Flow
VA 500/ 520
Flow sensors for
compressed air
and gases incl.
temperature
measurement
www.cs-instruments.com
79
Flow
What are the advantages of our flow
measuring technology?
1) (YHQXQGHUSUHVVXUHWKHÀRZVHQsor VA 500 is mounted by means of a
standard 1/2“ ball valve. During mounting
and dismounting the safety ring avoids
an uncontrolled
ejection of the probe
which may be caused by the operating
pressure.
1/2“ mounting thread
mounting depth =
x+y
dA = outer diameter
x = dA
2
1/2“ - ball valve
closed
For the mounting into different pipe
diameters VA 500 is available in the following probe lengths: 120, 160, 220, 300,
400 mm.
Engraved depth
scale for accurate
installation
180
170
y
160
x
6RWKHÀRZVHQVRUVDUHEHLQJPRXQWHG
into existing pipelines with inner diameters
of 1/2“ upwards.
safety ring
The exact positioning of the sensor in the
middle of the pipe is granted by means of
the engraved depth scale. The maximum
mounting depth corresponds with the resprective probe length. Example: VA 500
with probe length 220 mm has a maximum mounting depth of 220 mm.
2) If there is no suitable measuring site
with a 1/2“ ball valve present there are two
simple possibilities to set up a measuring
point:
A Weld on a 1/2“ screw neck
and screw on a 1/2“ ball valve
B Mount spot drilling collar incl.
ball valve (see accessories)
By means of the drilling jig it is possible
to drill under pressure through the 1/2“
ball valve into the existing pipeline. The
GULOOLQJFKLSVDUHFROOHFWHGLQD¿OWHU7KHQ
the probe can be mounted as described
under point A.
3) Due to the large measuring range of
the probe even extreme requirements
to the consumption measurement (high
YROXPHÀRZLQVPDOOSLSHGLDPHWHUVFDQ
be met. The measuring range is depending on the pipe diameter - see table on the
right hand side.
80
B Spot drilling collar
Drilling under pressure
A Screw neck
Flow measuring ranges VA 500 for compressed air (ISO 1217:1000 mbar, 20 °C)
Inner diameter of pipe
VA 500 Standard
(92.7 m/s)
VA 500 Max.
(185.0 m/s)
VA 500 High-Speed
(224.0 m/s)
Inch
mm
Measuring range
from to
Measuring range
from to
Measuring range
from to
1/2“
16.1
DN 15
2.5...760 l/min
3.5...1516 l/min
6.0...1836 l/min
3/4“
21.7
DN 20
0.3...89 m³/h
0.4...178 m³/h
0.7...215 m³/h
1“
27.3
DN 25
0.5...148 m³/h
0.6...295 m³/h
1.1...357 m³/h
1 1/4“
36.0
DN 32
0.9...280 m³/h
1.2...531 m³/h
2.5...644 m³/h
1 1/2“
41.9
DN 40
1.2...366 m³/h
1.5...732 m³/h
3.0...886 m³/h
2“
53.1
DN 50
2...600 m³/h
2.5...1198 m³/h
4.6...1450 m³/h
2 1/2“
71.1
DN 65
3.5...1096 m³/h
5...2187 m³/h
7...2648 m³/h
3“
84.9
DN 80
5...1570 m³/h
7...3133 m³/h
12...3794 m³/h
4“
110.0
DN 100
9...2645 m³/h
12...5279 m³/h
16...6391 m³/h
5“
133.7
DN 125
13...3912 m³/h
18...7808 m³/h
24...9453 m³/h
6“
159.3
DN 150
18...5560 m³/h
25...11097 m³/h
43...13436 m³/h
8“
200.0
DN 200
26...8786 m³/h
33...17533 m³/h
50...21230 m³/h
10“
250.0
DN 250
40...13744 m³/h
52...27429 m³/h
80...33211 m³/h
12“
300.0
DN 300
60...19815 m³/h
80...39544 m³/h
100...47881 m³/h
www.cs-instruments.com
Flow
VA 500 - Flow sensor for
compressed air and gases
7KHQHZ9$IRUÀRZPHDVXUHPHQWRIFRPSUHVVHGDLUDQG
JDVHVRSWLRQDOO\ZLWKGLVSOD\IRUÀRZLQPñKDQGWRWDOÀRZLQ
m³.
Contrary to the previously used bridge circuit the newly
developed evaluation electronics records all measured values
digitally. This leads to a better accuracy also in case of large
measuring spans of 1:1000.
Inner diameter adjustable
via keypad
Special features:
Technical data VA 500
‡ RS 485 interface, Modbus-RTU as a standard
Parameters:
m³/h, l/min (1000 mbar, 20°C) in
case of compressed air resp. Nm³/h,
Nl/min (1013 mbar, 0°C) in case of
gases
Units
adjustable
via keys at
display:
m³/h, m³/min, l/min, l/s, ft/min, cfm,
m/s, kg/h, kg/min
Adjustable
via keypad:
GLDPHWHUIRUYROXPHÀRZFDOFXODWLRQ
counter resettable
Meas.
principle:
calorimetric measurement
Sensor:
7KHUPDOPDVVÀRZVHQVRU
Meas.
medium:
air, gases
Gas types
adjustable
via external
devices
DS 400, DS
500, PI 500
air, nitrogen, argon, nitrous oxide,
CO2, oxygen
Meas.
range:
see table measuring ranges
page 80
Accuracy:
(m.v.: of
meas. value)
(f.s.: of full
scale)
± 1.5 % of m.v. ± 0.3 % of f.s.
on request
± 1.0 % of m.v. ± 0.3 % of f.s.
Operating
temp.:
-30...110 °C probe tube
-30...80 °C housing
Operating
pressure:
up to 50 bar
Digital
output:
RS 458 interface, Modbus RTU,
M-Bus (optionally)
Analogue
output:
4...20 mA for m³/h resp. l/min; on
request:
scaling for cfm,m³/min, l/min, l/s, ft/
min, m/s
Pulse output:
1 pulse per m³ resp. per liter
galvanically separated
‡ Incl. temperature measurement
‡ Integrated display for m³/h and m³
‡ Usable from 1/2“ to DN 1000
ÀH[LEOHPRXQWLQJ
thread G 1/2“
‡ Easy installation under pressure
‡ 4...20 mA analogue output for m³/h resp. m³/min
‡ Pulse output for m³ or M-Bus (optionally)
‡ Inner diameter adjustable via keypad
safety ring
Ø 11.7 mm
‡ Consumption counter resetable
‡ Adjustable via keys at the display: Reference
conditions, °C and mbar, 4...20 mA scaling,
pulse weight
Describtion
Order No.
9$ÀRZVHQVRULQEDVLFYHUVLRQ
Standard (92.7 m/s), probe length 220 mm, without display
0695 5001
Options for VA 500:
Display
Z695 5000
Max. version (185 m/s)
Z695 5003
High Speed version (224 m/s)
Z695 5002
1 % Accuracy of m.v. ± 0,3 % of f.s.
Z695 5005
M-Bus board for VA500/520 and FA500
Z695 5004
Probe length 120 mm
ZSL 0120
Probe length 160 mm
ZSL 0160
Probe length 300 mm
ZSL 0300
Probe length 400 mm
ZSL 0400
Probe length 500 mm
ZSL 0500
Probe length 600 mm
ZSL 0600
Connection cables:
Connection cable, 5 m
0553 0104
Connection cable, 10 m
0553 0105
Further accessories:
CS Service Software for FA/VA 500 sensors incl. PC connection set, USB interface and interface adapter to the sensor
0554 2007
Power
supply:
18...36 VDC, 5 W
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx,
100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A
0554 0110
Burden:
ȍ
Housing:
polycarbonate (IP 65)
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520
0554 0109
Probe tube:
External wall display chart recorder DS 400
0500 4000
SRLQWSUHFLVLRQFDOLEUDWLRQZLWK,62FHUWL¿FDWH
3200 0001
stainless steel, 1.4301
mounting length 220 mm,
Ø 10 mm
M12 – T plug for VA 500/520 to connect several sensors to a M-Bus network or
Modbus network.
020000823
Mounting
thread:
G 1/2“
www.cs-instruments.com
81
Flow
VA 520
7KHDIIRUGDEOHÀRZPHWHUIRUFRPSUHVVHGDLUDQGJDVHV
incl. temperature measurement
R 1/4“ (DN 8)
DN 15
R 3/4“ (DN 20)
DN 25
R 1 1/4“ (DN 32)
DN 40
R 2“ (DN 50)
:LWKDQGZLWKRXWÀDQJH
Intelligent solutions for
DFFXUDWHÀRZPHDVXUHment for compressed air
and gases
7KHQHZDIIRUGDEOHÀRZVHQVRUV9$
work according to the approved calorimetric measuring principle. An additional
pressure and temperature compensation is not necessary. Contrary to the
82
previously used bridge circuit the newly
developed evaluation electronics records
all measured values digitally. This enables
very precise and fast measurements. Due
to the new evaluation electronics all VA
520 have an integrated Modbus output
as a standard. So all parameters can be
transferred via Modbus.
Due to its compact design it is possible to
monitor all compressed air systems from
the compressor to the smallest compressed air tool (1/4“ to 3 inch) with the
www.cs-instruments.com
QHZDIIRUGDEOHÀRZVHQVRU9$
9$ÀRZVHQVRUVDUHDYDLODEOHIRU
larger pipe diameters from DN 50 to DN
1000. Apart from compressed air also
other gases like e.g. nitrogen, oxygen and
CO2 can be
measured.
Flow
Removal of the measuring device without complete dismounting
of the measuring section
1.
In most cases the compressed air is not
free from oil, condensate, dirt and particles.
In the course of time this leads to a soiling
RIWKHÀRZPHWHUVZKLFKPD\FDXVHHUURUV
2.
soiled. In case of compressed air meters
with integrated measuring section the
„measuring device“ cannot be removed.
For this reason an expensive bypass
line is necessary. The design of VA 520
enables the removal and cleaning of
the „measuring device“ with e.g. soap
water without any dismounting of the
measuring section. A closing cap grants
a continuous use of the line for the duration of the cleaning. A bypass line is not
necessary. The alignment pin grants an
accurate installation of the measuring
in measurement or even a total breakdown. device.
7KHÀRZVHQVRUVZKLFKKDYHEHHQRQ
the market up to now generally cannot be
cleaned and will be exchanged if they are
Stationary use
For stationary use there are the following
outputs available for the data transfer to
a building management system or PLC:
P$IRUDFWXDOÀRZ
Pulse output (galvanically separated)
for the total consumption.
3.
Mobile use
%\PHDQVRITXLFNFRXSOLQJVWKHÀRZVHQVRU
can be integrated quickly into the feed hose
of a machine. During the shutdown of the
machine it is possible to determine the leak
UDWHWKHDFWXDOÀRZFDQEHREWDLQHGZKHQ
the machine is running. The power supply
is effected via the power socket by means
of the mains unit. For data recording over a
longer period of time we recommend to use
the compressed air analyzer DS 400 mobile.
4.
Solution for large pipe diameters
7KHDSSURYHGÀRZVHQVRU9$LV
available for pipe diameters of 2“ to
DN 1000. Its constructively sophisticated
design enables the installation into pipes
with nominal diameters up to DN 1000
even under pressure. The installation is
effected by means of standard 1/2“ ball
valve.
www.cs-instruments.com
83
Flow
VA 520 - The advantages at a glance
Display twist able by 180°C
HJLQFDVHRIUHYHUVHÀRZ
direction
NEW: Modbus-RTU output
Display shows 2 values at the
same time:
$FWXDOÀRZLQPñKOPLQ
- Total consumption (counter reading) in m³,l
- resp. temperature measurement
4...20 mA output for actual
ÀRZ
3XOVHRXWSXWIRUWRWDOÀRZ
(counter reading), galvanically
isolated or M-Bus (optionally)
Values indicated in the display turnable by
180°C, e.g. in case of overhead installation
Measuring device removable:
Dismounting of the whole measuring
section is not necessary, no bypass
required
Screw-in thread:
Easy installation into the existing pipeline
due to integrated measuring section
(suitable for 1/4“, 1/2“, 3/4“, 1“, 1 1/4“, 1
1/2“ or 2“ lines)
High measuring accuracy due
WRGH¿QHGPHDVXULQJVHFWLRQ
(inlet and outlet section)
‡ Reset of counter reading
‡ selection of units
Application-technological features of the
Àow sensors VA 520:
‡ The integrated Modbus interface enables the connection to superordinate control
systems like energy management systems, building management systems, SPS,
SCADA, ......
‡ Easy and affordable installation
‡ Units freely selectable via keys at the display m³/h, m³/min, l/min, l/s, kg/h, kg/min,
kg/s, cfm
‡ Compressed air counter up to 1.999.999.999 m³. Reset able to „zero“ via keypad
‡ Analogue output 4...20 mA, pulse output (galvanically separated)
‡ High measuring accuracy also in the lower measuring range (ideal for leakage
measurement)
‡ Negligibly small loss of pressure
‡ Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
‡ Comprehensive diagnosis functions can be read out at the display or by remote
access via Modbus-RTU like e. g. exceeding Max./Min values °C, calibration cycle,
error codes, serial number. All parameters can be read out and changed via Modbus
84
At the touch of a button:
www.cs-instruments.com
‡ zero-point adjustment, leak
ÀRZYROXPHVXSSUHVVLRQ
Application range of
VA 520:
‡ Compressed air balancing,
compressed air consumption
measurement
‡ Leakage air/leak rate determination
‡ Mobile compressed air measurement in front of single machines /
plants
‡ Flow measurement of process gases
like e.g. nitrogen, CO2, oxygen,
argon, nitrous oxide
‡ Flow measurement at nitrogen
generators
Flow
Flow measuring ranges VA 520 for compressed air (ISO 1217:1000 mbar, 20 °C)
Connection
thread
Outer pipe
dia. mm
Inner
pipe
dia. mm
Measuring range
from
to
L
mm
L1
mm
H
mm
H1
mm
A
mm
R 1/4“
13.7
8.9
0.8
90 l/min
194
137
174.7
165.7
15
R 1/2“
21.3
16.1
0.2
90 m³/h
300
210
176.4
165.7
20
Technical data
VA 520
R 3/4“
26.9
21.7
0.3
170 m³/h
475
275
179.2
165.7
20
Parameters:
m³/h, l/min (1000 mbar,
20°C) in case of compressed
air resp. Nm³/h, Nl/min (1013
mbar, 0°C) in case of gases
Units
adjustable via
keys at display:
m³/h, m³/min, l/min, l/s, ft/
min, cfm, m/s, kg/h, kg/min
Meas. principle:
calorimetric
measurement
Sensor:
7KHUPDOPDVVÀRZVHQVRU
Meas. medium:
air, gases
air, nitrogen, argon, nitrous
oxide, CO2, oxygen
R 1“
33.7
27.3
0.5
290 m³/h
475
275
182.6
165.7
25
R 1 1/4“
42.4
36.0
0.7
530 m³/h
475
275
186.9
165.7
25
R 1 1/2“
48.3
41.9
1.0
730 m³/h
475*
275
186.9
165.7
25
R 2“
60.3
53.1
2.0
1195 m³/h
475*
275
195.9
165.7
30
*Attention: Shortened inlet section! Please observe the recommended minimum inlet section (length = 15 x inner diameter)
on site!
Description
Order No.
Stainless
steel
1.4571
Order No.
Stainless
steel
1.4301
9$ÀRZVHQVRUZLWKLQWHJUDWHG³PHDVXULQJVHFWLRQ
0695 1520
0695 0520
9$ÀRZVHQVRUZLWKLQWHJUDWHG³PHDVXULQJVHFWLRQ
0695 1521
0695 0521
9$ÀRZVHQVRUZLWKLQWHJUDWHG³PHDVXULQJVHFWLRQ
0695 1522
0695 0522
9$ÀRZVHQVRUZLWKLQWHJUDWHG³PHDVXULQJVHFWLRQ
0695 1523
0695 0523
Gas types
adjustable via
external device
DS 400, DS 500,
PI 500
9$ÀRZVHQVRUZLWKLQWHJUDWHG³PHDVXULQJVHFWLRQ
0695 1526
0695 0526
Meas. range:
see table at the left
9$ÀRZVHQVRUZLWKLQWHJUDWHG³PHDVXULQJVHFWLRQ
0695 1524
0695 0524
9$ÀRZVHQVRUZLWKLQWHJUDWHG³PHDVXULQJVHFWLRQ
0695 1525
0695 0525
Accuracy:
(m.v.: of meas.
value)
(f.s.: of full scale)
± 1.5 % of m.v. ± 0.3 % of
f.s.
on request
± 1.0 % of m.v. ± 0.3 % of
f.s.
Operating temp.:
-30...80 °C
Option High-pressure version PN 40
Z695 0411
Option 1 % Accuracy of m.v. ± 0,3 % of f.s.
Z695 5005
Special measuring range VA 520
Z695 4006
M-Bus board for VA500/520 and FA500
Z695 5004
Connection cables:
Connection cable 5 m
0553 0104
Operating
pressure:
up to 16 bar
optional up to PN 40
Connection cable 10 m
0553 0105
Digital output:
3XOVHFDEOHIRUÀRZVHQVRUVZLWK0SOXJOHQJWKP
0553 0106
RS 485 interface, ModbusRTU, M-Bus (optionally)
3XOVHFDEOHIRUÀRZVHQVRUVZLWK0SOXJOHQJWKP
0553 0107
Analogue output:
4...20 mA for m³/h resp. l/min
Pulse output:
1 pulse per m³ resp. per liter
galvanically separated
Power supply:
18...36 VDC, 5 W
Burden:
ȍ
Housing:
polycarbonate
Meas. section:
stainless steel, 1.4301 or
1.4571
Mounting thread
meas. section:
R 1/4“, R 1/2“,
R 3/4“, R 1“, R 1 1/4“,
R 1 1/2“, R 2“ external
thread.
Further accessories:
Closing cap for meas. section (Material: Aluminium)
0190 0001
Closing cap for meas. section (Material: Stainless steel 1.4404)
0190 0002
CS Service Software for FA/VA sensors incl. PC connection set, USB
interface and interface adapter to the sensor
0554 2007
Mains unit in wall housing for maximum 2 sensors of the series VA/FA
5xx, 100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A
0554 0110
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520
0554 0109
SRLQWSUHFLVLRQFDOLEUDWLRQZLWK,62FHUWL¿FDWH
3200 0001
M12 – T plug for VA 500/520 to connect several sensors to a M-Bus
network or Modbus network.
020000823
www.cs-instruments.com
85
Flow
VA 520 - The advantages at a glance
Display twist able by 180°C
HJLQFDVHRIUHYHUVHÀRZ
direction
NEW: Modbus-RTU output
P$RXWSXWIRUDFWXDOÀRZ
3XOVHRXWSXWIRUWRWDOÀRZ
(counter reading), galvanically
isolated or M-Bus (optionally)
Measuring device removable:
Dismounting of the whole measuring
section is not necessary, no bypass
required
Display shows 2 values at the
same time:
$FWXDOÀRZLQPñKOPLQ
- Total consumption (counter reading) in m³,l
- resp. temperature measurement
Values indicated in the display turnable by
180°C, e.g. in case of overhead installation
At the touch of a button:
Easy installation into the existing pipeline
due to integrated measuring section and
ZHOGQHFNÀDQJH
(according to EN 1092-1 PN 40)
+LJKPHDVXULQJDFFXUDF\GXHWRGH¿QHG
measuring section (inlet and outlet section)
‡ reset of counter reading
‡ selection of units
‡ zero-point adjustment, leak
ÀRZYROXPHVXSSUHVVLRQ
Application-technological features of the
Àow sensors VA 520:
‡ The integrated Modbus interface enables the connection to superordinate control
systems like energy management systems, building management systems, SPS,
SCADA, ......
‡ Easy and affordable installation
‡ Units freely selectable via keys at the display m³/h, m³/min, l/min, l/s, kg/h, kg/min,
kg/s, cfm
‡ Compressed air counter up to 1.999.999.999 m³. Reset able to „zero“ via keypad
‡ Analogue output 4...20 mA, pulse output (galvanically separated)
‡ High measuring accuracy also in the lower measuring range (ideal for leakage
measurement)
‡ Negligibly small loss of pressure
‡ Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
‡ Comprehensive diagnosis functions can be read out at the display or by remote
access via Modbus-RTU like e. g. exceeding Max./Min values °C, calibration cycle,
error codes, serial number. All parameters can be read out and changed via Modbus
86
www.cs-instruments.com
Application range of
VA 520:
‡ Compressed air balancing,
compressed air consumption
measurement
‡ Leakage air/leak rate determination
‡ Flow measurement of process gases
like e.g. nitrogen, CO2, oxygen,
argon, nitrous oxide
‡ Flow measurement at nitrogen
generators
Flow
Flow measuring ranges VA 520 for compressed air
(ISO 1217:1000 mbar, 20 °C)
Flange DIN EN
1092-1
Measuring
section
Outer
pipe dia.
mm
Inner
pipe dia.
mm
Measuring range
from
to
L
mm
L1
mm
H
mm
H1
mm
ØD
ØK
n x ØL
Technical data
VA 520
DN 15
21.3
16.1
0.2
90 m³/h
300
210
213.2
165.7
95
65
4 x 14
Parameters:
DN 20
26.9
21.7
0.3
170 m³/h
475
275
218.2
165.7
105
75
4 x 14
DN 25
33.7
27.3
0.5
290 m³/h
475
275
223.2
165.7
115
85
4 x 14
DN 32
42.4
36.0
0.7
530 m³/h
475
275
235.7
165.7
140
100
4 x 18
m³/h, l/min (1000 mbar,
20°C) in case of compressed air resp. Nm³/h,
Nl/min (1013 mbar, 0°C)
in case of gases
DN 40
48.3
41.9
1.0
730 m³/h
475*
275
240.7
165.7
150
110
4 x 18
DN 50
60.3
53.1
2.0
1195 m³/h
475*
275
248.2
165.7
165
125
4 x 18
Units
adjustable via
keys at display:
m³/h, m³/min, l/min, l/s, ft/
min, cfm, m/s, kg/h, kg/
min
DN 65
76.1
68.9
4.0
2050 m³/h
475*
275
268.2
175.7
185
145
8 x 18
Meas. principle:
DN 80
88,9
80,9
5,0
2840 m³/h
475*
275
275,7
175,7
200
160
8 x 18
calorimetric
measurement
Sensor:
7KHUPDOPDVVÀRZ
sensor
*Attention: Shortened inlet section! Please observe the recommended minimum inlet section
(length = 15 x inner diameter) on site
Description
Order No.
Meas. medium:
air, gases
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2521
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2522
air, nitrogen, argon, nitrous oxide, CO2, oxygen
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2523
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2526
Gas types
adjustable via
external device
DS 400, DS 500,
PI 500
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2524
Meas. range:
see table at the left
Accuracy:
(m.v.: of meas.
value)
(f.s.: of full scale)
± 1.5 % of m.v. ± 0.3 %
of f.s.
on request
± 1.0 % of m.v. ± 0.3 %
of f.s.
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2525
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2527
9$ÀRZVHQVRUZLWKLQWHJUDWHG'1PHDVXULQJVHFWLRQZLWKZHOGQHFNÀDQJH
0695 2528
Option High-pressure version PN 40
Z695 0411
Option 1 % Accuracy of m.v. ± 0,3 % of f.s.
Z695 5005
Special measuring range VA 520
Z695 4006
Operating temp.:
-30...80 °C
M-Bus board for VA500/520 and FA500
Z695 5004
Operating press.:
up to 16 bar
Optional up to PN 40
Connection cable 5 m
0553 0104
Digital output:
Connection cable 10 m
0553 0105
RS 485 interface,
Modbus-RTU, M-Bus
(optionally)
3XOVHFDEOHIRUÀRZVHQVRUVZLWK0SOXJOHQJWKP
0553 0106
Analogue output:
3XOVHFDEOHIRUÀRZVHQVRUVZLWK0SOXJOHQJWKP
0553 0107
4...20 mA for m³/h resp.
l/min
Pulse output:
1 pulse per m³ resp. per
liter galvanically separated
Power supply:
18...36 VDC, 5 W
Burden:
ȍ
Housing:
polycarbonate (IP 65)
Meas. section:
stainless steel 1.4571
Flanges:
:HOGQHFNÀDQJHDFFRUding to DIN EN 10921, Groove-faced and
tongue-faced on request
Connection cables:
Further accessories:
Closing cap for meas. section (Material: Aluminium)
0190 0001
Closing cap for meas. section (Material: Stainless steel 1.4404)
0190 0002
CS Service Software for FA/VA sensors incl. PC connection set,
USB interface and interface adapter to the sensor
0554 2007
Mains unit in wall housing for maximum 2 sensors of the series VA/FA 5xx,
100-240 V, 23 VA, 50-60 Hz / 24 VDC, 0.35 A
0554 0110
AC adapter plug 100-240 V AC/ 24 V for VA/FA 500/520
0554 0109
SRLQWSUHFLVLRQFDOLEUDWLRQZLWK,62FHUWL¿FDWH
3200 0001
M12 – T plug for VA 500/520 to connect several sensors to a M-Bus network or
Modbus network.
020000823
www.cs-instruments.com
87