Installation Guide Cabinet Surface Mount for Dual

Installation Guide
Cabinet Surface Mount for Dual Displays
The purpose of this guide is to:
1. Describe procedures for installing Channel on cabinet top and mounting Dual Channel Column (page 2).
2. Describe the procedure for mounting the Dual Display Mounting Bar in the Column.
3. Describe mounting of displays
Parts Reference
The following parts and hardware are included with this installation kit (hardware not shown).
Item #
Description
Qty
1
Dual Channel Column, 18''
1
2
Cover Plate
1
3
1/4-20 x 5/8'' Flat Head Socket Cap Screw (FHSCS)
4
4
Channel, 13'' Seismic
1
5
Backing Plate, 13''
1
6
#10-32 x 1-1/4'' Flat Head Machine Screw (FHMS)
6
7
#10-32 x 1-1/4'' Pan Head Machine Screw (PHMS)
3
8
#10-32 x 1-1/2'' FHMS
6
9
#10-32 x 1-1/2'' PHMS
3
10
Dual Display Mounting Bar
1
11
Display Mounting Kit (includes instructions)
2
12
Spacer, M8031B 15'' Display
2
13
Spacer, M8033C 17'' Display
2
14
1/8'' Hex Wrench
1
15
5/32'' Hex Wrench
1
16
Channel Cover, 16'' L x 2'' W
2
17
Channel Cover, 12'' L x 1'' W
2
10
11
13
12
1
2
4
5
Tools Required
• Drill (not provided)
• 5/16'' drill bit (not provided)
• Phillips screwdriver (not provided)
• 1/8'' hex wrench (provided)
• 5/32'' hex wrench (provided).
WARNING! It shall be the responsibility of the installer to determine whether the horizontal channel
will support the weight of the Dual Channel Column and any mounted instruments or accessories.
Load capacity decreases as the load is extended laterally from the Mount. This Dual Channel Column
is not compatible with most anesthesia machine top plate applications.
DU-PH-0057-04 Rev A 1/10/08 GCX Corp. Page 1 of 6
Installing Horizontal Channel and on Cabinet Top
Installation Note: Hardware is provided for attaching Channel to cabinet top material from 3/4'' [18mm] to 1'' [25mm]
thick.
1. Using the Channel as a template, drill nine (9) holes through the cabinet top with a 5/16'' drill bit.
2. Select required length of screw (1-1/4'' or 1-1/2''), and fasten Channel to Backing Plate (through cabinet top) with six
(6) #10-32 FHMS (outer holes) and three (3) #10-32 PHMS (center holes).
#10-32 PHMS in Center Holes (3)
#10-32 FHMS in Outer Holes (6)
Drill Holes with 5/16'' Bit
Cabinet Top
Backing Plate
Mounting Dual Channel Column in Channel
1. Guide Channel Slide (bottom of Column) into Channel and move to desired mounting position.
2. Using the 1/8'' hex wrench provided, tighten four (4) socket set screws to secure Column position in Channel.
Set Screws (4)
DU-PH-0057-04 Rev A 1/10/08 GCX Corp. Page 2 of 6
Mounting the Dual Display Mounting Bar on the Dual Channel Column
1. Insert Channel Slide in top of Channel, move to mounting position, and tighten all set screws in Slide.
Insert Slide
Tighten Set Screws (2)
2. Using the 5/32'' hex wrench provided, fasten Cover Plate to top of Dual Channel Column with four (4) 1/4-20 x 5/8''
FHSCS (below). Installation Note: This step should be accomplished only after all devices and accessories have
been mounted in the front and rear channels.
1/4-20 x 5/8'' FHSCS (4)
Cover Plate
DU-PH-0057-04 Rev A 1/10/08 GCX Corp. Page 3 of 6
Mounting the Displays
Mount displays using hardware from the Mounting Kit for 75/100 VESA Compatible Flat Panel Displays (provided). This
installation kit includes a detailed installation guide for mounting the display.
Installation Note: A Spacer (provided) is required for mounting either an M8031B (15'') or M8033C (17'') display. Insert
appropriate Spacer and mount display as shown below. 15'' display: Use M4 pan head machine screws from Mounting
Kit for 75/100 VESA Compatible Flat Panel Displays. 17'' display: Use M4 pan head machine screws plus VESA
Mounting Adapter from Mounting Kit for 75/100 VESA Compatible Flat Panel Displays.
M8031B (15'') Display
Spacer
Spacer for 17'' Display
Spacer for 15'' Display
M4 x 12mm PHMS (4)
Remove and Discard Four (4) Existing
Screws from Display
M8033C (17'') Display
Spacer
Use M4 x 25mm PHMS (4) from Mounting
Kit for 75/100 VESA Compatible Flat Panel
Displays (FLP-0002-17)
VESA Mounting Adapter
M4 x 10mm PHMS (4)
(Mounting Plate to VESA
Mounting Adapter)
DU-PH-0057-04 Rev A 1/10/08 GCX Corp. Page 4 of 6
Cable Management
Cables
1. Cables may be routed through the rear of the Channel Slide.
2. A pass-through is provided in mid-channel to allow cables to be
routed to the rear of the Column.
3. Channel Covers (not shown) are provided for both the 2-inch and
1-inch wide Channels. Channel Covers serve both as an aesthetic
cover and may be used for cable management along the Channel.
After all equipment has been mounted, install Channel Covers in
accordance with separate installation guide.
Making Adjustments to the Display Bar
Horizontal Adjustment
The two (2) Display Mounts may be adjusted horizontally to accommodate two (2) flat panel displays with enclosures up
to 21'' in width (not diagonal measurement). Using a 1/2'' [13 mm] wrench, loosen the bolt on the bottom of the Display
Bar. Move display to desired position and tighten bolt. Note: This adjustment may affect both horizontal movement and
swivel tension of the display. Ideally, this adjustment would allow the display to swivel but not move horizontally.
Swiveling the Display
Swivel displays individually (limited to ± 15º) or swivel the
Display Bar, Arm, or Roll Stand.
Horizontal Adjustment
& Swivel Tension Bolt
Adjusting Swivel Tension
Using a 1/2'' [13 mm] wrench, tighten or loosen the Swivel
Tension Bolt as required to achieve desired tension. See
Horizontal Adjustment "Note" above.
Adjusting Tilt
Lever provides ratchet-style adjustment. Turn the Tilt
Adjustment Lever counterclockwise (CCW) to loosen. Grasp
display and tilt to desired angle. Turn Lever clockwise (CW) to
tighten and lock position
Tilt Adjustment Lever
Tilt Tension Screws (2)
Adjusting Tilt Tension
Using the 5/32'' hex key (provided), equally tighten or loosen
the two (2) Tilt Tension Screws. Once desired tilt tension is set,
use the Tilt Adjustment Lever to fine tune/lock the tilt position.
DU-PH-0057-04 Rev A 1/10/08 GCX Corp. Page 5 of 6
Routine Maintenance of the Mounting System
Periodically check all mounting hardware. Tighten as necessary for optimal operation.
Cleaning the Mounting Assembly
CAUTION: GCX makes no claims regarding the efficacy of the listed chemicals or processes as a means for controlling
infection. Consult your hospital’s infection control officer or epidemiologist. To clean or sterilize mounted instruments or
accessory equipment, refer to the specific instructions delivered with those products.
1. The mounting assembly may be cleaned with most mild, non-abrasive solutions commonly used in the hospital
environment (e.g. diluted bleach, ammonia, or alcohol solutions).
2. The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and
trichloroethylene.
3. Do not use steel wool or other abrasive material to clean the mounting assembly.
4. Damage caused by the use of unapproved substances or processes will not be covered by warranty. We recommend
testing of any cleaning solution on a small area of the arm that is not visible to verify compatibility.
5. Never submerge or allow liquids to enter the mounting assembly. Wipe any cleaning agents off the mounting assembly
immediately using a water-dampened cloth. Dry all parts thoroughly after cleaning.
DU-PH-0057-04 Rev A 1/10/08 GCX Corp. Page 6 of 6