PC & Logic AVR Series
Automatic Voltage Regulator For Stable Power Protection
Features
PC AVR series
LOGIC AVR series
• 800VA AVR
• 1000~2200VA AVR
• 4 outlets (4 AVR+surge)
• 6 outlets (4 AVR + surge & 2 surge only) for 1000VA
• Desk top and wall mountable design
• 10 outlets(5 AVR+ surge & 5 surge only) for 1200 VA/2200VA
• Resettable input overload protection circuit
• Dest top and wall mountable design
breaker
• Resettable input overload protection circuit breaker
• Automatically regulates high and low voltage
• Automatically regulates high and low voltage
• User-friendly visual indicators display
• Overheating protection
• RJ-11/45 telephone/fax/internet data line surge protection
• User-friendly visual indicators display
AVR-800
AVR-1000A
AVR-1200A/2200A
PC & LOGIC AVR SPECIFICATION
SERIES
PC AVR
MODEL
AVR-800
AVR-1000A
AVR-1200A
AVR-2200A
800VA / 400W
1000VA / 500W
1200VA / 600W
2200VA / 1100W
CAPACITY
LOGIC AVR
AC INPUT
Nominal Voltage
120Vac
120Vac / 230Vac
Input Voltage Range
96Vac ~ 140Vac
95Vac ~ 150Vac / 176Vac ~ 278Vac
Phase
1 Phase 2 Wires
1 Phase 2 Wires
50 / 60Hz (Auto Sensing)
50 / 60 Hz (Auto Sensing)
107Vac ~ 132Vac
108Vac ~ 129Vac / 205Vac ~ 246Vac
Frequency
AC OUTPUT
Output Voltage Range
Frequency
Outlets
PROTECTION
Surge Suppression
Network Surge
Suppression
50 Or 60Hz
50 / 60Hz
4 Outlets
(4 AVR + Surge)
6 Outlets
(4 AVR + Surge & 2 Surge Only)
10 Outlets
(5 AVR + Surge & 5 Surge Only)
N/A
84 Joules
110 Joules
None
RJ-11
RJ-11 / RJ-45
Overload
Manual Reset Circuit Switch
Short Circuit
Manual Reset Circuit Switch
Physical
Dimension (W x H x D)
Net Weight
28 〡
www.MarusonUSA.com
80 x 77 x 220mm
3.1 x 3.0 x 8.7in
200 x 140 x 70mm
7.9 x 5.5 x 2.8in
1.2kg / 2.6lb
1.49kg / 3.3lb
227 x 160 x 78mm
8.9 x 6.3 x 3.1in
1.65kg / 3.6lb
2.3kg / 5.1lb
Micro AVR Series
Automatic Voltage Regulator For Stable Power Protection
Features
• 800VA~5000VA automatic voltage regulator
• Input voltage and output voltage meter display
(3000VA~5000VA)
• 6 Outlets for 800VA~2000VA & 8 outlets (3000VA
~5000VA)
• Resettable circuit breaker for overload protection
• Selectable delay time setting (2/10/30 seconds)
(3000VA ~5000VA)
• Cable management (800VA~2000VA)
• RJ - 11/45 combo telephone/fax/network line
protection port (3000VA ~5000VA)
• Optional coaxial cable line protection
• Optional USB charging ports (800VA~2000VA)
AVR-3000VA/4000VA/
5000VA
AVR-800VA/1200VA/
2000VA
MICRO AVR SPECIFICATION
MODEL
CAPACITY
AVR - 800VA
AVR - 1200VA
AVR - 2000VA
AVR-3000VA
AVR-4000VA
AVR-5000VA
800VA / 400W
1200VA / 600W
2000VA / 1000W
3000VA / 1500W
4000VA / 2000W
5000VA /2500W
AC INPUT
Nominal Voltage
220/230/240Vac
120Vac Or 220Vac
Input Voltage Range
161Vac ~ 288Vac
95Vac ~ 150Vac Or 172Vac ~ 276Vac
Phase
Frequency
1 Phase 2 Wires
50 / 60Hz (Auto Sensing)
AC OUTPUT
Output Voltage Range
207Vac ~ 253Vac
108Vac ~ 129Vac Or 207Vac ~ 252Vac
5VDC (±2%)
N/A
DC OUTPUT
Output Voltage Range
OUTLETS
Surge only
3 PCS
N/A
AVR + Surge Protection
3 PCS
8 PCS
PROTECTION
Surge Suppression
N/A
240 Joules
Network Surge Suppression
RJ-11 / RJ-45
Overload
Manual Reset Circuit Switch
Short Circuit
Manual Reset Circuit Switch
METER
Input Voltage Meter
N/A
Showing Input Voltage
Output Voltage Meter
N/A
Showing Output Voltage After Stabilized
80 x 120 x 280mm
3.1 x 4.7 x 11in
157 x 150 x 250mm
6.2 x 5.9 x 9.8in
PHYSICAL
Dimension (H x W x D)
Net Weight
1.4kg
3.1lb
1.7kg
3.8lb
2.3kg
5.1lb
5kg
11lb
6kg
13.2lb
7kg
15.4lb
Power Solutions for All Your Needs 〡 29