5531
Loop-powered LCD indicator
∙ 4 digit 1/8 DIN (48 x 96 mm) loop-powered LCD display
∙ Easy push-button configuration
∙ Backlit LCD display is readable in low light conditions
∙ Display can be mounted in the safe or Ex area
∙ Available with the 8501 field enclosure
Application
•The 5531 indicator is powered by the 4 to 20 mA
current loop and is easily scaled to display the
correct process value.
•Because it does not require separate power wiring,
the 5531 is perfect for remote display of process
loops.
•The 5531A display can be panel mounted in the
safe area or Ex Zone 2 (gas).
•The 5531B1 Ex display includes the 8501 enclosure
and can be mounted in Ex Zone 2 or 22 (gas or
dust).
•The 5531B2 includes the 8501 enclosure, and can
be mounted in Ex Zone 1, 2, 21 or 22 (gas or dust).
Technical characteristics
•With a full measurement range of 3.6 to 23 mA, the
5531 is NAMUR NE43 compliant.
•The display can be push-button scaled to any range
between -9999 to 9999, and reverse display action
is possible.
•The LCD backlight can be set to half or full intensity
for easy viewing in low light conditions.
•The display only requires 1.5 VDC, (75 Ω loop load),
with the backlight turned off.
•The input is HART® transparent.
•The front push-buttons can be disabled to prevent
unauthorized adjustment.
Mounting / installation
•Once panel mounted with the included gasket, the
5531 provides IP65 ingress protection.
ConnectionS
Input signal:
www.prelectronics.com
4...20 mA
4
3
2+
1-
e
Ordering codes for 5531:
Type
Accessories:
Version
Field enclosure
Type
Specification
5531A
Standard, Zone 2
No
8335
Splash proof cover
5531B1
Standard, Zone 2, 22
Yes
8501
Field enclosure for 5531A
5531B
Ex Zone 0
No
5531B2
Ex Zone 0, 20
Yes
Environmental conditions:
Approvals:
Specifications range..................................
Storage temperature.................................
Calibration temperature.............................
Relative humidity.......................................
Protection degree, from front....................
-20°C to +60°C
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP65
EMC 2004/108/EC.................................... EN 61326-1
GOST R
Ex:
Mechanical specifications:
Dimensions (HxWxD), 5531A, 5531B........
Cut-out dimensions (HxW)........................
Weight approx., 5531A, 5531B.................
Dimensions (HxWxD), 5531B1, 5531B2....
Cable glands and cable diameter.............
Dimensions, 8501 backplate.....................
Weight approx., 5531B1, 5531B2.............
Wire size, connector terminal 1 - 4............
48 x 96 x 120 mm
44.5 x 91.5 mm
200 g
92 x 112 x 143 mm
2x M16
112 x 112 mm
900 g
0.13...2.08 mm2 /
AWG 26...14 stranded wire
Screw terminal torque............................... 0.5 Nm
Common electrical specifications:
Supply.......................................................
Signal / noise ratio.....................................
Response time (0...90%, 100...10%)........
Updating time............................................
Ex data:
Ui...............................................................
Ii ...............................................................
Pi...............................................................
Ci...............................................................
Li...............................................................
: 45 VDC
: 120 mA
: 0.9 W
: 0 nF
: 0 mH
8501 field enclosure:
The field enclosure type 8501 complies with industrial standards for
efficient protection of process equipment in wet areas up to IP65.
When 8501 is delivered with a built-in PReview 5531, the assembled
unit is approved for installation in explosive gas atmospheres as well
as in explosive dust environments. The technical specifications of the
field enclosure can be found in the 8501 data sheet.
Input loop-powered
> 60 dB
<1s
500 ms
Input and output specifications:
Input range................................................
Measurement range..................................
Input voltage drop, without backlight........
Input voltage drop, with full backlight.......
Loop error detection, 4...20 mA:
Low detection (InLo) ..............................
High detection (InHi) ..............................
Display readout.........................................
Digit height................................................
ATEX 94/9/EC, 5531A and 5531B1........... KEMA 05ATEX1044 X
ATEX 94/9/EC, 5531B and 5531B2........... KEMA 05ATEX1105 X
IECEx......................................................... Pending
GOST Ex (5531B)
4...20 mA
3.6...23 mA
< 1.5 V @ 20 mA
< 10.5 V @ 20 mA
~ < 3 mA
~ > 24 mA
± 9999 (4 digits)
16 mm
Accuracy values
Input
Absolute
accuracy
Temperature
coefficient
4...20 mA
≤ ±0.1% of span
≤ ±0.01% of span / °C
EMC immunity influence................................... < ±0.5% of span
Routing diagram:
DP SW 1 must be ON to enable front buttons.
If no buttons are pressed for a period of 2 minutes,
display returns to stage 0.0
To store changes press
simultaneously.
Power on
Programming:
DP 1 Front keyboard
Display type no. is shown
0.0
SW ON
SW OFF
Keys locked
-
1
Keys NOT locked
1
-
SW ON
SW OFF
Off
2
-
Half intensity
3
2
Full intensity
-
2, 3
DP 1 Backlight
1.3
5531Y105-UK (1302)
DIP-switch is located on the rear.
N
G
1.2
N
DI
1.1
PE
1.0
Download PDF