HIGH VOLTAGE (22KV) CLAMPMETER
High Voltage Clampmeter is connected with insulation rod, which can be used for
measuring current at high voltage that is upto 22KV, on-line current measurement,
Model KM 8000
also having peak measurement,data storage, and other functions, and its specialy
designed clamp makes it easier for clamping the testing wire by pressing or pulling
back the insulation rod, time-saving and fast, widely used in transformer substation,
EW
N
power plant, industrial and mining enterprises as well as the inspection station and
electrician maintenance departments for electrical current detection and field
electrical operations. It can also replace the H. V. Transforming ratio tester, that is to
detect the high & low current for primary circuit and secondary circuit separately.
The insulation rod is light and convenient, with the advantages of anti-moisture, high
temperature resistance, anti-impact, bending resistance, high insulation, flexibility
and other characteristics.
SPECIAL FEATURES :
?
High Voltage AC Current Measurement.
?
Leakage Current Measurement.
?
Low Voltage AC Current Measurement.
?
On-Line AC Current Supervision.
GENERAL SPECIFICATIONS :
Preliminary Data
Insulation Rod
ï
Display : 4 digit backlight LCD display,
Suitable for dark places also.
ï
Resolution : 0.1 mA
ï
Display LCD Size : 47 x 28.5 mm
ï
Jaw opening size : f
46 mm
ï
Autoranging : 0.1mA ~ 1000A automatic
ï
Test Mode : Clip-on CT, integral mode
ï
Sampling Rate : 2 per second
ï
Memory recall function.
ï
Measuring Scope : 0.1mA ~ 1000A (50/60Hz automatic)
ï
Transmission Method : wireless Transmision, the maximum distance for direct transmission is about 30m.
ï
Circuit Voltage : Test for the circuit below 60KV (operated with insulation rod)
ï
Data Memory : 99 groups, during storage, the symbol “MEM” gives indication, “FULL” mark will flash to
indicate the memory is full.
ï
Peak Measurement : The function of automatic capture and hold the maximum average value, under
general test mode, press “HOLD” button longer till PEAK light is bright, that is start PEAK test function,
also known as peak test.
ï
Data Hold : Under general test mode, press HOLD button to hold data, “HOLD” symbol display.
ï
Overflow display : Outrange display; displayed by “OLA” symbol.
ï
No signal indicator : When the receiver has not received transmit signal, it will display “no- -” signal
dynamically.
ï
Auto Shut Down : In about 15 minutes after booting, the meter will shut down automatically, in order to
decrease the battery consumption.
ï
Battery Voltage : When battery Voltage reduced to 5V, battery low voltage symbol will appear to remind
replacing battery.
ï
Measuring Accuracy (23°C ± 5°C, 80% RH below) :
0.1mA ~ 299mA : ±(1%rdg + 3dgts) 300mA ~ 10.00A : ±(1.5%rdg + 5dgts)
50.0A ~ 199.9A : ±(2%rdg + 5dgts) 200A ~ 600A : ±(3%rdg + 5dgts) ; 601A ~ 1000A : ±(4%rdg + 5dgts)
ï
Operating Temperature & Humidity : -10°C ~ 40; 80% RH below
ï
Storage Temperature & Humidity : -10°C ~ 60; 70% RH below
ï
Insulation Rod Dimensions : f
32mm, 1m/section (5 sections)
ï
Insulation strength : AC 40KV/rms (Between insulation rod and clamp core)
ï
Structure : Anti-Dripping Type II
ï
Power Supply : DC 6V alkaline battery (AAA*4)
ï
Dimension : 76(W) x 255(H) x 31(T)mm
ï
Weight : About 335g (including battery), about 2.5kg (including insulation rod & battery).
ACCESSORIES :
Insulation Rod (1M/section) 5 sections, Carrying Case & User Manual.
All Specifications are subject to change without prior notice
®
ELECTRICAL SPECIFICATIONS : KM 860A
AC CURRENT (TRMS)
Accuracy
Range
Resolution
50-500Hz
500-1KHz
400A
0.1 A
±(3.5% rdg + 25 dgts)
±(3.5% rdg + 35 dgts)
0-1000
1
A
±(3.5% rdg + 30 dgts)
±(3.5% rdg + 40 dgts)
3000A 1000-2000
1
A
±(5.5% rdg + 30 dgts)
±(4.0% rdg + 40 dgts)
2000-3000
1
A
±(6.5% rdg + 50 dgts)
±(5.5% rdg + 60 dgts)
Overload Protection : 3000A DC or AC rms
RESISTANCE
DC CURRENT
Accuracy
Resolution
Range
Range
Resolution
Accuracy
0.1
W
W
400A
0.1 A
±(3.0%rdg + 10 dgts)
6
1
kW
W
0-1000
1
A
±(3.5%rdg + 20 dgts)
60
10
kW
±(1.2%rdg + 10 dgts)
W
3000A 1000-2000
1
A
±(5.5%rdg + 20 dgts)
2000-3000
1
A
±(6.5%rdg + 40 dgts)
600
100 W
600 kW
6
1 kW
MW
60
±(2.5%rdg + 15 dgts)
10 kW
MW
Overload Protection : 3000A DC or AC rms
Overload Protection : 250V DC or AC rms
CAPACITANCE
DIODE & AUDIBLE CONTINUITY TEST
Description
Range
Test Condition
Display read approx.
Forward voltage of diode.
Built-in buzzer sounds if
resistance is less
than 100W
Forward DC current
approx. 0.4mA
Reverse DC Voltage
approx. 2.8V
Open circuit voltage
approx. 0.5V
Range
Resolution
40
nF
10
400
nF
100 pF
4
1
m
F
nF
40
10
m
F
nF
400
100 nF
m
F
±(5.0%rdg + 10 dgts)
±(2.5%rdg + 5 dgts)
1
4000 m
F
Overload Protection : 250V DC or AC rms
pF
Accuracy
±(5.0%rdg + 10 dgts)
±(20.0%rdg + 20 dgts)
m
F
Overload Protection : 250V DC or AC rms
TEMPERATURE
Accuracy
Range Resolution
-20~150°C
-4 ~ 302°F
°C / °F
1°C / 1°F
FREQUENCY
±(3°C + 2)
150 ~ 300°C
302 ~ 572°F
±(3% rdg + 2 dgts)
300 ~ 1000°C
572 ~ 1800°F
±(3.5%rdg + 10dgts)
NiCr-NiSi sensor. Sensor accuracy not included in above specified accuracy.
Overload Protection : 36V DC or AC rms
DUTY CYCLE
Range
Accuracy
Frequency
0.1% ~ 99.9%
±(2.0% rdg + 2 dgts)
<10kHz
Sensitivity : sine wave 0.6Vrms
Overload Protection : 250V DC or AC rms
Range
Resolution
10
Hz
0.01 Hz
100
Hz
0.1
Hz
1000
Hz
1
Hz
10
kHz
10
Hz
100
kHz
100 Hz
1000 kHz
1
10
10 KHz
MHz
Accuracy
±(0.5%rdg + 5dgts)
KHz
Sensitivity : Range of input Voltage : 1.5V ~ 10V, if input
voltage over range, need adjust
Overload Protection : 250V DC or AC rms
All Specifications are subject to change without prior notice
®
An ISO 9001:2008 Company
Navin.com/D.drive/sandeep gupta/New catlog Dec 2011/KM 8000.cdr