Market Central - AV-iQ

Market Central ®
www.secureswitch.com
500 Business Center Drive Pittsburgh, PA 15205 USA
412.494.2800
CAGE 1BGJ7
SwitchMaster® R5000 Series
Ultra-Compact Ganged A/B Switching System
JUNE 2013
Part Numbers
2U HIGH, 19” RACK MOUNT CHASSIS
CONTROLLER CARD – BASIC RS232/MANUAL (FRONT & REAR CARD SET)
CONTROLLER CARD – SNMP/ ETHERNET SUPPORT (FRONT & REAR CARD SET)
CONTROLLER CARD – SNMP EXPANSION (FRONT & REAR CARD SET)
EXTERNAL P/S ADAPTER CARD (SINGLE SLOT)
DC POWER SUPPLY CARDS (-48 VOLT) (FRONT & REAR SET)
SINGLE DC OUTPUT POWER SUPPLY CARD
POWER SUPPLY CARD (INCLUDES 2 EXTERNAL AC/DC POWER MODULES 5000761)
EXTERNAL AC/DC POWER SUPPLY MODULE
AC POWER SUPPLY CARD - REQUIRES TWO SLOTS (FRONT & REAR CARD SET)
RJ45 A/B SWITCH CARD - Supports up to 1 GbE
CAT6 RJ45 A/B SWITCH CARD - Supports up to 10 GbE
NON-LATCHING FIBER OPTIC A/B SWITCH CARD, SC CONNECTORS
LATCHING FIBER OPTIC A/B SWITCH CARD, SC CONNECTORS
LATCHING FIBER OPTIC A/B SWITCH CARD, ST CONNECTORS
NON-LATCHING FIBER OPTIC A/B SWITCH CARD, ST CONNECTORS
DB9 A/B SWITCH CARD
DB15 A/B SWITCH CARD
DB25 A/B SWITCH CARD
LATCHING F-TYPE A/B SWITCH CARD
NON-LATCHING F-TYPE A/B SWITCH CARD
RS232/DB25 SIGNAL MONITORING A/B SWITCH CARD
RS530/DB25 SIGNAL MONITORING A/B SWITCH CARD
BLANK FRONT/REAR PANEL (2 REQUIRED PER EMPTY SLOT )
5000722
5000764
5000765
5000790
5000752
5000767
5000754
5100740
6000761
5000763
5000725
5000782
5000726
5000772
5000737
5000735
5000736
5000729
5000730
5000795
5000796
5000856
5000857
5000766
(lead-free versions of the above items are also available by changing the part # from 5xxxxxx to 6xxxxxx)
Market Central Inc., 500 Business Center Drive, Pittsburgh, PA 15205
Phone: (412) 494-2800, Fax: (412) 494-5550, www.secureswitch.com CAGE Code 1BGJ7
©
Copyright 2010. Market Central, Inc. All rights Reserved.
Market Central® and SwitchMaster® are registered trademarks of Market Central, Inc.
Market Central, Inc.
1. Specifications
Connectors:
RJ45 A/B SWITCH CARD – (3) RJ45 connectors
CAT6 RJ45 A/B SWITCH CARD – (3) CAT6 RJ45 connectors
FIBER OPTIC A/B SWITCH CARDS – (3) Duplex fiber optic SC or ST receptacles
DB9 A/B SWITCH CARD – (3) DB9 female connectors (male optional)
DB15 A/B SWITCH CARD – (3) DB15 female connectors (male optional)
DB25 A/B SWITCH CARD – (3) DB25 female connectors (male optional)
F-TYPE A/B SWITCH CARD – (3) female f type connectors
CONTROLLER CARD – (1) RJ45, (2) RJ11
Indicators:
A/B SWITCH CARDS – (2) LED, one for A, one for B
CONTROLLER CARD – (2) LED, one for power, one for status
Switches:
A/B SWITCH CARDS – (1) momentary toggle switch, (1) 8-position dip-switch
CONTROLLER CARD – (1) momentary toggle switch, (1) 8-position dipswitch, (1) momentary push-button switch,
and (1) key-lock switch.
Power:
RJ45 A/B SWITCH CARD – 12 VDC, 40 mA normal, additional 92 mA max while switching.
CAT6 RJ45 A/B SWITCH CARD – 12 VDC, 40 mA normal, additional 92 mA max while switching.
FIBER OPTIC A/B SWITCH CARD, NON-LATCHING – 12 VDC, 40 mA in A position, 120 mA max in B
position, additional 18.4 mA max while switching.
FIBER OPTIC A/B SWITCH CARD, LATCHING – 12 VDC, 40 mA normal, additional 80 mA max while
switching.
DB9 A/B SWITCH CARD – 12 VDC, 40 mA normal, additional 92 mA max while switching.
DB15 A/B SWITCH CARD – 12 VDC, 40 mA normal, additional 147 mA max while switching.
DB25 A/B SWITCH CARD – 12 VDC, 40 mA normal, additional 239 mA max while switching.
F-Type A/B SWITCH CARD- 12VDC, 40 mA normal, additional 52 mA max while switching.
CONTROLLER CARD – 12 VDC, 100 mA normal, additional 250 mA with network module.
The rack may be powered with either a (90 – 264 VAC, 47 – 63 Hz) two slot internal AC supply card, or a (36 – 76
VDC) two slot internal DC supply card. Both types of supplies provide 12 VDC @ 4.2A max output. Two power
supplies may be used in single rack for redundancy. External power supply options are also available.
Rack Size:
RACK – 18 card slots, 3.5” H x 19” W x 12.5” D (including handles and connectors)
RJ45 A/B SWITCH CARD – one slot (0.937 inches wide)
CAT6 RJ45 A/B SWITCH CARD – one slot (0.937 inches wide)
FIBER OPTIC A/B SWITCH CARDS – one slot (0.937 inches wide)
DB9 A/B SWITCH CARD – two slots (1.875 inches wide)
DB15 A/B SWITCH CARD – three slots (2.812 inches wide)
DB25 A/B SWITCH CARD – three slots (2.812 inches wide)
F-TYPE A/B SWITCH CARD – one slot (0.937 inches wide)
CONTROLLER CARD – one slot (0.937 inches wide)
INTERNAL AC POWER SUPPLY CARD - two slots (1.875 inches wide)
INTERNAL DC POWER SUPPLY CARD - two slots (1.875 inches wide)
Environment:
TEMPERATURE
HUMIDITY
ALTITUDE
0° to 50° C operating, -40° to 70° C non-operating
0 to 95% non-condensing
40,000 ft maximum
R5000 A/B SWITCHING SYSTEM
Page 2 of 21
Market Central, Inc.
2. Introduction
The R5000 SwitchMaster® Switching System is a 2U 19” rack style chassis containing multiple A/B Switch Cards.
Each switch card connects port A or port B to port C, through latching telecommunication relays (except the fiber
optic switches described below). The R5000 rack has 18 slots and can accept any mix of switch cards, power supply
cards, and one Controller Card (one required per chassis). Any type of card can be installed in any slot in the R5000
rack, allowing for maximum flexibility of cable routing etc. If a single slot power supply card (such as the 5100740)
is used, the rack can hold up to 16 A/B Switch Cards, and a Controller Card. Each A/B Switch Card can be
individually switched, or the entire rack can be switched from the Controller Card. The Controller Card has a keyed
switch to enable and disable manual switching (disables the front panel toggle switches on the Controller Card and
on each switch card). The Controller Card has two RJ11 ports which provide for serial communications to the rack,
and also allow multiple racks to be daisy-chained together to create a single system that can be controlled by the first
rack in the daisy chain. The Controller Card also provides remote switching capabilities via an RS232 interface or
using a +/- 12 VDC signal from a remote toggle switch.
The Controller Card consists of a front pc board assembly and a rear pc board assembly set, and is available in three
different versions (RS232, SNMP/Ethernet, and SNMP Expansion). The RS232 version supports Rack and System
Gang Switching using the manual toggle switches on the Controller Card and A/B Switch Cards, and supports RS232
communications on the gang-in and gang-out connectors. The RS232 Controller Card allows system level (all cards
in all racks) switching with serial commands (see section 5.1 for additional info). The SNMP/Ethernet capable
version features a RS232 terminal interface which can be used to control individual A/B switch cards, a rack of A/B
switch cards, or system of daisy-chained racks, and to configure the Ethernet port parameters (see section 7 for
additional info). The Ethernet port allows the rack or system of daisy-chained racks (containing the SNMP
Expansion Controller Card) to be controlled using SNMP commands, Telnet commands, or via a built-in html based
web browser interface. There can only be one SNMP/Ethernet capable Controller Card in a daisy-chained system of
racks, and it must be in the first rack in the system. If daisy-chaining one or more racks from an SNMP/Ethernet
capable rack, the additional racks must have an SNMP Expansion Controller Card, which is compatible with the
message format from the SNMP/Ethernet Controller Card.
Fiber Optic A/B Switch Cards are available in both latching and non-latching styles. Please refer to the part number
chart on the cover of this manual for specific part numbers for latching and non-latching fiber optic switch cards.
Latching switch cards retain their selected connections even when power is lost or removed. Non-latching fiber optic
switch cards fall back to the “Port C to Port A” connection when power is removed or fails, regardless of which port
is selected prior to the removal or failure of power When power is re-applied, the optical switch in a non-latching
fiber optic switch card will reconnect port C to the port (A or B) that was selected prior to the loss of power. The
non-latching styles of fiber optic switch cards are often used when a fall-back or “failover” style of connection
scheme is desired in the event of power failure.
R5000 A/B SWITCHING SYSTEM
Page 3 of 21
Market Central, Inc.
3. Configuration
3.1 A/B Switch Card Configuration
Figure 3.1.1 – Typical A/B Switch Card Front & Rear Panels
Each A/B Switch Card has an 8-position DIP switch, used to set the card’s address. Switch position 1 is the least
significant bit, and position 8 is the most significant bit. Set each switch ON (as marked) for a '0', and OFF for a '1'.
Card address 1 for example, would be DIP switch position 1 OFF, and positions 2-8 ON. Card addresses within a
rack, or within a system of daisy-chained racks must be unique and one card MUST be addressed 1. Card address
0x00 is reserved and must not be used. A typical approach is to set rack 0x01, card addresses to 0x01 through 0x10
from left to right within the rack. In the second rack 0x02, set the card addresses to 0x11 through 0x20 and so on.
The Controller Card communicates with the individual switch cards using a multi-drop scheme. If two A/B cards
within the same rack or daisy-chained system of racks have the same address, both will try to respond at the same
time, causing communication errors. Thus, the maximum number of A/B Switch Cards in a daisy-chained system of
racks is limited to 255 switch cards.
3.2 Controller Card Rear PC Board Configuration
8
7
6
5
4
3
2
1
1
2
3
4
5
6
1
2
3
4
5
6
Figure 3.2.1 – Controller Card Rear Panel Outline
R5000 A/B SWITCHING SYSTEM
Page 4 of 21
Market Central, Inc.
The Controller Card rear pc board assembly has two jumpers for shielding and grounding options. The two 3position jumpers are positioned such that pin 1 is toward the card edge connector, and pin 3 is toward the RJ11
connectors. Each 3-position jumper has a 2-position shunt, used to connect two of the three positions together.
Table 3.2.1 – Controller Card Rear PC Board Jumper Settings
Jumper
RJ45 Shield
Connected to Frame Ground *
Open
Power Supply Ground
100 Ohm Connection to Frame Ground *
Direct Connection to Frame Ground
* Factory Default Positions
W1
W2
Pin 1 to Pin 2
Pin 2 to Pin 3
Pin 1 to Pin 2
Pin 2 to Pin 3
Table 3.2.2 – RJ45 (Optional Ethernet Port) Pin Assignment
Pin
1
2
3
6
Signal Name
Transmit Pair
Transmit Pair
Receive Pair
Receive Pair
Signal Direction
Output
Output
Input
Input
Table 3.2.3 – RJ11 GANG-IN Port Pin Assignment
Pin
5
4
3
2
Signal Name
Signal Ground
Transmit Data / V+
Receive Data / VSystem Control (OPEN,+12,-12)
Signal Direction
Not Applicable
Output / Output
Input / Output
Input and Output
Note: The functions of pins 3 and 4, on the GANG-IN port, are set using jumpers on the front card. They can be
configured as TXD and RXD for serial communication, or as V+ and V- to control the system control input with a
remote toggle switch. The connections to V+ and V- are through 1 K ohm resistors. The System Control signal is
used as an input and an output. As an Input signal it is normally open. This input is driven to +12 VDC to switch
the system to A, and is driven to –12 VDC to switch the system to B. As an output, this signal is driven to +10 VDC
when the user initiates a system switch to A, and is driven to –10 VDC when the user initiates a system switch to B.
Table 3.2.4 – RJ11 GANG-OUT Port Pin Assignment
Pin
5
4
3
2
Signal Name
No Connection
Transmit Data
Receive Data
Signal Ground
Signal Direction
Not Applicable
Output
Input
Not Applicable
Note: A standard RJ11 male/male crossover cable is required to connect from the gang-out port on one rack to the
gang-in port on the next.
R5000 A/B SWITCHING SYSTEM
Page 5 of 21
Market Central, Inc.
3.3 Controller Card Front PC Board Configuration
The Controller Card front pc board has an 8-position dipswitch and four jumpers for user configurable options. The
four 3-position jumpers are positioned such that pin 1 is toward the front panel, and pin 3 is toward the rear of the
card. Each 3-position jumper has a 2-position shunt, used to connect two of the three positions together.
Table 3.3.1 – Controller Card Front PC Board Jumper W1 and W2 Settings
Jumper
Gang-In Pin 3
Connected to TXD *
Connected to V+ through 1K
Gang-In Pin 4
Connected to RXD *
Connected to V- through 1K
W1
W2
Pin 1 to Pin 2
Pin 2 to Pin 3
Pin 1 to Pin 2
Pin 2 to Pin 3
* Factory Default Setting
Jumpers W1 and W2 function as a pair to configure the gang-in port. Refer to table 3.2.3 for the GANG-IN port pin
assignment. Connect to TXD and RXD to support RS-232 serial communications, or connect to V+ and V- through
1 K ohm resistors to control the system control input with a remote toggle switch. Note that the serial port is
required for setup of the network parameters.
Table 3.3.2 – Controller Card Front PC Board Jumper W4 and W5 Settings
Jumper
Input Port Source
Normal RS-232 *
Optional SNMP/Ethernet version ~
Input Port Source
Normal RS-232 *
Optional SNMP/Ethernet version ~
W4
W5
Pin 1 to Pin 2
Pin 2 to Pin 3
Pin 1 to Pin 2
Pin 2 to Pin 3
* Factory Default Setting – RS232 and SNMP Expansion versions
~ Factory Default Setting – SNMP/Ethernet version
Jumpers W4 and W5 function as a pair to configure the input port source. It should not be necessary to change these
jumpers from their factory set positions. These jumpers configure the source for communications to the internal
processor on the Controller Card. If you have a Controller Card with an optional SNMP/Ethernet network module
installed, both jumpers should be set to connect pins 2 and 3. Otherwise both jumpers should be set to connect pins
1 and 2 to allow the processor to communicate with the RS-232 signals from the GANG-IN port.
The 8-position dipswitch has a different function depending on the type of Controller Card. Refer to Table 3.3.3 for
the RS232 version only. The SNMP/Ethernet and SNMP Expansion versions use this dip switch to set the rack
address.
Table 3.3.3 – Controller Card Dip Switch Settings (RS232 Version Only)
Switch
Security Character
0
1
2
3
SW2-1
SW2-2
SW2-3
SW2-4
0N
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
R5000 A/B SWITCHING SYSTEM
SW2-5
SW2-6
Page 6 of 21
Market Central, Inc.
4
5
6
7
8
9
:
;
<
=
>
?
Security Code Enabled
Security Code Disabled
Safe Mode Enabled
Safe Mode Disabled
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF *
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF *
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF *
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF *
ON
OFF *
ON
OFF *
* Factory Default Setting
When the security code is enabled, the selected security character must precede any serial commands received at the
gang in port of the first rack in the system. The security code must be disabled on all following racks. Refer to
section 5.1 for a list of applicable serial commands.
Safe mode operation prevents switching commands from the gang-in port, allowing only status request commands.
This provides a level of protection against corrupt or spurious data causing unintended switching in an application
where only status is required of the gang-in port. Set safe mode OFF to allow A/B switching from the gang-in serial
port. Safe mode must be disabled (OFF) on racks connected to the gang-out port of another R5000 rack, to allow
system switching to occur (otherwise system switching will be blocked from higher level racks).
Dip switch positions 7 and 8 are reserved for future development, and should be left in the OFF position.
For the SNMP/Ethernet and SNMP Expansion Controller Cards, the 8-position dipswitch SW2 is used to define the
Controller Card (or rack) address. Rack addresses within the system must be unique, but may be repeated in other
systems. The rack address space and card address space are separate, i.e. racks and cards can have the same address.
It is necessary that address “00” be left unused, and recommended that the racks be assigned addresses “01” through
“FF”. The network Controller Card communicates with other Controller Cards using a multi-drop scheme. If two
racks within the same system have the same address, both will try to respond at the same time, causing
communication errors. Switch position 1 is the least significant bit, and position 8 is the most significant bit. Set
each switch ON (as marked) for a '0', and OFF for a '1'. Address 1 for example would be position 1 OFF, and
positions 2-8 ON.
R5000 A/B SWITCHING SYSTEM
Page 7 of 21
Market Central, Inc.
4. Installation
The A/B Switch Cards consist of a single card, which is inserted from the rear of the rack. The Controller Card
consists of a front card and a rear card.
4.1 Controller Card Rear PC Board Installation
4.1.1 Using the card guides, carefully slide the rear card into the rack, until it makes connection to the 8-position
socket on the rack backplane.
4.1.2 Secure the rear card to the rack at the top and bottom of the card, using the screws provided.
4.1.3 Using standard RJ11 male/male crossover cable, connect the gang out from one rack to the gang in connector
on the next if multiple racks are to be daisy-chained together. Repeat this step until all racks have been
connected.
4.2 Controller Card Front PC Board Installation
4.2.1 Using the card guides, carefully slide the front card into the rack, until it makes connection to the 36-position
card edge connector on the rear card.
4.2.2 Secure the front card to the rack at the top and bottom of the card, using the screws provided.
4.3 A/B Switch Card Installation
4.3.1 From the rear of the rack, using the card guides, carefully slide the card into the rack, until it makes
connection to the 8-position socket on the rack backplane.
4.3.2 Secure the rear card to the rack at the top and bottom of the card, using the screws provided.
4.3.3 If not already in place, secure the front panel to the rack, using the screws provided.
5. Operation
When power is applied to the Controller Card, the PWR LED should illuminate.
When power is applied to the A/B Switch Card, either the "A" LED or the "B" LED should illuminate to indicate the
currently connected port.
When the Key-Lock switch on the Controller Card is OFF, the manual toggle switches on the Controller Card and all
the A/B Switch Cards in the rack will be disabled. Note that the rack may still switch in response to a command
received on the RS232 Gang-In port, or the Ethernet port.
When the Key-Lock switch on the Controller Card is ON, the manual toggle switches in the rack function normally.
The toggle switches on the A/B Switch Cards are used to switch only that card. Hold the switch in the “A” position
to connect Port A to Port C. The “A” LED will illuminate when the switch operation has been completed. Release
the switch when switching has finished. Hold the switch in the “B” position to connect Port B to Port C. The “B”
LED will illuminate when the switch operation has been completed. Release the switch when switching has finished.
The toggle switch on the Controller Card is used to switch all cards in the rack, and is operated in the same fashion
as the individual toggle switches on the A/B Switch Cards. To switch an entire system of daisy-chained racks, hold
the “system” push-button while operating the toggle switch on the Controller Card.
The Controller Card STAT LED should blink under the following conditions:
The front panel control switches are used to initiate a “rack” or “system” level switching operation.
The Controller Card received a switch command on the RS232 Gang-In port or the Ethernet port.
R5000 A/B SWITCHING SYSTEM
Page 8 of 21
Market Central, Inc.
5.1 RS-232 Serial Switching
The RS232 version of the Controller Card allows the user to remotely switch all of the cards in a rack or system of
daisy-chained racks using the serial commands listed in Table 5.1.1 below. The SNMP/Ethernet version of the
Controller Card does not support the one character serial commands listed in Table 5.1.1 below, but instead uses the
enhanced console commands listed in Section 7 of this manual. Also note that the data rate of the Gang-In port
increases to 9600 bps for the SNMP/Ethernet version of Controller Card. The SNMP Expansion Controller Card
does not support the one character serial commands listed in Table 5.1.1 below, but will pass these commands
through to the cards in the rack and to subsequent racks in the system.
Table 5.1.1 – RS-232 System Switching Commands (RS232 version of Controller Card)
Command
A <CR>
B <CR>
S <CR>
Description
Switch “system” to A
Switch “system” to B
Request “status”
Notes:
1. The RS232 terminal device connected to the RS232 version of Controller Card’s Gang-In port must be set to
2400 Baud, No Parity, 8 Data Bits, 1 Stop Bit. Connect using the supplied DB9 to RJ11 adapter and RJ11 to
RJ11 crossover cable.
2. The one character commands above are CASE SENSITIVE, and must be followed by a carriage return. Refer
to table 3.3.3 for a list of optional “security” characters which may precede these commands.
3. Note: These RS232 commands only allow control of the entire system, thus the status of all cards in the system
should be the same. Therefore, only one card (address 0x01) in the first rack will respond to the “S” status
command. If there is no card with address 0x01 in the first rack, there will be no response to the status
command.
5.2 “SYSTEM” Switching Using the Gang-In System Control Signal
The System Control signal is used as an input and an output. As an Input signal it is normally open. This input is
driven to +12 VDC to switch the system to A, and is driven to –12 VDC to switch the system to B. The input circuit
requires approximately 1 mA to operate properly.
As an output, this signal is driven to +10 VDC when the user initiates a system switch to A, and is driven to –10
VDC when the user initiates a system switch to B. To protect the output circuits, the output goes through a 1 K ohm
resistor. Therefore, this output should not be used to drive a large load.
The gang-in connector normally accepts RS-232 input signals, but can be configured to supply +12 VDC and –12
VDC. Refer to table 3.3.1 for jumper configuration information. These +12 VDC and –12 VDC outputs are
provided through 1 K ohm resistors, and therefore should not be used to drive large loads. These outputs are
provided to allow system switching, using only a remote contact. It is recommended that a momentary toggle switch
be used.
Figure 5.2.1 System Switching, Using a Remote Momentary Toggle Switch
R5000 A/B SWITCHING SYSTEM
Page 9 of 21
Market Central, Inc.
6. Network Setup
To perform the initial setup of an SNMP/Ethernet version of Controller Card, you will need a serial terminal capable
of 9600 baud, no parity, 8 data bits, and 1 stop bit. Connect this terminal to the GANG-IN port using the supplied
DB9 to RJ11 adapter and RJ11 to RJ11 crossover cable.
RJ11 PIN
3
4
2
Table 6.1 – DB9 to RJ11 Adapter Pin Assignment
SIGNAL
DIRECTION
RECEIVED DATA
TO TERMINAL
TRANSMITTED DATA
FROM TERMINAL
GROUND
DB9
2
3
5
Apply power to the R5000 rack. The SNMP/Ethernet version of Controller Card requires 30-40 seconds to boot up,
while performing self tests and configuring.
After this process is complete you will see a sign-on message displayed on the serial console, i.e.
R5000 Network Agent Version 2.6 Aug 2006
Copyright (C) 2006 Market Central, Inc.
All rights reserved
www.mctech.com
System starting ...
console ready.
>
At this point the Controller Card is ready for the low level configurations necessary before you will be able to
communicate with the network port using TCP/IP. You will need to enter an IP address, subnet mask, and gateway
address, as well as read and write SNMP community names if using SNMP, a telnet password for telnet access, or a
web password for browser access. These parameters must be saved into non-volatile memory, and then the system
must be reset to allow it to reconfigure with the new settings. Any time one or more of these parameters is changed,
they must be saved followed by a system reset. The following shows a typical setup session. Change the entered
parameters to suit your application requirements. All the console level commands available are described in detail in
section 7.
>set ipaddress 192.168.1.200
OK
>set subnetmask 255.255.255.0
OK
>set readcommunityname public
OK
>set writecommunityname private
OK
>save
OK
>reset
restarting …
After the system reinitializes, you will again be greeted by the sign-on message as before. At this time you can attach
a 10base-T CAT5 cable between the Controller Card’s Network port and an available port on your hub, and the
SNMP/Ethernet version of Controller Card will respond to SNMP and HTTP messages at the assigned IP address.
See the MIB Path Summary for a list of SNMP variables and their functions.
R5000 A/B SWITCHING SYSTEM
Page 10 of 21
Market Central, Inc.
7. Console Commands (SNMP/Ethernet version of Controller Card)
When the R5000 powers up, it will send a sign-on message followed by a prompt character “>” to your serial
terminal device, set at 9600 baud, no parity, 8 data bits, and 1 stop bit. After each command is executed, the
associated response from the R5000 will be issued followed by a prompt character. For systems where the console
port is being commanded by software, the software should wait for this prompt character before sending each and
every command to the R5000.
It is possible to switch one or all of the switch ports to the A or B connection state using the appropriate serial
commands. It is also possible to query the position of any one of the switch ports in a particular rack using serial
commands. The RS232 serial interface is NOT affected by the position of the front panel keylock switch – it will act
upon and respond to commands it receives even if the keylock switch is in the DISABLE position.
The following commands are available from the RS232 console prompt of an SNMP/Ethernet version of Controller
Card. All commands are case insensitive, although several variable parameters are case sensitive (read/write
community names and web password). GET, SET, SYSTEM, RACK, and PORT can all be abbreviated by the first
letter of the command. This allows shorthand entry of switching commands to be compatible with the serial only
control version of the Controller Card.
GET ALL
Displays all parameters and settings. An example output is shown here.
System Status: X
IP Address: 192.168.1.200
Subnet Mask: 255.255.255.0
Gateway IP Address: 192.168.1.1
Web Enable: Enabled
Web Password: mctech
Web Timeout: 300
Web Port: 80
Telnet Enable: Enabled
Telnet Password: mctech
Telnet Timeout: 80
Telnet Port: 23
Read Community Name: public
Write Community Name: private
Authentication Trap: Disabled
R5000: 2.6 Aug 2006, V1.1 10/2003
SNMP Manager Table:
1: 192.168.1.113
2: 192.168.1.115
3: 192.168.1.149
GET VERSION
Displays the software revision of the network module and Controller Card.
R5000: 2.6 Aug 2006, V1.1 10/2003
GET SYSTEM
This command is not supported in the R5000. If this command is issued to the R5000 it will respond with the
following:
System Status: X
R5000 A/B SWITCHING SYSTEM
Page 11 of 21
Market Central, Inc.
SET SYSTEM A[B]
Sets all of the A/B Switch Cards in the entire system (all connected racks) to position A or B.
GET RACK N
This command is not supported in the R5000. If this command is issued to the R5000 it will respond with the
following:
Rack Status: XXXXXXXXXXXXXXXX
SET RACK N A[B]
Sets all of the A/B Switch Cards in the addressed rack N (1-255) to position A or B.
GET PORT N
Displays the status of switch card N (1-255). The response will be “Port Status: A”, “Port Status: B”, or “Port
Status: no response” if there isn’t a switch card present at address “N”.
SET PORT N A[B]
Sets the addressed card N (1-255) to position A or B.
GET POWER N
Displays the status of the power supplies for rack N. If only one power supply is being used to power the rack or if
one of the supplies in a dual powered rack is down, the response will be “Power Status: One Supply Down”. If two
supplies are used and both are operational, the response will be “Power Status: Two Supplies”.
SET IPADDRESS X.X.X.X
GET IPADDRESS
Set or display the current IP address of the network module. Any change will not become permanent until a SAVE
and RESET operation sequence is performed.
SET SUBNETMASK X.X.X.X
GET SUBNETMASK
Set or display the current subnet mask of the network module. Any change will not become permanent until a SAVE
and RESET operation sequence is performed.
SET GATEWAY X.X.X.X
GET GATEWAY
Set or display the gateway router’s IP address. Any change will not become permanent until a SAVE and RESET
operation sequence is performed.
R5000 A/B SWITCHING SYSTEM
Page 12 of 21
Market Central, Inc.
SET READCOMMUNITYNAME string
GET READCOMMUNITYNAME
Set or display the current read or write community name as specified. Note that in general these are case sensitive
fields. Any change will not become permanent until a SAVE and RESET operation sequence is performed.
SET WEBENABLE ON[OFF]
GET WEBENABLE
Set or display the current state of web based access. The network module will not accept any HTTP requests when
web enable is off. Any change will not become permanent until a SAVE and RESET operation sequence is
performed.
SET WEBPASSWORD string
GET WEBPASSWORD
Set or display the current web password. Note that this is a case sensitive field. Any change will not become
permanent until a SAVE and RESET operation sequence is performed.
SET WEBTIMEOUT seconds
GET WEBTIMEOUT
Set or display the current web timeout in seconds. After a period of inactivity of this many seconds, the network
module will request a login. Note that the web timeout cannot be disabled, it can however, be set arbitrarily large.
SET WEBPORT N
GET WEBPORT
Set or display the current web port number. Changing the web port number from the default can be used to provide
an additional level of security. Any change will not become permanent until a SAVE and RESET operation
sequence is performed.
SET TELNETENABLE ON[OFF]
GET TELNETENABLE
Set or display the current state of telnet based access. The network module will not accept any telnet requests when
telnet enable is off. Any change will not become permanent until a SAVE and RESET operation sequence is
performed.
SET TELNETPASSWORD string
GET TELNETPASSWORD
Set or display the current telnet password. Note that this is a case sensitive field. Any change will not become
permanent until a SAVE and RESET operation sequence is performed.
SET TELNETTIMEOUT seconds
GET TELNETTIMEOUT
Set or display the current telnet timeout in seconds. After a period of inactivity of this many seconds, the network
module will disconnect any current telnet session. Note that the telnet timeout cannot be disabled, it can however, be
R5000 A/B SWITCHING SYSTEM
Page 13 of 21
Market Central, Inc.
set arbitrarily large.
SET TELNETPORT N
GET TELNETPORT
Set or display the current telnet port number. Changing the telnet port number from the default can be used to
provide an additional level of security. Any change will not become permanent until a SAVE and RESET operation
sequence is performed.
SET AUTHENTICATIONTRAP ON[OFF]
GET AUTHENTICATIONTRAP
Set or display the current state of authentication error traps. Authentication traps will be generated when this
parameter is set to ON, and not when OFF. Note that this setting only affects the trap generation, and not how the
network module handles an authentication failure. An authentication failure generally means that an SNMP access
was attempted with an incorrect community name. Any change will not become permanent until a SAVE and RESET
operation sequence is performed.
SET MANAGER N X.X.X.X
Set SNMP manager N (1-16) IP address.
Up to 16 SNMP MANAGER IP addresses can be entered for destinations of trap messages. Trap messages will be
sent to all enabled MANAGER IP addresses. To remove an entry from the list, set the IP address to 0.0.0.0.
SNMP Manager Table:
1: 192.168.1.113
2: 192.168.1.115
3: 192.168.1.149
4: 192.168.1.100
GET MANAGER N
Display SNMP manager N (1-16) IP address.
GET MANAGER
Display all SNMP manager IP addresses.
SAVE
Save settings for next startup. All settings are stored in NV memory and restored upon power on. Any changes will
not become permanent until a SAVE and RESET operation sequence is performed.
RESET
Causes a network system reboot and reloads all parameters from stored settings. The network module takes 30-40
seconds to reboot completely.
R5000 A/B SWITCHING SYSTEM
Page 14 of 21
Market Central, Inc.
?
HELP
Displays a list of commands.
R5000 CONSOLE COMMANDS:
GET
ALL (display all parameters)
GET
VERSION (display software versions)
GET[SET]
SYSTEM [A/B] (control all system ports)
GET[SET]
RACK N [A/B] (control single rack ports)
GET[SET]
PORT N [A/B] (control single port)
GET
POWER N (display power status)
GET[SET]
IPADDRESS [X.X.X.X]
GET[SET]
SUBNETMASK [X.X.X.X]
GET[SET]
GATEWAY [X.X.X.X]
GET[SET]
READCOMMUNITYNAME [string]
GET[SET]
WRITECOMMUNITYNAME [string]
GET[SET]
WEBENABLE [ON/OFF]
GET[SET]
WEBPASSWORD [string]
GET[SET]
WEBTIMEOUT [N] (seconds)
GET[SET]
WEBPORT [N]
GET[SET]
TELNETENABLE [ON/OFF]
GET[SET]
TELNETPASSWORD [string]
GET[SET]
TELNETTIMEOUT [N] (seconds)
GET[SET]
TELNETPORT [N]
GET[SET]
AUTHENTICATIONTRAP [ON/OFF]
GET[SET]
MANAGER N [X.X.X.X] (0.0.0.0 to disable an entry)
GET
MANAGER (display all SNMP managers)
SAVE
save settings for next startup
RESET
restart (use after SAVE)
R5000 A/B SWITCHING SYSTEM
Page 15 of 21
Market Central, Inc.
8. Ethernet Interface (SNMP/Ethernet version of Controller Card)
The network module on the SNMP/Ethernet version of Controller Card also allows access to the enhanced console
commands listed in section 7 through either a telnet connection or a web browser interface. When enabled (see SET
WEBENABLE command) accessing the default page by typing the Controller Card’s IP address in the URL line of
your web browser (index.html) will present the following page:
Web Interface Version 1.0
Copyright (c) 2007, Market Central Inc.
All rights reserved.
www.mctech.com
Please logon:
Password:
Submit
Figure 8.1 Logon Screen
After successfully entering the correct web password (see SET WEBPASSWORD command) you will get the
following page.
Web Interface Version 1.0
Copyright (c) 2007, Market Central Inc.
All rights reserved.
www.mctech.com
Command console:
Enter new command:
Send Command
Logoff
Figure 8.2 Initial Command Screen
At this point you may enter any valid console command listed in section 7 into the text box and click “Send
Command” to execute. The following is an example result of the GET ALL command.
R5000 A/B SWITCHING SYSTEM
Page 16 of 21
Market Central, Inc.
Web Interface Version 1.0
Copyright (c) 2007, Market Central Inc.
All rights reserved.
www.mctech.com
Command console:
Output from last command...
System Status: X
IP Address: 192.168.1.30
Subnet Mask: 255.255.255.0
Gateway IP Address: 192.168.1.1
Web Enable: Enabled
Web Password: mctech
Web Timeout: 300
Web Port: 80
Telnet Enable: Enabled
Telnet Password: dataman
Telnet Timeout: 80
Telnet Port: 23
Read Community Name: public
Write Community Name: private
Authentication Trap: Disabled
R5000: 2.9 JUN 2007, V1.1 10/2003
SNMP Managers:
1: 192.168.1.105
Enter new command:
Send Command
Logoff
Figure 8.3 Example Command Results Screen
The SNMP/Ethernet version of Controller Card will only allow 1 telnet or web access session. To free up a session
without waiting for the web timeout, click “Logoff”. For this reason, the web timeout should be set to a workable
time. Resetting the unit will clear the current web session.
R5000 A/B SWITCHING SYSTEM
Page 17 of 21
Market Central, Inc.
9. SNMP MIB Path Summary
NOTE: The MIB contains definitions that do not apply to every product in the R5000 family.
[internet] – 1.3.6.1
[private] – 1.3.6.1.4
[enterprises] – 1.3.6.1.4.1
[mctech] – 1.3.6.1.4.1.9477
[mctech] – 1.3.6.1.4.1.9477
Market Central, Inc. private enterprise number
[mcAgent] – 1.3.6.1.4.1.9477.1
Market Central, Inc. SNMP Agent
[abSwitchSystem] – 1.3.6.1.4.1.9477.1.4
A/B Switch System
[abSystemGangPort] – 1.3.6.1.4.1.9477.1.4.1
[abRackTable] – 1.3.6.1.4.1.9477.1.4.2
[abRackIndex] – 1.3.6.1.4.1.9477.1.4.2.1.1.RackIndex
[abRackGangPort] – 1.3.6.1.4.1.9477.1.4.2.1.2.RackIndex
[abRackKeyStat] – 1.3.6.1.4.1.9477.1.4.2.1.3.RackIndex
[abRackPowerStat] – 1.3.6.1.4.1.9477.1.4.2.1.4.RackIndex
[abRackSoftwareVersion] – 1.3.6.1.4.1.9477.1.4.2.1.5.RackIndex
[abRackName] – 1.3.6.1.4.1.9477.1.4.2.1.6.RackIndex
[abRackCards] – 1.3.6.1.4.1.9477.1.4.2.1.7.RackIndex
[abSwitchTable] – 1.3.6.1.4.1.9477.1.4.3
[abSwitchIndex] – 1.3.6.1.4.1.9477.1.4.3.1.1.SwitchIndex
[abSwitchPort] – 1.3.6.1.4.1.9477.1.4.3.1.2.SwitchIndex
[abSwitchSoftwareVersion] – 1.3.6.1.4.1.9477.1.4.3.1.3.SwitchIndex
[abSwitchName] – 1.3.6.1.4.1.9477.1.4.3.1.4.SwitchIndex
R5000 A/B SWITCHING SYSTEM
Page 18 of 21
Market Central, Inc.
A/B Switch System SNMP Variable Definitions:
[abSystemGangPort] – 1.3.6.1.4.1.9477.1.4.1
A/B Switch System gang port. This variable is used to control all A/B Switch Cards in the
system. A system may consist of up to 255 racks, each rack containing up to 16 A/B Switch
Cards. It is write only.
[abRackTable] – 1.3.6.1.4.1.9477.1.4.2
A/B Switch Rack variable table. This variable is not directly accessible.
[abRackIndex] – 1.3.6.1.4.1.9477.1.4.2.1.1.RackIndex
A/B Switch Controller “Rack” address. The A/B Switch Controller address is set via an eight
position dip switch on the card. Each A/B Switch Controller in the system MUST have a unique
address, in the range of 0x01 to 0xFF hex. Address 0x00 is invalid, and must not be used.
This is a read only variable.
[abRackGangPort] – 1.3.6.1.4.1.9477.1.4.2.1.2.RackIndex
A/B Switch Rack gang port. This variable is used to control all A/B Switch Cards in a rack. A
rack may contain up to 16 A/B Switch Cards. It is write only.
[abRackKeyStat] – 1.3.6.1.4.1.9477.1.4.2.1.3.RackIndex
A/B Switch Rack Key-Lock Switch Status. This is a read only variable. This variable can be
used to determine if the Key-Lock Switch is in the OFF or ON position. The front panel
switches in the rack are disabled when the Key-Lock Switch is in the OFF position. The A/B
Switches will still respond to switch control signals and commands from the GANG-IN and
GANG-OUT ports.
[abRackPowerStat] – 1.3.6.1.4.1.9477.1.4.2.1.4.RackIndex
A/B Switch Rack Power Status. This is a read only variable.
The 2U A/B Switch controller rack may contain one or two power supplies. If one power supply
is installed and operating, the Power Status will report “OneSupply”. If two power supplies are
installed and both are operating, the Power Status will report “TwoSupplies”. If two power
supplies are installed and one is off line, the Power Status will report “One Supply Down”.
[abRackSoftwareVersion] – 1.3.6.1.4.1.9477.1.4.2.1.5.RackIndex
A/B Switch Controller Software Version. This is a read only variable, and is limited to a
maximum of 14 characters.
[abRackName] – 1.3.6.1.4.1.9477.1.4.2.1.6.RackIndex
A/B Switch Controller Identification String. The string is limited to a maximum of 14 characters.
[abRackCards] – 1.3.6.1.4.1.9477.1.4.2.1.7.RackIndex
A/B Switch Rack Card Status, One character for each of the sixteen cards in the rack. This
variable is present for compatibility with other A/B switching systems. It is read only and will
respond “NA”.
[abSwitchTable] – 1.3.6.1.4.1.9477.1.4.3
A/B Switch Rack variable table. This variable is not directly accessible.
R5000 A/B SWITCHING SYSTEM
Page 19 of 21
Market Central, Inc.
[abSwitchIndex] – 1.3.6.1.4.1.9477.1.4.3.1.1.SwitchIndex
A/B Switch “Card” address.
On a 2U A/B Switch System, the switch card address is set via an eight position dip switch on
the card. Each 2U A/B Switch cards in the system MUST have a unique address, in the range
of 0x01 to 0xFF hex. Address 0x00 is invalid, and must not be used. This is a read only
variable.
[abSwitchPort] – 1.3.6.1.4.1.9477.1.4.3.1.2.SwitchIndex
A/B Switch Card port. This variable is used to control the A/B Switch Card selected port. When
set to A, the switch will connect port A to port C. When set to B, the switch will connect port B
to port C. If the addressed A/B Switch Card is not present, you will not get a response.
[abSwitchSoftwareVersion] – 1.3.6.1.4.1.9477.1.4.3.1.3.SwitchIndex
A/B Switch Card Software Version. This is a read only variable, and is limited to a maximum of
14 characters.
On a 2U A/B Switch System, the A/B Switch cards have software. Therefore, this variable may
be different, depending on the software version on each card.
[abSwitchName] – 1.3.6.1.4.1.9477.1.4.3.1.4.SwitchIndex
A/B Switch Card Identification String. The string is limited to a maximum of 14 characters.
R5000 Switch system SNMP trap definitions:
All traps carry the sysObjectld (1.3.6.1.2.1.1.2) variable, whose value is 1.3.6.1.4.1.9477.1.
Coldstart – generic trap 0
This trap is sent during a power on initialization and reboot of the SNMP controller. It carries the
sysDescr variable (1.3.6.1.2.1.1.1).
AuthenticationFailure – generic trap 4
This trap is sent as a result of an authentication failure in processing an SNMP request.
Generally an authentication failure occurs as a result of an SNMP request with an invalid
community name. It carries the IpRequester variable.
abRackKeyLockChange – specific trap 1
This trap is sent when the key switch is changed on a rack. It carries the abRackKeyStat
variable.
abRackGangSwitchChange – specific trap 2
This trap is sent when a rack gang switch occurs. It carries the abRackGangPort variable.
abSystemGangSwitchChange – specific trap 6
This trap is sent when a system gang switch occurs. It carries the abSystemGangPort variable.
abRackPowerStatChange – specific trap 7
This trap is sent when the rack power supply status changes. It carries the abRackPowerStat
variable.
R5000 A/B SWITCHING SYSTEM
Page 20 of 21
Market Central, Inc.
WARRANTY LIMITATION OF REMEDIES AND LIABILITY
WARRANTY Market Central warrants to the original purchaser only that the products which are the
subject of this Contract will be free of defects in workmanship and materials, under normal service and
use, for a period of one (1) year from date of sale. Products which have been changed or altered in any
manner from their original design, or which are improperly or defectively installed, tested, serviced or
used, are not covered by this warranty. If any alleged failure to conform to this warranty shall arise during
a period of one (1) year from date of sale, Market Central shall, upon prompt, written notice and
compliance by Customer with such instructions as Market Central shall provide with respect to the return
of allegedly defective products or parts, correct such non-conformity by repair or replacement, or by the
refund of the purchase price or applicable portion thereof, at Market Central’s sole discretion. Correction
in the foregoing manner shall constitute a complete fulfillment of all obligations and liabilities of Market
Central with respect to said products. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF
ANY AND ALL OTHER WARRANTIES , WHETHER WRITTEN, ORAL , IMPLIED OR STATUTORY,
INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE; AND MARKET CENTRAL EXPRESSLY DISCLAIMS ANY SUCH
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
LIMITATION OF REMEDY. If any claim shall arise with respect to any alleged non-conforming product,
Market Central's sole obligation and Customer's sole and exclusive remedy shall be the repair or
replacement of said allegedly defective product or component or the refund of the applicable portion of the
purchase price, at Market Central's sole discretion and at no cost to Customer, in accordance with the
warranty provisions of the preceding paragraph. SAID REMEDY SHALL BE CUSTOMER'S SOLE AND
EXCLUSIVE REMEDY WITH RESPECT TO ANY ALLEGED NON-CONFORMING PRODUCT OR
OTHER CLAIM AS TO THE CONDITION OF ANY PRODUCT OR COMPONENT, WHETHER IN THE
NATURE OF A CLAIM FOR BREACH OF WARRANTY, NEGLIGENCE, TORT, STRICT LIABILITY,
PRODUCT LIABILITY WITH RESPECT TO DESIGN AND/OR MANUFACTURE, OR OTHERWISE.
LIMITATIONS OF LIABILITY. In no event will Market Central be liable for any incidental, consequential,
special or indirect losses or damages arising out of or in connection with the Contract, its performance or
breach thereof, including without limitation any and all losses and damages arising out of or related to
costs of removal and reinstallation of any item, loss of goodwill, loss of profits, delay and loss of use.
MARKET CENTRAL'S LIABILITY WITH RESPECT TO ANY CLAIM OF ANY KIND FOR ANY LOSS OR
DAMAGE SHALL NOT IN ANY EVENT EXCEED THE PRICE ALLOCABLE TO THE PRODUCT OR
UNIT THEREOF WHICH GIVES RISE TO THE CLAIM; AND MARKET CENTRAL SHALL NOT BE
LIABLE FOR ANY PENALTIES, PUNITIVE DAMAGES OR EXEMPLARY DAMAGES OF ANY KIND OR
DESCRIPTION.
Federal Communications Commission (FCC) Statement
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in
accordance with the instruction manual, may cause interference to radio communications. It has been
tested and found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection
against such interference when the equipment is operated in a commercial environment. Operation of
this equipment in a residential area is likely to cause interference, in which case the user at his own
expense will be required to take whatever measures may be required to correct the interference.
®
Market Central is a registered trademark of Market Central, Inc. All rights reserved.
©
Copyright 2010. Market Central, Inc. All rights Reserved.
R5000 A/B SWITCHING SYSTEM
Page 21 of 21