KM 111M - Avinav Marketing Inc.

DIGITAL CLAMPMETER + MULTIMETER
MODEL KM 111M
An ISO 9001:2000 Company
9 FUNCTIONS 31 RANGES
FEATURES
— 3 ¾ digits 4,000 counts high resolution
W
NE
— Ultra-slim jaws to access tight places; 26mm conductor size
— Light weight < 140gm & small body to fit your hand
— Fully auto-ranging for ease of use; Fast measurements
— 600A AC Clamp-on + Multimeter ranges
— 600V AC/DC input protection on all functions
— High 0.5% DCV accuracy
— Data HOLD
KM 111M
— Fast 30ms MAX HOLD to capture In-rush currents
AUTO
— Relative Zero mode
— Measures non-invasive ACA Frequency via clamp jaws
— Line-level ACV Frequency measurements
H
028.4
Transient protection
6KV 1.2/50mS
lighting surge
m V
— Rugged Fire-retarded casing; Soft carrying pouch
— LVD EN61010-2-032 CAT III 600V
— EMC EN61326 (97/98A1) / EN 61000-4-2(95/00A2)/EN61000-4-3(02)
GENERAL SPECIFICATIONS
— Update Rate : 3 per second nominal
— Polarity : Automatic
— Low Battery : Below approx. 2.4V.
— Operating Temperature : 0OC to 40OC.
— Relative Humidity : Maximum relative humidity 80%
O
for temperature upto 31 C decreasing linearly to 50%
O
relative humidity at 40 C
— Altitude : Operating below 2000m
— Storage Temperature :-20OC ~ 60OC < 80% R.H.
(With Battery removed)
— Temperature Coefficient : Nominal 0.15 x (specified
O
O
O
O
O
accuracy) / C @ (0 C ~ 18 C or 28 C ~ 40 C), or
otherwise specified.
— Sensing : Average sensing .
— Overload Protections:
ACA Clamp-on jaws : AC 600A rms continuous.
+/mA & COM terminals : 600VDC / VAC rms
— Transient protection : 6.5KV (1.2/50mS surge) .
Preliminary Data
— Safety : Meets IEC61010-2-032 (2002), EN61010-2-032
(2002), UL61010B-2-032 (2003).
Measurement Category : III 600 Volts AC & DC.
— Pollution degree : 2
— E.M.C. : Meets En61326 (1997, 1998/A1), EN61000-4-2
(1995, 2000/A2), and EN61000-4-3 (2002)
In an RF field of 3 V/m :
Capacitance function is not specified.
Total Accuracy = specified Accuracy + 65 digits.
Other function ranges :
Total Accuracy = Specified Accuracy + 45 digits.
Performance above 3V/m is not specified.
— Power Supply : Single 3V coin Battery.
— Power Consumption : 2.8mA typical except that
3.3mA typical for current function.
— APO Timing : Idle for 30 minutes.
— APO Consumption : 5mA typical.
— Dimension : 190(L) x 63(W) x 32(H)mm
— Weight : Approx. 139gm.
— Accessories : Battery installed, Test lead pair,
Manual & Carrying case.
ELECTRICAL SPECIFICATIONS
Accuracy is ± (% reading digits + number of digits) or otherwise specified, at 23OC ± 5OC & less than 75% R.H.
DC VOLTAGE
Hz FREQUENCY
RANGE
ACCURACY
FUNCTION
400.0 mV
4.000 V
40.00 V
400.0 V
600
V
0.3% + 4d
400.0 mV
350 mV
10Hz ~ 2KHz
0.5% + 3d
4.000
V
4
V
5Hz ~ 40KHz
40.00
V
32
V
5Hz ~ 100KHz
400.0
V
200
V
5Hz ~ 100KHz
600
V
500
V
5Hz ~ 5KHz
400.0
A
60
A
40Hz ~ 400Hz
1.0% + 4d
NMRR : > 50dB @ 50/60Hz
CMRR : > 120dB @ DC, 50/60Hz; Rs=1KW
Input Impedance : 10 MW, 30pF nominal
(1000MW for 400.0mV range)
SENSITIVITY (SINE RMS)
RANGE
Display counts : 5000
Best Resolution : 0.001Hz
Accuracy : 0.5% + 4d.
OHMS
AC VOLTAGE (50Hz ~ 500Hz)
RANGE
4.000V
40.00V
400.0V
600V
ACCURACY
RANGE
ACCURACY
400.0W
0.8% + 6d
4.000KW
40.00KW
400.0KW
4.000MW
40.00MW
Open Circuit Voltage : 0.4VDC typical
1.5% + 5d
2.0% + 5d
CMRR : > 60dB @ DC to 60Hz, Rs=1KW
0.6% + 4d
1.0% + 4d
2.0% + 4d
Input Impedance : 10 MW, 30pF Nominal.
CAPACITANCE
RANGE
1)
ACCURACY
2) 3)
500.0 nF
5.000 mF
AC CURRENT (Clamp-on) (50Hz / 60Hz)
RANGE
40.00
A
ACCURACY
1.5% + 8d
400.0
A
1.5% + 8d
500.0 mF
3000 mF
1)
600
A
1.5% + 8d
2)
1)
Induced error from adjacent current-carrying
conductor : 0.05/A
2)
Specified accuracy is from 5% to 100% of range and for
measurements made at the jaw center. When the
conductor is not positioned at the jaw center, position
errors introduced are:
Add 2% to specified accuracy for measurements made
BEYOND jaw marking lines (toward jaw opening)
3)
Add 8d to specified accuracy @ reading < 10% of range.
Max Hold (where applicable)
Specified accuracy ± 50 digits for changes
> 25ms in duration.
3.5% + 6d
50.00 mF
1) 2) 3)
3)
Additional 50.00nF range accuracy is not specified.
Accuracies with film capacitor or better
Specified with battery voltage above 2.8V (approx. Half full battery).
Accuracy decreases gradually to 12% at low battery warning
voltage of approx. 2.4V.
DIODE TESTER
OPEN CIRCUIT VOLTAGE
TEST CURRENT (Typical)
0.25mA
<1.6 VDC
Audible Continuity Tester
Audible threshold : between 20W and 120W.
Note: All Specification are Subject to change.