TES ELECTRICAL ELECTRONIC CORP.
1
QUALITY & RELIABILITY
QUALITY
&
RELIABILITY
TES is a professional test instrument manufacturer dedicated to all kinds of hand held equipment. Our goal is to
provide top quality products to fit in each customers
needs.
Our company was founded in 1988 with an initial gross
investment of 1,000,000 USD and the products line was
focused on low cost testers with basic functions.
Through we had built up a lot of designing know-how in the
first two years in that specific area, we decided to upgrade our products line to high end digital testers. In order
to provide the top quality products, the SMT equipments and fully automatic assembly lines were quickly
adopted in the company. With determination and efforts, our focus of products line has been gradually shifted
TES ELECTRICAL ELECTRONIC CORP.
to top quality digital testers.
2
QUALITY & RELIABILITY
Because of the increasing population of personal computer, we had implemented data recording and computer
linking capability on several high end products. And we also began to provide environmental monitoring and
medical instruments.
Now TES has become a corporation with more than 100 employees and with an annual revenue of 10,000,000
USD. We have an excellent R&D team to develop and design
new products and customized products according to the
Our products are sold all over the world and that makes a big
population of happy customers. If you are interested in any of
our products or looking for some information, fell free to
contact us directly. It will be an honor for us to serve your
needs.
TES ELECTRICAL ELECTRONIC CORP.
required specifications.
QUALITY & RELIABILITY
3
Index
Air Quality Monitor
TES-5321 / 5322
Air Quality Monitor ........................................................................................................... 7
Particle Counter
TES-5110
TES-5200
Particle Counter ............................................................................................................... 7
Particle Mass Counter ..................................................................................................... 7
Sound Level Meter
TES-1150 / 1151
Digital Sound Level Meter ............................................................................................... 8
Thermo / Hygro / Barometer
TES-1160 / 1161
Thermo / Hygro / Barometer ........................................................................................... 8
Chroma Meter
TES-136
Chroma Meter .................................................................................................................. 8
Luminance Meter
TES-137
Luminance Meter ............................................................................................................. 9
Sound Analyzer
TES-1358C
TES-1358E
Sound Analyzer ............................................................................................................... 9
Sound Analyzer ............................................................................................................... 9
Clamp Meter
TES-3900 / 3901
TES-3910
Clamp Meter (1000A) .................................................................................................... 10
Trms Clamp Meter (DC/AC 1000A) ............................................................................... 10
Multimeter
TES-2900
TES-2950
True RMS Multimeter ..................................................................................................... 11
LCR Trms Multimeter ..................................................................................................... 11
Transformer Turns Ratio Meter
Prova 1660
Transformer Turns Ratio Meter ...................................................................................... 12
Color Meter
TES-135A
Color Meter .................................................................................................................... 12
Luminous Flux Meter
TES-133
Luminous Flux Meter ...................................................................................................... 12
PV Analyzer
Prova 200A/200A-24/210/218 PV Analyzer .................................................................................................................... 13
Prova 1011
PV System Analyzer ...................................................................................................... 13
Solar Power Meter
TES-132
TES-1333 / 1333R
Solar Power Meter (Data logging) ................................................................................. 14
Solar Power Meter .......................................................................................................... 14
Solar Power Development System
TES-SS1
Solar Power Development System ................................................................................ 14
Multi-input Thermometer / Datalogger
Prova 800 / 830
TES-1384
Multi-input Thermometer / Datalogger ........................................................................... 15
4 Input Thermometer / Datalogger ................................................................................. 15
Anemometer
AVM-01/03
AVM-05/07
AVM-301/303/305
Anemometer ................................................................................................................... 16
Flow Anemometer .......................................................................................................... 16
Anemometer ................................................................................................................... 16
Hot-Wire Anemometer
TES-1340 / 1341
Hot-Wire Anemometer .................................................................................................... 17
TES ELECTRICAL ELECTRONIC CORP.
Battery Tester
4
TES-32
TES-33
Battery Impedance Tester .............................................................................................. 17
Battery Capacity Tester ..................................................................................................17
Calibrator
Prova iCal
Prova 100
Prova 123
Prova 125
TES-1356
Documenting Multifunction Calibrator ........................................................................... 18
4-20 mA Loop Calibrator ................................................................................................ 18
Multifunction Calibrator .................................................................................................. 19
Temperature Calibrator .................................................................................................. 19
Sound Level Calibrator ................................................................................................... 19
Capacitance Meter
TES-1500
Capacitance Meter ......................................................................................................... 20
CO / CO2 Analyzer
TES-1370
TES-1372/1372R
CO2 Analyzer ................................................................................................................. 20
CO Analyzer ................................................................................................................... 20
Conductivity & pH/ORP Meter
TES-1380
TES-1381
QUALITY & RELIABILITY
pH/ORP/Temp. Meter (RS-232) ..................................................................................... 21
Conductivity & pH/ORP Meter ....................................................................................... 21
Index
DC / AC Current Clamp
CM-01
CM-02
CM-05
CM-07
Prova 11
Prova 1200
Prova 15
Prova 2000 / 2003
TES-3010 / 3012
TES-3040
TES-3050
TES-3082
TES-3092
DC/AC Clamp Meter ....................................................................................................... 21
AC/DC Clamp Meter Automotive Clamp ........................................................................ 22
AC/DC Current Probe ..................................................................................................... 22
TRMS AC/DC Clamp Meter ........................................................................................... 22
AC/DC mA TRMS Clamp Meter ..................................................................................... 22
AC/DC Clamp Meter ....................................................................................................... 23
AC/DC mA Current Probe .............................................................................................. 23
AC/DC Clamp Meter ....................................................................................................... 23
Prof. Clamp Meter .......................................................................................................... 23
AC Clamp Meter ............................................................................................................. 24
TRMS AC/DC Clamp Meter ........................................................................................... 24
TRMS AC/DC Clamp Meter ........................................................................................... 24
AC/DC Clamp Meter (700A AC/DC) .............................................................................. 24
Earth / Ground Tester
Prova 5601
TES-1605
TES-1700
Clamp-on Ground Resistance Tester ............................................................................ 25
Digital Earth Tester ......................................................................................................... 25
Earth Resistance Tester ................................................................................................. 25
EMF Tester
TES-1390/1392
TES-1393/1394S
TES-92
TES-593
EMF Tester (Single axis) ................................................................................................ 26
EMF Tester (3 axis) ........................................................................................................ 26
Electro Smog Meter ........................................................................................................ 26
Electro Smog Meter (3 axis) .......................................................................................... 27
Flexible Clamp Meter
AFLEX 3030
AFLEX 3001/3002
AFLEX 3060
Flexible AC Current Probe ............................................................................................. 27
Flexible AC Current Clamp ............................................................................................ 27
Flexible AC Current Probe (6000A, 36) ....................................................................... 28
Harmonic Clamp Meter
Prova 19/21/23
Prova 6603/6605
Leakage and Harmonics Tester ..................................................................................... 28
Power and Harmonics Tester ......................................................................................... 28
Humidity Temp. Meter
TES-1260
TES-1360A
TES-1361C
TES-1362
TES-1364/1365
Humidity Temperature Meter ......................................................................................... 29
Humidity/Temperature Meter ......................................................................................... 29
Datalogging Humidity/Temperature Meter ..................................................................... 29
Printing Humidity/Temperature Meter ............................................................................ 30
Datalogging Humidity/Temperature Meter ..................................................................... 30
Leakage Current Tester
CM-03
Leakage Current Tester ................................................................................................. 30
Insulation Tester
TES-1600
TES-1601
TES-1604
TES-3660
Insulation Tester ............................................................................................................. 31
Auto Ranging Insulation Tester ...................................................................................... 31
Datalogging Insulation Tester (RS-232) ........................................................................ 31
Autoranging Insulation Tester ........................................................................................ 32
LAN Cable Tester
TES-45A
TES-46
LAN Cable Tester ........................................................................................................... 32
LAN Cable Tester ........................................................................................................... 32
Light Meter
Light Meter ...................................................................................................................... 33
Light Meter ...................................................................................................................... 33
Datalogging Light Meter (RS-232) ................................................................................. 33
Light Meter ...................................................................................................................... 34
Light Meter Pro. (RS-232) .............................................................................................. 34
Loop / PSC Tester
TES-1800
Loop / PSC Tester .......................................................................................................... 34
RCD Tester
TES-1900
Digital RCD Tester ......................................................................................................... 35
Milli / Micro-Ohmmeter
Prova 700 / 710
Milli / Micro-Ohmmeter ................................................................................................... 35
Multimeter
Prova 803
Prova 901/903
TES-2620
TES-2700
TES-2712
TES-2732A
Precision Multimeter (Mobile Bench-top) DMM ............................................................. 35
Precision Multimeter (Mobile Bench-top) DMM ............................................................. 36
3 3/4 digits TRMS Multimeter ......................................................................................... 36
Auto Ranging Multimeter ................................................................................................36
LCR Multimeter ............................................................................................................... 37
Data Logger Multimeter (RS-232) .................................................................................. 37
TES ELECTRICAL ELECTRONIC CORP.
TES-1330A/1332A/1334A
TES-1335
TES-1336A
TES-1337
TES-1339/1339R
QUALITY & RELIABILITY
5
Index
Power Supply
Prova 8000
Prova 8500
Programmable Power Supply ........................................................................................ 37
Electric Energy-Saving Tester ....................................................................................... 38
Power Analyzer
TES-3600
AFLEX 3003/3005
AFLEX 6300
Prova 6830A+01/02/03/3006/3009
WM-01/03
Prova 6200
3 phase Power Analyzer ................................................................................................ 38
Flexible VA Harmonics/Power Quality Tester ................................................................ 38
Graphic Power Quality Analyzer .................................................................................... 39
Power and Harmonics Analyzer ..................................................................................... 39
Power Analyzer / Datalogger ......................................................................................... 39
Graphic Power Quality Analyzer .................................................................................... 40
Power Clamp Meter
Prova 6600
Prova 6601
TES-3063
TES-3079M
3 Phase / 1 Phase Power Clamp ................................................................................... 40
3 Phase PF Power Clamp .............................................................................................. 40
Datalogging Power AC/DC Clamp Meter ....................................................................... 41
Power/HVAC Trms Clamp Meter (1000A) ..................................................................... 41
Sound Level Meters
TES-1350A
TES-1351B
TES-52A
TES-1352S
TES-1353S
TES-1354/1355
TES-1357
TES-1358C
TES-1358E
TES-1359
Sound Level Meter ......................................................................................................... 41
Sound Level Meter ......................................................................................................... 42
Sound Level Meter ......................................................................................................... 42
Programmable Sound Level Meter ................................................................................ 42
Integrating Sound Level Meter ....................................................................................... 43
Noise Dosimeter ............................................................................................................. 43
Precision Sound Level Meter ......................................................................................... 43
Sound Analyzer ............................................................................................................. 44
Sound Analyzer ............................................................................................................. 44
Sound Level Meter ......................................................................................................... 44
Tachometer
RM-1000
RM-1500/1501
Digital optical Tachometer ..............................................................................................45
Digital Tachometer ......................................................................................................... 45
Thermometers
TES-1300/1303
TES-1304
TES-1306
TES-1307
TES-1311A
TES-1312A
TES-1314
TES-1315/1316
TES-1317/1317R
TES-1318
TES-1319A
TES-1384
TES-1326/1327/1327K
TES-1327K-USB
Thermometer .................................................................................................................. 45
Printing Thermometer ..................................................................................................... 46
K/J Thermometer ............................................................................................................ 46
Datalogging K/J Thermometer ....................................................................................... 46
Thermometer .................................................................................................................. 47
Thermometer .................................................................................................................. 47
K.J.E.T.R.S.N Thermometer .......................................................................................... 47
Datalogging K.J.E.T.R.S.N Thermometer ...................................................................... 48
RTD Thermometer .......................................................................................................... 48
RTD Thermometer (Dual Channels) .............................................................................. 48
Thermometer (Type K) ................................................................................................... 49
4 Input Thermometer / Datalogger ................................................................................. 49
Infrared / K Type Thermometer ...................................................................................... 49
Infrared / K Type Thermometer ...................................................................................... 50
Transformation Device
VT-01
Transformation Device for LCD Display ........................................................................ 50
Watt Clamp Meter
TES ELECTRICAL ELECTRONIC CORP.
Prova 400
6
AC/DC TRMS Watt Clamp Meter ................................................................................... 50
Optional Accessories ........................................................................................................................... 51
QUALITY & RELIABILITY
TES-5321 / 5322 TES-5110 TES-5200
Air Quality Monitor
TES-5321 / 5322 Air Quality Monitor
Features
Preset warning point of buzzer
Fine particulate matter (PM2.5)
alarm, LED and alarm output.
measurement.
Mix gases (VOCs-Volatile organic
compounds) measurement. High
sensitivity to H2, C2H5OH,
C4H10, CO and CH4. (5322)
Temperature and Humidity
measurements.
Health index (0 ~ 9) detection and
alarm.
PM2.5 and VOCs time weighted
average reading.
Data hold and MAX/MIN with time
stamp function.
Six color LED indication air quality
at good / moderate / poor.
Manual data memory and read
function.
Auto data logger function. (5322)
USB Interface. (5322)
Micro SD CARD 4GB (5322)
PM2.50 to 500g/m3
VOCs1 to 50ppm (5322)
Humidity1% to 99%R.H.
Temperature-20 ~ +60 (-4
~ +140)
Particle Counter
TES-5110 Particle Counter
Features
Applications:
6 particle size channels0.3m 0.5m 1.0m 2.0m 5.0m
10m
Integrated temperature / humidity
sensor (no need for external add-on).
Flow rate 2.83 L/minute (0.1 CF /
minute).
Rechargeable battery provides up to
4 hours of continuous operation
(charge time 2 hours).
Buffer function allows storing and
redisplay of up to 500 measurement
data sets. (SD Card Memory)
Password protection for measurement settings.
Monitoring clean rooms.
Indoor air quality investigations.
Monitoring growing rooms.
Testing filter seals.
Locating particle contamination sources.
Monitoring particle size distributions.
Sample flow rate: 2.83L/min
Max. Particle concentration: 70,000
particles/L (coincidence loss max. 5%)
Buffer function: Store and recall values
for up to 500 measurements
PC interface: USB interface
SD storage device
TES-5200 Particle Mass Counter
Applications:
Particle mass & particle counter in a
single handheld unit.
Six mass ranges (PM1, PM2.5, PM4,
PM7, PM10, and TSP) and Eight
particle sizes (0.5mm, 0.7mm, 1.0mm,
2.5mm, 4.0mm, 5.0mm, 7.0mm,
10mm).
User K-factors setting for special
particulate with different densities.
Integrated temperature / humidity
sensor (no need for external add-on).
Flow rate 2.83 L / minute (0.1 CF /
minute).
Rechargeable battery provides up to 4
hours of continuous operation (charge
time 2 hours).
Buffer function allows storing and
redisplay of up to 500 measurement
data sets.
Controlled Environments
Indoor Air Quality
Hospitals & Clinics
Monitoring Growing Rooms
HVAC Applications
Filter Testing
Mining & Ore Processing
Emission Sourcing
Sample flow rate: 2.83L/min
Max. Particle concentration: 105,900
particles / L (coincidence loss max. 5%)
Buffer function: Store and recall values
for up to 500 measurements
PC interface: USB interface
SD storage device
TES ELECTRICAL ELECTRONIC CORP.
Features
QUALITY & RELIABILITY
7
TES-1150 / 1151 TES-1160 / 1161 TES-136
Sound Level Meter
TES-1150 / 1151 Digital Sound Level Meter
Features
IEC 61672-1
Class 2
0.1dB resolution
Range from 30 to 130dB
Maximum hold function
A, C, Z frequency weightings
A, C, Z peak hold function
Fast, Slow and Impulse Time
Weighting
AC/DC output jack
Back-screw for tripod fixture
Micro-USB (1151)
Auto data memory microSD
CARD 4GB (1151)
Digital Display4 digital LCD
Range30-90dB, 45-110dB, 65130dB
Resolution0.1dB
Typical Instrument Frequency
Range31.5Hz to 8KHz
Accuracy 1.0dB (ref
94dB@1KHz)
Dynamic Range65dB
Frequency WeightingA, C and Z
Time WeightingF (Fast), S (Slow)
and I (Impulse)
Thermo / Hygro / Barometer
TES-1160 / 1161 Thermo / Hygro / Barometer
Features
Chroma Meter
Triple LCD displays Barometric pressure,
Temperature, and Relative humidity.
Dew point and Wet bulb temperature reading.
Absolute humidity, Mixing ratio and Enthalpy
reading.
Water vapor pressure and Water saturation
pressure reading.
Pressure trend and tendency (P3h) reading.
Heat Index and Humidex reading.
MAX/MIN with Time Stamp.
Comparator function.
Alarm output function.
Auto power off function.
Data Hold function.
Manual data memory and read function.
Auto data logger function. (1161)
USB Interface. (1161)
Measurement Range
Humidity1% to 100%R.H.
Temperature-40~+100 (-40~+212)
Atmospheric pressure300 to 1200hPa
Resolution0.1%
Accuracy
R.H., 0.1, 0.1, 0.1hPa
Temperature 0.4 (at +5 to +60)
0.8 (at -20 to 5 and +60 to +80)
1.2 (at -40 to -20 and +80 to +100)
0.8 (at +41 to +140)
1.6 (at -4 to 41 and +140 to +176)
2.4 (at -40 to -4 and +176 to +212)
Humidity 3%RH (at 25, 20 to 80% RH)
4%RH (at 25, 10 to 20% RH and 80 to 90% RH).
5%RH (at 25, 0 to 10% RH and 90 to 100% RH).
Atmospheric pressure
2hPa at 25, 4hPa at -20 to 85
Response Time (at 1m/s air flow):
Humidity 63% <10s (from 33 to 75% RH)
Temperature 63% < 10s (from 15 to 45)
Sampling Rate1 sample/second.
Data Memory Capacity99 sets.
(Direct reading from LCD display)
Data Logger CapacitymicroSD Card 4GB (1161)
TES-136 Chroma Meter
Data logger function.
Auto power off function
USB Interface
TES ELECTRICAL ELECTRONIC CORP.
Applications:
8
Features
Triple Display, 4-digit LCD reading.
LED Color Bin select function (x, y) or
(Tcp, uv).
User calibration function.
User reference value setting function.
Data Hold function
Data memory and read function.
QUALITY & RELIABILITY
Measure tristimulus values,
chromaticity, color difference,
correlated color temperature, and
illuminance of light sources.
R&D and color inspection of light in
a variety of industries such as lamp
manufacturers, building and interior
design.
Set-up projectors for presentation
purposes.
Adjust color of CRTs, flat panel, and
other display devices.
Evaluate and control color of light
boxes and light booths.
Display : Triple display, 4 digit LCD
reading
Measuring Function :
Tristimulus values : XYZ
Chromaticity :
(Ev, x, y); (Ev, u, v); (Ev, d, Pe);
(Ev, d, Pc); (Ev, MAX, MIN).
Correlated color temperature:
(Ev, Tcp, uv); (Ev, Tcp, uv )
Color difference:
(X, Y, Z); (Ev, x, y);
(Ev, u, v); (Ev, uv);
(Ev, d,Pe); (Ev, d, Pc)
Range: 0.1 to 99990 lx, 0.01 to 9999 fc
(Chromaticity: 5 lx, 0.5 fcd or above)
Accuracy:
Ev (Linearity): 3%rdg 2dgts,
xy: 0.02 (800 lx, Standard Illuminant A measured)
Repeatability:
Ev: 0.5%rdg 1dgt, xy: 0.003
(800 lx, Standard Illuminant A measured)
Temperature Drift:
Ev: 5%rdg 2dgts, xy: 0.008
Humidity Drift:
Ev: 3%rdg 2dgts, xy: 0.005
Data Memory Capacity: 80 sets
Data Logger Capacity: micro SD Card 4GB
TES-137 TES-1358C TES-1358E
Luminance Meter
TES-137 Luminance Meter
Features
Dual Display, 4-digit LCD reading
Spectral Sensitivity close to CIE
photopic Curve.
Measuring Levels Ranging 0.001 to
1999k cd/m2, 0.001 to 580.0k fL.
Luminance ratio A/B, deviation %A,
different B-A and peak luminance
measurements
User calibration factor and colorcorrection functions
Accumulation luminance measurement
Max/Min/AVG function
Comparator function
Data Hold function
Data memory and read function
Data logger function
USB Interface
Applications:
Sound Analyzer
Luminance measurement of LCDs,
CRTs, LEDs, etc.
Luminance measurement of street
lighting, tunnel lighting, etc.
Measurement of airport lighting
facilities.
Transmittance measurement for LCD
polarizing plates and various filters.
Measurement of medical lighting.
Illuminance irregularities of automo-
bile license plates.
Luminance measurement of various
lighting facilities, etc.
Display: LCD display, 4 digit LCD reading
Range: 9.999, 99.99, 999.9, 9999, 99.99k,
999.9k, 1999k cd/m2
9.999, 99.99, 999.9, 9999, 99.99k, 580.0k fL
Auto ranging (6 step) (1 fL = 3.426 cd/m2)
Measuring Angle: 2 Overrange Display: Display showOL
Resolution: 0.001 cd/m2, 0.001 fL
Accuracy: 3% rdg 5dgt
(Calibrated to standard, incandescent
lamp, 2856 K , at 25/ 77)
Data Memory Capacity: 200 sets
Data Logger Capacity:
micro SD Card 4GB
Measuring Rate: Approx. 5 times/sec
TES-1358C Sound Analyzer
Features
For Delicate Sound Improvement
(Sound Effect/Sound
Environment)
Compliant with IEC 61672-1 class
2 standard
Real Time 1/1 (11 bands) & 1/3
(33 bands) octave analysis
Measurement can be started by
internal or external trigger.
Data transfer using USB
Dynamic range of 90dB
Real time clock with calendar
AC and DC output
Display: TFT-LCD color display
Range: 30dB to 130dB
Function: Lp, Leq, LE, Lmax, Lmin
Frequency: 12.5Hz to 20KHz
Frequency Weighting: A, C and Z
Time Weighting: Fast, Slow
1/1-1/3 Analyzer level range:
5 ranges in 10dB step, 40-130dB / 30120dB / 20-110dB / 10-100dB / 0-90dB
Memory Capacity: 10,000 data (Sound
level mode)
TES-1358E Sound Analyzer
For Delicate Sound Improvement
(Sound Effect/Sound
Environment)
Compliant with IEC 61672-1 class
1 standard
Real Time 1/1 (11 bands) & 1/3
(33 bands) octave analysis
Measurement can be started by
internal or external trigger.
Comparator output to trigger
external devices
Data transfer using USB
Dynamic range of 90dB
AC and DC output
Micro SD Card 4GB
Display: Super high-contrast
backlight TFT-LCD color display
Range: 30dB to 130dB
Function: Lp, Leq, LE, Lmax,
Lmin, L05, L10, L50, L90, L95
Frequency: 12.5Hz to 20KHz
Frequency Weighting: A, C and Z
Time Weighting: Fast, Slow,
=10ms, Impulse
Measurement level range: 5
ranges, 20-90dB / 20-100dB, 20110dB / 30-120dB / 40-130dB
Memory Capacity: Manual 250
data sets, Auto 250 blocks on
micro SD CARD 4GB
TES ELECTRICAL ELECTRONIC CORP.
Features
QUALITY & RELIABILITY
9
TES-3900 / 3901 TES-3910
Clamp Meter
TES-3900 / 3901 Clamp Meter (1000A)
uA measurement for HVAC flame sensors (3901)
mV measurement range to interface with other accessories (3901)
Data Hold, Auto hold & Peak hold mode
Max / Min record mode
DC Voltage :
Data memory & read function
Range Resolution
Accuracy
Sensitivity
(10 readings)
999.9mV 0.1mV
2.0mV
AC Current (50Hz to 400Hz) :
9.999V
1mV
1% 20 dgts 0.020V
Range Resolution
CAT 1000V
CAT 600V
Features
Motor Inrush Current measurement
Check 3 phase sequence
Variable-frequency drive (VFD) V &
Hz measurement.
Lo-Z voltage measurement to drain
ghost voltages.
Crest Factor & Harmonic ratio
measurement. (3901)
True RMS reading on AC and
DC+AC mode. (3901)
99.99A
10mA
999.9A
100mA
Accuracy
Sensitivity
2% 20dgts
0.10A
(50, 60Hz)
4% 20dgts
1.0A
(40 to 400Hz)
ACA Inrush Current :
Range Resolution Sensitivity Measurement Time
99.99A 0.01A
>5A
100mS
999.9A 0.1A
>50A
ATrms : (AC+DC) (Burden Voltage : 5mV/ A) (3901)
Range Resolution
Accuracy
Sensitivity
99.99A
10nA
0.20A
1% 20dgts
999.9A A100nA
2.0 A
AC Voltage (50Hz to 400Hz) :
Range Resolution
Accuracy
Sensitivity
999.9mV 0.1mV 1% 20 dgts 2.0mV
9.999V
1mV
0.020V
(50, 60Hz)
99.99V
10mV 2% 20 dgts 0.20V
600.0V
100mV (40 to 400Hz)
2V
99.99V
600.0V
10mV
100mV
0.20V
2V
on the 999.9
range) :
Resistance (Continuity<40
Range Resolution
Accuracy
Overload
Protection
999.9 100m 9.999K
1
1% 10 dgts 1000V
99.99K 10 999.9K 100 3
Phase sequence indication :
Range
Frequency Response Overload Protection
80V to 480V
50Hz / 60Hz
1000V
Diode (Continuity<40mV) :
Range Resolution Accuracy Overload Protection
3.000V
1mV 2% 1dgt
1000V
Frequency :
Range Resolution Accuracy Sensitivity
0.5%rdg ACV>1.2V,
40Hz/1KHz 0.1Hz
2dgts
ACA>6A
TES-3910 Trms Clamp Meter (DC/AC 1000A)
Data hold, Auto hold & Peak hold mode.
Max/Min/Avg record mode.
Data memory & read function.
VFD Trms
AC Current (40Hz to 400Hz)
Range Resolution
Accuracy
Sensitivity
2% 20dgts
99.99A
10mA
0.25A
(50, 60Hz)
4% 20dgts
999.9A 100mA
2.5A
(40 to 400Hz)
Overload Protection1000A
DC Current :
TES ELECTRICAL ELECTRONIC CORP.
CAT 1000V
CAT 600V
Features
Variable-frequency drive (VFD) V & Hz
measurement.
Lo-Z voltage measurement to drain ghost
voltages.
Check 3 phase sequence.
True RMS reading on AC and DC+AC
mode.
Inrush current measurement.
A measurement for HVAC flame sensors.
mV measurement range to interface with
other accessories.
Crest Factor & Harmonic ratio
measurement.
10 QUALITY & RELIABILITY
Range Resolution
Accuracy Sensitivity
99.99A
10mA
0.25A
2% 20dgts
999.9A
100mA
2.5A
Overload Protection1000A
VFD Trms
ACA Inrush Current
Range Resolution Sensitivity Measurement Time
99.99A 0.01A
>5A
100mS
999.9A 0.1A
>50A
Overload Protection1000AAC
(Burden Voltage : 3.6mV/ A)
DC A
Range Resolution
Accuracy
Sensitivity
99.99A
10nA
0.30 A
1% 20dgts
999.9A A100nA
3.0 A
Overload Protection1000AAC
VFD Trms (Burden Voltage : 3.6mV/ A)
AC A
Range Resolution
Accuracy
Sensitivity
99.99A
10nA
1% 10dgts (50, 60Hz) 0.30 A
999.9A 100nA 2% 10dgts (40~400Hz) 3.0 A
Overload Protection1000AAC
VFD Trms
AC Voltage (40Hz to 400Hz)
Range Resolution
Accuracy
Sensitivity
1% 10dgts
(50, 60Hz)
2% 10dgts
(40~400Hz)
40~300Hz on mV
range >2mV
2mV
20mV
200mV
Resistance (Continuity<40 on the
Range Resolution
Accuracy
999.9 100m 9.999K
1
1% 10 dgts
99.99K 10 999.9K 100 range) :
Overload
Protection
999.9mV
9.999V
99.99V
0.1mV
1mV
10mV
999.9V
100mV
2V
Overload Protection1000V
DC Voltage :
Range Resolution
Accuracy
Sensitivity
999.9mV 0.1mV
2mV
9.999V
1mV
1% 20 dgts 20mV
99.99V
10mV
200mV
999.9V
100mV
2V
1000V
3
Phase sequence indication :
Range
Frequency Response Overload Protection
80V to 480V
50Hz / 60Hz
1000V
Diode (Continuity<40mV) :
Range Resolution Accuracy Overload Protection
3.000V
1mV 1% 10dgt
1000V
Frequency :
Range Resolution Accuracy Sensitivity
0.5%rdg V > 5% range
40Hz/1KHz 0.1Hz
2dgts A, A > 30%
TES-2900 TES-2950
Multimeter
TES-2900 True RMS Multimeter
Relative value display.
3 phase Rotation Measurement
Data hold & Auto hold mode.
Max/Min/Avg record mode.
Frequency count. (Auto-Range)
Data memory & read function.
Specifications:
AC conversions are ac-coupled and valid from 3 % to 100 % of range.
999.9mV / 9.999V / 99.99V / 999.9V / VFD
AC Voltage
999.9mV / 9.999V / 99.99V / 999.9V
DC Voltage
999.9 /9.999k /99.99k /999.9k /9.999M /50M
Resistance
99.99nS
Conductance
K Type- 40 ~ 1372 (- 40 ~ 2502)
Temperature
J Type- 40 ~ 1200 (- 40 ~ 2192)
999.9uA / 9999uA / 99.99mA / 400.0mA / 9.999A
AC Current
999.9uA / 9999uA / 99.99mA / 400.0mA / 9.999A
DC Current
10.00nF/ 100.0nF/ 1.000uF/ 10.00uF/ 100.0uF/ 9999uF
Capacitance
2V
Diode
Phase sequence indication
80V ~ 480V
3
99.99Hz / 999.9Hz / 9.999kHz / 99.99kHz / 999.9kHz / 9999kHz
Frequency
CAT 1000V
CAT 600V
Features
10,000 Count True RMS reading
Capacitance check (10nF ~ 10,
000uF)
Temperature check (-40~1372, K
type)
Variable Frequency drive (VFD) V &
Hz measurement.
Lo-Z voltage measurement to drain
ghost voltages.
TES-2950 LCR Trms Multimeter
Features
Variable Frequency drive (VFD) V & Hz measurement.
Inductance (4mH ~ 40H) & Capacitance (4nF ~ 40uF) measurement
20MHz TTL logic check
Frequency Check (4kHz ~ 4000kHz, Auto-ranging)
Relative value display
Temperature type K, J measurement (-40~200)
Data hold, Auto hold & Peak hold mode.
Max/Min/Avg record mode.
Specifications:
400mV/ 4V/ 40V/ 400V/ 1000V
Voltage (Trms)
400mV/ 4V/ 40V / 400V/ 1000V
DC Voltage
400uA/ 4mA/ 40mA/ 400mA/ 10A
AC Current (Trms)
400uA/ 4mA/ 40mA/ 400mA/ 10A
DC Current
400 / 4k/ 40k/ 400k/ 4M / 40M Resistance
4kHz / 40KHz / 400kHz / 4000kHz
Frequency
4nF/ 40nF/ 400nF/ 4uF/ 40uF
Capacitance
4mH/ 40mH/ 400mH/ 4H/ 40H
Inductance (H)
K Type
-40 ~ 200 (-40 ~ 392)
Temperature
-40 ~ 200 (-40 ~ 392)
J Type
AC
CAT 1000V
CAT 600V
Overload Protection
1000V
Continuity( ) :
Range Operation Resistance Overload Protection
Continuous audible tone for
1000V
test resistance below 30 TES ELECTRICAL ELECTRONIC CORP.
Diode :
Range Resolution Accuracy
1mV
2% 1
QUALITY & RELIABILITY
11
PROVA1660 TES-135A TES-133
Transformer Turns Ratio Meter
Prova 1660 Transformer Turns Ratio Meter
CAT 50V
Features
Measurements of 1 and 3 Transformer/VT/CT Turns Ratio.
VT/PT ratio 0.8~10000,
CT ratio 0.8~2000.
Ten Test Frequencies (50~400Hz).
Color Meter
Graphical and Literal Illustration of
Measurements and Connections with
Large Back-lighted Dot Matrix 240 x 128
LCD. Display Test Data with Nameplate
Transformer Values for Easy
Interpretation.
Display Turns Ratio, Deviation, Secondary Output, Excitation Voltage and
Current, Phase Angle and Nameplate
Transformer/VT/CT Values in one page
for easy transformer quality
interpretation.
Check for Live Test Points, Short
Circuit, Open Circuit, and Reverse
Polarity before Each Measurement.
Message is displayed to Warn Users
(But, checking is not performed once
measurement starts).
Store 4096 Files of Transformer
Nameplate Values (VT/PT/CT,1 / 3,
Test Frequency, Primary and Secondary Voltages or Ratio, RCF) and
Measuring Data.
9 types of 3 Windings Connections
pre-installed for easy user selection.
TES-135A Color Meter
Features
Check color difference between
two samples
Color difference displayed in
(L*, a*, b*), (E*ab, C*ab,
H*ab),(Y, x, y), (X, Y, Z) or
(Rs, Gs, Bs)
Color space displayed in (L*, a*,
b*), (L*, C*ab, hab), (Y, x, y),
(X, Y, Z) or (Rs, Gs, Bs).
MAX, MIN & AVG functions
Software with Mini-USB cable
Tolerance function
Auto Memory (99 sets) & Read
function
TES ELECTRICAL ELECTRONIC CORP.
Luminous Flux Meter
12 QUALITY & RELIABILITY
Wireless Blue Tooth Communication with PC.
Select Filter to Remove Field
Noise (Slow, Normal, Fast).
Disable or Enable AutoPower-Off with Programmable
Time.
Built-in calendar clock.
Records with Date and Time
Stamp.
Powerful Lithium Battery
(3400mAH) with built-in
Charging Circuit.
User Programmable RCF
(Reference Correction Factor,
0.99~1.01) to Correct
Accuracy within 1% Error.
Friendly File System for Easy
On-site Data Retrieval and
Nameplate Values
Management.
PC Application Software
included.
Display: Triple 4 digit LCD display
Illuminating / Viewing geometry:
45 /0 - 1 illumination at 45 ,
measurement at 0 Measuring area: Approx. 2mm
Target color memory: 8 channel;
set by measurement or keypad
Measuring range: L*: 10 to 100
Measurement conditions: Observe:
CIE 2 Standard Observer.
Illuminant: White LED lamp.
Repeatability: Standard deviation
within E*ab 0.5
Auto data Memory & Read: 99 sets
Auto Power off: Approx. 3 minutes
TES-133 Luminous Flux Meter
Ideal for:
LEDs, Optical Fiber lamps, Small
lamps
Features
Measuring range : 0.05 ~ 7000
lumens
Comparator function
RS-232 Interface / Software
Data Memory : 999 sets (Direct
reading from LCD display)
Data Logging function : 40,000
sets
Display: 4 digit LCD read out
Range: 9.999, 99.99, 999.9, 7000
lumens. Auto ranging (4 Steps)
Resolution: 0.001 lumens
Accuracy: 0.05 ~ 0.1 - 7%,
0.1 ~ 1000 - 1%, 1000 to 7000 - 3%
Integrating Sphere:
Diameter: 50mm
Sample pore: 12.7mm diameter
1: 6%
CIE photopic f
Temperature Characteristics:
0.1%/
Data Memory Capacity: 999 sets
Data Logger Capacity: 40,000 sets
PROVA200A / 200A-24 / 210 / 218 PROVA1011
PV Analyzer
Prova 200A / 200A-24 / 210 / 218 PV Analyzer
(Photovoltaic I-V Curve Tester)
Max. solar panel power (Pmax)
CAT Features
Prova 200A, 210, 218: I-V curve test
for solar panel/module
Prova 200A-24: I-V curve test for
solar cell/panel
search by auto-scan:
Prova 200A: 60V, 6A
Prova 200A-24:24V, 600mA
Prova 210: 60V, 12A
Prova 218: 85V, 8.5A (500W capability)
Best Resolution:
Prova 200A: 1mV, .01mA
Prova 200A-24: 1mV, 10 A
Prova 210, 218: 1mV, 1mA
Manual single point I-V test
Max. voltage (Vmaxp) at Pmax
Max. current (Imaxp) at Pmax
Voltage at open circuit (Vopen)
Current at short circuit (Ishort)
I-V Curve with cursor to display
each data point
Efficiency (%) calculation of solar
panel
Solar panel area setting: 0.001m2
~ 9999m2
Standard light source setting:
10W/ m2 ~ 1000W/ m2
Communicate with PC with USB
cable
Min. power setting for alarm
function
Built-in calendar clock
Built-in battery charging circuit
Rechargeable lithium batteries
and AC adaptor
Memory Size: 100 records
Prova 210, 218: Sampling time
of data logging: 0 ~ 99 min.
Large LCD with backlight
Application:
Quality Control in the production
line, warehouse, or site of
installation
Identify the solar power system
requirement
Maintenance of solar panels
Verify the best installation angle
of solar panels
Prova 1011 PV System Analyzer
Voltage at open circuit (Voc);
CAT 1000V
CAT 300V
Features
I-V curve test for solar system
Max. solar system power (Pmax)
Data logging with built-in calendar
clock
Optical USB cable for PC
Rechargeable Lithium battery, low
battery warning, AC power adaptor
DC Voltage Measurement
Range
Resolution
Accuracy
1% (1% of
1 ~ 1000V 0.01V/0.1V/1V
Voc 0.1V)
Voc: Open circuit voltage of solar system
DC Current Measurement
Range
Resolution
Accuracy
1% (1% of
0.1 ~ 12A 1mA / 10mA
Isc 0.1V)
Isc: Short circuit current of solar system
DC Current Simulation
Range
Resolution
0.1~ 12A 1mA / 10mA
Accuracy
1% 9mA
Irradiance Measurement
Range
ResolutionAccuracy
Accuracy
Range
Resolution
0~2000W/m2
1W/m2 3% 20dgts
Temperature Measurement
Range
Resolution
Accuracy
-20~85
0.1
1% 1
Optional power clamps:
SOLAR 15 DC Current Probe
SOLAR 21 AC Power Clamp
TES ELECTRICAL ELECTRONIC CORP.
search by auto-scan: 1000V, 12A
(12000W capability)
The analyzer and the Remote Solar
Detector are connected by Bluetooth
wireless communication (Bluetooth
2.1 + EDR Class 1).
Intelligent test logic with no personnel
attendance required in the field. Solar
system analyzer waits and tests the
system until appropriate sunlight
irradiance is detected
Max. Voltage (Vpm) at Pmax; Max.
Current (Ipm) at Pmax.
Current at short circuit (Isc).
Efficiency (%) calculation of solar
panels with Parameters entry
Temperature measurement of solar
panel
Irradiance measurement of sun
light.
Series resistance (Rs) calculation of
solar panels
I-V curve with cursor to display each
data point.
With data logging/open function, the
I-V curves of solar system can be
analyzed / recorded for a period of
time (e.g. 60 min.).
Conversion of I-V curve under OPC
to data under standard test condition (STC) based upon IEC standard
Provide Operation Condition (OPC)
and Standard Test Condition (STC)
test reports for verification of solar
panel performance (OK or NO OK)
With optional power clamps
(SOLAR 15 and SOLAR 21),
measure/record DC power output of
solar system and AC power output
of inverter (1 phase or balanced 3
phase); calculate efficiency of DC to
AC power conversion and max.
output power
QUALITY & RELIABILITY
13
TES-132 TES-1333 / 1333R TES-SS1
Solar Power Meter
TES-132 Solar Power Meter (Data logging)
Features
Wide spectral range.
Excellent long term stability.
Cosine corrected.
Automatic transmission measurements.
Select either power or transmission.
Solar energy measurement.
User calibration factor setting function.
Select either W/m2 or Btu / (ft2 x h) units.
Data Hold/MAX/MIN/AVG modes.
Auto Data Memory function.
(microSD CARD 2GB)
Data Memory and Read function.
(99 sets)
Software and USB interface to PC.
Applications
Meteorology.
Agriculture.
Solar radiation measurement.
Solar power research.
Physics and optical laboratories.
Solar transmission measurement.
Identify high performance
windows.
Display: LCD display, 4 digit LCD reading
Range: 200.0 W/m2 , 2000 W/m2
63.4 Btu / (ft2 x h),
634 Btu / (ft2 x h)
Resolution: 0.1W / m2 , 1W/m2
0.1Btu / (ft2 x h), 1Btu / (ft2 x h)
Spectral response: 400 to 1000nm
Accuracy: Typically within 10 W/m2
[ 3 Btu / (ft 2 x h)] or 5%,
whichever is greater in sunlight;
Additional temperature induced
error 0.38 W/m 2/ [ 0.12
Btu / (ft2 x h)/] from 25
Angular accuracy:
Cosine corrected <5% for angles < 60 Drift: < 2% per year
Calibration: User recalibration available
Over-Input: Display shows OL
Sampling Rate: 1 times/sec
Manual Data Memory and Read: 99 sets
Auto Data Memory: MicroSD CARD 2GB
TES-1333 / TES-1333R Solar Power Meter
Features
Wide spectral range
Excellent long term stability
Cosine corrected
Automatic transmission measurements
Select either power or transmission
Solar energy measurement
Current time setting function
User calibration factor setting
function
End-mount light sensor
Select either W/m2 or Btu/(ft2 x h)
units
Data Hold / MAX / MIN / AVE modes
Data Memory and Read function (99
sets)
Auto Data Memory and RS232
interface to PC (TES-1333R)
Applications
Meteorology
Agriculture
Solar radiation measurement
Solar power research
Physics and optical laboratories
Solar transmission measurement
Identify high performance
windows
TES-SS1 Solar Power Development System
TES ELECTRICAL ELECTRONIC CORP.
Includes
14 QUALITY & RELIABILITY
Prova 200A PV Analyzer
Prova 800 Multi-Input Thermometer /
Datalogger
Prova 8300 Light Radiation Controller
Features
1.Control halogen lamp (or other
light source) to emulate sunlight
irradiance
2.Low cost for educational purpose
3.Standard pyranometer (sunlight
sensor) to show true irradiance
4.User Friendly Interface
Solar Cell / Module Table
Specifications
1.Dimension: 300 (L) x 300 (W) x
420 (H) mm / 11.8x 11.8x 16.5
2.Height from Halogen Lamps to
table base:
* Adjustable from 90mm to 30cm
* Standard: 150mm
3.Solar Cell / Module for
measurement: max. 300 x
250mm / 11.8x 9.8
4.Light sensor: 0 ~ 1500W/m2
5.with K-type Thermocouple
6.with Halogen Lamp (Simulation
of Sun Light): DC 12V, 50W x 3 pcs
7.Input Voltage (for Halogen
Lamps): DC 0V ~ 40V
Prova 800 / 830 TES-1384
Multi-input Thermometer / Datalogger
Prova 800 Multi-input Thermometer / Datalogger
Prova 830 Portable Paperless recorder
Features
Both models can work as Multi-
input thermometer or Paperless
Recorder
Prova 830: 5.7Color TFT LCD
(320 x 240) with backlight
Prova 800: 4.5STN LCD (240 x
128) with backlight
Prova 830: Color graphic display
of 8 curves at the same time
Prova 800: Graphic display of
overall trend for each input
8 input temperature measurement/logging (/)
Selection of 11 types of thermocouple
Easy socket for thermocouple
mini connector
Basic accuracy 0.1% 1 (K
type)
Programmable Hi-Lo alarm with
timers when out of HI-LO limits
Display of max and min values for
each input
Sampling Rate 8 Inputs / 1
second
Prova 830: 28 Hours Recording
with Lithium Battery of 3400mAH
Prova 800: 24 Hours Recording
with Alkaline Batteries of
2400mAH
Standard 2G SD memory card
(store 3.8-year of data)
SD card directly read by PC
Easy data file management (Read
and Delete functions)
Built-in calendar clock
Accept Analog Outputs from
instruments
Screen hardcopy for easy
documentation
Isolated Input Protection of
350Vp-p between any two inputs
Ready to use package
(Thermocouples, SD card and
Battery)
Independent Input Setup (type of
thermocouple, Hi-Lo alarm
values, name of Engineering Unit)
Programmable Engineering Unit
(E.U.) to integrate Analog Output
(-60 to 60 mV) from instruments
(e.g. Sound level meter, Humidity
meter, Current adaptor)
Prova 830: Digital and analog
(bar graph) data display
Prova 800: Hide or display
selected curves
Application:
PC, Semiconductor, Automotive, Airconditioning, Freezer, Metallurgy,
Petroleum, Chemical, Construction
materials, Papermaking, Food,
Pharmacy, Agriculture, Flower
planting, Thermal treatment, Water
treatment
TES-1384 4 Channels Thermometer / Datalogger
Features
Isolated Input Protection of
Independent Input Setup (type of
thermocouple, Hi-Lo alarm
values)
Data Memory and Read function
(99 sets)
Datalogging Capacity (512 KB)
Software with USB cable
TES ELECTRICAL ELECTRONIC CORP.
350Vp-p between any two inputs
0.05% Accuracy.
K, J, E, T, R, S, N, L, U, B, C
Thermocouple Input
Display T1, T2, T3 & T4 Simultaneously
Programmable Hi-Lo alarm for 4
inputs
MAX, MIN, Max-Min & AVG
values
QUALITY & RELIABILITY
15
AVM-01 / 03 AVM-05 / 07 AVM-301 / 303 / 305
Anemometer
AVM-01/03 Anemometer
Features
Sensitive for low/high air velocity
Ergonomic Design
Detachable 52mm (diameter)
Vane Head
Anemometer Comparison
Model
Air
Air
Velocity
Temperature
AVM-01
AVM-03
Range: ( 3%rdg 0.3)
M/S: 0.0~45.0 (Meter/per Sec.)
KNOTS: 0.0~88.0
Ft/min: 0~8800
Km/hr: 0.0~140.0
Temperature (AVM-03): 0~60
(32~140)
Air
Flow
AVM-05
AVM-07
AVM-301
AVM-303
AVM-305
Working
with PC
Memory
(Datalogging)
AVM-05/07 Flow Anemometer
Features
Flow (CFM, CMM)
Instant/Ave/2/3 Vmax Flow
Measurement
Velocity m/s, ft/min, knots, km/hr,
mph
Memory of 2000 Records
RS-232C (AVM-07)
Hold / Max / Min Function
Range: ( 3%rdg 0.3)
M/S: 0.0~45.0 (Meter/per Sec.)
KNOTS: 0.0~88.0
Ft/min: 0~8800
Km/hr: 0.0~140.0
Mph: 0.0~100.0
Wind Temperature :
0~45 (32~113)
( 1.0/ 1.8)
Operation Temperature:0~50
Display: 3 1/2 Digits Dual Display
LCD
AVM-301 / 303 / 305 Anemometer
Ideal for
TES ELECTRICAL ELECTRONIC CORP.
16 QUALITY & RELIABILITY
Ventilation survey
Air-conditioning / Heating
Sports recreational
Features
Lower Power Consumption (6mA)
Max/Min/Ave and Data hold
function
RS-232C interface (AVM-303/305
only)
Sensitive for low air velocity
Ergonomic Design
Detachable 52mm (diameter)
Vane Head
Optional portable thermal printer
(AVM-303/305 only)
Air Temperature Measurement
(AVM-305 only)
1.8 meters coiled cable/back
mounting screw for long
extension
Units
M/s
ft/min
knots
Km/hr
mph
Range
0.0~45.0
0~8800
0.0~88.00
0.0~160.0
0.0~100.0
Resolution
0.01
0.01/0.1/1
0.01/0.1
0.01/0.1
0.01/0.1
Threshold
0.5
60
0.6
1.0
0.7
Accuracy
3% 0.3
3% 40
3% 0.4
3% 0.8
3% 0.4
TES-1340 / 1341 TES-32 TES-33
Hot-Wire Anemometer
TES-1340 / 1341 Hot-Wire Anemometer
Features
Air Velocity / Air Volume (CFM /
CMM)
Instant / Avg / 2/3 Vmax Flow
Measurement
Velocity m/s, ft/min, knots, km/hr,
mph
Data hold & Max/Min with time
stamp
Air Flow
Air Flow Volume
Temperature
Humidity
Fast Response / Telescopic Probe
Manual Data Memory and Read
function (99 sets)
Stand-alone Datalogging Capacity
20,000 sets (TES-1341)
Relative Humidity Measurement,
DEW point & Wet bulb function
(TES-1341)
Software via USB cable (TES-1341)
Measuring Range
0.1 to 30.0 m/s
0.2 to 110 km/hr
10 to 6000 ft/min
0.1 to 59 knots
0.12 to 68 MPH
0 to 999900 CFM
0 to 999900 CMM
-20 ~ +60
-4 ~ +140
0 to 100%RH
Resolution
0.01 m/s
0.1 km/hr
1 ft/min
0.01 knots
0.01 MPH
0.001 CFM
0.001 CMM
Accuracy
3% of reading
1%FS
0.1, 0.1
0.5, 0.9
0.1% RH
3%RH
Battery Tester
TES-32 Battery Capacrty Tester
Features
Right Device to know the "True
Life"of your battery capacity.
(Resistive/Voltage)
On-line testing without shutting
down battery
Built in Comparator
RS-232 Interface & Software
Datalogging function
Battery Types Tested:
Compact storage battery, Alkali
and lead-acid batteries.
Frequency: 1KHz
Accuracy: 10%
40m , 400m , 4, 40
10,100, 1m ,
Resolution
10m Accuracy
(1% + 8dgt)
Range
V
4V, 40V
1mV, 10mV
(0.1% + 6dgt)
TES-33 Battery Capacity Tester
Features
Down Battery
Simultaneously Measure Battery
Resistance, Voltage, Current
&Temperature
Auto-hold and Auto-data storage
Rates Conditions as Pass,
Warning, or Fail
Memory and Read function
Datalogging function
Compact and Light weight
Manual Data Memory: 999 sets
Continuous Data Memory: 6000
sets
RS-232 Interface / Software
Battery Types Tested:
Compact storage batteries,
Alkaline and lead-acid batteries
Resistance:
4m, 40m, 400m, 4,
40, 400
Measurement Condition:
Current: Approx. 40mA, 4mA,
400 A,40 A, 4 A
Frequency: 1KHz 30Hz
DC Voltage: 6V, 60V
Temperature:
-20 ~ 60 (-4 ~ 140)
DC Current: 600A
Open Circuit Voltage: 5V max
TES ELECTRICAL ELECTRONIC CORP.
Test Condition Without Shutting
QUALITY & RELIABILITY
17
Prova iCal Prova 100
Calibrator
Prova iCal Documenting Multifunction Calibrator
Short circuit protection for
Features
Unique mapping function let you
calibrate temperature (300) or
voltage (220V) directly (instead of 4
to 20mA indirectly)
iCal is a multifunction calibrator
and an arbitrary function generator.
Source: mA (4 to 20mA), V (0 to
15V, 0 to 70mV), Hz, sine wave,
square wave, triangular wave,
truncated sine wave, user programmable waveform and temperature for
11 types of thermocouples.
Measure: Current (mA), Voltage (V,
mV) and temperature in or .
Programmable cold junction
compensation allows users to fine
tune temperature output and
measurement.
Programmable 0% and 100% value
for easy 25% step function.
Output error warning when output is
shorted or open.
voltage output.
Clear and easy user interface
(Numerical key pad, sliding switch
and dot matrix LCM with
backlight).
Voltage, frequency, PWM dutycycle (square wave and triangular
wave), and offset are programmable in the Hz function.
Frequency range (0.3Hz to 20
KHz) covers application of audio
band (speaker, MP3, MD etc.)
DTMF (Dual Tone MultiFrequency) can perform professional testing for telephone line
and audio product (MP3 or MD).
Auto-step and auto-ramp
functions can quickly perform
linear test.
PC can program calibrator
through USB port.
iCal can perform data logging
with programmable sampling time
(0-255 seconds) and memory of
4000 records.
Rechargeable Lithium battery
(1600mAH) with built-in charging
circuit.
Calibration results (source and
measure) can be saved in
memory (2000 records). Then
users download them to a PC for
documentation. No needs to
transcribe calibration data
manually.
To distinguish calibration data
at different locations, data can be
saved under different file names.
Applications:
Calibration of 4 to 20mA
transmitters and panel meters.
Temperature calibration of
panel meters or instruments for
11 types of thermocouples.
Calibration of valve opening
by changing duty cycle of a
PWM signal.
Generation of selected test
frequency and waveform for
electronic device.
Pre-stored 1/3 octave audition,
white noise, and pink noise for
MP3, MD, speaker and audio
driver tests.
Audio Frequency Synthesizer:
Programmable frequency and
phase synthesis of single tone,
DTMF(Double Tone, MultiFrequency) for audio products
such as MP3, MD and telephone line.
Function generation for
transistor DC bias characteristics test, amplifier overload and
transient characteristics.
Function generation for
vibration testing.
Calibration of a chart recorder
with different waveforms (sine,
square, or triangular wave).
Prova 100 4-20 mA Loop Calibrator
TES ELECTRICAL ELECTRONIC CORP.
Features
18 QUALITY & RELIABILITY
4-20 mA (1k load, 24V Loop Supply)
0-24V output
Easy Key-pad Operation
Auto Step and Auto Ramp Functions
0-20mA, 0-24mA selectable
0-100% Input, step up and down
Beeper Warning when Output is Open
Range
Resolution
Accuracy
0-4mA
1 A
0.025% + 10 A
4-24mA
1 A
0.025% + 5 A
Beeper warning when output is open and
specified output > 1mA
Range
Resolution
Accuracy
0-4V
1mV
0.05% + 10mV
4-24V
1mV
0.05% + 5mV
Beeper warning when output is short and
specified output > 100mV
Prova 123 Prova 125 TES-1356
Prova 123 Multifunction Calibrator
Features
4-20mA (1K load, 24V
Loop Supply)
0~100.00mV, 0~1.0000V,
0~10.000V
K.J.E.T. Thermocouples
mA DC Current (1k Max, Load, 24V Loop Supply)
Range
Resolution
Accuracy
0~24mA
1A
0.025% 3A
Beeper warning when output is open and specified utput >1mA
mV, V DC Voltage (1mA Supply Current)
Range
Resolution
Accuracy
0~100.00mV
10 V
0.05% 30 V
0~10.000V
1mV
0.05% 3mV
0~1.0000V
100 V 0.05% 300 V
Beeper warning when output is short and specified output >10mV
( & )
Frequency 1~62,500 Hz
0.025% Basic Accuracy
Easy Key-pad Operation
Easy Step & Auto Ramp
K, J, E, T Type (1, 1 Resolution, 1kload Min.)
Functions
Range
Typical Accuracy
0~20mA, 0~24mA selectK: -200~1370/-328~2400 0.8/ 1.5
able
J: -100~760/-148~1400 0.7/ 1.2
0~100% Input (mA, mV, V) E: -100~700/-148~1292 0.7/ 1.2
T: -200~400/-328~752
0.8/ 1.5
Beeper warning when
output is open (mA) or
short (mV, V)
Prova 125 Temperature Calibrator
Features
11 Types of Thermo-
couples
(K, J, E, T, R, S, N, L, U,
B, C)
, and mV outputs
0.1, 0.1 Resolution
T function, Easy
INCREMENT& DECREMENT
Ideal for: R&D Laboratory,
Production Line and
Service & Calibration
Display: 4+5 Digits
Range
K: -200~1,370/-328~2,498
J: -200~1,050/-328~1,922
E: -150~800/-238~1,472
T: -200~400/-328~752
R: 0~1,760/32~3,200
S: 0~1,760/32~3,200
N: -200~1,300/-328~2,372
L: -200~900/-328~1,652
U: 0~600/32~1,112
B: 600~1,820/1,112~3,308
C: 0~2,310/32~4,190
Typical Accuracy
0.4/ 0.7
0.4/ 0.7
0.4/ 0.7
0.4/ 0.7
0.5/ 0.9
0.5/ 1.0
0.4/ 0.7
0.4/ 0.7
0.4/ 0.7
0.5/ 0.9
0.4/ 0.8
TES-1356 Sound Level Calibrator
Features
94dB and 114dB Sound
IEC 942 1988 Class2
Output sound-pressure levels:
114dB and 94dB re 20 uPa under
reference conditions
Output frequency: 1000Hz 4%
Reference condition:
Temperature 20 (68)
Atmospheric Pressure:
1013mbar (760mm par Hg)
Relative humidity: 65%
Accuracy: 0.5dB
TES ELECTRICAL ELECTRONIC CORP.
Calibration at 1KHz
Fits 1", 1/2" or 1/4" diameter
microphone
Conforms to ANSI S1.40-1984
and IEC942-1988 Class 2.
QUALITY & RELIABILITY
19
TES-1500 TES-1370 TES-1372 / 1372R
Capacit ance Meter
TES-1500 Capacitance Meter
Features
0.5% Accuracy
Overload Fuse protection
Test Clips/Direct insert jack for
easy measure
Range:200pF/2nF/20nF/200nF/
2F/20F/200F/2000F/20mF
Measurement Voltage: 4.5V
max.
Test frequency: 8/80/800 Hz
Principle: Dual Slop Integration
Zero Aro Adjustment: 20pF
Approx.
CO / CO2 Analyzer
TES-1370 CO2 Analyzer
Features
Data Memory and Read function
Continuous or manual data
logging and reading
Data hold & Max/Min with Time
stamp
Alarm & Time setting
Maintenance free dual wave-
length NDIR infrared CO2 sensor
(non-dispersive infrared)
Measuring Range:
CO2: 0~6,000 ppm
Temp.: -20~ 60 / -4 ~ 140
Humidity: 10% ~ 95%RH
Resolution:
1ppm, 0.1/0.1, 0.1%RH
Accuracy:
CO2: 3% of reading or
50ppm,which is greater
Temp.: 0.5 / 0.9
Humidity:
3%RH (at 25, 30 ~95%RH)
5%RH (at 25, 10 ~ 30%RH)
Manual Data Memory Capacity:
99 sets
Auto Memory Capacity:
20,000 sets
TES-1370A (220V),
TES-1370B(110V)
TES-1372 / 1372R CO Analyzer
Features
TES ELECTRICAL ELECTRONIC CORP.
CO Range: 0 ~ 999 ppm (CO)
Max Hold with Time Stamp /
20 QUALITY & RELIABILITY
STEL,TWA
Alarm level Setting
Replaceable Sensor extends
meter life
Stabilized electrochemical CO
Auto Datalogger (10,000 sets)
sensor
Automatic sensor zeroing upon
start-up
Auto Power-off time setting
Typical three year sensor life, one
year calibration cycle
Manual Data memory (999 sets)
(1372R)
Range: 0 ~ 999 ppm
Resolution: 1 ppm
Accuracy: 5% of reading or
2ppm, which is greater
Sensor Type / Life: Stabilized
electrochemical Gas-specific / 3
years
Manual Data Memory Capacity:
999 sets (Direct reading from
LCD display)
Auto Data Memory Capacity:
10,000 sets (Only downloaded by
PC) (1372R)
TES-1380 TES-1381 CM-01
Conductivity & pH / ORP Meter
TES-1380 pH/ORP/Temp. Meter (RS-232)
Features
Fast and easy pH measurement
Dual LCD display shows pH/ &
Single record 99 point,
or mV/& simultaneously
continuous record 99 point MAX
4500 data
Auto-Data-Hold function
RS-232 Interface & Software
TES-1380K for complete kits
(with BS4, BS7, PH-200 and
PT-100, Ipc/each)
Range:
pH: 0~14 pH mV: 0~1999mV
Temp.: 0~100 (32~200)
Resolution:
pH: 0.001pH mV: 0.1mV
Temp. (): 0.1
Temp. (): 0.1
Accuracy:
pH: 0.002pH mV: 0.2mV
Temp. (): 0.5, Temp. (): 0.9
Optional:
pH electrode, Temperature probe &
Buffer solution
Conductivity & pH/ORP Meter
TES-1381 Conductivity & pH/ORP Meter
Features
0.001pH High Resolution
pH, mV, Conductivity, TDS,
Resistance, Salinity, Concentration &
Temperature Measurement
Programmable Temperature Coefficient for conductivity measurement
Practical Salinity in the Range of 0 ~
42.0, in accordance with UNESCO
data measurement
Concentration mode, the operator can
create a user-defined table.
99 sets data memory and read function
512KB auto datalogging capacity
USB Interface
Display: 41/2 digital LCD display
Resolution: pH: 0.001pH, mV: 0.1mV,
Temp.: 0.1/0.1, Conductivity: 0.01
S/cm, TDS: 0.01mg/L, Resistivity: 0.
001 M cm, Salinity: 0.1
Measurement Range:
pH: 0 ~ 14pH, mV: 0 ~ 2000mV
Temp.: 0~100 (32 ~ 212)
Conductivity: 0~ 19.99S/199.9S/
1999S/19.99mS/199mS/cm
TDS: 0~13.20mg/L, 132.0mg/L, 1320mg/L,
13.2g/L, 132g/L
Resistivity: 0~ 1.999M cm,
0~19.99M cm
Salinity: 0.0 to 42.0 S (ppt)
Concentration: 0 to 9999
Accuracy:
pH: 0.01pH
mV: (0.1%+1d)
Temp.: 0.5(0.9)
Conductivity / TDS / Resistivity / Salinity: 0.3% reading
Optional Accessories:
PT100: RTD Temp. probe
pH-200: pH Electrode
CS150: Conductivity probe (K=1.0)
BS4: pH4 buffer solution
BS7: pH7 buffer solution
D C / AC Current Clamp
CM-01 DC/AC Clamp Meter
High Resolution DC/AC 10mA
23mm Large Jaw Diameter
One Touch Zero for DCA
adjustment
Large 3 3/4 Digits LCD
(4032 Counts)
Fast Analog Bargraph Display
Max/Min, Data Hold
600Vrms Overload Protection for
Ohm Measurement
IEC 1010
CAT 300V
CAT 600V
AC/DC Current: 40A/0~150A/
150~200A
AC/DC Voltage: 400V
Resistance: 40~400 (beep if <
40.0 )
Frequency: 1~100KHz
TES ELECTRICAL ELECTRONIC CORP.
Features
QUALITY & RELIABILITY
21
CM-02 CM-05 CM-07 Prova 11
CM-02 AC/DC Clamp Meter Automotive Clamp
Features
IEC 1010
CAT 300V
CAT 600V
DC/AC 10mA Resolution
23mm Jaw Diameter
Auto Range V , A,,F and
Temperature
AC/DC 0.01~200A
One Touch Zero for DCA adjustment
3 3/4 Digits (4,032 Counts)
Capacitance & Diode Measurement
Temperature:, seletable
Max / Min, Date Hold
AC/DC Current: 40/200A
AC/DC Voltage:400m/4/40/400/600 V
Resistance:400/4K/40K/400K/4M/40M Frequency: 1~100KHz
Continuity :40~400 Temperature:-40~1000 -40~1800
CM-05 AC/DC Current Probe
Features
Accurate DC/AC current probe
10mADC, 1mAAC high
resolution
23mm Jaw Diameter
One Touch Zero for DCA adjustment
Easy single rotary switch for any
function selection
AC/DC Current:
4A/40A/150A/200A
Sensitivity:
0.1mV/1 mA
0.1mV/10 mA
0.1 mV/100 mA
IEC 1010
CAT 300V
CAT 600V
CM-07 TRMS AC/DC Clamp Meter
Features
TES ELECTRICAL ELECTRONIC CORP.
IEC 1010
CAT 300V
CAT 600V
High Resolution DC 10mA, AC 1mA
True RMS reading
Non-contact Current, Frequency Measurement
23mm Large Jaw Diameter
One Touch Zero for DCA adjustment
Large 3 3/4 Digits LCD(4032 counts)
Fast Analog Bargraph Display
Max/Min, Data Hold
AC/DC Current:
40A/150A/200A/400A (DC)
4A/40A/100A/200A/400A (AC)
Frequency: 1~100K Hz
Prova 11 AC/DC mA TRMS Clamp Meter
Features
IEC 1010
CAT 300V
CAT 600V
22 QUALITY & RELIABILITY
Super High Resolution-DC/1 mA, AC/0.1mA
True RMS
One Touch Zero for DCA adjustment
23mm jaw diameter
Lager 3 3/4 Digits LCD(4032 counts)
Fast bargraph display
Max/Min, Data Hold
AC/DC Current:
0~4A/30A/40A(DC)
400mA/4,000mA/30A(AC)
AC/DC Voltage: 400 V
Prova 1200 Prova 15 Prova 2000 / 2003 TES-3010 / 3012
Prova 1200 AC/DC Clamp Meter
Features
1,200A AC/DC current measure-
ment
Integrated current probe for
waveform observation or recording
One touch zero for DCA
adjustment
Fast bargraph display (30 times/
sec.) for transient observation
Max/Min and Data hold function
Ideal for works in crowded switch
box or cable areas
23mm Large Jaw Diameter
Large 3 3/4 Digits LCD
Fast bargraph display
DC Current: ( 2.0% + 3 dgts)
0~400A (0.1A), 0~1200A (1A)
AC Current:
0~400A (0.1A), 0~1200A (1A)
2.0% + 3 dgts 50/60 Hz
Analog Output:
AC/DC: 1 mV/A (0~400A)
AC/DC: 0.1 mV/A (0~1200A)
Prova 15 AC/DC mA Current Probe
Features
High Resolution DC 1mA,
AC 0.1mA
Connect to an Oscilloscope to
observe Current Waveform
Connect to Chart Recorder /
Datalogger/ DMM to Record
Current Data
One touch Zero for DCA
adjustment
23mm jaw diameter
IEC 1010
CAT 300V
CAT 600V
AC /DC Current:
400mA/4A/30A
Sensitivity:
0.1mV/ 0.1 mA
0.1mV/1 mA
0.1 mV/10 mA
Prova 2000/2003 AC/DC Clamp Meter
Features
IEC 1010
CAT 600V
CAT 1000V
DC 2500A, AC 2100A
55mm, Bus Bar 65mmx24mm
True RMS (Prova 2000)
Auto Range A, V, , Hz
DCA One Touch Zero
Diode Test
Continuity with buzzer
Max/Min/Hold
Relative Measurement
Large 3 3/4 Digits LCD
Fast bargraph display
Resistance measurement
Current: (AC/DC)
DC~400A/2500A
AC~400A/2100A
Current Analog Output:
400A/2,100A(1mV/A)
Voltage: (AC/DC)
DC~400m/4V/40V/400V/600V
AC~4V/40V/400V/600V
Frequency: (Hz) 1~100KHz
Features
Frequency Count, Diode Check &
Beeper
Peak/Data Hold
Unit & Sign Display
Current: (AC)
20/200/600A (TES-3010)
20/200/600/1,000A (TES-3012)
Voltage: (AC/DC)
DC-1,000V; AC-200V/750V
Frequency: (Hz) 2KHz
Ohms: (Resistance) 200 /20K TES ELECTRICAL ELECTRONIC CORP.
TES-3010/3012 Prof. Clamp Meter
QUALITY & RELIABILITY
23
TES-3040 TES-3050 TES-3082 TES-3092
TES-3040 AC Clamp Meter
Features
3-3/4 Digital LCD with bar-graph
Auto-power off with Data Hold &
MAX/MIN mode
Zero Adjustment/Relative
Reading
IEC 61010
CAT 600V
CAT 1000V
Current: (AC)
400/1,000A
Voltage: (AC/DC)
DC-400mV/4V/40V/400V/600V
AC-4V/40V/400V/600V
Resistance: (Ohm)
400/4K/40K/400K/
4M/40M
Frequency: (Hz)
100Hz/1KHz/10KHz/100KHz/
800KHz
TES-3050 TRMS AC/DC Clamp Meter
Features
3-3/4 Digital LCD with bar-graph
Auto-ranging off/Data Hold/
Peak Hold
MAX/MIN mode
Zero Adjustment/Relative
Reading
IEC 61010
CAT 600V
CAT 1000V
Current: (AC/DC)
400/1000A
Voltage: (AC/DC)
DC-400mV/4V/40V/400V/600V
AC-4V/40V/400V/600V
Frequency: (Hz)
100Hz/1KHz/10KHz/100KHz/
800KHz
Ohms: (Resistance)
400/4K/40K/400K/
4M/40M
TES-3082 TRMS AC/DC Clamp Meter
Features
True RMS Reading
4000 count Reading
AC/DC 600A
DCA One-touch-Zero
Current: (DC/AC)
( 1.9%rdg 5dgts)
400A/600A
Voltage: (DC/AC)
DC-600V; AC-400V/600V
Resistance: (Ohms)4K
Frequency: (Autorange)
4KHz/20KHz
TES ELECTRICAL ELECTRONIC CORP.
IEC 61010
CAT 600V
CAT 1000V
24 QUALITY & RELIABILITY
TES-3092 AC/DC Clamp Meter (700A AC/DC)
Features
Compact & Pocket Size
AC 700A & DC 800A
600V AC & 200V DC Ohm/
Continuity Beeper.
One Touch DAC Zero
EN 61010
CAT 600V
CAT 1000V
DC/AC Current:
200A/800A (DCA)
200A/700A (ACA)
DC/AC Voltage:
200V (DCV)
600V (ACV)
Ohms: 2K
Resolution: 0.1 A/1A, 0.1V/1V
Prova 5601 TES-1605 TES-1700
Earth / Ground Tester
Prova 5601 Clamp-on Ground Resistance Tester
Features
Non-Contact Ground Resistance
Measurement
No Auxiliary Electrode Needed
Jaw Diameter 23mm
0.2mA~30A True RMS
116 Sets of Memory
Programmable High and Low Alarm
Programmable Data Logging
Data Logging interval:1 to 255 sec.
CAT 600V
CAT 300V
EN61010-2-032
Ground Resistance:
0.025~0.250/0.251~1.000/
1.001~10.00/10.01~50.00/
50.01~100.0/100.1~200.0/
200.1~400.0/400.1~600.0/
600.1~1500 Ground/Leakage Current:
(50/60Hz, True RMS )
0.300~1.000/1.00~10.00/
10.0~100.0/100~1000mA
0.20~4.000A
4.00~30.00A
TES-1605 Digital Earth Tester
Features
Earth Resistance
(20/200/2000)
Zero ohm adjustment
Capable of measuring earth
voltage
Data hold function
Auto power off function
Earth voltage:
0.1V, (1% + 4)
Earth Resistance:
20/ (2% + 0.1)
200/2000/ (2% +3dgts)
Current Consumption:
Earth V: 22mA
20/200/2000: 42mA
Overload Protection:
Earth Voltage: 300Vrms/1 min
Earth Resistance: 200Vrms/
10 sec.
TES-1700 Earth Resistance Tester
Features
Auto power off function
2mA measuring current permits
Measuring Range:
0~399.9V (50Hz, 60Hz)
(1%rdg+4dgts)
Resistance:
0~39.99/0~399.9/0~3999
(2%rdg+3dgts)
Overload Protection:
Earth Voltage: 400Vrms/1 minute
Earth Resistance: 250Vrms/1
seconds.
Current Consumption:
Range
40 /400 /4000 Earth V
ON
42mA
22mA
TES ELECTRICAL ELECTRONIC CORP.
earth resistance tests with
tripping earth leakage current
breakers in the circuit under test
QUALITY & RELIABILITY
25
TES-1390 / 1392 TES-1393 / 1394S TES-92
E M F Tester
TES-1390/1392 EMF Tester (Single axis)
Features
Measures EMF (Electro Magnetic
Field) Strength
Data Hold/Pick Hold function to
capture the highest EMF strength
automatically
RS-232 Interface/Software for
TES-1392
Stand-alone Datalogging function
for TES-1392 (15,750 points)
Display:
3-1/2 digits, Max. indication 1999
Range:
200/2000 milli Gauss;
20/200 micro Tesla
Resolution:
0.1/1 milli Gauss; 0.01/0.1 micro
Tesla
Accuracy:
(3%+3d) at 50Hz /60Hz
Number of Axis: Single axis
Band Width: 30 Hz~300 Hz
Datalogging Capacity (TES-1392):
16,000 Points
Sampling Time:
Approx. 0.4 second
TES-1393/1394S EMF Tester (Three axis)
Features
Triple LCD display to show X.Y.Z.
axis each EMF Reading and plus
average reading X+Y+Z/3
MAX/MIN/AVG Reading
Stand-alone Datalogging function
RS-232 Interface/Software for
TES-1394
Display:
3-1/2 digits, Max. indication 1999
Range:
20/200/2000 milli Gauss
2//20/200 micro Tesla
Resolution:
0.01/0.1/1 milli Gauss
0.001/0.01/0.1 micro Tesla
Accuracy:
(3%+3d) at 50Hz/60Hz
(5%+3d) at 40 Hz/~/200Hz
Number of Axis: Three axis
Band Width: 30 Hz~2000 Hz
Data logging Capacity: 999
Points
Sampling Time: Approx. 0.5
second
TES-92 Electro Smog Meter
Features
TES ELECTRICAL ELECTRONIC CORP.
50MHz to 3.5GHz Frequency
26 QUALITY & RELIABILITY
range
For isotropic measurements of
electromagnetic fields
Non-directional (isotropic)
measurement with threechannel
measurement probe
High dynamic range due to threechannel digital results processing
Configurable alarm threshold and
memory function
Easy to use
Applications
High frequency (RF) electromag-
netic wave field strength measurement
Mobil phone base station
antenna radiation power density
measurement
Wireless communication applications (CW, TDMA, GSM, DECT)
RF power measurement for
transmitters
Wireless LAN (Wi-Fi) detection,
installation
Spy camera, wireless bug finder
Cellular / Cordless phone
radiation safety level
Microwave oven leakage
detection
Personal living environment EMF
safety
TES-593 AFLEX-3030 AFLEX-3001 / 3002
TES-593 Electro Smog Meter (3 axis)
Features
Frequency range 10MHz to 8.0GHz
3 axis isotropic measurements of
EMF
Non-directional (isotropic)
measurement with three-channel
measurement probe
High dynamic range
Configurable alarm threshold and
memory function
Easy & safe to use
Applications
High Frequency (RF) electromag-
netic wave field strength measurement
Mobile phone base station
antenna radiation power density
measurement
Wireless communication applications (CW, TDMA, GSM, DECT)
RF power measurement for
transmitters
Wireless LAN (Wi-Fi) detection,
installation
Spy camera, wireless bug finder
Cellular/Cordless phone radiation
safety level
Microwave oven leakage
detection
Personal living environment
EMFsafety
Flexible Clamp Meter
AFLEX 3030 Flexible AC Current Probe
Features
Three Current Ranges: 30A, 300A
and 3000A
Two Output Sensitivity (300mV
and 1V), Versatile for Measuring
Instruments
Flexible Shape for Cables and
Bus Bar
Max. 170mm Diameter
Suitable for Any Electrical System
Wide Bandwidth, Low Phase Shift
Low Battery Indication
EN 61010-2-032
CAT III 600V
Pollution Degree 2
AFLEX 3001/3002 Flexible AC Current Clamp
Features
EN 61010-2-032
CAT III 600V
Pollution Degree 2
Up to 3000A, True RMS
Direct Reading, no DMM required
True RMS measurement of A at with 1% of scale basic accuracy
True RMS measurement of V at with 0.5% basic accuracy (model 3002 only)
Fast peak function (39s for 50Hz, 33s for 60Hz)
Max, Min and data hold functions.
Auto Power off function in 15 minutes
AC Current
Range: 5-300.A / 300.0-999.9A / 1000-3000A
Resolution: 0.1A / 0.1A / 1A
Accuracy of Readings: 1% of range
AC Voltage (AFLEX 3002 only)
Range: 4.0V-600.0V
Resolution: 0.1V
Accuracy of Readings: 0.5% 5dgts
Frequency of ACV (RMS value > 30VAC ) or
ACA (RMS value > 30A)
Range: 45-65
Resolution: 0.1
Accuracy of Readings: 0.2Hz
TES ELECTRICAL ELECTRONIC CORP.
QUALITY & RELIABILITY
27
AFLEX-3060 Prova 19 / 21 / 23 Prova 6603 / 6605
)
AFLEX 3060 Flexible AC Current Probe (6000A, 36
Features
Three current ranges: 60A, 600A, 6000A
Two output sensitivity (600mV and 1V), versatile for measuring
instruments
Suitable for any electrical system
Wide bandwidth: 10 to 10KHz
Low phase shift
Low battery indication
Probe length: 36 in. / 920 mm
EN 61010-2-032
CAT III 600V
Pollution Degree 2
Harmonic Clamp Meter
Prova 19/21/23 Leakage and Harmonics Tester
Harmonic Analysis (V and A) to the 99th
Order
Better Understanding of High Frequency
Harmonic Analysis (up to 5/6 KHz)
Analysis of Total Harmonic Distortion
(THD-F)
Analysis of Crest Factor (C.F.)
Fast Peak Function (33 s and 39 s)
Prova 21 (50A) and Prova 23 (100A)
EN 61010-2-032
CAT III 300V CAT II 600V
Pollution Degree 2
Features
True RMS value (V and A)
Leakage Current Measurement at 10 A
Resolution
W, KW, H.P.
VA, KVA, VAR, KVAR
PF, Phase Angle ()
Energy (mWH, WH, KWH)
Analysis of Standby Power Consumption
Balanced 3 Power Quality and
Sequence
AC Watt (Prova 21/23)
Range: 0.050W~9,999KW
AC Current (50 or 60 Hz, True RMS)
Range: 0.5~50A (19,21)
0.5~100A (23)
TES ELECTRICAL ELECTRONIC CORP.
28 QUALITY & RELIABILITY
Prova 6603/6605 Power and Harmonics Tester
Features
EN61010-2-032
CAT 600V
Pollution Degree2
AC Voltage (50 or 60 Hz, True
RMS)
Range: 5V~600V
Harmonics of AC Voltage in % and
Magnitude (1~99th order)
Range: 50V~600V
Harmonics of ACA in %
Percentage and Magnitude
(1~ 99th order)
Range: 0.5~50A(19, 21)
0.5~100A(23)
Power Factor and Phase
Angle (21 & 23)
Range (PF): 0.000~1.000
Range (): -180 ~180 (0 ~360 )
Total Harmonic Distortion (THD-F,
1~50th order)
Range: 0.0~999.9 %
Crest Factor (C.F.,Accuracy of
Readings)
Range: 1.00~99.99
Active (W, KW, HP), reactive (VAR,
KVAR) and apparent (VA, KVA) power
Power factor (PF), phase angle (), and
energy (WH, KWH)
Non-interrupted AC current harmonic
analysis
1 to 99th order of harmonics at
2.0% basic accuracy
Total harmonic distortion (%THD-F) and
crest factor (CF)
True RMS measurement of V and A
Fast peak function (39 s for 50Hz, 33 s for 60Hz)
Resistance and Continuity with Beeper
Measurement of balanced 3 power
Measurement of balanced 3 sequence
Programmable CT ratio from 1~ 250
Max, Min and data hold functions.
Active power in H.P.
Auto power off function in 30 minutes
Prova 6603: 0~750A,
Prova 6605: 0~1,500A AC Watt
Range: 10.0W~9999KW
Accuracy: 2% 20dgts
AC Current
Range: 10.0~750.0A (6603)
10.0 ~ 1500.0A (6605)
Accuracy: 2% 5dgts
AC Voltage
Range: 10.0V~600.0V
Accuracy: 0.5% 5dgts
Harmonics of AC Voltage in Percentage
Range: 1st~99th Accuracy: 2%
Harmonics of AC Current in Percentage
Range: 1st~99th Accuracy: 2%
Power Factor (PF)
Range: 0.000~1.000 Accuracy: 0.04
)
Phase Angle (
Range: -180 ~180 / 0 ~360 Accuracy: 2 Total Harmonic Distortion
Range: 0.0~999.9% Accuracy: 2%
TES-1260 TES-1360A TES-1361C
Humidity Temp. Meter
TES-1260 Humidity Temperature Meter
Features
Slimiline and Stylish
Large Dual LCD display
Dew Point Reading / Wet Bulb
Reading
MAX/MIN with Time Stamp
Data Hold function
/ Switchable
Data memory and read function
(99 readings from LCD display)
Auto Power Off
Range:
Temperature:
-20~60 (-4~140)
Humidity: 1%RH ~ 99%RH
Resolution: 0.1/0.1/0.1%RH
Accuracy:
Temperature: 0.5, 0.9
Humidity:
3%RH (at 25, 30~99%RH)
5%RH (at 25, 1~30%RH)
Data Memory Capacity:
99 sets reading from LCD display
TES-1360A Humidity/Temperature MeterFeatures
Features
Ideal for: Laboratory, Quality
Control, Air Conditioning &
Process Engineering
Instant performance of Humidity
measurement by Precision thinfilm capacitance sensor.
High Resolution of 0.1% R.H.,
0.1 & 0.1
Data Hold function to hold the
LCD reading.
Data memory and read function
(99 sets)
Range:
Humidity: 10%~95% R.H.
Temperature: -20~+60 /
-4~+140
Resolution: 0.1% R.H. 0.1, 0.1
Accuracy (after calibration)
Humidity: 3% R.H.
Temperature: 0.8, 1.5
Auxiliary outputs:
Humidity: 10mV DC/1% R.H.
Temperature: 10mV DC/1,
10mV DC/1
TES-1361C Datalogging Humidity/Temperature Meter
Features
& Temp) with Data/Time Stamp
Switchable Main display &
Secondary display
Dual display with time clock
Accurate & Easy Operation
RS-232 interface (software
included)
Range:
Humidity: 10%...95%R.H.
Temperature: -20~+60/-4
~+140
Accuracy:
Humidity: 3%R.H. (at 25,
30~95%R.H.)
Temperature: 0.8, 1.5
Record: (Data logging)
7000 Point Data logger (Dual Data)
TES ELECTRICAL ELECTRONIC CORP.
Logging 7000 dual Reading (RH%
QUALITY & RELIABILITY
29
TES-1362 TES-1364 / 1365 CM-03
TES-1362 Printing Humidity/Temperature Meter
Features
Triple LCD Display for RH%
Humidity, T1 for air, T2 for Type K
Dew Point Reading
Max/Min/Data Hold
Real Time Stamp
Periodically Print out from PreSet time interval
Range:
T1: Temp.: -20~60
(-4~140) / ( 0.8, 1.5)
Humidity: 10%RH~95%RH
( 3%RH)
T2: Type K: -200~1333
(-58~2431) /
(0.1%rdg + 0.8)
Resolution: 0.1/0.1/0.1%RH
Sampling Rate: 1 time/sec.
TES-1364/1365 Datalogging Humidity/Temperature Meter
Features
Data Hold & Relative function
Dual LCD display with Bargraph
indication
Automatic Timer Recording for
Datalogger(TES-1365)
Dew Point Reading & Wet Bulb
Reading
MAX/MIN with Time Stamp
Data Memory and Read function
(99 readings from LCD display)
Datalogging capacity 15,000 dual
reading (%RH & Temp-TES-1365)
RS-232 Interface & window software
(TES-1365)
Range:
Temperature:-20~60(-4
~140)
Humidity: 10%RH~95%RH
Resolution: 0.1/0.1/0.1% RH
Accuracy:
Temperature : 0.5, 0.9
Humidity:
3%RH(at 2530~95%RH)
5%RH(at 2510~30%RH)
Datalogging: (TES-1365)
Continues Recorder: 15,000 data
sets.
Leakage Current Tester
CM-03 Leakage Current Tester
TES ELECTRICAL ELECTRONIC CORP.
Features
IEC 1010
CAT 300V
CAT 600V
30 QUALITY & RELIABILITY
10uA Ultra High Resolution on 40mA range
30mm Large Conductor Diameter
ACA 5 Range (40mA, 400mA, 4A, 40A, 60A)
Fast bargraph display (30 times/sec.)
Max/Min, Data Hold function
Relative measurement
AC Current:
( 1.0% rdg 3dgts)
40m/400m/4A/40A/60A
AC Voltage: 400V
Resistance and Continuity: 40~400 TES-1600 TES-1601 TES-1604
Insulation Tester
TES-1600 Insulation Tester
Features
2000M /1000V, 200M /500V, 200M /250V
Power lock for 3 minutes
(Auto power off)
Auto-Zero adjustment
Data-Hold-Function/Continuity Beeper
1mA Test Current
IEC 1010
CAT 300V
CAT 600V
AC Voltage: 600V
MEG OHMS: ( 3%rdg 5Ct)
200M /250V
200M /500V
2000M /1000V
OHMS: 200 TES-1601 Auto Ranging Insulation Tester
Features
IEC 61010
CAT 300V
CAT 600V
4,000 M /V Reading/ 10,000M analog indication
"Test Hold" function
Backlight illumination
1mA Test Current
200mA short Circuit continuity current
AC Voltage: 600V ACV
Continuity: 400 Ohm (Ish>200mA)
MEG OHM: ( 3%rdg 5Ct)
4000M /250V w/autorange
4000M /500V w/autorange
4000M /1000V w/autorange
Autorange: 4000M/400M/40M/4M
TES-1604 Datalogging Insulation Tester (RS-232)
Features
IEC 1010
CAT 600V
CAT 1000V
Auto Range for Mega ohm range
200mA short circuit continuity current
Via RS-232 interface to talk with PC
7000 Record data logging capacity
AC Voltage:
600V ACV (1.5% rdg +3 dgts)
Continuity:
40 Ohm (1sh > 200mA)(1% rdg +30dgts)
Mega OHM: ( 3% rdg 5Ct)
4000M /250V w/auto-range
4000M /500V w/auto-range
4000M /1,000V w/auto-range
Auto-range: 4,000M/400M/40M/4M
TES ELECTRICAL ELECTRONIC CORP.
QUALITY & RELIABILITY
31
TES-3660 TES-45A TES-46
TES-3660 Autoranging Insulation Tester
Features
Large LCD with analog bar graph
and digital display
250V, 500V, 1000V output
voltage for insulation M testing
10G insulation testing with
CAT 1000V
utomatically switch to voltage
easurement
Lo function for testing connections
Last reading HOLD display
Auto discharge of capacitive
voltage charges
AC/DC voltage measurement up
to 999V
Manual data memory and read
function (9 sets)
Mega OHM:
( 3% rdg 5Ct < 1G ;
5% rdg 5Ct > 1G )
10G /250V, 10G /500V, 10G
/1000V
w/auto range (4M/40M/400M/
4000M/10G )
Lo : 40.00 ( 2% rdg 2dgts)
AC Voltage (50~400Hz):
999V ( 2% rdg+2 dgts)
DC Voltage:
999V( 1% rdg+2dgts)
Resistance:
9999 Ohm ( 1% rdg+3dgts)
LAN Cable Tester
TES-45A LAN Cable Tester
Features
Check Open, Short, Reversed,
Crossed & Split wires of wiring
faults
8 different cablesremoteidentifiers available (#1,
#2, #3, #4, #5, #6, #7, #8)
Double digits LED display and
plus 4 pairs LED to show wiring
fault status/pairing test
Connector: RJ45, BNC
Cable pairs tested: 1/2, 3/6, 4/5,
7/8
Faults status: Open, Short,
Reversed, Crossed, Split and Low
Battery
Test Cable length:
Maximum 150M (492 ft)
Accessories:
One Patch Cable (RJ45 to RJ45,
30cm long) & One Remote
Identifier #1
Optional for A #2, #3, #4 for B #5,
#6, #7, #8
TES-46 LAN Cable Meter
Features
TES ELECTRICAL ELECTRONIC CORP.
Detects Wiring Problem: Open,
32 QUALITY & RELIABILITY
Short, Reversed, Crossed & Split
wires
Locates wiring/connection errors
(distance to the open or short)
Measures cable length(2~1000 ft/
1~350M)
Can identify up to 8 different
cables at one end by provided
remote identifiers
Display: 2 lines characters LCD
display
Connector: RJ45, BNC
Category: CAT3, CAT4, CAT5,
User-Calibration
Resolution:
0.5 M/0.5ft < 100 M/100 ft
1 M/1ft > 100 M/100 ft
Accuracy: (5%+1M)/ (5%+3ft)
TES-1330A / 1332A / 1334A TES-1335 TES-1336A
Light Meter
TES-1330A/1332A/1334A Light Meter
Features
Cosine Angular corrected
Analog output jack for recording
(1332A/1334A)
Data Hold function, Peak Hold
function for 1334A
Range: ( 3% rdg 0.5%f.s.)
20/200/2,000/20,000
Lux for TES-1330A
200/2,000/20,000/200,000
Lux for TES-1332A
20/200/2,000/20,000Lux/Footcandle for TES-1334A
20,000 lux-reading x10; 200,000
lux-reading x100
Over-range Display:
Highest digit of (1) is displayed
TES-1335 Light Meter
Features
Cosine Angular corrected
Relative function
Auto-Power off function
Accurate and instant response
Peak Hold function
Data Hold, MAX/MIN function
Range:
40, 400, 4,000, 40,000, 400,000 Lux
40, 400, 4,000, 40,000 fc
Accuracy:
3% rdg 0.5% f.s.
4% rdg 10 dgt as >10,000 lux/fc
Resolution: 0.01LuxCIE V function f'1 6%
Over-range Display:LCD will show
"OL" symbol
TES-1336A Datalogging Light Meter (RS-232)
Features
Spectrum of photo sensor meets
Range: ( 3% rdg 0.5%f.s.)20/
200/2,000/20,000 Lux
20/200/2,000/20,000 Fc,
(20,000 Lux/Fc range reading x 10)
Display: 31/2 digit LCD
Measuring Rate: 2.5 times/sec.
TES ELECTRICAL ELECTRONIC CORP.
C.I.E. photopic curve V()
16000 Records Data logging
capacity
RS-232 interface (software
included)
Measurement of Luminousintensity (PC Software)
QUALITY & RELIABILITY
33
TES-1337 TES-1339 / 1339R TES-1800
TES-1337 Light Meter
Features
Spectral Sensitivity close to CIE
photopic Curve
Accurate and instant response
Data Hold function
MAX/MIN function
Relative function
Range: ( 3% rdg 5 dgt)
20, 200, 2,000, 20,000 Lux
20, 200, 2,000, 20,000 fc
Accuracy:
3% rdg 0.5% f.s.
4% rdg 10 dgt as > 10,000 lux/fc
Resolution: 0.01Lux CIE V function f'1 6%
Over-range Display:LCD will
show "OL" symbol
TES-1339 / 1339R Light Meter Pro. (RS-232)
Measuring Levels Ranging 0.01
Features
Dual Display 4-digit LCD reading
Spectral Sensitivity close to CIE
photopic Curve
to 999900 Lux, 0.001 to 92927 fc,
Autoranging 5 steps
Accurate and Instant Response
Integral illuminance measurement
Luminous Intensity measurement
Reference value setting for
relative or percentage deviation
measurement
Ripple Measurement for STRAY
& LIGHT function
Time-Hold measurement
Point-average function
Comparator function
Auto power off function
Data Hold function
CNS 5119 Class II
Data memory and read function
(99 readings)
Data Logging function (40,000
readings) (TES-1339R)
RS-232 Interface & Software
(TES-1339R)
3% rdg 5 dgt):
Range (
99.99, 999.9, 9999, 99990,
999900 Lux / 9.292, 92.92, 929.2,
9292, 92927 fc.
Auto ranging (5 step)
(1fc = 10.76 Lux)
Resolution: 0.01 Lux, 0.001 fc
Over range Display: OL is displayed
1: 6%
CIE photopic f
Temperature Characteristics:
0.1%/
Measuring Rate: 5 time/sec (approx.)
Data Memory Capacity: 99 sets
(Direct reading from LCD display)
Data Logger Capacity: 40,000 sets
(TES-1339R)
Loop/ PSC Tester
TES ELECTRICAL ELECTRONIC CORP.
TES-1800 Loop/PSC Tester
34 QUALITY & RELIABILITY
Features
Auto lock out if test resister
overheats
Measure low loop with 0.01
resolution
High loop range permit measurement of ground spikes.
1800A 230V
1800B 110V
IEC 61010-1
CAT 300V
Range: 20/200/2000 Accuracy: (2%+2digit) at 1 on
20range
Lowest Resolution: 0.01
Voltage Display: 2%+1digit
AC Test Current: 25A nominal at
20 Range
AC Test Period: 20ms
PSC Range: 200A/2000A/20KA
Operation Voltage: 230V 10%,
50Hz 1%
Fuse Protection: HRC ceramic
fuse
TES-1900 Prova 700 / 710 Prova 803
RC D Tester
TES-1900 Digital RCD Tester
Features
3 LED's for checking wiring status
0 and 180 degree phase angle
switch permits quick tests and
consistent readings
Digital read out of tripping time
Visual indication of reversed
phase and neutral wring at socket
Resilient case made from modern plastics to take everyday
knock and brings
1900A 230V
1900B 110V
Rated Tripping Current: 10/20/30/
100/300/500mA
Fault Condition Setting: X1/2, X1, X5
Fault Trip Time: 2000ms, 40ms (X5)
Low Set Resolution:
1ms (X1/2, X1), 0.1ms (X5)
Trip Time Accuracy:
(1% rdg + 2 digits)
Operation Voltage:
230V 10%, 50/60Hz
Milli / Micro-Ohmmeter
Prova 700 / 710 Milli / Micro-Ohmmeter
Features
Max. Test current: 5A (Prova
700)
Max. Test Current: 10A (Prova
710)
Four Terminal Kelvin
measurement.
Best resolution 1 .
Basic accuracy 0.25%.
Manual or Auto Range.
Measurement of resistive and
inductive materials.
Readings Hold function.
Cable length measurement
Large LCD (5-digit) with backlight
Low battery (voltage) alarm.
Low Power consumption
Rechargeable lithium batteries
and AC adaptor
RS232C (to USB bridge) cable
Built-in calendar clock
Built-in batteries charging circuit
Application
Coil resistance of Electric motor
Contact resistance of Switch and
Relay
Resistance of Bus bar, Breaker,
Fuse, Inductance and Shunt
Multimeters
Prova 803 Precision Multimeter (Mobile Bench-top) DMM
60,000 Counts Dual Channels
0.04% DC Basic Accuracy, 0.2%
AC Basic Accuracy
10KHz (max.) bandwidth
Fast ACV, ACA Response
Standalone Data Logging of
IEC 61010-1
CAT 1000V
CAT 600V
10708 Records for both channels
Study of Relationship of Voltage
and Current with One DMM
Dual Display of Frequency and
Duty Cycle
Record Data of Both Channels
Using a PC through the RS-232C
interface
DCV/ACV: 60.000mV ~ 1000.0V
DCA/ACA: 600.00 A ~ 10.000A
Resistance: 999.99 ~ 40.000m Capacitance: 60.00nF ~ 999.9 F
Frequency: 1.000Hz ~ 2MHz
Duty-Cycle and Diode-Test
TES ELECTRICAL ELECTRONIC CORP.
Features
QUALITY & RELIABILITY
35
Prova 901 / 903 TES-2620 TES-2700
Prova 901/903 Precision Multimeter (Mobile Bench-top) DMM
Features
60,000 Counts Dual Channels
0.03% DC Basic Accuracy, 0.1%
IEC 61010-1
CAT 1000V
CAT 600V
AC Basic Accuracy
200KHz (max.) bandwidth and
True RMS
Fast ACV, ACA Response
Standalone Data Logging of
10708 Records (for Prova 903
only)
Study of Relationship of Voltage
and Current with One DMM
Dual Display of Frequency and
Duty Cycle
Record Data of Both Channels
Using a PC through the RS-232C
interface
DCV/ACV: 60.000mV ~ 1000.0V
DCA/ACA: 600.00A ~ 10.000A
Resistance: 999.99~ 40.000m
Capacitance: 60.00nF ~ 999.9F
Frequency: 1.000Hz ~ 2MHz
Duty-Cycle and Diode-Test
TES-2620 (3 3/4 Digits) True RMS Multimeter
Features
3 3/4 Digital LCD with Bar-graph
Water-Proof ABS housing
Auto-power off
Auto ranging
ADP range to accommodate
Current, Temp., Humidity adaptor
Current: (AC/DC)4m/40m/400m/
20A
Voltage: (AC/DC)
( 0.5% rdg 1 dgt)
400m/4/40/400/750V (AC)/1000V
(DC)
Resistance:
400/4K/40K/400K/4M/40M
Frequency:
100/1K/10K/100K/500K Hz
TES-2700 Auto Ranging Multimeter
TES ELECTRICAL ELECTRONIC CORP.
Features
36 QUALITY & RELIABILITY
Autoranging and Auto-power-off
3200 count LCD analog bar-graph
Data-hold mode available at
ohms
Overload protection up to 600
Vrms
IEC 61010-1
CAT 300V
CAT 600V
Current:
320u/3.2m/32m/320m/20A
Voltage: (AC/DC)
( 0.5% rdg 2 dgt)
320m/3.2/32/600V (DC)
3.2/32/320/600V (AC)
Resistance:
320/3.2K/32K/320K/3.2M/30M TES-2712 TES-2732A Prova 8000
TES-2712 LCR Multimeter
Features
3 1/2 LCD
Data-hold and Peak-hold function
available
Inductance, Capacitance & ohm
measurement
Current:
200 /2m/20m/200m/20A
Voltage: (AC/DC)
( 0.5% rdg 1dgt)
200m/2/20/200/600V (DC)/600V (AC)
Capacitance:
2000P/200n/2F/20F
Inductance: 20m/200m/2/20H
Resistance: 2K/20K/200K/2M/20M
IEC 61010-1
CAT 300V
CAT 600V
TES-2732A Data Logger Multimeter (RS-232)
Features
DMM talks with PC via RS-232
interface
Data logger function
(4,808 readings)
Direct input of V, A, Ohm, Hz,
Cx&/ without any further
signal modification
Current: (AC/DC)
200u/2m/20m/200m/20A (AC/DC)
Voltage: (AC/DC)
( 0.5% rdg 1 dgt)
200m/2/20/200/600V (DC)/600V (AC)
Frequency:
( 0.5% rdg 2 dgts)
10Hz~20M Hz (Auto range)
Resistance:
200/2K/20K/200K/2M/20M
Capacitance:
2000P/200n/2F/20F
IEC 61010-1
CAT 300V
CAT 600V
Power Supply
Prova 8000 Programmable Power Supply
Switching Technology, Analog
Quality
1+2 Output 200w
One Programmable Output
0-40V/5A
Two Fixed Outputs 5V/2A, 3.3V/
3A
1mV, 1mA High resolution
3mVrms, 3mArms low noise
High Stability, Low Drift
Over-Voltage, Over-Current
Protection
OCP with Programmable Timer
Built-in Buzzer Alarm
200 Sets Memory
Easy RECALL & STORE function
AUTO-STEP function with
programmable interval
Stand by/Operate Button
Bi-direction RS-232C interface
TES ELECTRICAL ELECTRONIC CORP.
Features
QUALITY & RELIABILITY
37
Prova 8500 TES-3600 AFLEX 3003 / 3005
Prova 8500 Electric Energy-Saving Tester
Features
AC Power Supply + AC PowerMeter
Standby Power Measurement of
Note Book, Desktop PC, LCD TV, ˇ
Two Measurement Terminals:
a. Programmable nominal output:
85V~250V, 45Hz~65Hz.
b. External power input: max.
2000W
High Resolution (0.1V, 0.1mA),
High Stability and Low Drift
Power Quality Measurement (W,
PF, V, A, harmonics)
PC Programmable through RS232C Interface (included RS-232C
to USB Bridge)
Programmable Over Current
Protection (OCP)
Memory of 99 Preset Voltage and
Frequency
LCD display for monitoring output
V, A, W
Cost Calculation based on a Day,
a Month or a Year.
230V/115V Selectable by Switch
Specifications of Front Panel
(AC Sine Wave Output)
Range
Resolution
Accuracy
85V 250V
0.1V
1%
45Hz - 65Hz
0.01Hz
0.1 Hz
0.01W - 100W
0.001W
1 % 0.1W
0.5A - 1.5A
0.001A
1 % 0.05A
PF (0 ~ 1)
0.001PF
0.04
Specifications of Rear Panel
(Max. 2000W, AC Measurement)
Range
Resolution
Accuracy
0.1W 0.001W/ 0.01W 1 % 0.1W
2000W
/ 0.1W/ 1W
85V - 250V
0.1V
1%
0.01A - 10A
0.001A/0.01A 1 % 0.05A
PF (0~1)
0.001PF
0.04
45Hz - 65Hz
0.01Hz
0.1Hz
THD
0.1%
2%
Hn(1~50th) 0.1mA/0.001A/0.01A 1.4 %
Power Analyzer
TES-3600 3 phase Power Analyzer
Features
probes
1P2W, 1P3W, 3P3W2M, 3P4W
Power Measurement
True RMS Sensing
Power KW, KVAR, KVA, PF, , Hz &
CAT 1000V
TES ELECTRICAL ELECTRONIC CORP.
LVD
CAT 1000V
Range:
V: 999.9V ( 0.3% rdg 10dgts)
A: 999.9A ( 0.5% rdg 15dgts)
KW: 999.9KW ( 1% rdg 20dgts)
KVA: 999.9KVA ( 1% rdg 20dgts)
KVAR: 999.9KVAR( 2.5% rdg 20dgts)
Power Factor: -1~0 ~ +1 ( 1% rdg 40dgts)
Phase Angle: 0~ 15 ( 6.0 )
15 ~ 75 ( 3.0 )
75 ~ 90 ( 6.0 )
Hz: 0.01~60Hz ( 0.1%rdg 2dgt)
Three Phase Sequence Detection:
3P > 50V
Power Energy Measurement
(Wh, Vah, VARh): 119.3M
Wh: 1% rdg 20 dgts
VAh: 1% rdg 20 dgts
VARh: 1% rdg 20 dgts
Harmonic Measurement: 1~31( 3% THD)
10 Display Easy-to-View LCD screen
Connectors for 4 Current Clamp
Energy KWh, KVARh, KVAh Measurement
Manual Data Memory and Read (99
sets)
Datalogging (504KB memory, 20,000
sets)
Programmable Trigger-Points and
Start/Stop Time
RS-232 Optical Interface with three
phase voltage/current Waveform
display and Harmonic analysis
TES-3600A for 220V
TES-3600B for 110V
AFLEX 3003/3005 Flexible VA Harmonics/
Power Quality Tester
Features
Power Analysis (3005)
EN 61010-2-032
CAT III 600V
Pollution Degree 2
38 QUALITY & RELIABILITY
W, KW, H.P.
VA, KVA, VAR, KVAR
PF, Phase Angle ()
Energy (WH, KWH)
Dual displays (W+PF,
VA+KVAR)
Balanced 3 Power Quality
Balanced 3 Sequence
Harmonics Analysis (3003, 3005)
True RMS (V and A)
3000A
Non-interrupted Harmonic Analysis (V
and A) to the 50th Order in % and
Magnitude
Fast Peak Function (33s and 39s)
Programmable VT (1 to 3000) Ratios
Auto-Power-Off: 30 minutes
Analysis of %THD-F and C.F.
Max, Min, Date hold functions
AFLEX 6300 Prova 6830A+6801 / 6802 / 6803 / 3006 / 3009 WM-01 / 03
AFLEX 6300 Graphic Power Quality Analyzer
True RMS Value (V and I)
Active Power (KW), Apparent (KVA)
and Reactive Power (KVAR)
Power Factor (PF), Phase Angle
()
Energy (WH, KWH, KVARH, PFH)
Display of Overlapped Voltage and
Current Waveform
Max. Demand (MD in W, KW, MW)
with Programmable Period
Harmonics Analysis (V & I) to the
50th order
Display of 25 Harmonics in One
Screen with Waveform
Features
Display of Waveform with Peak
Values (512 Samples/Period),
Analysis for Single Phase and
Balanced 3 Phase Systems
Prova 6830A+6801/6802/6803/3006/3009
Power and Harmonics Analyzer
Current Measurement:(TRMS)
Features
Analysis for 3P4W, 3P3W, 1P2W,
1P3W
True RMS Value (V123 and I123)
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA,
KVAR)
Power Factor (PF), Phase Angle()
Energy (WH, KWH, KVARH, PFH)
Datalogging of 32, 64, 128 or 256
Points/Cycles
Analysis of Total Harmonic
Distortion (%THD-F)
Graphic Phasor Diagram
Transient detection and logging of
Swell, Dip and Outage(Max.
32000 events)
Data Logging Memory Size: 512K
bytes
Output of Waveform, Power
Parameters and 50 Harmonics at
Command
Large Dot Matrix LCD Display
with Backlight
Prova 6830A+6801: 0.04A ~ 100A
Prova 6830A+6802: 0.4A ~ 1000A
Prova 6830A+6803: 10.0A ~ 3000A
Prova 6830A+3006: 20.0A ~ 6000A
Prova 6830A+3009: 6.0A ~ 1200A
Display of 35 Parameters in One
Screen (3P4W)
Voltage and Current Waveform
Average Demand (AD in W, KW,
MW)
Maximum Demand (MD in W, KW,
MW) with Programmable Period
Harmonic Analysis to the 99th Order
Display of Waveform with Peak
Values (1024 Samples / Period)
Analysis of Total Harmonic Distortion (%THD-F)
Graphic Phasor Diagram with 3
Phase System Parameters
Capture 28 Transient Events (Time
+ Cycles) with Programmable
Threshold (%)
DIP, SWELL, and OUTAGE are
included in transient events
Calculate Unbalanced Current
through Neutral Line (In)
512K Memory with Programmable
Interval (Sampling time from 2 to
3000 seconds, 17,000 records for
3P4W system)
Large Dot Matrix LCD Display
with Backlight
Optical isolated RS232C to USB
Interface
Built-in Timer and Calendar for
Data Logging
Conductor size:
Prova 6801: 30mm
Prova 6802: 55mm
Flexible probe length:
Prova 6803: 610 mm/24 in
AFLEX 3006: 920 mm / 36 in
AFLEX 3009: 460mm / 18in
Range selection: manual
Prova 6801: 1A, 10A, 100A
Prova 6802: 10A, 100A, 1000A
Prova 6803: 300A, 3000A
AFLEX 3006: 600A / 6000A
AFLEX 3009: 120A, 1200A
Features
Solution for better PF
4 LCD Displays with W, PF, V, A
Easy Plug-in and Test
RS-232 Computer Interface
Software for:
1. Phase Angle
2. Apparent Power
3. Reactive Power
4. Kilo- Watt Hour
5. Estimated kilo-Watt per day/
month/year
6. Energy Cost/Kwh
7. Serial Number/record print
out of your appliance measured
Watt: (Auto Range, AC+DC)
200/ 2,000 ( 0.9%rdg 5dgts)
Voltage: (True RMS, Auto
Range , AC+DC)
200/750 ( 0.5%rdg 4dgt)
Current: 2/20A(AC+DC)
Frequency: 40-20KHz
TES ELECTRICAL ELECTRONIC CORP.
WM-01/03 Power Analyzer / Datalogger
QUALITY & RELIABILITY
39
Prova 6200 Prova 6600 Prova 6601
Prova 6200 Graphic Power Quality Analyzer
Features
Analysis for Single Phase and
Balanced 3 Phase System
True RMS Value (V and I)
Active Power (W, KW, MW, GW)
Apparent Power (VA, KVA, MVA)
Reactive Power (VAR, KVAR,
MVAR)
Power Factor (PF), Phase Angle
()
Energy (WH, KWH, KVARH, PFH)
Programmable VT (1 to 3000)
Ratios
Display of Overlapped Voltage and
Current Waveform
Maximum Demand (MD in W, KW,
MW) with Programmable Period
Harmonic Analysis (V and I) to the
50th Order
Display of 25 Harmonics in One
Screen
Waveform Datalogging of 32, 64,
128 or 256 points/cycles
Analysis of Total Harmonic Distor-
tion (%THD-F)
Graphic Phasor Diagram
Transient detection and logging of
Swell, Dip and Outage(Max. 32000
events)
50,000 Records with Programmable Interval (1 to 6,000 seconds)
Real-time Output of Waveform,
Power Parameters and Harmonics
at Command
Large Dot Matrix LCD Display with
Backlight
Optical Isolated RS-232C Interface
Smart Datalogging to Save Battery
Power for Long-term Monitoring
Built-in Calendar Clock for Data
Logging
Power Clamp Meter
Prova 6600 3 Phase/1 Phase Power Clamp
Features
3 4W, 3 3W, 3 Balanced, 1
AC+DC 2000KW (3 ), 1200KW (1
2W, 1 3W
IEC 1010
CAT 600V
CAT 1000V
)
Dual Display W +PF, KVA +KVAR,
A+Hz, V+Hz, V+A
Phase Angle, Phase Sequence
Indication
AC+ DC 600V, 2000A, Power
Factor
AC/DC Auto Detection
AC+DC True Power:
0~99.99/100~999.9/ 1,000~1,200KW
AC + DC Voltage:(TRMS)
0~200V/200~500V/500~600V
AC+DC Current:(TRMS)
( 1.5%rdg 5dgts)
0~200/200~500/500~2,000A
Prova 6601 3 Phase PF Power Clamp
TES ELECTRICAL ELECTRONIC CORP.
Features
40 QUALITY & RELIABILITY
PF (3 4W, 3 3W,1 2W)
AC+DC 2000KW (3 ), AC+DC
1200KW (1 )
Dual Display W+PF,KVA +KVAR,
IEC 1010
CAT 600V
CAT 1000V
A+V,V+Hz
AC+DC 600V, 2000A
AC/DC Auto Detection
Memory of 4 records
Auto range
AC + DC True Power:
( 2%rdg 0.05KW)
0~99.99/100~999.9/
1000~1,200KW
AC + DC Voltage:(TRMS)
0~200V/200~500V/500~600V
AC+DC Current:(TRMS)
( 1.5%rdg 5dgts)
0~200/200~500/500~2,000A
AC + DC KVAR:
0~99.99/100~999.9/
1,000~1,200KW
TES-3063 TES-3079M TES-1350A
TES-3063 Datalogging Power AC/DC Clamp Meter
Features
True Power/Apparent/Power
Factor
RS-232 interface to talk with PC
Dual display KW+PF, KVA+PF,
V+A, A+Hz, V+Hz
Datalogging Capacity (4000
Reading)
Peak/Max/MIN function
CB
IEC 61010-1
CAT 600V
CAT 1000V
DCA/ACA/DCV/ACV:
DCA & ACA-1000A
DCV & ACV-600V
Peak Indication:
20~80A, 80~1000A
20~80V, 80~600V
Resistance: 10K
Frequency (Hz): 1KHz/5KHz
True Power & Apparent Power
Measurement:
V<130V, A<150A/V>130V, A
<150A/V<130V, A>150A/V >
130V, A>150A
TES-3079M Power/HVAC Trms Clamp Meter (1000A)
Features
HVAC Application :
Electrical Application :
Check for energized circuits and
Check current draw in motors and
compressors.
Use MAX/MIN/Recording in the
temperature mode to assess
efficiency.
Test run/start capacitors.
Confirm low voltage control
signals.
Measure current draw of flame
safeguard device
Confirm power sources
Analyze temperature and voltage
or current data with the aid of the
time stamp.
Insulation test up to 100M .
balanced loads.
1 / 3 (3P3W/3P4W) Power
analyzer.
Evaluate electrical contacts.
Capture motors in-rush current
readings.
Determine peak power demand
periods.
Verify line voltage stability.
Monitor motors and other loads for
excess heat.
Check motors run/start capacitor
values.
ACA Inrush current
Check 3 phase sequence.
Sound Level Meters
TES-1350A Sound Level Meter
Features
Range:
A LO (Low) Weighting: 35~100dBA
HI (High) Weighting: 65~130dB
C LO (Low) Weighting: 35~100dB
C HI (High) Weighting: 65~130dB
Frequency: 31.5Hz~8KHz
Dynamic: 65dB
Display: 4 digital
Accuracy: 2dB
TES ELECTRICAL ELECTRONIC CORP.
0.1dB Resolution
Maximum hold function
AUX OUTPUT JACKS
QUALITY & RELIABILITY
41
TES-1351B TES-52S TES-1352S
TES-1351B Sound Level Meter
Features
0.1dB Resolution
Maximum hold function
AUX OUTPUT JACKS
Range:
A LO (Low) Weighting: 35~90dB
A HI (High) Weighting: 65~130dB
C LO (Low) Weighting: 35~90dB
C HI (High) Weighting: 65~130dB
Frequency: 20Hz~8KHz
Dynamic: 65dB
Display: 4 digital
Accuracy: 1.4dB(ref
94dB@1KHz)
IEC 60672
Class 2
TES-52A Sound Level Meter
Features
IEC61672-1 :
2002 Class 2
0.1dB Resolution
60dB Dynamic range
30 to 130dB Measurement
ranges
A&C Frequency weighting
Fast/Slow Time weighting
Maximum/Minimum with
Elapsed time
Measurement frequency range:
31.5 Hz to 8KHz
Measurement level range:
6 ranges in 10-dB step: 25~80dB,
30~90dB,40~100dB, 50~110dB,
60~120dB, 70~130dB
Manual data memory capacity:
99 sets
Manual data memory and read
TES-1352S Programmable Sound Level Meter
Features
TES ELECTRICAL ELECTRONIC CORP.
USB interface
16,000 Records Data logging
42 QUALITY & RELIABILITY
function
Real Time Clock with Calendar
Auto Ranging
IEC 61672-1
Class 2
Frequency: 31.5 HZ~ 8KHz
Level A/C weighting:
30dB~130dB
Six Range:
6 ranges in 10dB step, 30-80dB/
40-90dB/50-100dB/60-110dB/
70-120dB/80-130dB
Auto Range: 30-130dB
Dynamic Range: 50dB
Display: 4 digit LCD
Accuracy: 1.5dB
TES-1353S TES-1354 / 1355 TES-1357
TES-1353S Integrating Sound Level Meter
Features
SPL, Leq, SEL, MaxL, MinL
Wide linearity range of 100dB
32000 Records Data logging
function
USB Interface
Function:
SPL, Leq, SEL, MaxL, MinL
Frequency: 31.5 HZ~8KHz
Level A/C weighting:
30dB~130dB
Display:
4 digit LCD, 0.1dB resolution,
updated every 0.5s
Accuracy: 1.5dB
IEC 61672-1
Class 2
TES-1354/1355 Noise Dosi-Meter
Features
Measures% Noise Dose/
Exposure Time/Sound Level
Real Time Clock with Calendar
RS-232 interface (1355)
Range: 70~140dBA ( 1.5dB)
Digital Display:
0.01~99.99% DOSE
Criterion Level: 80, 84, 85, 90dB
Threshold Level:
70~90dB (1dB step)
Exchange Rate:
3dB, 4dB, 5dB or 6dB
High Level Detector: 115dBA
Peak Flag: 140dB
ANSI S1.25-1978
TES-1357 Precision Sound Level Meter
Features
0.1dB Resolution
Fast/Slow dynamic characteristic
Range from 30~130dB
A&C Frequency Weighting
IEC 60651
Type2
Accuracy: 1.5dB (ref 94dB)
Frequency Weighting: A, C
Measuring Level: 30~130dB
Range:
30~80dB, 50~100dB, 60~110dB,
80~130dB
Frequency: 31.5 Hz~8kHz
TES ELECTRICAL ELECTRONIC CORP.
QUALITY & RELIABILITY
43
TES-1358C TES-1358E TES-1359
TES-1358C Sound Analyzer
Features
For Delicate Sound Improvement
(Sound Effect/Sound
Environment)
Compliant with IEC 61672-1 class
2 standard
Real Time 1/1 (11 bands) & 1/3
(33 bands) octave analysis
Measurement can be started by
internal or external trigger.
Data transfer using USB
Dynamic range of 90dB
Real time clock with calendar
AC and DC output
Display: TFT-LCD color display
Range: 30dB to 130dB
Function: Lp, Leq, LE, Lmax, Lmin
Frequency: 12.5Hz to 20KHz
Frequency Weighting: A, C and Z
Time Weighting: Fast, Slow
1/1-1/3 Analyzer level range:
5 ranges in 10dB step, 40-130dB / 30120dB / 20-110dB / 10-100dB / 0-90dB
Memory Capacity: 10,000 data (Sound
level mode)
TES-1358E Sound Analyzer
Features
For Delicate Sound Improvement
(Sound Effect/Sound
Environment)
Compliant with IEC 61672-1 class
1 standard
Real Time 1/1 (11 bands) & 1/3
(33 bands) octave analysis
Measurement can be started by
internal or external trigger.
Comparator output to trigger
external devices
Data transfer using USB
Dynamic range of 90dB
AC and DC output
Micro SD Card 4GB
Display: Super high-contrast
backlight TFT-LCD color display
Range: 30dB to 130dB
Function: Lp, Leq, LE, Lmax,
Lmin, L05, L10, L50, L90, L95
Frequency: 12.5Hz to 20KHz
Frequency Weighting: A, C and Z
Time Weighting: Fast, Slow,
=10ms, Impulse
Measurement level range: 5
ranges, 20-90dB / 20-100dB, 20110dB / 30-120dB / 40-130dB
Memory Capacity: Manual 250
data sets, Auto 250 blocks on
micro SD CARD 4GB
TES-1359 Sound Level Meter
TES ELECTRICAL ELECTRONIC CORP.
Features
44 QUALITY & RELIABILITY
IEC 61672-1
Complies with IEC 61672-1 standard
Dynamic range: 60dB
Five ranges (30 to 130 dB)
A&C Frequency weighting
Fast / Slow time weighting
Maximum hold
Accuracy: 1.4dB@1KHz
Measurement Level: 30dB to 130dB
5 ranges in 10 dB step: 30~ 90dB,
40 ~ 100dB, 50 ~ 110dB, 60 ~ 120dB, 70 ~ 130dB
Linearity range: 60dB
Frequency: 31.5Hz to 8KHz
Frequency weight: A and C
Time weight: Fast and Slow
Display Warning function:Overrange Indicator: Displayed at the upper limit
Underrange indicator:Displayed at the lower limit
Analog AC/DC output: 1Vrms (at full scale), 10mVDC/dB
RM-1000 RM-1500 / 1501 TES-1300 / 1303
Tachometer
RM-1000 Digital Optical Tachometer
Features
Range: 10.0-100,000RPM
Direct Light-Beam Sensing
Memory Recall/Data Hold
5 digits LCD display
Auto range
Sampling rate: 1 sec.( 60 rpm)
1 sec.(10~60 rpm)
Accuracy: 0.01% 1dgts
Resolution: 0.1/1/10 RPM
Measuring Distance:
50mm~300mm
Max distance: 300mm
MAX/ MIN/STAND-BY
Data Hold
Time Base: 12.0MHz Quartz
Crystal
RM-1500/1501 Digital Tachometer
RM-1502
Features
Speed (Non-contact)
RPM: 10~99,990
rps (Hz): 0.2000~2,000.0
5 Digits LCD Display
Auto Range
Measuring Distance 50~300 mm
Combination for non-contact &
contact measurements
RS-232 (RM-1501)
Resolution(Non-Contact): 0.01/
0.1/1rpm
Max / Min / Hold, True Average
Sampling time:
0.7 sec.( 60 rpm),
1 sec.(10~60 rpm)
Speed (Contace)
10.000~29,999RPM
Event Counter
0-99999
Optional Accessory:
RM-1502, Contact Adaptor
Thermometers
TES-1300/1303 Thermometer
Features
Range:-50~1300/-50~1,999
Sensor: K Type thermocouple
Input: Single (1300), Dual (1303)
Display: 3-1/2 digit LCD
Resolution:0.1 TES ELECTRICAL ELECTRONIC CORP.
Max Hold Function
Data Hold Function
Aux output JACKS
T1-T2 differential measurement
QUALITY & RELIABILITY
45
TES-1304 TES-1306 TES-1307
TES-1304 Printing Thermometer
Features
Type K.J.E.T. Thermocouple Input
Dual Channels withmultifunctions
(T1, T2 & T1-T2)
Built-in thermo printer with
programmable Time interval setting
Range:
Type K: -200~1333(-328~2431)
Type J: -200~760(-328~1400)
Type E: -200~703(-328~1297)
Type T: -200~400(-328~752)
Display: 4 1/2 LCD Digital Display
TES-1306 K/J Thermometer
Features
K/J Type thermocouple input
Auto ranging
Data Hold
Maximum/Minimum reading
Multi-channels scanner
Range:
Type K: -200~1370/-328~2498
Type J: -200~760/ -328~1400
Sensor: K/J Type thermocouple
Display: 3-1/2 digit LCD
(T1 T2 T1-T2)
TES-1307 Datalogging K/J Thermometer
TES ELECTRICAL ELECTRONIC CORP.
Features
46 QUALITY & RELIABILITY
K/J Type thermocouple input
Auto ranging/Data Hold
15,000 Record Data logging Capacity
Maximum/Minimum/Average reading
RS-232 Interface (Software Include)
Dual display LCD with Clock
Range:
Type K: -190~1333/ -310~2431
Type J: -190~760/ -310~1400
Resolution:
0.1 for -190~1000
1 for 1000~1333
Condition:
0~40 below 80% R.H.
-10~60 below 70% R.H.
TES-1311A TES-1312A TES-1314
TES-1311A Thermometer
Features
Switchable Resolution 0.1 /1.0 With & switching
Data Hold Function
Room Temperature compensated
Data Memory 150 readings
(Memory/Read)
Range: ( 0.1%rdg 1/2)
-50~1,300/-58~1,999
Sensor: K Type thermocouple
Input: Single
Sampling Rate: 2.5 times/sec.
Resolution: -50~199.9:0.1
-59~199.9:0.1
Others:1/1
TES-1312A Triple Display Thermometer
Features
Type "K" thermocouple input
Autorange resolution 0.1 /1 With , & K switching
Offset (Relative) /Data Hold Function
MAX/MIN/AVG with elapse time function
Room Temperature compensated
T1 & T2 dual points display
T1-T2 differential measurement
Backlight Large LCD display
Range: -200~1,370/-328~1,999
Resolution:-200~199.9:0.1
-328~199.9:0.1
Others:1/1
Accuracy:-200~1,000 (-328~1832): (0.3%rdg+1/2)
1,000~1370 (1832~1,999): (0.5%rdg+1/2)
Sampling Rate: 2.5 times/sec.
TES-1314 K, J, E, T, R, S, N Thermometer
Features
High accuracy with K, J, E, T, R,
S, N type
setting
MAX/MIN with TIME, MAX-MIN,
AVG, HOLD
//K User-Selective
Back-Light LCD display
TES ELECTRICAL ELECTRONIC CORP.
Dual input, T1/T2 temp. display
Warning beeper with HI/LO
Range:
K: -150.0~+1,372.0(-200.0~+2,501.0)
J: -150.0~+1,090.0(-200.0~+1994.0)
E: -150.0~+870.0(-200.0~+1598.0)
T: -150.0~+400(-200.0~+752.0)
R,S: 2.0~+1767.0(+35.0~+1999.9)
N: -150.0~+1300.0(-200.0~+1999.9)
Resolution:
J, K, T, E and N Type: 0.1//K
R and S Type: 1.0//K 200 Sampling Rate: One time per 1.5 sec.
QUALITY & RELIABILITY
47
TES-1315 / 1316 TES-1317 / 1317R TES-1318
TES-1315/1316 Datalogging Thermometer K, J, E, T, R, S, N
Features
High accuracy with K, J, E, T, R,
S, N type
Dual input, T1/T2 temp. display.
(1316)
7,500 Datalogging capacity
Warning beeper with HI/LO
setting
MAX/MIN with TIME, MAX-MIN,
AVG, HOLD
//K User-Selective
Back-Light LCD display
Range:
K: -150.0~+1,372.0(-200.0~+2,501.0)
J: -150.0~ +1,090.0(-200.0~+1994.0)
E: -150.0~+870.0(-200.0~+1598.0)
T: -150.0~+400(-200.0~+752.0)
R,S: 2.0~+1767.0(+35.0~+1999.9)
N: -150.0~+1300.0(-200.0~+1999.9)
Resolution:
J, K, T, E and N Type: 0.1//K
R and S Type: 1.0//K 200 Sampling Rate: One time per 1.5 sec.
TES-1317/1317R Platinum RTD Thermometer
Features
Pt 3916/3926/385 RTD standard
Stand-alone logging function 97
sets
4,200 Datalogging capacity
(1317R)
Warning beeper with HI/LO
setting
Time setting
MAX/MIN with TIME, MAX-MIN,
AVG Hold
//K User-Selective
Back-Light LCD display
RS-232 (TES-1317R)
Range:
( 0.05 % rdg 0.5/0.9)
-190~790 (-310~1454)
Resolution: 0.1/0.1/0.1K
Sampling Rate: 1.5 time/sec.
TES-1318 Platinum RTD Thermometer (Dual Channels)
Features
TES ELECTRICAL ELECTRONIC CORP.
Pt 3916/3926/385 RTD standard
Stand-alone logging function
48 QUALITY & RELIABILITY
40 sets
Warning beeper with HI/LO
setting
Time setting
MAX/MIN with TIME, MAX-MIN,
AVG Hold
//K User-Selective
Back-Light LCD display
Range:
( 0.05 %rdg 0.5/0.9)
Pt385: -190~790 (-310~1454)
Pt3916: -190~615 (-310~1139)
Pt3926: -190~615 (-310~1139)
Resolution: 0.1/0.1/0.1K
Sampling Rate: One time per 1.5 sec.
TES-1319A TES-1384 TES-1326S / 1327 / 1327K
TES-1319A Thermometer (Type K)
Features
Switchable Resolution 0.1 /1 With & switching
Data Hold Function
Memory/Read function
Filp-up stand
Range:
-50~1300, -58~1999
Resolution:
-50~199.90.1
-59~199.9 0.1
Others1/1
Accuracy:
-50~0 (-58~0):(0.5%+1/2)
0~1,000(0~1832):(0.3%+1/2)
1,000~1,300(1,832~1,999):
(0.5%+1/2)
Sampling: 2.5 times/sec.
TES-1384 4 Channels Thermometer / Datalogger
Features
Isolated Input Protection of
350Vp-p between any two inputs
0.05% Accuracy.
K, J, E, T, R, S, N, L, U, B, C
Thermocouple Input
Display T1, T2, T3 & T4
Simultaneously
Independent Input Setup (type of
thermocouple, Hi-Lo alarm
values)
Data Memory and Read function
(99 sets)
Datalogging Capacity (512 KB)
Software with USB cable
Programmable Hi-Lo alarm for 4
inputs
MAX, MIN, Max-Min & AVG
values
TES-1326S/1327/1327K Infrared / K Type Thermometer
Features
/ Selectable / 0.1 / 0.2 Reso-
lution
Built-in Laser Sighting / Backlight
Display: Backlight LCD display
Measurement Range: -35 ~ 500
(-31 ~ 932)
Resolution: 0.1 / 0.2
Accuracy: 2% reading or 2
Spectral Response: 6 ~ 14 m
Field of View: 12:1 optics ratio with
a 1min target
Emissivity: 0.17 ~ 1.00 (1326S :
fixed 0.95)
Sighting: Laser marker < 1mw
K-Type Thermometer (TES-1327K)
Measurement Range : -150 ~ 1350 (-238 ~ 1999)
Resolution : 0.1 / 1 0.1 / 1
Function
Resolution
Range
Accuracy
0.1
-150 ~ 0
(0.2% rdg + 1.0)
0 ~ 200
(0.1% rdg + 1.0)
1
200 ~ 1350
(0.2% rdg + 2)
0.1
-238 ~ 32
(0.2% rdg + 2)
32 ~ 200
(0.1% rdg + 2)
1
200 ~ 1999
(0.2% rdg + 4)
TES ELECTRICAL ELECTRONIC CORP.
LCD display
Auto Power off (approx. 15 sec.)
Laser targeting.
Maximum / Minimum function.
Data memory and read function. (50
readings)
Emissivity adjustable. (1327/1327K)
Audible and visible alarm. (1327/
1327K)
Dual thermometer and Dual display.
(1327K)
Infrared Thermometer
QUALITY & RELIABILITY
49
TES-1327KUSB VT-01 Prova 400
TES-1327K-USB IR Thermometer
Features
K-Type Thermometer
Measurement Range : -150 ~ 1350
(-238 ~ 1999)
Resolution : 0.1 / 1 0.1 / 1
Infrared Thermometer
Dual Thermometer and Dual display.
USB Interface / Software
Datalogging Capacity 21,000 set
Emissivity adjustable.
/ Selectable / 0.1 / 0.2
Resolution
Built-in Laser Sighting / Backlight
LCD display
Laser targeting.
Maximum / Minimum function.
Data memory and read function. (99
readings)
Audible and visible alarm.
Function
Resolution
0.1
1
0.1
1
Display: Backlight LCD display
Measurement Range: -35 ~ 500
(-31 ~ 932)
Resolution: 0.1 / 0.2
Accuracy: 2% reading or 2
Spectral Response: 6 ~ 14 m
Field of View: 12:1 optics ratio with
a 1min target
Emissivity: 0.17 ~ 1.00
Sighting: Laser marker < 1mw
Range
-150 ~ 0
0 ~ 200
200 ~ 1350
-238 ~ 32
32 ~ 200
200 ~ 1999
Accuracy
(0.2% rdg + 1.0)
(0.1% rdg + 1.0)
(0.2% rdg + 2)
(0.2% rdg + 2)
(0.1% rdg + 2)
(0.2% rdg + 4)
Transformation Device
VT-01 Transformation Device
Features
Display Measurement Reading on
the LCD panel without Personal
Computer
Easy, Simple and cost effective
Public information display from
measuring instrument
Specifications
Input: RS-232 serial port (Male)
Output: VGA display port
AC Adapter: 5V, 2.5A
Idea for
CO2 Meter
Temperature Humidity Meter
Sound Level Meter
TES ELECTRICAL ELECTRONIC CORP.
Watt Clamp Meter
Prova 400 AC/DC TRMS WATT Clamp Meter
Features:
Relative Measurement
True Power, AC 240KW, DC 240KW
AC/DC Power: 40/240 KW
True RMS ACA 400A, ACV 600V
AC Voltage: 600 V
DCA 400A, DCV 400V
DC Voltage: 400 V
Large 3 3/4 digits LCD(4032 counts)
Frequency: 1~100KHz
Fast Bargraph Display (30times/sec.)
23mm Jaw diameter
Max/Min, Date Hold
One touch zero for DAC, DCW
IEC 1010
CAT 300V
CAT 600V
50 QUALITY & RELIABILITY
Optional Accessories
Optional Accessories:
Model No.
Description
BS4
pH4 Buffer Solution for TES-1380
BS7
pH7 Buffer Solution for TES-1380
CS-150
Conductivity probe for TES-1381
PAPER 300XP
Replacement Paper, 10 rolls/box for Prova 300XP / 310XP
PH-200
pH Electrode for TES-1380
PT-100
Temperature Probe for TES-1380
PT-100A
RTD Probe for TES-1317, TES-1318
RFT-01
Reflective Tape for RM-1000, RM-1500, RM-1501
RID45-234
Cable Remote Identifier Kit for TES-45, #2, #3, #4
RID45-5678
Cable Remote Identifier Kit for TES-45, #5, #6, #7, #8
RID46-234
Cable Remote Identifier Kit for TES-46, #2, #3, #4
RID46-5678
Cable Remote Identifier Kit for TES-46, #5, #6, #7, #8
RM-1502
Contact Adaptor for RM-1500, RM-1501
SOLAR 15
DC Probe for Prova 1011
SOLAR 21
AC Clamp for Prova 1011
TES-3092CP
DCA Current Adaptor for TES-33
TES-3620-2
Test Leads for TES-33
TES-3620-3
Test Leads for TES-33, Alligator Type
THP-38
Thermo Paper for TES-1304, TES-1362
TL-088-1
Test Lead for TES-3063
TL-700 CLIP
Alligator Clip for Prova 700 / 710 / 200A / 210 / 218
TL-200 KELVIN CLIP
Kelvin Clips for Prova 200A / 210 / 218
TL-700 KELVIN CLIP
Kelvin Clips for Prova 700 / 710
TL-700 SPRING LEADS 4-Wire double prod Test Leads for Prova 700 / 710
TL-B15-1 (90 )
Test Lead for TES-2620, TES-2700, TES-2712, TES-2730, TES-2732A
TL-B15-1 (180 )
Test Lead for TES-3010, TES-3012
TL-B25-1
Test Lead for TES-1500
TL-D36
Test Lead for TES-1600
TL-E33
Test Lead for TES-3660, TES-3663
TL-E45-1
Test Lead for TES-1601, TES-1604
TL-E53
Test Lead for TES-1800
TL-E57-1
Test Lead for TES-3040, TES-3050, TES-3074, TES-3079M, TES-3082, TES-3091N,
TES-3092, TES-3095T, TES-3096T
TL-E61
Test Lead for TES-32
TL-F47A
Microphone Extension Cable (5M)
TL-F47B
Microphone Extension Cable (10M)
TL-F54
Test Lead for TES-1605, TES-1700
Temperature Bead Probe
TP-K02
Temperature Immersion Probe
TP-K03
Temperature Surface Probe
TES ELECTRICAL ELECTRONIC CORP.
TP-K01
QUALITY & RELIABILITY
51
Distributed by :
Specification changes subject without notice.
2015 / 09 printed
Download PDF