VideoJet X10 SN

Network Video Server

en

Installation and Operating Manual

VideoJet X10 SN

VideoJet X10 SN

Table of Contents

3

3.1

3.2

3.3

3.4

3.5

4

4.1

4.2

4.3

4.4

4.5

5.13

5.14

5.15

5.16

5.17

5.18

5.8

5.9

5.10

5.11

5.12

5

5.1

5.2

5.3

5.4

5.5

5.6

5.7

1

1.1

1.2

1.3

1.4

1.5

2

2.1

2.2

2.3

Bosch Security Systems

Preface

About this Manual

Conventions in this Manual

Intended Use

EU Directives

Rating Plate

Safety Information

Electric Shock Hazard

Installation and Operation

Maintenance and Repair

Product Description

Scope of Delivery

System Requirements

Overview of Functions

Connections on the Front Panel

Connections on the Rear Panel

Installation

Preparations

Mounting

Connections

Power On/Power Off

Setup Using the Configuration Manager

Configuration Using a Web Browser

Connecting

Configuration Menu

Basic Mode: Unit Access

Basic Mode: Date/Time

Basic Mode: Network

Basic Mode: Encoder Profile

Basic Mode: Audio

Basic Mode: Recording

Basic Mode: System Overview

Advanced Mode: Identification

Advanced Mode: Password

Advanced Mode: Date/Time

Advanced Mode: Display Stamping

Advanced Mode: Appearance

Advanced Mode: LIVEPAGE Functions

Advanced Mode: Logging

Advanced Mode: Video Input

Advanced Mode: Picture Settings

Installation and Operating Manual

Table of Contents | en

3

13

16

17

11

11

12

19

19

19

20

24

24

40

41

42

44

44

45

35

36

36

38

39

27

27

29

31

32

33

34

35

7

8

8

7

7

7

9

9

9

9

DOC | V4.0 | 2009.06

4

en | Table of Contents

6

6.1

6.2

6.3

6.4

6.5

6.6

6.7

6.8

6.9

7

7.1

7.2

7.3

7.4

5.26

5.27

5.28

5.29

5.30

5.31

5.32

5.33

5.34

5.19

5.20

5.21

5.22

5.23

5.24

5.25

5.40

5.41

5.42

5.43

5.44

5.45

5.46

5.35

5.36

5.37

5.38

5.39

Advanced Mode: Encoder Profile

Advanced Mode: Audio

Advanced Mode: Storage Management

Advanced Mode: Remote Video Device

Advanced Mode: Recording Profiles

Advanced Mode: Retention Time

Advanced Mode: Recording Scheduler

Advanced Mode: Recording Status

Advanced Mode: Alarm Connections

Advanced Mode: VCA

Advanced Mode: VCA Profiles

Advanced Mode: VCA Scheduled

Advanced Mode: VCA Event Triggered

Advanced Mode: Audio Alarm

Advanced Mode: Alarm E-Mail

Advanced Mode: Alarm Task Editor

Advanced Mode: Alarm Inputs

Advanced Mode: Relay

Advanced Mode: COM1

Advanced Mode: Network

Advanced Mode: Advanced

Advanced Mode: Multicasting

Advanced Mode: JPEG Posting

Advanced Mode: Encryption

Advanced Mode: Maintenance

Advanced Mode: Licenses

Advanced Mode: System Overview

Function Test

Operation

Operation with Microsoft Internet Explorer

The LIVEPAGE

Saving Snapshots

Recording Video Sequences

Running Recording Program

The RECORDINGS Page

Installing the Player

Hardware Connections Between Video Servers

Operation Using Software Decoders

Maintenance and Upgrades

Testing the Network Connection

Unit Reset

Repairs

Transfer and Disposal

8

8.1

8.2

Appendix

Troubleshooting

General Malfunctions

DOC | V4.0 | 2009.06

Installation and Operating Manual

VideoJet X10 SN

103

103

104

Bosch Security Systems

95

97

98

100

89

89

91

94

94

94

101

101

101

102

102

66

68

69

70

72

58

58

61

62

46

49

50

52

53

55

56

81

82

83

84

86

86

87

73

73

75

76

79

VideoJet X10 SN

9

9.1

9.2

10

8.3

8.4

8.5

8.6

8.7

8.8

8.9

8.10

11

Malfunctions with iSCSI Connections

LEDs

Processor Load

Network Connection

Serial Interface

Terminal Block

Communication with Terminal Program

Copyrights

Specifications

Unit

Protocols/Standards

Glossary

Index

Table of Contents | en

5

113

113

114

115

106

107

108

108

108

109

110

112

119

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

6

en | Table of Contents VideoJet X10 SN

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

1

1.1

1.2

1.3

i

!

Preface | en

7

Preface

About this Manual

This manual is intended for persons responsible for the installation and operation of the

VideoJet X10 SN. International, national and any regional electrical engineering regulations must be followed at all times. Relevant knowledge of network technology is required. The manual describes the installation and operation of the unit.

Conventions in this Manual

In this manual, the following symbols and notations are used to draw attention to special situations:

CAUTION!

This symbol indicates that failure to follow the safety instructions described may endanger persons and cause damage to the unit or other equipment.

It is associated with immediate, direct hazards.

NOTICE!

This symbol refers to features and indicates tips and information for easier, more convenient use of the unit.

Intended Use

The VideoJet X10 SN network video server transfers video, audio and control signals over data networks (Ethernet LAN, Internet). There are various memory options for recording the images captured by the connected camera. The unit is intended for use with CCTV systems.

Various functions can be triggered automatically by incorporating external alarm sensors.

Other applications are not permitted.

In the event of questions concerning the use of the unit which are not answered in this manual, please contact your sales partner or:

Bosch Security Systems

Robert-Koch-Straße 100

85521 Ottobrunn

Germany www.boschsecurity.com

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

8

en | Preface

1.4

1.5

VideoJet X10 SN

EU Directives

The VideoJet X10 SN network video server complies with the requirements of EU Directives

89/336 (Electromagnetic Compatibility) and 73/23, amended by 93/68 (Low Voltage

Directive).

Rating Plate

For exact identification, the model name and serial number are inscribed on the bottom of the housing. Please make a note of this information before installation, if necessary, so as to have it to hand in case of questions or when ordering spare parts.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

2

2.1

2.2

2.3

Safety Information | en

9

Safety Information

Electric Shock Hazard

– Never attempt to connect the unit to any power network other than the type for which it is intended.

– Use only power supply units with UL approval and a power output according to LPS or

NEC Class 2.

– Never open the housing.

– Never open the housing of the power supply unit.

– If a fault occurs, disconnect the power supply unit from the power supply and from all other units.

– Install the power supply and the unit only in a dry, weather-protected location.

– If safe operation of the unit cannot be ensured, remove it from service and secure it to prevent unauthorized operation. In such cases, have the unit checked by Bosch Security

Systems.

Safe operation is no longer possible in the following cases:

– if there is visible damage to the unit or power cables,

– if the unit no longer operates correctly,

– if the unit has been exposed to rain or moisture,

– if foreign bodies have penetrated the unit,

– after long storage under adverse conditions, or

– after exposure to extreme stress in transit.

Installation and Operation

– The relevant electrical engineering regulations and guidelines must be complied with at all times during installation.

– Relevant knowledge of network technology is required to install the unit.

– Before installing or operating the unit, make sure you have read and understood the documentation for the other equipment connected to it, such as cameras. The documentation contains important safety instructions and information about permitted uses.

– Perform only the installation and operation steps described in this manual. Any other actions may lead to personal injury, damage to property or damage to the equipment.

Maintenance and Repair

– Never open the housing of the VideoJet X10 SN. The unit does not contain any userserviceable parts.

– Never open the housing of the power supply unit. The power supply unit does not contain any user-serviceable parts.

– Ensure that all maintenance or repair work is carried out only by qualified personnel

(electrical engineers or network technology specialists).

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

10

en | Safety Information VideoJet X10 SN

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

3

3.1

i

Product Description | en

11

Product Description

Scope of Delivery

– VideoJet X10 SN network video server

– 4 terminal blocks

– Quick Installation Guide

– Product CD with the following content:

– Quick Installation Guide

– Manual

– System Requirements document

– Further documentation on Bosch Security Systems products

– Configuration Manager

– MPEG ActiveX control

– Player and Archive Player

– DirectX control

– Microsoft Internet Explorer

– Sun JVM

– Adobe Acrobat Reader

NOTICE!

Check that the delivery is complete and in perfect condition. Arrange for the unit to be checked by Bosch Security Systems if you find any damage.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

12

en | Product Description

3.2

i

VideoJet X10 SN

System Requirements

General Requirements

– Computer with Windows XP or Windows Vista operating system

– Network access (Intranet or Internet)

– Screen resolution 1,024 × 768 pixels

– 16- or 32-bit color depth

– Installed Sun JVM

NOTICE!

Also note the information in the System Requirements document on the product CD supplied. If necessary, you can install the required programs and controls from the product

CD supplied (see Section 3.1 Scope of Delivery, page 11).

The Web browser must be configured to enable Cookies to be set from the IP address of the unit.

In Windows Vista, deactivate protected mode on the Security tab under Internet Options.

You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer.

Additional Configuration Requirements

– Microsoft Internet Explorer (version 6.0 or higher) or

– Installed Configuration Manager program (version 2.0 or higher)

Additional Operational Requirements

– Microsoft Internet Explorer (version 6.0 or higher) or

– Receiver software, for example VIDOS (version 3.11 or higher) or Bosch Video

Management System (version 2.02 or higher) or

– MPEG-4 compatible hardware decoder from Bosch Security Systems (for example

VIP XD) as a receiver and connected video monitor

– For playing back recordings: connection to storage medium

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

3.3

Product Description | en

13

Overview of Functions

Network Video Server

The VideoJet X10 SN is a compact network video server for a connected video source. It is primarily designed for encoding video, audio and control data for transfer over an IP network.

With its encoding in the MPEG-4 format, the VideoJet X10 SN is ideally suited for making existing analog CCTV cameras IP-compatible and for remote access to digital VCRs and multiplexers.

The use of existing networks means that integration with CCTV systems or local networks can be achieved quickly and easily.

Two units, for example a VideoJet X10 SN as a sender and a VIP XD as a receiver, can create a standalone system for data transfer without a PC. Video images from a single sender can be received simultaneously on multiple receivers. Audio signals can also be transmitted from and to compatible units.

Receiver

Compatible MPEG-4 enabled hardware decoders (for example the VIP XD) can be used as receivers. Computers with decoding software such as VIDOS or computers with the Microsoft

Internet Explorer Web browser can also be used as receivers.

Video Encoding

The VideoJet X10 SN uses the MPEG-4 and H.264 video compression standards. Thanks to efficient encoding, the data rate remains low even with high image quality and can also be adapted to local conditions within wide limits.

Dual Streaming

Dual Streaming allows the incoming data stream to be encoded simultaneously according to two different, individually customized profiles. This feature creates two data streams that can serve different purposes, for example one for recording and one optimized for live transmission over the LAN.

Multicast

In suitably configured networks, the multicast function enables simultaneous real-time video transmission to multiple receivers. The UDP and IGMP V2 protocols must be implemented on the network for this function.

Encryption

The VideoJet X10 SN offers a variety of options for protection against unauthorized reading.

Web browser connections can be protected using HTTPS. You can protect the control channels via the SSL encryption protocol. With an additional license, the user data itself can be encrypted.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

14

en | Product Description VideoJet X10 SN

Remote Control

For remote control of external units such as pan or tilt heads for cameras or motorized zoom lenses, control data is transmitted via the VideoJet X10 SN's bidirectional serial interface. This interface can also be used to transmit transparent data.

Tamper Detection and Motion Detectors

The VideoJet X10 SN offers a wide range of configuration options for alarm signaling in the event of tampering with the connected camera. An algorithm for detecting movement in the video image is also part of the scope of delivery and can optionally be extended to include special video analysis algorithms.

Snapshots

Individual video frames (snapshots) can be called up as JPEG images by the VideoJet X10 SN, stored on the computer's hard drive or displayed in a separate browser window.

Recordings

Various local memory options enable the VideoJet X10 SN to be used as a digital VCR. The

VideoJet X10 SN supports ANR technology, which guarantees seamless recording without gaps via VIDOS-NVR, even during network failures. A connection to an appropriately configured iSCSI system enables long-term recordings with high image quality over the network.

Backup

A function for storing the video images displayed on the hard drive of your computer is available on the LIVEPAGE as well as on the RECORDINGS page. Video sequences can be stored by means of a mouse click and can be redisplayed using the Player supplied as part of the scope of delivery.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Product Description | en

15

Summary

The VideoJet X10 SN provides the following main functions:

– Video and data transmission over IP data networks

– Dual Streaming function for the encoder for simultaneous encoding with two individually definable profiles

– Multicast function for simultaneous image transmission to multiple receivers

– One analog BNC composite video input (PAL/NTSC)

– Video encoding to international standard MPEG-4

– Integrated Ethernet port (10/100 Base-T)

– CF slot for CompactFlash cards for local storage

– USB interfaces for future WAN or WLAN connections

– Transparent, bidirectional data channel via RS-232/RS-422/RS-485 serial interface

– Configuration and remote control of all internal functions via TCP/IP, also secured via

HTTPS

– Password protection to prevent unauthorized connection or configuration changes

– Extensive, flexible storage options

– Four alarm inputs and four relay outputs

– Built-in video sensor for motion and tamper alarms

– Event-controlled automatic connection

– Convenient maintenance via uploads

– Flexible encryption of control and data channels

– Authentication according to international standard 802.1x

– Transmission and receipt of audio signals

– Bidirectional audio (mono) for line connections

– Audio encoding to international standard G.711

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

16

en | Product Description

3.4

Connections on the Front Panel

VideoJet X10 SN

1

2

3

4

5

6

USB interface

for future expansion of functions

Video In video input

BNC socket for connecting the video source

Audio In audio line input

3.5 mm stereo socket for connecting an audio line input signal

Audio Out audio line output

3.5 mm stereo socket for connecting an audio line output signal

Connect LED

flashes green when the unit is connected to a video

CF LED

flashes orange when activity is detected on the CF card

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

3.5

Connections on the Rear Panel

Product Description | en

17 i

7

8

9

10

11

ETH RJ45 socket

for connecting to an Ethernet LAN (local network), 10/100 MBit Base-T

ETH LED

lights up yellow when the unit is connected to the network via ETH

Terminal block for alarm inputs, relay outputs, serial interface and power supply

Factory reset button to restore factory default settings

Compact Flash slot

for a CF card type I or type II

NOTICE!

For more information about the LEDs, see Section 8.4 LEDs, page 107.

For terminal block assignment, see Section 8.8 Terminal Block, page 109.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

18

en | Product Description VideoJet X10 SN

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

4

4.1

4.2

!

Installation | en

19

Installation

Preparations

CAUTION!

The unit is intended for use indoors or in housings.

Select a suitable location for installation that guarantees to meet the environmental conditions. The ambient temperature must be between 0 and +50 °C (+32 and +122 °F). The relative humidity must not exceed 95%.

The VideoJet X10 SN generates heat during operation, so you should ensure that there is adequate ventilation and enough clearance between the unit and heat-sensitive objects or equipment.

Please ensure the following installation conditions:

– Do not install the unit close to heaters or other heat sources. Avoid locations exposed to direct sunlight.

– Allow sufficient space for running cables.

– Ensure that the unit has adequate ventilation.

– When making connections, use only the cables supplied or use appropriate cables immune to electromagnetic interference.

– Position and run all cables so that they are protected from damage, and provide adequate cable strain relief where needed.

– Avoid impacts, blows and severe vibrations that exceed the specification limits (see

Section 9 Specifications, page 113), as these can irreparably damage the unit.

Mounting

You can purchase a rack-mount kit from Bosch Security Systems, which is designed to accommodate three VideoJet X10 SN.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

20

en | Installation

4.3

i

VideoJet X10 SN

Connections

Camera

You can connect a video source to the VideoJet X10 SN. Any cameras and other video sources that produce a standard PAL or NTSC signal are suitable.

1.

Connect the camera or another video source to the BNC Video In socket using a video cable (75 Ohm, BNC plug).

2.

If the video signal is not looped through, termination is performed by a software setting if

necessary (see Section 5.17 Advanced Mode: Video Input, page 44).

Audio Connections

The VideoJet X10 SN has two audio ports for audio line signals.

The audio signals are transmitted two-way and in sync with the video signals. As a result, you can connect a speaker or door intercom system at the destination point, for example. The following specifications should be complied with in all cases.

1 × Line In:

1 × Line Out:

Impedance 9 kOhm typ., 5.5 V p-p

max. input voltage

Impedance 10 kOhm typ., 3.0 V p-p

max. output voltage, impedance 16 Ohm min., 1.7 V p-p

max. output voltage

The stereo plugs must be connected as follows:

Contact

Tip

Middle ring

Lower ring

Line In function

Channel 1

Ground

Line Out function

Channel 1

Ground

1.

Connect an audio source with line level to the Audio In socket of the VideoJet X10 SN with a 3.5 mm stereo plug.

2.

Connect a unit with line-in connection to the Audio Out socket of the VideoJet X10 SN with a 3.5 mm stereo plug.

Network

You can connect the VideoJet X10 SN to a 10/100 Base-T network using a standard UTP category 5 cable with RJ45 plugs.

X

Connect the VideoJet X10 SN to the network via the ETH socket.

CF Slot

You can insert a type I or II CompactFlash card into the Compact Flash slot to enable recordings to be saved locally. CF cards are the ideal solution for shorter storage times and temporary recordings, for example alarm recordings or local buffering in the event of network interruptions.

NOTICE!

You can obtain a list of compatible CF cards from your supplier or directly from Bosch

Security Systems. This list is constantly being updated and extended.

Playing back recordings is also possible using a different VideoJet X10, a VideoJet X20 or a

VideoJet X40.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

i

!

!

Installation | en

21

CAUTION!

If the card is formatted, all existing data is deleted from the card.

You should therefore check whether the CF card contains any data that needs to be backed up before it is inserted.

1.

Carefully slide the CF card, top side down, into the slot as far as it will go.

2.

To remove the CF card, simply pull it out.

Data Interface

The bidirectional data interface is used to control units connected to the VideoJet X10 SN, such as a dome camera with a motorized lens. The connection supports the RS-232, RS-422 and RS-485 transmission standards.

The VideoJet X10 SN offers the serial interface via the orange terminal block (see

Section 8.8 Terminal Block, page 109).

The range of controllable equipment is expanding constantly. The manufacturers of the relevant equipment provide specific information on installation and control.

CAUTION!

Please take note of the appropriate documentation when installing and operating the unit to be controlled.

The documentation contains important safety instructions and information about permitted uses.

NOTICE!

A video connection is necessary to transmit transparent data.

i

Alarm Inputs

The VideoJet X10 SN has four alarm inputs on the orange terminal block (see

Section 8.8 Terminal Block, page 109). The alarm inputs are used to connect to external alarm

devices such as door contacts or sensors. With the appropriate configuration, an alarm sensor can automatically connect the VideoJet X10 SN to a remote location, for example.

A zero potential closing contact or switch can be used as the actuator.

NOTICE!

If possible, use a bounce-free contact system as the actuator.

X

Connect the lines to the appropriate terminals on the orange terminal block (IN1 to IN4) and check that the connection is secure.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

22

en | Installation

!

VideoJet X10 SN

Relay Outputs

The VideoJet X10 SN has four relay outputs for switching external units such as lamps or alarm sirens. You can operate these relay outputs manually while there is an active connection to the VideoJet X10 SN. The outputs can also be configured to automatically activate sirens or other alarm units in response to an alarm signal. The relay outputs are also located on the

orange terminal block (see Section 8.8 Terminal Block, page 109).

CAUTION!

A maximum load of 30 V and 2 A (SELV) may be applied to the relay contacts.

X

Connect the lines to the appropriate terminals on the orange terminal block (R1 to R4) and check that the connection is secure.

Remote Indication of the Connection Status

When the VideoJet X10 SN is connected to a video, the Connect LED on the front panel of the unit flashes. The LED also provides information on the operational state of the unit and signals

a unit defect (see Section 8.4 LEDs, page 107).

You can connect an additional two-color LED to the VideoJet X10 SN as a remote indicator.

This provides the same information as the integrated Connect LED. A remote indicator can be useful if the VideoJet X10 SN is installed at a location that is difficult to access or see, for example in a cable duct or on top of a mast. Just like the integrated LED, the remote indicator

LED should also light up red and green in order to avoid confusion.

Please comply with the following specifications and the connection diagram:

Voltage between RM1 and RM2

Current between RM1 and RM2

Source resistance

3.3 V DC max.

25 mA max.

140 Ohm typ.

1.

Connect the LED lines to the appropriate terminals on the orange terminal block (RM1 and RM2) and check that the connection is secure.

2.

Check that the signals on the Connect LED on the VideoJet X10 SN and the remote indicator LED correspond.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

i

!

Installation | en

23

Backup Power Supply

If the VideoJet X10 SN does not have a permanent power supply, it may be necessary to supply the internal clock separately. To do this, you can connect the VideoJet X10 SN directly to a battery via the BP and GND contacts. The correct time is crucial for evaluating local recordings.

CAUTION!

Connect only batteries with the following specification: 10 to 30 V DC, 50 Ah max.,

12/24 V continuous flow.

1.

Connect the + (plus) line on the battery to the BP terminal on the orange terminal block.

2.

Connect the (minus) line on the battery to the GND terminal on the orange terminal block.

3.

Now check that the connections are secure.

NOTICE!

If you do not connect a battery to the unit, you should specify a time server to ensure correct system time.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

24

en | Installation

4.4

4.5

i

!

VideoJet X10 SN

Power On/Power Off

Power Supply

The VideoJet X10 SN does not have a power switch. Power is supplied via a separate unit.

Connect the VideoJet X10 SN to the power supply unit and plug this into the mains. The unit is now ready for use. The VideoJet X10 SN does not come supplied with a power supply unit.

CAUTION!

Use only power supply units with UL approval and a power output according to LPS or

NEC Class 2.

Where necessary, use suitable equipment to ensure that the power supply is free from interference such as voltage surges, spikes or voltage drops.

Do not connect the VideoJet X10 SN to the power supply until all other connections have been made.

1.

Plug the terminal block with the PSU cable connected to it into the orange socket on the

VideoJet X10 SN.

2.

Connect the power supply unit to the mains. The VideoJet X10 SN is ready for use as soon as the Connect LED changes from a red light, indicating the start-up procedure, to a green light.

Provided the network connection has been correctly made, the yellow ETH LED also lights up.

A flashing ETH LED signals that data packets are being transmitted via the network.

Setup Using the Configuration Manager

The Configuration Manager program can be found on the product CD contained in the scope of delivery. This program allows you to implement and set up new video servers in the network quickly and conveniently.

NOTICE!

Using the Configuration Manager to set all parameters in the VideoJet X10 SN is an alternative to configuration by means of a Web browser, as described in chapter 5 of this manual.

Installing the Program

1.

Insert the CD into the computer's CD-ROM drive.

2.

If the CD does not start automatically, open the Configuration Manager directory using

Windows Explorer and double-click Setup.exe.

3.

Follow the on-screen instructions.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Installation | en

25

Configuring the VideoJet X10 SN

You can start the Configuration Manager immediately after installation.

1.

Double-click the icon on the desktop or start the program via the Start menu. After the program has started, the network is immediately searched for compatible video servers.

i

2.

You can start the configuration if a VideoJet X10 SN is shown in the list in the left section of the window. To do this, right-click the entry for the unit.

3.

Click Unit network settings... in the popup menu.

4.

In the Unit IP address field, enter a valid IP address for your network (for example

192.168.0.110) and click OK. The unit reboots and the IP address is valid.

5.

If required, enter an appropriate subnet mask for the IP address, and additional network data.

NOTICE!

You must reboot to activate the new IP address, a new subnet mask or a gateway IP address.

Reboot

You can trigger the reboot directly with the assistance of the Configuration Manager.

X

Right-click the entry for the unit in the list in the left section of the window and select the

Reset command from the context menu.

Additional Parameters

You can check and set additional parameters with the assistance of the Configuration

Manager. You can find detailed information on this in the documentation for this program.

DOC | V4.0 | 2009.06

Bosch Security Systems Installation and Operating Manual

26

en | Installation VideoJet X10 SN

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5

5.1

i

Configuration Using a Web Browser | en

27

Configuration Using a Web Browser

Connecting

The integrated HTTP server in the VideoJet X10 SN provides you with the option to configure the unit over the network with a Web browser. This option is an alternative to configuration using the Configuration Manager program and is considerably richer in function and more convenient than configuration using the terminal program.

System Requirements

– Computer with Windows XP or Windows Vista operating system

– Network access (Intranet or Internet)

– Microsoft Internet Explorer (version 6.0 or higher)

– Screen resolution 1,024 × 768 pixels

– 16- or 32-bit color depth

– Installed Sun JVM

NOTICE!

Also note the information in the System Requirements document on the product CD supplied. If necessary, you can install the required programs and controls from the product

CD supplied (see Section 3.1 Scope of Delivery, page 11).

The Web browser must be configured to enable Cookies to be set from the IP address of the unit.

In Windows Vista, deactivate protected mode on the Security tab under Internet Options.

You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer.

Installing MPEG ActiveX

Suitable MPEG ActiveX software must be installed on the computer to allow the live video images to be played back. If necessary, you can install the program from the product CD supplied.

1.

Insert the product CD into the computer's CD-ROM drive. If the CD does not start automatically, open the root directory of the CD in Windows Explorer and double-click

MPEGAx.exe.

2.

Follow the on-screen instructions.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

28

en | Configuration Using a Web Browser VideoJet X10 SN

Establishing the Connection

Before you can operate the VideoJet X10 SN within your network, it must have a valid IP address for your network and a compatible subnet mask.

The following default address is preset at the factory: 192.168.0.1

1.

Start the Web browser.

2.

Enter the IP address of the VideoJet X10 SN as the URL. The connection is established and after a short time you will see the LIVEPAGE with the video image.

Maximum Number of Connections

If you do not connect, the unit may have reached its maximum number of connections.

Depending on the unit and network configuration, each VideoJet X10 SN can have up to 25

Web browser connections or up to 50 connections via VIDOS or Bosch Video Management

System.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.2

i

!

Configuration Using a Web Browser | en

29

Protected VideoJet X10 SN

If the VideoJet X10 SN is password protected against unauthorized access, the Web browser displays a corresponding message and prompts you to enter the password when you attempt to access protected areas.

NOTICE!

The VideoJet X10 SN offers the option to limit the extent of access using various authorization

levels (see Section 5.11 Advanced Mode: Password, page 38).

1.

Enter the user name and associated password in the corresponding text fields.

2.

Click OK. If the password is entered correctly, the Web browser displays the page that was called up.

Protected Network

If a RADIUS server is employed in the network for managing access rights (802.1x authentication), the VideoJet X10 SN must be configured accordingly, otherwise no communication is possible.

To configure the unit, you must connect the VideoJet X10 SN directly to a computer using a network cable. This is because communication via the network is not enabled until the

Identity and Password parameters have been set and successfully authenticated (see

Section Authentication, page 80).

Configuration Menu

The SETTINGS page provides access to the configuration menu, which contains all the unit's parameters arranged in groups. You can view the current settings by opening one of the configuration screens. You can change the settings by entering new values or by selecting a predefined value from a list field.

There are two options for configuring the unit or checking the current settings:

– Basic mode

– Advanced mode

In Basic Mode the most important parameters are arranged in seven groups. This allows you to change the basic settings with just a few entries and then put the device into operation.

Advanced Mode is recommended for expert users or system support personnel. You can

access all unit parameters in this mode. Settings that affect the fundamental functionality of the unit (such as firmware updates) can only be altered in the advanced mode.

All parameter groups are described in this chapter in the order in which they are listed in the configuration menu, from the top of the screen to the bottom.

CAUTION!

The settings in the advanced mode should only be processed or modified by expert users or system support personnel.

All settings are backed up in the VideoJet X10 SN memory so they are not lost even if the power fails.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

30

en | Configuration Using a Web Browser VideoJet X10 SN

Starting Configuration

X

Click the SETTINGS link in the upper section of the window. The Web browser opens a new page with the configuration menu.

!

Navigation

1.

Click one of the menu items in the left window margin. The corresponding submenu is displayed.

2.

Click one of the entries in the submenu. The Web browser opens the corresponding page.

Making Changes

Each configuration screen shows the current settings. You can change the settings by entering new values or by selecting a predefined value from a list field.

X

After each change, click Set to save the change.

CAUTION!

Save each change with the associated Set button.

Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.3

Basic Mode: Unit Access

Configuration Using a Web Browser | en

31

!

!

Bosch Security Systems

Device name

You can give the VideoJet X10 SN a name to make it easier to identify. The name makes the task of administering multiple units in larger video monitoring systems easier, for example using the VIDOS or Bosch Video Management System programs.

The device name is used for the remote identification of a unit, in the event of an alarm for example. For this reason, enter a name that makes it as easy as possible to quickly identify the location.

CAUTION!

Do not use any special characters, for example &, in the name.

Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player being unable to play back the recording.

Camera 1

The camera name makes it easier to identify the remote camera location, in the event of an alarm for example. It will be displayed in the video screen if configured to do so (see

Section Camera name stamping, page 40). The camera name makes the task of administering

cameras in larger video monitoring systems easier, for example using the VIDOS or Bosch

Video Management System programs.

Enter a unique, unambiguous name for the camera in this field.

CAUTION!

Do not use any special characters, for example &, in the name.

Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player being unable to play back the recording.

Password

A VideoJet X10 SN is generally protected by a password to prevent unauthorized access to the unit. You can use different authorization levels to limit access.

The VideoJet X10 SN operates with three authorization levels: service, user and live.

Installation and Operating Manual DOC | V4.0 | 2009.06

32

en | Configuration Using a Web Browser

5.4

i i

VideoJet X10 SN

The highest authorization level is service. After entering the correct password, you can access all the functions of the VideoJet X10 SN and change all configuration settings.

With the user authorization level, you can operate the unit and also control cameras, for example, but you cannot change the configuration.

The lowest authorization level is live. It can only be used to view the live video image and switch between the different live image displays.

You can define and change a password for each authorization level if you are logged in as

service or if the unit is not password protected.

Enter the password for the appropriate authorization level here.

NOTICE!

Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. If a live password is assigned, for example, a service and a user password must also be set. When assigning passwords, you should therefore always start from the highest authorization level, service, and use different passwords.

Confirm password

In each case, enter the new password a second time to eliminate typing mistakes.

NOTICE!

A new password is only saved when you click the Set button. You should therefore click the

Set button immediately after entering and confirming a password.

Basic Mode: Date/Time

DOC | V4.0 | 2009.06

Unit date/Unit time/Unit time zone

If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time. If necessary, you can synchronize the unit with your computer's system settings.

X

Click the Sync to PC button to copy your computer's system time to the

VideoJet X10 SN.

Time server IP address

The VideoJet X10 SN can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The unit polls the time signal automatically once every minute.

X

Enter the IP address of a time server here.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.5

Configuration Using a Web Browser | en

33

Time server type

Select the protocol that is supported by the selected time server. Preferably, you should select the SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions.

Select Time server for a time server that works with the protocol RFC 868.

Basic Mode: Network

!

The settings on this page are used to integrate the VideoJet X10 SN into an existing network.

Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.

1.

Make the desired changes.

2.

Click the Set and Reboot button. The VideoJet X10 SN is rebooted and the changed settings are activated.

CAUTION!

If you change the IP address, subnet mask or gateway address, the VideoJet X10 SN is only available under the new addresses after the reboot.

DHCP

If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you can activate acceptance of IP addresses automatically assigned to the VideoJet X10 SN.

Certain applications (VIDOS, Bosch Video Management System, Archive Player, Configuration

Manager) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server must support the fixed assignment between IP address and

MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted.

IP address

Enter the desired IP address for the VideoJet X10 SN in this field. The IP address must be valid for the network.

Subnet mask

Enter the appropriate subnet mask for the selected IP address here.

Gateway address

If you want the unit to establish a connection to a remote location in a different subnet, enter the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

34

en | Configuration Using a Web Browser

5.6

Basic Mode: Encoder Profile

VideoJet X10 SN

Active profile

You can select a profile for encoding the video signal.

You can use this to adapt the video data transmission to the operating environment (for example network structure, bandwidth, data load).

Pre-programmed profiles are available, each giving priority to different perspectives. When selecting a profile, details are displayed in the list field.

Low bandwidth (CIF)

High quality for low bandwidth connections, resolution 352 × 288/240 pixels

Low delay (2/3 D1)

High quality with low delay, resolution 464 × 576/480 pixels

High resolution (4CIF/D1)

High resolution for high bandwidth connections, resolution 704 × 576/480 pixels

DSL

For DSL connections with 500 kbps, resolution 352 × 288/240 pixels

ISDN (2B)

For ISDN connections via two B-channels, resolution 352 × 288/240 pixels

ISDN (1B)

For ISDN connections via one B-channel, resolution 352 × 288/240 pixels

Modem

For analog modem connections with 20 kbps, resolution 352 × 288/240 pixels

GSM

For GSM connections at 9,600 baud, resolution 176 × 144/120 pixels

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.7

Basic Mode: Audio

Configuration Using a Web Browser | en

35

5.8

You can set the gain of the audio signals to suit your specific requirements. The current video image is shown in the small window next to the slide controls to help you check the audio source and improve assignments. Your changes are effective immediately.

If you connect via Web browser, you must activate the audio transmission on the LIVEPAGE

Functions page (see Section 5.15 Advanced Mode: LIVEPAGE Functions, page 42). For other

connections, the transmission depends on the audio settings of the respective system.

Audio

The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data are encoded according to G.711 and require an additional bandwidth of approx. 80 kbps for each connection. If you do not want any audio data to be transmitted, select Off.

Line In 1

You can set the line input gain. Make sure that the display does not go beyond the green zone during modulation.

Line Out

You can set the line output gain. Make sure that the display does not go beyond the green zone during modulation.

Basic Mode: Recording

Bosch Security Systems

You can record the images from the camera connected to the VideoJet X10 SN on various local storage media or on an appropriately configured iSCSI system.

CF cards (see Section CF Slot, page 20) are the ideal solution for shorter storage times.

if the VideoJet X10 SN has a USB hard drive, this is suitable for longer, local recordings.

For long-term, authoritative images, it is essential that you use an appropriately sized iSCSI system.

Here you can select a storage medium and immediately start or stop the recording.

Storage medium

1.

Select the required storage medium from the list.

2.

Click the Start button to start the recording immediately.

Installation and Operating Manual DOC | V4.0 | 2009.06

36

en | Configuration Using a Web Browser

5.9

Basic Mode: System Overview

VideoJet X10 SN

5.10

i

The data on this page are for information purposes only and cannot be changed. Keep a record of this information in case technical assistance is required.

NOTICE!

You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail.

Advanced Mode: Identification

DOC | V4.0 | 2009.06

Device ID

Each VideoJet X10 SN should be assigned a unique identifier that you can enter here as an additional means of identification.

Device name

You can give the VideoJet X10 SN a name to make it easier to identify. The name makes the task of administering multiple units in larger video monitoring systems easier, for example using the VIDOS or Bosch Video Management System programs.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

!

!

Configuration Using a Web Browser | en

37

The device name is used for the remote identification of a unit, in the event of an alarm for example. For this reason, enter a name that makes it as easy as possible to quickly identify the location.

CAUTION!

Do not use any special characters, for example &, in the name.

Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player being unable to play back the recording.

Camera 1

The camera name makes it easier to identify the remote camera location, in the event of an alarm for example. It will be displayed in the video screen if configured to do so (see

Section Camera name stamping, page 40). The camera name makes the task of administering

cameras in larger video monitoring systems easier, for example using the VIDOS or Bosch

Video Management System programs.

Enter a unique, unambiguous name for the camera in this field. You can use both lines for this.

CAUTION!

Do not use any special characters, for example &, in the name.

Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player being unable to play back the recording.

You can use the second line for entering additional characters; these can be selected from a table.

1.

Click the icon next to the second line. A new window with the character map is opened.

2.

Click the required character. The character is inserted into the Result field.

3.

In the character map, click the << and >> icons to move between the different pages of the table, or select a page from the list field.

4.

Click the < icon to the right of the Result field to delete the last character, or click the X icon to delete all characters.

5.

Now click the OK button to apply the selected characters to the second line of the

Camera 1 parameters. The window will close.

Initiator extension

You can attach your own text to the initiator name of the VideoJet X10 SN to make the unit easier to identify in large iSCSI systems. This text is added to the initiator name, separated from it by a full stop. You can see the initiator name in the system overview (see

Section 5.9 Basic Mode: System Overview, page 36).

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

38

en | Configuration Using a Web Browser

5.11

Advanced Mode: Password

VideoJet X10 SN

i i

A VideoJet X10 SN is generally protected by a password to prevent unauthorized access to the unit. You can use different authorization levels to limit access.

NOTICE!

Proper password protection is only guaranteed when all higher authorization levels are also protected with a password. If a live password is assigned, for example, a service and a user password must also be set. When assigning passwords, you should therefore always start from the highest authorization level, service, and use different passwords.

Password

The VideoJet X10 SN operates with three authorization levels: service, user and live.

The highest authorization level is service. After entering the correct password, you can access all the functions of the VideoJet X10 SN and change all configuration settings.

With the user authorization level, you can operate the unit and also control cameras, for example, but you cannot change the configuration.

The lowest authorization level is live. It can only be used to view the live video image and switch between the different live image displays.

You can define and change a password for each authorization level if you are logged in as

service or if the unit is not password protected.

Enter the password for the appropriate authorization level here.

Confirm password

In each case, enter the new password a second time to eliminate typing mistakes.

NOTICE!

A new password is only saved when you click the Set button. You should therefore click the

Set button immediately after entering and confirming a password.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.12

Advanced Mode: Date/Time

Configuration Using a Web Browser | en

39 i

Bosch Security Systems

Date format

Select your required date format.

Unit date/Unit time

If there are multiple devices operating in your system or network, it is important to synchronize their internal clocks. For example, it is only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time.

1.

Enter the current date. Since the unit time is controlled by the internal clock, there is no need to enter the day of the week – it is added automatically.

2.

Enter the current time or click the Sync to PC button to copy your computer's system time to the VideoJet X10 SN.

Unit time zone

Select the time zone in which your system is located.

Daylight saving time

The internal clock can switch automatically between normal and daylight saving time (DST).

The unit already contains the data for DST switch-overs up to the year 2018. You can use these data or create alternative time saving data if required.

NOTICE!

If you do not create a table, there will be no automatic switching. When changing and clearing individual entries, remember that two entries are usually related to each other and dependent on one another (switching to summer time and back to normal time).

1.

First check whether the correct time zone is selected. If it is not correct, select the appropriate time zone for the system, and click the Set button.

2.

Click the Details button. A new window will open and you will see the empty table.

3.

Select the region or the city that is closest to the system's location from the list field below the table.

4.

Click the Generate button to generate data and enter it into the table.

5.

Make changes by clicking an entry in the table. The entry is selected.

6.

Clicking the Delete button will remove the entry from the table.

7.

Select other values from the list fields below the table to change the entry. Changes are made immediately.

Installation and Operating Manual DOC | V4.0 | 2009.06

40

en | Configuration Using a Web Browser

5.13

VideoJet X10 SN

8.

If there are empty lines at the bottom of the table, for example after deletions, you can add new data by marking the row and selecting required values from the list fields.

9.

Now click the OK button to save and activate the table.

Time server IP address

The VideoJet X10 SN can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The unit polls the time signal automatically once every minute.

Enter the IP address of a time server here.

Time server type

Select the protocol that is supported by the selected time server. Preferably, you should select the SNTP server as the protocol. This supports a high level of accuracy and is required for special applications and subsequent function extensions.

Select Time server for a time server that works with the protocol RFC 868.

Advanced Mode: Display Stamping

DOC | V4.0 | 2009.06

Various overlays or "stamps" in the video image provide important supplementary information.

These overlays can be enabled individually and are arranged on the image in a clear manner.

Camera name stamping

This field sets the position of the camera name overlay. It can be displayed at the Top, at the

Bottom or at a position of your choice that you can then specify using the Custom option. Or

it can be set to Off for no overlay information.

1.

Select the desired option from the list.

2.

If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).

3.

In the Position (XY) fields, enter the values for the desired position.

Time stamping

This field sets the position of the time overlay. It can be displayed at the Top, at the Bottom or at a position of your choice that you can then specify using the Custom option. Or it can be set to Off for no overlay information.

1.

Select the desired option from the list.

2.

If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).

3.

In the Position (XY) fields, enter the values for the desired position.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.14

Configuration Using a Web Browser | en

41

Display milliseconds

If necessary, you can also display milliseconds. This information can be useful for recorded video images; however, it does increase the processor's computing time. Select Off if you do not need to display milliseconds.

Alarm mode stamping

Select On to display a text message overlay in the event of an alarm. It can be displayed at a position of your choice that you can then specify using the Custom option. Or it can be set to

Off for no overlay information.

1.

Select the desired option from the list.

2.

If you select the Custom option, additional fields are displayed where you can specify the exact position (Position (XY)).

3.

In the Position (XY) fields, enter the values for the desired position.

Alarm message

Enter the message to be displayed in the event of an alarm. The maximum text length is 31 characters.

Video watermarking

Choose On if you wish the transmitted video images to be "watermarked". After activation, all images are marked with a green W. A red W indicates that the sequence (live or saved) has been manipulated.

Advanced Mode: Appearance

i

Bosch Security Systems

On this page you can adapt the appearance of the web interface and change the website language to meet your requirements. If necessary, you can replace the manufacturer's logo

(top right) and the product name (top left) in the top part of the window with individual graphics.

NOTICE!

You can use either GIF or JPEG images. The file paths must correspond to the access mode

(for example C:\Images\Logo.gif for access to local files, or http://www.mycompany.com/

images/logo.gif for access via the Internet/Intranet).

When accessing via the Internet/Intranet, ensure that a connection is always available to display the image. The image file is not stored in the VideoJet X10 SN.

Website language

Select the language for the user interface here.

Installation and Operating Manual DOC | V4.0 | 2009.06

42

en | Configuration Using a Web Browser

5.15

i i

VideoJet X10 SN

NOTICE!

There are always two languages to choose from: English and another language. If the language you require is not available for selection, you can download the current firmware with another language combination from the website www.boschsecurity.com.

Company logo

Enter the path to a suitable graphic if you want to replace the manufacturer's logo. The image file can be stored on a local computer, in the local network or at an Internet address.

Device logo

Enter the path to a suitable graphic if you want to replace the product name. The image file can be stored on a local computer, in the local network or at an Internet address.

NOTICE!

If you want to use the original graphics again, simply delete the entries in the Company logo and Device logo fields.

JPEG size

You can choose between two given image sizes to display the M-JPEG image on the

LIVEPAGE.

JPEG interval

You can specify the interval at which the individual images should be generated for the M-

JPEG image on the LIVEPAGE.

JPEG quality

You can specify the image quality for displaying M-JPEG on the LIVEPAGE.

Advanced Mode: LIVEPAGE Functions

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

Bosch Security Systems

Configuration Using a Web Browser | en

43

On this page you can adapt the LIVEPAGE functions to your requirements. You can choose from a variety of different options for displaying information and controls.

1.

Check the box for the items that are to be made available on the LIVEPAGE. The selected items are indicated by a check mark.

2.

Check whether the required functions are available on the LIVEPAGE.

Transmit audio

The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data are encoded according to G.711 and require an additional bandwidth of approx. 80 kbps for each connection.

Bilinx control

Next to the field for view control at the top left of the LIVEPAGE, an additional field is displayed for the special Bosch Security Systems Bilinx control.

Lease time (s)

The lease time in seconds determines the time beyond which a different user is authorized to control the camera after no further control signals are received from the current user. After this time interval, the camera is automatically enabled.

Show alarm inputs

Alarm inputs are shown next to the video image as icons, along with their assigned names. If an alarm is active, the corresponding icon changes color.

Show relay outputs

Relay outputs are shown next to the video image as icons, along with their assigned names. If the relay is switched, the icon changes color.

Show VCA trajectories

The trajectories (motion lines of objects) from the video content analysis are displayed in the

live video image if a corresponding analysis type is activated (see Section 5.31 Advanced Mode:

VCA Event Triggered, page 68).

Show VCA metadata

When the analysis function is activated, the additional information from the video content

analysis (VCA) will be displayed in the live video image (see Section 5.31 Advanced Mode: VCA

Event Triggered, page 68). With the MOTION+ analysis type, for example, the sensor fields in

which motion is recorded will be marked with rectangles.

Show event log

The event messages are displayed along with the date and time in a field next to the video image.

Show system log

The system messages are displayed along with the date and time in a field next to the video image and provide information about establishing and ending connections, for example.

Allow snapshots

Here you can specify whether the icon for saving individual images should be displayed below the live image. Individual images can only be saved if this icon is visible.

Allow local recording

Here you can specify whether the icon for saving video sequences on the local memory should be displayed below the live image. Video sequences can only be saved if this icon is visible.

Installation and Operating Manual DOC | V4.0 | 2009.06

44

en | Configuration Using a Web Browser

5.16

VideoJet X10 SN

Path for JPEG and MPEG files

1.

Enter the path for the storage location of individual images and video sequences that you can save from the LIVEPAGE.

2.

If necessary, click Browse to find a suitable directory.

Advanced Mode: Logging

5.17

Save event log

Check this option to save event messages in a text file on your local computer.

You can then view, edit and print this file with any text editor or the standard Office software.

File for event log

1.

Enter the path for saving the event log here.

2.

If necessary, click Browse to find a suitable directory.

Save system log

Check this option to save system messages in a text file on your local computer.

You can then view, edit and print this file with any text editor or the standard Office software.

File for system log

1.

Enter the path for saving the system log here.

2.

If necessary, click Browse to find a suitable directory.

Advanced Mode: Video Input

DOC | V4.0 | 2009.06

You can activate the 75 Ohm terminating resistance for the video input of the

VideoJet X10 SN. The terminating resistance must be deactivated for the video signal to be looped through. Every video input is closed at the time of delivery.

75 Ohm termination input 1

Select Off if the video signal is to be looped through.

Source type input 1

To allow VCRs to be connected as a video source, you can change the characteristic of the video source from the preset value of Camera to VCR. VCRs require a more tolerant setting

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.18

i

Configuration Using a Web Browser | en

45

for the internal PLL as a result of jitter effects caused by the mechanical components of a

VCR.

NOTICE!

In some cases, selecting the VCR option can lead to an improvement in the video image even with a camera connected.

Advanced Mode: Picture Settings

Bosch Security Systems

You can set the video image of the camera to suit your requirements. The current video image is displayed in the small window next to the slide controls as confirmation. Your changes are effective immediately.

1.

Move the slide control to the required position.

2.

Click Default to reset all settings to their default value.

Contrast (0...255)

You can use this function to adapt the contrast of the video image to your working environment.

Saturation (0...255)

You can use this function to adjust the color saturation so as to make the reproduction of colors on your monitor as realistic as possible.

Brightness (0...255)

You can use this function to adapt the brightness of the video image to your working environment.

Low-pass filter (0...255)

You can use this function to filter very fine noise from the image. This reduces and optimizes the bandwidth necessary for image transmission over the network. The image resolution may be impaired.

The higher the value set with the slide control, the flatter the image signal. Check your setting in the image window next to the slide controls.

Also observe the processor load indicator that appears at the top of the window near the

manufacturer's logo (see Section 8.6 Network Connection, page 108).

Installation and Operating Manual DOC | V4.0 | 2009.06

46

en | Configuration Using a Web Browser

5.19

Advanced Mode: Encoder Profile

VideoJet X10 SN

DOC | V4.0 | 2009.06

For the video signal encoding, you can select a code algorithm for each and two profiles, and you can change the presets for the profiles.

You can adapt the video data transmission to the operating environment (for example network structure, bandwidth, data load). To this end, the VideoJet X10 SN simultaneously generates two data streams (Dual Streaming), which compression settings you can select individually, for example one setting for transmissions to the Internet and one for LAN connections.

Pre-programmed profiles are available, each giving priority to different perspectives.

Low bandwidth (CIF)

High quality for low bandwidth connections, resolution 352 × 288/240 pixels

Low delay (2/3 D1)

High quality with low delay, resolution 464 × 576/480 pixels

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

i

!

Configuration Using a Web Browser | en

47

High resolution (4CIF/D1)

High resolution for high bandwidth connections, resolution 704 × 576/480 pixels

DSL

For DSL connections with 500 kbps, resolution 352 × 288/240 pixels

ISDN (2B)

For ISDN connections via two B-channels, resolution 352 × 288/240 pixels

ISDN (1B)

For ISDN connections via one B-channel, resolution 352 × 288/240 pixels

Modem

For analog modem connections with 20 kbps, resolution 352 × 288/240 pixels

GSM

For GSM connections at 9,600 baud, resolution 176 × 144/120 pixels

You can choose between the code algorithms MPEG-4 SH++ and H.264 for each data stream.

H.264 requires a lower bandwidth at the same video quality but it does not offer 4CIF resolution. 4CIF resolution is only possible with MPEG-4 SH++.

1.

Select the required profile for every data stream.

2.

Select the required code algorithm for every data stream.

You can change individual parameter values of a profile and you can also change the name.

You can switch between profiles by clicking the appropriate tabs.

CAUTION!

The profiles are rather complex. They include a large number of parameters that interact with one another, so it is generally best to use the default profiles.

Change the profiles only once you are fully familiar with all the configuration options.

In the default setting, Stream 2 is transmitted for alarm connections and automatic connections. Bear this fact in mind when assigning the profile.

NOTICE!

All parameters combine to make up a profile and are dependent on one another. If you enter a setting that is outside the permitted range for a particular parameter, the nearest permitted value will be substituted when the settings are saved.

Preview for

Select which video data stream should be displayed in the previews. You can deactivate the display of the video images if the performance of the computer is affected too strongly by the decoding of the data streams.

1.

Check the box for the required data stream.

2.

Click the i icon above the relevant preview to display further information about the data stream.

Profile name

You can enter a new name for the profile here. The name is then displayed in the list of available profiles in the Active profile field.

DOC | V4.0 | 2009.06

Bosch Security Systems Installation and Operating Manual

48

en | Configuration Using a Web Browser VideoJet X10 SN

Target data rate

You can limit the data rate for the VideoJet X10 SN to optimize utilization of the bandwidth in your network. The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion.

For complex images or frequent changes of image content due to frequent movements, this limit can be temporarily exceeded up to the value you enter in the Maximum data rate field.

Encoding interval

The figure selected here determines the interval at which images are encoded and transmitted. For example, entering 4 means that only every fourth image is encoded, the following three are skipped - this can be particularly advantageous with low bandwidths. The image rate in ips (images per second) is displayed next to the text field.

Video resolution

Here you can select the desired resolution for the video image. The following resolutions are available:

QCIF

176 × 144/120 pixels

CIF

352 × 288/240 pixels

1/2 D1

352 × 576/480 pixels

2CIF

704 × 288/240 pixels

4CIF/D1

704 × 576/480 pixels

2/3 D1

464 × 576/480 pixels

Default

Click Default to return the profile to the factory default values.

Details

Clicking the Details >> button displays further details on image quality and data transmission.

These settings require extensive knowledge of the MPEG standard and video data compression. Incorrect settings can render the video images unusable.

Maximum data rate

This maximum data rate is not exceeded under any circumstances. Depending on the video quality settings for the I- and P-frames, this fact can result in individual images being skipped.

The value entered here must be at least 10% higher than the value entered in the Target data

rate field. If the value entered here is too low, it will automatically be adjusted.

I-frame distance

This parameter allows you to set the intervals in which the I-frames will be coded. 0 means auto mode, whereby the video server inserts I-frames as necessary. An entry of 1 indicates that I-frames are continuously generated. An entry of 2 indicates that only every second image is an I-frame, and 3 only every third image etc.; the frames in between are coded as P-frames.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.20

Configuration Using a Web Browser | en

49

Video quality

This setting allows you to adjust the image quality. The Auto option automatically adjusts to the optimum combination of movement and image definition (focus). Alternatively, you can use the slide control to select a value between 1 and 100. A value of 100 results in a very high refresh rate and lower image quality.

H.264 deblocking filter

You can activate a filter that reduces blocking in the image in the case of H.264-encoded video streams, thereby providing a smoother image. Please note that this option requires additional computing power.

Priority

In the default configuration None, the computing power provided for individual tasks is negotiated dynamically. This ensures the best possible video quality at all times. With the

MPEG-4/H.264 setting, video transmissions are given a higher priority and only a small

amount of power remains available for JPEG images. The JPEG setting is suitable for applications that primarily require JPEG images, for example JPEG recordings. When this setting is made the amount of power available for video images will be reduced.

Advanced Mode: Audio

Bosch Security Systems

You can set the gain of the audio signals to suit your specific requirements. The current video image is shown in the small window next to the slide controls to help you check the audio source and improve assignments. Your changes are effective immediately.

If you connect via Web browser, you must activate the audio transmission on the LIVEPAGE

Functions page (see Section 5.15 Advanced Mode: LIVEPAGE Functions, page 42). For other

connections, the transmission depends on the audio settings of the respective system.

Audio

The audio signals are sent in a separate data stream parallel to the video data, and so increase the network load. The audio data are encoded according to G.711 and require an additional bandwidth of approx. 80 kbps for each connection. If you do not want any audio data to be transmitted, select Off.

Installation and Operating Manual DOC | V4.0 | 2009.06

50

en | Configuration Using a Web Browser

5.21

VideoJet X10 SN

Line In 1

You can set the line input gain. Make sure that the display does not go beyond the green zone during modulation.

Line Out

You can set the line output gain. Make sure that the display does not go beyond the green zone during modulation.

Advanced Mode: Storage Management

DOC | V4.0 | 2009.06

You can record the images from the camera connected to the VideoJet X10 SN on various local storage media or on an appropriately configured iSCSI system.

CF cards (see Section CF Slot, page 20) are the ideal solution for shorter storage times and

temporary recordings, for example alarm recordings or local buffering in the event of network interruptions.

if the VideoJet X10 SN has a USB hard drive, this is suitable for longer, local recordings.

For long-term, authoritative images, it is essential that you use an appropriately sized iSCSI system.

It is also possible to let the VRM Video Recording Manager control all recording when accessing an iSCSI system. This is an external program for configuring recording tasks for

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

i

!

!

Bosch Security Systems

Configuration Using a Web Browser | en

51

video servers. For further information please contact your local customer service at Bosch

Security Systems.

Device manager

If you activate the VRM option in this screen, the VRM Video Recording Manager will manage all recording and you will not be able to configure any further settings here.

CAUTION!

Activating or deactivating VRM causes the current settings to be lost; they can only be restored through reconfiguration.

Recording media

Select the required recording media here so that you can then activate them and configure the recording parameters.

iSCSI Media

If you want to use an iSCSI system as a recording medium, you must set up a connection to the required iSCSI system and set the configuration parameters.

NOTICE!

The iSCSI storage system selected must be available on the network and completely set up.

Amongst other things, it must have an IP address and be divided into logical drives (LUN).

1.

Enter the IP address of the required iSCSI destination in the iSCSI IP address field.

2.

If the iSCSI destination is password protected, enter this into the Password field.

3.

Click the Read button. The connection to the IP address will be established. In the

Storage overview field, you can see the corresponding logical drives.

Local Media

The supported local recording media are displayed in the Storage overview field.

X

If the local recording medium is password protected, enter this into the Password field.

Activating and Configuring Storage Media

The storage overview displays the available storage media. You can select individual media or iSCSI drives and transfer these to the Managed storage media list. You can activate the storage media in this list and configure them for storage.

CAUTION!

Each storage medium can only be associated with one user. If a storage medium is already being used by another user, you can decouple the user and connect the drive with the

VideoJet X10 SN. Before decoupling, make absolutely sure that the previous user no longer needs the storage medium.

1.

In the Recording media section, click the iSCSI Media and Local Media tabs to display the applicable storage media in the overview.

2.

In the Storage overview section, double-click the required storage medium, an iSCSI

LUN or one of the other available drives. The medium is then added to the Managed

storage media list. In the Status column, newly added media are indicated by the status

Not active.

3.

Click the Set button to activate all media in the Managed storage media list. In the

Status column, these are indicated by the status Online.

4.

Check the box in the Rec. 1 or Rec. 2 to specify which data stream should be recorded on the storage media selected. Rec. 1 stores Stream 1, Rec. 2 stores Stream 2. This

Installation and Operating Manual DOC | V4.0 | 2009.06

52

en | Configuration Using a Web Browser

5.22

!

!

VideoJet X10 SN means that you can record the standard data stream on a hard drive and record alarm images on the mobile CF card, for example.

5.

Check the boxes for the Overwrite older recordings option to specify which older recordings can be overwritten once the available memory capacity has been used.

Recording 1 corresponds to Stream 1, Recording 2 corresponds to Stream 2.

CAUTION!

If older recordings are not allowed to be overwritten when the available memory capacity has been used, the recording in question will be stopped. You can specify limitations for

overwriting old recordings by configuring the retention time (see Section 5.24 Advanced Mode:

Retention Time, page 55).

Formatting Storage Media

You can delete all recordings on a storage medium at any time.

CAUTION!

Check the recordings before deleting and back up important sequences on the computer's hard drive.

1.

Click a storage medium in the Managed storage media list to select it.

2.

Click the Edit button below the list. A new window will open.

3.

Click the Formatting button to delete all recordings in the storage medium.

4.

Click OK to close the window.

Deactivating Storage Media

You can deactivate any storage medium from the Managed storage media list. It is then no longer used for recordings.

1.

Click a storage medium in the Managed storage media list to select it.

2.

Click the Remove button below the list. The storage medium is deactivated and removed from the list.

Advanced Mode: Remote Video Device

DOC | V4.0 | 2009.06

You can allow a remote video device to use the VideoJet X10 SN storage media. This means you can record video images from a camera that does not have its own storage media, for example. Once you have entered the IP address of the remote video device and saved it by pressing Set, the VideoJet X10 SN is then displayed for selection in the Storage Management for the remote video device.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.23

Configuration Using a Web Browser | en

53

IP Address

Enter the IP address for the remote video device.

1.

If you do not know the IP address, click the Network Scan button. The search for possible devices in the network is started. A small arrow is then displayed next to the IP

Address field.

2.

Click the arrow to display the list of devices detected.

3.

Click the required device in the list to transfer its IP address.

Advanced Mode: Recording Profiles

i

Bosch Security Systems

You can define up to ten different recording profiles. You will then use these recording profiles in the recording scheduler, where they are linked with the individual days and times

(see Section 5.25 Advanced Mode: Recording Scheduler, page 56).

NOTICE!

You can change or add to the recording profile description on the tabs on the Recording

Scheduler page (see Section Time periods, page 57).

1.

Click one of the tabs to edit the corresponding profile.

Installation and Operating Manual DOC | V4.0 | 2009.06

54

en | Configuration Using a Web Browser

i i

!

VideoJet X10 SN

2.

If necessary, click the Default button to return all settings to their default values.

3.

Click the Copy Settings button if you want to copy the currently visible settings to other profiles. A new window will open and you can select the profiles in which you want to copy the settings.

4.

For each profile, click the Set button to save the settings in the unit.

Standard recording

Here you can select the mode for standard recordings.

If you select Continuous, the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten. If you select the Pre-

alarm option, recording will only take place in the pre-alarm time, during the alarm and during

the set post-alarm time.

If you select Off, no automatic recording takes place.

CAUTION!

You can specify limitations for overwriting older recordings in Continuous mode by

configuring the retention time (see Section 5.24 Advanced Mode: Retention Time, page 55).

Standard profile

From this field, you can select the encoder profile to be used for recording (see

Section 5.19 Advanced Mode: Encoder Profile, page 46).

NOTICE!

The recording profile can deviate from the standard setting Active profile and is only used during an active recording.

Pre-alarm time

You can select the required pre-alarm time from the list field.

Post-alarm time

You can select the required post-alarm time from the list field.

Post-alarm profile

You can select the encoder profile to be used for recording during the post-alarm time (see

Section 5.19 Advanced Mode: Encoder Profile, page 46).

The Standard profile option adopts the selection at the top of the page.

Alarm input / Motion alarm / Video loss alarm

Here you can select the alarm sensor that is to trigger a recording.

NOTICE!

The motion alarm is configured and activated on the VCA page (see Section 5.31 Advanced

Mode: VCA Event Triggered, page 68).

The alarm inputs are configured and activated on the Alarm Inputs page (see

Section 5.35 Advanced Mode: Alarm Inputs, page 73).

The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the alarm inputs on the VideoJet X10 SN.

Virtual alarm

Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.24

i

!

Configuration Using a Web Browser | en

55

NOTICE!

For more information, please see the Alarm Task Script Language document and the RCP+ documentation. These documents can be found on the product CD supplied.

Recording includes

You can specify whether, in addition to video data, audio data and metadata (for example alarms, VCA data and serial data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity.

CAUTION!

Without metadata, it is not possible to include video content analysis in recordings.

Advanced Mode: Retention Time

i

You can specify the retention times for recordings. If the available memory capacity of a medium has been used, older recordings are only overwritten if the retention time entered here has expired.

NOTICE!

Make sure that the retention time corresponds with the available memory capacity. A rule of thumb for the memory requirement is as follows: 1 GB per hour retention time with 4CIF for complete frame rate and high image quality.

Retention time Camera 1

Enter the required retention time in hours or days for each recording. Recording 1 corresponds to Stream 1, Recording 2 corresponds to Stream 2.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

56

en | Configuration Using a Web Browser

5.25

Advanced Mode: Recording Scheduler

VideoJet X10 SN

The recording scheduler allows you to link the created recording profiles with the days and times at which the camera's images are to be recorded in the event of an alarm.

You can link any number of 15-minute intervals with the recording profiles for each day of the week. Moving the mouse cursor over the table displays the time below it. This aids orientation.

In addition to the normal weekdays, you can define holidays that are not in the standard weekly schedule on which recordings are to apply. This allows you to apply a schedule for

Sundays to other days with dates that fall on varying weekdays.

1.

Click the profile you want to link in the Time periods field.

2.

Click in a field in the table, hold down the mouse button and drag the cursor over all the periods to be assigned to the selected profile.

3.

Use the right mouse button to deselect any of the intervals.

4.

Click the Select All button to link all time intervals to the selected profile.

5.

Click the Clear All button to deselect all of the intervals.

6.

When you are finished, click the Set button to save the settings in the unit.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Configuration Using a Web Browser | en

57

Holidays

You can define holidays that are not in the standard weekly schedule on which recordings are to apply. This allows you to apply a schedule for Sundays to other days with dates that fall on varying weekdays.

1.

Click the Holidays tab. Any days that have already been selected will be shown in the table.

2.

Click the Add button. A new window will open.

3.

Select the desired date from the calendar. You can select several consecutive calendar days by holding down the mouse button. These will later be displayed as a single entry in the table.

4.

Click OK to accept the selection. The window will close.

5.

Assign the individual holidays to the recording profiles, as described above.

Deleting Holidays

You can delete holidays you have defined yourself at any time.

1.

Click the Delete button. A new window will open.

2.

Click the date you wish to delete.

3.

Click OK. The item will be deleted from the table and the window will close.

4.

The process must be repeated for deleting additional days.

Time periods

You can change the names of the recording profiles.

1.

Click a profile and then the Rename button.

2.

Enter your chosen name and then click the Rename button again.

Activating the Recording

After completing configuration you must activate the recording scheduler and start the recording. Once recording is underway, the Recording Profiles and Recording Scheduler pages are deactivated and the configuration cannot be modified.

You can stop the recording activity at any time and modify the settings.

1.

Click the Start button to activate the recording scheduler.

2.

Click the Stop button to deactivate the recording scheduler. Running recordings are interrupted and the configuration can be changed.

Recording status

The graphic indicates the recording activity of the VideoJet X10 SN. You will see an animated graphic while recording is taking place.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

58

en | Configuration Using a Web Browser

5.26

Advanced Mode: Recording Status

VideoJet X10 SN

5.27

Certain details on the recording status are displayed here for information purposes. You cannot change any of these settings.

Advanced Mode: Alarm Connections

DOC | V4.0 | 2009.06

You can select how the VideoJet X10 SN responds to an alarm. In the event of an alarm, the unit can automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to which the VideoJet X10 SN will connect in sequence in the event of an alarm, until a connection is made.

Connect on alarm

Select On so that the VideoJet X10 SN automatically connects to a predefined IP address in the event of an alarm.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

i i

!

Configuration Using a Web Browser | en

59

By setting Follows input 1 the unit maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1.

NOTICE!

In the default setting, Stream 2 is transmitted for alarm connections. Bear this fact in mind

when assigning the profile (see Section 5.19 Advanced Mode: Encoder Profile, page 46).

Number of destination IP address

Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit contacts the remote stations one after the other in the numbered sequence until a connection is made.

Destination IP address

For each number, enter the corresponding IP address for the desired remote station.

Destination password

If the remote station is password protected, enter the password here.

In this page, you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations. If connections to more than ten remote stations are to be possible, for example when initiating connections via higher-ranking systems such as

VIDOS or Bosch Video Management System, you can store a general password here. The

VideoJet X10 SN can use this general password to connect to all remote stations protected with the same password. In this case, proceed as follows:

1.

Select 10 from the Number of destination IP address list field.

2.

Enter the address 0.0.0.0 in the Destination IP address field.

3.

Enter your chosen password in the Destination password field.

4.

Define this password as the user password for all remote stations to which a connection is to be possible.

NOTICE!

If you enter the destination IP address 0.0.0.0 for destination 10, this VideoJet X10 SN address will no longer be used for the tenth attempt at automatic connection in the event of an alarm. The parameter is then used only to save the general password.

Video transmission

If the unit is operated behind a firewall, TCP (HTTP port) should be selected as the transfer protocol. For use in a local network, select UDP.

CAUTION!

Please note that in some circumstances, a larger bandwidth must be available on the network for additional video images in the event of an alarm, in case Multicast operation is not possible. To enable Multicast operation, select the UDP option for the Video transmission

parameter here and on the Network page (see Section Video transmission, page 77).

Remote port

Depending on the network configuration, select a browser port here. The ports for HTTPS connections will be available only if the On option is selected in the SSL encryption parameter.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

60

en | Configuration Using a Web Browser

i i i

VideoJet X10 SN

Video output

If you know which unit is being used as the receiver, you can select the analog video output to which the signal should be switched. If the destination unit is unknown, it is advisable to select the First available option. In this case, the image is placed on the first free video output. This is an output on which there is no signal. The connected monitor only displays images when an alarm is triggered. If you select a particular video output and a split image is set for this output on the receiver, you can also select from Decoder the decoder in the receiver that is to be used to display the alarm image.

NOTICE!

Refer to the destination unit documentation concerning image display options and available video outputs.

Decoder

Select a decoder of the receiver to display the alarm image. The decoder selected has an impact on the position of the image in a split screen. For example, you can specify via a VIP XD that the upper-right quadrant should be used to display the alarm image by selecting decoder

2.

SSL encryption

The data for the connection, for example the password, can be securely transmitted with SSL encryption. If you have selected the On option, only encrypted ports are offered in the

Remote port parameter.

NOTICE!

Please note that the SSL encryption must be activated and configured at both ends of a connection. This requires the appropriate certificates to be uploaded onto the

VideoJet X10 SN (see Section Maintenance log, page 85).

You can activate and configure encryption of the media data (video, audio and metadata) on

the Encryption page (see Section 5.42 Advanced Mode: Encryption, page 83).

Auto-connect

Select the On option to automatically re-establish a connection to one of the previously specified IP addresses after each reboot, after a connection breakdown or after a network failure.

NOTICE!

In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in

mind when assigning the profile (see Section 5.19 Advanced Mode: Encoder Profile, page 46).

Audio

Select the On option if you wish to additionally transmit a standalone G.711 encoded audio stream with alarm connections.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.28

Advanced Mode: VCA

Configuration Using a Web Browser | en

61

The VideoJet X10 SN contains an integrated video content analysis (VCA), which can detect and analyze changes in the signal on the basis of image processing. Such changes can be due to movements in the camera's field of view.

You can select various VCA configurations and adapt these to your application as required.

The Silent MOTION+ configuration is active by default. In this configuration, metadata is created to facilitate searches of recordings; however, no alarm is triggered.

1.

Select a VCA configuration and make the required settings.

2.

If necessary, click the Default button to return all settings to their default values.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

62

en | Configuration Using a Web Browser

5.29

Advanced Mode: VCA Profiles

VideoJet X10 SN

i

You can configure two profiles with different VCA configurations. You can save profiles on your computer's hard drive and load saved profiles from there. This can be useful if you want to test a number of different configurations. Save a functioning configuration and test new settings. You can use the saved configuration to restore the original settings at any time.

NOTICE!

If computing power becomes short, the highest priority is always the live images and recordings. This can lead to impairment of the video content analysis. You should therefore observe the processor load and optimize the encoder settings or the video content analysis

settings as necessary (see Section 8.6 Network Connection, page 108).

1.

Select a VCA profile and enter the required settings.

2.

If necessary, click the Default button to return all settings to their default values.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

i i

!

Configuration Using a Web Browser | en

63

3.

Click the Save... button to save the profile settings to another file. A new window is opened, in which you can specify where you want to save the file and what name you want to save it under.

4.

Click the Load... button to load a saved profile. A new window opens in which you can select the profile file and specify where to save the file.

VCA configuration

Select one of the profiles here to activate it or edit it.

You can rename the profile.

1.

To rename the file, click the icon to the right of the list field and enter the new profile name in the field.

2.

Click the icon again. The new profile name is saved.

Alarm status

The alarm status is displayed here for information purposes. This means you can check the effects of your settings immediately.

Analysis type

Select the required analysis algorithm. By default, only MOTION+ is available – this offers a motion detector and essential recognition of tampering.

NOTICE!

Additional analysis algorithms with comprehensive functions such as IVMD and IVA are available from Bosch Security Systems.

If you select one of these algorithms, you can set the corresponding parameters here directly.

You can find information on this in the relevant documents on the product CD supplied.

Metadata is always created for a video content analysis, unless this was explicitly excluded.

Depending on the analysis type selected and the relevant configuration, additional information overlays the video image in the preview window next to the parameter settings.

With the MOTION+ analysis type, for example, the sensor fields in which motion is recorded will be marked with rectangles.

NOTICE!

On the LIVEPAGE Functions page, you can also enable additional information overlays for the

LIVEPAGE (see Section 5.15 Advanced Mode: LIVEPAGE Functions, page 42).

Motion detector (MOTION+ only)

For the detector to function, the following conditions must be met:

– Analysis must be activated.

– At least one sensor field must be activated.

– The individual parameters must be configured to suit the operating environment and the desired responses.

– The sensitivity must be set to a value greater than zero.

CAUTION!

Reflections of light (off glass surfaces, etc.), switching lights on or off or changes in the light level caused by cloud movement on a sunny day can trigger unintended responses from the motion detector and generate false alarms. Run a series of tests at different times of the day and night to ensure that the video sensor is operating as intended.

For indoor surveillance, ensure constant lighting of the areas during the day and at night.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

64

en | Configuration Using a Web Browser VideoJet X10 SN

i

Sensitivity (MOTION+ only)

The basic sensitivity of the motion detector can be adjusted for the environmental conditions to which the camera is subject.

The sensor reacts to variations in the brightness of the video image. The darker the observation area, the higher the value that must be selected.

Minimum object size (MOTION+ only)

You can specify the number of sensor fields that a moving object must cover to generate an alarm. This is to prevent objects that are too small from triggering an alarm.

A minimum value of 4 is recommended. This value corresponds to four sensor fields.

Select Area (MOTION+ only)

The areas of the image to be monitored by the motion detector can be selected. The video image is subdivided into 858 square fields. Each of these fields can be activated or deactivated individually. If you wish to exclude particular regions of the camera's field of view from monitoring due to continuous movement (by a tree in the wind, etc.), the relevant fields can be deactivated.

1.

Click Select Area to configure the sensor fields. A new window will open.

2.

If necessary, click Clear All first to clear the current selection (fields marked yellow).

3.

Left-click the fields to be activated. Activated fields are marked yellow.

4.

If necessary, click Select All to select the entire video frame for monitoring.

5.

Right-click any fields you wish to deactivate.

6.

Click OK to save the configuration.

7.

Click the close button X in the window title bar to close the window without saving the changes.

Tamper detection

You can reveal the tampering of cameras and video cables by means of various options. Run a series of tests at different times of the day and night to ensure that the video sensor is operating as intended.

NOTICE!

The options for tamper detection can only be set for fixed cameras. Dome cameras or other motorized cameras cannot be protected in this manner as the movement of the camera itself causes changes in the video image that are too great.

Sensitivity

NOTICE!

This and the following parameter are only accessible if the reference check is activated.

i

DOC | V4.0 | 2009.06

The basic sensitivity of the tamper detection can be adjusted for the environmental conditions to which the camera is subject.

The algorithm reacts to the differences between the reference image and the current video image. The darker the observation area, the higher the value that must be selected.

Trigger delay (s)

You can set delayed alarm triggering. The alarm is only triggered after a set time interval in seconds has elapsed and then only if the triggering condition still exists. If the original condition has been restored before this time interval elapses, the alarm is not triggered. This allows you to avoid false alarms triggered by short-term changes, for example cleaning activities in the direct field of vision of the camera.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Configuration Using a Web Browser | en

65 i

Bosch Security Systems

Global change

You can set how large the global change in the video image must be for an alarm to be triggered. This setting is independent of the sensor fields selected under Select Area. Set a high value if fewer sensor fields need to change to trigger an alarm. With a low value, it is necessary for changes to occur simultaneously in a large number of sensor fields to trigger an alarm.

This option allows you to detect, independently of motion alarms, manipulation of the orientation or location of a camera resulting from turning the camera mount bracket, for instance.

Global change

Activate this function if the global change, as set with the Global change slide control, should trigger an alarm.

Scene too bright

Activate this function if tampering associated with exposure to extreme light (for instance, shining a flashlight directly on the lens) should trigger an alarm. The average brightness of the scene provides a basis for recognition.

Scene too dark

Activate this function if tampering associated with covering the lens (for instance, by spraying paint on it) should trigger an alarm. The average brightness of the scene provides a basis for recognition.

Scene too noisy

Activate this function if tampering associated with EMC interference (noisy scene as the result of a strong interference signal in the vicinity of the video lines), as an example, should trigger an alarm.

Reference check

You can save a reference image that is continuously compared with the current video image. If the current video image in the marked areas differs from the reference image, an alarm is triggered. This allows you to detect tampering that would otherwise not be detected, for example if the camera is turned.

1.

Click Reference to save the currently visible video image as a reference.

2.

Click Select Area and select the areas in the reference image that are to be monitored.

3.

Check the box Reference check to activate on-going matching. The stored reference image is displayed in black and white below the current video image, and the selected areas are marked in yellow.

4.

Select the Disappearing edges or Appearing edges option to specify the reference check once again.

Select Area

You can select the image areas in the reference image that are to be monitored. The video image is subdivided into 858 square fields. Each of these fields can be activated or deactivated individually.

NOTICE!

Select only those areas for reference monitoring in which no movement takes place and that are always evenly lit, as false alarms could otherwise be triggered.

1.

Click Select Area to configure the sensor fields. A new window will open.

2.

If necessary, click Clear All first to clear the current selection (fields marked yellow).

Installation and Operating Manual DOC | V4.0 | 2009.06

66

en | Configuration Using a Web Browser

5.30

VideoJet X10 SN

3.

Left-click the fields to be activated. Activated fields are marked yellow.

4.

If necessary, click Select All to select the entire video frame for monitoring.

5.

Right-click any fields you wish to deactivate.

6.

Click OK to save the configuration.

7.

Click the close button X in the window title bar to close the window without saving the changes.

Advanced Mode: VCA Scheduled

DOC | V4.0 | 2009.06

This configuration allows you to link the created VCA profile with the days and times at which the video content analysis is to be active.

You can link any number of 15-minute intervals with the VCA profiles for each day of the week.

Moving the mouse cursor over the table displays the time below it. This aids orientation.

In addition to the normal weekdays, you can define holidays that are not in the standard weekly schedule on which recordings are to apply. This allows you to apply a schedule for

Sundays to other days with dates that fall on varying weekdays.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Configuration Using a Web Browser | en

67

1.

Click the profile you want to link in the Time periods field.

2.

Click in a field in the table, hold down the mouse button and drag the cursor over all the periods to be assigned to the selected profile.

3.

Use the right mouse button to deselect any of the intervals.

4.

Click the Select All button to link all time intervals to the selected profile.

5.

Click the Clear All button to deselect all of the intervals.

6.

When you are finished, click the Set button to save the settings in the unit.

Holidays

You can define holidays on which a profile should be active that are different to the standard weekly schedule. This allows you to apply a schedule for Sundays to other days with dates that fall on varying weekdays.

1.

Click the Holidays tab. Any days that have already been selected will be shown in the table.

2.

Click the Add button. A new window will open.

3.

Select the desired date from the calendar. You can select several consecutive calendar days by holding down the mouse button. These will later be displayed as a single entry in the table.

4.

Click OK to accept the selection. The window will close.

5.

Assign the individual holidays to the VCA profiles, as described above.

Deleting Holidays

You can delete holidays you have defined yourself at any time.

1.

Click the Delete button. A new window will open.

2.

Click the date you wish to delete.

3.

Click OK. The item will be deleted from the table and the window will close.

4.

The process must be repeated for deleting additional days.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

68

en | Configuration Using a Web Browser

5.31

Advanced Mode: VCA Event Triggered

VideoJet X10 SN

i

DOC | V4.0 | 2009.06

This configuration allows you stipulate that the video content analysis is only to be activated when triggered by an event. As long as no trigger is activated, the Silent MOTION+ configuration in which metadata is created is active; this metadata facilitates searches of recordings, but does not trigger an alarm.

Trigger

You can select one of the physical alarms on the device's alarm inputs or one of the virtual alarms as a trigger. A virtual alarm is created using software, with RCP+ commands or alarm scripts, for example.

NOTICE!

For more information, please see the Alarm Task Script Language document and the RCP+ documentation. You can find these documents on the product CD supplied (see

Section 3.1 Scope of Delivery, page 11).

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.32

Configuration Using a Web Browser | en

69

Trigger active

Select the VCA configuration here that is to be enabled via an active trigger. A green check mark to the right of the list field indicates that the trigger is active.

Trigger inactive

Select the VCA configuration here that is to be activated if the trigger is not active. A green check mark to the right of the list field indicates that the trigger is inactive.

Delay (s)

Select the delay period here for the reaction of the video content analysis to trigger signals. A delay period may be useful in avoiding false alarms or frequent triggering, for example. During the delay period, the Silent MOTION+ configuration is always enabled.

Advanced Mode: Audio Alarm

i

The VideoJet X10 SN can create alarms on the basis of audio signals. You can configure signal strengths and frequency ranges in such a way that false alarms, for example due to machine noise or background noise, are avoided.

NOTICE!

First set up normal audio transmission before you configure the audio alarm here (see

Section 5.20 Advanced Mode: Audio, page 49).

Audio alarm

Select On if you want the device to generate audio alarms.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

70

en | Configuration Using a Web Browser

5.33

!

VideoJet X10 SN

Name

The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the VIDOS and Bosch Video Management System programs. Enter a unique and clear name here.

CAUTION!

Do not use any special characters, for example &, in the name.

Special characters are not supported by the system's internal recording management and may therefore result in the Player or Archive Player being unable to play back the recording.

Threshold

Set up the threshold on the basis of the signal visible in the graphic You can set the threshold using the slide control or, alternatively, you can move the white line directly in the graphic using the mouse.

Sensitivity

You can use this setting to adapt the sensitivity to the sound environment. You can effectively suppress individual signal peaks. A high value represents a high level of sensitivity.

Signal Ranges

You can exclude particular signal ranges in order to avoid false alarms. For this reason the total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the graphic to include or exclude individual ranges.

Advanced Mode: Alarm E-Mail

DOC | V4.0 | 2009.06

As an alternative to automatic connecting, alarm states can also be documented by e-mail. In this way it is possible to notify a recipient who does not have a video receiver. In this case, the

VideoJet X10 SN automatically sends an e-mail to a previously defined e-mail address.

Send alarm e-mail

Select On if you want the unit to automatically send an alarm e-mail in the event of an alarm.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

!

Configuration Using a Web Browser | en

71

Mail server IP address

Enter the IP address of a mail server that operates on the SMTP standard (Simple Mail

Transfer Protocol). Outgoing e-mails are sent to the mail server via the address you entered.

Otherwise leave the box blank (0.0.0.0).

SMTP user name

Enter a registered user name for the chosen mailserver here.

SMTP password

Enter the required password for the registered user name here.

Format

You can select the data format of the alarm message.

Standard (with JPEG)

E-mail with attached JPEG image file.

SMS

E-mail in SMS format to an e-mail-to-SMS gateway (for example to send an alarm by cellphone) without an image attachment.

CAUTION!

When a cellphone is used as the receiver, make sure to activate the e-mail or SMS function, depending on the format, so that these messages can be received.

You can obtain information on operating your cellphone from your cellphone provider.

Attach JPEG from camera

Click the checkbox to specify that JPEG images are sent from the camera. An enabled video input is indicated by a check mark.

Destination address

Enter the e-mail address for alarm e-mails here. The maximum address length is 49 characters.

Sender name

Enter a unique name for the e-mail sender, for example the location of the unit. This will make it easier to identify the origin of the e-mail.

Test e-mail

You can test the e-mail function by clicking the Send Now button. An alarm e-mail is immediately created and sent.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

72

en | Configuration Using a Web Browser

5.34

Advanced Mode: Alarm Task Editor

VideoJet X10 SN

!

CAUTION!

Editing scripts on this page overwrites all settings and entries on the other alarm pages. This procedure cannot be reversed.

In order to edit this page, you must have programming knowledge and be familiar with the information in the Alarm Task Script Language document. You can find the document on the

product CD supplied (see Section 3.1 Scope of Delivery, page 11).

As an alternative to the alarm settings on the various alarm pages, you can enter your desired alarm functions in script form here. This will overwrite all settings and entries on the other alarm pages.

1.

Click the Examples link under the Alarm Task Editor field to see some script examples. A new window will open.

2.

Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your requirements.

3.

When you are finished, click the Set button to transmit the scripts to the unit. If the transfer was successful, the message Script successfully parsed is displayed over the text field. If it was not successful, an error message will be displayed with further information.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.35

Advanced Mode: Alarm Inputs

Configuration Using a Web Browser | en

73

5.36

You can configure the alarm inputs of the VideoJet X10 SN.

Alarm input

Select Active high if the alarm is to be triggered when the contact closes. Select Active low if the alarm is to be triggered when the contact opens.

Name

You can enter a name for each alarm input, which is then displayed below the icon for the

alarm input on the LIVEPAGE if configured correctly (see Section 5.15 Advanced Mode:

LIVEPAGE Functions, page 42).

Advanced Mode: Relay

Bosch Security Systems

You can configure the switching behavior of the relay outputs. For each relay, you can specify an open switch relay (normally closed contact) or a closed switch relay (normally open contact).

You can also specify whether an output should operate as a bistable or monostable relay. In bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set the time after which the relay will return to the idle state.

You can select different events that automatically activate an output. It is possible, for example, to turn on a floodlight by triggering a motion alarm and then turning the light off again when the alarm has stopped.

Idle state

Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is to operate as an NC contact.

Installation and Operating Manual DOC | V4.0 | 2009.06

74

en | Configuration Using a Web Browser

i

VideoJet X10 SN

Operating mode

Select an operating mode for the relay.

For example, if you want an alarm-activated lamp to stay on after the alarm ends, select

Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select

10 s.

Relay follows

If required, select a specific event that will trigger the relay. The following events are possible triggers:

Off

Relay is not triggered by events

Connection

Trigger whenever a connection is made

Video alarm

Trigger by interruption of the video signal

Motion alarm

Trigger by motion alarm, as configured on the VCA page (see Section 5.31 Advanced

Mode: VCA Event Triggered, page 68)

Local input

Trigger by the corresponding external alarm input

Remote input

Trigger by remote station's corresponding switching contact (only if a connection exists)

NOTICE!

The numbers in the lists of selectable events relate to the corresponding connections on the unit, Video alarm 1, for example to the Video In connection.

Relay name

You can assign a name for the relay here. The name is shown on the button next to Trigger

relay. The Livepage can also be configured to display the name under the relay icon.

Trigger relay

Click the button to trigger the relay manually (for testing or to operate a door opener, for example).

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.37

Advanced Mode: COM1

Configuration Using a Web Browser | en

75 i i

Bosch Security Systems

You can configure the serial interface parameters (orange terminal block) to meet your requirements.

NOTICE!

If the VideoJet X10 SN is working in multicast mode (see Section 5.40 Advanced Mode:

Multicasting, page 81), the first remote location to establish a video connection to the unit is

also assigned the transparent data connection. However, after about 15 seconds of inactivity the data connection is automatically terminated and another remote location can exchange transparent data with the unit.

Serial port function

Select a controllable unit from the list. If you wish to use the serial port to transmit transparent data, select Transparent. Select Terminal if you wish to operate the unit from a terminal.

NOTICE!

After selecting a unit, the remaining parameters in the window are set automatically and should not be changed.

Camera ID

If necessary, enter the ID of the peripheral you wish to control (for example a dome camera or pan/tilt head).

Baud rate

Select the value for the transmission rate in bps.

Data bits

The number of data bits per character cannot be changed.

Stop bits

Select the number of stop bits per character.

Parity check

Select the type of parity check.

Interface mode

Select the desired protocol for the serial interface.

Installation and Operating Manual DOC | V4.0 | 2009.06

76

en | Configuration Using a Web Browser

5.38

Advanced Mode: Network

VideoJet X10 SN

DOC | V4.0 | 2009.06

The settings on this page are used to integrate the VideoJet X10 SN into an existing network.

Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.

1.

Make the desired changes.

2.

Click the Set and Reboot button. The VideoJet X10 SN is rebooted and the changed settings are activated.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

!

!

Configuration Using a Web Browser | en

77

CAUTION!

If you change the IP address, subnet mask or gateway address, the VideoJet X10 SN is only available under the new addresses after the reboot.

Automatic IP assignment

If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you can activate acceptance of IP addresses automatically assigned to the VideoJet X10 SN.

Certain applications (VIDOS, Bosch Video Management System, Archive Player, Configuration

Manager) use the IP address for the unique assignment of the unit. If you use these applications, the DHCP server must support the fixed assignment between IP address and

MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted.

IP address

Enter the desired IP address for the VideoJet X10 SN in this field. The IP address must be valid for the network.

Subnet mask

Enter the appropriate subnet mask for the selected IP address here.

Gateway address

If you want the unit to establish a connection to a remote location in a different subnet, enter the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).

DNS server address

The unit can use a DNS server to trigger an address specified as a name. Enter the IP address of the DNS server here.

Video transmission

If the unit is operated behind a firewall, TCP (HTTP port) should be selected as the transfer protocol. For use in a local network, select UDP.

CAUTION!

Multicast operation is only possible with the UDP protocol. The TCP protocol does not support multicast connections.

The MTU value in UDP mode is 1,514 bytes.

HTTP browser port

Select a different HTTP browser port from the list if required. The default HTTP port is 80. If you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In this case, select Off.

HTTPS browser port

If you wish to allow browser access on the network via a secure connection, select an HTTPS browser port from the list if necessary. The default HTTPS port is 443. Select the Off option to deactivate HTTPS ports; only unsecured connections will now be possible.

The VideoJet X10 SN uses the TLS 1.0 encryption protocol. You may have to activate this protocol via your browser configuration. You must also activate the protocol for the Java applications (via the Java control panel in the Windows control panel).

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

78

en | Configuration Using a Web Browser

i i

VideoJet X10 SN

NOTICE!

If you want to allow only secure connections with SSL encryption, you must select the Off option for each of the parameters HTTP browser port, RCP+ port 1756 and Telnet support.

This deactivates all unsecured connections. Connections will then only be possible via the

HTTPS port.

You can activate and configure encryption of the media data (video, audio and metadata) on

the Encryption page (see Section 5.42 Advanced Mode: Encryption, page 83).

RCP+ port 1756

To exchange connection data, you can activate the unsecured RCP+ port 1756. If you want connection data to be transmitted only when encrypted, select the Off option to deactivate the port.

Telnet support

If you want to allow only secure connections with encrypted data transmission, you must select the Off option to deactivate Telnet support. The unit will then no longer be accessible using the Telnet protocol.

Interface mode ETH

If necessary, select the Ethernet link type for the ETH interface. Depending on the unit connected, it may be necessary to select a special operation type.

Network MSS (Byte)

You can set the maximum segment size for the IP packet's user data. This gives you the option to adjust the size of the data packets to the network environment and to optimize data transmission. Please comply with the MTU value of 1,514 bytes in UDP mode.

iSCSI MSS (Byte)

You can specify a higher MSS value for a connection to the iSCSI system than for the other data traffic via the network. The potential value depends on the network structure. A higher value is only useful if the iSCSI system is located in the same subnet as the VideoJet X10 SN.

Enable DynDNS

DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use. It allows you to select the VideoJet X10 SN via the Internet using a host name, without having to know the current IP address of the unit. You can enable this service here. To do this, you must have an account with DynDNS.org and you must have registered the required host name for the unit on that site.

NOTICE!

Information about the service, registration process and available host names can be found at

DynDNS.org.

Host name

Enter the host name registered on DynDNS.org for the VideoJet X10 SN here.

User name

Enter the user name you registered at DynDNS.org here.

Password

Enter the password you registered at DynDNS.org here.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.39

Configuration Using a Web Browser | en

79

Force registration now

You can force the registration by transferring the IP address to the DynDNS server. Entries that change frequently are not provided in the Domain Name System. It is a good idea to force the registration when you are setting up the device for the first time. Only use this function when necessary and no more than once a day, to avoid the possibility of being blocked by the service provider. To transfer the IP address of the VideoJet X10 SN, click the Register button.

Status

The status of the DynDNS function is displayed here for information purposes. You cannot change any of these settings.

Advanced Mode: Advanced

The settings on this page are used to implement advanced settings for the network.

Some changes only take effect after the unit is rebooted. In this case, the Set button changes to Set and Reboot.

1.

Make the desired changes.

2.

Click the Set and Reboot button. The VideoJet X10 SN is rebooted and the changed settings are activated.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

80

en | Configuration Using a Web Browser VideoJet X10 SN

SNMP

The VideoJet X10 SN supports the SNMP V2 (Simple Network Management Protocol) for managing and monitoring network components, and can send SNMP messages (traps) to IP addresses. The unit supports SNMP MIB II in the unified code. If you wish to send SNMP traps, enter the IP addresses of one or two required target devices here.

If you select On for the SNMP parameter and do not enter an SNMP host address, the

VideoJet X10 SN does not send them automatically, but only replies to SNMP requests. If you enter one or two SNMP host addresses, SNMP traps are sent automatically. Select Off to deactivate the SNMP function.

1. SNMP host address / 2. SNMP host address

If you wish to send SNMP traps automatically, enter the IP addresses of one or two required target units here.

SNMP traps

You can select which traps are to be sent.

1.

Click Select. A list is opened.

2.

Click the checkboxes to select the required traps. All the checked traps will be sent.

3.

Click Set to accept the selection.

Authentication

If a RADIUS server is employed in the network for managing access rights, authentication must be activated here to allow communication with the unit. The RADIUS server must also contain the corresponding data.

To configure the unit, you must connect the VideoJet X10 SN directly to a computer using a network cable. This is because communication via the network is not enabled until the

Identity and Password parameters have been set and successfully authenticated.

Identity

Enter the name that the RADIUS server is to use for identifying the VideoJet X10 SN.

Password

Enter the password that is stored in the RADIUS server.

RTSP port

If necessary, select a different port for the exchange of the RTSP data from the list. The standard RTSP port is 554. Select Off to deactivate the RTSP function.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.40

Advanced Mode: Multicasting

Configuration Using a Web Browser | en

81 i i

In addition to a 1:1 connection between an encoder and a single receiver (unicast), the

VideoJet X10 SN can enable multiple receivers to receive the video signal from an encoder simultaneously. The device either duplicates the data stream itself and then distributes it to multiple receivers (Multi-unicast) or it sends a single data stream to the network, where the data stream is simultaneously distributed to multiple receivers in a defined group (Multicast).

You can enter a dedicated multicast address and port for each stream. You can switch between the streams by clicking the appropriate tabs.

NOTICE!

Multicast operation requires a multicast-enabled network that uses the UDP and the Internet

Group Management IGMP protocols. Other group management protocols are not supported.

The TCP protocol does not support multicast connections.

A special IP address (class D address) must be configured for multicast operation in a multicast-enabled network.

The network must support group IP addresses and the Internet Group Management Protocol

(IGMP V2). The address range is from 225.0.0.0 to 239.255.255.255.

The multicast address can be the same for multiple streams. However, it will be necessary to use a different port in each case so that multiple data streams are not sent simultaneously using the same port and multicast address.

NOTICE!

The settings must be made individually for each stream.

Enable

To enable simultaneous data reception on several receivers you need to activate the multicast function. To do this, check the box. You can then enter the multicast address.

Multicast Address

Enter a valid multicast address for each stream to be operated in multicast mode (duplication of the data streams in the network).

With the setting 0.0.0.0 the encoder for the relevant stream operates in multi-unicast mode

(copying of data streams in the unit). The VideoJet X10 SN supports multi-unicast connections for up to five simultaneously connected receivers.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

82

en | Configuration Using a Web Browser

5.41

i

VideoJet X10 SN

NOTICE!

Duplication of data places a heavy demand on the unit and can lead to impairment of the image quality under certain circumstances.

Port

Assign a different port to each data stream if there are simultaneous data streams at the same multicast address.

Enter the port address of the required stream here.

Streaming

Click the checkbox to activate multicast streaming mode for the relevant stream. An enabled stream is indicated by a check mark.

For normal multicast operation, streaming is typically not required.

Multicast packet TTL

You can enter a value to specify how long the multicast data packets are active on the network. This value must be greater than one if multicast is to be run via a router.

Advanced Mode: JPEG Posting

DOC | V4.0 | 2009.06

You can save individual JPEG images on an FTP server at specific intervals. You can then retrieve these images at a later date to reconstruct alarm events if required.

Image size

Select the resolution you wish the JPEG images to have:

Small

176 × 144/120 pixels (QCIF)

Medium

352 × 288/240 pixels (CIF)

Large

704 × 576/480 pixels (4CIF)

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.42

i

Configuration Using a Web Browser | en

83

File name

You can select how file names will be created for the individual images that are transmitted.

Overwrite

The same file name is always used and any existing file will be overwritten with the current file.

Increment

A number from 000 to 255 is added to the file name and automatically incremented by 1.

When it reaches 255 it starts again from 000.

Date/time suffix

The date and time are automatically added to the file name. When setting this parameter, ensure that the unit's date and time are always correctly set. Example: the file snap011005_114530.jpg was stored on October 1, 2005 at 11:45 and 30 seconds.

Posting interval

Enter the interval in seconds at which the images will be sent to an FTP server. Enter zero if you do not want any images to be sent.

FTP server IP address

Enter the IP address of the FTP server on which you wish to save the JPEG images.

FTP server login

Enter your login name for the FTP server.

FTP server password

Enter the password that gives you access to the FTP server.

Path on FTP server

Enter the exact path on which you wish to post the images on the FTP server.

NOTICE!

The creation of JPEG images has a lower priority than video encoding and image analysis.

Thiscan result in JPEG images being created with a delay of up to several seconds after the triggering event. If reliable, real-time recording of the alarm is required, ensure that the encoder has enough computing power available.

Advanced Mode: Encryption

A special license, with which you will receive a corresponding activation key, is required to encrypt user data. You can enter the activation key to release the function on the Licenses

page (see Section 5.44 Advanced Mode: Licenses, page 86).

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

84

en | Configuration Using a Web Browser

5.43

Advanced Mode: Maintenance

VideoJet X10 SN

!

DOC | V4.0 | 2009.06

Firmware

The VideoJet X10 SN is designed in such a way that its functions and parameters can be updated with firmware. To do this, transfer the current firmware package to the unit via the selected network. It will then be automatically installed there.

In this way, a VideoJet X10 SN can be serviced and updated remotely without a technician having to change the installation on site.

You obtain the current firmware from your customer service or from the download area at www.boschsecurity.com.

CAUTION!

Before launching the firmware upload make sure that you have selected the correct upload file. Uploading the wrong files can result in the unit no longer being addressable, in which case you must replace the unit.

You should never interrupt the installation of firmware. An interruption can lead to the flash-

EPROM being incorrectly programmed. This in turn can result in the unit no longer being addressable, in which case it will have to be replaced. Even changing to another page or closing the browser window leads to an interruption.

1.

First store the firmware file on your hard drive.

2.

Enter the full path of the firmware file in the field or click Browse to locate and select the file.

3.

Next, click Upload to begin transferring the file to the unit. The progress bar allows you to monitor the transfer.

The new firmware is unpacked and the Flash EPROM is reprogrammed. The time remaining is shown by the message going to reset Reconnecting in ... seconds. The unit reboots automatically once the upload has successfully completed.

If the Connect LED lights up red, the upload has failed and must be repeated. To perform the upload you must now switch to a special page:

1.

In the address bar of your browser, enter /main.htm after the IP address of the

VideoJet X10 SN (for example 192.168.0.10/main.htm).

2.

Repeat the upload.

Configuration

You can save configuration data for the VideoJet X10 SN on a computer and then load saved configuration data from a computer to the unit.

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

i

Configuration Using a Web Browser | en

85

Upload

1.

Enter the full path of the file to upload or click Browse to select the required file.

2.

Make certain that the file to be loaded comes from the same unit type as the unit you want to configure.

3.

Next, click Upload to begin transferring the file to the unit. The progress bar allows you to monitor the transfer.

Once the upload is complete, the new configuration is activated. The time remaining is shown by the message going to reset Reconnecting in ... seconds. The unit reboots automatically once the upload has successfully completed.

Download

1.

Click the Download button. A dialog box opens.

2.

Follow the on-screen instructions to save the current settings.

SSL certificate

To be able to work with an SSL encrypted data connection, both ends of a connection must hold the relevant certificates. You can upload the SSL certificate, comprising one or multiple files, onto the VideoJet X10 SN.

If you wish to upload multiple files onto the VideoJet X10 SN, you must select them consecutively.

NOTICE!

The certificate must be created in the format *.pem so that it can be accepted by the unit.

1.

Enter the full path of the file to upload or click Browse to select the required file.

2.

Next, click Upload to begin transferring the file to the unit.

3.

Once all files have been successfully uploaded, the unit must be rebooted. In the address bar of your browser, enter /reset after the IP address of the VideoJet X10 SN (for example 192.168.0.10/reset).

The new SSL certificate is valid.

Maintenance log

You can download an internal maintenance log from the unit to send it to Customer Service for support purposes. Click Download and select a storage location for the file.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

VideoJet X10 SN

86

en | Configuration Using a Web Browser

5.44

Advanced Mode: Licenses

5.45

i

You can enter the activation key to release additional functions or software modules.

NOTICE!

The activation key cannot be deactivated again and is not transferable to other units.

Advanced Mode: System Overview

i

The data on this page are for information purposes only and cannot be changed. Keep a record of this information in case technical assistance is required.

NOTICE!

You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

5.46

Configuration Using a Web Browser | en

87

Function Test

The VideoJet X10 SN offers a variety of configuration options. You should therefore check that it is functioning correctly after installation and configuration.

The function test is the only way to ensure that the VideoJet X10 SN operates as expected in the event of an alarm.

Your check should include the following functions:

– Can the VideoJet X10 SN be called up remotely?

– Does the VideoJet X10 SN transmit all the required data?

– Does the VideoJet X10 SN respond to alarm events as required?

– Do the recordings occur as intended?

– Is it possible to control peripherals if necessary?

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

88

en | Configuration Using a Web Browser VideoJet X10 SN

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

6

6.1

i

Operation | en

89

Operation

Operation with Microsoft Internet Explorer

A computer with Microsoft Internet Explorer (version 6.0 or higher) can receive live images from the VideoJet X10 SN, control cameras or other peripherals and replay stored video sequences.

System Requirements

– Computer with Windows XP or Windows Vista operating system

– Network access (Intranet or Internet)

– Microsoft Internet Explorer (version 6.0 or higher)

– Screen resolution 1,024 × 768 pixels

– 16- or 32-bit color depth

– Installed Sun JVM

– For playing back recordings: connection to storage medium

NOTICE!

Also note the information in the System Requirements document on the product CD supplied. If necessary, you can install the required programs and controls from the product

CD supplied (see Section 3.1 Scope of Delivery, page 11).

The Web browser must be configured to enable Cookies to be set from the IP address of the unit.

In Windows Vista, deactivate protected mode on the Security tab under Internet Options.

You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer.

Installing MPEG ActiveX

Suitable MPEG ActiveX software must be installed on the computer to allow the live video images to be played back. If necessary, you can install the program from the product CD supplied.

1.

Insert the product CD into the computer's CD-ROM drive. If the CD does not start automatically, open the root directory of the CD in Windows Explorer and double-click

MPEGAx.exe.

2.

Follow the on-screen instructions.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

90

en | Operation VideoJet X10 SN

Establishing the Connection

Before you can operate the VideoJet X10 SN within your network, it must have a valid IP address for your network and a compatible subnet mask.

The following default address is preset at the factory: 192.168.0.1

1.

Start the Web browser.

2.

Enter the IP address of the VideoJet X10 SN as the URL. The connection is established and after a short time you will see the LIVEPAGE with the video image.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

6.2

i

Operation | en

91

The LIVEPAGE

Once the connection is established, the Web browser displays the LIVEPAGE. It shows the live video image on the right of the browser window. Depending on the configuration, various

text overlays may be visible on the live video image (see Section 5.13 Advanced Mode: Display

Stamping, page 40).

Other information may be shown next to live video image on the LIVEPAGE. The display

depends on the settings on the LIVEPAGE Functions page (see Section 5.15 Advanced Mode:

LIVEPAGE Functions, page 42).

Maximum Number of Connections

If you do not connect, the unit may have reached its maximum number of connections.

Depending on the unit and network configuration, each VideoJet X10 SN can have up to 25

Web browser connections or up to 50 connections via VIDOS or Bosch Video Management

System.

Protected VideoJet X10 SN

If the VideoJet X10 SN is password protected against unauthorized access, the Web browser displays a corresponding message and prompts you to enter the password when you attempt to access protected areas.

NOTICE!

A VideoJet X10 SN offers the option to limit the extent of access using various authorization

levels (see Section 5.11 Advanced Mode: Password, page 38).

1.

Enter the user name and associated password in the corresponding text fields.

2.

Click OK. If the password is entered correctly, the Web browser displays the page that was called up.

Protected Network

If a RADIUS server is employed in the network for managing access rights (802.1x authentication), the VideoJet X10 SN must be configured accordingly, otherwise no

communication is possible (see Section Authentication, page 80).

Image Selection

You can view the image of the camera in different displays.

X

Click one of the tabs Stream 1, Stream 2 or M-JPEG below the video image to toggle between the different displays of the camera image.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

92

en | Operation VideoJet X10 SN

View Control

Control options for peripherals (for example a pan/tilt head or dome camera) depend on the type of unit installed and on the configuration of the VideoJet X10 SN.

If a controllable unit is configured and connected to the VideoJet X10 SN, the controls for the peripheral are displayed next to the video image.

1.

To control a peripheral, click the appropriate controls.

2.

Move the mouse cursor over the video image. Additional options for controlling peripherals are displayed with the mouse cursor.

Digital I/O

The alarm icons Input 1 to Input 4 are for information purposes and indicate the status of an alarm input: When an alarm is triggered, the corresponding icon lights up blue. The unit's configuration determines whether the alarm is displayed, as well as additional details (see

Section 5.15 Advanced Mode: LIVEPAGE Functions, page 42).

Triggering Relay

You can switch connected units using the relays in the VideoJet X10 SN (for example lights or door openers).

X

To activate this, click the icon for the corresponding relay next to the video image. The icon will be red when the relay is activated.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

Operation | en

93

VideoJet X10 SN

System Log / Event Log

i

The System Log field contains information about the operating status of the VideoJet X10 SN and the connection. You can save these messages automatically in a file (see

Section 5.15 Advanced Mode: LIVEPAGE Functions, page 42).

Events such as the triggering or end of alarms are shown in the Event Log field. You can save

these messages automatically in a file (see Section 5.15 Advanced Mode: LIVEPAGE Functions,

page 42).

1.

If you want to delete the entries, click the delete icon in the top right-hand corner of the relevant field.

2.

If you want to view a detailed log, click the icon in the top right-hand corner of the relevant field. A new window will open.

Audio Function

Depending on the configuration, the VideoJet X10 SN can send and receive audio signals. All users who are connected by browsers receive the audio signals sent by the VideoJet X10 SN.

Audio signals can only be sent to the VideoJet X10 SN by the user who connects to the unit first.

1.

On the LIVEPAGE, click anywhere next to the video image to remove the focus from the

ActiveX.

2.

Hold down the F12 key to make a voice connection to the VideoJet X10 SN. The browser's status bar displays the message Send Audio ON.

3.

Release the F12 key when you want to stop sending audio signals to the

VideoJet X10 SN. The status bar in Internet Explorer displays the message Send Audio

OFF.

NOTICE!

When the connection maintaining voice contact with the VideoJet X10 SN is broken, the next user to make a connection to the VideoJet X10 SN can send audio data to the

VideoJet X10 SN.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

94

en | Operation

6.3

VideoJet X10 SN

Saving Snapshots

You can save individual images from the video sequence currently shown on the LIVEPAGE in

JPEG format on your computer's hard drive. The icon for recording single images is only

visible if the unit is configured to enable this process (see Section Allow snapshots, page 43).

X

Click the icon. The image is saved at a resolution of 704 × 576 pixels (4CIF). The storage

location depends on the configuration of the VideoJet X10 SN (see Section Path for JPEG

and MPEG files, page 44).

6.4

Recording Video Sequences

You can save sections of the video sequence currently shown on the LIVEPAGE on your computer's hard drive. The icon for recording video sequences is only visible if the unit is

configured to enable this process (see Section Allow local recording, page 43).

1.

Click the icon to start recording. The storage location depends on the configuration of

the VideoJet X10 SN (see Section Path for JPEG and MPEG files, page 44). A red dot in the

icon indicates that recording is in progress.

6.5

i

2.

Click the icon again to stop recording.

NOTICE!

You can play back saved video sequences using the Player from Bosch Security Systems,

which can be installed from the product CD supplied (see Section 3.1 Scope of Delivery,

page 11).

Image Resolution

Sequences are saved at the resolution that has been preset in the configuration for the

encoder (see Section 5.19 Advanced Mode: Encoder Profile, page 46).

Running Recording Program

The hard drive icon below the camera images on the LIVEPAGE changes during an automatic recording.

A moving graphic will appear to indicate a running recording. If no recording is taking place, a static icon is displayed.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

6.6

Operation | en

95

The RECORDINGS Page

The RECORDINGS page for playing back recorded video sequences can be accessed from the

LIVEPAGE and from the SETTINGS menu.

The RECORDINGS link is only visible if a storage medium has been selected (see

Section 5.21 Advanced Mode: Storage Management, page 50).

X

Click the RECORDINGS link in the navigation bar in the upper section of the window. The playback page appears.

Camera

Here you can select the camera from which you want to view the recordings. Playback of the recordings starts immediately in the video window.

Recording

Here you can select the recording that you want to view. Playback of the recording starts immediately in the video window.

Controlling a Playback

Bosch Security Systems

You will see a time bar below the video image for quick orientation. A green arrow above the bar indicates the position of the image currently being played back within the sequence.

Installation and Operating Manual DOC | V4.0 | 2009.06

96

en | Operation VideoJet X10 SN

The time bar offers various options for navigation.

Red bars indicate the points in time where alarms were triggered. Drag the green arrow to navigate to these points quickly.

1.

You can change the time interval by clicking the zoom keys (magnifying glass icons). The display can span a range from two months to a few seconds.

2.

Drag the green arrow to the point in time at which playback should begin. The date and time display below the bar provides orientation to the second.

Buttons

You can control playback by means of the buttons below the video image. The buttons have the following functions:

Start or pause playback

Jump to the start of the active video sequence or to the previous sequence

Jump to the start of the next video sequence

Slide Control

You can use the slide control to control playback speed.

Bookmarks

In addition, you can set markers in the sequences, so-called bookmarks, and jump directly to these. These bookmarks are indicated as small yellow arrows above the time interval. Use the bookmarks as follows:

Jump to the previous bookmark

Set bookmark

Jump to the following bookmark

i

DOC | V4.0 | 2009.06

X

Right-click a bookmark to delete it.

NOTICE!

Bookmarks are only valid while you are in the RECORDINGS page; they are not saved with the sequences. As soon as you leave the page all bookmarks are deleted.

Trick Mode

If you are using a mouse with a scroll wheel, you can view recordings frame by frame in trick mode. To do this, place the mouse cursor in the timeline below the timescale and turn the scroll wheel. Playback is automatically stopped (paused) during scrolling. Trick mode requires

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

6.7

i

Operation | en

97

significantly higher memory capacity and computing power. For this reason, the number of cameras used in this mode can be restricted in the Configuration Manager program.

Installing the Player

You can play back saved video sequences using the Player from Bosch Security Systems,

which can be installed from the product CD supplied (see Section 3.1 Scope of Delivery,

page 11).

NOTICE!

In order to play back saved sequences using the Player, suitable MPEG ActiveX software must be installed on the computer.

1.

Insert the CD into the computer's CD-ROM drive. If the CD does not start automatically, open the CD in Windows Explorer and double-click the index.html file to start the menu.

2.

From the list field at the top, select the language you require and click Tools in the menu.

3.

Click the Archive Player option. The installation will start. Follow the instructions in the installation program. The Archive Player will be installed at the same time as the Player.

4.

After successful installation, you will find two new icons on your desktop for the Player and the Archive Player.

5.

Start the Player by double-clicking the Player icon.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

98

en | Operation

6.8

i i i

VideoJet X10 SN

Hardware Connections Between Video Servers

A VideoJet X10 SN with a camera connected to it can be used as a sender and a compatible

MPEG-4 hardware decoder (such as the VIP XD) with a connected monitor as a receiver using an Ethernet network connection. In this way it is possible to cover long distances without the need for major installation or cabling work.

NOTICE!

The sender and receiver must be located in the same subnet to establish a hardware connection.

Installation

Compatible video servers are designed to connect to one another automatically, provided they are correctly configured. They only need to be part of a closed network. Proceed as follows to install the units:

1.

Connect the units to the closed network using Ethernet cables.

2.

Connect them to the power supply.

NOTICE!

Make sure that the units are configured for the network environment and that the correct IP address for the remote location to be contacted in the event of an alarm is set on the Alarm

Connections configuration page (see Section 5.27 Advanced Mode: Alarm Connections,

page 58).

Connecting

There are three options for establishing a connection between a sender and a compatible receiver in a closed network:

– an alarm,

– a terminal program, or

– Internet Explorer.

NOTICE!

Connecting with a Web browser is described in the manual of the relevant unit that is to be used as the receiver, for example VIP XD.

Connecting on Alarm

With the appropriate configuration, a connection between a sender and a receiver is made

automatically when an alarm is triggered (see Section 5.27 Advanced Mode: Alarm Connections,

page 58). After a short time the live video image from the sender appears on the connected

monitor.

This option can also be used to connect a sender and a compatible receiver using a switch connected to the alarm input. You do not need a computer to make the connection in this case.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Operation | en

99

Connecting with a Terminal Program

Various requirements must be met in order to operate with a terminal program (see

Section 8.9 Communication with Terminal Program, page 110).

1.

Start the terminal program and enter the command 1 in the main menu to switch to the

IP menu.

2.

Enter the command 4 in the IP menu to change the remote IP address, then enter the IP address of the unit you wish to connect to.

3.

Enter the command 0 to return to the main menu and then enter the command 4 to switch to the Rcp+ menu.

4.

In the Rcp+ menu, enter the command 5 to activate the automatic connection.

Closing the Connection with a Terminal Program

1.

Start the terminal program and enter the command 4 in the main menu to switch to the

Rcp+ menu.

2.

In the Rcp+ menu, enter the command 5 to deactivate the automatic connection.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

100 en | Operation

6.9

VideoJet X10 SN

Operation Using Software Decoders

The VideoJet X10 SN video server combines with VIDOS to provide a high-performance system solution.

VIDOS is a software package for operating, controlling and managing CCTV installations (such as surveillance systems) at remote locations. It runs under Microsoft Windows operating systems. It is primarily designed for decoding video, audio and control data received from a remote sender.

Many options are provided for operation and configuration when using a VideoJet X10 SN with VIDOS. Please refer to the software documentation for more details.

Another program that supports the VideoJet X10 SN is Bosch Video Management System.

Bosch Video Management System is an IP video security solution that enables the seamless management of digital video, audio and data over any IP network. It was developed for use with Bosch CCTV products as one component of an extensive video security management system. It allows you to integrate your existing components into a simple-to-control system or into the entire Bosch range, benefiting from a complete security solution based on the latest technology and years of experience.

The VideoJet X10 SN video server is also designed for use with the DiBos 8 digital recorder.

DiBos 8 records up to 32 video and audio streams and is available as IP software or hybrid

DVR with additional analog camera and audio inputs. DiBos supports the most diverse functions on the VideoJet X10 SN video server, for example relay activation, remote control of peripherals and remote configuration. DiBos 8 can use the alarm inputs for event triggering and, on release of the MOTION+ motion detector, record the activated cells to enable intelligent motion search.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

7

7.1

7.2

i

!

Maintenance and Upgrades | en

101

Maintenance and Upgrades

Testing the Network Connection

You can use the ping command to check the connection between two IP addresses. This allows you to test whether a unit in the network is active.

1.

Open the DOS command prompt.

2.

Type ping followed by the IP address of the unit.

If the unit is found, the response appears as Reply from ... followed by the number of bytes sent and the transmission time in milliseconds. If not, the unit cannot be accessed over the network. This might be because:

– The unit is not correctly connected to the network. Check the cable connections in this case.

– The unit is not correctly integrated into the network. Check the IP address, subnet mask and gateway address.

Unit Reset

You can use the Factory Reset button to restore the unit to its original settings. Any changes to the settings are overwritten by the factory defaults. A reset may be necessary, for example, if the unit has invalid settings that prevent it from functioning as desired.

CAUTION!

All configured settings will be discarded during a reset.

If necessary, back up the current configuration using the Download button on the

Maintenance configuration page (see Section 5.43 Advanced Mode: Maintenance, page 84).

NOTICE!

After a reset, the unit can only be addressed via the factory default IP address. The IP address

can be changed as described in the Installation chapter (see Section 4.5 Setup Using the

Configuration Manager, page 24).

1.

If necessary, back up the current configuration using the Download button on the

Maintenance configuration page (see Section 5.43 Advanced Mode: Maintenance,

page 84).

2.

Using a pointed object, press the Factory Reset button located below the orange terminal

block until the Connect LED flashes red (see Section 3.4 Connections on the Front Panel,

page 16). All settings will revert to their defaults.

3.

Change the IP address of the VideoJet X10 SN if necessary.

4.

Configure the unit to meet your requirements.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

102 en | Maintenance and Upgrades

7.3

7.4

!

VideoJet X10 SN

Repairs

CAUTION!

Never open the housing of the VideoJet X10 SN.

The unit does not contain any user-serviceable parts.

Ensure that all maintenance or repair work is carried out only by qualified personnel

(electrical engineers or network technology specialists). In case of doubt, contact your dealer's technical service center.

Transfer and Disposal

The VideoJet X10 SN should only be passed on together with this installation and operating manual.

Your Bosch product is designed and manufactured with high-quality materials and components which can be recycled and reused.

This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.

In the European Union, there are separate collection systems for used electrical and electronic products. Please dispose of this equipment at your local community waste collection/recycling center.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

8

8.1

Appendix | en

103

Appendix

Troubleshooting

If you are unable to resolve a malfunction, please contact your supplier or systems integrator, or go directly to Bosch Security Systems Customer Service.

You can view a range of information about your unit version on the System Overview page

(see Section 5.45 Advanced Mode: System Overview, page 86). Make a note of this information

before contacting Customer Service. You can download an internal maintenance log from the unit on the Maintenance page if you wish to send it to Customer Service by e-mail (see

Section Maintenance log, page 85).

The following tables are intended to help you identify the causes of malfunctions and correct them where possible.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

104 en | Appendix

8.2

VideoJet X10 SN

General Malfunctions

Malfunction

No connection between the unit and terminal program.

Possible causes

Incorrect cable connections.

Recommended solution

Check all cables, plugs, contacts, terminals and connections.

Check the other serial interface.

No image transmission to remote station.

No connection established, no image transmission.

The computer's serial interface is not connected.

Interface parameters do not match.

Camera error.

Faulty cable connections.

The unit's configuration.

Faulty installation.

Wrong IP address.

Faulty data transmission within the LAN.

The maximum number of connections has been reached.

If necessary select a different interface and make sure that the computer's interface parameters match those of the unit. Try the following standard parameters:

19,200 baud, 8 data bits, no parity, 1 stop bit. Next, disconnect the unit from the power supply and reconnect it again after a few seconds.

Connect local monitor to the camera and check the camera function.

Check all cables, plugs, contacts and connections.

Check all configuration parameters.

Check all cables, plugs, contacts and connections.

Check the IP addresses

(terminal program).

Check the data transmission with ping.

Wait until there is a free connection and then call the sender again.

No audio transmission to Hardware fault.

remote station.

Faulty cable connections.

Incorrect configuration.

The audio voice connection is already in use by another receiver.

Check that all connected audio units are operating correctly.

Check all cables, plugs, contacts and connections.

Check audio parameters on the

Audio configuration and

LIVEPAGE Functions pages.

Wait until the connection is free and then call the sender again.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Appendix | en

105

Malfunction

The unit does not report an alarm.

Control of cameras or other units is not possible.

The unit is not operational after a firmware upload.

Placeholder with a red cross instead of the

ActiveX components.

Web browser contains empty fields.

Possible causes

Alarm source is not selected.

No alarm response specified.

Recommended solution

Select possible alarm sources on the Alarm Inputs configuration page.

Specify the desired alarm response on the Alarm

Connections configuration page,

change the IP address if necessary.

The cable connection between the serial interface and the connected unit is not correct.

The interface parameters do not Make sure that the settings of all match those of the other unit connected.

units involved are compatible.

Power failure during programming by firmware file.

Check all cable connections and ensure all plugs are properly fitted.

Incorrect firmware file.

JVM not installed on your computer or not activated.

Have the unit checked by

Customer Service and replace if necessary.

Enter the IP address of the unit followed by /main.htm in your

Web browser and repeat the upload.

Install Sun JVM from the product CD.

Active proxy server in network.

Create a rule in the local computer's proxy settings to exclude local IP addresses.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

106 en | Appendix

8.3

VideoJet X10 SN

Malfunctions with iSCSI Connections

Malfunction

After connecting to the iSCSI destination, no

LUNs are displayed.

After connecting to the iSCSI destination, "LUN

FAIL" appears below a node.

LUN mapping is not possible.

Possible causes

Incorrect LUN mapping during iSCSI system configuration.

Recommended solution

Check the iSCSI system configuration and reconnect.

The LUN list could not be read, as it was assigned to the wrong network interface.

Check the iSCSI system configuration and reconnect.

Some iSCSI systems do not support the use of an initiator extension.

Delete the initiator extension on the Identification configuration page.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

8.4

Appendix | en

107

LEDs

The VideoJet X10 SN network video server has a number of LEDs on its front and rear panels that show the operating status and can give indications of possible malfunctions:

ETH LED

Does not light up:

Lights up yellow:

Flashes yellow:

Connect LED

Lights up red:

Lights up green:

Flashes green:

Flashes red:

No network connection.

Network connection established.

Data being transmitted over the network.

Startup in progress.

Startup complete, VideoJet X10 SN is operational.

Video connection established.

VideoJet X10 SN is faulty, for example following failed firmware upload.

CF LED

Flashes orange: Activity on CF card.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

108 en | Appendix

8.5

VideoJet X10 SN

Processor Load

If the VideoJet X10 SN is accessed via the Web browser, you will see the processor load indicator in the top right of the window next to the manufacturer's logo.

8.6

8.7

You can obtain additional information to help you when troubleshooting or fine tuning the unit. The values indicate the proportions of the individual functions on the encoder load, shown as percentages. The JPEG parameter relates to snapshots and M-JPEG. The scaler converts the input format 4CIF to the other formats configured.

1.

Move the cursor over the graphic indicator. Some additional numerical values are also displayed.

2.

Click the graphic indicator. Further details are displayed.

Network Connection

You can display information about the network connection. To do this, move the cursor over the i icon.

Link

UL

DL

Ethernet link type

Uplink, speed of the outgoing data traffic

Downlink, speed of the incoming data traffic

Serial Interface

Options for using the serial interface include transferring transparent data, controlling connected units or operating the unit with a terminal program.

The serial interface supports the RS-232, RS-422 and RS-485 transmission standards. The

mode used depends on the current configuration (see Section 5.37 Advanced Mode: COM1,

page 75). Connection is via the terminal block.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

8.8

Appendix | en

109

Terminal Block

The terminal block has several contacts for:

– 4 alarm inputs

– 4 relay outputs

– Serial data transmission

Pin Assignment

The pin assignment of the serial interface depends on the interface mode used (see

Section 5.37 Advanced Mode: COM1, page 75).

Contact

CTS

TXD

RTS

RXD

GND

RS-232 mode

CTS (clear to send)

TxD (transmit data)

RTS (ready to send)

RxD (receive data)

GND (ground)

RS-422 mode

RxD- (receive data minus)

TxD- (transmit data minus)

TxD+ (transmit data plus)

RxD+ (receive data plus)

RS-485 mode

Data-

Data+

+

RM1

RM2

BP

GND

R2

R3

R4

Contact

IN1

IN2

IN3

IN4

GND

R1

Function

Input alarm 1

Input alarm 2

Input alarm 3

Input alarm 4

Ground

Relay output 1

Relay output 2

Relay output 3

Relay output 4

LED remote indicator

LED remote indicator

Backup power supply

Ground

10 to 30 V (power supply)

Ground

Connect each alarm input to a ground contact (GND) when connecting alarm inputs.

For the RM1 and RM2 contact specifications, see Section Remote Indication of the Connection

Status, page 22.

For the backup power supply specifications, see Section Backup Power Supply, page 23.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

110 en | Appendix

8.9

i

VideoJet X10 SN

Communication with Terminal Program

Data Terminal

If a VideoJet X10 SN cannot be found in the network or the connection to the network is interrupted, you can connect a data terminal to the VideoJet X10 SN for initial setup and setting of important parameters. The data terminal consists of a computer with a terminal program.

You require a serial transmission cable with a 9-pin Sub-D plug to connect to the computer

and open ends for connection to the terminal block of the VideoJet X10 SN (see Section Pin

Assignment, page 109).

HyperTerminal, a communications accessory included with Microsoft Windows, can be used as the terminal program.

NOTICE!

Information on installing and using HyperTerminal can be found in the manuals or in the online help for Microsoft Windows.

1.

Disconnect the VideoJet X10 SN from the Ethernet network before working with the terminal program.

2.

Connect the serial interface of the VideoJet X10 SN using any available serial interface on the computer.

Configuring the Terminal

Before the terminal program can communicate with the VideoJet X10 SN, the transmission parameters must be matched. Make the following settings for the terminal program:

– 19,200 bps

– 8 data bits

– No parity check

– 1 stop bit

– No protocol

Command Inputs

After the connection has been established, you must log on to the VideoJet X10 SN to access the main menu. Other submenus and functions can be accessed using the on-screen commands.

1.

If necessary, turn off the local echo so that entered values are not repeated on the display.

2.

Enter one command at a time.

3.

When you have entered a value, such as the IP address, check the characters you have entered before pressing Enter to transfer the values to the VideoJet X10 SN.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Appendix | en

111

Assigning an IP Address

Before you can operate a VideoJet X10 SN in your network you must first assign it an IP address that is valid for your network.

The following default address is preset at the factory: 192.168.0.1

1.

Start a terminal program such as HyperTerminal.

2.

Enter the user name service. The terminal program displays the main menu.

3.

Enter command 1 to open the IP menu.

i

4.

Enter 1 again. The terminal program displays the current IP address and prompts you to enter a new IP address.

5.

Enter the desired IP address and press Enter. The terminal program displays the new IP address.

6.

Use the displayed commands for any additional settings you require.

NOTICE!

You must reboot to activate the new IP address, a new subnet mask or a gateway IP address.

Reboot

Briefly interrupt the power supply to the VideoJet X10 SN for a reboot (disconnect the power supply unit from the mains supply and switch on again after a few seconds).

Additional Parameters

You can use the terminal program to check other basic parameters and modify them where necessary. Use the on-screen commands in the various submenus to do this.

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

112 en | Appendix

8.10

VideoJet X10 SN

Copyrights

The firmware 4.0 uses the fonts "Adobe-Helvetica-Bold-R-Normal--24-240-75-75-P-138-

ISO10646-1" and "Adobe-Helvetica-Bold-R-Normal--12-120-75-75-P-70-ISO10646-1" under the following copyright:

Copyright 1984-1989, 1994 Adobe Systems Incorporated.

Copyright 1988, 1994 Digital Equipment Corporation.

Permission to use, copy, modify, distribute and sell this software and its documentation for any purpose and without fee is hereby granted, provided that the above copyright notices appear in all copies and that both those copyright notices and this permission notice appear in supporting documentation, and that the names of Adobe Systems and Digital Equipment

Corporation not be used in advertising or publicity pertaining to distribution of the software without specific, written prior permission.

This software is based in part on the work of the Independent JPEG Group.

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN

9

9.1

Specifications

Unit

Operating voltage

Power consumption

LAN interface

Data interfaces

CF slot

Alarm inputs

Relay outputs

Video input

Audio input (Line In)

Audio output (Line Out)

Displays

Thermal value

Operating conditions

Approvals

Dimensions (H × W × D)

Weight

Specifications | en

113

10 to 30 V DC, power supply via external unit

Approx. 11 W with full equipment

1 × Ethernet 10/100 Base-T, automatic adjustment, half/full duplex, RJ45

1 × RS-232/RS-422/RS-485, bidirectional, push-in terminal

1 × USB 2.0, 2.5 W max.

1 × CompactFlash type I and II, for standard CF cards

4 × push-in terminals (non-isolated closing contact), maximum activation resistance 10 Ohm

4 × push-in terminal, 30 V p-p

, 2 A (SELV), 8 contacts

1 × BNC socket

0.7 to 1.2 V p-p

, 75 Ohm, PAL/NTSC

1 × 3.5 mm stereo socket

5.5 V p-p

max., impedance 9 kOhm typ.

1 × 3.5 mm stereo socket,

3.0 V p-p

max. at impedance 10 kOhm typ.,

1.7 V p-p

max. at impedance 16 Ohm typ.

2 × LED (operating voltage/video connection, CF card) on the front panel,

1 × LED (network connection) on the rear panel

37 BTU/h with full equipment

Temperature: 0 to +50 °C / +32 to +122 °F relative humidity: 0 to 95%, non-condensing

IEC 60950; UL 60950; EN 50130-4; EN 50121-4; EN 55103-

1; EN 55022; EN 55024; EN 61000-3-2; EN 61000-3-3;

FCC 47 CFR Chapter 1 Part 15

33 × 142 × 178 mm / 1.3 × 5.6 × 7.0 in, including BNC connections

Approx. 0.6 kg / 1.3 lb

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

114 en | Specifications

9.2

VideoJet X10 SN

Protocols/Standards

Video standards

Video coding protocols

PAL, NTSC

H.264 Baseline Profile, MPEG-4, M-JPEG, JPEG

Video data rate 9.6 kbps to 6 Mbps

Image resolutions (PAL/NTSC) 704 × 576/480 pixels (4CIF/D1)

704 × 288/240 pixels (2CIF)

464 × 576/480 pixels (2/3 D1)

352 × 576/480 pixels (1/2 D1)

352 × 288/240 pixels (CIF)

176 × 144/120 pixels (QCIF)

Total delay 120 ms (PAL/NTSC, MPEG-4, no network delay)

Image refresh rate

Network protocols

25/30 ips max.

RTP, Telnet, UDP, TCP, IP, HTTP, HTTPS, DHCP, IGMP V2,

IGMP V3, ICMP, RTSP, FTP, ARP, SNTP, SNMP (V1, MIB-II),

802.1x

Audio coding protocol

Audio sampling rate

Audio data rate

G.711, 300 Hz to 3.4 kHz

8 kHz

80 kbps

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Glossary | en

115

10 Glossary

Symbols

10/100/1000 Base-T IEEE-802.3 specification for 10, 100 or 1000 Mbps Ethernet

802.1x

The IEEE 802.1x standard provides a general method for authentication and authorization in

IEEE-802 networks. Authentication is carried out via the authenticator, which checks the transmitted authentication information using an authentication server (see RADIUS server) and approves or denies access to the offered services (LAN, VLAN or WLAN) accordingly.

ARP

A

Address Resolution Protocol: a protocol for mapping MAC and IP addresses

Baud bps

BVIP

CF

CIF

B

Unit of measurement for the speed of data transmission

Bits per second, the actual data rate

Bosch Video over IP unit

C

CompactFlash; interface standard, for digital storage media amongst other things. Used in computers in the form of CF cards, digital cameras and Personal Digital Assistants (PDA).

Common Intermediate Format, video format with 352 × 288/240 pixels

DHCP

DNS

DynDNS

FTP

Full duplex

GBIC

GOP

D

Dynamic Host Configuration Protocol: uses an appropriate server to enable dynamic assignment of an IP address and other configuration parameters to computers on a network

(Internet or LAN).

Domain Name System, mainly used for converting domain names to IP addresses

DNS hosting service that works according to RFC 2845 and stores the IP addresses of its clients in a database, ready for use

F

File Transfer Protocol

Simultaneous data transmission in both directions (sending and receiving)

G

GigaBit Interface Converter; applied in network technology to render interfaces flexible, for converting an electrical interface into an optical interface, for example. This enables flexible operation of an interface as a Gigabit Ethernet via twisted-pair cables or fiber optic cables.

Group of Pictures

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

116 en | Glossary VideoJet X10 SN

HTTP

HTTPS

MAC

MIB

MPEG-2

H

Hypertext Transfer Protocol: protocol for transmitting data over a network

Hypertext Transfer Protocol Secure: encrypts and authenticates communication between Web server and browser

ICMP

ID

IEEE

IGMP

Internet Protocol

IP

IP address iSCSI

ISDN

JPEG

I

Internet Control Message Protocol

Identification: a machine readable character string

Institute of Electrical and Electronics Engineers

Internet Group Management Protocol

The main protocol used on the Internet, normally in conjunction with the Transfer Control

Protocol (TCP): TCP/IP

See Internet Protocol

A 4-byte number uniquely defining each unit on the Internet. It is usually written in dotted decimal notation, for example "209.130.2.193".

Storage over IP process for storage networks; specifies how storage protocols are operated over IP

Integrated Services Digital Network

J

An encoding process for still images (Joint Photographic Experts Group) kbps

K

Kilobits per second, the actual data rate

L

LAN See Local Area Network

Local Area Network A communications network serving users within a limited geographical area such as a building or university campus. It is controlled by a network operating system and uses a transfer protocol.

LUN Logical Unit Number; logical drive in iSCSI storage systems

M

Media Access Control

Management Information Base; a collection of information for remote servicing using the

SNMP protocol

Improved video/audio compression standard, compression on highest level allows images in studio quality; now established as broadcast standard

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Glossary | en

117

MPEG-4

MSS

Net mask

NTP

OF

Parameters

A further development of MPEG-2 designed for transmitting audiovisual data at very low transfer rates (for example over the Internet)

Maximum Segment Size; maximum byte figure for the user data in a data packet

N

A mask that explains which part of an IP address is the network address and which part is the host address. It is usually written in dotted decimal notation, for example "255.255.255.192".

Network Time Protocol; a standard for synchronizing computer system clocks via packetbased communication networks. NTP uses the connectionless network protocol UDP. This was developed specifically for enabling time to be reliably transmitted over networks with variable packet runtime (Ping).

O

Optical Fiber; now used predominantly as the transmission medium for line-borne telecommunication processes (glass fiber cable)

P

Values used for configuration

Q

Quarter CIF, video format with 176 × 144/120 pixels QCIF

RADIUS server

RFC 868

RS-232/-422/-485

RTP

RTSP

SFP

SNIA

SNMP

R

Remote Authentication Dial-In User Service: a client/server protocol for the authentication, authorization and accounting of users with dial-up connections on a computer network.

RADIUS is the de-facto standard for central authentication of dial-up connections via Modem,

ISDN, VPN, Wireless LAN (see 802.1x) and DSL.

A protocol for synchronizing computer clocks over the Internet

Standards for serial data transmission

Real-Time Transport Protocol; a transmission protocol for real-time video and audio

Real-Time Streaming Protocol; network protocol for controlling the continuous transmission of audiovisual data (streams) or software over IP-based networks

S

Small Form-factor Pluggable; small, standardized module for network connections, designed as a plug connector for high-speed network connections

Storage Networking Industry Association; association of companies for defining the iSCSI standard

Simple Network Management Protocol; a protocol for network management, for managing and monitoring network components

Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

118 en | Glossary VideoJet X10 SN

SNTP

SSL

Subnet mask

TCP

Telnet

TLS

Simple Network Time Protocol; a simplified version of NTP (see NTP)

Secure Sockets Layer; an encryption protocol for data transmission in IP-based networks

See Net mask

T

Transmission Control Protocol

Login protocol with which users can access a remote computer (Host) on the Internet

Transport Layer Security; TLS 1.0 and 1.1 are the standard advanced developments of SSL 3.0

(see SSL)

Time-To-Live; life cycle of a data packet in station transfers TTL

U

UDP

URL

UTP

User Datagram Protocol

Uniform Resource Locator

Unshielded Twisted Pair

W

WAN See Wide Area Network

Wide Area Network A long distance link used to extend or connect remotely located local area networks

DOC | V4.0 | 2009.06

Installation and Operating Manual Bosch Security Systems

VideoJet X10 SN Index | de

119

11

Bosch Security Systems

Index

A

Activating the recording

57

Activation key

86

Alarm

17

,

41

,

92

Alarm e-mail

70

Alarm input

21

Alarm inputs

73

Alarm message

41

Alarm script

68

Alarm sensors

54

Audio connections

16

,

20

Audio input

16

Audio output

16

Audio settings

35

,

49

Audio stream on alarm

60

Audio transmission

35

,

43

,

49

Auto-connect

60

B

Basic mode

29

Baud rate

75

Bookmarks

96

Browser window

91

C

Camera

75

Camera name

31

,

37

Camera selection

91

Cameras

20

CF card

17

,

20

Changes

30

Changes in light level

63

Checking network

101

Closing contact

21

COM1

75

CompactFlash

17

,

20

Configuration

27

,

84

Configuration download

84

Configuration mode

29

Connect on alarm

58

Connecting

27

,

98

Contrast

45

Control

75

Control functions

92

Control signals

43

Controlling a playback

95

Conventions

7

D

Danger

9

Data bits

75

Data interface

21

Data terminal

110

Date

39

Date format

39

Daylight saving time

39

Default

48

,

54

,

61

,

62

Default profile

48

Deleting recordings

52

Device ID

36

Device name

31

,

36

DHCP server

33

Installations- und Bedienungshandbuch

Display stamping

40

Dome camera

21

Dual Streaming

13

,

46

DynDNS

78

E

Echo

110

Electromagnetic compatibility

8

E-mail

70

Encoder load

108

Encoding

13

Encryption protocol

77

EPROM

84

Establishing the connection

28

,

90

Event log

43

,

44

,

93

F

False alarms

63

Firewall

59

,

77

Firmware upload

84

Formatting

52

Front panel connections

16

FTP server

82

,

83

Function test

87

G

Gateway

33

,

77

General password

59

H

Holidays

57

,

67

HTTP port

77

HTTPS port

77

I

Identification

8

,

31

,

36

,

37

IEEE 802.1x

80

IGMP

81

Image quality

82

Image resolution

94

Image selection

91

Initiator name

37

Installation

9

Installation conditions

19

Installation location

19

Interface

108

Interface mode

75

Internal clock

39

IP address

33

,

77

,

111

iSCSI settings

51

J

JPEG image size

82

JPEG posting

82

JPEG posting interval

83

L

Language

41

Licenses

86

Live video images

27

,

89

Livepage

43

Low Voltage Directive

8

Low-pass filter

45

DOC | V4.0 | 2009.06

120 de | Index VideoJet X10 SN

DOC | V4.0 | 2009.06

M

Main functions

15

Maintenance

9

Manufacturer logo

41

Media-replay

95

Milliseconds

41

Motion detector

61

Motion detector defaults

61

,

62

Motion detector object size

64

Motion detector sensitivity

64

MPEG ActiveX

27

,

89

,

97

MTU value

77

,

78

Multicast address

81

Multicast connection

77

,

81

Multicast function

13

Multicasting

81

Multi-unicast

81

N

Navigation

30

Network

20

,

33

,

76

,

79

Network connection

17

,

24

,

108

Number of connections

28

,

91

O

Operation

9

,

89

Overview of functions

13

P

Parameters

25

,

111

Parity check

75

Password

29

,

31

,

32

,

38

,

91

Peripheral device control

92

Picture settings

45

Pin assignment

109

Playback

95

Playback button

96

Player

97

Port

77

,

82

Post-alarm profile

54

Post-alarm time

54

Power off

24

Power on

24

Power supply

9

,

17

,

24

Power switch

24

Pre-alarm time

54

Processor load

108

Processor load indicator

108

Product name

41

Profile configuration

47

Profiles

34

,

46

Protocol

75

R

RADIUS

80

Rear panel connections

17

Reboot

25

,

111

Receiver

13

Receiver password

59

Recording media

51

Recording profiles

53

Recording program

94

Recording scheduler

56

Recording status

57

Recording video sequences

94

Reflections of light

63

Regulations

7

Relay

17

,

22

Relay output

73

Relay outputs

22

Remote control

14

Remote indication

22

Remote LED

22

Repair

9

,

102

Reset

17

,

101

Router

82

S

Safety

9

Saturation

45

Saving event log

44

Saving system log

44

Scaler

108

Scope of delivery

11

Screen resolution

12

,

27

,

89

Select Area

65

Select area

64

,

65

Selecting a profile

46

Sensor fields

64

,

65

Serial interface

17

Serial number

8

Serial port function

75

Signal source

21

SMS

71

Snapshots

14

,

94

SNMP

80

SNTP server

33

,

40

Software decoder

100

Source type

44

SSL certificate

85

SSL encryption

60

Standard recording profile values

54

Stop bits

75

Storage media

51

Storage medium

35

,

50

Streaming

82

Subnet mask

33

,

77

Summer time

39

Symbols

7

Synchronize

32

,

39

System log

43

,

44

,

93

System requirements

12

,

27

,

89

T

Tamper detection

64

Target data rate

48

TCP

59

,

77

Terminal

75

Termination

44

Test

87

Time

23

,

32

,

39

,

40

Time server

32

,

40

Time server IP address

33

,

40

Time server protocol

32

,

40

Time signal

32

,

40

Time zone

39

TLS

77

Installations- und Bedienungshandbuch Bosch Security Systems

VideoJet X10 SN

Transmission parameters

110

Transmission protocol

59

,

77

Transmission rate

75

Transmission standards

21

,

108

Transparent

75

Traps

80

Trick mode

96

Trigger

21

Trigger relay

74

TTL

82

U

UDP

59

,

77

Unicast

81

Unit date

39

Unit identification

31

,

36

Unit name

31

,

36

Unit reset

101

Unit time

32

,

39

URL

28

,

90

USB interface

16

User name

31

,

38

V

Value

45

VCR

44

Video content analysis

61

Video input

44

Video sensor

61

VRM

50

W

Watermarking

41

Index | de

121

Bosch Security Systems Installations- und Bedienungshandbuch DOC | V4.0 | 2009.06

122 de | Index VideoJet X10 SN

DOC | V4.0 | 2009.06

Installations- und Bedienungshandbuch Bosch Security Systems

Bosch Sicherheitssysteme GmbH

Robert-Koch-Straße 100

85521 Ottobrunn

Germany

Telefon

Fax

089 6290-0

089 6290-1020

www.boschsecurity.com

© Bosch Sicherheitssysteme GmbH, 2009

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement