SPECIFICATION MODULE NO.: EA TFT070

Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
SPECIFICATION
MODULE NO.:
EA TFT070-84ATP
APPROVED BY:
( FOR CUSTOMER USE ONLY )
PCB VERSION:
SALES BY
ISSUED DATE:
APPROVED BY
CHECKED BY
DATA:
PREPARED BY
2016/07/25
EA TFT070-84ATP
Page 1 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
Content
1.Summary
2.General Specification
3.Absolute Maximum Ratings
4.Electrical Characteristics
5.DC Characteristics
6.AC Characteristics
7.Optical Characteristics
8.Interface
9.Block Diagram
10.Reliability
11.Touch Panel Information
12.Contour Drawing
13.Other
EA TFT070-84ATP
Page 2 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
1.Summary
This technical specification applies to 7.0’ color TFT-LCD panel. The 7.0’ color TFT-LCD panel is
designed for camcorder, digital camera application and other electronic products which require high
quality flat panel displays. This module follows RoHS.
EA TFT070-84ATP
Page 3 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
2.General Specifications
Item
Dimension
Unit
Size
7.0
inch
Dot Matrix
800 x RGBx480(TFT)
dots
Module dimension
165.0(W) x 100(H) x 7.0(D)
mm
Active area
154.08 x 85.92
mm
Dot pitch
0.0642 x 0.179
mm
LCD type
TFT, Normally White, Transmissive
View Direction
12 o’clock
Gray Scale Inversion Direction 6 o’clock
Backlight Type
LED, Normally White
With /Without TP
With RTP
Surface
Anti-Glare
*Color tone slight changed by temperature and driving voltage.
EA TFT070-84ATP
Page 4 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
3.Absolute Maximum Ratings
Item
Symbol
Min
Typ
Max
Unit
Operating Temperature
TOP
-20
-
+70
℃
Storage Temperature
TST
-30
-
+80
℃
Note: Device is subject to be damaged permanently if stresses beyond those absolute maximum ratings
listed above
1. Temp. ≦60℃, 90% RH MAX. Temp.>60℃, Absolute humidity shall be less than 90% RH at 60℃
EA TFT070-84ATP
Page 5 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
4.Electrical Characteristics
4.1. Operating conditions:
Item
Symbol
Supply Voltage For Logic
VCC
Power Supply For Current
VCC =3.3V
Min
Typ
Max
Unit
Remark
3.0
3.3
3.6
V
Note 1
110
165
mA
Max.
1890
10.5
-
Unit
mA
mW
V
Hr
Remark
Note 1
Note 2,3,4
Note 1 : This value is test for Vcc=3.3V , Ta=25℃ only
4.2. LED driving conditions
Parameter
Symbol
LED current
Power Consumption
LED voltage
VLED+
LED Life Time
Note 1 : There are 1 Groups LED
Min.
1620
9.0
-
Typ.
180
50,000
Note 2 : Ta = 25 ℃
Note 3 : Brightness to be decreased to 50% of the initial value
Note 4 : The single LED lamp case
EA TFT070-84ATP
Page 6 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
5.DC CHARATERISTICS
Parameter
Symbol
Rating
Min
Typ
Max
Unit
Low level input voltage
VIL
0
-
0.3VCC
V
High level input voltage
VIH
0.7VCC
-
VCC
V
EA TFT070-84ATP
Condition
Page 7 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
6.AC CHARATERISTICS
6.1. AC Electrical Characteristics
Signal
HS setup time
HS hold time
VS setup time
VS hold time
Data setup time
Data hole time
VCC Power On Slew rate
RESET pulse width
DCLK cycle time
DCLK pulse duty
Symbol
Thst
Thhd
Tvst
Tvhd
Tdsu
Tdhd
TPOR
TRst
Tcoh
Tcwh
Min
8
8
8
8
8
8
1
20
40
Typ
50
Max
20
60
Unit
ns
ns
ns
ns
ns
ns
ms
ms
ns
%
6.2. Input Clock and Data Timing Diagram
EA TFT070-84ATP
Page 8 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
6.3. Timing
Item
Symbol
Min.
Values
Typ. Max.
Unit
CLK Frequency (DCLK)
fclk
26.4
33.3
46.8
MHz
Horizontal Display Area
thd
-
800
-
CLK
One Horizontal Line
th
862
1056
1200
CLK
thpw
1
-
40
CLK
HS Blanking
thb
46
46
46
CLK
HS Front Porch
thfp
16
210
354
CLK
Vertical Display Area
tvd
-
480
-
TH
VS period time
tv
510
525
650
TH
VS pulse width
tvpw
1
-
20
TH
VS Blanking
tvb
23
23
23
TH
VS Front Porch
tvfp
7
22
147
TH
HS pulse width
Remark
6.4. Data Input Format
Fig. Horizontal input timing diagram
Fig. Vertical input timing diagram
EA TFT070-84ATP
Page 9 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
http://www.lcd-module.de
info@lcd-module.de
7.Optical Characteristics
Item
Symbol
Tr
Tf
Response time
Contrast ratio
CR
Color Chromaticity
White
Viewing angle
(Gray Scale Inversion
Direction)
Hor.
Brightness
Ver.
Wx
Wy
ΘR
ΘL
ΦT
ΦB
-
Condition.
θ=0°、Φ=0°
At optimized
viewing angle
θ=0°、Φ=0
CR≧10
-
Min
-
Typ. Max.
10
20
15
30
Unit
.ms
.ms
400
500
-
-
Note 4
0.26
0.28
60
60
40
60
0.31
0.33
70
70
50
70
0.36
0.38
-
-
Note 2,5,6
240
320
-
Deg.
cd/m 2
Remark
Note 3
Note 1
Center of
display
Ta=25±2℃, IL=180mA
Note 1: Definition of viewing angle range
Fig. 8.1. Definition of viewing angle
Note 2: Test equipment setup:
After stabilizing and leaving the panel alone at a driven temperature for 10 minutes, the measurement
should be executed. Measurement should be executed in a stable, windless, and dark room. Optical
specifications are measured by Topcon BM-7orBM-5 luminance meter 1.0° field of view at a distance
of 50cm and normal direction.
EA TFT070-84ATP
Page 10 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
Fig. 8.2. Optical measurement system setup
EA TFT070-84ATP
Page 11 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
Note 3: Definition of Response time:
The response time is defined as the LCD optical switching time interval between “White” state and
“Black” state. Rise time, Tr, is the time between photo detector output intensity changed from 90%to
10%. And fall time, Tf, is the time between photo detector output intensity changed from 10%to 90%
D is p la y
D a ta
W h ite (T F T O F F )
B la c k (T F T O N )
W h ite (T F T O F F )
100%
90%
10%
0%
Note 4: Definition of contrast ratio:
The contrast ratio is defined as the following expression.
C on trast ratio (C R ) =
L u m in an ce m easu red w h en L C D on the "W hite" state
L u m in an ce m easu red w h en L C D o n the "B lack " state
Note 5: White Vi = Vi50 ± 1.5V
Black Vi = Vi50 ± 2.0V
“±” means that the analog input signal swings in phase with VCOM signal.
“±” means that the analog input signal swings out of phase with VCOM signal.
The 100% transmission is defined as the transmission of LCD panel when all the input terminals of
module are electrically opened.
Note 6: Definition of color chromaticity (CIE 1931)
Color coordinates measured at the center point of LCD
Note 7: Measured at the center area of the panel when all the input terminals of LCD panel are
electrically opened.
EA TFT070-84ATP
Page 12 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
8.Interface
8.1. LCM PIN Definition
Pin
Symbol
1
VLED2
VLED+
3
GND
4
VCC
5
R0
6
R1
7
R2
8
R3
9
R4
10
R5
11
R6
12
R7
13
G0
14
G1
15
G2
16
G3
17
G4
18
G5
19
G6
20
G7
21
B0
22
B1
23
B2
24
B3
25
B4
26
B5
27
B6
28
B7
29
GND
30
CLK
31
R/L
32
Hsync
33
Vsync
34
NC
35
U/D
36
RESET
37
NC
38
NC
39
NC
40
NC
Function
Backlight ground
Power supply for backlight
Power ground
Power for Digital Circuit
Red data(LSB)
Red data
Red data
Red data
Red data
Red data
Red data
Red data(MSB)
Green data(LSB)
Green data
Green data
Green data
Green data
Green data
Green data
Green data(MSB)
Blue data(LSB)
Blue data
Blue data
Blue data
Blue data
Blue data
Blue data
Blue data(MSB)
Power Ground
Sample clock
Right /Left selection
Horizontal Sync Input
Vertical Sync Input
No connection
Up/down selection
Global reset pin.
No connection
No connection
No connection
No connection
EA TFT070-84ATP
Remark
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
Note 2
Note 3,4
Note 3,4
Page 13 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
Note 1: When input 18 bits RGB data, the two low bits of R,G and B data must be grounded.
Note 2: Data shall be latched at the falling edge of CLK.
Note 3: Selection of scanning mode
Setting of scan
U/D
L
H
L
H
R/L
H
L
L
H
Scanning direction
Up to down, left to right
Down to up, right to left
Up to down, right to left
Down to up, left to right
Note 4: Definition of scanning direction.
Refer to the figure as below:
Up
Left
Right
Down
EA TFT070-84ATP
Page 14 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
http://www.lcd-module.de
info@lcd-module.de
9.Block Diagram
a
G 0~G7
B0~B7
Vsync,Hsync
RESET
VCC
R/L,U/D
INPUT CONNECTOR
R0~R7
TIM ING
C ON TR OLLER
SCAN DRIVER IC
CLK
TFT LCD
PANEL
DATA DRIVER IC
G ND
VLED+
VLED-
RTP Signal
LED CO NNECTOR
BACKLIG HT UNIT
XL,YU,XR,YD
R TP
EA TFT070-84ATP
Page 15 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
10.Reliability
Content of Reliability Test (Wide temperature, -20℃~70℃)
Environmental Test
Test Item
High Temperature
storage
Low Temperature
storage
High Temperature
Operation
Low Temperature
Operation
High Temperature/
Humidity Operation
Thermal shock
resistance
Content of Test
Endurance test applying the high storage
temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
Endurance test applying the electric stress
(Voltage & Current) and the thermal stress to the
element for a long time.
Endurance test applying the electric stress under
low temperature for a long time.
The module should be allowed to stand at 60
℃,90%RH max
The sample should be allowed stand the
following 10 cycles of operation
-20℃
25℃
70℃
Test Condition
80℃
200hrs
-30℃
200hrs
70℃
200hrs
Note
2
-20℃
200hrs
60℃,90%RH
96hrs
-20℃/70℃
10 cycles
1
——
1,2
——
30min
Vibration test
5min
30min
1 cycle
Endurance test applying the vibration during
transportation and using.
1,2
Total fixed
3
amplitude : 15mm
Vibration Frequency :
10~55Hz
One cycle 60 seconds
to 3 directions of
X,Y,Z for Each 15
minutes
Static electricity test Endurance test applying the electric stress to the VS=±600V(contact), ——
terminal.
±800v(air),
RS=330Ω
CS=150pF
10 times
Note1: No dew condensation to be observed.
Note2: The function test shall be conducted after 4 hours storage at the normal
Temperature and humidity after remove from the test chamber.
Note3: The packing have to including into the vibration testing.
EA TFT070-84ATP
Page 16 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
11.Touch Panel Information
EA TFT070-84ATP
ITO Glass 1.1mm
ITO G lass
CONTACT SIDE
STIFFENER
ITO Film
ITO Film 0.188mm
LO G IC
Page 17 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
11.1. Resistance Touch Panel General Specifications
Item
Description
Driving condition
DC3~7V
Operating force
30~80g
Linearity max
≤±1.5%
>10MΩ,25V(DC)
Insulating resistance
Light transparence
70%
Structure type
ITO Film/ITO Glass(F/G)
Surface Hardness
3H typ
Pen Hitting Durability
(with the silicon rubber)
>1000,000 times
X Axis resistance
Y Axis resistance
430~910Ω
150~530Ω
EA TFT070-84ATP
Page 18 of 19
Zeppelinstrasse 19
D-82205 Gilching
Fon +49-8105-778090
info@lcd-module.de
http://www.lcd-module.de
12.Contour Drawing
PIN
1
YU
2
XR
3
YD
The non-specified tolerance of dimension is
EA TFT070-84ATP
Page 19 of 19
4
XL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
0.3mm.
VLEDVLED+
GND
VCC
R0
R1
R2
R3
R4
R5
R6
R7
G0
G1
G2
G3
G4
G5
G6
G7
B0
B1
B2
B3
B4
B5
B6
B7
GND
CLK
R/L
Hsync
Vsync
DE
U/D
RESET
NC
NC
NC
NC
Download PDF