Category 6A Shielded Cable Assemblies

Category 6A Shielded Cable Assemblies
1499828-X, 1499825-X, 1499826-X, 1499830-X, 1499829-X, 1499480-X,
1499827-X, 1499831-X, 1499832-X
Description
AMP NETCONNECT XG Category 6A shielded patch cable assemblies meet or exceed channel specifications of
ANSI/TIA/EIA-568-B.2-10 Category 6A and ISO/IEC 11801:2002/Amd 1:2008 Class EA up to 500 MHz when used as
a component in a properly installed AMP NETCONNECT XG F/UTP channel. The AMP NETCONNECT XG Category
6A F/UTP System complies with all of the performance requirements for current and proposed applications such as
Gigabit Ethernet (1000BASE-Tx), 10/100BASE-Tx, token ring, 155 Mbps ATM, 100 Mbps TP-PMD, ISDN, analog and
digital video, analog and digital voice (VoIP), and exceeds all requirements for IEEE 802.3an 10 Gigabit Ethernet on
all parameters.
AMP NETCONNECT XG Category 6A shielded patch cable assemblies are manufactured using patented techniques
that create consistent performance superior to standard cable assemblies. AMP NETCONNECT XG Category 6A
shielded cable assemblies are riser rated and constructed using colored, stranded cable and matching colored snag
less boots.
Specification (text in brackets [ ] requires a choice)
Category 6A shielded patch cable assemblies shall be constructed using modular plugs with 50µm gold-plated
contacts, and shall be wired to the T568A wiring pattern. Cable assemblies shall utilize colored cable and "snag less"
cable boots that match the color of the cable. Cable assemblies shall be constructed of stranded conductors which
shall be surrounded by a shield and covered with [black, gray, blue, green, red, white, yellow, orange or violet]
colored jacket. Cable assemblies shall meet all the requirements of TIA 568-B.2-10 as well as the performance
requirements listed in the following table:
[include Performance Characteristics tables from page 2].
Cable shall be independently tested for performance to the following specifications:
1. ANSI/TIA/EIA-568-B.2-10
2. ISO/IEC 11801:2002/Amd 1:2008
3. IEEE 802.3an
Cable assemblies shall be AMP NETCONNECT part number [1499828-X, 1499825-X, 1499826-X, 1499830-X,
1499829-X, 1499480-X, 1499827-X, 1499831-X or 1499832-X
(X denotes length, see part number table for details)].
Black
Gray
Blue
Green
Red
White
Yellow
Orange
Violet
1499828-X 1499825-X 1499826-X 1499830-X 1499829-X 1499480-X 1499827-X 1499831-X 1499832-X
Dash number (-X) specifies length in Feet.
©Copyright 2008 by Tyco Electronics Corporation. All Rights Reserved. AMP, AMP NETCONNECT, NETCONNECT, and Tyco are trademarks.
Specifications subject to change without notice.
Page 1 of 2
Category 6A Shielded Cable Assemblies
1499828-X, 1499825-X, 1499826-X, 1499830-X, 1499829-X, 1499480-X,
1499827-X, 1499831-X, 1499832-X
Frequency
(MHz)
Insertion
Loss (dB)
NEXT
(dB)
PSNEXT (dB)
ACRF
(dB)
PSACRF
(dB)
Return Loss
(dB)
Prop Delay
(ns/100m)
Prop Delay
Skew (ns)
TCL
(dB)
ELTCL / TCTL
(dB)
PSANEXT
(dB)
PSAACRF /
PSAFEXT (dB)
Channel Performance Characteristics (meet or exceed ANSI/EIA/TIA, ISO/IEC and IEEE requirements)
0.772
1
4
8
10
16
20
25
31.25
62.5
100
200
250
300
400
500
2.1
2.3
4.2
5.8
6.5
8.2
9.2
10.2
11.5
16.4
20.9
30.1
33.9
37.4
43.6
49.3
65.0
65.0
63.0
58.2
56.6
53.2
51.6
50.0
48.4
43.4
39.9
34.8
33.1
31.7
28.7
26.1
62.0
62.0
60.5
55.6
54.0
50.6
49.0
47.3
45.7
40.6
37.1
31.9
30.2
28.8
25.8
23.2
65.5
63.3
51.2
45.2
43.3
39.2
37.2
35.3
33.4
27.3
23.3
17.2
15.3
13.7
11.2
9.28
62.5
60.3
48.2
42.2
40.3
36.2
34.2
32.3
30.4
24.3
20.3
14.2
12.3
10.7
8.2
6.3
19.0
19.0
19.0
19.0
19.0
18.0
17.5
17.0
16.5
14.0
12.0
9.0
8.0
7.2
6.0
6.0
585.0
580.0
562.0
556.7
555.4
553.0
552.0
551.2
550.4
548.6
547.6
546.5
546.3
546.1
545.8
545.6
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
50.0
40.0
40.0
40.0
39.5
38.0
34.9
33.5
32.0
30.4
24.4
20.3
14.3
12.3
10.8
8.3
6.3
32.2
30.0
18.0
11.9
10.0
5.9
4.0
2.0
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
67.0
67.0
67.0
67.0
67.0
67.0
67.0
66.0
65.1
62.0
60.0
55.5
54.0
52.8
51.0
49.5
67.0
67.0
65.0
58.9
57.0
52.9
51.0
49.0
47.1
41.1
37.0
31.0
29.0
27.5
24.9
23.0
Technical Details
Materials
Conductors –
Insulation –
Jacket –
Boot –
Plug housing –
Terminals –
26 AWG, 7/34 stranded copper
Polyolefin
FR Polyolefin, 0.240 in nominal diameter
Elastomer Polyolefin
clear polycarbonate
Copper-tin-phosphor alloy with 50µm gold plating on selected area, gold flash over the
remainder, > 100µm nickel under plate
Electrical Characteristics
Capacitance –
Impedance –
Voltage –
Mechanical Characteristics
Operating Temperature –
Bending Radius –
Tensile Strength –
13.5 pf/ft. at 1 MHz
100 ohms ± 15%, 1 MHz to 100 MHz
150VAC max
-20 to 60ºC
The minimum bending radius is 8x outside diameter during installation and 4x the outside
diameter after installation.
50 N
Approvals
UL File Number E138034
UL 444
RoHS Compliant
FCC PART 68 SUBPART F
Specifications subject to change without notice.
Revised 06/08
http://www.ampnetconnect.com/thailand
©Copyright 2008 by Tyco Electronics Corporation. All Rights Reserved. AMP, AMP NETCONNECT, NETCONNECT, and Tyco are trademarks.
Specifications subject to change without notice.
Page 2 of 2