
Switch should have Simple Network Management
Protocol (SNMP): complying with SNMPv1, v2c, and
v3 with comprehensive collection of MIBs., The switch
should have mechanism for variable fan speed,Should
be SDN capable with Openstack support and
OpenFlow API
support, Should support IEEE
P802.1Qaz
Should support Embedded event manager or
equivalent scripting system that can detect network
events and automatically take action, such as
executing commands or sending an Syslog event /
Snmp trap.
Switch should be SDN capable with Open flow support
Switch should support IEEE 802.3az energy saving.
7
Environmental
Condition
Switch should have Operating temperature: 32 to
122°F (0°C to 50°C).
Switch should have Operational relative humidity: 10 to
90%, non- condensing.
8
Standard &
Certification
Switch should have ETSI EN 300 ,WEEE,CSA
22.2,FCC
OEM Criteria
All the switches , Wireless controller , Access Points
and the fiber modules should be from the same OEM .
The OEM should have R&D center in India . The OEM
should have atleast 2 RMA depot in India and should
have India Toll free number with India TAC center reflected on the official website
9
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 22 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No- NS-42 Core Switch
SL
Specification
Non Blocking architecture
1
Architecture
Switch should support stacking up to 8 switches or
more with stacking bandwidth of 40Gb/s per switch.
Compliance Yes/No
Should support internal/ external redundant PSU
The switch should have 24 x 100/1000Base X ports
with 8x 10/100/1000T ports .
The switch should have min 4 x SFP+ ports in future
without changing the base hardware . Should be
scalable to min 2x QSFP+ ports .Stacking mechanism
could be achieved over a diversified location as
minimum 800 Meters .Should have option to have data
mirroring with distribution switch .2x Switches with high
available mode should be ready from day 1 .
Switch should have dedicated 1 x 10/100/1000 BaseT
port for Out of band Management port.
2
Performance &
Scalability
Switch should have switching fabric performance of
minimum 296Gbps switch fabric.
Switch should have forwarding rate of 220 Mpps
Switch should have 90K MAC entries table.Should
have 8 Hardware QOS Queues per port ,OS should
support individual process (eg ssh , snmp, telnet, dhcp
etc) restart to prevent reboot in case of Software
Process Crash by running processes on top of Kernel.
3
Layer 2, IP v4
& IP v6
Switch should have IEEE 802.1Q VLANs and trunks.
Switch should have IEEE 802.1ak MVR,Vlan Trunking
Protocol (VTP) OR equivalent for dynamic vlan creation
Switch should have IEEE 802.1AB Link Layer
Discovery Protocol LLDP
Switch should have Routing Information Protocol
Version 2 (RIPv2) and RIPng from day 1 , Scalable to
OSPF , Should support MPLS , SyncE,BGP.
Switch should have Policy-based routing (PBR) for
IPv4 and IPv6.Should have traffic rate limiting with
Configurable bandwidth granularity of 8 KBps
Switch should be upgradeable to Open Shortest Path
First (OSPF) and VRRP.Should support less than 50
Millisecond convergance for ring based architecture
based on RFC 3619/REP/ERPS/G.8032 etc
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 23 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
4
Network-based
availability
&
Security
Features:
Switch should have Port, vlan, IPv4, IPv6, and time
based Access Control Lists for both directions
Switch should support creation of minimum 1000
number of Access Control Lists on each Port, vlan,
IPv4 & IPv6.
Switch should have Ethernet OAM : IEEE 802.1ag
Layer 2 Ping & traceroute, Multicast traceroute, Should
support AVB to ensure set of standards that provide
the means for highly reliable delivery of low- latency,
time-synchronized AV streaming services through
Layer 2 Ethernet networks,Should have SSH-2, SCP,
SFTP for secure management ,Should have MAC
security – Lockdown & Limit and MAC address tracking
with syslog & snmp notification ,Mul.ticast traceroute.
Should have scheduled archiving / uploading of
configuration and system log to a central server
5
Energy
Efficiency
Switch should have have variable fan speed control for
the energy efficiency .
6
Automation,
Serviceability
and
Manageability
Switch should have Simple Network Management
Protocol (SNMP): complying with SNMPv1, v2c, and v3
with comprehensive collection of MIBs., The switch
should have mechanism for variable fan speed,Should
be SDN capable with Openstack support and
OpenFlow API
support, Should support IEEE
P802.1Qaz
Should support Embedded event manager or
equivalent scripting system that can detect network
events and automatically take action, such as
executing commands or sending an Syslog event /
Snmp trap.
Switch should be SDN capable with Open flow support
Switch should support IEEE 802.3az energy saving.
7
Environmental
Condition
Switch should have Operating temperature: 32 to
122°F (0°C to 50°C).
Switch should have Operational relative humidity: 10 to
90%, non- condensing.
8
Standard
Certification
9
OEM Criteria
&
Switch should have ETSI EN 300 ,WEEE,CSA
22.2,FCC
All the switches , Wireless controller , Access Points
and the fiber modules should be from the same OEM .
The OEM should have R&D center in India . The OEM
should have atleast 2 RMA depot in India and should
have India Toll free number with India TAC center reflected on the official website
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 24 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
BOQ Item No NS-43-Access Point (Wi-Fi)
8.2
WLAN solution should provide features that provides other management
functions including firmware push and statistics
8.3
Access points must support autonomous mode
8.4
Must support telnet and/or SSH login to APs directly for troubleshooting
flexibility
Power
10.1
11
Integrated PoE Support
11.1
QOS Support
11.2
11.3
The Access Points should support WMM,WMM-UAPSD,802.1p,Diffserv
and TOS
Support for Voice-over-wireless LAN (VoWLAN) quality of service (QoS)
ensures toll quality, even with many simultaneous calls on a single access
point.
11.4
Access point should support 802.11 DFS
Solution requirements
12.1
12.2
13.3
The AP should be capable of working as a virtual controller for location
where the number of AP's is less than 64
AP's configured as Virtual Controller should also perform the function of an
AP.
Access points must provide automatic redundancy in case a site controller
fails
Certification
13.1
Wi-Fi Alliance (WFA) certified 802.11 a/b/g/n/ac
13.2
Access points must have WiFi Alliance certification for WPA2 Enterprise
BOQ Item No NS-44- Wireless Controller HA (Wi-Fi)
Sl.No
Description
Compliance Yes/No
OEM Should be present in the Gartner report for
wired & wireless networking
1
Major Feature
2
Architecture
3
Interfaces
4
Scalability
Proposed Solution Controller & AP should be of the
same OEM.
WLAN Controller should be Hardware appliance 1U
Rack mountable /Softaware Based based It should
be supplied 60 AP licenses for the campus. If
Software based , hardware and OS to be specified
and supplied . It should Support Cloud based control
if required without upgrade .
It should have 4x1000Base-T interfaces.
Controller shall be capable of supporting 500 AP’s
with license upgradeability.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 25 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
Should support e dual-band capable clients to the 5
GHz band on dual-band access points.
Should balance wireless clients across APs on
different channels, based upon the client load on the
APs.
5
WLAN
Features
Should support internal DHCP server.
WLAN Solution Layer 3 roaming and mobility that
allows a client to roam between APs on the same
network but different client subnets, while preserving
its IP address and existing data sessions.
6
Simple Central
Management
Unified
access,
policy,
configuration,
and
management for thousands of devices
Web-based administration with HTML5enhanced graphical user interface
User group policies can be applied network wide or
to individual devices and enforced consistently
across both wireless and wired networks
Powerful policy template feature enables updates to
groups of APs, branch routers, and switches with a
few clicks
Simple centralized firmware upgrades with
distributed download functionality to decrease WAN
utlilzation & download time
Staged configuration and auto-provisioned image
updates ensure devices are updated
7
8
Network Policy
features
RF
Planning
and
Visualization
WLAN Controller shall have inbuilt capability to
inspect all traffic from each user session and allow or
deny any traffic that does not satisfy specified
policies.
WLAN controller shall provide identity-based controls
to enforce application-layer security and prioritization.
WLAN solution shall be capable of controlling
bandwidth per user, per VLAN/SSID etc.
Network maps with integrated aerial views and
automatic floor planning enable easy visualization of
topology and status
Real-time heat-maps show RF propagation within a
network
State-of-the-art Planning Tool with aerial maps, multifloor auto-placement, coverage maps, and options to
clone buildings and floors
Built-in client and rogue location detection and
placement on a floor plan
Spectrum analysis to detect and identify sources of
Wi-Fi interference
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 26 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
Should prevent students/users connecting to rogue
AP and also prevent an outside user trying to
connect to campus WLAN.
9
WLAN
Security
10
Granular
Control
11
Reporting/
Monitoring
12
Environmental
Specifications
Should prevent Ad-hoc connections (i.e. clients
forming a network amongst themselves without an
AP)
Should prevent windows bridge (i.e. client that is
associated to AP is also connected to wired network
and enabled bridging between two interfaces)
Teacher View application included to monitor and
redirect student wireless clients during class time
Application Q0S and firewall with detailed user and
device context-based policies
Configuration of cloud proxy to split Internet and
corporate VPN traffic with integration to Web sense
SaaS
Configuration of L2 and L3 IPsec VPNs
Automatic and flexible IP address allocation and
distribution across entire remote branch network
Dashboard widgets organized into pre-defined or
customizable perspectives
Bandwidth network bandwidth control
Real-time monitoring of alarms and events
Operating temperature: 32 to 104°F (0 to 40°C)
Storage temperature: -4 to 158°F (-20 to 70°C)
Relative humidity: 5% - 95% (noncondensing)
BOQ Item No NS-45- Unified Threat Management System
Sr.No
i.
Features Required Parameters
Firewall through putshould be support 3.5Gbit/s
ii.
VPN throughput should besupport 700Mbit/s
iii.
IPS throughput should be Support 1.3Gbit/s
iv.
Antivirus throughput (proxy) should be support 375Mbit/s
v.
Concurrent connections should be support 2 million
vi.
Ethernet interfaces (copper) should be support 8xGE
vii.
Network Protection should be minimum 3 year subscriptions for
IPSec/SSL VPN, Intrusion Prevention, DoS Protection
Email Protection with 3 yrs. Subscriptions
viii.
ix.
Compliance
Web Protection should be minimum 3 yrs. Subscriptions for URL
Filtering, Application Control, Dual Engine Antivirus
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 27 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
2.4
S.H. – IV – TELEPHONE SYSTEM
BOQ Item No Ns-46- IP TELEPHONE SYSTEM
K.
IP High End Phone
1
SDRAM – 16 MB
2
FLASH – 4MB
3
LCD – 320X240 (2.4 inch) Color LCD Display
4
SIP lines – minimum 4
5
Supported Codec (G.711,G.723.1,G.729AB,G.722)
6
Should support latest SIPover UDP/TCP/TLS
Should support basic call features eg- Mute / Unmute (microphone) ,
Call Hold / Resume , Call Waiting , Caller ID Display , Call Forwarding
(Always/Busy/No Answer) , Call Transfer (Attended/Unattended), Call
Parking/Pick-up , Do-Not-Disturb (per line / per phone) ,three party
conference , Built-in POE ,should have 2 Ethernet port
10/100/1000Mbps ,48 Fast Dial Digital soft Key.
7
BOQ Item No NS-48- EPABX System TDM TYPE
S No
Technical Qualitative Requirements/ Specifications
1.
300 Line IPPBX.Redundant Industrial Grade Server based IPPBX
with hot standby configuration, 300 Analog Users expandable to
15000 Lines
Compliance
(Y/N)
Make &
Model
System Architecture
1.1
The telephony system should be designed with IP at the
Core, Server & Gateway type communications system,
allowing fully distributed IP solutions across data
networks. The system will be server based and it should
support traditional TDM or mixed IP-TDM or full 100% IP
configurations, telephony , gateway , end points & all
telephony application should be from same OEM.It should
support the following devices :(i)
IP Communication Devices e.g. IP Phones, Video
Phones, MultiMedia PCs, SIP phones, Softphones or
H.323 terminal devices etc.
(ii)
Legacy TDM communication devices (Digital and
analog 2 Wire telephone instruments with Caller-ID
1.2
The call control servers should be fully redundant solution
The solution must provide geographical redundancy by
separating the servers over LAN/WAN. I.e. if the server in
the main data center fails, the other server, which is
installed at geographically different location over
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 28 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
Technical Qualitative Requirements/ Specifications
Compliance
(Y/N)
Make &
Model
LAN/WAN should take over the entire communication
network load.
1.3
Call control server / appliance should be Intel based
hardware with necessary configuration to support the
desired expandability. No proprietary hardware is
acceptable. It is desired to have support for virtualization.
Call Server should be from industry standard vendors like
HP/DELL/LENOVO/Cisco. Virtualization technologies i.e.
VMware to be supported for call server with V-Motion. The
solution must be delivered in a virtualized environment,
however for redundancy, two separate physical servers to
be considered.
Call control server / appliance must be 19” rack-mountable
solution & should have following specification.
i. Intel Xeon 2 GHz Processor or higher
ii. Shall have min 8 GB RAM
iii. Shall have dual HDD (min 300GB or higher SAS drive
each) with RAID 1 (SATA is not acceptable)
iv. Dual Gigabit Ethernet Port
v. Shall have DVD+/-RW
vi. Shall have hot swappable duplicated PSU
1.4
1.5
1.6
1.7
1.8
1.9
The system should be capable of supporting analog and
IP Telephones. The IP EPABX system should have the
capability to scale up to 15000 users to achieve the future
capacity without adding any new servers.
The system should manage CAC (Call Admission Control)
mechanisms to optimize the usage of the bandwidth in the
WAN for multi-site configurations.
The system should be capable of supporting a very high
traffic and should support a Busy Hour Completion
(BHCC) of 3, 00,000 per hour.
The IP PBX should be day one ready with full telephony
Feature/Functionality; all necessary hardware should be
provisioned from day one for this. Full SIP (able to
connect 3rd Party SIP Phone & SIP Trunk Public &
Private) capability. The main functions of SIP capability
should provide SIP networking (Public & private) and
support SIP endpoints in a converged communications
network.
All the users to be managed in a single database,
which is managed centrally, no multiple databases &
bundling of Telephony system will not consider to meet
Specification & scalability.
The voice network architecture and call control
functionality should support both SIP & H.323.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 29 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
Technical Qualitative Requirements/ Specifications
Compliance
(Y/N)
1.10
The system should be based on server gateway
architecture with external server running on Linux OS.
1.11
The system should be able to operate with H.323/SIP
compliant device and it should be able to support internal
gatekeeper for the same.
The SIP proxy, SIP registrar should be inbuilt in the
system and should support open SIP stack compliant hard
phones or soft phones also.
The quoted model should be TEC Certified as IPPBX.
Bidder to submit TEC approval certificate along with the
bid
1.12
1.13
1.14
The system should have non blocking architecture at all
levels & must support more than 512 time slot
1.15
The system should support for voice encoding using
following standards:(i)
G.711
(ii)
G.729A
(iii)
G.722
1.16
Call Switching. Internal calls:
uncompressed PCM standard.
1.17
The System should support Network Time Protocol V4.1.2
(RFC 1305) to synchronize the system date/time of
network devices.
The system should be suitable to accommodate both
Decadic Pulse (DP) and DTMF telephones. The system
should support outgoing DTMF transmission even from
Digital phones.
The system should have non blocking architecture at all
levels like System processing, Switching fabric, power
supplies, other resources like DTMF receivers, R2
Receivers, unlimited 3 or more party conference circuits.
VoIP Support. System should support VoIP solutions as
an integral part of the system.
(i)
The system should be fully compliant to VoIP
standards like H.323 and SIP (Session Initiation Protocol).
Vendor to give clear compliance for the requested
standards.
(ii)
The system should be able to operate with any
H.323/SIP compliant device and it should be able to
support internal gatekeeper for the same. If required, it
should be able to inter operate with H.323 standard based
external gatekeepers.
(iii)
The SIP proxy, SIP registrar should be inbuilt in
the system and should support any open SIP stack
compliant hard phones or soft phones.
(iv)
System should support the QOS features for the
VOIP implementation. It should be compliant with both
QOS standards (Layer 2 – 802.1 p/q) and Layer 3Diffserv/TOS).
1.18
1.19
1.20
Based on the
Make &
Model
G.711
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 30 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
Technical Qualitative Requirements/ Specifications
Compliance
(Y/N)
1.21
1.22
2.
IP v6. The solution should have IPv6 support from day one
The proposed system should Support Automatic Route Selection
(ARS) and Least Cost Routing (LCR) features to route the calls
based on priorities related to user profile and network availability,
along the most cost-effective path. This service should be
transparent for users and irrespective of the physical carrier
connection.
1.23 Should provide a cloud-based, enterprise-grade, Communication
Platform thus delivering a free collaborative business application
extending features viz. Instant Messaging/Telephony Presence,
click to call (dial by name, answer, release), Call Log, P2P
Audio/Video/Screen Sharing. The Facility should be available from
day one for all the extensions equipped in the IPPBX.
1.24 The system must support an IP Softphone application that allows
the users to manage their calls from a PC or
MAC/iPhone/iPAD/Android . This user must have access to the full
set of telephony services without any degradation. The voice
should be manage by the multimedia resources of the PC.
System Security
2.1
The System must support Syslog services for both internal and
external command and configuration control accounting with a
minimum of 30 day history.
2.2
The Call Server must be provided adequate protection from
possible virus, worm and Trojan infestation
2.3
2.4
2.5
2.6
The Call Server must be provided adequate protection from
possible virus, worm and Trojan infestation points such as internal
e-mail servers and they must be updated every month. In case
customized hardened linux distributions are being provided this
clause will not be applicable.
The password and access control must include at least :(i) Management console access to be provided by dual role based
authentication (one of user rep and one of administrator rep).
(ii) Management console access must allow only access to level of
viewing of running configuration and status of current configurations
and sys logs.
(iii)
For any configuration changes again a dual role based
authentication system for write access fully integrated with the
management console application for carrying out the authorized
configuration changes must be provided.
(iv)
Logs of all activities to include configuration change,
housekeeping activities and any other action on the system
grouped user wise and specifying the time of activity must be
available for each day.
(v)
Account access authentication/ restriction using external
RADIUS/ LDAP/ AD resources.
Media Gateways should not host services such as proxy, FTP or
local dynamic routing except those required for software Upgradation /backup etc. to prevent exploitation in Distributed Denial
of Service attacks.
IP Phones should not support direct, external initiated, connections
via HTTP, telnet, FTP, TFTP or any other protocol as means to
prevent distributed Denial of Service attack exploitation, except
those required for software Up gradation/backup etc.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 31 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
3.
Technical Qualitative Requirements/ Specifications
2.7
IP Phone must support 802.1 x (EAP-MD5 or better) for
authentication and access control to the network, this mechanism
must allow the user to be connected to the call server once he has
passed the authentication process, not before.
2.8
The system should have the capability to, based on standard
mechanism (such as 802.1Q and DHCP), assign automatically the
corresponding voice VLAN number to the IP station clients during
IP station initialization, allowing for the separation of voice and data
traffic at IP station.
2.9
Optional Commercial grade optional encryption security with
minimum 128 bit key security for both signaling and voice with in a
node for all IP subscribers – IP subscriber communications.
2.10
Optional Commercial grade optional secrecy with minimum 128 bit
key encryption security for both signaling and voice for inter-node
communication between same type of exchs over IP trunks in
which all traffic between analog/digital/IP over the IP trunk must be
encrypted for both signaling and data.
2.11
System should use randomly generated keys derived from base
keys for every voice and signaling session established by the
system.
Compliance
(Y/N)
System Management
3.1
The system should support a dedicated management
server/platform that will be based on the latest technologies. This
server should support a minimum of five or more clients having
different access rights to the applications.
3.2
The Management platform should support to provide web access
allowing the administrator to manage the system to use any PC
with an internet browser.
3.3
The management platform should support the following tasks :-
3.4
(i)
(ii)
Configuration and programming
(aa) Services, users, categories and all system
parameters and features.
(ab) Provide centralized management in local or remote
environments of a single system or a network.
(ac) The network manager will be able to quickly and
easily edit,
create
or
delete
any
subscriber
profile/network object by the use
of
import/export functions and multiple operations.
Faults and Alarms management
(aa)
All the incidents and fail reports generated by the
system itself informing date, hour and severity.
(ab) This module must be able to centralize the alarms
and Events of the System and give colors according to
the
severity level of the alarm.
(ac) Notify an alarm depending on the severity level
sending an e-mail or activating a script performing
a
specific action.
(ad) Register and generate statistics for the alarms and
events in the network on a daily basis.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 32 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
Technical Qualitative Requirements/ Specifications
Compliance
(Y/N)
(iii)
Fault diagnosis Generate reports and graphics about the
statistics of the alarms.
(iv)
Accounting of external calls generated by the users
including cost, date, hour. Must provide different options to group
the monitoring of the calls (cost center, extension number, trunk,
user, city/area associated to dialed numbers). IP PBX system
should have buffer of last 2500 tickets of call details in case of Call
billing system/ management system failing
(v)
Directory module Should support Directory module to
manage the telephone directory. This must be LDAP compatible
and the exchange directory should be available on web. The LDAP
server and web server application should be integral to the
exchange synchronized with other directory applications, must also
allow web access and provide information on all desktops allowing
click to call features to the users.
(vi)
Web Interface to Directory The exchange directory
supported should be available on web. The LDAP server and web
server application should be integral to the exchange. This feature
should be available for all type of users extensions.
(vii)
Integrated Directory. It shall be possible to provide display
equipped voice terminals with access to system directory on digital
and IP phones. Also System should support internal and external
LDAP directory. Any internal user can use it by browsing the URL
link from his laptop/PC to see the directory and dial the required no
by selecting under LDAP directory.
(viii)
Call Metering and Accounting The log of local to trunk call
in both directions (incoming as well as outgoing) should be
maintained in the exchange in the hard disk.
(ix)
Performance of Trunk operators
The system should
support report clearance of calls by operators and evaluate
performance index of each operator.
(x)
Reports
The management platform should support to
allow the administrator to generate reports and graphics of the
activity per period of time in terms of traffic, accounting and alarms
and giving the possibility to generate statistic of all this analysis.
Those reports must be predefined but the option to personalize the
reports must be also available. These reports should be exportable
in HTML, pdf, excel and LDAP (.ldif) formats.
(xi)
Monitoring Module which allows the administrator to easily
monitor the accounting thresholds of the users of cost centers in
graphical interface and must allow to send an e-mail or an alarm in
case of threshold crossing.
3.6
Network Topology.
The management server should support an
application that offers a topological view of the all network elements
in graphical form such as main, remote unit and connectivity.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 33 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
Technical Qualitative Requirements/ Specifications
3.7
Compliance
( Y/N )
Security
(i)
Administration users connection directly to the call server
(Console) must be authenticated via server before gaining access to
the call server.
(ii) All management traffic between a remote console/session and
the call server must be secured. (SSH for direct command line
session, HTTPS (SSL) for web sessions, SFTP for file transfer, etc.)
(iii) The management platform must provide Role based account
management to define the different levels of administrator access
depending on specific function responsibility.
4.
System Survivability
4.1
The system should offer maximum availability, with the switchover of
call control processing functions to an alternate or redundant
processor in the event of significant fault. The redundancy scheme
should conform to the model used in most computer systems: the
complete "mirroring" of the information (both static and dynamic
data.) The switch over between 2 call servers in LAN or WAN
location over L2 or L3 Network should not interrupt existing and
established communications to include all analog, digital, hard, soft
and Video IP Phones. The complete set of programs and software
modules must be duplicated in real time. In case of failure of the
main Server (hardware or software), the standby Server (emergency
mirror) must take over the control of communications
instantaneously.
4.2
All critical resource elements (call server, hard disks, data bases, IP
interfaces, DSP resources, clocking sources, Processor, RAM, Tone
generators, All the IO ports – serial and Ethernet TCP/IP ports,
control cards, Ring generators, resources like DTMF receivers, Tone
detectors etc.) must be redundant and in a hot-standby
configuration.
4.3
Remote Media Gateway should support survival mechanism that
allows them to maintain 100% of the telephony services for their
users, in case of failure in the WAN links where the signaling with
the call server drops.
4.4
The management platform must provide a backup mechanism for all
critical system information in a both manual and an
automatic/schedule archival and a Disaster Recovery Mechanism.
Replacement of cards without switching off exchange (hot
swappable) including the control cards and peripheral/interface
cards.
All the tone generation and tone detection should be local to the
gateway.
The system should be able to restart automatically without human
intervention when the external ac power supply is resumed after
complete power failure i.e Even after batteries are discharged.
4.5
4.6
4.7
4.8
The call server should support the two or more different
Geographically locations more than 10 Kms in the network.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 34 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
5.
Technical Qualitative Requirements/ Specifications
Compliance
( Y/N )
Physical
5.1
6.
Call Server Should support hardware for 5000 subscribers &
expandable up to 15000 subscriber ports.
5.2
Should have minimum 08 universal slots in single cabinet/chassis.
5.3
System shall have backup batteries powering it for 4 hrs thru
external UPS.
5.4
Environmental Conditions
The equipment offered shall be capable of maintain its guaranteed
performance when operating continuously for 24 hours a day and
365 days a year under the following environmental conditions:(i)
Operating temperature : 0 to 45 degree C.
(ii)
Storage -5 degree C to +45 degree C.
(iii)
Humidity 20% to 80% without condensation
5.5
The exchange cabinet should have top/side fans (integrated with
system) for cooling the system rack/cabinet.
5.6
Must have universal slots and cards should be interchangeable
without switching off the exchange or removing power supply for the
shelf.
System Features
6.1
Numbering Scheme The IP PBX should be suitable for up to 8
digit extension numbering scheme. This numbering scheme
should be flexible. System should also allow mixed numbering
scheme.
6.2
The system should provide distinctive ringing for internal calls,
junction calls, auto call backs, back up service and emergency
reporting service.
6.3
The system should support the attribution of an external number
DDI or individual line or a bundle head to a trunk, a bundle, an
attendant, a group of attendants, a subscriber, a group of
subscriber or virtual equipment. The unanswered DDI
communication can overflow, to Attendant or attendant group,
Local subscriber, Network subscriber, Voice mailbox, automated
attendant, abbreviated number, External number.
6.4
The proposed system should support automatic route selection
(ARS) and least cost routing (LCR) features to route the calls
based on priorities related to user profile, tariff, and network
availability, along the most cost-effective path. This service will be
transparent for users and irrespective of the physical carrier
connection.
6.5
Voice guidance for Telephone features to be offered as standard.
6.6
DTMF and Busy Tone Resources As many busy tone detectors
are to be offered as the number of trunks.
6.7
Basic Telephone Features
(i)
Abbreviated dialing, Appointment reminder, Automatic callback on busy trunk/bundle/network link, Automatic DISA,
user authentication, call forwarding unconditional on busy/no
reply to extension, hunting group, Voice mail, operator,
paging etc.
(ii) Immediate forwarding Call pick-up. Call parking, Call tracing,
Call waiting indication/ voice prompt.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 35 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
Technical Qualitative Requirements/ Specifications
(iii)
(iv)
Compliance
( Y/N )
Calling line identification restriction for internal calls Camp on
busy telephone/hunting group/voice mail, Controlled private
call by Pin code and password.
Do not disturb, Dynamic call baring General night service
Hunting group (fix head cyclic, longest idle time, parallel)
(v)
Internal/external music on hold internal/external inquiry call
individual hold instrument locking to prevent the outgoing.
(vi)
(vi)
28 Party Meet-me & Add-on Conferencing
Last internal/external number redial, Personal code
modification, Priority call, Priority cut in, Store and redial
external number, Transfer in conversation on free/busy
telephone.
6.8
7.
CLI coming in from ISDN PRI trunks should be displayed on
Analog Telephones, Digital Telephones and IP Telephones.
6.9
External Holding Tone The offered system should be ready to
accept music on hold from an external PC of CD player.
System Network Support
7.1
8.
Should Support Q SIG standards over IP/ TDM/ WAN trunks.
(i)
Heterogeneous, open numbering plan.
(ii)
Calling/Connected Line Identification Presentation and
Restriction.
(iii)
Calling/Connected Name Identification Presentation and
Restriction.
(iv)
Call Forwarding Unconditional, Busy, No Reply ,Call
Transfer.
(v)
Call Completion to Busy Subscriber, on No Reply, call
Offer.
7.2
The system should have options to network over any of MPLS, IP,
ISDN
7.3
The system must support the following external telephony interface
signaling:(i)
E1 CCS PRI
(ii)
E1 CAS (R2 MFC )
(iii)
ISDN PRI (ETSI)
(iv)
Analog Loop Start and Ground Start
Voice Mail Features
8.1
General.
The system should support a software based
voice mail of the same OEM, offering the best interactivity with
user. The voice mail must work as a centralized resource in case
remotes are connected to the main exchange.
8.2
The Voice Mail server should be based on industry standard
server or could be based on OEM server hardware. Card based
or 3rd party Voice Mail solution are not Acceptable/Disqualified
8.3
Service Support
(i)
Must support Voice messaging features allowing the
owner of a mailbox to send messages to other mailbox users,
whether they are part of the same system or remote users.
(ii)
Should support Automated attendant (automatic
switchboard) features allowing the voice mail system to act like an
attendant: answer incoming calls, transfer them to a requested or
predefined number or mailbox, using addressing by name or by
number.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 36 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
S No
Technical Qualitative Requirements/ Specifications
(iii)
Shall support e-Messaging service, allowing mailbox
owners to access their voice mail from a remote PC (e-mail client)
via the IP network.
(iv)
Should support E Mail Messenger - A client-server
application dedicated to Lotus Notes and Microsoft Outlook for
voice message manipulation right from the e-mail client.
Mailboxes and Access Control.
(i)
Number of mailboxes as per requirement.
Voice Messaging System.
(i)
Call answering or call/record answering function with time
stamp.
(ii)
Customization of an announcement.
(iii)
Call forwarding to the voice mail.
(iv)
System should support on line live conversation
recording.
(v)
Message notification.
8.4
8.5
9.
10.
Compliance
( Y/N )
Analog Subscriber card.
9.1
9.2
9.3
10.
1
Must support 08/16 or more ports
Each port should support CLIP features (FSK or DTMF)
Loop Resistance >700 ohms.
Digital Subscriber card.
(i)
Must have 08/16 or More ports.
(ii)
(iii)
(iv)
11
11.1
Each port should support CLIP features (FSK or DTMF).
Loop resistance > 400 Ohms
Provide digital ports for connecting digital telephones,
attendant consoles etc.
IP Phone – Should be from same OEM as IPPBX (Type-1 – 50 Nos.
Required)
(i)
(ii)
(iii)
(iv)
(v)
(vi)
(vii)
(viii)
(ix)
(x)
(xi)
(xii)
Visible area: 2.4 inches 128x64 pixels graphical
Black/White LCD display. Viewing area (WxH):
54.8x28.5 mm (2.15 x 1.12 in), LCD Backlight.
Gigabit Ethernet 10/100/1000 connectivity for LAN and PC
Class 2 Power over Ethernet (IEEE 802.3af), Energy
Efficient Ethernet 802.3 az support
Full-duplex speakerphone, acoustic echo
Cancellation
Wideband comfort handset
Wideband G722, G711 (A-law and Mu-law), G729 AB, voice
activity detection (VAD),
comfort noise generation (CNG)
SIP Survivability
Support DHCP and static IP
QoS support: IEEE 802.1p/Q tagging (VLAN), Layer 3
TOS, and DSCP
IEEE 802.1 AB/LLDP-MED client (automatic VLAN
acquisition, PoE management, inventory information)
Up to 6 programmable soft keys with LED, 6 contextual keys
around the screen programmable lighted keys, Numeric to
alpha keypad: To switch to alpha character and perform dial
by name,for example.
Function Keys: On/off hook, dial pad, mute with LED,
volume keys ±, hands-free with LED,
, redial, message key with LED
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 37 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
12.2
13.
IP/SIP Phone – Should be from same OEM as IPPBX(Type -2 , 200
Nos Required)
(i)
Display: 132 x 64 pixel graphic monochrome
display, 5 lines shown with backlight, View area:
31.5mm X 61mm (1.24 in X 2.4 in)
(ii)
Gigabit Ethernet 10/100/1000 connectivity for LAN
and PC
(iii)
802.3AF Power over Ethernet (PoE) - Class 0
(iv)
2 SIP account keys
• Conference key
• Redial key
• Transfer key
• Hold key
(v)
Audio codec: G.711 (A-law and μ-law), G.723.1,
G.729AB, G.722, Supports VAD, CNG, AEC, AJB,
Volume controls, Mute control
(vi)
• Message key with LED
• Headset key with LED
• Call indication LED
• Cancel key
• 4-way navigation and OK key
(vii)
Mana gement
• Auto-provisioning via FTP/TFTP/HTTP/ HTTPS (for
settings and firmware upgrade/download)
• Configuration via Browser/phone/auto- provisioning
• Support Telnet
• Support LLDP
• Trace package and system log export
(viii)
Support DHCP and static IP
(ix)
QoS
• 802.1p (SIP and RTP QoS)
• DSCP
(x)
Security
• 802.1x
• Support VPN
• VLAN tagging (802.1q)
• Transport Layer Security (TLS)
• Digest authentication using MD5/MD5-sess
• Secure configuration file via AES, encryption
• Admin/user 2-level configuration mode
(xi)
Phonebook
• Individual phonebook (300 entries)
• Enterprise phonebook (800 entries)
• LDAP/XML directory service
(xii)
SIP Telephony
IP Phone Based Operator Console – Should be from Same OEM as IPPBX
(i)
Hardware Based Operator Consoles
Display: 3.5 inch color,
240 x 320 pixels, effective display area
size 70.08 x 52.56 mm2, LD Backlight, Ambient light sensor, back
shell
busy light indicator
Gigabit Ethernet 10/100/1000 connectivity for LAN and PC
Class 2 Power over Ethernet (IEEE 802.3af), Energy Efficient
Ethernet 802.3 az support
Full-duplex speakerphone, acoustic echo
Cancellation
Support for Wideband BLUETOOTH handset
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 38 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
PS1
Wideband G722, G711 (A-law and Mu-law), G729 AB, voice activity
detection (VAD), comfort noise generation (CNG)
Support DHCP and static IP
QoS support: IEEE 802.1p/Q tagging (VLAN), Layer 3
TOS, and DSCP
IEEE 802.1 AB/LLDP-MED client (IPv4/ IPv6, automatic VLAN
acquisition, PoE management, inventory information)
It should be possible to expand the attendant set capacity with
additional key modules providing a maximum of 42 additional
programmable keys. The add-on modules keys must be associated
to an electronic icon and label. Each key should be programmable
as a resource or supervision key. It should be possible for the
system manager. To lock some of the keys.
Magnetic alphabetical keyboard, Adjustable foot stand ranging from
25°
to 60°
Function Keys: On/off hook, dial pad, mute with LED,
volume keys ±, hands-free with LED,
2 personal keys/LED, redial, info and
message with LED
PoE Supply for Video Phones, IP Connectivity across all sites& UPS Supply for Servers, shall
be provided by NID.
PS2
List of Approved IPPBX Makes: Cisco/Avaya/Alcatel-Lucent Enterprise/Unify
PS3
MAF: In case the bidder is not the original manufacturer than authorisation certificate is must
for participating in the tender
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 39 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
Special Submittal regarding IT & Network Integration
1.0
Details to be submitted in Envelope -I.:
1.
2.
3.
Mentioning Make and Model Number of offered products in each category.
Network/Schematic Diagram of proposed Network Solution.
Schematic and Line Diagrams of proposed Back Bone Connectivity Solution of each
proposed Solution.
4. Detailed Support Escalation Matrix, Maintenance and SLA details.
5. Certification/Undertaking document from the OEM for providing ongoing product &
Software services.
6. Authorization to bid from all original Equipment Manufacturer.
2.0
Compliance of Facility management Services:
a) Service Level required should be based on 99.9% uptime. Draft SLA and Escalation
Matrix should be submitted along with the Bid document.
b) The cost of Facility Management Services (FMS) for the Defect Liability Period should
be included in the bid.
c) For facility management services, the National Institute of Design (NID) requires Onsite
Support Engineers at site for complete IT and Network Installation including Providing
Training , Prevention &Brak down maintenance etc.
The facility management should mainly cover but not limited to the Following activities on
24*7*365 basis:
• User Administration
• System Administration
• Server Administration
• Network Monitoring
• Performance management
• Disaster Recovery Management
• Network Management & Administration, Configuration, Setup and maintenance for IT Set up.
3.0
Special Points for Passive Components:
a. All copper & Fiber component should be from single OEM as per the makes given in
the tender documents.
b. All passive components should be RoHS (Restriction of Certain Hazardous
Substances) complied. Declaration-RoHS should be clearly mentioned on datasheet
of each Passive Component.
c. There should be a minimum of 20 years warranty assurance for all supplied
component.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 40 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
d. The manufacturer of Passive component should be a technology development
partner with any of the leading Manufacturer of Active Component.
4.0
Special Points for Active Components:
a. All component should be from same OEMs as per the makes given in the tender
documents.
b. All components should be RoHS (Restriction of Certain Hazardous Substances)
complied. Declaration-RoHS should be clearly mentioned on datasheet of each
Active Component.
c. There should be a minimum of 3 years warranty assurance for all supplied
component.
5.0
Copy of the Memorandum of understanding with manufacturer with the participant
tenderer firm indicating/confirming that the manufacturer will complete the supply
of the tendered items of Equipments at our National Institute of Design (NID) within
the stipulated period of completion i.e. 60 days from the date of start. It is necessary
for supplier to submit said MOU from the manufacturers in Envelop-I alongwith
GCC/SCC/Specification (Volume-I).
6.0
For completing Works, bidder should take in consideration all the cost involved to
complete the work like Chiseling, Conducting, Plastering & Painting etc.
7.0
Bidder has to support the complete system for one year after the completing the
installation and assign one dedicated resource for the same for one year on their
own cost only.
8.0
Bidder should have adequate facilities, manpower and staff for installation testing
and commissioning and can provide after sales services. OEM has to authorize their
System Integrator in this regards stating that they will Support the solution through
their SI including Preventive & Routine maintenance services.
9.0
Coordination shall be in the scope of the successful Bidder & they shall coordinate
with all the concerned agencies & attend the scheduled site meetings for successful
completion of the project.
10.0
There should be a minimum of 3 years warranty assurance for all supplied
component.
11.0
The successful bidder shall also ensure the functionally of the complete integrated
PUC System.
12.0
The required UPS, Data, telephone (ISDN/PRI) & Power points have to be intimated
in the drawings in advance of the desired locations so that they can be provided
through the concerned agencies.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 41 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
13.0
The programming, software & firmware up gradation shall be the responsibility of
successful bidder up to the defect liability period.
14.0
All components should be from OEMs as per the option of the makes given in the
tender documents.
15.0 Time is the strict essence of the contract. Suppliers may take all the
factors/expenditures/consequences involved in completing the works within
stipulated period of the contract like working round the clock, co-ordinating
between different agencies, time taken in approval of samples of materials,
procuring the materials, variation in the items of the works etc. The decision of the
NBCC will be final & binding on the supplier and no claim whatsoever in the matter
shall be entertainable/ payable to supplier by NBCC.
16.0
The rate quoted by the party shall be including all taxes etc. & nothing extra shall be
paid.
17.0
The supplier shall provide, install & commission the Equipment in completion form,
at the designated place and as per direction of Engineer in- Charge. The rates quoted
by tenderer shall be deemed to be inclusive of all expenditure to be incurred in the
activities. No extra payment/claim shall be payable/ entertainable on this account.
18.0
The supplier shall assist the other agencies to fix/connect the electric wires, cables,
connections, equipments etc. in workmanship manner. The rates quoted by the
tenderer shall be deemed to be inclusive of all expenditure to be incurred in such
activities. Nothing extra shall be payable on this account.
19.0
The Rate shall be deemed to be inclusive of all services work within the equipment
planned area as defined in specification of work nothing extra shall be payable
beyond quoted price for making the system successfully operational
20.0
It is the responsibility of the contractor for getting the approval from the local
statutory authorities such as town planning/municipal authorities/electricity
board/ fire departments/Pollution Control Board/third party appointed by client
etc. and other department for the works executed at site as per the approved plans
and designs etc. the statutory fees payable for approval shall be made directly to the
local government departments/ state authorities by NBCC authorities. Other
incidental expenditure it any shall be borne by the contractor and no
reimbursement shall be made for the same.
21.0 GENERAL POINT
a.
The work in general shall be carried out as per the latest applicable
codes/specifications with up to date correction slips, unless otherwise specified in
the nomenclature of the individual item or as specifications shall be carried out as
per approved specifications. In case any item is not covered in any of these
documents, the same shall be carried out as per the latest applicable code in
practice or as per approval of Engineer in Charge of NBCC. Where any portion of
special conditions of contact is repugnant to or at variance with any provision of
the with Instruction to Tender and General Conditions of contract and/or the
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 42 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
other documents forming part of the contract then unless a different intention
appears the provisions of the general conditions of Contract shall the other
documents forming part of the contract only to the extent such
repugnant/variations in the special conditions of contract as are not possible of
being reconciled with the provision with Instruction to Tender of General
Conditions of Contract and/or the other forming part of the contract.
b.
Detail Shop drawing including services requirement for equipment to be prepared
by contractor and got approved from Architect, Engineer-in-charge and Client
representative before executions of the work.
c.
Any modification/ alteration as suggested by Client as per site requirements to be
carried by agencies at his own cost. Noting extra shall be payable on this account.
d.
Payment of material shall be made after receiving the material at site in good
condition as per Specification and the same shall be verified by the Engineer-incharge/ Client.
e.
Quantity mentioned in BOQ are indicative and may vary as per the actual
requirement of project no extra claim due to variation in quantities will be
admissible.
f.
Rates are firm and no revision on any account shall be entertained.
g.
Contractor will supply the material as per priority fixed by Engineer-in-charge and
Client representative.
h.
Contractor shall ensure prior inspection and approval from NBCC/Client of all the
equipment prior to dispatch from workshop.
i.
Contractor will provide onsite warrantee of equipment for a period of 3 years
from the date of handing over of the system complete without any extra cost.
j.
SUPPLY AND INSTALLATION of EQUIPMENTS as per location marks in the
Drawings or as directed by Engineer-in-Charge.
k.
The agencies have to work in coordination with the other agencies working at site,
any damage to the existing structural facilities so that Civil, HVAC, Plumbing,
Electrical, the same has to be rectified by the agency to the entire satisfaction of
Client/ Engineer in charge at no extra cost.
l.
Progress Reports and Schedules The contract shall submit to the Engineer-incharge by the third day of every fortnight two copies of a report two copies of a
report duly updated along with BAR/CPM/PERT chart in an approved performa
showing the progress made in construction of the works during the previous
month.
m.
Contractor will deploy qualified staff for operation of equipment for giving
training to the concerned Hospital staff for initial period of One Year without any
extra cost.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 43 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
n.
Review Meetings during the progress of the works the Contractor or his
authorized representative is expected to participate in the monthly review
meetings and/or any special meetings as instructed by the Engineer-in-charge.
Any revision of the schedule of completion as a result of the review, shall be
submitted by the contractor to the Engineer-in-charge within a week who shall
approved it after due scrutiny. The contractor shall adhere to the revised schedule
thereafter. No additional payment shall be made to the contractor for any multiple
shift work or other incentive methods contemplated by him in his work even
though the NBCC approves the time schedule. The approval of the revised them
schedule shall not in any way relieve the contractor form the terms & conditions of
contract contained elsewhere in the contract documents
o.
Quality Assurance Programme The party shall submit the quality plan for the work
to be executed for approval of Engineer-in-Charge/ Client/ Architect.
p.
Site Documents The following site documents shall maintained by the contractor
at site :a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
Copy of contract documents and drawings.
Computerized bill format
Site Order Book
Material testing registers/ Quality Inspection Reports.
Measurement books on computerized format.
Progress Bar Chart.
Sample approval register
Visitors register
Any other detail and specific requirement as deemed necessary.
Hindrance Register.
21.
Witnessing of Tests by the Engineer-in-charge
The Contractor shall make under the direction and in time presence of Engineerin-charge, such tests and inspections as have been specified or as the Engineer-incharge shall consider necessary to determine whether or not the full intent of
requirements of the specifications and the other related contract documents have
been fulfilled. In case the work does not meet the full intent of the specifications
and other related contract documents it shall be rectified by the Contractor at no
extra cost and the Contractor shall bear all the expenses for any further tests
considered necessary.
22.
During post construction phase the contractor shall be responsible for carrying
out the following activities but not limited to the following :-
(i)
Rectification of the defects promptly as pointed out by NBCC or Owner’s
representative(s) during the Operation & Maintenance period.
(ii)
Submission of “Final Report” of the completion project containing all technical &
other related details.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 44 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
23.
Documents for Supply Items For supply in Part III of BOQ the Supplier shall
submit the following documents to NBCC
a)
b)
c)
d)
e)
f)
g)
24.
Warranty Cards
Manufacturer’s Test Certificate
Any other test certificate from an external laboratory to determine the
Technical Specifications.
Catalogs.
Pollution Control Certificate
Documents required for registration of vehicle with the local transport
authority and other interstate movement of vehicle.
Operation & Maintenance manuals
It is the responsibility of the contractor for getting the approval from the local
statutory authorities such as town planning/municipal authorities/electricity
board/ fire departments/third party appointed by client etc. and other
department for the works executed at site as per the approved plans and designs
etc. the statutory fees payable for approval shall be made directly to the local
government departments/ state authorities by NBCC authorities. Other incidental
expenditure it any shall be borne by the contractor and no reimbursement shall be
made for the same.
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 45 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
TENDER FOR S/I/T/C of IT and Network Integration for National Institute of Design
(NID) at Kurukshetra, Haryana for Department of Industrial Policy & Promotion
(DIPP)
(Manufacturer’s Authorization Form)
(On Manufacturer’s Letterhead, see Clause 9.3(c) of the ITB)
Bidder’s Name and Address:
To:
NBCC (India) Ltd.
RBG (Delhi-I)
NBCC Business Centre, Logix Technova,
8th Floor, Sector-132, Noida
For NATIONAL INSTITUTE OF DESIGN (NID)
Dear Sir / Madam,
WE …….(insert name of the Manufacturer)…….. who are established and reputable
manufacturers of ……..(insert name and/or description of the goods)……. do hereby authorize
………(insert name & address of Bidder)……….. (hereinafter, the “Bidder”) to submit a bid, and
subsequently negotiate and sign the Contract with you for …….(insert name of the package
alongwith the project name)……….. including the above plant & equipment or other goods
produced by us.
We hereby extend our full guarantee and warranty for the above specified goods offered
supporting the supply by the Bidder against these Bidding Documents, and duly authorize said
Bidder to act on our behalf in fulfilling these guarantee and warranty obligations. We also
hereby declare that we and ……(insert name of the Bidder)………. have entered into a formal
relationship in which, during the duration of the Contract (including warranty/defects
liability). We, the Manufacturer or Producer, will make our technical and engineering staff fully
available to the technical and engineering staff of the successful Bidder to assist that Bidder, on
a reasonable and best effort basis, in the performance of all its obligations to the Purchaser
under the Contract.
For and on behalf of the Manufacturer
Signed: _______________________________________________________________
Date: __________________________________
In the capacity of …….. (insert title of position or other appropriate designation)….
(Signature) ......................…………….…..
(Printed Name)
Date:....................
(Designation) ...............……………..........
Place:...................
(Common Seal) ………............................
Note 1. The letter of Undertaking should be on the letterhead of the Manufacturer and should
be signed by a person competent and having Power of Attorney to legally bind the
Manufacturer. It shall be included by the bidder in its bid.
2. Above undertaking shall be registered or notarized so as to be legally enforceable
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 46 of 47
Seal & Signature of Contractor
S/I/T/C of IT and Network Integration for National Institute of Design (NID) at Kurukshetra, Haryana for Department of Industrial
Policy & Promotion (DIPP)
LIST OF APPROVED MAKES
FOR WORKS COVERED UNDER THIS CONTRACT
1)
All materials and products used in the work shall conform to the relevant standards/
specifications and shall be got approved from Engineer-in-charge/Consultant/Client. The
approval of a manufacturer/ vendor shall be given only after review of the sample/specimen by
the Engineer-in-charge/Consultant/Client. The complete system and installation shall also be in
conformity with the "Applicable Codes Standards and Publications".
2)
The Engineer- In-charge/Consultant/Client reserves the right to select any of the brand
indicated in the list of approved make. The tenderer shall quote his rates on the basis of price
of best quality product of the brand/make stipulated in the items of works as described in BOQ,
specifications as well as in the list of approved make. The contractor cannot claim anything
extra if the Engineer In-charge/ Consultant/Client changes the make but within the list of
approved make.
3)
When certain makes are missing in the below list, the make will be decided as per the approval
of Engineer In-charge.
4)
Make indicated in the under mentioned list of Approved Makes is for general guidance of
contractor. Final choice of make & model out of List of Approved Makes shall be of Engineer-in-charge/Architect/ Consultant/Owner.
Sr. No
Equipment Description
A)
CCTV System
Cameras (and housings)
Bosch, Impulse, Pelco
DVR
Bosch, Impulse, Pelco
Operator workstations
HP, Lenevo, Dell
LED Display Unit
LG, Samsung, Panasonic
B)
C)
D)
Approved Makes
Passive IT Infra
UTP Cable
R&M, Systimax, Panduit, Siemon
RJ 45 CAT6 I/O
R&M, Systimax, Panduit, Siemon
UTP Patch Cords
R&M, Systimax, Panduit, Siemon
Jack Panel
R&M, Systimax, Panduit, Siemon
Optical Fiber Cable
Optical Pigtails, Patchcords, LIU, Fiber
Accessories
Racks
R&M, Systimax, Panduit, Siemon
R&M, Systimax, Panduit, Siemon
Open/Closed Racks
WQ, RITTAL, APC
Active IT Components
Switches
Extreme, Cisco, Juniper
UTM
Sophos , Checkpoint , Palo Alto
Media Convertor
Zyxel, Dlink, TP Link
EPABX
Unify, Alcatal, Avaya
E)
UPS
Emerson , APC , Nexus, AAL, Socomec
F)
SOLAR
Novergy , Tata Power, Kirloskar, Adani
INVERTOR
ABB, Delta, SMA
----------------------------------------------------------------------------------------------------------------------------------------Technical Specification
Page- 47 of 47
Seal & Signature of Contractor