TCP/IP Alarm Control Panel Instruction Manual FC - E

TCP/IP Alarm Control Panel
Instruction Manual
FC-7540
P/N 2015070701-1
Wiring diagramme
LED dispaly Blink when GSM
on metal box work normal
Buzzer
CMS connect(quick blink)
disconnect(slow blink)
Battery
connecting
Microphone
Aux power
Siren
Power
Arm
Disarm
Fault
Enthernet
port
Power supply
Built-in 220AC transformer.
12V DC, 7AH battery.
Battery standby 16hours if connect one wired keypad(250MA power consumption)
Keypad, Aux power supply, siren etc power consumption can not exceed max power of FC-7540
Max recharge current of battery is 350MA
áÖ
²Ê
·ú
Ʋ
Brief
Thank you for purchasing the 'smart home'products of our company, we hope our
products can bring convenience and and protection for your safety!
The 'smart home' system uses the most advanced digital sensing and control
technology, it is a set of smart alarm control system of anti-theft,anti-fire, and
anti-gas leak compatible with wired and wireless alarm. This product is easy to
operate and easy to learn with voice indication all around the operation ,
complicated orders are not needed.
The 'smart home 'system recommends the most advanced multi-random vault
technology in safety and reliability, which effectively solve the problem of
interference, false positives, false negatives that cannot be solved by similar
system at present .The way the 'smart home' system uses in the alarm signal
on the common high-speed way CONTACT ID makes application of this series
of products wider and compatibility stronger. The system can be widely used in
family ,community,villas,shops,units and so on.
We recommend that you carefully read the instruction to facilitate you for a skilled
operation and use to the product, so the product can better serve you.
We will not notice if there is a change of product performance,
if you want to know the latest features,please contact with the
relevant business.
áÖ
²Ê
·ú
Ʋ
Product Introduction
Alarm Procedure
Voice Alarm Receiving And GSM Control
Remote Phone Control
Alarm receiving phone operation
GSM remote operation ( on-site Intercom added)
GSM Alarm Receiving (on-site intercom added)
GSM control via SMS
Keypad instruction
LED Display on metal box
System Arm And Disarm
Administrator programming
1.PASSWORD SETTING
1.1 Admin Password setting
1.2 User Password setting
2 CMS station setting
2.1 CMS phone # setting
2.2 CMS user ID setting
2.3 CMS dial times setting
2.4 User phone # settting
2.5 Dial times for User phone #
3. Network setting
3.1 Native IP setting
3.2 Network gateway setting
3.3 Network Mask setting.
3.4 Priority DNS
3.5 Backup DNS
3.6 CMS server IP
3.7 CMS server port
3.8 CMS registor IDExample
3.9 CMS resgitor PWD
3.10 CMS heartbeat time
4. System option setting
4.1 Entry delay
4.2 Exit delay
4.3 Siren time
4.4 Detector loss inspection time
4.5 AC off inspection time
1
2
3
3
3
4
4
4
5
6
7
8
9
9
9
9
9
10
10
10
10
11
11
11
11
11
12
12
12
12
13
13
13
13
13
14
14
14
áÖ
²Ê
·ú
Ʋ
4.6 Commnunication inspection Interval
4.7 Arm / disarm indication
4.8 Arm/disarm report
4.9 Set force arm
4.10 Magnetic contact inspection
4.11 Wireless detetor tamper inspection
4.12 Set zone alarm times
4.13 Panic (emergency) alarm siren type
4.14 system time set
5. Wireless device setting
5.1 Auto Code remote
5.2 Manual code remote
5.3 Auto code detector
5.4 Manual code detector
5.5 Code electronic switch
5.6 Code siren
5.7 Delete remote
5.8 Delete detector
5.9 Delete electronic swtich
5.10 Delete dual-way siren
6. Set system zone attribution
6.1 set zone attribution
6.2 set zone siren type
6.3 Set related zone
7. Other settings
7.1 Set timing arm/disarm operation
7.2 Recording
7.3 Play recording
7.4 Restore to factlry default
7.5 SMS language setting
7.6 Welcome mode setting
7.7 Network port setting
7.8 Network CMS connecting settings
Web IE Introduction
8.1 Remote Control
8.2 Password Setting
8.3 CMS Setting
8.4 Network Configuration
14
15
15
15
16
16
16
16
17
17
17
17
18
18
18
18
19
19
19
19
20
20
20
21
22
22
22
22
22
23
23
23
23
24
25
26
27
28
áÖ
²Ê
·ú
Ʋ
8.5 System Options
8.6 Voice phone settings
8.7 Wirless dvices
8.8 Zone configuration
8.9 System Event Log
8.10 Remote upgrade
8.11 System reboot
8.12 Alert setting
8.13 Email setting
8.14 Time setting
8.15 Home Automation setting
Technical specification
9.1 General data
Maintenance
10.1 Regular test
10.2 The cleanliness of control main machine
limitation of the products
29
30
30
31
32
33
34
34
35
36
37
37
37
37
38
38
38
áÖ
²Ê
·ú
Ʋ
Product Introduction
1. 40 zones total: 8 wired zone, 32 wireless zone.
2. 7 way to disarm system: password, remote controller, phone call, sms, web
server, schedule of timing disarm, CMS.
3. 8 LCD keypad, 8 remote controller, 16 channels electronic switch control.
4. 1 installer password, 16 user password.
5. 2 CMS phone number, 1 user code
6. 4 user phone number for remote control and receive alarm phone call.
7. 512 event log
8. Recording message: User can record 20sec alarm message.
1
áÖ
²Ê
·ú
Ʋ
Alarm Procedure
TELEPHONE
MOBILE PHONE
APP
SMS Remote Control
APP (Andriod/IOS)
IE Browse (ipad,
mobile, computer)
8
W
ire
d
Zo
ne
+1
SMS
EMAIL
32
CMS Alarm Center
CMS Software
2
Wi
rel
es
sZ
on
e
PG
M
Po
rt
áÖ
²Ê
·ú
Ʋ
Voice Alarm Receiving And GSM Control
Remote Phone Control
User make phone call to the GSM No. Of the alarm control panel. Directly connect to
the alarm control panel, according to the voice prompt to input the password as below
photo.
1.Dial the GSM No. Of the
alarm control panel.
2.The alarm control panel
auto off-hook
3.Please enter password
1234(default factory)
Press 1 to arm system
Press 2 to disarm system
Press 3 to Stay arm
Press 4 to check system
status
Press 5 to appliance switch
control
Press 9 to talk-back
Press0 to disconnect
Alarm receiving phone operation
When alarm, the panel will dial the pre-set voice phone number, when the user pick up
the call, they will hear the voice prompting as below, if not press 1 to cancel the alarm
or press 4 to disarm the system, after off-hook, the panel will call other preset voice
phone numbers .
1. The alarm control panel
dial preset voice phone as
soon as alarm occurs.
3.Play the recorded voice
message first.
Press 1 to cancel alarm
Press 2 to check alarm event
Press 3 to arm system
Press 4 to disarm system
Press 5 to stay arm
Press 6 to enable siren
Press 7 to listen in
Press 9 to talk-back
2. The user pick up the phone. Press 0 to disconnect
3
áÖ
²Ê
·ú
Ʋ
GSM remote operation ( on-site Intercom added)
When alarm occurs, GSM will call the preset voice number, when pick up the call, Enter
4 digit user code, then voice prompt:
Press 1 to arm system,
Press 2 to disarm system,
Press 3 to Stay arm,
Press 4 to check system status,
Press 5 to appliance switch control,
Press 9 to talk-back (Intercom function)
Press 0 to Disconnect.
GSM Alarm Receiving (on-site intercom added)
When alarm occurs, it will send SMS first, then call the preset voice number, when pick
up the call, it will play the recorded voice message first, then voice prompt:
Press 1 to cancel alarm,
Press 2 to check alarm event,
Press 3 to arm system,
Press 4 to disarm system,
Press 5 to Stay arm,
Press 6 to enable siren,
Press 7 to listen-in,
Press 9 to talk-back,
Press 0 to Disconnect.
GSM control via SMS
Arm Command
#PWD1234 # ARM
Disarm Command
#PWD1234 #DIS ARM
Home Arm Command
#PWD1234 # HOME
Status Checking command
#PWD1234 # CHECK
#PWD1234 # SWITCH OPEN XX(XX=01-16
on behalf of appliance switch number)
#PWD1234 # SWITCH CLOSE XX(XX=01-1
6 on behalf of appliance switch number)
Enable appliance switch command
Disable appliance switch command
Note:
1, the factory default user code is 1234, when arm successfully, SMS auto reply arm
successfully , if the password is correct, the command is not correct, SMS will reply
operation failure , if the password is not correct, no SMS reply.
2, 'FOR Enable/disable the appliance switch
#PWD1234 # SWITCH OPEN XX(01-16)
XX is for electric switch serial number from 01-16, there is space between OPEN
and XX
4
áÖ
²Ê
·ú
Ʋ
Keypad instruction
Power
Arm
Disarm
Fault
Power LED: Light on when both AC power and battery work , light off when both
not work. AC power work but battery abnormal, the LED slow blink.
Battery work but AC power abnormal, the led quick blink.
Fault led: Slow blink when communication fault, light off when without fault.
Arm LED: Light on when arm, slow blink when stay arm, quick blink when alarming.
Disarm LED:Light on when disarm, light off when zone fault.
Press and hold on fire button for 3seconds,
panel will alarming. During programming fire
button is UP key.
Press *+# to exit programming.
Press and hold on panic button for 3seconds,
panel will alarming. During programming panic
button is DOWN key.
Press # button to delete the wrong entering,
duringprogramming # button is confirm key.
Press and hold on emergency button for
3seconds,panel will alarming. During
programming emergency button is DEL key.
Press inquiry button to check event log,
During programming inquiry button is CONFIRM
key.
Common Operations
Default administrator PWD:012345
Default user PWD: 1234
ARM system: PWD[1234]+
Stay Aarm system:PWD[1234]+
Disarm system:PWD[1234]+
Bypass system:PWD[1234]+
+zone Number+
5
áÖ
²Ê
·ú
Ʋ
Enter programming: admin PWD[012345]+
Exit programing:
+[0]+
+
Lost Password Reset: During the first minute after power on, enter [000000]
+
+[0]+
you can enter the programing to reset admin PWD.
LED Display on metal box
Power LED: Light on when both AC power and battery work , light off when
both not work. AC power work but battery abnormal, the LED slow
blink. Battery work but AC power abnormal, the led quick blink.
Fault led: Light on when system fault.
Arm LED: Light on when arm, slow blink when stay arm.
Disarm LED:Light on when disarm, light off when zone fault.
Communication LED: Blink when communication fault.
Alarm LED: Blink when alarming.
Zone fault display:
Zone 8 alarming
Zone 8 fault
Zone 8 bypass
NOTE: It will keep display zone alarming after the first disarm operation.
Pls disarm one more time to update the LED display of system status.
6
áÖ
²Ê
·ú
Ʋ
System Arm And Disarm
Power
Arm
Power
Arm
Disarm
Fault
Disarm
Fault
M
D
Y
Press the arm key on remote or the
keypad, then you hear system armed,
please exit the protection area there
will be Di-Di sound to confirm the
system is armed successfully.
M
Arm
Power
Arm
Disarm
Fault
Disarm
Fault
D
Y
Press the key for home arm on the
remote or HOME key on the keypad,
then you will hear 'system stay' and it
display home arm icon on the LCD
screen.
Y
Press the disarm key on the remote
or enter your user password on the
keypad,then you will hear Di-Di and
voice 'system disarmed', then you
have disarm successfully.
Power
M
D
M
D
Y
Press the panic button on remote,
or press 3 key on panel for 3
seconds,it will trigger to alarm.
Note:
Above photo is arm/disarm by the remote controller.
Different way to arm/disarm, the CMS alarm center and SMS will
display the below code and let you know which ways to arm/disarm
the system.
7
Administrator programming
áÖ
²Ê
·ú
Ʋ
Administrator programming
Display
Programming address
Set data
Data bit count
Administrator menu and programming address:
01 Admin PWDsetting
02--16 user PWD setting
20-21 CMS phone # setting
22--CMS user ID setting
24-27 User phone # setting
28- user phone dial times setting
30- Native IP settings
31-Network gateway setting
32-Network Mask setting
33-Priority DNS
34-Backup DNS
35-CMS server IP
36-CMS server port
37-CMS registor ID
38-CMS resgitor PWD
39-CMS heartbeat time
40-Entry delay
41-Exit delay
42-Siren time
43-Detector loss inspection time
44-AC off inspection time
45-Commnunication inspection
Interval
46-Arm / disarm indication
47-Arm/disarm report
48-Forced arm
8
49-Magnetic contact open inspection
50-Wireless detector tamper
inspection
51-Limit of alarming times
52-Siren type of panic alarm
53-System clock setting
60-Enroll remote controller
61-Manual enter wireless code of
remote controller
62-Enroll detector
63-Manual enter wireless code of
detector
64-Enroll wireless electronic swtich
65-Enroll wireless siren
66-Delete remote controller
67-Delete detector
68-Delete wireless electronic switch
69-Delete dual-way wireless siren
70-Set zone type
71-Set zone siren type
72-Set related zone
80-Set timing operation
81-Record message
82-Play recorded message
83-Set back to factory default
84-Set language of SMS
85-Set welcome mode
86-Set network port
áÖ
²Ê
·ú
Ʋ
PASSWORD SETTING
1.PASSWORD SETTING
1.1Admin Password setting
EXAMPLE:Set Admin PWD as 112233(default is 012345)
Keypad
display
Programming Admin PWD
address
Keypad display
Press
to back to Standby interface
1.2User Password setting(dafault 1234)
Example:set the third user password as 5678
Keypad
display
Programming User PWD
address
Keypad display
Press
to back to Standby interface
NOTE: can set 15 user PWD in total, the programming address is 02-16
2 CMS station setting
2.1 CMS phone # setting
Example: set CMS phoner # as 80012345
Keypad
display
Programming
address
Phone #
Keypad display
Press
to back to Standby interface
NOTE: Can set 2 CMS phone # in total, address is from 20-21
9
CMS Setting
áÖ
²Ê
·ú
Ʋ
2.2 CMS user ID setting(default is 0000)
Example: Set CMS user ID as 6666
Keypad
display
Programming User ID
address
Keypad display
Press
to back to Standby interface
2.3 CMS dial times setting: set how many times will dial when the first dial is
failed.(default is 5 times)
Example: set dial times as 4
Keypad Programming Dial times
display address
Press
to back to Standby interface
2.4User phone # settting
Example: set the third user phone # as 93872105
Keypad Programming Phone number
display address
Press
to back to Standby interface
NOTE: Can set 4 user phone # in total, address is 24-27
2.5 Dial times for User phone #: how many times will dial when the alarming is
not canceled(default is 5)
Example :set dial time as 3
Keypad Programming Dial times
display address
Press
10
to back to Standby interface
áÖ
²Ê
·ú
Ʋ
Network setting
3. Network setting
3.1Native IP setting
Example: set native IP address as 192.168.211(default 192.168.1.81)
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
3.2-Network gateway setting (default192.168.1.1 )
Example: set network gaeway as 192.168.2.1
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
3.3Network Mask setting. (Set network mask as 255.255.255.0)
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
3.4 Priority DNS(default is 202.96.128.86) set as 202.96.128.85
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
11
áÖ
²Ê
·ú
Ʋ
Network setting
3.5 Backup DNS
Example: set Native backup DNS as009.009.009(default is 008.008.008)
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
3.6CMS server IP
Example: set CMS server IP as113.105.146.146(default is 0.0.0.0)
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
3.7CMS server port
Example: set CMS server port as01234(default is 07974)
Keypad Programming
display address
Port
Keypad display
Press
to back to Standby interface
3.8CMS registor IDExample: set CMS registor ID as55555555(default is 88888888)
Keypad
display
Programming
address
Keypad display
Press
12
to back to Standby interface
áÖ
²Ê
·ú
Ʋ
System option setting
3.9CMS resgitor PWD
Example: set CMS resgitor PWD as01234567(default is 00000000)
Keypad
display
Programming resgitor PWD
address
Keypad display
Press
to back to Standby interface
3.10CMS heartbeat time
Example: set CMS heartbeat time as789(default is 25)
Keypad Programming Time
display address
Keypad display
Press
to back to Standby interface
NOTE: Is better to keep the default setting, change the setting will easily cause
line-off. Connect to network CMS as priority, when network CMS trouble, then
connect to phone CMS.
4. System option setting
4.1Entry delay, the delay duration from trigger the delay zone and start
alarming(default is 10s)
Example:set entry delay as 15s
Keypad
display
Programming Time
address
Keypad display
Press
to back to Standby interface
4.2 Exit delay, the duration from user make the arm operation to system
enter arm status(default is 10s)
Example: Set Exit delay as 15s
Keypad
display
Programming Time
address
Keypad display
Press
to back to Standby interface
13
áÖ
²Ê
·ú
Ʋ
System option setting
4.3 Siren time(default is 5minutes)
Example:set siren time as 10minutes
Keypad
display
Programming Time
address
Keypad display
Press
to back to Standby interface
4.4 Detector loss inspection time(default 00, not detect)
Example: set Detector loss inspection time as 4 hours
Keypad
display
Programming Time
address
Keypad display
Press
to back to Standby interface
Note: Wireless detector send status signal to alarm panel every 3 hours. If the
panel does not receive detector's status signal during setted inspection time,
the panel will consider the detector loss.
Suggest to set wireless detector loss inspection timenot shorter than 4hours.
4.5AC off inspection time(default is 00, not insptect)
Example: set AC off inspection time as 4hours
Keypad
display
Programming Time
address
Keypad display
Press
to back to Standby interface
4.6Commnunication inspection Interval: the interval time of the communication
between alarm panel and CMS.
This is to check if the communication between the panel and cms is normal
(default 00 not inspect)
Example: set communication inspection interval as 15hours
14
áÖ
²Ê
·ú
Ʋ
System option setting
Keypad
display
Programming Time
address
Keypad display
Press
to back to Standby interface
4.7Arm / disarm indication: set of the siren give short sound when arm the system
on remote controller(default is mute).
1> sound 2> mute
Example: set the arm/disarm indication sound on.
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
4.8Arm/disarm report(dafault not report) 1> report 2> not report
Example: set arm/disarm report to CMS
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
4.9Set force arm: if enabel set force arm, when there is zone trouble, the system
can be armed and report the trouble zone s bypass message to CMS. If disable
the force arm, the system can not be armed(factory default is disable force arm)
1> Force arm 2> not arm
Example: enabel force arm
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
15
áÖ
²Ê
·ú
Ʋ
4.10 Magnetic contact inspection: Separate the magnetic strip from transmitter
will trigger the zone trouble(default is disable)
1> Enable 2> Disable
Example: Enable the Magnetic contact inspection
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
4.11Wireless detetor tamper inspection:If set enable the inspection, when
trigger the tamper of wireless detector will trigger alarm. If disable the
inspection, will not trigger alarm.
1> enbale 2> disable
Example: Disable the wireless detector tamper alarm inspection
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
4.12 Set zone alarm times: If set zone alarm times as 3, before cancel alarm or
disarm, continus trigger more than 3 time will not trigger the alarm on panel.
1> 3 times limited 2> no limited
Example: Set zone alarm 3 times
Keypad
display
Programming
address
Keypad display
Press
to back to Standby interface
4.13 Panic (emergency) alarm siren type: Set if the siren sound or not when
trigger Panic alarm on remote or emergency alarm on keypad.(default is mute)
1> pedal tone 2>Pulsed tone 3> mute
Example: set siren type as Continuous tone
16
áÖ
²Ê
·ú
Ʋ
Press
Wireless device setting
to back to Standby interface
4.14 system time set
Example: set system time as10:01:23 11/JULY/2015
Y M D H M S
Press
to back to Standby interface
5. Wireless device setting
5.1 Auto Code remote
Example: Auto code remote on the 5th position
Press
to back to Standby interface
5.2Manual code remote
Example: Manual code the remote 077230023
Press
to back to Standby interface
17
áÖ
²Ê
·ú
Ʋ
Wireless device setting
5.3 Auto code detector
Example:Auto code #9 detector
Keypad display
Keypad display
Trigger detector
Press
to back to Standby interface
5.4 Manual code detector
Example: Manual code #24 detector035126025
Keypad display
Press
Keypad display
to back to Standby interface
5.5 Code electronic switch
Example: Auto code #1 electronic swtich
Keypad display
Press
Is the 1st number of
Trigger electronic switch electronic switch s
9-digit code
to back to Standby interface
5.6 Code siren(Example: code dual way siren)
Keypad display
Press the SAVE
button on siren
Press
18
Is the 1st number of
siren s 9-digit code
to back to Standby interface
áÖ
²Ê
·ú
Ʋ
Wireless device setting
Note: When dua-way siren give tamper alarm, on the lcd screen on panel will
display zone 41. One panel can only code one pc of dualway siren. No limited
quantity on one-way siren.
5.7 Delete remote
Example:Delete the 8th remote
Keypad
display
Press
Programming
address
to back to Standby interface
Note: enter 0 to delete all remote
5.8 Delete detector
Example: Delete 11th detector
Keypad
display
Press
Programming
address
to back to Standby interface
Note: Enter 00 to delete all detectors
5.9 Delete electronic swtich
Example: Delete the #4 switch
Keypad
display
Press
Programming
address
to back to Standby interface
5.10 Delete dual-way siren
Keypad
display
Press
Programming
address
to back to Standby interface
Note: Deleted is dual-way siren
19
Set system zone attribution
áÖ
²Ê
·ú
Ʋ
6. Set system zone attribution
6.1 set zone attribution
The type of zone attributuion is as below
0)disable zone
1> delay zone
3>inerior zone
4>emergency zone
6>fire zone
7> key zone
2> perimeter zone
5> 24 hours zone
Interior zone only trigger alarm under system away-armed status.
Delay and perimeter zone trigger alarm under system stay-arm or away arm
status.
24 hours zone, emergency zone,fire zone will trigger alarmunder any
sysatem status
Factory default
wired zone 33-40 disable, wireless zone 1-32 enable,00 zone is system zone.
1-2 zone is delay zone, 3-32 is interior zone
Example: set the zone 30 as fire zone
Press
to back to Standby interface
Note: Enter zone # and press
Wiring of wired zone as below :
Resistors loop
N.C
button to check the zone type.
Resistors loop
N.O
6.2 set zone siren type(defaul is pedal tone )
the options as below
1>pedal tone 2> pulse tone 3> mute
Example: Set zone 33 siren type as pulse tone
20
Set system zone attribution
áÖ
²Ê
·ú
Ʋ
Press
to back to Standby interface
Note: enter zone # then press
to check the siren type
6.3 Set related zone:zone1+zone2+related time+mode
The options as below(default is disable)
Dual trigger mode: trigger zone1 or zone 2 will not tirgger alarm.
Trigger both zone 1 and zone 2 during the setted related time, will trigger alarm.
Example: set zone 5 and 9 as the 4th group
of dual trigger related zone. Related time is 100sec
Press
to back to Standby interface
21
Other settings
áÖ
²Ê
·ú
Ʋ
7. Other settings
7.1 Set timing arm/disarm operation
Example: Set #2 group of timing arm at10:00, disarm on 12:00
Press
to back to Standby interface
7.2 Recording
Press
to back to Standby interface
Note:Total 20sec to recording. The recording message
will display as soon as the panel dial the user phone #
7.3 Play recording
Play recording
Press
to back to Standby interface
7.4 Restore to factlry default
Press
22
to back to Standby interface
Other settings
áÖ
²Ê
·ú
Ʋ
7.5 SMS language setting
Options as below:0> Chinese 1> English
Example: Set SMS language as english
Press
to back to Standby interface
7.6 Welcome mode setting(default is disable)
Options as below 0> disable 1> ringing tone 2> welcome
Example: Set as welcome mode as welcome
Press
to back to Standby interface
Note: Under disarm status, the default setting of delay zone is welcome mode
of door bell zone
7.7 Network port setting(default is 00080). Example set network port as 00081
Press
to back to Standby interface
Note: Network prot can set as any 5-digit numbers from 00000 to 65535
7.8 Network CMS connecting settings. 0> disconnect 1> connect
Example: Set Connect the CMS network
Press
to back to Standby interface
23
áÖ
²Ê
·ú
Ʋ
Web IE Introduction
Open the IE browse and input the IP address of the alarm control panel,
please enter the user and password.
Default user account is admin, and password is 012345.
Open the internet browse as below photo.
24
áÖ
²Ê
·ú
Ʋ
8.1
Remote Control
Press the remote control icon to enter below interface.
System Status: including system arm, system disarm, system stay, cancel
alarm.
Zone Bypass: do not let the faulty zone without affecting the normal use of
other zones. User can bypass the faulty zone.
Zone: 1-40 for options
Bypass: Enable/Disable for options
After zone bypass enable success. User can check the bypass zones as below
photo.
25
áÖ
²Ê
·ú
Ʋ
8.2 Password Setting
Enter the password setting, including web admin, web user, panel user
password setting.
Press Save after setting, system will prompt"Data setting is saved",click
"Confirm" to complete the setting.
26
áÖ
²Ê
·ú
Ʋ
8.3 CMS Setting click icon
for CMS setting
8.3.1 CMS number setting
Enable CMS Phone click
to enable
Press SAVE key to complete the settings.
8.3.2 Network CMS settings
Enable Network CMS Click
to enable
Press SAVE key to complete the settings, prarameters only take effect
after reboot system
Note The Alarm info. Will only upload either CMS phone or Network CMS
If user enable both CMS phone and Network CMS, the alarm
information will upload to network CMS in priority and CMS phone will be
backup when network CMS failed.
27
áÖ
²Ê
·ú
Ʋ
8.4 Network Configuration click icon
for setting
7.4.1.Factory default 192.168.1.81.user need set IP according to local
IP settings, can not use the same IP for several alarm panels.
7.4.2.When set IPg
¡¢
a
te
¬
w
a
C
¡
yM
£
n
S
ed3
-d
¢
ig
i¬
t£fle
sth
a
n3
-d
ig
it,
u
e
s"0
"fo
re
p
la
e
cm
e
n
t
e
g
,ifo
yu
rIP
is1
¡
9
2
.1
6
8
.1
°.8
¡
1
o
yun
ed±
e
n
rtn
u
m
b
e
rlie
k1
¡
9
2
.°
1
6
8
.01
.0
8
1
¡
¡
±£
7
.4
.3
.P
e
s
ra
e
ve
kya
fte
ro
cm
p
le
tee
stin
g
sa
n
de
ixtm
e
n
u
.T
h
e
n
e
rb
ot
a
la
rm
p
a
n
e
ltoa
te
ke
fe
tc
28
áÖ
²Ê
·ú
Ʋ
8.5 System Options click icon
to system options settings
1.Entry delay is only for delay zones.
2.Exit delay time: User need exit within preset time after system armed.
3.Siren time: The alarm duration time after system alarm, default value:
5 minutes
4. Wireless detector loss time: If the panel doesn't receive status signal or
alarm signal within preset time, the panel will regard the detectors as loss.
5. AC off inspection time: When system AC power cut, user can set the delay
time to report to CMS, default value : 30minutes
6. Communicate test time: The interval test time between system and CMS,
default value: Disable
7.Arm/Disarm tone: user can enable/disable arm/disarm tone when arm/
disarm system via remote controller.
8.Arm/Disarm report User can enable/disable Arm/Disarm report to CMS,
default value is :disable.
9.Force arm: When enable force arm , System still can be force armed when
zones are in trouble and trouble zones will be bypassed automatically and
system will send bypass information to CMS. When disable force arm,
system can not be armed when zones are in trouble. Default value: Disable
10. Door contact inspection: When door/window is not well closed, the system
mochcm
e.natw
ei.Ö
p/¾
Í
Ë
h:¼
Ó
Ï
tøÐ
Þ
·Ê
É
°£ÐÃ
À
¹«²ºîÛ
¿
Æ
Ú
29
áÖ
²Ê
·ú
Ʋ
will receive zone trouble information from door contact if enable door contact
inpsection. Default value: Disable.
11.Wireless detector tamper: default value: enable
12., Zone alarm time:
If system is triggered more than once before system disarm or cancel alarm,
the system will not alarm if user set zone alarm time as 1.
8.6 Voice phone settings Click icon
User can set 4 voice numbers.
8.7 Wirless dvices Cick icon
to enter voice phone setting.
to enter wireless device settings
Remote controllers: NO.1-8 total 8 remote controllers
Wireless detector: NO.1-32 total 32 detectors
Wiresles appliance switch: NO.1-16 total 16 appliance swith
Note Wireless device enroll or delete data,for administrator only
30
áÖ
²Ê
·ú
Ʋ
8.8 Zone configuration: click icon
to enter zone settings
8.8.1 Zone type for ZONE NO.1-40
0>Disable
1>Delay zone
4>Emergency zone
2>Perimeter zone
5>24 hour zone
3>Burglar zone
6>Fire zone
7>Key zone
7.8.2 Set zone siren type£º
8.8.2 Set related zones NO.1-8
1.Pd
elapoint2.Pusl3
e.m
ute
Note
Key zone is only for Wired zones NO.33-40 only
31
áÖ
²Ê
·ú
Ʋ
8.9 System Event Log, click icon
to enter.
Note Please refer to page 31 to delete event logs
32
áÖ
²Ê
·ú
Ʋ
8.10
Remote upgrade, click icon
to enter setting
System application files / webpage upgrade: Click "Browse" will pop up a
page and then select
Load the document and click "Open" pop-up page will automatically shut down,
and then click "Submit" . Bottom of the page there will be a red strip and
percentage display during the upgrade process, the upgrade process
Do not close the page and turn off the power. The upgrade is complete and
then reboot the device.
33
áÖ
²Ê
·ú
Ʋ
8.11 System reboot click the icon
to to enter setting.
8.11.1 System reboot, click confirm to reboot system or click cancel to cancel
8.11.2 set back to factory default, click factory setting,click confirm to set
panel back to factory default.
8.12 Alert setting, click icon
set GPRS data.
34
to set 28 alert sending methods and
áÖ
²Ê
·ú
Ʋ
8.13 Email setting, click icon
to enter setting.
1.SMTP server setting, fill the SMTP server address.
2.SMTP port default is 25, do not support SSL Encrypted Port.
3.Please enter the email setting to enable the SMTP otherwisethe email
will not send mail.
hº£·Ö
¾
øÍ
Ë«¹Þϼ
Ð
Ó
Æ
¿²°À
ÃÐÊÚ
ÛîÉ tp:/w
.w
m
eiantech.com
35
áÖ
²Ê
·ú
Ʋ
8.14 Time setting, click icon
to enter setting.
1.The server can set example American National Standard Time
Service Center, time.nist.gov
2.Set four group timing arm/disarm time. The schedule of auto
arm/disarm sytem.
3.Please set the time follow the local time zone.
36
áÖ
²Ê
·ú
Ʋ
8.15 Home Automation setting:Click icon
To enter settings.
1.User can enroll electric swith to panel or enter wireless codes of electric
swither here.
2.Name the switch under switch location, set the time to turn on/off
under timing on/timing off.
Then click save.If want swtich on/off the switch immediate you can
choose on/off under ON/OFF.
The system can control 16 channels switch total.
37
áÖ
²Ê
·ú
Ʋ
Technical specification
General data.
Power supply: Built-in transformer Input 185-230VAC, Output 13VAC/2A
Can connect rechargeable battery:12V/7AH,Standby time 16hours
Frequency:433MHz/868MHz
Protocol with CMS: Ademco Contact ID
Signal transmit distance: 100 to 120 meters (open area)
The method of alarming dial: TCP/IP GSM or GPRS
Work temperature: 32F-120F
Storage temperature:-4F-140F
Humidity:85%, under 30
1.Operation temperature range: 0¡æ
~45¡
æ 32F
£ ¨~120F£©
2.Storage temperature range: -20¡æ
~60¡
æ -4F~140F
£¨
£©
3.Relative humidity:85% at 30¡
4.Color: as box indicated.
38
æ 86F
£¨
£©
áÖ
²Ê
·ú
Ʋ
Maintenance
Regular test
Design of components of the system is to reduce maintenance cost,
but still it is suggested that periodical check may be carried out.
The cleanliness of control main machine
Main control panel may be stained by fingers or covered by dust after
using for a while. Use soft cotton cloth or sponge to clean it, don't use
any lubricant, liquid such as kerosene, acetone and strong gel which
will damage appearance and the transparency of top window.
Attention: don't use any lubricant, liquid such as kerosene, acetone
and strong gel which will damage appearance and the top transparency
of window.
Limitation of the products
Although the products is a high standard products, there is also some
limitation of them such as false alarm or no alarm. The reasons may be
below:
Lack of maintenance, the system needs maintenance and test
regularly test the sensitive of the detector may decrease and the siren
may not whistle.Lack of power supply if no power input and the back up
power is not enough, the panel can not work normally.Telephone line
false, if the telephone line is cut, the panel could not send alarm signals.
Limitation of smoke detectors, if the smoke is far from the smoke
detector, the detector could not alarm.If the intrude break in through
some door or window not monitored. Or someone know how to make
the system not work.