24ACC6
Performancet16 Air Conditioner
with Puronr Refrigerant
1---1/2 to 5 Tons
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 14 -- 16.5 SEER / 11.5-- 13.5 EER
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 72 dBA
S Compressor sound blanket standard
Comfort
S System supports Edger Thermidistatt or standard
thermostat controls
Reliability
S Puronr refrigerant -- environmentally sound, won’t
deplete the ozone layer and low lifetime servce cost.
the environmentally sound refrigerant
Carrier’s Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 24ACC has been designed utilizing Carrier’s
Puron refrigerant. The environmentally sound refrigerant allows
you to make a responsible decision in the protection of the earth’s
ozone layer.
This product has been designed and manufactured to meet
Energy Starr criteria for energy efficiency when matched with
appropriate coil components. Refer to the combination ratings in
the Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.
S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S Filter drier
S High and low pressure switches
S Balanced refrigeration system for maximum reliability
Durability
WeatherArmor Ultrat protection package:
S Solid, durable sheet metal construction
S Louvered coil guard
S Baked--on, complete outer coverage, powder paint
Applications
S Long--line -- up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
S
Low ambient
accessory kit
(down
to
--20_F/--28.9_C)) with
MODEL NUMBER NOMENCLATURE
1
N
2
N
3
A
4
A
5
A/N
6
N
7
N
8
N
9
A/N
10
A/N
11
A/N
12
N
13
N
2
4
A
C
C
6
3
6
A
0
0
3
0
Product
Series
Product
Family
Tier
Major
Series
SEER
Grille
Variations
Open
Open
Voltage
Series
24=AC
A=RES AC
C=Performance
C=Puron
6=16 SEER
A = Standard
0=Not
Defined
0=Not
Defined
3=208/230 ---1
24ACC6
the environmentally sound refrigerant
Cooling
Capacity
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
0=
Original
Series
This product has been designed and manufactured to
meet Energy Star® criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
STANDARD FEATURES
Feature
18
24
30
36
42
48
Puron Refrigerant
X
X
X
X
X
X
60
X
Maximum SEER *
16.0
16.0
16.5
16.5
16.0
16.0
16.0
Scroll Compressor
X
X
X
X
X
X
X
Field Installed Filter Drier
X
X
X
X
X
X
X
Front Seating Service Valves
X
X
X
X
X
X
X
Internal Pressure Relief Valve
X
X
X
X
X
X
X
Internal Thermal Overload
X
X
X
X
X
X
X
Long Line capability
X
X
X
X
X
X
X
Low Ambient capability with Kit
X
X
X
X
X
X
X
High Pressure Switch
X
X
X
X
X
X
X
Low Pressure Switch
X
X
X
X
X
X
X
Compressor Sound Blanket
X
X
X
X
X
X
X
Louvered Coil Guard
X
X
X
X
X
X
X
* With approved combinations
X = Standard
PHYSICAL DATA
UNIT SIZE --- VOLTAGE,
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
SERIES
Operating Weight lb (kg)
136 (61.7)
163 (73.9)
167 (75.7)
180 (81.6)
234 (106.1)
Shipping Weight lb (kg)
163 (73.9)
198 (89.8)
204 (92.5)
219 (99.3)
281 (127.5)
Compressor Type
Scroll
REFRIGERANT
Puron (R---410A)
Control
TXV (Puron Hard Shutoff)
Charge lb (kg)
4.60 (2.09)
6.00 (2.72)
6.81 (3.09)
7.00 (3.18)
8.62 (3.91)
COND FAN
Propeller Type, Direct Drive
Air Discharge
Vertical
Air Qty (CFM)
1881
2614
2614
3223
3810
Motor HP
1/12
1/10
1/10
1/12
1/5
Motor RPM
1100
800
800
800
800
COND COIL
Face Area (Sq ft)
11.50
15.10
17.20
17.60
25.15
Fins per In.
25
25
25
25
25
Rows
1
1
1
1
1
Circuits
3
4
4
4
6
VALVE CONNECT. (In. ID)
Vapor
3/4
3/4
3/4
7/8
7/8
Liquid
3/8
3/8
3/8
3/8
3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor*
3/4
7/8
Max Liquid Line
3/8
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other
Note: See unit Installation Instruction for proper installation.
{ See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.
2
48--- 30
60--- 30
248 (112.5)
291 (132.0)
337 (152.9)
372 (188.7)
10.50 (4.76)
14.50 (6.58)
4046
1/4
800
4046
1/4
800
20.10
20
2
7
30.15
20
2
8
7/8
3/8
7/8
3/8
1 1/8
sizes and lengths of lineset.
REFRIGERANT PIPING LENGTH LIMITATIONS
Liquid Line Sizing and Maximum Total Equivalent Lengths{ for Cooling Only Systems with Puronr Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and
outdoor units.
See Table below for liquid line sizing and maximum lengths :
Maximum Total Equivalent Length
Outdoor Unit BELOW Indoor Unit
18000
AC with
Puron
3/8
24000
AC with
Puron
3/8
30000
AC with
Puron
3/8
Liquid
Line
Diam.
w/ TXV
1/4
5/16
3/8
1/4
5/16
3/8
1/4
5/16
3/8
AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor
Vertical Separation ft (m)
0--- 5
(0--- 1.5)
6--- 10
(1.8--- 3.0)
11--- 20
(3.4--- 6.1)
21--- 30
(6.4--- 9.1)
31--- 40
(9.4--- 12.2)
41--- 50
(12.5--- 15.2)
51--- 60
(15.5--- 18.3)
61--- 70
(18.6--- 21.3)
71--- 80
(21.6--- 24.4)
150
250*
250*
75
250*
250*
30
175
250*
150
250*
250*
75
250*
250*
--- --225*
250*
125
250*
250*
75
250*
250*
--- --200
250*
100
250*
250*
50
250*
250*
--- --175
250*
100
250*
250*
50
250*
250*
--- --125
250*
75
250*
250*
--- --225*
250*
--- --100
250*
--- --250*
250*
--- --175
250*
--- --75
250*
--- --225*
250*
--- --125
250*
--- ----- --250*
--- --150
250*
--- --100
250*
--- ----- --250*
36000
5/16
175
150
150
100
AC with
3/8
3//8
250*
250*
250*
250*
Puron
42000
5/16
125
100
100
75
AC with
3/8
3/8
250*
250*
250*
250*
Puron
48000
AC with
3/8
3/8
250*
250*
250*
250*
Puron
60000
AC with
3/8
3/8
250*
250*
250*
225*
Puron
* Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line
--- --- = outside acceptable range
100
100
75
--- ---
--- ---
250*
250*
250*
250*
250*
75
50
--- ---
--- ---
--- ---
250*
250*
250*
250*
150
250*
250*
230
160
--- ---
190
150
110
--- ---
--- ---
Guideline for details.
Maximum Total Equivalent Length
Outdoor Unit ABOVE Indoor Unit
Size
Liquid Line
Connection
18000
AC with
Puron
3/8
24000
AC with
Puron
3/8
30000
AC with
Puron
3/8
Liquid
Line
Diam.
w/ TXV
1/4
5/16
3/8
1/4
5/16
3/8
1/4
5/16
3/8
AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor
Vertical Separation ft (m)
25
(7.6)
26--- 50
(7.9--- 15.2)
51--- 75
(15.5--- 22.9)
76--- 100
(23.2--- 30.5)
101--- 125
(30.8--- 38.1)
126--- 150
(38.4--- 45.7)
151--- 175
(46.0--- 53.3)
176--- 200
(53.6--- 61.0)
175
250*
250*
100
250*
250*
30
250*
250*
250*
250*
250*
125
250*
250*
--- --250*
250*
250*
250*
250*
175
250*
250*
--- --250*
250*
250*
250*
250*
200
250*
250*
--- --250*
250*
250*
250*
250*
225*
250*
250*
--- --250*
250*
250*
250*
250*
250*
250*
250*
--- --250*
250*
250*
250*
250*
250*
250*
250*
--- --250*
250*
250*
250*
250*
250*
250*
250*
--- --250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
250*
36000
5/16
225*
250*
250*
250*
250*
AC with
3/8
3/8
250*
250*
250*
250*
250*
Puron
42000
5/16
175
200
250*
250*
250*
AC with
3/8
3/8
250*
250*
250*
250*
250*
Puron
48000
AC with
3/8
3/8
250*
250*
250*
250*
250*
Puron
60000
3/8
3/8
250*
250*
250*
250*
250*
AC with
Puron
* Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
--- --- = outside acceptable range
3
24ACC6
Size
Liquid Line
Connection
REFRIGERANT CHARGE ADJUSTMENTS
Liquid Line Size
Puron Charge oz/ft
3/8
0.60
(Factory charge for lineset = 9 oz)
5/16
0.40
1/4
0.27
24ACC6
Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter
liquid lines, charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment
Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required?
Formula:
(.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment?
Formula:
(.40 oz/ft. x 45ft) – (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system
LONG LINE APPLICATIONS
An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable
refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line
depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.
For Air Conditioner systems, the chart below shows when an application is considered Long Line.
AC WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m)
Beyond these lengths, long line accessories are required
Liquid Line Size
1/4
Units On Same Level
No accessories needed within allowed
lengths
Outdoor Below Indoor
No accessories needed within allowed
lengths
Outdoor Above Indoor
175 (53.3)
5/16
120 (36.6)
50 (15.2)
120 (36.6)
3/8
80 (24.4)
35 (10.7)
80 (24.4)
Note: See Long Line Guideline for details
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for AC systems with Puron refrigerant:
Unit
Nominal
Size (Btuh)
18000
1 Stage
AC with
Puron
24000
1 Stage
AC with
Puron
30000
1 Stage
AC with
Puron
36000
1 Stage
AC with
Puron
42000
1 Stage
AC with
Puron
48000
1 Stage
AC with
Puron
60000
1 Stage
AC with
Puron
Maximum
Liquid Line
Diameters
(In. OD)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line
Diameters
(In. OD)
26--- 50
51--- 80
81--- 100
(7.9--- 15.2)
(15.5--- 24.4)
(24.7--- 30.5)
1/2
1
2
5/8
0
1
3/4
0
5/8
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
101--- 125
126--- 150
151--- 175
176--- 200
201--- 225
226--- 250
(30.8--- 38.1)
(38.4--- 45.7)
(46.0--- 53.3)
(53.6--- 61.0)
(61.3--- 68.6)
(68.9--- 76.2)
3
5
6
7
8
9
11
1
1
2
2
2
3
3
0
0
0
1
1
1
1
1
0
1
2
2
3
3
4
5
5
3/4
0
0
1
1
1
1
1
2
2
7/8
0
0
0
0
0
1
1
1
1
5/8
1
2
3
3
4
5
6
7
8
3/4
0
0
1
1
1
2
2
2
3
7/8
0
0
0
0
1
1
1
1
1
5/8
1
2
4
5
6
8
9
10
12
3/4
0
1
1
2
2
3
3
4
4
7/8
0
0
0
1
1
1
1
2
2
3/4
0
1
2
2
3
4
4
5
6
7/8
0
0
1
1
1
2
2
2
3
1 1/8
0
0
0
0
0
0
0
0
0
3/4
0
1
2
3
4
5
5
6
7
7/8
0
0
1
1
2
2
2
3
3
1 1/8
0
0
0
0
0
0
0
1
1
3/4
1
2
4
5
6
7
9
10
11
7/8
0
1
2
2
3
4
4
5
5
1 1/8
0
0
0
1
1
1
1
1
1
Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline.
4
ACCESSORY THERMOSTATS
PART NUMBER
PROGRAM
GAS
ELECTRIC
HEAT PUMP
HYBRID
HEAT
√
√
HEAT
COOL
√
3
1
2
1
√
3
1
2
1
Performance
TP---PRH01 ---A
TP---PAC01
7 ---Day
7 ---Day
TP---NRH01 ---A
TP---NAC01
NP
NP
√
√
√
√
√
√
√
√
THERMOSTAT ACCESSORIES
BRIEF DESCRIPTION
Indoor Remote Room Temperature Sensor
ExP Computer Programming Accessory
Thermostat Conversion Kit (4 to 5 wire) --- 10 pack
Large Decorative Backplate
Outdoor Air Temperature Sensor
PART NUMBER
SYSTXCCRRS01
TP---EXP01 ---A
TSTATXXCNV10‡
TX ---LBP01
TSTATXXSEN01 ---B*
THERMOSTATS USED WITH
All TP--- thermostats
TP---P thermostats
All Carrier branded thermostats
TP---Pxx, TP---Nxx, TC ---Pxx
All TP--- thermostats
KIT NUMBER
DESCRIPTION
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
48--- 30
60--- 30
KAAFT0101AAA
FREEZE THERMOSTAT
X
X
X
X
X
X
X
KAATD0101TDR
TIME DELAY RELAY
X
X
X
X
X
X
X
KSALA0301410
LOW AMBIENT PSW
X
X
X
X
X
X
X
KSALA0601AAA
MOTORMASTER 230V
X
X
X
X
X
X
X
HC32GE234
MOTOR FAN BALL BEARING
X
HC34GE240
MOTOR FAN BALL BEARING
X
X
HC32GE229
MOTOR FAN BALL BEARING
HC38GE228
MOTOR FAN BALL BEARING
HC40GE228
MOTOR FAN BALL BEARING
X
X
KSAHS1701AAA
HARD START (CAP/RELAY)
X
X
X
X
X
X
X
KSACY0101AAA
CYCLE PROTECTOR
X
X
X
X
X
X
X
KSASF0101AAA
SUPPORT FEET
X
X
X
X
X
X
X
KAACS0201PTC
START ASSIST PTC
X
X
X
X
X
X
X
KAALS0201LLS
LIQUID LINE SOLENOID
X
X
X
X
X
X
X
KAAWS0101AAA
WINTER START
X
X
X
X
X
X
X
KAACH1701AAA
CRANKCASE HTR
X
X
X
X
KAACH1601AAA
CRANKCASE HTR
X
S
S
KSATX0201PUR
TXV PURON HSO
X
X
X
KSATX0301PUR
TXV PURON HSO
KSATX0401PUR
TXV PURON HSO
KSATX0501PUR
TXV PURON HSO
X
X
X
X
X
X
{ Required accessories include ball bearing fan motor, compressor start assist (CAP / Relay), crankcase heater, evaporator freeze stat, hard shut---off TXV.
X = Accessory / S --- Standard
5
24ACC6
ACCESSORIES
ACCESSORY USAGE GUIDELINE
ACCESSORY
Ball Bearing Fan Motor
Compressor Start Assist Capacitor and Relay
Crankcase Heater
Evaporator Freeze Thermostat
Hard Shut---Off TXV
Liquid Line Solenoid Valve
Motor Master® Control or
Low---ambient Pressure Switch
Support Feet
Winter Start Control
Yes{
Yes
Yes
Yes
Yes
No
REQUIRED FOR LONG
LINE
APPLICATIONS*
(Over 80 ft./24.38 m)
No
Yes
Yes
No
Yes
No
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles/3.22 km)
No
No
No
No
Yes
No
Yes
No
No
Recommended
Yes
No
No
Recommended
No
REQUIRED FOR LOW---AMBIENT COOLING APPLICATIONS
(Below 55°F/12.8_C)
24ACC6
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline
Application Guideline.
{ Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control.
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMasterr is used.
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor
motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the
following applications:
Long line
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the
compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles.
Improves compressor lubrication on restart and minimizes the
chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
5. Cycle Protector
The cycle protector is designed to prevent compressor short
cycling. This control provides an approximate 5--minute delay
after power to the compressor has been interrupted for any
reason, including power outage, protector control trip, thermostat
jiggling, or normal cycling.
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation
when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.
7. Low--Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in
order to maintain head pressure within normal operating limits
(approximately 100 psig to 225 psig). The control will maintain
working head pressure at low--ambient temperatures down to 0_F
(--18_C) when properly installed.
Usage Guideline:
A Low--Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling operation is
used at outdoor temperatures below 55_F (12.8_C).
8. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --20_F (--28.9_C),
it maintains condensing temperature at 100_F ±10_F (37.8_C ±
5.5_C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or
Low--Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55_F (12.8_C).
Suggested for all commercial applications.
9. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also
is required to enable special thermostat features such as auxiliary
heat lock out.
Usage Guideline:
Suggested for all Carrier thermostats listed in this
publication.
6
Accessory Description and Usage (Listed Alphabetically) (Continued)
12. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
NOTE: Most indoor unit controls include this feature. For those
that do not, use the guideline below.
Usage Guideline:
For improved efficiency ratings for certain
combinations of indoor and outdoor units. Refer to
AHRI Unitary Directory.
13. Winter Start Control
This control is designed to alleviate nuisance opening of the
low--pressure switch by bypassing it for the first 3 minutes of
operation.
24ACC6
10. Support Feet
Four stick--on plastic feet that raise the unit 4 in. (101.6 mm)
above the mounting pad. This allows sand, dirt, and other debris
to be flushed from the unit base, minimizing corrosion.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
11. Thermostatic Expansion Valve (TXV)
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube.
Hard shut off types are available.
NOTE: When using a hard shut off TXV with single phase
reciprocating compressors, a Compressor Start Assist Capacitor
and Relay is required.
Usage Guideline:
Required to achieve AHRI ratings in certain equipment
combinations. Refer to combination ratings.
Hard shut off TXV or LLS required in air conditioner
long line applications.
Required for use on all zoning systems.
7
ELECTRICAL DATA
OPER VOLTS*
UNIT SIZE
FAN
V/PH
MCA
MAX
24ACC6
COMPR
MIN
LRA
RLA
FLA
MIN
WIRE
SIZE{
60° C
MIN
WIRE
SIZE{
75° C
MAX
LENGTH
ft. (m)}
60° C
MAX
LENGTH
ft. (m)}
75° C
MAX
FUSE**
or CKT
BRK
AMPS
20
25
25
30
40
40
40
18--- 30
48.0
9.0
0.50
11.8
14
14
67 (20.4) 64 (19.5)
24--- 30
58.3
13.5
0.70
17.6
14
14
46 (14.0) 43 (13..1)
30--- 30
64.0
12.8
0.70
16.7
14
14
44 (13.4) 41 (12.5)
36--- 30
208/230/1 ---60
253
197
77.0
14.1
0.50
18.1
12
12
57 (17.4) 54 (16.5)
42--- 30
112.0
17.9
1.20
23.6
10
10
85 (25.9) 81 (24.7)
48--- 30
109.0
19.9
1.20
26.1
10
10
70 (21.3) 67 (20.4)
60--- 30
135.0
21.4
1.20
28.0
8
10
91 (27.7) 56 (17.1)
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade
name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or 75_C insulation, copper
wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70).
}
Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2010 requirements of ASHRAE Standards 90.1
A--WEIGHTED SOUND POWER LEVEL (dBA)
Unit Size --Voltage, Series
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
48--- 30
60--- 30
Standard
Rating (dBA)
73
74
74
72
74
73
74
125
49.5
54.5
56.0
52.0
56.5
58.0
56.5
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
250
500
1000
2000
4000
58.5
64.5
69.0
63.0
59.5
62.0
67.0
71.5
66.0
62.0
62.5
66.0
68.5
64.5
61.0
61.0
64.0
66.0
61.0
58.5
61.5
65.0
66.5
63.5
61.0
61.0
65.0
66.0
62.0
58.0
62.5
66.5
68.0
63.0
59.5
NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- VOLTAGE, SERIES
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
48--- 30
60--- 30
REQUIRED SUBCOOLING _F (_C)
10 (5.6)
10 (5.6)
10 (5.6)
10 (5.6)
9 (5.0)
10 (5.6)
9 (5.0)
8
8000
52.4
53.0
53.5
51.5
56.5
51.0
51.5
9
0
0
0
0
0
24ACC630
24ACC636
24ACC642
24ACC648
24ACC660
O
O
O
O
O
O
O
O
O
O
O
O
O
O
FIELD CONTROL
SUPPLY CONN.
7/8" HOLE
O
X
O
O
O
O
O
O
208-230-1-60
X
X
X
X
X
X
230-1-60
3 1/2"
39 1/8"
32 5/16"
45 15/16"
35"
35"
35"
26" X 26"
31 1/2" X 31 1/2"
35" X 35"
28 5/16"
35"
18
24,30
36 THRU 60
32 5/16"
31 3/16"
UNIT SIZE
28 5/16"
X = YES
O = NO
28 11/16"
25 3/4"
B
31 3/16"
MINIMUM
MOUNTING PAD
DIMENSIONS
VAPOR
LINE CONN.
D
C
FIELD POWER SUPPLY CONN.
7/8" HOLE WITH
1 1/8" KNOCKOUT
0
24ACC624
B
0
24ACC618
ELECTRICAL
SERIES
A
CHARACTERISTICS
208/230-3-60
UNIT
DIMENSIONS -- ENGLISH
460-3-60
SQ.
7/8"
7/8"
7/8"
7/8"
3/4"
3/4"
3/4"
D
AIR DISCHARGE
A
3 7/8"
3 7/8"
3 7/8"
3 7/8"
3 3/4"
3 3/4"
3 3/4"
C
6 9/16"
6 9/16"
6 9/16"
6 9/16"
6 9/16"
6 9/16"
4 7/16"
E
G
P
9 1/8"
9 1/8"
9 1/8"
9 1/8"
9 1/8"
9 1/8"
7 13/16"
1 7/8"
28 7/16"
28 7/16"
28 7/16"
28 7/16"
24 11/16"
24 11/16"
21 1/4"
F
2 15/16"
2 15/16"
2 15/16"
2 15/16"
2 13/16"
2 13/16"
2 13/16"
K
3"
5/16"
17 7/8"
17"
18"
18 1/4"
16 1/2"
15 5/8"
13 1/4"
M
K
18 5/8"
17 1/2"
16"
16 7/8"
15"
15 1/2"
13 3/4"
N
P
G
372
291
281
219
204
198
163
36 1/8" X 39 5/16" X 49 9/16"
36 1/8" X 39 5/16" X 35 15/16"
36 1/8" X 39 5/16" X 42 3/4"
36 1/8" X 39 5/16" X 32 9/16"
32 3/8" X 35 1/2" X 35 15/16"
32 3/8" X 35 1/2" X 32 9/16"
26 7/8" X 30 1/16" X 32 9/16"
.
AIR IN
AIR IN
AIR
DISCHARGE
E
N
5. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED.
4. CENTER OF GRAVITY
F
2. MINIMUM OUTDOOR
AMBIENT IN COOLING
F, MAX. OPERATING
125
MODE IS 55
3. SERIES DESIGNATION IS THE 13TH POSITION OF THE
UNIT MODEL NUMBER.
1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT,
48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE,
AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
NOTES:
337
248
234
180
167
163
136
AIR IN
OPERATING SHIPPING
SHIPPING
WEIGHT (lbs)
WEIGHT (lbs)
DIMENSIONS (L x W x H)
24ACC6
M
20 1/4"
14"
17 1/2"
14"
14 3/4"
14"
12 3/4"
3/8" TIEDOWN KNOCKOUTS
(2) PLACES
L
AIR IN
5/8"
5/8"
5/8"
5/8"
1/2"
1/2"
1/2"
L
10
18
24,30
36 THRU 60
88.9
660.4 X 660.4
800.1 X 800.1
889.0 X 889.0
MINIMUM
MOUNTING PAD
DIMENSIONS
VAPOR
LINE CONN.
D
C
FIELD POWER SUPPLY CONN.
22.23 HOLE WITH
28.58 KNOCKOUT
UNIT SIZE
B
O
O
O
O
O
O
O
O
O
O
O
FIELD CONTROL
SUPPLY CONN.
22.23 HOLE
O
O
O
O
X
X
X
X
O
O
X = YES
O = NO
820.8
1166.8
889.0
0
24ACC660
889.0
0
24ACC648
993.8
889.0
0
24ACC642
719.2
889.0
0
24ACC636
820.8
X
208-230-1-60
O
792.2
0
24ACC630
230-1-60
O
719.2
O
O
728.7
X
X
792.2
0
24ACC624
654.0
0
24ACC618
B
ELECTRICAL
SERIES
A
CHARACTERISTICS
208/230-3-60
UNIT
DIMENSIONS -- SI
460-3-60
22.2
22.2
22.2
22.2
19.0
19.0
19.0
D
AIR DISCHARGE
ASQ.
98.6
98.6
98.6
98.6
95.2
95.2
95.2
C
166.7
166.7
166.7
166.7
166.7
166.7
112.7
E
722.3
722.3
722.3
722.3
627.1
627.1
539.8
F
47.6
231.8
231.8
231.8
231.8
231.8
231.8
198.4
G
P
74.6
74.6
74.6
74.6
71.4
71.4
71.4
K
76.2
8.0
454.0
431.8
457.2
463.6
419.1
396.9
336.6
M
K
473.1
444.5
406.4
428.6
381.0
393.7
349.3
N
G
M
9.53 TIEDOWN KNOCKOUTS
(2) PLACES
L
AIR IN
15.9
15.9
15.9
15.9
12.7
12.7
12.7
L
168.7
132.0
127.5
99.3
92.5
89.8
73.9
917.6 X 998.6 X 1173.2
917.6 X 998.6 X 912.8
917.6 X 998.6 X 1085.8
917.6 X 998.6 X 827.1
822.3 X 901.7 X 912.8
822.3 X 901.7 X 827.1
682.6 X 763.6 X 827.1
.
AIR IN
AIR IN
AIR
DISCHARGE
E
5. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED.
4. CENTER OF GRAVITY
N
F
2. MINIMUM OUTDOOR
AMBIENT IN COOLING
C, MAX.OPERATING
52
MODE IS 13
3. SERIES DESIGNATION IS THE 10TH POSITION OF THE
UNIT MODEL NUMBER.
AIR IN
1. ALLOW 762.0 CLEARANCE TO SERVICE SIDE OF UNIT,
1219.2 ABOVE UNIT, 152.4 ON ONE SIDE, 304.8 ON REMAINING SIDE,
AND 609.6 BETWEEN UNITS FOR PROPER AIRFLOW.
152.9
112.5
106.1
81.6
75.7
73.9
61.7
OPERATING SHIPPING
SHIPPING
WEIGHT (Kgs)
WEIGHT (Kgs)
DIMENSIONS (L x W x H)
NOTES:
514.4
355.6
444.5
355.6
374.7
355.6
323.9
P
24ACC6
11
24”
(609.6)
Service
12”
(304.8)
12”
(304.8)
24”
(609.6)
Note: Numbers in ( ) = mm
24”
(609.6)
24”
(609.6)
Service
Wall
6”
(152.4 mm)
24”
(609.6)
Service
Wall
24”
(609.6)
12”
(304.8)
Clearances (various examples)
24”
(609.6)
Service
12”
(304.8)
24”
Service
Wall
6”
(152.4)
24ACC6
IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air.
CLEARANCES
Wall
TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Carrier database at:
http://cactaxcredits.info/carrier-ratings/ac_ratings_srch.php
Equipment performance calculator can be accessed at: http://rpmob.wrightsoft.com/
24ACC6
Model Number
24ACC618A**30
24ACC624A**30
24ACC630A**30
24ACC636A**30
24ACC642A**30
24ACC648A**30
24ACC660A**30
Indoor Model
CNPV*1917A**+TDR
CNPV*3117A**+TDR
CNPV*3117A**+TDR
CNPV*3717A**+TDR
CNPV*4324A**+TDR
CNPV*6124A**+TDR
CNPV*6124A**+TDR
Furnace Model
Capacity
18,000
23,600
28,600
34,400
41,500
46,500
55,000
EER
12.0
12.0
12.0
12.0
12.0
12.5
12.5
* AHRI = Air Conditioning, Heating & Refrigeration Institute
EER — Energy Efficiency Ratio --- ’A’ conditions --- 80_F (26.6_C) indoor db/67_F (19.4_C) indoor wb & 95_F (35_C) outdoor wb.
SEER — Seasonal Energy Efficiency Ratio
TDR — Time---Delay Relay. In most cases, only one method should be used to achieve TDR function. Using more than one method in a system may cause degradation in
performance. Use either the accessory Time---Delay Relay, KAATD0101TDR, or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
12
SEER
14.5
14.5
14.5
14.5
14.5
14.5
14.5
13
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
See notes on pg. 16
900
800
700
CFM
EWB
° F (° C)
EVAPORATOR AIR
675
600
525
CFM
EWB
° F (° C)
EVAPORATOR AIR
75 (23.9)
10.39
12.69
12.20
14.92
17.19
10.93
13.55
13.02
16.11
17.99
11.45
14.38
13.79
18.68
18.66
Sens‡
28.21
25.63
23.72
23.32
22.68
28.72
26.16
24.23
23.91
23.70
29.09
26.54
24.61
24.60
24.56
Total
13.70
16.78
16.13
19.80
22.68
14.43
17.95
17.22
21.38
23.70
15.12
19.08
18.27
24.60
24.56
Sens‡
Capacity MBtuh
21.52
19.59
18.14
17.80
17.19
21.94
19.99
18.55
18.25
17.99
22.24
20.29
18.85
18.68
18.66
Total
Capacity MBtuh
75 (23.9)
1.55
1.55
1.55
1.55
1.55
1.58
1.58
1.58
1.58
1.58
1.62
1.62
1.62
1.62
1.62
Total
System
KW**
1.18
1.18
1.18
1.18
1.18
1.21
1.20
1.20
1.20
1.20
1.23
1.23
1.23
1.23
1.23
Total
System
KW**
85 (29.4)
85 (29.4)
10.05
12.32
11.84
14.56
16.54
10.58
13.19
12.65
15.72
17.28
11.09
14.01
13.42
17.93
17.90
Sens‡
26.92
24.44
22.62
22.25
21.84
27.38
24.91
23.08
22.85
22.79
27.72
25.25
23.42
23.62
23.59
Total
13.25
16.32
15.67
19.34
21.84
13.97
17.49
16.75
22.74
22.79
14.67
18.60
17.79
23.62
23.59
Sens‡
Capacity MBtuh
20.55
18.66
17.28
16.97
16.54
20.92
19.03
17.64
17.39
17.28
21.19
19.30
17.91
17.93
17.90
Total
Capacity MBtuh
DETAILED COOLING CAPACITIES#
24ACC624A**30 Outdoor Section With CNPV*3117A** Indoor Section
1.74
25.54
12.78
1.94
24.09
12.29
1.73
23.19
15.85
1.93
21.87
15.36
1.73
21.46
15.20
1.92
20.22
14.70
1.73
21.14
18.86
1.92
20.00
19.96
1.73
20.93
20.93
1.92
19.96
19.96
1.77
25.95
13.49
1.98
24.44
12.99
1.77
23.60
17.00
1.97
22.22
16.49
1.77
21.86
16.27
1.96
20.58
15.76
1.77
21.85
21.85
1.96
20.81
20.81
1.76
21.82
21.82
1.96
20.78
20.78
1.81
26.23
14.18
2.02
24.68
13.67
1.81
23.90
18.11
2.01
22.48
17.59
1.80
22.16
17.30
2.00
20.84
16.78
1.80
22.58
22.58
2.00
21.48
21.48
1.80
22.55
22.55
2.00
21.45
21.45
Total
System
KW**
1.65
1.64
1.63
1.63
1.63
1.68
1.67
1.66
1.66
1.66
1.71
1.70
1.69
1.69
1.69
115 (46.1)
115 (46.1)
8.88
11.14
10.66
14.30
14.27
9.40
11.98
11.44
14.87
14.85
9.90
12.79
12.18
15.33
15.31
Sens‡
22.56
20.47
18.91
18.95
18.92
22.85
20.76
19.21
19.69
19.66
23.05
20.98
19.45
20.29
20.27
Total
11.77
14.84
14.18
18.95
18.92
12.47
15.96
15.22
19.69
19.66
13.15
17.05
16.23
20.29
20.27
Sens‡
Capacity MBtuh
17.15
15.54
14.37
14.30
14.27
17.39
15.78
14.60
14.87
14.85
17.55
15.95
14.78
15.33
15.31
Total
Capacity MBtuh
24ACC6
2.16
2.15
2.14
2.14
2.14
2.20
2.19
2.18
2.18
2.18
2.24
2.22
2.22
2.22
2.22
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
24ACC618A**30 Outdoor Section With CNPV*1917A** Indoor Section
1.32
19.48
9.68
1.48
18.35
9.29
1.32
17.68
11.95
1.47
16.64
11.56
1.32
16.37
11.47
1.47
15.40
11.07
1.31
16.08
14.18
1.47
15.17
13.78
1.31
15.84
15.84
1.46
15.09
15.09
1.35
19.82
10.21
1.51
18.63
9.81
1.35
18.00
12.80
1.50
16.92
12.40
1.34
16.68
12.26
1.49
15.68
11.86
1.34
16.55
16.55
1.49
15.74
15.74
1.34
16.53
16.53
1.49
15.72
15.72
1.38
20.06
10.72
1.54
18.83
10.32
1.37
18.24
13.62
1.53
17.13
13.22
1.37
16.92
13.03
1.52
15.88
12.61
1.37
17.12
17.12
1.52
16.26
16.26
1.37
17.09
17.09
1.52
16.24
16.24
Total
System
KW**
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
2.41
2.39
2.38
2.38
2.38
2.44
2.43
2.42
2.42
2.43
2.48
2.47
2.46
2.47
2.47
Total
System
KW**
1.84
1.83
1.82
1.82
1.82
1.87
1.86
1.85
1.85
1.85
1.90
1.89
1.88
1.88
1.88
Total
System
KW**
125 (51.7)
125 (51.7)
8.46
10.72
10.22
13.42
13.40
8.97
11.54
10.99
13.93
13.91
9.47
12.34
11.73
14.35
14.33
Sens‡
20.94
18.98
17.52
17.82
17.79
21.17
19.23
17.78
18.49
18.46
21.32
19.42
17.98
19.02
18.99
Total
11.24
14.29
13.62
17.82
17.79
11.93
15.41
14.66
18.49
18.46
12.60
16.48
15.65
19.02
18.99
Sens‡
Capacity MBtuh
15.88
14.37
13.27
13.42
13.40
16.07
14.57
13.47
13.93
13.91
16.20
14.72
13.63
14.35
14.33
Total
Capacity MBtuh
2.68
2.67
2.67
2.67
2.67
2.72
2.71
2.70
2.71
2.71
2.76
2.75
2.74
2.75
2.75
Total
System
KW**
2.06
2.05
2.04
2.04
2.04
2.09
2.08
2.07
2.07
2.07
2.12
2.10
2.10
2.10
2.10
Total
System
KW**
14
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
EWB
° F (° C)
See notes on pg. 16
1350
1200
1050
CFM
EVAPORATOR AIR
1125
1000
875
CFM
EWB
° F (° C)
EVAPORATOR AIR
75 (23.9)
17.01
20.96
20.15
24.86
27.76
17.91
22.41
21.50
28.77
28.93
18.77
23.80
22.78
29.93
29.89
Sens‡
41.06
37.33
34.65
34.09
33.38
41.77
38.02
35.31
34.94
34.80
42.28
38.51
35.80
36.01
35.96
Total
20.32
25.02
24.06
29.67
33.38
21.40
26.75
25.67
31.96
34.80
22.42
28.41
27.21
36.01
35.96
Sens‡
Capacity MBtuh
34.09
30.99
28.76
28.31
27.76
34.67
31.55
29.30
29.03
28.93
35.09
31.96
29.70
29.93
29.89
Total
Capacity MBtuh
75 (23.9)
2.39
2.37
2.36
2.36
2.35
2.45
2.43
2.42
2.42
2.42
2.52
2.50
2.48
2.48
2.48
Total
System
KW**
1.91
1.92
1.93
1.93
1.93
1.96
1.97
1.97
1.97
1.97
2.00
2.01
2.02
2.02
2.02
Total
System
KW**
85 (29.4)
16.48
20.43
19.62
24.31
26.76
17.37
21.86
20.95
27.89
27.84
18.22
23.24
22.23
28.78
28.74
Sens‡
39.22
35.65
33.08
32.58
32.16
39.84
36.25
33.66
33.53
33.47
40.29
36.70
34.11
34.61
34.56
Total
19.68
24.38
23.41
29.00
32.16
20.74
26.09
25.01
33.53
33.47
21.76
27.73
26.53
34.61
34.56
Sens‡
Capacity MBtuh
32.58
29.61
27.47
27.08
26.76
33.09
30.10
27.95
27.89
27.84
33.45
30.47
28.32
28.78
28.74
Total
Capacity MBtuh
85 (29.4)
24ACC636A**30 Outdoor Section With CNPV*3717A** Indoor Section
2.65
37.27
19.01
2.95
35.20
18.31
2.63
33.87
23.70
2.93
31.96
22.99
2.62
31.40
22.73
2.92
29.62
22.01
2.62
31.00
28.29
2.91
29.47
29.47
2.62
30.85
30.85
2.91
29.43
29.43
2.72
37.82
20.07
3.01
35.67
19.35
2.70
34.40
25.40
2.99
32.44
24.67
2.69
31.93
24.31
2.98
30.09
23.58
2.69
32.12
32.12
2.98
30.60
30.60
2.68
32.07
32.07
2.98
30.55
30.55
2.78
38.19
21.07
3.08
35.98
20.35
2.76
34.80
27.03
3.05
32.78
26.29
2.75
32.32
25.82
3.04
30.43
25.07
2.75
33.12
33.12
3.05
31.51
31.51
2.75
33.08
33.08
3.04
31.47
31.47
Total
System
KW**
3.28
3.26
3.25
3.25
3.25
3.35
3.32
3.31
3.32
3.32
3.41
3.39
3.38
3.38
3.38
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
2.59
2.59
2.59
2.59
2.59
2.63
2.64
2.64
2.64
2.64
2.68
2.68
2.69
2.68
2.68
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
24ACC630A**30 Outdoor Section With CNPV*3117A** Indoor Section
2.11
31.00
15.93
2.33
29.32
15.36
2.12
28.16
19.88
2.34
26.61
19.29
2.12
26.11
19.06
2.34
24.65
18.46
2.12
25.80
23.72
2.34
24.56
24.56
2.12
25.69
25.69
2.34
24.52
24.52
2.15
31.45
16.82
2.38
29.71
16.24
2.16
28.60
21.30
2.38
27.00
20.71
2.17
26.55
20.38
2.39
25.04
19.78
2.16
26.74
26.74
2.39
25.50
25.50
2.16
26.70
26.70
2.39
25.46
25.46
2.20
31.76
17.66
2.42
29.97
17.07
2.21
28.93
22.67
2.43
27.29
22.06
2.21
26.87
21.65
2.43
25.32
21.03
2.21
27.57
27.57
2.43
26.26
26.26
2.21
27.53
27.53
2.43
26.22
26.22
Total
System
KW**
DETAILED COOLING CAPACITIES# (CONT.)
115 (46.1)
115 (46.1)
14.75
18.66
17.83
23.28
23.25
15.62
20.07
19.12
24.14
24.11
16.45
21.41
20.36
24.83
24.80
Sens‡
33.01
29.95
27.73
27.95
27.91
33.39
30.35
28.13
28.97
28.93
33.65
30.65
28.44
29.80
29.76
Total
17.57
22.24
21.26
27.95
27.91
18.60
23.91
22.80
28.97
28.93
19.59
25.51
24.28
29.80
29.76
Sens‡
Capacity MBtuh
27.51
24.93
23.07
23.28
23.25
27.83
25.27
23.40
24.14
24.11
28.04
25.52
23.66
24.83
24.80
Total
Capacity MBtuh
24ACC6
3.66
3.65
3.64
3.64
3.64
3.73
3.71
3.70
3.70
3.70
3.79
3.77
3.76
3.77
3.77
Total
System
KW**
2.88
2.88
2.88
2.88
2.88
2.93
2.93
2.93
2.93
2.93
2.97
2.97
2.98
2.97
2.97
Total
System
KW**
125 (51.7)
125 (51.7)
14.09
17.99
17.13
21.87
21.83
14.95
19.37
18.42
22.64
22.61
15.78
20.69
19.61
23.26
23.23
Sens‡
30.65
27.79
25.71
26.29
26.25
30.96
28.13
26.05
27.21
27.17
31.16
28.39
26.32
27.94
27.91
Total
16.79
21.45
20.45
26.29
26.25
17.82
23.10
21.98
27.21
27.17
18.80
24.66
23.41
27.94
27.91
Sens‡
Capacity MBtuh
25.53
23.10
21.33
21.87
21.83
25.79
23.39
21.63
22.64
22.61
25.96
23.62
21.87
23.26
23.23
Total
Capacity MBtuh
4.11
4.09
4.09
4.09
4.09
4.17
4.15
4.15
4.15
4.15
4.23
4.22
4.21
4.21
4.21
Total
System
KW**
3.22
3.22
3.22
3.21
3.21
3.26
3.26
3.26
3.26
3.26
3.31
3.31
3.31
3.31
3.31
Total
System
KW**
15
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
EWB
° F (° C)
See notes on pg. 16
1800
1600
1400
CFM
EVAPORATOR AIR
1575
1400
1225
CFM
EWB
° F (° C)
EVAPORATOR AIR
75 (23.9)
24.85
30.63
29.47
36.33
40.45
26.14
32.69
31.39
39.06
42.10
27.35
34.66
33.22
43.52
43.46
Sens‡
56.17
50.88
47.10
46.38
45.57
57.16
51.83
48.01
47.62
47.51
57.88
52.53
48.69
49.20
49.13
Total
28.26
34.78
33.38
41.24
45.57
29.78
37.21
35.64
47.39
47.51
31.22
39.54
37.80
49.20
49.13
Sens‡
Capacity MBtuh
49.58
45.17
41.97
41.32
40.45
50.40
45.95
42.74
42.31
42.10
50.98
46.53
43.31
43.52
43.46
Total
Capacity MBtuh
75 (23.9)
2.67
2.84
2.95
2.96
2.98
2.70
2.88
2.99
3.00
3.00
2.74
2.92
3.04
3.02
3.03
Total
System
KW**
2.77
2.75
2.74
2.74
2.73
2.85
2.82
2.81
2.81
2.81
2.92
2.90
2.88
2.88
2.88
Total
System
KW**
85 (29.4)
24.05
29.82
28.67
35.51
38.96
25.31
31.87
30.58
40.55
40.50
26.51
33.82
32.39
41.82
41.76
Sens‡
53.35
48.38
44.81
44.21
43.79
54.20
49.20
45.60
45.65
45.58
54.82
49.82
46.20
47.12
47.06
Total
27.27
33.81
32.43
40.25
43.79
28.77
36.22
34.66
45.65
45.58
30.20
38.53
36.80
47.12
47.06
Sens‡
Capacity MBtuh
47.31
43.10
40.06
39.49
38.96
48.02
43.80
40.75
40.55
40.50
48.52
44.31
41.25
41.82
41.76
Total
Capacity MBtuh
85 (29.4)
24ACC648A**30 Outdoor Section With CNPV*6124A** Indoor Section
3.12
50.45
26.26
3.57
47.46
25.24
3.25
45.79
32.82
3.66
43.11
31.80
3.33
42.44
31.45
3.72
39.99
30.45
3.34
42.02
41.83
3.72
40.01
40.01
3.35
41.92
41.92
3.72
39.95
39.95
3.16
51.18
27.74
3.62
48.04
26.69
3.30
46.50
35.20
3.72
43.71
34.16
3.39
43.14
33.66
3.78
40.57
32.63
3.38
43.62
43.62
3.77
41.49
41.49
3.38
43.56
43.56
3.77
41.43
41.43
3.21
51.68
29.15
3.68
48.44
28.08
3.35
47.03
37.48
3.78
44.15
36.41
3.44
43.65
35.77
3.85
41.02
34.70
3.42
44.96
44.96
3.82
42.68
42.68
3.42
44.90
44.90
3.82
42.63
42.63
Total
System
KW**
115 (46.1)
115 (46.1)
21.39
27.15
26.00
33.78
33.73
22.61
29.14
27.84
34.93
34.89
23.78
31.03
29.58
35.86
35.81
Sens‡
44.32
40.30
37.39
37.89
37.83
44.79
40.79
37.89
39.20
39.15
45.10
41.17
38.28
40.26
40.21
Total
24.18
30.75
29.40
37.89
37.83
25.61
33.07
31.55
39.20
39.15
26.99
35.29
33.58
40.26
40.21
Sens‡
Capacity MBtuh
39.58
36.07
33.53
33.78
33.73
39.99
36.51
33.97
34.93
34.89
40.25
36.83
34.30
35.86
35.81
Total
Capacity MBtuh
24ACC6
4.03
4.09
4.13
4.12
4.13
4.09
4.16
4.20
4.18
4.18
4.15
4.22
4.27
4.24
4.24
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
3.80
3.76
3.74
3.74
3.74
3.87
3.84
3.82
3.82
3.82
3.95
3.91
3.89
3.90
3.90
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
24ACC642A**30 Outdoor Section With CNPV*4324A** Indoor Section
3.07
44.88
23.20
3.42
42.30
22.31
3.05
40.90
28.98
3.38
38.55
28.08
3.03
38.02
27.83
3.36
35.83
26.93
3.03
37.56
34.61
3.36
35.65
35.65
3.03
37.34
37.34
3.36
35.60
35.60
3.15
45.48
24.45
3.49
42.82
23.55
3.12
41.50
31.00
3.46
39.07
30.09
3.10
38.61
29.71
3.44
36.36
28.80
3.10
38.82
38.82
3.44
36.94
36.94
3.10
38.76
38.76
3.44
36.89
36.89
3.22
45.91
25.64
3.56
43.16
24.73
3.19
41.95
32.94
3.53
39.45
32.01
3.17
39.06
31.51
3.51
36.74
30.57
3.18
39.96
39.96
3.52
37.98
37.98
3.18
39.91
39.91
3.52
37.93
37.93
Total
System
KW**
DETAILED COOLING CAPACITIES# (CONT.)
4.51
4.55
4.57
4.56
4.56
4.58
4.62
4.64
4.63
4.63
4.64
4.69
4.71
4.70
4.70
Total
System
KW**
4.23
4.19
4.17
4.17
4.17
4.30
4.26
4.24
4.25
4.25
4.37
4.34
4.31
4.33
4.33
Total
System
KW**
125 (51.7)
125 (51.7)
20.43
26.18
25.02
31.76
31.72
21.63
28.13
26.83
32.78
32.74
22.79
29.99
28.52
33.58
33.55
Sens‡
41.00
37.32
34.65
35.59
35.54
41.35
37.73
35.07
36.74
36.69
41.56
38.05
35.42
37.65
37.61
Total
23.07
29.64
28.30
35.59
35.54
24.49
31.93
30.41
36.74
36.69
25.85
34.08
32.36
37.65
37.61
Sens‡
Capacity MBtuh
36.71
33.47
31.10
31.76
31.72
37.02
33.83
31.47
32.78
32.74
37.22
34.11
31.77
33.58
33.55
Total
Capacity MBtuh
5.02
5.04
5.05
5.05
5.05
5.10
5.12
5.13
5.12
5.12
5.17
5.19
5.20
5.19
5.19
Total
System
KW**
4.70
4.66
4.64
4.64
4.64
4.77
4.74
4.71
4.72
4.72
4.85
4.81
4.78
4.80
4.80
Total
System
KW**
16
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
66.03
60.16
55.92
55.30
54.87
66.94
61.07
56.81
57.02
56.95
67.58
61.73
57.47
58.71
58.64
Total
33.71
42.01
40.36
50.14
54.87
35.49
44.91
43.05
57.02
56.95
37.19
47.68
45.62
58.71
58.64
Sens‡
Capacity MBtuh
75 (23.9)
3.54
3.52
3.52
3.52
3.51
3.63
3.62
3.61
3.61
3.61
3.73
3.71
3.71
3.71
3.71
Total
System
KW**
62.86
57.34
53.34
52.96
52.85
63.63
58.11
54.12
54.82
54.75
64.15
58.69
54.69
56.35
56.29
Total
32.49
40.81
39.17
52.74
52.85
34.26
43.67
41.83
54.82
54.75
35.93
46.41
44.36
56.35
56.29
Sens‡
Capacity MBtuh
85 (29.4)
24ACC660A**30 Outdoor Section With CNPV*6124A**+TDR Indoor Section
3.92
59.49
31.24
4.33
55.92
29.95
3.90
54.33
39.55
4.30
51.12
38.25
3.88
50.59
37.93
4.28
47.64
36.64
3.88
50.72
50.72
4.28
48.29
48.29
3.88
50.64
50.64
4.28
48.23
48.23
4.01
60.13
32.98
4.43
56.41
31.66
3.99
55.00
42.39
4.40
51.67
41.04
3.98
51.26
40.56
4.38
48.20
39.22
3.98
52.43
52.43
4.39
49.82
49.82
3.98
52.36
52.36
4.39
49.76
49.76
4.11
60.53
34.64
4.53
56.72
33.31
4.09
55.48
45.08
4.50
52.08
43.68
4.08
51.76
43.04
4.48
48.64
41.65
4.08
53.80
53.80
4.49
51.03
51.03
4.08
53.74
53.74
4.49
50.98
50.98
Total
System
KW**
4.78
4.75
4.73
4.73
4.73
4.88
4.85
4.83
4.84
4.84
4.98
4.95
4.93
4.94
4.94
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
115 (46.1)
52.09
47.67
44.45
45.62
45.56
52.46
48.13
44.93
46.96
46.90
52.67
48.49
45.33
48.01
47.96
Total
28.60
36.88
35.28
45.62
45.56
30.30
39.62
37.80
46.96
46.90
31.92
42.18
40.11
48.01
47.96
Sens‡
Capacity MBtuh
5.29
5.26
5.23
5.24
5.24
5.39
5.36
5.34
5.35
5.35
5.49
5.46
5.43
5.45
5.45
Total
System
KW**
125 (51.7)
47.94
43.93
41.00
42.65
42.60
48.19
44.32
41.42
43.79
43.74
48.30
44.72
41.94
44.66
44.62
Total
27.18
35.42
33.82
42.65
42.60
28.86
38.08
36.25
43.79
43.74
30.47
44.52
41.94
44.66
44.62
Sens‡
Capacity MBtuh
5.86
5.83
5.81
5.83
5.83
5.96
5.93
5.91
5.93
5.93
6.06
6.03
6.01
6.03
6.03
Total
System
KW**
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F
(27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may
occur.
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
EWB — Entering Wet Bulb
2250
2000
1750
CFM
EWB
° F (° C)
EVAPORATOR AIR
DETAILED COOLING CAPACITIES# (CONT.)
24ACC6
SST
° F (° C)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)
55 (12.78)
65 (18.33)
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
15.70
66.60
0.75
17.50
67.80
0.75
19.40
69.00
0.74
21.50
70.40
0.74
23.60
71.60
0.73
25.90
73.00
0.73
14.90
76.20
0.87
16.60
77.30
0.87
18.40
78.50
0.87
20.30
79.70
0.86
22.40
80.90
0.86
24.50
82.10
0.86
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
21.10
66.10
1.00
23.40
67.20
0.99
25.80
68.40
0.98
28.50
69.60
0.97
31.20
70.80
0.96
34.20
72.10
0.95
20.10
75.80
1.15
22.20
76.80
1.15
24.60
77.90
1.14
27.00
79.00
1.14
29.60
80.10
1.14
32.40
81.30
1.13
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
24.90
68.10
1.27
27.50
69.40
1.28
30.30
70.70
1.29
33.30
72.00
1.29
36.50
73.50
1.29
39.90
75.00
1.29
23.50
77.50
1.43
26.00
78.70
1.44
28.60
79.90
1.44
31.50
81.20
1.44
34.50
82.50
1.44
37.80
84.00
1.44
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
30.40
68.90
1.49
33.50
70.10
1.49
37.00
71.40
1.50
40.60
72.80
1.51
44.50
74.40
1.53
48.70
76.00
1.55
28.80
78.20
1.72
31.80
79.30
1.73
35.10
80.60
1.73
38.60
81.90
1.75
42.30
83.30
1.76
46.20
84.90
1.79
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
24ACC618A**30
14.10
13.20
12.30
11.30
85.80
95.30
104.80
114.30
0.99
1.12
1.26
1.41
15.70
14.70
13.70
12.60
86.80
96.30
105.70
115.10
0.99
1.12
1.26
1.42
17.40
16.30
15.20
14.00
87.90
97.30
106.60
115.90
0.99
1.12
1.26
1.42
19.20
18.00
16.70
15.50
89.00
98.30
107.60
116.90
0.99
1.13
1.27
1.43
21.10
19.70
18.40
17.00
90.10
99.40
108.60
117.80
1.00
1.13
1.28
1.44
23.10
21.60
20.10
18.60
91.30
100.50
109.70
118.80
1.00
1.14
1.29
1.45
24ACC624A**30
19.00
17.90
16.70
15.40
85.30
94.90
104.40
114.00
1.31
1.47
1.65
1.86
21.00
19.80
18.50
17.10
86.30
95.80
105.30
114.70
1.31
1.47
1.66
1.86
23.20
21.80
20.40
18.90
87.30
96.70
106.10
115.50
1.31
1.48
1.66
1.87
25.50
24.00
22.40
20.80
88.30
97.70
107.00
116.30
1.31
1.48
1.67
1.87
28.00
26.30
24.60
22.80
89.40
98.70
107.90
117.20
1.31
1.49
1.67
1.88
30.60
28.80
26.90
25.00
90.50
99.70
108.90
118.10
1.31
1.49
1.69
1.90
24ACC630A**30
22.20
20.80
19.40
17.90
87.00
96.40
105.80
115.10
1.60
1.78
1.99
2.23
24.50
23.10
21.50
19.90
88.10
97.40
106.70
116.00
1.61
1.79
2.00
2.24
27.10
25.50
23.80
22.00
89.20
98.50
107.70
117.00
1.61
1.80
2.01
2.25
29.80
28.00
26.20
24.30
90.40
99.60
108.80
118.00
1.61
1.80
2.01
2.26
32.60
30.70
28.80
26.70
91.70
100.80
110.00
119.20
1.61
1.80
2.02
2.26
35.70
33.60
31.50
29.30
93.00
102.10
111.20
120.30
1.61
1.80
2.02
2.27
24ACC636A**30
27.20
25.60
23.90
22.10
87.50
96.80
106.20
115.50
1.95
2.21
2.49
2.81
30.10
28.30
26.50
24.50
88.60
97.90
107.20
116.50
1.96
2.22
2.50
2.82
33.20
31.20
29.20
27.10
89.80
99.00
108.20
117.40
1.97
2.23
2.51
2.84
36.50
34.30
32.10
29.80
91.00
100.20
109.40
118.50
1.99
2.24
2.53
2.85
40.00
37.70
35.20
32.70
92.40
101.50
110.50
119.60
2.01
2.26
2.55
2.87
43.70
41.20
38.50
35.80
93.80
102.80
111.80
120.80
2.03
2.29
2.57
2.90
See notes on page 18
17
115 (46.11)
125 (51.67)
10.20
123.70
1.60
11.50
124.40
1.60
12.80
125.20
1.60
14.10
126.10
1.61
15.60
127.00
1.62
17.10
128.00
1.63
9.20
133.10
1.81
10.30
133.80
1.81
11.50
134.50
1.81
12.80
135.30
1.82
14.10
136.20
1.82
15.50
137.10
1.84
14.10
123.40
2.09
15.60
124.10
2.10
17.30
124.80
2.10
19.10
125.60
2.11
21.00
126.40
2.12
23.00
127.30
2.13
12.70
132.80
2.37
14.10
133.50
2.37
15.70
134.10
2.37
17.40
134.90
2.37
19.10
135.60
2.38
20.90
136.40
2.39
16.20
124.40
2.50
18.10
125.30
2.51
20.10
126.20
2.52
22.30
127.20
2.53
24.50
128.20
2.54
26.90
129.30
2.54
14.40
133.60
2.81
16.20
134.40
2.82
18.10
135.30
2.83
20.10
136.30
2.85
22.20
137.20
2.86
24.40
138.20
2.86
20.20
124.90
3.20
22.50
125.80
3.20
24.90
126.70
3.21
27.40
127.70
3.23
30.10
128.70
3.24
33.00
129.80
3.26
18.20
134.20
3.64
20.30
135.00
3.65
22.60
135.90
3.65
24.90
136.80
3.66
27.40
137.70
3.67
30.00
138.70
3.69
24ACC6
CONDENSER ONLY RATINGS
CONDENSER ONLY RATINGS CONTINUED
SST
° F (° C)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
24ACC6
55
(12.78)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)
55 (12.78)
65 (18.33)
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
37.90
69.80
1.83
41.90
71.20
1.84
46.10
72.70
1.85
50.70
74.20
1.86
55.50
75.80
1.87
60.70
77.40
1.89
36.20
79.20
2.03
40.00
80.60
2.04
44.00
81.90
2.05
48.30
83.30
2.07
52.90
84.80
2.09
57.70
86.40
2.11
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
41.30
67.80
2.01
45.60
69.00
1.94
50.50
70.40
1.84
55.70
71.80
1.69
61.40
73.20
1.50
67.60
74.70
1.26
39.10
77.20
2.31
43.20
78.30
2.27
47.70
79.60
2.20
52.60
80.80
2.09
57.90
82.20
1.94
63.60
83.70
1.75
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
45.10
69.00
2.22
50.00
70.40
2.21
55.10
71.90
2.21
60.70
73.50
2.20
66.50
75.10
2.19
72.80
76.80
2.18
43.80
78.40
2.52
48.40
79.70
2.52
53.40
81.10
2.53
58.60
82.50
2.53
64.20
84.00
2.53
70.10
85.70
2.54
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
24ACC642A**30
34.30
32.30
30.10
27.90
88.70
98.10
107.40
116.70
2.26
2.54
2.86
3.22
37.90
35.70
33.30
30.80
89.90
99.20
108.40
117.70
2.28
2.56
2.88
3.24
41.70
39.20
36.70
34.00
91.20
100.40
109.60
118.70
2.30
2.58
2.90
3.26
45.80
43.10
40.20
37.30
92.50
101.60
110.80
119.80
2.32
2.60
2.92
3.29
50.10
47.10
44.00
40.80
93.90
103.00
112.00
121.00
2.34
2.63
2.95
3.32
54.60
51.30
47.90
44.40
95.40
104.40
113.40
122.30
2.36
2.66
2.99
3.36
24ACC648A**30
36.90
34.70
32.40
30.00
86.60
96.00
105.40
114.70
2.59
2.89
3.19
3.54
40.80
38.30
35.80
33.20
87.70
97.00
106.30
115.60
2.58
2.89
3.21
3.56
45.00
42.20
39.40
36.60
88.80
98.00
107.20
116.50
2.54
2.87
3.21
3.57
49.50
46.50
43.40
40.20
90.00
99.10
108.30
117.40
2.46
2.83
3.19
3.57
54.50
51.00
47.60
44.10
91.30
100.30
109.40
118.50
2.36
2.76
3.15
3.55
59.80
55.90
52.10
48.20
92.60
101.60
110.60
119.60
2.21
2.65
3.08
3.51
24ACC660A**30
42.30
40.50
38.50
36.20
87.70
97.10
106.40
115.60
2.83
3.17
3.56
4.00
46.70
44.70
42.50
40.00
89.00
98.20
107.40
116.60
2.85
3.19
3.58
4.03
51.40
49.20
46.70
44.00
90.20
99.40
108.50
117.60
2.86
3.21
3.61
4.05
56.40
54.00
51.20
48.20
91.60
100.70
109.70
118.70
2.87
3.23
3.63
4.08
61.70
59.00
56.00
52.60
93.00
102.00
111.00
119.90
2.89
3.26
3.66
4.11
67.30
64.20
60.90
57.20
94.50
103.40
112.30
121.10
2.90
3.28
3.69
4.15
* AHRI listing applies only to systems shown in Combination Ratings table.
KW --- Outdoor Unit Kilowatts Only.
SDT --- Saturated Temperature Leaving Compressor (° F)
SST --- Saturated Temperature Entering Compressor (° F/° C)
TCG --- Gross Cooling Capacity (1000 Btuh)
18
115 (46.11)
125 (51.67)
25.50
125.90
3.63
28.30
126.80
3.65
31.20
127.80
3.67
34.30
128.90
3.70
37.50
130.00
3.73
40.80
131.20
3.77
23.00
135.10
4.09
25.60
136.00
4.10
28.30
136.90
4.13
31.10
137.90
4.15
34.10
138.90
4.19
37.10
140.00
4.22
27.50
124.00
3.93
30.40
124.80
3.95
33.60
125.70
3.97
36.90
126.60
3.98
40.50
127.50
3.98
44.20
128.50
3.97
24.80
133.30
4.38
27.60
134.10
4.39
30.50
134.80
4.41
33.50
135.70
4.43
36.70
136.50
4.44
40.10
137.40
4.44
33.50
124.80
4.53
37.10
125.80
4.55
40.80
126.70
4.57
44.80
127.70
4.60
48.90
128.80
4.63
53.10
129.90
4.66
30.50
134.00
5.15
33.80
134.90
5.16
37.30
135.70
5.18
41.00
136.70
5.20
44.70
137.60
5.22
48.60
138.60
5.25
System Description
Outdoor--mounted, air--cooled, split--system air conditioner unit
suitable for ground or rooftop installation. Unit consists of a
hermetic compressor, an air--cooled coil, propeller--type
condenser fan, and a control box. Unit will discharge supply air
upward as shown on contract drawings. Unit will be used in a
refrigeration circuit to match up to a packaged fan coil or coil
unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition
of AHRI Standard 210.
— Unit will be certified for capacity and efficiency, and
listed in the latest AHRI directory.
— Unit construction will comply with latest edition of
ANSI/ ASHRAE and with NEC.
— Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit
will have c--UL--us approval.
— Unit cabinet will be capable of withstanding Federal
Test Method Standard No. 141 (Method 6061) 500--hr
salt spray test.
— Air--cooled condenser coils will be leak tested at 150
psig and pressure tested at 450 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is
stored and handled per unit manufacturer’s
recommendations.
Warranty (for inclusion by specifying engineer)
— U.S. and Canada only.
PRODUCTS
Equipment
Factory assembled, single piece, air--cooled air conditioner unit.
Contained within the unit enclosure is all factory wiring, piping,
controls, compressor, refrigerant charge Puronr (R--410A), and
special features required prior to field start--up.
Unit Cabinet
— Unit cabinet will be constructed of galvanized steel,
bonderized, and coated with a powder coat paint.
AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER
24ACC6
1--1/2 TO 5 NOMINAL TONS
Fans
— Condenser fan will be direct--drive propeller type,
discharging air upward.
— Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated
steel wire safety guards.
Compressor
— Compressor will be hermetically sealed.
— Compressor will be mounted on rubber vibration
isolators.
Condenser Coil
— Condenser coil will be air cooled.
— Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned,
dehydrated, and sealed.
Refrigeration Components
— Refrigeration circuit components will include
liquid--line shutoff valve with sweat connections,
vapor--line shutoff valve with sweat connections,
system charge of Puronr (R--410A) refrigerant, and
compressor oil.
— Unit will be equipped with high--pressure switch, low
pressure switch and filter drier for Puron refrigerant.
Operating Characteristics
— The capacity of the unit will meet or exceed _____
Btuh at a suction temperature of _____ _F/_C. The
power consumption at full load will not exceed _____
kW.
— Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____
Btuh or greater at conditions of _____ CFM entering
air temperature at the evaporator at _____ _F/_C wet
bulb and _____ _F/_C dry bulb, and air entering the
unit at _____ _F/_C.
— The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
19
24ACC6
GUIDE SPECIFICATIONS
GENERAL
SYSTEM DESIGN SUMMARY
1.
2.
3.
4.
5.
6.
7.
24ACC6
8.
9.
Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc.
Minimum outdoor operating air temperature for cooling mode without low--ambient operation accessory is 55_F (12.8_C).
Maximum outdoor operating air temperature is 125_F (51.7_C).
For reliable operation, unit should be level in all horizontal planes.
For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or 35 ft (10.7 m) vertical differential, consult Residential
Piping and Longline Guideline and Service Manual available from equipment distributor.
If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4
mm).
Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
Do not apply capillary tube indoor coils to these units.
Factory--supplied filter drier must be installed.
Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Edition Date: 09/12
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
20
Catalog No: 24ACC6---4PD
Replaces: 24ACC6--- 3PD
CNPHP, CNRHP
Evaporator Coil
N Coil --- Cased
Horizontal
Product Data
This horizontal design N--coil is an evaporator coil designed to
provide the highest standards of reliability and durability. The coils
are available for use in Puronr, the environmentally friendly
refrigerant, and R--22 systems.
Both designs have a painted case (taupe metallic) and come with
factory--installed thermostatic expansion valves (TXV). The coils
are offered in different cabinet configurations for use in multiple
installation applications. Easy maintenance is provided as the coil
slides out of the cabinet after removing the access door and service
panel. The coils are available in sizes 024 through 061 (2 to 5
tons).
Tin Plated Copper Coils – “T” models are built with special
hairpins, tin plated to resist both general pitting corrosion and
excessive indoor Formicary Corrosion. (Formicary Corrosion is an
industry phenomenon.)
Aluminum Coils – “L” models are built with aluminum hairpins,
designed to resist both general pitting corrosion and excessive
indoor-Formicary Corrosion. (Formicary Corrosion is an industry
phenomenon.)
DESIGN FEATURES
CNPHP / CNRHP
A06005
Water Management — These coil designs do an excellent job of
water management. The coils are designed to avoid water blow--off
into the ducts by directing condensate away from the fins and into
the drain pan. The coil drain pan design provides improved
condensate removal into the drain. This improves indoor air
quality.
Durable Condensate Pan — Each coil is equipped with a
corrosion--resistant condensate drain pan. The condensate drain
pan is designed with a slope to help ensure proper drainage,
improved moisture removal, and home comfort.
Compact Design — The unique design is great for all those
horizontal applications. They are designed for either
horizontal--right or horizontal--left furnace fit up. The coil is ideally
suited for either attic or crawl space installation.
Brass Inserts — Every condensate pan features two 3/4--in. female
threaded brass insert connections. The unique brass inserts provide
for a leak--free condensate line connection to prevent water
damage.
Refrigerant Connections — The coils are provided with proven
sweat connections for leak--free operation maintaining system
reliability.
Burst Pressures — These coils meet or exceed burst pressure of
2100 psi which is at least three to five times the pressure they will
see in actual application.
Thermostatic Expansion Valves (TXV) — All the Carrier coils
have refrigerant--specific factory--installed TXVs.
Teflon Ring — The ring, installed inside the liquid line connection
at the TXV is the best option for preventing refrigerant leaks and
future service calls. Teflon works with both Puronr and R--22
refrigerants.
MODEL NUMBER NOMENCLATURE
1
2
3
4
5
6
7
8
9
10
11
12
C
N
P
H
P
2
4
1
7
A
C
A
Product
C = Coil
Variations
A = Basic
CNPHP / CNRHP
Type
N = N Coil
Tubing Design
C = Copper
L = Aluminum
T = Tin--- Plated Copper
Refrigerant Type
P = Puronr Refrigerant TXV
R = R--- 22 TXV
Revision Level
A = 1st
Coil Configuration
H = Horizontal
Cabinet Width
17 = 17--- in / 432mm
21 = 21--- in / 533mm
24 = 24--- in / 610mm
Cabinet Finish
P = Painted
Unit Capacity
24 = 2 Ton
30 = 2 1/2 Ton
31 = 2 1/2 Ton
36 = 3 Ton
42 = 3 1/2 Ton
43 = 3 1/2 Ton
48 = 4 Ton
60 = 5 Ton
61 = 5 Ton
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
the environmentally sound refrigerant
2
CNPHP / CNRHP
DIMENSIONS
A05430
DIMENSIONS
CN(P,R)HP
SERIES
2417A(C,T)A
A
3017A(C,T)A
A
3617A(C,T)A
A
4221A(C,T)A
A
4821A(C,T)A
A
6024A(C,T)A
A
6124A(C,T)A
A
CNPHP
SERIES
3117A(C,T)A
B
4321A(C,T)A
B
A
in.
(mm)
B
in.
(mm)
C
in.
(mm)
D
in.
(mm)
E
in.
(mm)
F
in.
(mm)
17--- 1/2
(445)
17--- 1/2
(445)
17--- 1/2
(445)
21
(533)
21
(533)
24--- 1/2
(622)
24--- 1/2
(622)
19
(483)
22--- 1/16
(560)
22--- 1/16
(560)
22--- 1/16
(560)
28--- 1/16
(713)
29
(737)
29
(737)
10--- 3/4
(273)
10--- 5/16
(262)
10--- 5/16
(262)
10--- 5/16
(262)
13--- 3/16
(335)
14--- 1/8
(359)
14--- 1/8
(359)
9--- 5/16
(237)
8--- 7/16
(214)
8--- 7/16
(214)
8--- 7/16
(214)
8--- 7/16
(214)
9--- 5/16
(237)
9--- 5/16
(237)
16
(406)
16
(406)
16
(406)
19--- 1/2
(495)
19--- 1/2
(495)
23
(584)
23
(584)
5/8
(16)
3/4
(19)
3/4
(19)
7/8
(22)
7/8
(22)
7/8
(22)
7/8
(22)
A
in.
(mm)
B
in.
(mm)
C
in.
(mm)
D
in.
(mm)
E
in.
(mm)
F
in.
(mm)
17--- 9/16
(446)
21--- 1/16
(535)
27--- 1/2
(699)
30--- 1/8
(765)
12--- 7/16
(316)
21--- 1/16
(386)
7--- 13/16
(198)
10--- 1/2
(267)
16
(406)
19--- 1/2
(495)
3/4
(19)
7/8
(22)
3
SHIPPING WT. LBS. (KG)
Non--Tin---Coated
Coated
Hairpins
Hairpins
(T)
(C)
39.5
41.5
(18)
(19)
50.0
53.0
(23)
(24)
49.5
52.5
(22)
(24)
59.0
62.0
(27)
(28)
71.0
73.5
(32)
(33)
81.0
84.0
(37)
(38)
88
91
(194)
(201)
SHIPPING WT. LBS. (KG)
Non--Tin---Coated
Coated
Hairpins
Hairpins
(T)
(C)
44.1
50.7
(20)
(23)
59.1
61.7
(26.8)
(28)
CNPHP / CNRHP
DIMENSIONS (cont.)
A12030
4
CNPHP / CNRHP
DIMENSIONS (cont.)
A12031
5
PERFORMANCE DATA
COOLING CAPACITIES (MBH) -- PURONr REFRIGERANT
CNPH
UNIT
SIZE
CNPHP / CNRHP
2417
3017
3117
3617
4221
4321
4821
INDOOR COIL
AIR
CFM
EWB
72(22)
67(19)
600
62(17)
72(22)
67(19)
800
62(17)
72(22)
67(19)
1000
62(17)
72(22)
67(19)
750
62(17)
72(22)
67(19)
1000
62(17)
72(22)
67(19)
1250
62(17)
72(22)
67(19)
750
62(17)
72(22)
67(19)
1000
62(17)
72(22)
67(19)
1250
62(17)
72(22)
67(19)
900
62(17)
72(22)
67(19)
1200
62(17)
72(22)
67(19)
1500
62(17)
72(22)
67(19)
1050
62(17)
72(22)
67(19)
1400
62(17)
72(22)
67(19)
1750
62(17)
72(22)
67(19)
1050
62(17)
72(22)
67(19)
1400
62(17)
72(22)
67(19)
1750
62(17)
72(22)
67(19)
1200
62(17)
72(22)
67(19)
1600
62(17)
72(22)
67(19)
2000
62(17)
30 (---1)
TC
SHC
39.00 19.00
32.80 19.80
27.20 20.50
47.10 22.80
39.80 24.20
33.10 25.40
53.40 25.90
45.30 27.90
37.80 29.60
48.00 23.50
40.30 24.20
33.20 24.80
58.70 28.50
49.40 29.90
40.80 30.90
67.40 32.70
56.80 34.70
47.10 36.30
74.50 37.07
62.13 37.73
50.98 38.20
92.35 45.51
77.15 46.96
63.39 48.06
107.37 52.63
89.89 54.97
73.97 56.83
58.10 28.30
48.90 29.50
40.40 30.40
70.00 33.90
58.90 35.90
48.80 37.50
79.30 38.60
67.00 41.30
55.70 43.60
74.40 36.30
62.30 37.60
51.40 38.60
90.20 43.80
75.80 46.00
62.60 47.70
103.00 50.00
86.70 53.10
71.70 55.70
96.72 47.64
80.93 49.26
66.64 50.56
117.07 57.30
98.18 60.23
81.03 62.70
133.38 65.28
112.09 69.50
92.72 73.26
79.30 38.70
66.60 40.20
55.00 41.30
96.00 46.60
80.90 49.20
67.00 51.20
109.40 53.10
92.40 56.70
76.70 59.70
See NOTES next page.
Legend:
CFM --- Cubic Ft. per Minute
SHC --- Gross Sensible Capacity 1000 Btuh
BF
0.00
0.01
0.02
0.00
0.03
0.03
0.00
0.05
0.05
0.00
0.01
0.02
0.00
0.03
0.04
0.00
0.05
0.06
0.00
0.01
0.01
0.00
0.02
0.02
0.00
0.03
0.03
0.00
0.02
0.03
0.00
0.05
0.06
0.00
0.08
0.09
0.00
0.02
0.03
0.00
0.05
0.06
0.00
0.08
0.09
0.00
0.01
0.01
0.00
0.03
0.03
0.00
0.04
0.05
0.00
0.02
0.03
0.00
0.04
0.05
0.00
0.06
0.07
SATURATED TEMPERATURE LEAVING EVAPORATOR _F (_C)
35 (2)
40 (4)
45 (7)
TC
SHC
BF
TC
SHC
BF
TC
SHC
BF
36.00 17.50 0.00 32.70 15.90 0.00 28.80 14.10 0.00
29.80 18.20 0.01 26.30 16.40 0.01 22.40 14.60 0.02
24.00 18.70 0.02 20.50 16.90 0.02 16.60 15.00 0.02
43.60 21.10 0.00 39.60 19.30 0.00 35.00 17.30 0.02
36.10 22.30 0.03 32.00 20.30 0.03 27.30 18.10 0.03
29.30 23.40 0.03 25.10 21.20 0.03 20.50 19.00 0.04
49.50 24.20 0.00 45.10 22.10 0.02 40.00 19.90 0.03
41.20 25.90 0.05 36.60 23.70 0.05 31.30 21.30 0.05
33.60 27.40 0.05 28.80 25.10 0.05 23.80 22.70 0.06
44.00 21.40 0.00 39.70 19.20 0.00 34.80 17.00 0.00
36.20 22.00 0.02 31.80 19.70 0.02 26.80 17.40 0.02
29.10 22.50 0.02 24.60 20.20 0.02 19.90 17.90 0.02
53.90 26.10 0.00 48.50 23.60 0.00 42.50 20.90 0.02
44.40 27.30 0.03 38.90 24.60 0.04 32.90 21.70 0.04
35.80 28.20 0.04 30.30 25.40 0.04 24.60 22.60 0.05
61.90 30.10 0.00 55.70 27.30 0.02 48.80 24.20 0.04
51.20 31.80 0.06 44.90 28.70 0.06 37.80 25.50 0.06
41.30 33.20 0.06 35.00 30.10 0.06 28.60 27.00 0.07
68.51 33.85 0.00 61.86 30.50 0.00 54.41 27.00 0.00
56.03 34.37 0.01 49.24 30.87 0.01 41.66 27.24 0.01
44.75 34.72 0.01 37.95 31.17 0.01 30.17 27.36 0.01
85.01 41.76 0.00 76.78 37.78 0.00 67.46 33.54 0.01
69.62 42.94 0.02 61.18 38.71 0.02 51.69 34.27 0.02
55.66 43.85 0.02 47.21 39.53 0.02 38.21 35.15 0.02
98.97 48.52 0.00 89.37 44.04 0.01 78.59 39.23 0.02
81.19 50.47 0.03 71.37 45.67 0.03 60.28 40.57 0.03
64.99 52.05 0.03 55.22 47.14 0.03 44.93 42.16 0.04
53.40 25.90 0.00 48.00 23.30 0.00 42.10 20.60 0.01
44.00 26.90 0.03 38.50 24.20 0.03 32.50 21.30 0.03
35.40 27.70 0.03 29.90 24.90 0.03 24.20 22.10 0.04
64.30 31.20 0.00 57.80 28.30 0.02 50.70 25.10 0.04
53.10 32.90 0.05 46.50 29.70 0.05 39.30 26.40 0.06
42.80 34.30 0.06 36.30 31.00 0.06 29.60 27.80 0.06
72.90 35.60 0.02 65.70 32.30 0.05 57.50 28.80 0.06
60.40 38.00 0.08 53.00 34.40 0.08 44.70 30.70 0.08
48.80 40.00 0.09 41.60 36.50 0.09 34.20 32.90 0.10
68.10 33.10 0.00 61.20 29.70 0.00 53.50 26.20 0.01
56.00 34.20 0.03 48.90 30.60 0.03 41.20 27.00 0.03
44.90 35.00 0.03 37.90 31.40 0.03 30.60 27.80 0.04
82.60 40.10 0.00 74.10 36.20 0.01 64.70 32.00 0.04
68.00 42.00 0.05 59.40 37.70 0.06 50.00 33.40 0.06
54.70 43.50 0.06 46.20 39.20 0.06 37.50 35.00 0.07
94.30 46.00 0.00 84.60 41.50 0.05 73.90 36.80 0.06
77.80 48.60 0.08 68.00 43.90 0.08 57.10 39.00 0.08
62.70 50.90 0.09 53.10 46.20 0.09 43.40 41.50 0.10
89.31 43.85 0.00 80.91 39.78 0.00 71.39 35.44 0.00
73.30 45.20 0.01 64.67 40.88 0.01 54.97 36.34 0.01
58.77 46.28 0.01 50.10 41.84 0.01 40.70 37.29 0.02
108.20 53.03 0.00 98.03 48.31 0.01 86.74 43.33 0.02
89.03 55.55 0.03 78.69 50.55 0.03 66.93 45.19 0.03
71.60 57.72 0.03 61.25 52.56 0.03 50.15 47.21 0.03
123.30 60.58 0.02 111.98 55.48 0.03 99.21 50.01 0.04
101.79 64.41 0.05 90.14 58.95 0.05 76.76 52.99 0.05
82.16 67.85 0.05 70.58 62.18 0.05 58.38 56.24 0.06
72.90 35.40 0.00 65.70 31.90 0.00 57.70 28.20 0.00
60.00 36.60 0.02 52.70 32.90 0.02 44.60 29.10 0.02
48.30 37.60 0.03 40.90 33.80 0.03 33.10 30.00 0.03
88.30 42.90 0.00 79.60 38.90 0.00 69.90 34.50 0.03
72.90 45.00 0.04 64.10 40.70 0.05 54.20 36.10 0.05
58.80 46.80 0.05 49.90 42.30 0.05 40.70 37.90 0.05
100.70 49.10 0.00 90.90 44.60 0.03 79.90 39.80 0.05
83.40 52.20 0.07 73.30 47.40 0.07 62.00 42.20 0.07
67.50 54.90 0.08 57.40 49.90 0.08 47.20 44.90 0.08
EWB --- Entering Wet Bulb
BF --- Bypass Factor
LWB --- Leaving Wet Bulb
MBH --- 1000 Btuh
6
TC
24.60
18.10
13.10
29.90
22.00
16.70
34.10
25.20
20.00
29.40
21.40
15.60
35.80
26.20
19.90
41.10
30.10
23.70
46.04
32.96
23.70
57.03
41.04
30.59
66.39
47.77
36.94
35.50
25.90
19.40
42.70
31.20
24.40
48.50
35.50
28.80
45.00
32.80
24.40
54.40
39.60
30.70
62.00
45.20
36.30
60.74
43.99
32.63
73.81
53.54
41.46
84.49
61.46
49.33
48.80
35.70
26.30
59.10
43.30
33.30
67.50
49.50
39.50
50 (10)
SHC
12.30
12.60
13.10
15.10
15.90
16.70
17.50
18.70
20.00
14.60
15.00
15.60
18.10
18.80
19.90
21.00
22.20
23.70
23.35
23.39
23.70
29.08
29.62
30.59
34.13
35.20
36.94
17.80
18.40
19.40
21.80
22.90
24.40
25.10
26.80
28.80
22.60
23.30
24.40
27.60
28.90
30.70
32.00
33.90
36.30
30.89
31.53
32.63
37.96
39.46
41.46
44.04
46.55
49.33
24.40
25.10
26.30
30.00
31.40
33.30
34.70
36.90
39.50
TC --- Gross Cooling Capacity 1000 Btuh
BF
0.01
0.02
0.05
0.02
0.03
0.09
0.04
0.05
0.13
0.01
0.02
0.05
0.03
0.04
0.10
0.05
0.06
0.14
0.00
0.01
0.06
0.01
0.02
0.08
0.02
0.03
0.11
0.02
0.03
0.08
0.05
0.06
0.13
0.07
0.09
0.18
0.02
0.03
0.08
0.05
0.06
0.13
0.07
0.09
0.18
0.01
0.01
0.07
0.02
0.03
0.11
0.04
0.05
0.15
0.01
0.03
0.07
0.04
0.05
0.11
0.06
0.07
0.16
PERFORMANCE DATA (cont.)
INDOOR
CNPH
COIL AIR
UNIT
SIZE CFM EWB
72(22)
1600 67(19)
62(17)
72(22)
6024
2000 67(19)
62(17)
72(22)
2400 67(19)
62(17)
72(22)
1600 67(19)
62(17)
72(22)
6124
2000 67(19)
62(17)
72(22)
2400 67(19)
62(17)
30 (---1)
TC
SHC
103.20 50.40
86.40 52.10
71.20 53.30
120.70 58.70
101.20 61.30
83.40 63.20
135.60 65.80
113.90 69.30
94.10 72.10
142.31 69.71
119.05 72.45
97.96 74.63
164.20 80.16
137.68 84.38
113.54 87.89
182.47 89.12
153.40 94.82
126.74 99.73
Legend:
CFM --- Cubic Ft. per Minute
SHC --- Gross Sensible Capacity 1000 Btuh
BF
0.00
0.02
0.03
0.00
0.03
0.05
0.00
0.05
0.06
0.00
0.02
0.03
0.00
0.04
0.04
0.00
0.05
0.06
SATURATED TEMPERATURE LEAVING EVAPORATOR _F (_C)
35 (2)
40 (4)
45 (7)
TC
SHC
BF
TC
SHC
BF
TC
SHC
BF
94.40 45.90 0.00 84.80 41.10 0.00 74.10 36.30 0.00
77.50 47.20 0.02 67.80 42.30 0.02 57.10 37.20 0.03
62.20 48.30 0.03 52.40 43.30 0.03 42.30 38.30 0.03
110.40 53.60 0.00 99.00 48.20 0.00 86.40 42.50 0.02
90.70 55.70 0.04 79.20 50.00 0.04 66.60 44.10 0.04
72.80 57.40 0.05 61.40 51.60 0.05 49.70 46.00 0.05
124.10 60.30 0.00 111.20 54.40 0.01 97.00 48.00 0.04
102.10 63.20 0.06 89.10 56.90 0.06 74.80 50.30 0.06
82.10 65.70 0.06 69.30 59.30 0.06 56.40 53.00 0.07
131.14 64.12 0.00 118.67 58.20 0.00 104.55 51.83 0.01
107.63 66.45 0.02 94.79 60.09 0.02 80.30 53.36 0.02
86.21 68.29 0.02 73.29 61.74 0.02 59.53 55.08 0.03
151.58 74.13 0.00 137.25 67.52 0.02 121.04 60.38 0.03
124.66 77.75 0.04 109.89 70.63 0.04 93.13 63.00 0.04
100.05 80.79 0.04 85.34 73.48 0.04 69.79 65.96 0.05
168.62 82.68 0.02 152.91 75.56 0.04 134.97 67.83 0.04
139.05 87.71 0.05 122.70 80.00 0.05 104.07 71.67 0.06
111.87 92.08 0.06 95.76 84.19 0.06 78.98 76.01 0.07
EWB --- Entering Wet Bulb
BF --- Bypass Factor
LWB --- Leaving Wet Bulb
MBH --- 1000 Btuh
TC
62.40
45.40
33.50
72.60
52.80
40.30
81.30
59.20
46.50
88.62
63.94
48.11
102.61
74.14
57.86
114.48
82.87
66.58
50 (10)
SHC
31.20
32.10
33.50
36.70
38.10
40.30
41.50
43.60
46.50
45.08
46.26
48.11
52.74
54.89
57.86
59.50
62.74
66.58
BF
0.02
0.03
0.07
0.03
0.05
0.11
0.05
0.06
0.14
0.02
0.02
0.09
0.03
0.04
0.12
0.05
0.06
0.16
TC --- Gross Cooling Capacity 1000 Btuh
NOTES:
1. Contact manufacturer for cooling capacities at conditions other than shown in table.
2. Formulas:
Leaving db = entering db -- sensible heat cap.
1.09 x CFM
Leaving wb = wb corresponding to enthalpy of air leaving coil (hLWB)
hLWB = hEWB -- total capacity (Btuh)
4.5 x CFM
3.
4.
5.
6.
7.
8.
9.
10.
11.
Where hEWB = enthalpy of air entering coil
SHC is based on 80°F (27°C) db temperature of air entering the evaporator coil.
Below 80°F (27°C) db, subtract (Correction Factor x CFM) from SHC.
Above 80°F (27°C) db, add (Correction Factor x CFM) to SHC.
Direct interpolation is permissible. Do not extrapolate.
Fan motor heat has not been deducted.
All data points are based on 10°F (--12°C) superheat leaving coil and use of thermostatic expansion valve (TXV) device.
All units have sweat suction--tube connection and a liquid--tube connection. For 1--1/8--in. system suction tube, 3/4 x 1--1/8--in. suction
tube connection adapter is available as accessory.
The CNPHP coils can be used in any properly designed system using Puronr refrigerant.
The CNRHP coils can be used in any properly designed system using R--22 refrigerant.
Before using maximum cfm shown in table, check coil static pressure drop to ensure system blower can provide necessary static
pressure needed for coil and duct systems.
Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation.
BYPASS FACTOR
79 (26)
81 (27)
0.10
0.20
0.30
0.98
0.87
0.76
ENTERING AIR DRY BULB TEMPERATURE _F (_C)
77 (25)
76 (24)
75 (24)
Under 75 (24)
83 (28)
84 (29)
84 (29)
Above 85 (29)
Correction Factor
1.96
2.94
3.92
4.91
1.74
2.62
3.49
4.36
Use formula shown below
1.53
2.29
3.05
3.82
78 (26)
82 (28)
Interpolation is permissible.
Correction Factor = 1.09 x (1 --- BF) x (db --- 80)
7
CNPHP / CNRHP
COOLING CAPACITIES (MBH) -- PURONr REFRIGERANT
PERFORMANCE DATA (cont.)
COOLING CAPACITIES (MBH) -- R--22 REFRIGERANT
CNRH
UNIT
SIZE
CNPHP / CNRHP
2417
3017
3617
4221
4821
6024
INDOOR COIL
AIR
CFM
EWB
72(22)
67(19)
600
62(17)
72(22)
67(19)
800
62(17)
72(22)
67(19)
1000
62(17)
72(22)
67(19)
750
62(17)
72(22)
67(19)
1000
62(17)
72(22)
67(19)
1250
62(17)
72(22)
67(19)
900
62(17)
72(22)
67(19)
1200
62(17)
72(22)
67(19)
1500
62(17)
72(22)
67(19)
1050
62(17)
72(22)
67(19)
1400
62(17)
72(22)
67(19)
1750
62(17)
72(22)
67(19)
1200
62(17)
72(22)
67(19)
1600
62(17)
72(22)
67(19)
2000
62(17)
72(22)
67(19)
1600
62(17)
72(22)
67(19)
2000
62(17)
72(22)
67(19)
2400
62(17)
30 (---1)
TC
SHC
34.60 16.80
29.40 18.30
24.70 19.50
39.50 19.40
33.90 21.60
28.60 23.70
43.20 21.50
37.10 24.50
31.50 27.30
45.90 22.30
38.90 23.70
32.30 24.80
53.80 26.20
45.70 28.40
38.30 30.40
59.80 29.30
50.90 32.30
42.70 35.10
53.50 26.00
45.40 27.90
37.90 29.70
61.60 30.10
52.40 33.10
44.00 35.90
67.50 33.40
57.70 37.40
48.60 41.20
67.70 32.90
57.10 35.00
47.40 36.80
79.00 38.50
66.90 41.80
55.70 44.70
87.40 42.90
74.30 47.40
62.20 51.40
72.40 35.20
61.40 37.70
51.20 40.00
83.80 41.00
71.40 44.90
59.80 48.50
92.10 45.50
78.70 50.90
66.30 55.90
93.60 45.40
78.90 48.10
65.40 50.40
106.40 51.70
89.90 55.50
74.70 58.90
116.60 57.00
98.90 61.90
82.30 66.40
BF
0.00
0.01
0.02
0.01
0.03
0.03
0.03
0.05
0.05
0.00
0.02
0.02
0.00
0.03
0.04
0.03
0.06
0.06
0.00
0.03
0.03
0.02
0.05
0.06
0.06
0.08
0.08
0.00
0.03
0.03
0.00
0.05
0.06
0.04
0.08
0.09
0.00
0.02
0.03
0.00
0.04
0.05
0.04
0.07
0.07
0.00
0.02
0.03
0.00
0.04
0.04
0.00
0.06
0.06
SATURATED TEMPERATURE LEAVING EVAPORATOR _F (_C)
35 (2)
40 (4)
45 (7)
TC
SHC
BF
TC
SHC
BF
TC
SHC
BF
32.30 15.70 0.00 29.60 14.60 0.00 26.50 13.20 0.00
27.00 17.10 0.01 24.20 15.70 0.01 20.90 14.30 0.01
22.20 18.30 0.02 19.30 16.80 0.02 16.00 15.30 0.02
37.10 18.40 0.01 34.20 17.10 0.02 30.70 15.70 0.02
31.20 20.40 0.03 28.00 19.00 0.03 24.30 17.40 0.03
25.80 22.30 0.03 22.60 20.80 0.04 19.30 19.10 0.05
40.60 20.50 0.04 37.50 19.20 0.04 33.80 17.70 0.04
34.30 23.20 0.05 30.90 21.80 0.05 26.80 20.10 0.05
28.60 25.90 0.05 25.30 24.30 0.06 22.30 22.30 0.11
42.50 20.60 0.00 38.60 18.80 0.00 34.10 16.80 0.01
35.30 21.90 0.02 31.00 19.80 0.02 26.00 17.50 0.02
28.30 22.80 0.02 24.00 20.60 0.02 19.30 18.30 0.03
49.90 24.40 0.01 45.40 22.40 0.02 40.30 20.20 0.03
41.60 26.40 0.04 37.00 24.20 0.04 31.20 21.70 0.04
34.00 28.20 0.04 29.00 25.80 0.04 23.80 23.20 0.06
55.50 27.40 0.04 50.60 25.30 0.04 44.80 22.90 0.05
46.40 30.20 0.06 41.30 27.80 0.06 35.40 25.30 0.06
38.30 32.90 0.06 33.10 30.30 0.07 27.70 27.50 0.09
49.50 24.10 0.00 45.10 22.10 0.01 40.00 19.90 0.02
41.30 25.90 0.03 36.60 23.70 0.03 30.70 21.10 0.03
33.50 27.40 0.03 28.50 24.90 0.03 23.20 22.30 0.05
57.20 28.20 0.03 52.10 26.00 0.04 46.20 23.50 0.04
47.80 30.90 0.05 42.50 28.50 0.05 36.30 25.80 0.06
39.40 33.60 0.06 34.00 30.90 0.06 28.30 28.00 0.08
62.90 31.40 0.06 57.40 29.10 0.07 50.80 26.50 0.07
52.70 35.10 0.08 46.90 32.60 0.08 40.30 29.80 0.08
43.70 38.80 0.09 38.30 36.10 0.09 32.90 32.90 0.13
62.50 30.40 0.00 56.50 27.60 0.00 49.70 24.70 0.02
51.70 32.20 0.03 45.60 29.30 0.03 38.80 26.20 0.03
41.90 33.90 0.03 35.70 30.80 0.03 28.90 27.50 0.04
73.10 35.80 0.02 66.20 32.80 0.04 58.30 29.40 0.04
60.70 38.70 0.05 53.50 35.40 0.06 45.50 31.90 0.06
49.40 41.50 0.06 42.60 38.10 0.06 35.40 34.50 0.08
81.00 40.10 0.06 73.60 37.00 0.07 64.90 33.40 0.07
67.60 44.20 0.08 59.70 40.60 0.08 50.60 36.70 0.08
55.30 48.10 0.09 47.90 44.50 0.09 40.70 40.70 0.11
67.30 32.70 0.00 61.20 30.00 0.00 54.20 27.00 0.01
55.90 35.00 0.02 49.50 32.00 0.02 42.40 28.80 0.02
45.50 37.00 0.03 39.20 33.90 0.03 32.20 30.50 0.03
78.00 38.40 0.02 71.30 35.40 0.03 63.30 32.10 0.03
65.20 42.00 0.04 58.00 38.70 0.05 49.50 35.00 0.05
53.40 45.30 0.05 46.30 41.90 0.05 39.00 38.30 0.07
86.00 42.90 0.05 78.70 39.80 0.05 70.10 36.40 0.06
72.10 47.80 0.07 64.30 44.40 0.07 55.10 40.40 0.07
59.60 52.60 0.07 52.10 48.90 0.08 44.90 44.90 0.11
86.30 41.90 0.00 77.90 38.00 0.00 68.30 33.80 0.01
71.20 44.20 0.02 62.70 40.10 0.02 53.20 35.70 0.03
57.70 46.30 0.03 49.20 42.00 0.03 39.60 37.40 0.04
98.20 47.90 0.00 88.80 43.70 0.02 78.00 39.10 0.03
81.30 51.30 0.04 71.50 46.70 0.04 60.60 41.80 0.04
65.90 54.40 0.04 56.60 49.70 0.05 46.50 44.80 0.06
107.90 53.00 0.03 97.70 48.50 0.04 85.90 43.60 0.05
89.60 57.50 0.06 78.90 52.50 0.06 66.60 47.20 0.06
72.90 61.70 0.06 62.70 56.70 0.07 52.60 51.60 0.08
See NOTES previous page.
8
TC
22.90
17.10
13.40
26.60
20.10
16.80
29.30
22.20
19.60
28.60
20.30
15.90
34.30
24.40
20.00
38.40
27.90
23.70
33.80
24.00
19.30
39.60
28.60
24.10
43.60
32.20
28.30
42.30
30.30
23.80
49.30
36.30
29.90
54.80
40.90
35.20
46.30
34.10
26.70
54.00
40.30
33.40
60.00
44.90
39.20
58.00
41.70
32.50
65.80
48.30
38.90
72.30
53.70
44.70
50 (10)
SHC
11.80
12.60
13.40
14.10
15.60
16.80
16.00
18.20
19.60
14.60
15.10
15.90
17.80
18.80
20.00
20.40
22.20
23.70
17.40
18.30
19.30
20.90
22.60
24.10
23.70
26.50
28.30
21.60
22.60
23.80
25.90
28.10
29.90
29.50
32.80
35.20
23.70
25.20
26.70
28.50
31.20
33.40
32.50
36.30
39.20
29.60
30.80
32.50
34.10
36.60
38.90
38.20
41.80
44.70
BF
0.01
0.02
0.10
0.02
0.03
0.16
0.04
0.05
0.21
0.01
0.02
0.12
0.03
0.04
0.16
0.05
0.06
0.21
0.02
0.03
0.15
0.05
0.06
0.20
0.08
0.09
0.25
0.02
0.03
0.13
0.05
0.06
0.18
0.08
0.09
0.23
0.02
0.03
0.12
0.04
0.05
0.17
0.06
0.07
0.22
0.02
0.03
0.12
0.03
0.04
0.16
0.05
0.06
0.19
PERFORMANCE DATA (cont.)
COIL STATIC PRESSURE DROP (in. w.c.) PURONr AND R--22 REFRIGERANTS
2417
400
500
600
700
800
900
0.048 0.068 0.090 0.112 0.140 0.170
0.064 0.091 0.122 0.150 0.188 0.224
3017
0.042 0.060 0.080 0.102 0.128 0.157
0.055 0.076 0.104 0.127 0.158 0.190
3117
0.031 0.046 0.063 0.083 0.105 0.130
0.039 0.056 0.075 0.097 0.121 0.149
3617
0.043 0.061 0.082 0.103 0.128 0.157
0.056 0.079 0.107 0.133 0.166 0.200
4221
0.030 0.041 0.054 0.066 0.082 0.099
0.043 0.059 0.078 0.101 0.126 0.153
4321
0.040 0.052 0.066 0.081
0.049 0.062 0.079 0.096
4821
0.047 0.060 0.075 0.092
0.053 0.067 0.085 0.104
6024
0.062 0.073
0.082 0.096
6124
Standard CFM
1000 1100 1200 1300 1400
Dry
0.203
Wet
0.263
Dry
0.188 0.222 0.259
Wet
0.225 0.266 0.309
Dry
0.156 0.193 0.230
Wet
0.179 0.212 0.249
Dry
0.189 0.221 0.259 0.299 0.341
Wet
0.236 0.276 0.315 0.361 0.413
Dry
0.118 0.137 0.158 0.180 0.205
Wet
0.181 0.207 0.234 0.260 0.288
Dry
0.098 0.117 0.137 0.156 0.183
Wet
0.114 0.138 0.162 0.189 0.216
Dry
0.110 0.130 0.152 0.176 0.204
Wet
0.125 0.147 0.172 0.200 0.228
Dry
0.084 0.097 0.111 0.126 0.138
Wet
0.112 0.129 0.145 0.163 0.171
Dry
0.196
Wet
0.208
9
1500 1600 1700 1800 1900 2000 2100 2200
0.231 0.259
0.319 0.354
0.205 0.233
0.239 0.27
0.230 0.256 0.284 0.318
0.259 0.292 0.327 0.365
0.154 0.172 0.190 0.210 0.228 0.251 0.273 0.293
0.191 0.212 0.235 0.258 0.283 0.310 0.336 0.366
0.216 0.238 0.259 0.286 0.312 0.336 0.363 0.390
0.233 0.259 0.281 0.307 0.339 0.368 0.400 0.431
CNPHP / CNRHP
UNIT
SIZE
CNPHP / CNRHP
Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 02/12
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
10
Catalog No: CNPH ---05PD
Replaces: CNPH--- 4PD
Specification Data
Panasonic Ventilation Fan
Description
Ventilating fan shall be Low Noise ceiling mount type rated for continuous
operation. Fan shall be ENERGY STAR rated and certified by the Home
Ventilating Institute (HVI). Evaluated by the Underwriters Laboratories and
conform to both UL and cUL standards.
FV-08VQ5
(80 CFM)
Motor/Blower:
•
•
•
•
•
Four–pole totally enclosed condenser motor rated for continuous operation.
Power Rating shall be 120 volts and 60 Hz.
Fan shall be UL listed for tub/shower enclosure when used with
a GFCI branch circuit wiring.
Motor equipped with thermal–cutoff fuse.
Removable with permanently lubricated plug–in motor.
Housing:
•
•
•
•
•
Rust proof paint, galvanized steel body.
Detachable 4" diameter duct adapter.
Built in backdraft damper.
Expandable extension bracket up to 24".
Double hanger bar system allowing for ideal positioning.
Grille:
•
•
Attractive design using PP material.
Attaches directly to housing with torsion springs.
Warranty:
•
The factory warranty shall be a minimum of 3 years.
Ventilating fan shall be of the ceiling mount, ENERGY STAR rated type, with
no less than 80 CFM and no more than 0.3 sone as certified by the Home
Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge. Power
consumption shall be no greater than 14.7 watts and ENERGY STAR rated
with efficiency rating of no less than 5.8 CFM/watt. The motor shall be totally
enclosed, four pole condenser type engineered to operate continuously. Power
rating shall be 120v/60Hz. Duct diameter shall be no less than 4". Fan shall
be UL and cUL listed for tub/shower enclosure when used with GFCI branch
circuit wiring. Fan shall be ASHRAE 62.2, LEED, EarthCraft, California Title
24, ENERGY STAR IAP and WA Ventilation Code compliant.
4" Duct
(Standard)
FV-08VQ5
Static Pressure (inches w.g.)
0.1
Air Volume (CFM)
80
62
Fan Curve FV-08VQ5
0.60
0.50
0.40
FV-08VQ5
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
0.25
Ventilation Fan
Noise (sones)
<0.3
0.4
Characteristics
Power Consumption (Watts)
14.7
14.5
(HVI Certified
Energy Efficiency (CFM/Watts)
5.8
4.5
Speed (RPM)
829
1089
Current (amps)
0.12
0.12
Data)
Static Pressure(inch w.g.)
Typical Specifications:
Power Rating (V/Hz)
120/60
ENERGY STAR rated
Yes
As of 06/10
0.30
0.20
0.10
0.00
0
20
40
60
80
100
Airflow(CFM)
For Complete Installation Instructions Visit www.panasonic.com/building
Model
Quantity
Panasonic Home & Environment
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
| One Panasonic Way | Secaucus, NJ 07094 | 866-292-7292 | www.panasonic.com/building
59MN7A
Infinityr Modulating
4---Way Multipoise
Condensing Gas Furnace
Series 1
Product Data
A11263
The 59MN7A Multipoise Variable--Capacity Condensing Gas
Furnace features the modulating InfinityR System. The innovative
modulating gas valve is at the heart of this furnace’s quiet operation,
along with the variable--speed Infinity ECM blower motor and
variable--speed inducer motor. This furnace also provides 3.5 times
tighter temperature control than single stage furnaces. With an
Annual Fuel Utilization Efficiency (AFUE) up to 98.5%, this
Infinity gas furnace provides exceptional savings over standard
furnaces as well. This Infinity Gas Furnace also features 4--way
multipoise installation flexibility. The 59MN7A can be vented as a
direct vent/two--pipe furnace or as an optional ventilated
combustion air application. A Carrier InfinityR Control and an
Infinity Air Conditioner or Heat Pump can be used to form a
complete Infinity System. All units meet California Air Quality
Management District emission requirements. All sizes are design
certified in Canada.
STANDARD FEATURES
S Our quietest furnace. Compare for yourself at
HVACpartners.com.
S All sizes meet ENERGY STAR Version 4.0 criteria for gas
furnaces: 95+AFUE; AMACF electrical rating; 2% or less cabinet
airflow leakage.
S Supports single-- and multiple--zone Infinity systems.
S Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Infinity Features—match with the Infinity Control for Infinity
System benefits
S Integral part of the Ideal Humidity SystemR Technology.
S Silicon Nitride Power Heat Hot Surface Igniter.
S SmartEvap technology helps control humidity levels in the
home when used with a compatible humidity control system.
S ComfortFan technology allows control of continuous fan speed
from a compatible thermostat.
S External Media Filter Cabinet included.
S 4--way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through-the--cabinet downflow venting capability.
S Variable--Speed blower and inducer motors, modulating gas
valve.
S Self--diagnostics and extended diagnostic data through the
Advanced Product Monitor (APM) accessory or Infinity User
Interface.
S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized--steel primary heat exchanger.
S Stainless--steel condensing secondary heat exchanger.
S Propane convertible (See Accessory list).
S Factory--configured ready for upflow applications.
S Fully--insulated casing including blower section.
S Convenient Air Purifier and Humidifier connections.
S Direct--vent/sealed combustion or ventilated combustion air
venting.
S Installation flexibility: sidewall or vertical vent.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all present
air inlets, air outlets, and condensate drain port(s) sealed.
Always Ask For
CERTIFIED
1
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
CASING
DIMENSIONS (IN.)
SAP ORDERING NO.
H
D
W
RATED HEATING OUTPUT{
(BTUH)
Maximum
Minimum
AFUE
HEATING AIRFLOW
CFM‡
(Minimum
Heating)
CFM
(Maximum
Heating)
Rated Heating
ESP
@ Maximum
COOLING
CFM @ 0.5
ESP
MOTOR HP
(VARIABLE
SPEED)
59MN7A060V17--14
35 29.5 17.5
59,000
24,000
97.4%
415
1075
0.12
510 - 1335
1/2
59MN7A060V21--20
35 29.5 21.0
60,000
24,000
98.5%
555
1085
0.12
510 - 1905
1
59MN7A080V17--14
35 29.5 17.5
78,000
31,000
97.4%
620
1500
0.15
490 - 1375
1/2
59MN7A080V21--20
35 29.5 21.0
78,000
31,000
97.2%
620
1345
0.15
750 - 1945
1
59MN7A100V21--22
35 29.5 21.0
98,000
39,000
97.3%
725
1575
0.20
715 - 2160
1
59MN7A120V24--22
35 29.5 24.5
117,000
47,000
97.2%
900
1820
0.20
885 - 2185
1
{Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡Minimum heat CFM when low---heat rise adjustment switch (SW 1 ---3) and comfort/efficiency adjustment switch (SW1 ---4) on control center are OFF.
ESP --- External Static Pressure
59MN7A
FEATURES AND BENEFITS
Greenspeedt Intelligence — Adaptable-speed technology paired
with InfinityRintelligence, our new technology takes into account a
home owner’s complete comfort. It provides precise comfort by
adjusting the heating demands of the home. This translates into
reduced energy use and reduced temperature swings. Integrating
luxury-level comfort control into a home so smoothly and quietly,
you’ll forget it’s there.
Fully Modulating Gas Valve — When paired with the InfinityR
control, this furnace improves comfort by adjusting heating output
in 1% increments from 40% to 100% capacity to meet the heating
needs of the home. Precision begins with a stepper motor to adjust
manifold pressures. Stepper motors are used in electronic devices,
such as computer disc drives, which require precise mechanical
positioning. The precision of the stepper motor, combined with our
unique two-point calibration, allows the modulating furnace to
accurately control and directly deliver the right amount of gas to the
burners every time.
Ideal Humidity SystemR Technology — The Ideal Humidity
system actively controls both temperature and humidity in the home
to provide the best comfort all year long. Other systems depend on
heating or cooling demand to manage the moisture in the air. But,
Ideal Humidity gives the homeowner the right amount of humidity
day and night, even in mild weather. No other manufacturer can do
this! Ideal Humidity saves energy, too. By keeping humidity under
control, the homeowner can set their thermostat lower to stay
comfortable and save energy.
SmartEvapt Technology — When paired with a compatible
thermostat, this dehumidification feature overrides the cooling
blower off-delay when there is a call for dehumidification. By
deactivating the blower off-delay, SmartEvap technology prevents
condensate that remains on the coil after a dehumidification cycle
from re-humidifying throughout the home. This results in reduced
humidity and a more comfortable indoor environment for the
homeowner.
Unlike competitive systems, SmartEvap technology only overrides
the cooling when humidity control is needed. Once humidity is
back in control, SmartEvap re-enables the energy-saving cooling
blower off-delay.
ComfortFant Technology — Sometimes the constant fan setting
on a standard furnace system can actually reduce homeowner
comfort by providing too much or too little air! Comfort Fan
technology improves comfort all year long by allowing the
homeowner to select the continuous fan speed of their choice using
a compatible thermostat.
Power Heatt Igniter — Carrier’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Carrier’s tradition of
technology leadership and innovation in providing a reliable and
durable product.
Full-Featured, Communicating, Variable Speed Motors — Our
ECMs (Electronically Commutated Motors) provide variable-speed
operation to optimize comfort levels in the home year round;
MEDIA
CABINET
SUPPLIED
(IN.)
16
20
16
20
20
24
features such as passive/active dehumidification, ramping profiles,
constant air flow and quiet operation. They can provide cooling
match enhancements to increase the effective SEER of select Carrier
air conditioner or heat pump system, and feature the highest
efficiency of all indoor fan motors.
Reliable Heat Exchanger Design — The aluminized steel, clam
shell primary heat exchanger was re--engineered to achieve greater
efficiency out of a smaller size. The first two passes of the heat
exchanger are based on the current 80% product, a design with
more than ten years of field-proven performance and success. These
innovations, paired with the continuation of a crimped, no-weld
seam create an efficient, robust design for this essential component.
The condensing heat exchanger, a stainless steel fin and tube design,
is positioned in the furnace to extract additional heat. Stainless steel
coupling box componentry between heat exchangers has
exceptional corrosion resistance in both natural gas and propane
applications.
Media Filter Cabinet — Enhanced indoor air quality in the home
is made easier with our media filter cabinet—a standard accessory
on all deluxe furnaces. When installed as a part of the system, this
cabinet allows for easy and convenient addition of a Carrier high
efficiency air filter.
4-Way Multipoise Design — One model for all applications – there
is no need to stock special downflow or horizontal models when
one unit will do it all. The new heat exchanger design allows these
units to achieve the certified AFUE in all positions.
Direct Venting or Optional Ventilated Combustion Air — This
furnace can be installed as a 2-pipe (Direct Vent) furnace or as an
optional ventilated combustion air application. This provides added
flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion
air from outside the furnace, which results in especially quiet
operation. By sealing the entire combustion vestibule, the entire
furnace can be made quieter, not just the burners.
Insulated Casing — Foil-faced insulation in the heat exchanger
section of the casing minimizes heat loss. The acoustical insulation
in the blower compartment reduces air and motor noise for quiet
operation.
Monoport Burners — The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure — Factory-installed for side return; easily
removable for bottom return. The multi-use bottom closure can also
serve for roll-out protection in horizontal applications, and act as the
bottom closure for the optional return air base accessory.
Blower Access Panel Switch — Automatically shuts off 115-v
power to furnace whenever blower access panel is opened.
Quality Registration — Our furnaces are engineered and
manufactured under an ISO 9001 registered quality system.
Certifications — This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory--shipped for use with natural gas. A CSA listed gas conversion
kit is required to convert furnace for use with propane gas. The
efficiency is AHRI efficiency rating certified. This furnace meets
California Air Quality Management District emission requirements.
2
SPECIFICATIONS
(BTUH)
(BTUH)
(BTUH)
(BTUH)
(BTUH)
(BTUH)
Maximum Heat
Certified Temperature
Rise Range ºF (ºC)
Intermediate Heat
Minimum Heat
Airflow Capacity and Blower Data
Rated External Static
Pressure (in. w.c.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
Heating
Cooling
Maximum Heat
Intermediate Heat
Minimum Heat
Cooling
400 CFM/ton
350 CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
060-14
60,000
39,000
24,000
59,000
38,000
24,000
35 - 65
(19 - 36)
50 - 80
(28 - 44)
35 - 65
(19 - 36)
060-14
0.12
0.5
1075
530
415
1335
3
3.5
1/2
7.7
060-20
60,600
39,000
24,000
60,000
39,000
24,000
35 - 65
(19 - 36)
40 - 70
(22 - 39)
25 - 55
(14-31)
11 x 8
Electrical Data
Input Voltage
Volts-Hertz-Phase
Operating Voltage Range
Min-Max
Maximum Input Amps
Amps
Unit Ampacity
Amps
Minimum Wire Size
AWG
Feet
Maximum Wire Length
@ Minimum Wire Size
(M)
Maximum Fuse/Ckt Bkr
Amps
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
Heating
External Control Power
Available
Cooling
060-14
060-20
9.7
12.7
14
29
(8.8)
14.8
19.1
12
30
(9.1)
15
20
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
Manufacturer
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Manufactured (Mobile) Home Kit
Twinning Kit
Ignition Device
060-14
060-20
3
3
Filter Used for Certified Watt Data*
080-20
80,000
52,000
32,000
78,000
51,000
31,000
40 - 70
(22 - 39)
50 - 80
(28 - 44)
35 - 65
(19 - 36)
100-22
100,000
65,000
40,000
98,000
64,000
39,000
45 - 75
(25 - 42)
50 - 80
(28 - 44)
35 - 65
(19 - 36)
060-20
080-14
080-20
100-22
0.12
0.15
0.15
0.20
0.5
0.5
0.5
0.5
1080
1500
1345
1575
690
750
795
955
555
620
595
745
1905
1375
1945
2160
4.5
3.5
4.5
5.5
5.5
4
5.5
6
Electronically Commutated Motor (ECM)
1
1/2
1
1
12.8
7.7
12.8
12.8
300 - 1300
Variable (Communicating)
11 x 10
11 x 8
11 x 10
11 x 10
Factory Supplied Media Cabinet
Field Supplied Filter
KGAWF**06UFR
in.
Air Filtration System
080-14
80,000
52,000
32,000
78,000
51,000
31,000
40 - 70
(22 - 39)
50 - 80
(28 - 44)
35 - 65
(19 - 36)
080-14
080-20
115-60-1
104 -127
9.7
14.8
12.7
19.1
14
12
29
30
(8.8)
(9.1)
15
20
120-22
120,000
78,000
48,000
117,000
76,000
47,000
45 - 75
(25 - 42)
50 - 80
(28 - 44)
35 - 65
(19 - 36)
120-22
0.20
0.5
1820
1100
900
2185
5.5
6
1
12.8
11 x 11
100-22
120-22
14.8
19.1
12
30
(9.1)
14.8
19.1
12
30
(9.1)
20
20
100-22
120-22
5
6
40 VA
27.9 VA
34.6 VA
* See Accessory List for part numbers available.
3
080-14
080-20
1/2" - NPT
4
4
White Rogers
4.5
13.6
not approved for MH use
not approved for twinning
Silicon Nitride
59MN7A
Heating Capacity and Efficiency
Input
Maximum Heat
Intermediate Heat
Minimum Heat
Output
Maximum Heat
Intermediate Heat
Minimum Heat
SPECIFICATIONS (CONTINUED)
Controls
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections
060-14
180
060-20
080-14
080-20
100-22
160
170
200
180
Adjustable: 90, 120, 150, 180 seconds
90 seconds
Infinity; Infinity Zoning
R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
120-22
160
MODEL NUMBER NOMENCLATURE
Example of Model Number
1-2
Family
59
3
Htg. Stages
T
4
Tier
N
5
Base Effy.
6
6
Major Series
A
7-9
Htg. Cap.
11 - 12
Width
17
10
Motor
V
060
13
Voltage
--
14
Minor Series
--
08 - 800 CFM
10 - 1000 CFM
12 - 1200 CFM
14 - 1400 CFM
16 - 1600 CFM
18 - 1800 CFM
20 - 2000 CFM
22 - 2200 CFM
59MN7A
Family
S - Single Stage
T - Two Stage
M - Modulating
C - Comfort
P - Performance
N - Infinity
0 - +90 AFUE
2 - +92 AFUE
3 - +93 AFUE
5 - +95 AFUE
6 - +96 AFUE
7 - +97 AFUE
14 - 14.2”
17 - 17.5”
21 - 21.0”
24 - 24.5”
Major Series
15 - 16
Airflow
14
Minor Series
Voltage
040=40,000 BTU
060=60,000 BTU S - Standard
080=80,000 BTU E - Energy Efficient
100=100,000 BTU V - Variable Speed
120=120,000 BTU
140=140,000 BTU
Not all familes have these models.
A12373
FURNACE COMPONENTS
GAS BURNER
HOT SURFACE
IGNITER
MANUAL RESET
ROLLOUT SWITCH
FLAME
SENSOR
MANUAL RESET
ROLLOUT SWITCH
GAS VALVE
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
OPERATING INSTRUCTIONS
NOT SHOWN (LOCATED ON
MAIN FURNACE DOOR, SEE
OPERATING INSTRUCTIONS
INSIDE DOOR FIGURE).
INDUCER MOTOR
ASSEMBLY
ELECTRICAL JUNCTION
BOX (IF REQUIRED,
LOCATION MAY VARY)
BLOWER DOOR
SAFETY SWITCH
MEDIA CABINET
BLOWER AND
MOTOR
FURNACE
CONTROL
BOARD
CAPACITOR/
POWER CHOKE
(IF USED)
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
A11408
4
ACCESSORIES
PART NUMBER
Venting Accessories
Vent Kit - Through the Cabinet
KGADC0101BVC
Vent Terminal - Concentric - 2” (51 mm)
KGAVT0701CVT
Vent Terminal - Concentric - 3” (76 mm)
KGAVT0801CVT
Vent Terminal Bracket - 2” (51 mm)
KGAVT0101BRA
Vent Terminal Bracket - 3” (76 mm)
KGAVT0201BRA
Vent Kit --- Rubber Coupling
KGAAC0101RVC
Condensate Drainage Accessories
Freeze Protect Kit - Heat Tape
KGAHT0101CFP
CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVC
KGAAD0110PVC
Horizontal Trap Grommet - Direct Vent
KGACK0101HCK
Condensate Neutralizer Kit
P908--- 0001
External Trap Kit
KGAET0201ETK
Ductwork Adapter Accessories
Furnace Base Kit for Combustible Floors
KGASB0201ALL
Coil Adapter Kits --- No Offset
KGADA0101ALL
Coil Adapter Kits --- Single Offset
KGADA0201ALL
Coil Adapter Kits --- Double Offset
KGADA0301ALL
Return Air Base (Upflow Applications) 17.5--- in. wide
KGARP0301B17
Return Air Base (Upflow Applications) 21.0--- in. wide
KGARP0301B21
Return Air Base (Upflow Applications) 24.5--- in. wide
KGARP0301B24
IAQ Device Duct Adapters 20.0--- in. IAQ to 16 in. Side Return
KGAAD0101MEC
IAQ Device Duct Adapters 24.0--- in. IAQ to 16 in. Side Return
KGAAD0201MEC
Gas Conversion Accessories
Gas Conversion Kit - Nat to LP; Var-speed Products
KGANP5201VSP
Gas Conversion Kit - LP to Nat; Var-speed Products
KGAPN4401VSP
Gas Orifice Kit - #42 (Nat Gas)
LH32DB207
Gas Orifice Kit - #43 (Nat Gas)
LH32DB202
Gas Orifice Kit - #44 (Nat Gas)
LH32DB200
Gas Orifice Kit - #45 (Nat Gas)
LH32DB205
Gas Orifice Kit - #46 (Nat Gas)
LH32DB208
Gas Orifice Kit - #47 (Nat Gas)
LH32DB078
Gas Orifice Kit - #48 (Nat Gas)
LH32DB076
Gas Orifice Kit - #54 (LP)
LH32DB203
Gas Orifice Kit - #55 (LP)
LH32DB201
Gas Orifice Kit - #56 (LP)
LH32DB206
Gas Orifice Kit - 1.25mm (LP)
LH32DB209
Gas Orifice Kit - 1.30mm (LP)
LH32DB210
Control Accessories
ECM Motor Simulator Kit
KGBSD0301FMS
Advanced Product Monitor --- APM
KGASD0301APM
Infinity Touch Control --- Wi--- Fi
SYSTXCCITW01
Infinity Touch Control --- Non--- Wi--- Fi
SYSTXCCITN01
IAQ Accessories
Filter Pack (6 pack) --- Washable - 16x25x1 (406x635x25 mm)
KGAWF1306UFR
Filter Pack (6 pack) --- Washable - 24x25x1 (610x635x25 mm)
KGAWF1506UFR
EZ-Flex Filter - 16” (406 mm)
EXPXXFIL0016
EZ-Flex Filter - 20” (508 mm)
EXPXXFIL0020
EZ-Flex Filter - 24” (610 mm)
EXPXXFIL0024
EZ-Flex Filter with End Caps - 16” (406 mm)
EXPXXUNV0016
EZ-Flex Filter with End Caps - 20” (508 mm)
EXPXXUNV0020
EZ-Flex Filter with End Caps - 24” (610 mm)
EXPXXUNV0024
Cartridge Media Filter - 16” (406 mm)
FILXXCAR0016
Cartridge Media Filter - 20” (508 mm)
FILXXCAR0020
Cartridge Media Filter - 24” (610 mm)
FILXXCAR0024
Carrier Infinity Air Purifier - 16x25 (406x635 mm)
GAPAAXCC1625-A08
Carrier Infinity Air Purifier - 20x25 (508x635 mm)
GAPAAXCC2025-A08
GAPACCCAR1625-A05
Carrier Infinity Air Purifier Repl. Filter- 16x25 (406x635 mm)
GAPACCCAR2025-A05
Carrier Infinity Air Purifier Repl. Filter- 20x25 (508x635 mm)
Carrier Performance Air Purifier - 16x25 (508x635 mm)
PGAPXX1625
Carrier Performance Air Purifier - 20x25 (508x635 mm)
PGAPXX2025
Carrier Performance Air Purifier Repl Filter - 16x25 (406x635 mm) PGAPAXXCAR1625
Carrier Performance Air Purifier Repl. Filter - 20x25 (508x635
PGAPAXXCAR2025
mm)
D = Used with the model furnace
5
060-14 060-20 080-14 080-20 100-22 120-22
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
See Venting Tables
See Venting Tables
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
All DV Horizontal
D
D
D
D
D
D
D
D
D
D
D
20”x25” IAQ Devices
24”x25” IAQ Devices
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
Use with EZXCAB--- 1016
Use with EZXCAB--- 1020
Use with EZXCAB--- 1024
Use with EZXCAB--- 1016
Use with EZXCAB--- 1020
Use with EZXCAB--- 1024
Use with FILCABXL --- 1016
Use with FILCABXL --- 1020
Use with FILCABXL --- 1024
Up to 1600 CFM
Up to 2000 CFM
GAPAAXCC1625--- A08
GAPAAXCC2025--- A08
Up to 1600 CFM
Up to 2000 CFM
GAPAAXCC1625
D
D
GAPAAXCC2025
59MN7A
DESCRIPTION
AIR DELIVERY - CFM
Cooling4 and Heating Air Delivery -- CFM (Bottom Return5 With Filter)
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2)
59MN7A
Unit Size
Clg/CF Switch Settings
SWx-3
SWx-2
SWx-1
0.1
0.2
0.3
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1035
1025
1010
885
1050
1230
1230
1230
See note 4
See note 4
880
1035
1190
1190
1190
870
1025
1155
1155
1155
855
1010
1115
1115
1115
060-14
Clg Default:
OFF
OFF
OFF
1060
1070
1080
1080
1075
CF Default:
OFF
OFF
OFF
545
530
520
525
510
See note 4
Cooling (SW2)
Cont Fan (SW3)
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
545
710
875
1060
1235
1235
1235
530
710
880
1070
1240
1240
1240
520
710
890
1080
1250
1250
1250
525
695
895
1080
1255
1255
1255
510
690
895
1075
1255
1255
1255
890
1065
1250
1250
1250
1065
1050
Clg SW2:
Maximum Clg Airflow 2
1425
1425
1405
1370
1335
1300
1260
1225
1190
1155
Heating
(SW1)
Maximum Heat Airflow 3
Intermediate Heat Airflow 3
Minimum Heat Airflow 3
1075
535
420
1085
515
410
1095
505
415
1095
515
400
1090
495
380
1080
1065
1050
See note 4
See note 4
1035
1020
Clg/CF Switch Settings
SWx-3
SWx-2
SWx-1
0.1
0.2
0.3
0.8
0.9
1.0
1650
1625
1605
Unit Size
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
060-20
Clg Default:
OFF
OFF
OFF
1735
1735
1725
1715
1700
CF Default:
OFF
OFF
OFF
545
530
520
525
510
See note 4
Cooling (SW2)
Cont Fan (SW3)
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
540
680
925
1070
1215
1380
1735
525
725
915
1075
1245
1385
1735
525
725
910
1080
1235
1395
1725
520
720
895
1070
1220
1390
1715
540
720
900
1080
1220
1395
1700
890
1075
1210
1390
1685
875
1055
1200
1380
1665
See note 4
See note 4
865
1045
1195
1365
1650
860
1030
1185
1355
1625
855
1020
1175
1340
1605
1685
1665
Clg SW2:
Maximum Clg Airflow 2
1955
1950
1940
1925
1905
1885
1855
1815
1745
1685
Heating
(SW1)
Maximum Heat Airflow 3
Intermediate Heat Airflow 3
Minimum Heat Airflow 3
1080
685
560
1085
725
555
1095
730
555
1090
725
550
1095
730
565
1085
1070
1055
See note 4
See note 4
1045
1030
Clg/CF Switch Settings
SWx-3
SWx-2
SWx-1
0.1
0.2
0.3
0.8
0.9
1.0
1035
1025
1005
Unit Size
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
080-14
Clg Default:
OFF
OFF
OFF
1055
1065
1080
1075
1065
CF Default:
OFF
OFF
OFF
520
505
505
495
490
See note 4
Cooling (SW2)
Cont Fan (SW3)
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
520
665
885
1055
1245
1245
1245
505
685
895
1065
1245
1245
1245
505
680
905
1080
1255
1255
1255
495
660
900
1075
1255
1255
1255
490
665
900
1065
1260
1260
1260
895
1050
1255
1255
1255
885
1045
1250
1250
1250
See note 4
See note 4
875
1035
1235
1235
1235
860
1025
1220
1220
1220
845
1005
1185
1185
1185
1050
1045
Clg SW2:
Maximum Clg Airflow 2
1520
1485
1450
1415
1375
1335
1300
1265
1225
1190
Heating
(SW1)
Maximum Heat Airflow 3
Intermediate Heat Airflow 3
Minimum Heat Airflow 3
1520
755
620
1485
745
625
1450
755
630
1415
755
620
1375
765
610
1335
1300
1265
See note 4
See note 4
1225
1190
6
AIR DELIVERY -- CFM (CONTINUED)
Cooling4 and Heating Air Delivery -- CFM (Bottom Return5 With Filter)
Clg/CF Switch Settings
SWx-3
SWx-2
SWx-1
0.1
0.2
0.3
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1725
1705
1685
1095
1225
1400
1745
1745
See note 4
See note 4
1090
1220
1390
1725
1725
1080
1235
1390
1705
1705
1070
1235
1385
1685
1685
080-20
Clg Default:
OFF
OFF
OFF
1745
1755
1755
1760
1755
CF Default:
OFF
OFF
OFF
700
710
750
725
750
See note 4
Cooling (SW2)
Cont Fan (SW3)
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
700
830
1045
1215
1370
1745
1745
710
860
1045
1220
1370
1755
1755
750
870
1060
1245
1390
1755
1755
725
890
1070
1240
1390
1760
1760
750
960
1070
1235
1400
1755
1755
1070
1235
1395
1750
1750
1750
1745
Clg SW2:
Maximum Clg Airflow 2
1920
1920
1945
1945
1945
1960
1950
1940
1915
1900
Heating
(SW1)
Maximum Heat Airflow 3
Intermediate Heat Airflow 3
Minimum Heat Airflow 3
1340
780
595
1355
810
595
1370
835
600
1385
840
595
1380
845
605
1385
1400
1400
See note 4
See note 4
1385
1380
Clg/CF Switch Settings
SWx-3
SWx-2
SWx-1
0.1
0.2
0.3
0.8
0.9
1.0
1805
1780
1770
Unit Size
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
100-22
Clg Default:
OFF
OFF
OFF
1820
1825
1840
1845
1840
CF Default:
OFF
OFF
OFF
750
740
745
730
715
See note 4
Cooling (SW2)
Cont Fan (SW3)
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
750
900
1070
1280
1440
1820
2135
740
900
1075
1285
1445
1825
2140
745
915
1095
1305
1465
1840
2140
730
910
1095
1305
1465
1845
2135
715
905
1090
1310
1470
1840
2140
1085
1305
1485
1835
2130
1095
1295
1480
1825
2115
See note 4
See note 4
1080
1300
1485
1805
2100
1065
1290
1475
1780
2070
1070
1285
1460
1770
2015
Maximum Clg Airflow 2
2160
2165
2175
2170
2160
2150
2135
2120
2065
2020
Heating
(SW1)
Maximum Heat Airflow 3
Intermediate Heat Airflow 3
Minimum Heat Airflow 3
1570
950
755
1575
955
745
1595
965
750
1595
975
735
1600
970
720
1605
1600
See note 4
See note 4
1600
1590
1575
Clg/CF Switch Settings
SWx-3
SWx-2
SWx-1
0.1
0.2
0.3
0.8
0.9
1.0
1775
1750
1730
120-22 6
Clg Default:
CF Default:
Cooling (SW2)
Cont Fan (SW3)
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
OFF
OFF
OFF
1850
1855
1860
1855
1850
OFF
OFF
OFF
930
925
915
900
885
See note 4
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
765
930
1095
1265
1465
1850
2200
745
925
1100
1255
1455
1855
2200
740
915
1110
1265
1470
1860
2200
705
900
1105
1280
1465
1855
2190
680
885
1085
1275
1465
1850
2185
1285
1470
1830
2170
1270
1455
1805
2145
See note 4
See note 4
See note 4
1260
1450
1775
2085
1250
1435
1750
1990
1230
1415
1730
1890
4.
5.
6.
1830
1805
Clg SW2:
Maximum Clg Airflow 2
2200
2200
2200
2190
2185
2170
2145
2085
1990
1890
Heating
(SW1)
Maximum Heat Airflow 3
Intermediate Heat Airflow 3
1815
1095
1820
1100
1825
1110
1820
1105
1815
1085
1795
1775
1745
See note 4
1720
1700
1. Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW4-3 set to OFF.
3.
1825
Clg SW2:
Unit Size
2.
1835
Set SW1-5 to ON for nominal 400 CFM/ton (+15% airflow).
Set SW4-3 to ON for nominal 325 CFM/ton (-7% airflow).
Set both SW1-5 and SW4-3 to ON for nominal 370 CFM/ton (+7% airflow).
The above adjustments in airflow are subject to motor horsepower range/capacity.
Maximum cooling airflow is achieved when switches SW2-1, SW2-2, SW2-3 and SW1-5 are set to ON, and SW4-3 is set to OFF.
All heating CFM’s are when low/medium heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) are both
set to OFF.
Ductwork must be sized for high-heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not
recommended because high-heat operation will be above 1.0 ESP.
All airflows on 21” casing size furnaces are 5% less on side return only installations.
Side returns for 24.5” casing sizes require two sides, or side and bottom, to allow sufficient airflow at the return of the furnace.
7
59MN7A
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 and 2)
Unit Size
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - FT. / M
Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M)
Modulating
Furnace High
Heat Input
Winter Design
Temp ° F (° C)
20 (-10)
0 (-20)
60000
-20 (-30)
-40 (-40)
59MN7A
20 (-10)
0 (-20)
60600
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
80000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
100000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
120000
-20 (-30)
-40 (-40)
Pipe
Length in
Ft. & M
No Insulation
3/8-in. (9.5 mm)
1/2-in. (12.7 mm)
Pipe Diameter-inches (mm)
Pipe Diameter-inches (mm)
Pipe Diameter-inches (mm)
1.5
2.0
2.5
3.0
4.0
1.5
2.0
2.5
3.0
4.0
1.5
2.0
2.5
3.0
4.0
(38)
(51)
(64)
(76)
(102)
(38)
(51)
(64)
(76)
(102)
(38)
(51)
(64)
(76)
(102)
Ft.
34.0
29.0
28.0
23.0
N/A
55.0
88.0
79.0
69.0
N/A
55.0
104.0
93.0
81.0
N/A
M
10.4
8.8
8.5
7.0
N/A
16.8
26.8
24.1
21.0
N/A
16.8
31.7
28.3
24.7
N/A
Ft.
14.0
9.0
7.0
0.0
N/A
55.0
49.0
43.0
34.0
N/A
55.0
60.0
52.0
42.0
N/A
M
4.3
2.7
2.1
0.0
N/A
16.8
14.9
13.1
10.4
N/A
16.8
18.3
15.8
12.8
N/A
Ft.
5.0
0.0
0.0
0.0
N/A
41.0
32.0
26.0
18.0
N/A
50.0
40.0
33.0
24.0
N/A
M
1.5
0.0
0.0
0.0
N/A
12.5
9.8
7.9
5.5
N/A
15.2
12.2
10.1
7.3
N/A
Ft.
0.0
0.0
0.0
0.0
N/A
30.0
21.0
16.0
8.0
N/A
37.0
28.0
22.0
13.0
N/A
M
0.0
0.0
0.0
0.0
N/A
9.1
6.4
4.9
2.4
N/A
11.3
8.5
6.7
4.0
N/A
Ft.
34.0
29.0
28.0
23.0
N/A
55.0
88.0
79.0
69.0
N/A
55.0
104.0
93.0
81.0
N/A
M
10.4
8.8
8.5
7.0
N/A
16.8
26.8
24.1
21.0
N/A
16.8
31.7
28.3
24.7
N/A
Ft.
14.0
9.0
7.0
0.0
N/A
55.0
49.0
43.0
34.0
N/A
55.0
60.0
52.0
42.0
N/A
M
4.3
2.7
2.1
0.0
N/A
16.8
14.9
13.1
10.4
N/A
16.8
18.3
15.8
12.8
N/A
Ft.
5.0
0.0
0.0
0.0
N/A
41.0
32.0
26.0
18.0
N/A
50.0
40.0
33.0
24.0
N/A
M
1.5
0.0
0.0
0.0
N/A
12.5
9.8
7.9
5.5
N/A
15.2
12.2
10.1
7.3
N/A
Ft.
0.0
0.0
0.0
0.0
N/A
30.0
21.0
16.0
8.0
N/A
37.0
28.0
22.0
13.0
N/A
M
0.0
0.0
0.0
0.0
N/A
9.1
6.4
4.9
2.4
N/A
11.3
8.5
6.7
4.0
N/A
Ft.
35.0
39.0
39.0
33.0
25.0
35.0
118.0 107.0
92.0
76.0
35.0
130.0 125.0 109.0
90.0
M
10.7
11.9
11.9
10.1
7.6
10.7
36.0
32.6
28.0
23.2
10.7
39.6
38.1
33.2
27.4
Ft.
22.0
16.0
14.0
7.0
0.0
35.0
69.0
60.0
49.0
35.0
35.0
83.0
72.0
60.0
45.0
M
6.7
4.9
4.3
2.1
0.0
10.7
21.0
18.3
14.9
10.7
10.7
25.3
21.9
18.3
13.7
Ft.
11.0
5.0
2.0
0.0
0.0
35.0
46.0
39.0
29.0
16.0
35.0
57.0
48.0
37.0
23.0
M
3.4
1.5
0.6
0.0
0.0
10.7
14.0
11.9
8.8
4.9
10.7
17.4
14.6
11.3
7.0
Ft.
4.0
0.0
0.0
0.0
0.0
35.0
33.0
26.0
17.0
4.0
35.0
41.0
34.0
24.0
11.0
M
1.2
0.0
0.0
0.0
0.0
10.7
10.1
7.9
5.2
1.2
10.7
12.5
10.4
7.3
3.4
Ft.
N/A
47.0
47.0
41.0
32.0
N/A
50.0
110.0 112.0
93.0
N/A
50.0
110.0 132.0 110.0
M
N/A
14.3
14.3
12.5
9.8
N/A
15.2
33.5
34.1
28.3
N/A
15.2
33.5
40.2
33.5
Ft.
N/A
21.0
19.0
12.0
1.0
N/A
50.0
74.0
61.0
45.0
N/A
50.0
89.0
74.0
57.0
M
N/A
6.4
5.8
3.7
0.3
N/A
15.2
22.6
18.6
13.7
N/A
15.2
27.1
22.6
17.4
Ft.
N/A
8.0
6.0
0.0
0.0
N/A
50.0
49.0
38.0
23.0
N/A
50.0
60.0
48.0
32.0
M
N/A
2.4
1.8
0.0
0.0
N/A
15.2
14.9
11.6
7.0
N/A
15.2
18.3
14.6
9.8
Ft.
N/A
1.0
0.0
0.0
0.0
N/A
42.0
34.0
24.0
10.0
N/A
50.0
43.0
32.0
18.0
M
N/A
0.3
0.0
0.0
0.0
N/A
12.8
10.4
7.3
3.0
N/A
15.2
13.1
9.8
5.5
Ft.
N/A
N/A
15.0
49.0
40.0
N/A
N/A
15.0
100.0 111.0
N/A
N/A
15.0
100.0 131.0
M
N/A
N/A
4.6
14.9
12.2
N/A
N/A
4.6
30.5
33.8
N/A
N/A
4.6
30.5
39.9
Ft.
N/A
N/A
15.0
17.0
6.0
N/A
N/A
15.0
75.0
57.0
N/A
N/A
15.0
90.0
70.0
M
N/A
N/A
4.6
5.2
1.8
N/A
N/A
4.6
22.9
17.4
N/A
N/A
4.6
27.4
21.3
Ft.
N/A
N/A
10.0
2.0
0.0
N/A
N/A
15.0
48.0
32.0
N/A
N/A
15.0
59.0
42.0
M
N/A
N/A
3.0
0.6
0.0
N/A
N/A
4.6
14.6
9.8
N/A
N/A
4.6
18.0
12.8
Ft.
N/A
N/A
1.0
0.0
0.0
N/A
N/A
15.0
32.0
17.0
N/A
N/A
15.0
41.0
25.0
M
N/A
N/A
0.3
0.0
0.0
N/A
N/A
4.6
9.8
5.2
N/A
N/A
4.6
12.5
7.6
* Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe
length calculated from Table 1 or 3.
† Insulation thickness based on R value of 3.5 per in.
8
MAXIMUM EQUIVALENT VENT LENGTH - FT. (M)
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 1 – Maximum Equivalent Vent Length -- Ft. (M)
0 to 4500 Ft. (0 to 1370 M) Altitude
0 to 2000
(0 to 610)
2001 to 3000
(610 to 914)
3001 to 4000
(914 to 1219)
4001 to 4500
(1219 to 1370)
DIRECT VENT (2-PIPE) AND VENTILATED COMBUSTION AIR ONLY
Unit Size
BTU/Hr
Vent Pipe Diameter (in.)
1-1/2
60,000
55
80,000
35
100,000
NA
120,000
NA
2
2-1/2
3
4
(16.8)
135
(41.1)
235
(71.6)
265
(80.8)
(10.7)
130
(39.6)
175
(53.3)
235
(71.6)
265
(80.8)
50
(15.2)
110
(33.5)
235
(71.6)
265
(80.8)
15
(4.6)
100
(30.5)
250
(76.2)
NA
NA
60,000
45
(13.7)
127
(38.7)
222
(67.7)
250
(76.2)
80,000
30
(9.1)
90
(27.4)
165
(50.3)
222
(67.7)
249
(75.9)
40
(12.2)
104
(31.7)
223
(68.0)
250
(76.2)
11
(3.4)
93
(28.3)
237
100,000
NA
120,000
NA
60,000
40
80,000
25
100,000
NA
120,000
NA
60,000
35
80,000
23
100,000
NA
120,000
NA
NA
NA
(72.2)
(12.2)
119
(36.3)
210
(64.0)
235
(71.6)
(7.6)
85
(25.9)
155
(47.2)
210
(64.0)
232
(70.7)
40
(12.2)
98
(29.9)
211
(64.3)
236
(71.9)
8
(2.4)
86
(26.2)
224
NA
NA
(68.3)
(10.7)
115
(35.1)
204
(62.2)
228
(69.5)
(7.0)
85
(25.9)
150
(45.7)
202
(61.6)
224
(68.3)
40
(12.2)
94
(28.7)
205
(62.5)
229
(69.8)
83
(25.3)
217
(66.1)
NA
NA
NA
* See notes at end of venting tables.
*See Table 3 for altitudes over 4500 ft. (1370 M)
VENT TERMINAL CONFIGURATIONS
ELBOW CONFIGURATIONS
Concentric
Long
Medium
Mitered
Standard 2-in., 3-in., or
optional 4-in. termination.
A13110
Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
Pipe Diameter (in):
1-1/2
2
2-1/2
3
4
Mitered 90º Elbow
8
(2.4)
8
(2.4)
8
(2.4)
8
(2.4)
8
(2.4)
Medium Radius 90º Elbow
5
(1.5)
5
(1.5)
5
(1.5)
5
(1.5)
5
(1.5)
Long Radius 90º Elbow
3
(0.9)
3
(0.9)
3
(0.9)
3
(0.9)
3
(0.9)
Mitered 45º Elbow
4
(1.2)
4
(1.2)
4
(1.2)
4
(1.2)
4
(1.2)
Medium Radius 45º Elbow
2.5
(0.8)
2.5
(0.8)
2.5
(0.8)
2.5
(0.8)
2.5
(0.8)
Long Radius 45º Elbow
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
1.5
(0.5)
Tee
16
(4.9)
16
(4.9)
16
(4.9)
16
(4.9)
16
0
(0.0)
0
(0.0)
0
(0.0)
0
(0.0)
Concentric Vent Termination
Standard Vent Termination
NA
0
(0.0)
9
NA
0
(0.0)
(4.9)
NA
0
(0.0)
59MN7A
Altitude
FT (M)
Venting System Length Calculations
The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent
length of elbows used in the venting system from Table 2.
Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.
See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one
foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.
Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Tables 1 and 3.
Example 1
59MN7A
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M). Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a factory accessory concentric vent
kit.
Can this application use 2--in. (50 mm ND) PVC/ABS DWV vent piping?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
3
x
3 ft
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
2
x
1.5 ft
vent or inlet pipe)
Add equiv length of vent termination
100 ft
Use length of the longer of the vent
or air inlet piping system
=
9 ft.
From Table 2
=
3 ft.
From Table 2
0 ft.
Total Equivalent Vent Length (TEVL)
112 ft.
From Table 2
From Vent Manufacturer’s instructions;
zero for PVC/ABS DWV
Add all of the above lines
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
127 ft.
YES
For 2” pipe from Table 1
Therefore, 2” pipe may be used
Add correction for flexible vent pipe, if any
0 ft.
Example 2
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M) Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6 M)
of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.
Assume that one meter of flexible 60 mm or 80 mm polypropylene pipe equals 1.8 meters of PVC/ABS pipe. VERIFY FROM VENT
MANUFACTURER’S INSTRUCTIONS.
Can this application use 60 mm (O.D.) polypropylene vent piping? If not what size piping can be used?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
3
x
3 ft
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
0
x
vent or inlet pipe)
Add equiv length of of vent termination
9M
x 3 ft/M
Add correction for flexible vent pipe, if any
1.8
x
20 ft
Total Equivalent Vent Length (TEVL)
100 ft
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
=
9 ft.
From Vent Manufacturer’s instructions
=
0 ft.
From Vent Manufacturer’s instructions
=
=
18 ft.
36 ft.
163 ft.
From Vent Manufacturer’s instructions
From Vent Manufacturer’s instructions
Add all of the above lines
127 ft.
For 2” pipe from Table 1
Therefore, 60mm pipe may NOT be used;
try 80 mm
NO
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
250 ft.
YES
10
Use length of the longer of the vent
or air inlet piping system
For 3” pipe from Table 1
Therefore, 80 mm pipe may be used
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 3 – Maximum Equivalent Vent Length -- Ft. (M)
4501 to 10,000 Ft. (0 to 1370 M) Altitude
4501 to 5000
(1370 to 1524)
5001 to 6000
(1524 to 1829)
6001 to 7000
(1829 to 2134)
7001 to 8000
(2134 to 2438)
DIRECT VENT (2-PIPE) AND VENTILATED COMBUSTION AIR ONLY
Vent Pipe Diameter
Unit Size
1-1/2
60,000
35
80,000
23
100,000
NA
120,000
NA
9001 to 10,000
(2743 to 3048)
2-1/2
3
4
111
(33.8)
198
(60.4)
221
(67.4)
(7.0)
85
(25.9)
146
(44.5)
195
(59.4)
216
(65.8)
40
(12.2)
91
(27.7)
200
(61.0)
222
(67.7)
80
(24.4)
211
(64.3)
NA
NA
NA
60,000
37
(11.3)
103
(31.4)
186
(56.7)
207
(63.1)
80,000
22
(6.7)
76
(23.2)
137
(41.8)
183
(55.8)
200
(61.0)
33
(10.1)
85
(25.9)
188
(57.3)
208
(63.4)
74
(22.6)
199
100,000
NA
120,000
NA
60,000
35
80,000
20
100,000
NA
120,000
NA
60,000
32
80,000
18
100,000
NA
30
80,000
17
100,000
NA
120,000
NA
(60.7)
96
(29.3)
174
(53.0)
194
(59.1)
(6.1)
71
(21.6)
120
(36.6)
171
(52.1)
185
(56.4)
31
(9.4)
79
(24.1)
178
(54.3)
195
(59.4)
68
(20.7)
187
NA
NA
NA
(57.0)
(9.8)
89
(27.1)
163
(49.7)
181
(55.2)
(5.5)
66
(20.1)
120
(36.6)
159
(48.5)
170
(51.8)
29
(8.8)
73
(22.3)
167
(50.9)
182
(55.5)
175
NA
60,000
NA
NA
(10.7)
NA
120,000
8001 to 9000
(2438 to 2743)
2
(10.7)
NA
NA
NA
62
(18.9)
(9.1)
82
(25.0)
152
(46.3)
168
(51.2)
(5.2)
62
(18.9)
111
(33.8)
148
(45.1)
156
(47.5)
27
(8.2)
67
(20.4)
157
(47.9)
170
(51.8)
56
(17.1)
164
(50.0)
NA
NA
(53.3)
NA
60,000
27
(8.2)
76
(23.2)
142
(43.3)
156
(47.5)
80,000
15
(4.6)
57
(17.4)
103
(31.4)
137
(41.8)
142
(43.3)
24
(7.3)
62
(18.9)
147
(44.8)
157
(47.9)
51
(15.5)
153
(46.6)
100,000
NA
120,000
NA
NA
NA
NA
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
Use only the vent pipe sizes shown for each furnace. It is NOT necessary to choose the smallest diameter pipe possible for venting.
NA --- Not allowed. Pressure switch will not close, or flame disturbance may result.
Vent sizing for Canadian installations over 4500 ft. (1370 M) above sea level are subject to acceptance by the local authorities having jurisdiction.
Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
The minimum pipe length is 5 ft. (1.5 M) linear feet (meters) for all applications.
Use 3 ---in. (76 mm) diameter vent termination kit for installations requiring 4 ---in. (102 mm) diameter pipe.
11
59MN7A
Altitude
FT (M)
RETURN AIR TEMPERATURE
This furnace is designed for continuous return--air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C)
db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F (27_C) db. Failure to follow these
return air limits may affect reliability of heat exchangers, motors and controls.
80
/ 27˚C
60
/ 16˚C
59MN7A
SUPPLY AIR
A10490
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITION
Rear
Front (Combustion air openings in furnace and in structure)
Required for service**
All Sides of Supply Plenum**
Sides
Vent
Top of Furnace
CLEARANCE
0 (0 mm)
1 in. (25 mm)
24 in. (610 mm)*
1 in. (25 mm)
0 (0 mm)
0 (0 mm)
1 in. (25 mm)
* Recommended
**Consult your local building codes
VENTILATED COMBUSTION--AIR PIPE FOR ATTIC/CRAWLSPACE APPLICATIONS
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
MITERED RADIUS
PVC 90° ELBOW
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC PIPE
12” (300 mm) MINIMUM
A12376
NOTE: See Installation Instructions for specific venting configurations.
12
DOWNFLOW SUBBASE
LOCATING
TAB
1 1/4-IN. TYP
PLENUM
OPENING
B
A
D
1
2
3
4
LOCATING
TAB
C
4
A97427
3
2
1
A88207
Assembled
Disassembled
DIMENSIONS (IN. / MM)
PLENUM OPENING*
FLOOR OPENING
HOLE NO. FOR
WIDTH
ADJUSTMENT
FURNACE
CASING WIDTH
FURNACE IN DOWNFLOW
APPLICATION
B
C
D
17--- 1/2 (444.5)
Furnace with or without Cased Coil
Assembly or Coil Box
15--- 1/8
(384.2)
19 (482.6)
16--- 3/4
(425.5)
20--- 3/8
(517.5)
3
21 (533.4)
Furnace with or without Cased Coil
Assembly or Coil Box
18--- 5/8
(396.4)
19 (482.6)
20--- 1/4
(514.4)
20--- 3/8
(517.5)
2
24--- 1/2 (622.3)
Furnace with or without Cased Coil
Assembly or Coil Box
22--- 1/8
(562.0)
19 (482.6)
23--- 3/4
(603.3)
20--- 3/8
(517.5)
1
A
*The plenum should be constructed 1/4 ---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
Concentric Vent Kit
Downflow Subbase
A93086
A88202
A concentric vent kit allows vent and combustion--air pipes to
terminate through a single exit in a roof or side wall. One pipe runs
inside the other allowing venting through the inner pipe and
combustion air to be drawn in through the outer pipe.
One base fits all furnace sizes. The base is designed to be installed
between the furnace and a combustible floor when no coil box is
used or when a coil box other than a Carrier cased coil is used. It is
CSA design certified for use with Carrier branded furnaces when
installed in downflow applications.
13
59MN7A
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
MEDIA FILTER CABINET
25-5/8"
(651mm)
24-1/4”
(616mm)
Opening with Flanges Bent
23-1/8”
(588mm)
Opening
23-5/8"
(600mm)
23-3/8”
(594mm)
B Opening
59MN7A
A
Duct Side
Furnace Side
23-3/4”
(603mm)
Centerline Screw Slots
5 3 4"
(146mm)
Media Filter
A
B
Cabinet
16" (406mm) 17" (432mm) 16" (406mm)
20" (508mm) 21" (533mm) 20" (508mm)
24" (610mm) 25" (635mm) 24" (610mm)
NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return.
A12428
TYPICAL WIRING SCHEMATIC
FIELD 24-VOLT WIRING
FIELD 115-, 208/230-, 460-VOLT WIRING
FACTORY 24-VOLT WIRING
FACTORY 115-VOLT WIRING
NOTE 2
W
FIVE
WIRE
BLOWER
DOOR
SWITCH
BLK
Y
R
G
1-STAGE
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
FUSED DISCONNECT
THREE-WIRE
HEATINGONLY
BLK
WHT
C
WHT
GND
115-VOLT FIELD- JUNCTION
SUPPLIED
BOX
FUSED
DISCONNECT
C
O
N
T
R
O
L
208/230- OR
460-VOLT
THREE
PHASE
W2
COM
W/W1
Y/Y2
NOTE 1
R
GND
CONDENSING
UNIT
G
24-VOLT
TERMINAL
BLOCK
FURNACE
208/230VOLT
SINGLE
PHASE
NOTES: 1. Connect Y/Y2-terminal as shown for proper operation.
2. Some thermostats require a "C" terminal connection as shown.
3. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
A11401
14
59MN7
FURNACE SIZE
060--- 14
080--- 14
060--- 20
080--- 20
100--- 22
120--- 22
25 1/8
[638.7]
15
A
CABINET WIDTH
B
OUTLET WIDTH
C
BOTTOM INLET WIDTH
D
AIR INTAKE
17--- 1/2 (445)
15--- 7/8 (403)
16 (406)
8--- 3/4 (222)
21 (533)
19--- 3/8 (492)
19--- 1/2 (495)
10--- 1/2 (267)
24--- 1/2 (622)
22--- 7/8 (581)
23 (584)
12--- 1/4 (311)
21
[534.0]
26 5/16
[668.8]
22
[558.3] (BOTH SIDES)
1 (BOTH SIDES)
[25.4]
7/8
[22.2]
THERMOSTAT ENTRY
SIDE INLET
2 1/2
[63.5]
7/8
[22.2]
7/8
[22.2]
7/8
[22.2]
4
[101.6]
CONDENSATE DRAIN TRAP
LOCATION
AIR FLOW
19 1/8
[485.8]
20 5/8
[522.7]
23 5/16
[592.9]
26 3/8
[670.0]
26 11/16
[678.1]
TOP VIEW
6 11/16
[170.1]
6 15/16
[176.1]
D
SEE NOTE #3
14 13/16
[376.3]
16 9/16
[420.9]
17 5/16
[439.2]
7/8
[22.2] POWER CONN
3
[76.2]
VENT
1 3/4
[44.5]
GAS CONN
3
[76.2]
AIR INTAKE
3
[76.2]
AIR INTAKE
3
[76.2]
VENT
2 3/10
[58.4]
23 7/16
[595.6] 25 3/16
[639.1]
22 15/16
[581.9]
20 1/4
[513.9]
28 5/8
[726.4]
28 3/16
[715.9]
11/16
[17.5]
32 5/8
[829.5]
5/8
[15.8]
NOTE: ALL DIMENSIONS IN INCH [MM]
C
BOTTOM RETURN
WIDTH
AIR FLOW
B
OUTLET WIDTH
A
59MN7A
2 1/2
[63.5]
1 5/16
[33.3]
6 1/16
[154.0]
16 9/16
[420.9]
17 7/16
[442.3]
20 1/4
[513.9] 18 1/16
[458.6]
24
[609.7]
28 3/8
[720.4]
28 5/8
[726.9]
29 13/16
[757]
11/16
[17.5]
35
[889.0]
3
[76.2 ]
3
[76.2]
AIR INTAKE
2
NEXT SHEET
SD5024-4
PART NUMBER
7/8
[22.2]
4
[101.6]
SIDE INLET
7/8
[22.2] POWER CONN
7/8
[22.2]
1 3/4
[44.5]
GAS CONN
7/8
[22.2]
AIR FLOW
20 5/8
[522.7]
21 1/16
[535.8]
21 15/16
[557.4]
26 3/8
[669.9]
26 11/16
[678.1]
28 3/4
[730.5]
29 1/2
[749.3]
REV
E
SHT
1
BOTTOM INLET
21 5/8
[549.5]
23 3/8
[592.0]
26 5/16
[668.8]
7/8
[22.2]
THERMOSTAT ENTRY
NOTES:
1. Doors may vary by model.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle.
b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle.
c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle.
d. Return air above 1800 CFM at 0.5 in. w.c. ESP on 24.5" casing, requires one of the following
configurations: 2 sides, 1 side and a bottom or bottom only. See Air Delivery table in this
document for specific use to allow for sufficient airflow to the furnace.
3. Vent and Combustion air pipes through blower compartment must
use accessory “Vent Kit - Through the Cabinet”. See accessory list for
current part number.
DIMENSIONAL DRAWING
A12267
SHIP WT. --- LB (KG)
154.0 (69.3)
164.0 (73.8)
158.5 (72.0)
168.5 (76.6)
178.5 (80.3)
202.5 (91.1)
GUIDE SPECIFICATIONS
General
System Description
Furnish a ______________________ 4--way multipoise
modulating gas--fired condensing furnace for use with natural gas or
propane (factory-- authorized conversion kit required for propane);
furnish external media cabinet for use with accessory media filter or
standard filter.
59MN7A
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue StarR and Blue FlameR labels. Unit
efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy Guide
efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed ball bearings, of _______hp,
and have infinitely variable speed from 300--1300 RPM operating
only when motor inputs are provided. Blower motor shall be direct
drive and soft mounted to the blower housing to reduce vibration
transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted steel.
Draft Inducer Motor
Draft inducer motor shall be variable--speed design.
Copyright 2014 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass corrosion-- resistant
aluminized steel of fold--and--crimp sectional design and applied
operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a stainless steel flow--through
of fin--and--tube design and applied operating under negative
pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace, and a
replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including separate blower speeds for
all modulating heating capacities, low cooling, high cooling and
continuous fan. Continuous fan speed may be adjusted from the
thermostat. Cooling airflow will be selectable between 325 to 400
CFM per ton of air conditioning. Features will also include
temporary reduced airflow in the cooling mode for improved
dehumidification when an Infinity Control or TP--PRH edgeR is
selected as the thermostat.
Operating Characteristics
Heating capacity shall be _________________ Btuh input;
______________ Btuh output capacity.
Fuel Gas Efficiency shall be __________ AFUE.
Air delivery shall be ________________ cfm minimum at 0.50 in.
W.C. external static pressure.
Dimensions shall be: depth_________in. (mm); width
__________in. (mm); height___________in. (mm) (casing only).
Height shall be _________in. (mm) with A/C coil and
_________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size of
HACR--type designated circuit breaker shall be _________ amps.
Special Features
Refer to section of the product data identifying accessories and
descriptions for specific features and available enhancements.
Edition Date: 05/14
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
16
Catalog No: 59MN7A ---05PD
Replaces: 59MN7A--- 04PD
59TP6A
Performance Two---Stage, Variable Speed
4---Way Multipoise
Condensing Gas Furnace
Series 1
Product Data
A11263
The 59TP6A Multipoise Variable--Speed Condensing Gas Furnace
features the two--stage Performancet System. The Comfort HeatR
technology two--stage gas valve is at the heart of the comfort
provided by this furnace, along with the variable--speed ECM
blower motor, and two--speed inducer motor. With an Annual Fuel
Utilization Efficiency (AFUE) up to 96.5%, the Performancet
Series two--stage gas furnace provides exceptional savings when
compared to standard gas furnaces. This Performance Gas Furnace
also features 4--way multipoise installation flexibility, and is
available in eight model sizes. The 59TP6A can be vented for
direct vent/two--pipe, ventilated combustion air, or single--pipe
applications. All units meet California Air Quality Management
District emission requirements. All sizes are design certified in
Canada.
STANDARD FEATURES
S All sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+AFUE; AMACF electrical rating; 2% or less
cabinet airflow leakage.
S Quiet operation. Compare for yourself at HVACpartners.com.
S Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Silicon Nitride Perfect Light Hot Surface Igniter.
S SmartEvap technology helps control humidity levels in the
home when used with a compatible humidity control system.
S ComfortFan technology allows control of continuous fan
speed from a compatible thermostat.
S 4--way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through-the--cabinet downflow venting capability.
S Full--featured variable--speed blower motor, two--speed inducer
motor, and two--stage gas valve.
S Self--diagnostics.
S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized--steel primary heat exchanger.
S Stainless--steel condensing secondary heat exchanger.
S Propane convertible (See Accessory list).
S Factory--configured ready for upflow applications.
S Fully--insulated casing including blower section.
S Convenient Air Purifier and Humidifier connections.
S Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.
S Installation flexibility: sidewall or vertical vent.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
TM
1
CASING
DIMENSIONS
(IN.)
SAP ORDERING
NO.
59TP6A040E141110
59TP6A040E171112
59TP6A060E141112
59TP6A060E171114
59TP6A080E171116
59TP6A080E211120
59TP6A100E211120
59TP6A120E241122
RATED HEATING OUTPUT†
(BTUH)
HEATING AIRFLOW
H
D
W
High
Low
AFUE
CFM‡ (High
Heating
CFM (Low
Heating)
High Heating
ESP
(in. W.C.)
35
35
35
35
35
35
35
35
29.5
29.5
29.5
29.5
29.5
29.5
29.5
29.5
14.2
17.5
14.2
17.5
17.5
21.0
21.0
24.0
39,000
39,000
58,000
58,000
78,000
78,000
97,000
117,000
25,000
25,000
38,000
38,000
50,000
51,000
63,000
76,000
96.5%
96.0%
95.0%
96.3%
96.2%
96.5%
96.1%
96.5%
815
860
1120
1135
1505
1555
1865
2375
660
660
910
860
1160
1200
1435
1675
0.10
0.10
0.12
0.12
0.15
0.15
0.20
0.20
COOLING
CFM @ 0.5
ESP
(in. W.C.)
MOTOR HP SPEED
(VARIABLE
SPEED)
905
1065
1065
1475
1610
2005
2005
2115
1/2
1/2
1/2
3/4
3/4
1
1
1
59TP6A
{Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡Minimum heat CFM when low---heat rise adjustment switch (SW 1 ---3) and comfort/efficiency adjustment switch (SW1 ---4) on control center are OFF.
ESP --- External Static Pressure
FEATURES AND BENEFITS
Comfort Heat TechnologyR — This feature with Adaptive
Control is a proprietary function that promotes homeowner
comfort through two stages of heating. This Carrier furnace offers a
patented algorithm that continually monitors and adjusts furnace
operation by looking at both current and past conditions to
determine the most effective stage of heating and the amount of
time to run each stage, every cycle.
SmartEvapt Technology — When paired with a compatible
thermostat, this dehumidification feature overrides the cooling
blower off-delay when there is a call for dehumidification. By
deactivating the blower off-delay, SmartEvap technology prevents
condensate that remains on the coil after a dehumidification cycle
from re-humidifying throughout the home. This results in reduced
humidity and a more comfortable indoor environment for the
homeowner.
Unlike competitive systems, SmartEvap technology only overrides
the cooling blower off delay when humidity control is needed.
Once humidity is back in control, SmartEvap re-enables the
energy-saving cooling blower off-delay.
ComfortFant Technology — Sometimes the constant fan setting
on a standard furnace system can actually reduce homeowner
comfort by providing too much or too little air! Fan On Plus
technology improves comfort all year long by allowing the
homeowner to select the continuous fan speed of their choice using
a compatible thermostat.
HYBRID HEATR Dual Fuel system — This system can provide
more control over your monthly energy bills by automatically
selecting the most economical method of heating. With HYBRID
HEAT, our system automatically switches between the gas furnace
and the electric heat pump as outside temperatures change to
maintain greater efficiency and comfort than with any traditional
single-source heating system. The heat pump also delivers
high-efficiency cooling in the summer.
Power Heatt Igniter — Carrier’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Carrier’s tradition of
technology leadership and innovation in providing a reliable and
durable product.
Full-Featured, Variable Speed Motors — Our variable--speed
ECM (Electronically Commutated Motor) optimizes comfort levels
in the home year round; features such as passive/active
dehumidification, ramping profiles, and quiet operation. They can
provide cooling match enhancements to increase the effective
SEER of select Carrier air conditioner or heat pump system. This
motor does not report back RPM and static pressure to enable static
pressure reporting to the UI or zoning system, which is required for
zoning, active filter monitoring and system static pressure
reporting.
Reliable Heat Exchanger Design — The aluminized steel, clam
shell primary heat exchanger was re--engineered to achieve greater
efficiency out of a smaller size. The first two passes of the heat
exchanger are based on the current 80% product, a design with
more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential
component.
The condensing heat exchanger, a stainless steel fin and tube
design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and
propane applications.
Optional Media Filter Cabinet — Enhanced indoor air quality in
the home is made easier with our media filter cabinet When
installed as a part of the system, this cabinet allows for easy and
convenient addition of a Carrier high efficiency air filter.
4-Way Multipoise Design — One model for all applications –
there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated
Combustion Air — This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air
application, or in single-pipe, non-direct vent applications. This
provides added flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion
air from outside the furnace, which results in especially quiet
operation. By sealing the entire combustion vestibule, the entire
furnace can be made quieter, not just the burners.
Insulated Casing — Foil-faced insulation in heat exchanger
section of the casing minimizes heat loss. The acoustical insulation
in the blower compartment reduces air and motor noise for quiet
operation.
Monoport Burners — The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure — Factory--installed for side return; easily
removable for bottom return. The multi-use bottom closure can
also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.
Certifications — This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory--shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
gas. The efficiency is AHRI efficiency rating certified. This furnace
meets California Air Quality Management District emission
requirements.
2
MODEL NUMBER NOMENCLATURE
Example of Model Number
59
3
Htg. Stages
T
4
Tier
P
5
Base Effy.
6
6
Major Series
A
7-9
Htg. Cap.
11 - 12
Width
14
10
Motor
E
040
13
Voltage
--
14
Minor Series
--
08 - 800 CFM
10 - 1000 CFM
12 - 1200 CFM
14 - 1400 CFM
16 - 1600 CFM
18 - 1800 CFM
20 - 2000 CFM
22 - 2200 CFM
Family
S - Single Stage
T - Two Stage
M - Modulating
C - Comfort
P - Performance
N - Infinity
0 - +90 AFUE
2 - +92 AFUE
3 - +93 AFUE
5 - +95 AFUE
6 - +96 AFUE
7 - +97 AFUE
14 - 14.2”
17 - 17.5”
21 - 21.0”
24 - 24.5”
Major Series
15 - 16
Airflow
10
Minor Series
Voltage
040=40,000 BTU
060=60,000 BTU S - Standard
080=80,000 BTU E - Energy Efficient
100=100,000 BTU V - Variable Speed
120=120,000 BTU
140=140,000 BTU
Not all familes have these models.
A14368
FURNACE COMPONENTS
GAS BURNER
HOT SURFACE
IGNITER
MANUAL RESET
ROLLOUT SWITCH
FLAME
SENSOR
MANUAL RESET
ROLLOUT SWITCH
GAS VALVE
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
OPERATING INSTRUCTIONS
NOT SHOWN (LOCATED ON
MAIN FURNACE DOOR, SEE
OPERATING INSTRUCTIONS
INSIDE DOOR FIGURE).
INDUCER MOTOR
ASSEMBLY
ELECTRICAL JUNCTION
BOX (IF REQUIRED,
LOCATION MAY VARY)
BLOWER DOOR
SAFETY SWITCH
MEDIA CABINET
BLOWER AND
MOTOR
FURNACE
CONTROL
BOARD
CAPACITOR/
POWER CHOKE
(IF USED)
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
A11408
3
59TP6A
1-2
Family
SPECIFICATIONS
Heating Capacity and Efficiency
High Heat
Input
Low Heat
High Heat
Output
Low Heat
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data
Rated External Static
Pressure (in. w.c.)
59TP6A
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor Type
Direct-Drive Motor HP
Motor Full Load Amps
RPM Range
Speed Selections
Blower Wheel Dia x Width
(BTUH)
(BTUH)
(BTUH)
(BTUH)
High Heat
Low Heat
Heating
Cooling
High Heat
Low Heat
Cooling
400 CFM/ton
350 CFM/ton
040-10 040-12 060-12 060-14 080-16 080-20 100-20 120-22
40,000
40,000
60,000
60,000
80,000
80,000 100,000 120,000
26,000
26,000
39,000
39,000
52,000
52,000
65,000
78,000
39,000
39,000
58,000
58,000
78,000
78,000
97,000 117,000
25,000
25,000
38,000
38,000
50,000
51,000
63,000
76,000
40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70 40 - 70
(22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39) (22 - 39)
30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60 30 - 60
(17 - 33) (17 - 33) (17 - 33) (17 - 33) (17 - 33) (17 - 33) (17 - 33) (17 - 33)
040-10
0.10
0.5
815
660
905
2
2.5
1/2
6.8
in.
11 x 7
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data
Input Voltage
Operating Voltage Range
Maximum Input Amps
Unit Ampacity
Minimum Wire Size
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)
External Control Power
Available
040-12
0.10
0.5
860
660
1065
2.5
3
060-12 060-14 080-16 080-20
0.12
0.12
0.15
0.15
0.5
0.5
0.5
0.5
1120
1135
1505
1555
910
860
1160
1200
1065
1475
1610
2005
2.5
3.5
4
5
3
4
4.5
5.5
Electronically Communicated Motor (ECM)
1/2
1/2
3/4
3/4
1
6.8
6.8
8.4
8.4
10.9
600 - 1200
Variable (PWM)
11 x 8
11 x 7
11 x 8
11 x 8
11 x 10
Optional Media Cabinet
Field Supplied Filter
KGAWF1506UFR
040-10
040-12
060-12
Volts-Hertz-Phase
Min-Max
Amps
Amps
AWG
Feet
(M)
7.5
10.3
14
36
(11.0)
7.5
10.2
14
36
(11.0)
7.6
10.3
14
36
(11.0)
Amps
15
15
15
Manufacturer
Minimum Inlet Gas pressure (in. wc)
Maximum Inlet Gas pressure (in. wc)
Manufactured (Mobile) Home Kit
Ignition Device
Limit Control
Heating Blower Control (Heating Off-Delay)
Cooling Blower Control (Time Delay Relay)
Communication System
Thermostat Connections
Accessory Connections
15
15
120-22
0.20
0.5
2375
1675
2115
5
6
1
10.9
1
10.9
11 x 10
11 x 11
080-20
100-20
120-22
11.7
15.5
12
37
(11.3)
11.8
15.6
12
36
(11.0)
11.8
15.6
12
36
(11.0)
20
20
20
40 VA
24.3 VA
34.6 VA
Heating
Cooling
Controls
Gas Connection Size
Burners (Monoport)
Gas Valve (Redundant)
060-14 080-16
115-60-1
104-127
9.2
9.2
12.4
12.4
14
14
29
29
(8.8)
(8.8)
100-20
0.20
0.5
1865
1435
2005
5
5.5
040-10
2
165
040-12
060-14 080-16 080-20 100-20
1/2" - NPT
2
3
3
4
4
5
White Rodgers
4.5
13.6
not approved for MH use
Silicon Nitride
180
165
180
170
200
180
Adjustable: 90, 120, 150, 180 seconds
90 seconds
None
R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM
EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
* See Accessory List for part numbers available.
4
060-12
120-22
6
160
ACCESSORIES
PART NUMBER
040--- 10 040--- 12 060--- 12 060--- 14 080--- 16 080--- 20 100--- 20 120--- 22
KGADC0101BVC
KGAVT0701CVT
KGAVT0801CVT
KGAVT0101BRA
KGAVT0201BRA
KGAAC0101RVC
D
KGAHT0101CFP
KGAAD0110PVC
KGACK0101HCK
P908 ---0001
KGAET0201ETK
D
D
D
D
D
D
D
D
D
D
D
D
KGASB0201ALL
KGADA0101ALL
KGADA0201ALL
KGADA0301ALL
KGARP0301B14
KGARP0301B17
KGARP0301B21
KGARP0301B24
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
See Venting Tables
See Venting Tables
D
D
D
D
All DV Horizontal
D
D
D
D
D
KGAAD0101MEC
20”x25” IAQ Devices
KGAAD0201MEC
24”x25” IAQ Devices
KGCNP5201VSP
KGCPN4401VSP
LH32DB207
LH32DB202
LH32DB200
LH32DB205
LH32DB208
LH32DB078
LH32DB076
LH32DB203
LH32DB201
LH32DB206
LH32DB209
LH32DB210
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
T6 ---PRH01 ---A
KGATW0801HSI
D
D
D
D
D
D
D
D
D
D
D
D
KGAWF1306UFR
D
D
D
D
D
D
D
D
KGAWF1506UFR
D
D
D
D
D
D
D
D
EXPXXFIL0016
EXPXXFIL0020
EXPXXFIL0024
EXPXXUNV0016
EXPXXUNV0020
EXPXXUNV0024
FILXXCAR0016
FILXXCAR0020
FILXXCAR0024
GAPAAXCC1625-A08
GAPAAXCC2025-A08
Use with EZXCAB---1016
Use with EZXCAB---1020
Use with EZXCAB---1024
Use with EZXCAB---1016
Use with EZXCAB---1020
Use with EZXCAB---1024
Use with FILCABXL ---1016
Use with FILCABXL ---1020
Use with FILCABXL ---1024
Up to 1600 CFM
Up to 2000 CFM
GAPACCCAR1625-A05
Use with GAPAAXCC1625
GAPACCCAR2025-A05
Use with GAPAAXCC2025
PGAPXX1625
Up to 1600 CFM
PGAPXX2025
Up to 2000 CFM
PGAPAXXCAR1625
Use with PGAPXX1625
PGAPAXXCAR2025
Use with PGAPXX2025
5
59TP6A
DESCRIPTION
Venting Accessories
Vent Kit - Through the Cabinet
Vent Terminal - Concentric - 2” (51 mm)
Vent Terminal - Concentric - 3” (76 mm)
Vent Terminal Bracket - 2” (51 mm)
Vent Terminal Bracket - 3” (76 mm)
Vent Kit --- Rubber Coupling
Condensate Drainage Accessories
Freeze Protect Kit - Heat Tape
CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVC
Horizontal Trap Grommet - Direct Vent
Condensate Neutralizer Kit
External Trap Kit
Ductwork Adapter Accessories
Furnace Base Kit for Combustible Floors
Coil Adapter Kits --- No Offset
Coil Adapter Kits --- Single Offset
Coil Adapter Kits --- Double Offset
Return Air Base (Upflow Applications) 14.0 ---in. wide
Return Air Base (Upflow Applications) 17.5 ---in. wide
Return Air Base (Upflow Applications) 21.0 ---in. wide
Return Air Base (Upflow Applications) 24.5 ---in. wide
IAQ Device Duct Adapters 20.0 ---in. IAQ to 16 in. Side
Return
IAQ Device Duct Adapters 24.0 ---in. IAQ to 16 in. Side
Return
Gas Conversion Accessories
Gas Conversion Kit - Nat to LP; Var-speed Products
Gas Conversion Kit - LP to Nat; Var-speed Products
Gas Orifice Kit - #42 (Nat Gas)
Gas Orifice Kit - #43 (Nat Gas)
Gas Orifice Kit - #44 (Nat Gas)
Gas Orifice Kit - #45 (Nat Gas)
Gas Orifice Kit - #46 (Nat Gas)
Gas Orifice Kit - #47 (Nat Gas)
Gas Orifice Kit - #48 (Nat Gas)
Gas Orifice Kit - #54 (LP)
Gas Orifice Kit - #55 (LP)
Gas Orifice Kit - #56 (LP)
Gas Orifice Kit - 1.25mm (LP)
Gas Orifice Kit - 1.30mm (LP)
Control Accessories
PerformanceR Series EdgeR Thermostat
Twinning Kit
IAQ Accessories
Filter Pack (6 pack) --- Washable - 16x25x1
(406x635x25 mm)
Filter Pack (6 pack) --- Washable - 24x25x1
(610x635x25 mm)
EZ-Flex Filter - 16” (406 mm)
EZ-Flex Filter - 20” (508 mm)
EZ-Flex Filter - 24” (610 mm)
EZ-Flex Filter with End Caps - 16” (406 mm)
EZ-Flex Filter with End Caps - 20” (508 mm)
EZ-Flex Filter with End Caps - 24” (610 mm)
Cartridge Media Filter - 16” (406 mm)
Cartridge Media Filter - 20” (508 mm)
Cartridge Media Filter - 24” (610 mm)
Carrier Infinity Air Purifier - 16x25 (406x635 mm)
Carrier Infinity Air Purifier - 20x25 (508x635 mm)
Carrier Infinity Air Purifier Repl. Filter- 16x25
(406x635 mm)
Carrier Infinity Air Purifier Repl. Filter- 20x25
(508x635 mm)
Carrier Performance Air Purifier - 16x25 (508x635
mm)
Carrier Performance Air Purifier - 20x25 (508x635
mm)
Carrier Performance Air Purifier Repl Filter - 16x25
(406x635 mm)
Carrier Performance Air Purifier Repl. Filter - 20x25
(508x635 mm)
D = Used with the model furnace
AIR DELIVERY - CFM
Unit Size
040---10
Clg Default:
59TP6A
Cooling (SW2)
Clg SW2:
Heating
(SW1)
040---12
Clg Default:
Cooling (SW2)
Clg SW2:
Heating
(SW1)
060---12
Clg Default:
Cooling (SW2)
Clg SW2:
Heating
(SW1)
(SW1-5 and SW2---2 set to OFF, except as indicated. See notes 1 and 2)
Cooling Switch Settings
External Static Pressure (ESP)
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.030
OFF
OFF
OFF
1125
1080
1020
970
905
855
805
755
700
635
OFF
OFF
ON
615
555
510
475
440
395
355
270
230
note 8
OFF
ON
OFF
785
740
695
665
630
590
565
520
485
450
OFF
ON
ON
990
950
910
875
850
815
770
720
670
615
ON
OFF
OFF
1125
1080
1020
970
905
855
805
755
700
635
ON
OFF
ON
1125
1080
1020
970
905
855
805
755
700
635
ON
ON
OFF
1125
1080
1020
970
905
855
805
755
700
635
ON
ON
ON
1125
1080
1020
970
905
855
805
755
700
635
Maximum Clg Airflow 2
1125
1080
1020
970
905
855
805
755
700
635
High Heat Airflow 3
815
770
725
695
660
625
595
550
510
475
Low Heat Airflow 3
660
605
560
530
495
450
415
340
300
Note 7
1015
965
915
860
810
OFF
OFF
OFF
1250
1210
1165
1115
1065
OFF
OFF
ON
575
540
490
435
385
OFF
ON
OFF
770
725
685
640
600
560
515
480
OFF
ON
ON
945
910
875
835
800
770
735
695
665
635
ON
OFF
OFF
1140
1105
1075
1040
1005
970
930
885
835
790
ON
OFF
ON
1250
1210
1165
1115
1065
1015
965
915
860
810
ON
ON
OFF
1250
1210
1165
1115
1065
1015
965
915
860
810
ON
ON
ON
1250
1210
1165
1115
1065
1015
965
915
860
810
Maximum Clg Airflow 2
1250
1210
1165
1115
1065
1015
965
915
860
810
High Heat Airflow 3
860
825
785
745
705
670
630
595
565
525
Low Heat Airflow 3
650
595
545
500
460
415
365
320
275
note 7
1015
955
895
815
745
See note 4
See note 4
OFF
OFF
OFF
1250
1210
1165
1115
1065
OFF
OFF
ON
605
565
510
455
420
OFF
ON
OFF
785
750
705
675
630
585
OFF
ON
ON
955
920
895
860
825
785
755
720
685
650
ON
OFF
OFF
1135
1110
1080
1055
1020
990
935
880
825
745
ON
OFF
ON
1250
1210
1165
1115
1065
1015
955
895
815
745
ON
ON
OFF
1250
1210
1165
1115
1065
1015
955
895
815
745
ON
ON
ON
1250
1210
1165
1115
1065
1015
955
895
815
745
Maximum Clg Airflow 2
1250
1210
1165
1115
1065
1015
955
895
815
745
High Heat Airflow 3
1125
1100
1070
1045
1010
980
925
875
820
740
Low Heat Airflow 3
900
865
835
800
760
720
690
650
610
580
6
See note 4
See note 4
Unit Size
060---14
Clg Default:
Cooling (SW2)
Clg SW2:
Heating
(SW1)
080---16
Clg Default:
Cooling (SW2)
Clg SW2:
Heating
(SW1)
080-- 20
Clg Default:
Cooling (SW2)
Clg SW2:
Heating
(SW1)
Cooling Switch Settings
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
1150
1110
0.8
0.9
1.0
1075
1045
1005
OFF
OFF
OFF
1330
1295
1260
1220
1190
OFF
OFF
ON
725
660
600
520
435
See note 4
OFF
ON
OFF
780
725
660
615
540
See note 4
OFF
ON
ON
975
925
875
835
785
750
690
655
610
570
ON
OFF
OFF
1160
1120
1090
1045
1010
970
920
885
840
800
ON
OFF
ON
1330
1295
1260
1220
1190
1150
1110
1075
1045
1005
ON
ON
OFF
1705
1650
1595
1545
1475
1415
1340
1275
1200
1105
ON
ON
ON
1705
1650
1595
1545
1475
1415
1340
1275
1200
1105
Maximum Clg Airflow 2
1705
1650
1595
1545
1475
1415
1340
1275
1200
1105
High Heat Airflow 3
1145
1105
1075
1030
995
955
905
870
825
785
Low Heat Airflow 3
870
820
760
720
655
620
560
525
470
435
1610
1540
1475
1400
1315
1235
OFF
OFF
OFF
1805
1765
1720
1665
OFF
OFF
ON
775
635
455
230
OFF
ON
OFF
840
740
675
625
555
OFF
ON
ON
995
955
910
860
815
770
720
660
620
585
ON
OFF
OFF
1175
1140
1090
1060
1025
980
940
905
855
815
ON
OFF
ON
1325
1280
1245
1210
1180
1140
1105
1070
1025
990
ON
ON
OFF
1545
1515
1480
1445
1410
1380
1350
1315
1245
1175
ON
ON
ON
1805
1765
1720
1665
1610
1540
1475
1400
1315
1235
Maximum Clg Airflow 2
1805
1765
1720
1665
1610
1540
1475
1400
1315
1235
High Heat Airflow 3
1520
1490
1455
1420
1385
1355
1320
1285
1220
1155
Low Heat Airflow 3
1180
1145
1095
1065
1030
985
945
910
860
820
1665
1625
1560
1460
See note 8
See note 4
OFF
OFF
OFF
1905
1870
1825
1785
1750
1700
OFF
OFF
ON
950
770
620
515
440
365
OFF
ON
OFF
1015
935
880
825
765
690
625
580
OFF
ON
ON
1155
1105
1040
990
920
875
815
755
710
645
ON
OFF
OFF
1335
1290
1245
1190
1145
1085
1040
990
930
890
ON
OFF
ON
1520
1485
1435
1390
1340
1300
1255
1200
1160
1115
ON
ON
OFF
1905
1870
1825
1785
1750
1700
1665
1625
1560
1460
ON
ON
ON
2290
2230
2160
2085
2005
1915
1820
1730
1640
1525
Maximum Clg Airflow 2
2290
2230
2160
2085
2005
1915
1820
1730
1640
1525
High Heat Airflow 3
1575
1535
1485
1445
1400
1350
1310
1260
1215
1170
Low Heat Airflow 3
1230
1170
1125
1065
1015
955
900
855
795
755
NOTE: See notes at end of table.
7
See note 4
See note 4
59TP6A
AIR DELIVERY -- CFM (CONTINUED)
AIR DELIVERY -- CFM (CONTINUED)
Unit Size
100-- 20
Clg Default:
59TP6A
Cooling (SW2)
Clg SW2:
Heating
(SW1)
120-- 22
Clg Default:
Cooling (SW2)
Clg SW2:
Heating
(SW1)
Cooling Switch Settings
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
External Static Pressure (ESP)
0.4
0.5
0.6
0.7
1610
0.8
0.9
1.0
1560
1510
1460
OFF
OFF
OFF
1890
1845
1800
1755
1700
1655
OFF
OFF
ON
1015
825
630
485
405
325
OFF
ON
OFF
1080
895
815
740
690
615
555
475
OFF
ON
ON
1155
1080
1020
940
890
825
785
710
660
590
ON
OFF
OFF
1310
1260
1195
1140
1075
1025
970
925
875
810
ON
OFF
ON
1520
1475
1425
1365
1315
1255
1210
1155
1110
1055
ON
ON
OFF
1890
1845
1800
1755
1700
1655
1610
1560
1510
1460
ON
ON
ON
2290
2230
2160
2085
2005
1915
1820
1730
1640
1525
Maximum Clg Airflow 2
2290
2230
2160
2085
2005
1915
1820
1730
1640
1525
High Heat Airflow 3
1905
1865
1825
1775
1730
1685
1640
1590
1545
1490
Low Heat Airflow 3
1480
1435
1375
1330
1265
1215
1160
1115
1060
1005
1750
1690
1645
1565
1480
See note 4
See note 4
OFF
OFF
OFF
2010
1960
1910
1850
1800
OFF
OFF
ON
1015
805
645
550
480
See note 4
OFF
ON
OFF
1075
975
915
835
765
See note 4
OFF
ON
ON
1205
1135
1055
1000
935
See note 4
ON
OFF
OFF
1400
1330
1260
1190
1145
1080
1035
970
905
845
ON
OFF
ON
1615
1550
1500
1435
1370
1325
1265
1215
1160
1110
ON
ON
OFF
2010
1960
1910
1850
1800
1750
1690
1645
1565
1480
ON
ON
ON
note 8
2375
2300
2205
2115
2010
1890
1750
1645
1550
Maximum Clg Airflow 2
note 8
2375
2300
2205
2115
2010
1890
1750
1645
1550
High Heat Airflow 3
note 8
2375
2300
2205
2115
2010
1890
1750
1645
1550
Low Heat Airflow 3
1735
1675
1625
1560
1500
1455
1395
1345
1285
1225
1. Nominal 350 CFM/ton cooling airflow is delivered with SW1 ---5 and SW2 ---2 set to OFF.
Set both SW1 ---5 and SW2 ---2 to ON for +7% airflow (nominal 370 CFM/ton).
Set SW1 ---5 to ON and SW2 ---2 to OFF for +15% airflow (nominal 400 CFM/ton).
Set SW2 ---2 to ON and SW1 ---5 to OFF for ---7% airflow (nominal 325 CFM/ton).
The above adjustments in airflow are subject to motor horsepower range/capacity.
2. Maximum cooling airflow is achieved when switches SW2 ---6, SW2 ---7, SW2 ---8 and SW1 ---5 are set to ON, and SW2 ---2 is set to OFF.
3. All heating CFM’s are when low heat rise adjustment switch (SW1 ---3) and comfort/efficiency adjustment switch (SW1 ---4) are both set to OFF.
4. Ductwork must be sized for high ---heating CFM within the operational range of ESP. Operation within the blank areas of the chart is not recommended
because high ---heat operation will be above 1.0 ESP.
5. All airflows of 1880 CFM or less on 21” and 24.5” casing size furnaces are 5% less on side return only installations.
6. Return air above 1800 CFM on 24.5” casing requires two sides, one side and bottom, or bottom only to allow sufficient airflow to the furnace.
7. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
8. Airflow not stable at this ESP.
8
MAXIMUM EQUIVALENT VENT LENGTH - FT. (M)
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 1 – Maximum Equivalent Vent Length -- Ft. (M)
0 to 4500 Ft. (0 to 1370 M) Altitude
0 to 2000
(0 to 610)
2001 to 3000
(610 to 914)
3001 to 4000
(914 to 1219)
4001 to 4500
(1219 to 1370)
Unit Size
BTU/Hr
40,000 3
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
50
30
20
NA
NA
NA
45
27
17
NA
NA
NA
39
23
15
NA
NA
NA
36
21
14
NA
NA
NA
1-1/2
(15.2)
(9.1)
(6.1)
(13.7)
(8.2)
(5.2)
(11.9)
(7.0)
(4.6)
(11.0)
(6.4)
(4.3)
DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE)
Vent Pipe Diameter (in.) 1
2
2-1/2
3
210
(64.0)
250
(76.2)
NA 2
135
(41.1)
235
(71.6)
265
(80.8)
70
(21.3)
175
(53.3)
235
(71.6)
25
(7.6)
110
(33.5)
235
(71.6)
NA
15
(4.6)
100
(30.5)
NA
10
(3.0)
90
(27.4)
198
(60.4)
232
(70.7)
NA
127
(38.7)
222
(67.7)
250
(76.2)
64
(19.5)
165
(50.3)
222
(67.7)
22
(6.7)
104
(31.7)
223
(68.0)
NA
11
(3.4)
93
(28.3)
NA
NA
80
(24.4)
184
(56.1)
214
(65.2)
NA
119
(36.3)
210
(64.0)
235
(71.6)
59
(18.0)
155
(47.2)
210
(64.0)
19
(5.8)
98
(29.9)
211
(64.3)
NA
8
(2.4)
86
(26.2)
NA
NA
79
(24.1)
177
(53.9)
205
(62.5)
NA
115
(35.1)
204
(62.2)
228
(69.5)
56
(17.1)
150
(45.7)
202
(61.6)
17
(5.2)
94
(28.7)
205
(62.5)
NA
NA
83
(25.3)
NA
NA
69
(21.0)
4
NA
NA
265
265
250
210
NA
NA
249
250
237
185
NA
NA
232
236
224
158
NA
NA
224
229
217
146
(80.8)
(80.8)
(76.2)
(64.0)
(75.9)
(76.2)
(72.2)
(56.4)
(70.7)
(71.9)
(68.3)
(48.2)
(68.3)
(69.8)
(66.1)
(44.5)
NOTES: See notes at end of venting tables.
See Table 3 for altitudes over 4500 ft. (1370 M)
VENT TERMINAL CONFIGURATIONS
ELBOW CONFIGURATIONS
Concentric
Long
Medium
Mitered
Standard 2-in., 3-in., or
optional 4-in. termination.
A13110
Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
Pipe Diameter (in):
Mitered 90º Elbow
Medium Radius 90º Elbow
Long Radius 90º Elbow
Mitered 45º Elbow
Medium Radius 45º Elbow
Long Radius 45º Elbow
Tee
Concentric Vent Termination
Standard Vent Termination
1-1/2
8
5
3
4
2.5
1.5
16
2
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
NA
0
(0.0)
8
5
3
4
2.5
1.5
16
0
0
2-1/2
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
(0.0)
(0.0)
9
8
5
3
4
2.5
1.5
16
3
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
NA
0
(0.0)
8
5
3
4
2.5
1.5
16
0
0
4
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
(0.0)
(0.0)
8
5
3
4
2.5
1.5
16
(2.4)
(1.5)
(0.9)
(1.2)
(0.8)
(0.5)
(4.9)
NA
0
(0.0)
59TP6A
Altitude
FT (M)
Venting System Length Calculations
The Total Equivalent Vent Length (TEVL) for EACH combustion air or vent pipe equals the length of the venting system, plus the equivalent
length of elbows used in the venting system from Table 2.
Standard vent terminations or factory accessory concentric vent terminations count for zero deduction.
See vent system manufacturer’s data for equivalent lengths of flexible vent pipe or other termination systems. DO NOT ASSUME that one
foot of flexible vent pipe equals one foot of straight PVC/ABS DWV vent pipe.
Compare the Total Equivalent Vent Length to the Maximum Equivalent Vent Lengths in Tables 1 and 3.
Example 1
59TP6A
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M). Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a factory accessory concentric vent
kit.
Can this application use 2--in. (50 mm ND) PVC/ABS DWV vent piping?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
3
x
3 ft
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
2
x
1.5 ft
vent or inlet pipe)
Add equiv length of vent termination
100 ft
Use length of the longer of the vent
or air inlet piping system
=
9 ft.
From Table 2
=
3 ft.
From Table 2
0 ft.
Total Equivalent Vent Length (TEVL)
112 ft.
From Table 2
From Vent Manufacturer’s instructions;
zero for PVC/ABS DWV
Add all of the above lines
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
127 ft.
YES
For 2” pipe from Table 1
Therefore, 2” pipe may be used
Add correction for flexible vent pipe, if any
0 ft.
Example 2
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M) Venting system includes, FOR EACH PIPE, 100 feet (30 M) of vent pipe,
95 feet (28 M) of combustion air inlet pipe, (3) 90_ long radius elbows, and a polypropylene concentric vent kit. Also includes 20 feet (6 M)
of flexible polypropylene vent pipe, included within the 100 feet (30 M) of vent pipe.
Assume that one meter of flexible 60 mm or 80 mm polypropylene pipe equals 1.8 meters of PVC/ABS pipe. VERIFY FROM VENT
MANUFACTURER’S INSTRUCTIONS.
Can this application use 60 mm (O.D.) polypropylene vent piping? If not what size piping can be used?
Measure the required linear length of air inlet and vent pipe; insert the
longest of the two here:
Add equiv length of (3) 90º long-radius elbows
(use the highest number of elbows for either the
3
x
3 ft
vent or inlet pipe)
Add equiv length of (2) 45º long-radius elbows
(use the highest number of elbows for either the
0
x
vent or inlet pipe)
Add equiv length of vent termination
9M
x 3 ft/M
Add correction for flexible vent pipe, if any
1.8
x
20 ft
Total Equivalent Vent Length (TEVL)
100 ft
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
=
9 ft.
From Vent Manufacturer’s instructions
=
0 ft.
From Vent Manufacturer’s instructions
=
=
18 ft.
36 ft.
163 ft.
From Vent Manufacturer’s instructions
From Vent Manufacturer’s instructions
Add all of the above lines
127 ft.
For 2” pipe from Table 1
Therefore, 60mm pipe may NOT be used;
try 80 mm
NO
Maximum Equivalent Vent Length (MEVL)
Is TEVL less than MEVL?
250 ft.
YES
10
Use length of the longer of the vent
or air inlet piping system
For 3” pipe from Table 1
Therefore, 80 mm pipe may be used
MAXIMUM EQUIVALENT VENT LENGTH - FT. (M) (CONTINUED)
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 3 – Maximum Equivalent Vent Length -- Ft. (M)
4501 to 10,000 Ft. (1371 to 3048 M) Altitude
4501 to 5000
(1370 to 1524)
5001 to 6000
(1524 to 1829)
6001 to 7000
(1829 to 2134)
7001 to 8000
(2134 to 2438)
8001 to 9000
(2438 to 2743)
9001 to 10,000
(2743 to 3048)
DIRECT VENT (2-PIPE) AND SINGLE-PIPE
Vent Pipe Diameter (in.) 1
2
2-1/2
3
Unit Size
1-1/2
40,000
33
(10.1)
171
(52.1)
196
(59.7)
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
40,000
60,000
80,000
100,000
120,000
140,000 4
20
13
NA
NA
NA
27
16
11
NA
NA
NA
21
13
NA
NA
NA
NA
15
10
NA
NA
NA
NA
10
7
NA
NA
NA
NA
5
NA
NA
NA
NA
NA
(6.1)
(4.0)
111
54
16
NA
NA
158
103
49
12
NA
NA
145
96
44
10
NA
NA
133
89
40
NA
NA
NA
121
82
35
NA
NA
NA
110
76
31
NA
NA
NA
(33.8)
(16.5)
(4.9)
198
146
91
NA
NA
179
186
137
85
NA
NA
162
174
120
79
NA
NA
146
163
120
73
NA
NA
130
152
111
67
NA
NA
115
142
103
62
NA
NA
(60.4)
(44.5)
(27.7)
(8.2)
(4.9)
(3.4)
(6.4)
(4.0)
(4.6)
(3.0)
(3.0)
(2.1)
(1.5)
(48.2)
(31.4)
(14.9)
(3.7)
(44.2)
(29.3)
(13.4)
(3.0)
(40.5)
(27.1)
(12.2)
(36.9)
(25.0)
(10.7)
(33.5)
(23.2)
(9.4)
(54.6)
(56.7)
(41.8)
(25.9)
(49.4)
(53.0)
(36.6)
(24.1)
(44.5)
(49.7)
(36.6)
(22.3)
(39.6)
(46.3)
(33.8)
(20.4)
(35.1)
(43.3)
(31.4)
(18.9)
NA 2
221
195
200
80
60
NA
207
183
188
74
50
NA
194
171
178
68
41
NA
181
159
167
62
32
NA
168
148
157
56
23
NA
156
137
147
51
16
4
NA
(67.4)
(59.4)
(61.0)
(24.4)
(18.3)
(63.1)
(55.8)
(57.3)
(22.6)
(15.2)
(59.1)
(52.1)
(54.3)
(20.7)
(12.5)
(55.2)
(48.5)
(50.9)
(18.9)
(9.8)
(51.2)
(45.1)
(47.9)
(17.1)
(7.0)
(47.5)
(41.8)
(44.8)
(15.5)
(4.9)
NA
216
222
211
134
NA
NA
200
208
199
109
NA
NA
185
195
187
87
NA
NA
170
182
175
63
NA
NA
156
170
164
42
NA
NA
142
157
153
20
(65.8)
(67.7)
(64.3)
(40.8)
(61.0)
(63.4)
(60.7)
(33.2)
(56.4)
(59.4)
(57.0)
(26.5)
(51.8)
(55.5)
(53.3)
(19.2)
(47.5)
(51.8)
(50.0)
(12.8)
(43.3)
(47.9)
(46.6)
(6.1)
NOTES:
1. Use only the vent pipe sizes shown for each furnace. It is NOT necessary to choose the smallest diameter pipe possible for venting.
2. NA --- Not allowed. Pressure switch will not close, or flame disturbance may result.
3. Total equivalent vent lengths under 10’ for 40,000 BTUH furnaces from 0 to 2000 ft. (0 to 610 M) above sea level require use of an outlet choke plate .
Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout.
4. Not all furnace families include 140,000 BTUH input models.
5. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction.
6. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
7. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
8. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
9. The minimum pipe length is 5 ft. (2 M) linear feet (meters) for all applications.
10. Use 3 ---in. (76 mm) diameter vent termination kit for installations requiring 4 ---in. (102 mm) diameter pipe.
11
59TP6A
Altitude
FT (M) 5
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - FT. (M)
Two Stage
Furnace High
Heat Input
Winter Design
Temp ° F (° C)
20 (-10)
0 (-20)
40000*
-20 (-30)
-40 (-40)
59TP6A
20 (-10)
0 (-20)
60000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
80000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
100000
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
120000
-20 (-30)
-40 (-40)
Pipe
Length in
Ft. & M
No Insulation
3/8-in. (9.5 mm)
1/2-in. (12.7 mm)
Pipe Diameter-inches (mm)
Pipe Diameter-inches (mm)
Pipe Diameter-inches (mm)
1.5
2.0
2.5
3.0
4.0
1.5
2.0
2.5
3.0
4.0
1.5
2.0
2.5
3.0
4.0
(38)
(51)
(64)
(76)
(102)
(38)
(51)
(64)
(76)
(102)
(38)
(51)
(64)
(76)
(102)
Ft.
40.0
35.0
35.0
N/A
N/A
50.0
104.0
94.0
N/A
N/A
50.0
122.0 110.0
N/A
N/A
M
12.2
10.7
10.7
N/A
N/A
15.2
31.7
28.7
N/A
N/A
15.2
37.2
33.5
N/A
N/A
Ft.
19.0
14.0
12.0
N/A
N/A
50.0
61.0
54.0
N/A
N/A
50.0
74.0
65.0
N/A
N/A
M
5.8
4.3
3.7
N/A
N/A
15.2
18.6
16.5
N/A
N/A
15.2
22.6
19.8
N/A
N/A
Ft.
9.0
3.0
1.0
N/A
N/A
50.0
41.0
35.0
N/A
N/A
50.0
51.0
43.0
N/A
N/A
M
2.7
0.9
0.3
N/A
N/A
15.2
12.5
10.7
N/A
N/A
15.2
15.5
13.1
N/A
N/A
Ft.
3.0
0.0
0.0
N/A
N/A
39.0
29.0
23.0
N/A
N/A
48.0
37.0
30.0
N/A
N/A
M
0.9
0.0
0.0
N/A
N/A
11.9
8.8
7.0
N/A
N/A
14.6
11.3
9.1
N/A
N/A
Ft.
30.0
51.0
51.0
45.0
N/A
30.0
135.0 138.0 120.0
N/A
30.0
135.0 162.0 141.0
N/A
M
9.1
15.5
15.5
13.7
N/A
9.1
41.1
42.1
36.6
N/A
9.1
41.1
49.4
43.0
N/A
Ft.
30.0
24.0
23.0
16.0
N/A
30.0
93.0
82.0
69.0
N/A
30.0
111.0
98.0
83.0
N/A
M
9.1
7.3
7.0
4.9
N/A
9.1
28.3
25.0
21.0
N/A
9.1
33.8
29.9
25.3
N/A
Ft.
18.0
11.0
9.0
1.0
N/A
30.0
65.0
56.0
44.0
N/A
30.0
79.0
68.0
55.0
N/A
M
5.5
3.4
2.7
0.3
N/A
9.1
19.8
17.1
13.4
N/A
9.1
24.1
20.7
16.8
N/A
Ft.
10.0
3.0
0.0
0.0
N/A
30.0
48.0
40.0
29.0
N/A
30.0
59.0
50.0
38.0
N/A
M
3.0
0.9
0.0
0.0
N/A
9.1
14.6
12.2
8.8
N/A
9.1
18.0
15.2
11.6
N/A
Ft.
20.0
64.0
64.0
56.0
47.0
20.0
70.0
173.0 150.0 125.0
20.0
70.0
175.0 177.0 147.0
M
6.1
19.5
19.5
17.1
14.3
6.1
21.3
52.7
45.7
38.1
6.1
21.3
53.3
53.9
44.8
Ft.
20.0
32.0
30.0
22.0
11.0
20.0
70.0
104.0
87.0
67.0
20.0
70.0
124.0 104.0
82.0
M
6.1
9.8
9.1
6.7
3.4
6.1
21.3
31.7
26.5
20.4
6.1
21.3
37.8
31.7
25.0
Ft.
20.0
17.0
14.0
6.0
0.0
20.0
70.0
71.0
57.0
40.0
20.0
70.0
86.0
71.0
52.0
M
6.1
5.2
4.3
1.8
0.0
6.1
21.3
21.6
17.4
12.2
6.1
21.3
26.2
21.6
15.8
Ft.
15.0
7.0
5.0
0.0
0.0
20.0
61.0
52.0
40.0
24.0
20.0
70.0
64.0
50.0
33.0
M
4.6
2.1
1.5
0.0
0.0
6.1
18.6
15.8
12.2
7.3
6.1
21.3
19.5
15.2
10.1
Ft.
N/A
25.0
79.0
70.0
59.0
N/A
25.0
110.0 186.0 155.0
25.0
110.0 219.0 182.0
M
N/A
7.6
24.1
21.3
18.0
N/A
7.6
33.5
56.7
47.2
7.6
33.5
Ft.
N/A
25.0
40.0
31.0
19.0
N/A
25.0
110.0 109.0
86.0
25.0
110.0 131.0 104.0
66.8
55.5
M
N/A
7.6
12.2
9.4
5.8
N/A
7.6
33.5
33.2
26.2
7.6
33.5
39.9
31.7
Ft.
N/A
23.0
21.0
13.0
0.0
N/A
25.0
91.0
74.0
54.0
25.0
110.0
90.0
68.0
M
N/A
7.0
6.4
4.0
0.0
N/A
7.6
27.7
22.6
16.5
7.6
33.5
27.4
20.7
Ft.
N/A
13.0
10.0
1.0
0.0
N/A
25.0
68.0
53.0
35.0
25.0
83.0
66.0
46.0
M
N/A
4.0
3.0
0.3
0.0
N/A
7.6
20.7
16.2
10.7
7.6
25.3
20.1
14.0
Ft.
N/A
N/A
15.0
85.0
73.0
N/A
N/A
15.0
100.0 190.0
N/A
N/A
15.0
100.0 224.0
M
N/A
N/A
4.6
25.9
22.3
N/A
N/A
4.6
30.5
57.9
N/A
N/A
4.6
30.5
Ft.
N/A
N/A
15.0
41.0
29.0
N/A
N/A
15.0
100.0 109.0
N/A
N/A
15.0
100.0 131.0
68.3
M
N/A
N/A
4.6
12.5
8.8
N/A
N/A
4.6
30.5
33.2
N/A
N/A
4.6
30.5
39.9
Ft.
N/A
N/A
15.0
20.0
7.0
N/A
N/A
15.0
94.0
71.0
N/A
N/A
15.0
114.0
88.0
M
N/A
N/A
4.6
6.1
2.1
N/A
N/A
4.6
28.7
21.6
N/A
N/A
4.6
34.7
26.8
Ft.
N/A
N/A
15.0
7.0
0.0
N/A
N/A
15.0
69.0
48.0
N/A
N/A
15.0
85.0
62.0
M
N/A
N/A
4.6
2.1
0.0
N/A
N/A
4.6
21.0
14.6
N/A
N/A
4.6
25.9
18.9
* Not all families have these models.
* Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe
length calculated from Table 1 or 3.
† Insulation thickness based on R value of 3.5 per in.
12
RETURN AIR TEMPERATURE
This furnace is designed for continuous return--air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C)
db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F (27_C) db. Failure to follow these
return air limits may affect reliability of heat exchangers, motors and controls.
80
/ 27˚C
60
/ 16˚C
59TP6A
SUPPLY AIR
A10490
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITION
Rear
Front (Combustion air openings in furnace and in structure)
Required for service**
All Sides of Supply Plenum**
Sides
Vent
Top of Furnace
CLEARANCE
0 (0 mm)
1 in. (25 mm)
24 in. (610 mm)*
1 in. (25 mm)
0 (0 mm)
0 (0 mm)
1 in. (25 mm)
* Recommended
**Consult your local building codes
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
MITERED RADIUS
PVC 90° ELBOW
FIELD-SUPPLIED
2-IN. (51 mm) DIA.
PVC PIPE
12” (300 mm) MINIMUM
A12376
NOTE: See Installation Instructions for specific venting configurations.
13
DOWNFLOW SUBBASE
LOCATING
TAB
1 1/4-IN. TYP
PLENUM
OPENING
B
A
D
1
2
3
4
LOCATING
TAB
C
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
4
59TP6A
A97427
3
2
1
A88207
Assembled
Disassembled
DIMENSIONS (IN. / MM)
PLENUM OPENING*
FLOOR OPENING
HOLE NO. FOR
WIDTH
ADJUSTMENT
FURNACE
CASING WIDTH
FURNACE IN DOWNFLOW
APPLICATION
B
C
D
14--- 3/16 (360)
Furnace with or without Cased Coil
Assembly or Coil Box
11--- 3/16
(322)
19 (483)
13--- 7/16
(341)
20--- 5/8
(600)
4
17--- 1/2 (445)
Furnace with or without Cased Coil
Assembly or Coil Box
15--- 1/8
(384)
19 (483)
16--- 3/4
(426)
20--- 5/8
(600)
3
21 (533)
Furnace with or without Cased Coil
Assembly or Coil Box
18--- 5/8
(396)
19 (483)
20--- 1/4
(514)
20--- 5/8
(600)
2
24--- 1/2 (622)
Furnace with or without Cased Coil
Assembly or Coil Box
22--- 1/8
(562)
19 (483)
23--- 3/4
(603)
20--- 5/8
(600)
1
A
*The plenum should be constructed 1/4 ---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
Concentric Vent Kit
Downflow Subbase
A93086
A88202
A concentric vent kit allows vent and combustion--air pipes to
terminate through a single exit in a roof or side wall. One pipe
runs inside the other allowing venting through the inner pipe and
combustion air to be drawn in through the outer pipe.
One base fits all furnace sizes. The base is designed to be installed
between the furnace and a combustible floor when no coil box is
used or when a coil box other than a Carrier cased coil is used. It is
CSA design certified for use with Carrier branded furnaces when
installed in downflow applications.
14
OPTIONAL MEDIA FILTER CABINET
25-5/8"
(651mm)
24-1/4”
(616mm)
Opening with Flanges Bent
23-1/8”
(588mm)
Opening
23-5/8"
(600mm)
23-3/8”
(594mm)
B Opening
59TP6A
A
Duct Side
Furnace Side
23-3/4”
(603mm)
Centerline Screw Slots
5 3 4"
(146mm)
Media Filter
A
B
Cabinet
16" (406mm) 17" (432mm) 16" (406mm)
20" (508mm) 21" (533mm) 20" (508mm)
24" (610mm) 25" (635mm) 24" (610mm)
NOTE: Media cabinet is matched to the bottom opening on furnace. May also be used for side return.
A12428
TYPICAL WIRING SCHEMATIC
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
NOTE 2
W
FIVE WIRE
THREE-WIRE
HEATING-ONLY
C
R
G
Y
THERMOSTAT
TERMINALS
FIELD-SUPPLIED
DISCONNECT
208/230- OR
460-V
THREE
PHASE
BLOWER DOOR SWITCH
BLK
W
BLK
WHT
WHT
GND
115-V FIELDSUPPLIED
DISCONNECT
GND
AUXILIARY
J-BOX
C
O
N
T
R
O
L
R
208/230-V
SINGLE
PHASE
G
COM
GND
NOTE 1
CONDENSING
UNIT
Y
24-V
TERMINAL
BLOCK
FURNACE
TWO
WIRE
NOTES: 1. Connect Y-terminal in furnace as shown for proper blower operation.
2. Some thermostats require a "C" terminal connection as shown.
3. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
A11387
15
59TP6A
FURNACE SIZE
040--- 10
040--- 12
060--- 12
060--- 14
080--- 16
080--- 20
100--- 20
120--- 22
25 1/8
[638.7]
16
A
CABINET WIDTH
B
OUTLET WIDTH
C
BOTTOM INLET WIDTH
D
AIR INTAKE
14--- 3/16 (361)
12--- 1/2 (319)
12--- 9/16 (322)
7--- 1/8 (181)
17--- 1/2 (445)
15--- 7/8 (403)
16 (406)
8--- 3/4 (222)
21 (533)
19--- 3/8 (492)
19--- 1/2 (495)
10--- 1/2 (267)
24--- 1/2 (622)
22--- 7/8 (581)
23 (584)
12--- 1/4 (311)
21
[534.0]
26 5/16
[668.8]
22
[558.3] (BOTH SIDES)
1 (BOTH SIDES)
[25.4]
7/8
[22.2]
THERMOSTAT ENTRY
SIDE INLET
2 1/2
[63.5]
7/8
[22.2]
7/8
[22.2]
7/8
[22.2]
4
[101.6]
CONDENSATE DRAIN TRAP
LOCATION
AIR FLOW
19 1/8
[485.8]
20 5/8
[522.7]
23 5/16
[592.9]
26 3/8
[670.0]
26 11/16
[678.1]
TOP VIEW
6 11/16
[170.1]
6 15/16
[176.1]
D
SEE NOTE #3
14 13/16
[376.3]
16 9/16
[420.9]
17 5/16
[439.2]
7/8
[22.2] POWER CONN
3
[76.2]
VENT
1 3/4
[44.5]
GAS CONN
3
[76.2]
AIR INTAKE
3
[76.2]
AIR INTAKE
3
[76.2]
VENT
2 3/10
[58.4]
23 7/16
[595.6] 25 3/16
[639.1]
22 15/16
[581.9]
20 1/4
[513.9]
28 5/8
[726.4]
28 3/16
[715.9]
11/16
[17.5]
32 5/8
[829.5]
5/8
[15.8]
NOTE: ALL DIMENSIONS IN INCH [MM]
C
BOTTOM RETURN
WIDTH
AIR FLOW
B
OUTLET WIDTH
A
2 1/2
[63.5]
1 5/16
[33.3]
6 1/16
[154.0]
16 9/16
[420.9]
17 7/16
[442.3]
20 1/4
[513.9] 18 1/16
[458.6]
24
[609.7]
28 3/8
[720.4]
28 5/8
[726.9]
29 13/16
[757]
11/16
[17.5]
35
[889.0]
3
[76.2 ]
3
[76.2]
AIR INTAKE
2
NEXT SHEET
SD5024-4
PART NUMBER
7/8
[22.2]
4
[101.6]
SIDE INLET
7/8
[22.2] POWER CONN
7/8
[22.2]
1 3/4
[44.5]
GAS CONN
7/8
[22.2]
AIR FLOW
20 5/8
[522.7]
21 1/16
[535.8]
21 15/16
[557.4]
26 3/8
[669.9]
26 11/16
[678.1]
28 3/4
[730.5]
29 1/2
[749.3]
REV
E
SHT
1
BOTTOM INLET
21 5/8
[549.5]
23 3/8
[592.0]
26 5/16
[668.8]
7/8
[22.2]
THERMOSTAT ENTRY
NOTES:
1. Doors may vary by model.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle.
b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle.
c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle.
d. Return air above 1800 CFM at 0.5 in. w.c. ESP on 24.5" casing, requires one of the following
configurations: 2 sides, 1 side and a bottom or bottom only. See Air Delivery table in this
document for specific use to allow for sufficient airflow to the furnace.
3. Vent and Combustion air pipes through blower compartment must
use accessory “Vent Kit - Through the Cabinet”. See accessory list for
current part number.
59TP6A
DIMENSIONAL DRAWING
SHIP WT.
LB (KG)
A12267
121.0 (55.0)
130.5 (59.2)
131.5 (59.6)
142.0 (64.4)
152.0 (68.9)
156.0 (70.8)
166.0 (75.3)
190.0 (86.2)
GUIDE SPECIFICATIONS
System Description
Furnish a ______________________ 4--way multipoise gas--fired
condensing furnace for use with natural gas or propane (factory-authorized conversion kit required for propane); furnish external
media cabinet for use with accessory media filter or standard filter.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit
will carry the CSA Blue StarR and Blue FlameR labels. Unit
efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and ECM Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be
permanently lubricated with sealed ball bearings, of _______hp,
and have infinitely variable speed from 600--1200 RPM operating
only when motor inputs are provided. Blower motor shall be direct
drive and soft mounted to the blower housing to reduce vibration
transmission.
Filters
Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media
Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted steel.
Draft Inducer Motor
Draft inducer motor shall be two--speed PSC design.
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass corrosion--resistant
aluminized steel of fold--and--crimp sectional design and applied
operating under negative pressure.
Secondary Heat Exchangers
Secondary heat exchangers shall be of a stainless steel
flow--through of fin--and--tube design and applied operating under
negative pressure.
Controls
Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting
codes displayed via diagnostic flashing LED light on the control, a
self--test feature that checks all major functions of the furnace, and
a replaceable automotive--type circuit protection fuse. Multiple
operational settings available, including separate blower speeds for
low heat, high heat, low cooling, high cooling and continuous fan.
Continuous fan speed may be adjusted from the thermostat.
Cooling airflow will be selectable between 325 to 400 CFM per
ton of air conditioning. Features will also include temporary
reduced airflow in the cooling mode for improved
dehumidification when a TP--PRH is selected as the thermostat.
Operating Characteristics
Heating capacity shall be _________________ Btuh input;
______________ Btuh output capacity.
Fuel Gas Efficiency shall be________ AFUE.
Air delivery shall be ________________ cfm minimum at 0.50 in.
W.C. external static pressure.
Dimensions shall be: depth_________in. (mm); width
__________in. (mm); height___________in. (mm) (casing only).
Height shall be _________in. (mm) with A/C coil and
_________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal).
Minimum wire size shall be ________AWG; maximum fuse size
of HACR--type designated circuit breaker shall be _________
amps.
Special Features
Refer to section of the product data identifying accessories and
descriptions for specific features and available enhancements.
17
59TP6A
General
59TP6A
Copyright 2014 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Edition Date:08/14
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
18
Catalog No: 59TP6A ---02PD
Replaces: 59TP6A--- 01PD
©
Air Conditioning Contractors of America
Manual S (Residential Equipment Selection)
Project Information
Cooling Design Information
Name: Longwell Residence - Main Home
Outdoor Design Temp:
City: Hayden Lake
State: ID
Altitude: 2125
Altitude Adjustment:
0.97
86
°F db
Summer
Outdoor Design Temp:
-1
°F db
Winter
Indoor Design Temp:
75
°F db
50
%RH
°F wb
63
Airflow Calculations
Manual J Load Calculations
Total Load
Sensible
Latent
SHR
46598
45388
1210
0.974
Heat Loss
67380
Design TD for Airflow
17
Design Sensible CFM
2427
OEM Information
Manufacturer:
Carrier
Furnace Model #: 59MN7A080V21--20
Coil or Fan-Coil Model #: CNPHP4821ACA
Condenser Model #: 24ACC648A0030
AFUE:
96.0
SEER:
16.0
HSPF:
(A) Manufacturer's Cooling Performance Data
Entering Coil Temperature = 75 (F db)
Lower
CFM
Rated CFM @ Rated RA Temperature
Rated CFM @ Design RA Temperature
1200
Rated CFM @ Rated RA Temperature
Return Air
(F wb)
(F db)
95
Latent BTUH
Outdoor Temperature =
Total BTUH
Sensible BTUH
SHR
67
35,700
25,100
10,600
0.703
63
28,180
26,060
2,120
0.925
62
26,300
26,300
1
(B) Manufacturer's Cooling Performance Data
Entering Coil Temperature = 75 (F db)
Higher
CFM
Rated CFM @ Rated RA Temperature
Rated CFM @ Design RA Temperature
1600
Rated CFM @ Rated RA Temperature
Return Air
(F wb)
(F db)
95
Latent BTUH
Outdoor Temperature =
Sensible BTUH
Total BTUH
SHR
67
43,300
31,400
11,900
0.725
63
35,300
32,920
2,380
0.933
62
33,300
33,300
1
Outdoor Temperature = 95 (F db)
Sensible BTUH
Total BTUH
Latent BTUH
SHR
Manufacturer's Cooling Performance Data (Interpolated)
Design
CFM
Return Air
(F wb)
2,918
47,106
Excess Latent Capacity Calculation
Capacity @ Design CFM / RA (F wb)
854
+
2427
63
Equipment Capacity as a % of Design
-
854
50,024
47,960
2,064
107.35%
105.67%
170.56%
Manufacturer's Heat Pump Data
Capacity
@ 47 °F db
Capacity
@ 17 °F db
Balance
Point
Supplemental
Heat Required
65.0
19.74
Manufacturer's Furnace Data
Input
Capacity
80,000
Output
Capacity
78,000
AFUE
97.0
Desired
Temp. Rise
45
0.942
Calculated
Airflow
1,605
0.959
Air Conditioning Contractors of America, Manual D, Third Edirtion
Effective Length Worksheet
Element
Supply Run ID Number
#1
Straight Run
Length
25
Trunk Length
Trunk Length
Trunk Length
Runout Length
Fittings
Group 1 ◄
Group 2 ◄
Group 3 ◄
Group 4 ◄
Group 8 ◄
Group 9 ◄
Group 11 ◄
Group 12 ◄
Other
Other
Other
Other
Other
Total Length
Design TEL
Element
Group
Letters
C
C
10
Effective
Length
35
80
A
80
1
25
Length
Effective
Length
Group
Letters
0
Effective
Length
Length
Group
Letters
Effective
Length
0
0
Length
Length
255
Return Run ID Number
#1
Length
10
Trunk Length
Trunk Length
Trunk Length
Runout Length
Group 5 ◄
Group 6 ◄
Group 7 ◄
Group 8 ◄
Group 10 ◄
Group 11 ◄
Group 12 ◄
Other
Other
Other
Other
Total Length
Design TEL
Group
Letters
255
Straight Run
Fittings
Length
Group
Letters
A
C
Effective
Length
50
35
95
Length
Group
Letters
Effective
Length
0
Group
Letters
Effective
Length
0
95
Group
Letters
Effective
Length
0
Air Conditioning Contractors of America, Manual D, Third Edition
Friction Rate Worksheet
Step 1) Manufacturer's Blower Data
External static pressure (ESP)
CFM from manufacturers tables
Fan Speed
Step 2) Component Pressure Losses (CPL)
Direct expansion refrigerant coil
Electric resistance heating coil
Hot water coil
heat exchanger
Low efficiency filter
High or mid-efficiency filter
Electronic filter
Humidfier
Supply outlet
Return grille
Balancing damper ◄
UV lights or other device
Total component losses (CPL)
Step 3) Available Static Pressure (ASP)
Step 4) Total Effective Length (TEL)
Step 5) Friction Rate Design Value (FR)
1
Heating
1600
Med-Hi
IWC
Cooling
1600
Med-Hi
0.18
0.45
0.03
0.03
0.03
0.72
0.28
350
0.08
IWC
IWC
Feet
IWC/100
ID
RT-1
RT-2
RT-3
RT-4
ID
RR-1
RR-2
RR-3
RR-4
RR-5
RR-6
RR-7
RR-8
RR-9
RR-10
ST-1
ST-2
ST-3
ST-4
ST-5
ST-6
ST-7
ST-8
ID
ID
SR-1
SR-2
SR-3
SR-4
SR-5
SR-6
SR-7
SR-8
SR-9
SR-10
SR-11
SR-12
SR-13
SR-14
SR-15
SR-16
SR-17
SR-18
SR-19
SR-20
1
2
3
4
5
6
Room ID
master bedroom
master closet
bedroom 1
bedroom 2
bath 1
bedroom 3
bath 2
living room
kitchen
dining/entry
laundry/bath 3
pantry/stairs
63905
8
Return-side Runouts
9 10 11 12 13 14 15 16 17 18 19 20
Associated Supply Runs
Return-side Trunks
Associated Supply Runs
7
Associated Supply Runs
18
12
16
906
661
801
20
12
18
Dsn Cfm Round Size Velocity Final Size
Dsn Cfm Round Size Velocity Final Size
1600
18
906
20
1600
519
1118
Dsn Cfm Round Size Velocity Final Size
1865
43141
H-Btuh
5121
8084
6282
6368
284
6576
2924
9948
3117
7686
6113
1402
1600
1600
Supply-side Trunks
Supply-side Runouts
C-Btuh
Htg Cfm Clg Cfm Dsn Cfm Round Size Velocity Final Size
5555
128
206
8
591
8
206
4392
202
202
8
580
8
163
3423
157
157
8
451
8
127
2906
159
108
159
8
457
8
284
7
11
4
121
4
11
4706
165
175
175
8
500
8
629
23
73
6
373
6
73
10918
249
405
405
12
516
12
2039
78
78
6
398
6
76
5244
192
194
194
8
557
8
1680
153
62
153
8
439
8
1365
35
51
51
5
371
5
Duct Sizing Worksheet 1
20
9
16
Width
Equivilent Rect. Duct
Height
Width
Equivilent Rect. Duct
Height
Width
16
20
16
12
16
Height
Equivilent Rect. Duct
Equivilent Rect. Duct
Height
Width
10
5
10
5
10
5
10
5
10
1
10
5
10
3
10
11
10
3
10
5
10
5
10
2
Air Conditioning Contractors of America, Manual D, Third Edition
Equivilent
Flex
Equivilent
Flex
20
20
14
18
Flex
Equivilent
Equivilent
Flex
9
9
8
8
4
9
6
12
6
9
8
5
Residential Submittal Sheet
1050 Series
Return Air Grille
Model:
1050
Description:
Return Air Grille 1/2” Spacing
Standard Features:




1/2” spacing dual angular louvers
Stamped from cold roll steel
Install with louvers in up or down position for best duct concealment
Countersunk mounting holes for flush appearance with color matching Phillips posidrive screws
 Soft White
Options:
☐ Aluminum construction (A-1050)
☐ Heavy Duty construction (1075)
Tamper Proof Screws
☐ “F” Torx Center Pin
Finishes:
Standard Colors
Designer Colors
Plated Metal
☐ Soft White
☐ Driftwood Tan
☐ Almond
☐ Black Velvet
☐ Bronze
☐ Camaro Silver
☐ Coffee Tan
☐ Navajo White
☐ Vanilla
☐ Antique Brass
☐ Black Nickel
☐ Oil Rub Bronze
☐ Pewter
☐ Polished Brass
☐ Polished Chrome
☐ Satin Nickel
Additional Information:
Project / Location:
Submittal Notes
Engineer:
Architect:
Contractor:
Last Revised: 10/16/2014
Performance Data
1050 and 1075 Series
Size
8x4
8x6
8x8
10x4
10x6
10x8
10x10
12x4
12x6
12x8
12x10
12x12
14x4
14x6
14x8
14x10
14x12
14x14
16x4
16x6
16x8
16x10
16x12
16x14
16x16
18x4
18x6
18x8
18x10
18x12
18x14
18x16
18x18
20x4
20x6
20x8
20x10
20x12
20x14
20x16
20x18
20x20
24x4
24x6
24x8
24x10
Eff. Area
(ft2)
0.147
0.220
0.294
0.197
0.295
0.393
0.492
0.239
0.359
0.478
0.598
0.717
0.278
0.417
0.556
0.695
0.834
0.973
0.284
0.427
0.569
0.711
0.853
0.995
1.138
0.353
0.530
0.707
0.884
1.060
1.237
1.414
1.590
0.353
0.530
0.706
0.883
1.060
1.236
1.413
1.589
1.766
0.422
0.633
0.844
1.055
Velocity
Duct Pt
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
300
0.007
44
66
88
59
89
118
148
72
108
143
179
215
83
125
167
209
250
292
85
128
171
213
256
299
341
106
159
212
265
318
371
424
477
106
159
212
265
318
371
424
477
530
127
190
253
317
400
0.010
59
88
118
79
118
157
197
96
143
191
239
287
111
167
222
278
334
389
114
171
228
284
341
398
455
141
212
283
353
424
495
565
636
141
212
283
353
424
494
565
636
706
169
253
338
422
600
0.023
88
132
176
118
177
236
295
143
215
287
359
430
167
250
334
417
500
584
171
256
341
427
512
597
683
212
318
424
530
636
742
848
954
212
318
424
530
636
742
848
954
1060
253
380
506
633
800
0.040
118
176
235
157
236
315
393
191
287
382
478
574
222
334
445
556
667
779
228
341
455
569
683
796
910
283
424
565
707
848
990
1131
1272
283
424
565
706
848
989
1130
1272
1413
338
506
675
844
1000
0.064
147
220
294
197
295
393
492
239
359
478
598
717
278
417
556
695
834
973
284
427
569
711
853
995
1138
353
530
707
884
1060
1237
1414
1590
353
530
706
883
1060
1236
1413
1589
1766
422
633
844
1055
1200
0.090
176
264
353
236
354
472
590
287
430
574
717
860
334
500
667
834
1001
1168
341
512
683
853
1024
1194
1365
424
636
848
1060
1272
1484
1696
1908
424
636
848
1060
1272
1483
1695
1907
2119
506
760
1013
1266
1400
0.123
206
309
411
275
413
551
688
335
502
669
837
1004
389
584
779
973
1168
1362
398
597
796
995
1194
1393
1593
495
742
990
1237
1484
1732
1979
2226
494
742
989
1236
1483
1731
1978
2225
2472
591
886
1182
1477
1600
0.160
235
353
470
315
472
629
787
382
574
765
956
1147
445
667
890
1112
1335
1557
455
683
910
1138
1365
1593
1820
565
848
1131
1414
1696
1979
2262
2544
565
848
1130
1413
1695
1978
2261
2543
2826
675
1013
1351
1688
Performance Data
1050 and 1075 Series
Size
24x12
24x14
24x16
24x18
24x20
24x24
25x12
25x14
25x16
25x18
25x20
30x6
30x8
30x10
30x12
30x14
30x16
30x18
30x20
30x24
30x30
36x6
36x8
36x10
36x12
36x14
36x16
36x18
36x20
36x24
36x30
36x36
Eff. Area
(ft2)
1.266
1.477
1.688
1.899
2.110
2.532
1.265
1.476
1.687
1.898
2.108
0.874
1.165
1.456
1.747
2.038
2.329
2.621
2.912
3.494
4.368
1.045
1.394
1.742
2.091
2.439
2.787
3.136
3.484
4.181
5.226
6.272
Velocity
Duct Pt
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
300
0.007
380
443
506
570
633
760
380
443
506
569
633
262
349
437
524
611
699
786
874
1048
1310
314
418
523
627
732
836
941
1045
1254
1568
1881
400
0.010
506
591
675
760
844
1013
506
590
675
759
843
349
466
582
699
815
932
1048
1165
1398
1747
418
557
697
836
976
1115
1254
1394
1672
2091
2509
600
0.023
760
886
1013
1140
1266
1519
759
886
1012
1139
1265
524
699
874
1048
1223
1398
1572
1747
2096
2621
627
836
1045
1254
1463
1672
1881
2091
2509
3136
3763
800
0.040
1013
1182
1351
1519
1688
2026
1012
1181
1349
1518
1687
699
932
1165
1398
1631
1864
2096
2329
2795
3494
836
1115
1394
1672
1951
2230
2509
2787
3345
4181
5017
Performance Notes:
1)
Effective core areas listed in chart are
defined as the measurement of space
between the blades actually being
utilized by the air
2)
Data obtained from tests conducted in
accordance with ANSI/ASHRAE standard
70-2006
1000
0.064
1266
1477
1688
1899
2110
2532
1265
1476
1687
1898
2108
874
1165
1456
1747
2038
2329
2621
2912
3494
4368
1045
1394
1742
2091
2439
2787
3136
3484
4181
5226
6272
1200
0.090
1519
1773
2026
2279
2532
3039
1518
1771
2024
2277
2530
1048
1398
1747
2096
2446
2795
3145
3494
4193
5241
1254
1672
2091
2509
2927
3345
3763
4181
5017
6272
7526
1400
0.123
1773
2068
2363
2659
2954
3545
1771
2066
2361
2657
2952
1223
1631
2038
2446
2853
3261
3669
4076
4892
6115
1463
1951
2439
2927
3415
3902
4390
4878
5853
7317
8780
1600
0.160
2026
2363
2701
3039
3376
4052
2024
2361
2699
3036
3373
1398
1864
2329
2795
3261
3727
4193
4659
5591
6988
1672
2230
2787
3345
3902
4460
5017
5575
6690
8362
10035
Residential Submittal Sheet
350 Series
Stamped Deluxe Floor Register
Model:
350
Description:
Stamped Deluxe Floor Register
Standard Features:
Heavy gauge cold-rolled steel formed face
Louvers designed with rolled rib for maximum strength and rigidity
Unique fan-shaped air pattern lends to both heating and air conditioning applications
Opposed Blade Damper standard on 4" widths
Multi-Shutter Damper standard on 6" widths and larger
All component parts, rivets, linkage, and handle, enclosed in valve to assure troublefree operation
 Driftwood Tan or Soft White






Finishes:
Standard Colors
Designer Colors
Plated Metal
☐ Soft White
☐ Driftwood Tan
☐ Almond
☐ Black Velvet
☐ Bronze
☐ Camaro Silver
☐ Coffee Tan
☐ Navajo White
☐ Vanilla
☐ Antique Brass
☐ Black Nickel
☐ Oil Rub Bronze
☐ Pewter
☐ Polished Brass
☐ Polished Chrome
☐ Satin Nickel
Additional Information:
Project / Location:
Submittal Notes
Engineer:
Architect:
Contractor:
Last Revised: 11/10/2016
Performance Data
350 Series
Size
Eff. Area
(ft2)
2x10
0.099
2x12
2x14
4x6
4x8
4x10
4x12
4x14
6x6
6x8
6x10
6x12
6x14
8x8
8x10
8x12
0.120
0.141
0.107
0.147
0.186
0.226
0.265
0.170
0.233
0.296
0.359
0.421
0.290
0.368
0.446
Velocity
Duct Pt.
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
CFM
NC
Spread
Throw
1
2
2
1
2
3
4
4
2
2
4
4
5
4
5
5
300
400
500
600
700
800
900
1000
0.007
30
<20
2.5
1.5
36
<20
3
2
42
<20
3
2
32
<20
3
2
44
<20
3
3
56
<20
3
3.5
68
<20
3.5
4.5
80
<20
4
4.5
51
<20
4
3
70
<20
4.5
3.5
89
<20
5
4.5
108
<20
6
5
126
<20
6
5.5
87
<20
6
5
110
<20
7
5.5
134
<20
8
6
0.011
40
20
3
2
48
20
3.5
2.5
57
20
4
2.5
43
20
3.5
2.5
59
20
4
4
75
20
4
5
90
20
5
5.5
106
20
5
6
68
20
5
4.5
93
20
6
5.5
118
20
7
6.5
143
20
8
6.5
168
20
8
7
116
20
8
6.5
147
20
9
7
178
20
10
7.5
0.017
50
25
4
3
60
25
4.5
3
71
25
5
3
54
25
4.5
3
73
25
5
5
93
25
5
6.5
113
25
6
7
133
25
6
7
85
25
5
5.5
117
25
7
6.5
148
25
9
7.5
179
25
9
8
211
25
11
9
145
25
9
8
184
25
10
8.5
223
25
11
9.5
0.024
60
25
5
3
72
25
5.5
3.5
85
25
5.5
4
64
25
5.5
3.5
88
25
6
5.5
112
25
6
7
136
25
7
7.5
159
25
7
8.5
102
25
8
6.5
140
30
9
7.5
178
30
10.5
8.5
215
30
11
9.5
253
30
13
10
174
30
11
9
221
30
12
9.5
267
30
14
10.5
0.034
70
30
5.5
3.5
84
30
6
4
99
30
6.5
4.5
75
30
6
4
103
30
7
6.5
131
30
7
8.5
158
30
8
9.5
186
30
9
10
119
30
8
7
163
35
10
8.5
207
35
12
10
251
35
13
11
295
35
15
12.5
203
35
13
10.5
257
35
15
12
312
35
17
13
0.044
79
30
6
4
8
96
30
7
4.5
9
113
30
7.5
5
10
86
30
7
4.5
9
118
35
8
7.5
11
149
35
8
9.5
13
181
35
9
11 15.5
212
35
10
11.5 16
136
35
10
8
11
187
35
12
10
14
237
40
14
11.5 16
287
40
15
13
17
337
40
17
14.5 20
232
40
15
12.5 16.5
294
40
17
14
19
356
40
19
15.5 21
0.055
89
35
7
4.5
9
108
35
8
5
10.5
127
35
8
6
12
97
35
8
5
10.5
132
35
9
7.5
12
168
35
10
10
15
203
35
10
11.5 17.5
239
35
11
12.5 18
153
35
11
8
13
210
40
13
11.5 17
266
40
15
12
18
323
40
17
13
20
379
40
18
15
22
261
40
16
12.5 19
331
40
18
14.5 21
401
40
20
16
23
0.068
99
35
8
5
10
120
35
9
5.5 11.5
141
35
9
6.5
13
107
35
9
5.5 11.5
147
40
10
8.5
16
186
40
11
11
18
226
40
12
12.5 19
265
40
12
13.5 20
170
40
13
10.5 16
233
40
15
12
18
296
40
17
13.5 20
359
45
19
15
22
421
45
21
17
25
290
40
18
14.5 21
368
45
20
16
24
446
45
23
18
26
3
1
3.5
2
4
2
3.5
2
4
3
5
4
5.5
5
6.5
5
4
4
4.5
5
6
5
6
5
7
6
6
5
7
6
7
6
4
2
4.5
2
5
2
4.5
2
6
4
6
5
7
6
8
6
6
5
6.5
6
8
7
7.5
7
9
8
7.5
7
9
8
9.5
8
5
2
5.5
3
7
3
5.5
3
8
4
9
6
9.5
7
9
7
7
6
7.5
6
10
7
10
8
11
9
10
8
11
8
12
9
6
2
7
3
8
4
7
3
9
5
10
7
10.5
8
12
8
10
6
10.5
7
12
8
12.5
9
14
10
12.5
9
14
10
15
11
7
3
7.5
3
9
4
7.5
4
10
6
12
8
12.5
9
13.5
9
10
7
11.5
8
14
9
15
11
17
12
14.5
10
16
12
18
13
4
4
5
4
6
8
10
10
7
9
10
11
13
10
12
13
4
5
6
5
7
9
11
11
9
10
11
13
14
12
13
15
Performance Data
350 Series
Size
Eff. Area
(ft2)
8x14
0.523
Velocity
Duct Pt.
CFM
NC
Spread
Throw
5
300
400
500
600
700
800
900
1000
0.007
157
<20
9
6.5
0.011
209
20
12
8
0.017
262
25
13
10
0.024
314
30
16
11
0.034
366
35
19
14
0.044
419
40
22
16.5
0.055
471
40
23
17
0.068
523
45
26
19
8
7
10
9
13
9
16
12
19
14
22
14
25
16
Performance Notes:
1)
2)
Throw values are measured in feet for terminal velocities of
150/100/50 FPM
Throw data is based on supply air and room air both at
isothermal conditions
3)
Effective core areas listed in chart are defined as the
measurement of space between the blades actually being
utilized by the air
4)
Data obtained from tests conducted in accordance with
ANSI/ASHRAE standard 70-2006
28
FORM J1AE ● ABRIDGED VERSION of MANUAL J, 8TH EDITION
Project
Design State & City
Longwell Residence Upper Level
Idaho
Coeur D’Alene AP
Indoor Design Heating db
70
@ Outdoor (Winter) 99% db
-1
HTD
Indoor Design Cooling db
75
@ Outdoor (Summer) 1% db
86
CTD
Indoor Design Cooling RH
50%
Grains Difference
-23
Daily Range
Latitude
6A Windows
& Glass
Doors
47
Elevation
3002
71
11
Medium
0.890
ACF
Block Load
Glass
.
Heating
Cooling
Net
Heating
Cooling
Direction
Construction Detail
HTM
HTM
Area
BTUH
BTUH
48
1159
960
31
736
1098
N
1,3A-1,Dbl Pane, Clear,CTD=10
24.14
20.00
E/W
1,3A-1,Dbl Pane, Clear,CTD=10
24.14
70.00
S
1,3A-1,Dbl Pane, Clear,CTD=10
24.14
36.00
11D,wood,solid core
27.69
8.19
12F-0b w/m, frame, R0 board, R21 cavity, siding
4.62
0.67
852
3932
570
12B-0, Frame, R0 board, R11 cavity
6.89
1.26
189
1302
238
18A-38,below roof joists,R38,Shingles,Dark
2.06
2.06
908
1870
1870
22B-10ph; Slab floor; R10; heavy moist
34.15
19A-11p; Partition floor; R11 floor; Any Cover
4.75
1.90
775
3677
1471
6975
3313
275
6B Skylights
7
8
Wood &
a
Metal
b
Doors
c
a
Above Grade Walls
b
c
d
e
Partition Walls
f
g
9
Below Grade Walls
a
b
10 Ceilings
a
b
c
Partition Ceilings
d
e
11 Passive Floors
a
b
Exposed Floors
c
Slab (Perimeter Ft.)
d
Basement Floor
e
Partition Floors
f
g
Envelope Leakage
12 Infiltration
Semi-Tight
Heated & Cooled
Floor Area = Sq. Ft.
No. of Fireplaces
775
Number of Bedrooms
13 Internal Gains
Above Grade = Cu. Ft.
Occupants
1
2
460
Appliance - 2400 BTUH
2400
14 Sub Totals
15989
9343
1162
408
17150
11458
7D-T&B SA, RA in Closed Crawlspace or Unconditioned Basement
15 Duct Loss & Gain
R-Value = 6
Leakage Class .12/.24
0.073
Installed Square Feet of Surface or Default = 1
16 Ventilation
Combustion Air From Conditioned Space
19 Blower Heat Gain
Furnace
Supply
0.044
1
Return
1
50 Cfm (Max. for MJ8ae)
Water Heater
Manufacturer's performance data has no blower heat discount
1707
20 Total Sensible Loss or Gain
Latent Infiltration load for cooling
JTL engineering, pllc
Spokane Valley, WA 99206
509-413-7997
Mike@JTLengineering.net
400
Latent load for occupants
9116 E Sprague Ave., #457
21
Latent load for
plants
Small
Medium
1
1
Latent load for duct in unconditioned space
Large
30
116
Latent ventilation load for cooling
Total Latent Gain
546
MANUAL J8AE ● SUMMARY REPORT
Project Longwell Residence Upper Level
Mfg. Equipment Sensible Heat Ratio
0.75
Manual Overide Entry for Design CFM
600
Room Name
HEAT LOSS
HTG CFM
HEAT GAIN
CLG CFM
Family/Kitchenette
10901
381
6422
395
395
Bedroom 4
5316
186
3033
187
187
Bath 4
934
33
296
18
33
Room Envelope Totals
17150
600
9751
600
Total Area
Construction Components
79
Windows & Glass Doors
HEAT LOSS
HEAT GAIN
1895
11.05%
2058
17.96%
4.98%
Skylights
Wood & Metal Doors
852
Above Grade Walls
3932
22.93%
570
189
Partition Walls
1302
7.59%
238
1870
10.90%
1870
16.32%
Partition Floors
3677
21.44%
1471
12.84%
Infiltration
3313
19.32%
2.08%
Below Grade Walls
908
Ceilings
Partition Ceilings
Passive Floors
Exposed Floors
Slab Floors
Basement Floors
775
ACCA
Manual D
CFM
Internal Gains
Duct Loss & Gain
1162
6.78%
275
2.40%
2860
24.96%
408
3.56%
1707
14.90%
11458
100.00%
Ventilation
Blower Heat Gain
Total Sensible
17150
100.00%
Total Latent
546
Total Cooling Load
12004
Air Conditioning Contractors of America
Manual S (Residential Equipment Selection)
Project Information
Cooling Design Information
Name: Longwell Residence - Upper Level
Outdoor Design Temp:
City: Hayden Lake
State: ID
Altitude: 2125
Altitude Adjustment:
0.97
86
°F db
Summer
Outdoor Design Temp:
-1
°F db
Winter
Indoor Design Temp:
75
°F db
50
%RH
°F wb
63
Airflow Calculations
Manual J Load Calculations
Total Load
Sensible
Latent
SHR
12004
11458
546
0.955
Heat Loss
17150
Design TD for Airflow
17
Design Sensible CFM
613
OEM Information
Manufacturer:
Carrier
Furnace Model #: 59TP6A040E171112
Coil or Fan-Coil Model #: CNPHP2417ACA
Condenser Model #: 24ACC618A0030
AFUE:
96.0
SEER:
16.0
HSPF:
(A) Manufacturer's Cooling Performance Data
Entering Coil Temperature = 75 (F db)
Lower
CFM
Rated CFM @ Rated RA Temperature
600
Rated CFM @ Design RA Temperature
Rated CFM @ Rated RA Temperature
Return Air
(F wb)
(F db)
95
Latent BTUH
Outdoor Temperature =
Total BTUH
Sensible BTUH
SHR
67
18,100
12,600
5,500
0.696
63
14,100
13,000
1,100
0.922
62
13,100
13,100
1
(B) Manufacturer's Cooling Performance Data
Entering Coil Temperature = 75 (F db)
Higher
CFM
Rated CFM @ Rated RA Temperature
800
Rated CFM @ Design RA Temperature
Rated CFM @ Rated RA Temperature
Return Air
(F wb)
Outdoor Temperature =
Sensible BTUH
Total BTUH
95
(F db)
Latent BTUH
SHR
67
22,000
15,900
6,100
0.723
63
17,760
16,540
1,220
0.931
62
16,700
16,700
1
Outdoor Temperature = 95 (F db)
Sensible BTUH
Total BTUH
Latent BTUH
SHR
Manufacturer's Cooling Performance Data (Interpolated)
Design
CFM
Return Air
(F wb)
1,108
13,225
Excess Latent Capacity Calculation
Capacity @ Design CFM / RA (F wb)
+
612.7
63
Equipment Capacity as a % of Design
281
-
281
14,333
13,506
827
119.40%
117.87%
151.43%
Manufacturer's Heat Pump Data
Capacity
@ 47 °F db
Capacity
@ 17 °F db
Balance
Point
Supplemental
Heat Required
65.0
5.02
Manufacturer's Furnace Data
Input
Capacity
40,000
Output
Capacity
39,000
AFUE
96.5
Desired
Temp. Rise
55
0.923
Calculated
Airflow
657
0.942
Air Conditioning Contractors of America, Manual D, Third Edirtion
Effective Length Worksheet
Element
Supply Run ID Number
#1
Straight Run
Length
25
Trunk Length
Trunk Length
Trunk Length
Runout Length
Fittings
Group 1 ◄
Group 2 ◄
Group 3 ◄
Group 4 ◄
Group 8 ◄
Group 9 ◄
Group 11 ◄
Group 12 ◄
Other
Other
Other
Other
Other
Total Length
Design TEL
Element
Group
Letters
C
C
10
Effective
Length
35
40
A
40
1
25
Length
Effective
Length
Group
Letters
0
Effective
Length
Length
Group
Letters
Effective
Length
0
0
Length
Length
175
Return Run ID Number
#1
Length
10
Trunk Length
Trunk Length
Trunk Length
Runout Length
Group 5 ◄
Group 6 ◄
Group 7 ◄
Group 8 ◄
Group 10 ◄
Group 11 ◄
Group 12 ◄
Other
Other
Other
Other
Total Length
Design TEL
Group
Letters
175
Straight Run
Fittings
Length
Group
Letters
A
C
Effective
Length
20
35
65
Length
Group
Letters
Effective
Length
0
Group
Letters
Effective
Length
0
65
Group
Letters
Effective
Length
0
Air Conditioning Contractors of America, Manual D, Third Edition
Friction Rate Worksheet
Step 1) Manufacturer's Blower Data
External static pressure (ESP)
CFM from manufacturers tables
Fan Speed
Step 2) Component Pressure Losses (CPL)
Direct expansion refrigerant coil
Electric resistance heating coil
Hot water coil
heat exchanger
Low efficiency filter
High or mid-efficiency filter
Electronic filter
Humidfier
Supply outlet
Return grille
Balancing damper ◄
UV lights or other device
Total component losses (CPL)
Step 3) Available Static Pressure (ASP)
Step 4) Total Effective Length (TEL)
Step 5) Friction Rate Design Value (FR)
0.9
40
600
Med
IWC
Cooling
600
Med
0.18
0.45
0.03
0.03
0.03
0.72
0.18
240
0.08
IWC
IWC
Feet
IWC/100
ID
RT-1
RT-2
RT-3
RT-4
ID
RR-1
RR-2
RR-3
RR-4
RR-5
RR-6
RR-7
RR-8
RR-9
RR-10
ST-1
ST-2
ST-3
ST-4
ST-5
ST-6
ST-7
ST-8
ID
ID
SR-1
SR-2
SR-3
SR-4
SR-5
SR-6
SR-7
SR-8
SR-9
SR-10
SR-11
SR-12
SR-13
SR-14
SR-15
SR-16
SR-17
SR-18
SR-19
SR-20
1
2
3
4
5
Room ID
Family Room
Bedroom 4
Bath 4
6
9751
600
600
Supply-side Trunks
8
Return-side Runouts
9 10 11 12 13 14 15 16 17 18 19 20
Associated Supply Runs
Return-side Trunks
Associated Supply Runs
7
Associated Supply Runs
17151
H-Btuh
10901
5316
934
14
562
14
Dsn Cfm Round Size Velocity Final Size
Dsn Cfm Round Size Velocity Final Size
600
14
562
14
600
Dsn Cfm Round Size Velocity Final Size
614
Supply-side Runouts
C-Btuh
Htg Cfm Clg Cfm Dsn Cfm Round Size Velocity Final Size
6422
381
395
395
12
503
12
3033
186
187
187
8
535
8
296
33
18
33
4
375
4
Duct Sizing Worksheet 1
11
Width
Equivilent Rect. Duct
Height
Width
Equivilent Rect. Duct
Height
Width
14
11
14
Height
Equivilent Rect. Duct
Equivilent Rect. Duct
Height
Width
10
11
10
5
10
1
Air Conditioning Contractors of America, Manual D, Third Edition
Equivilent
Flex
Equivilent
Flex
14
14
Flex
Equivilent
Equivilent
Flex
12
9
5