Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
PRODUCTS AND SERVICES CATALOGUE
Contents
1 POWER QUALITY ANALYSERS ...................................................................................... 4
1.1 GRIDSENSE POWERMONIC ............................................................................. 4
1.1.1 Introduction ......................................................................................................... 4
1.1.2 Key Features ...................................................................................................... 4
1.1.3 Current Sensor Options...................................................................................... 5
1.1.4 Specifications ..................................................................................................... 5
1.2 SUIN SA2100 ...................................................................................................... 7
1.2.1 Introduction ......................................................................................................... 7
1.2.2 Key Features ...................................................................................................... 7
1.2.3 Current Sensor Options...................................................................................... 7
1.2.4 Voltage Leads .................................................................................................... 9
1.2.5 Flexible Current Probe ..................................................................................... 10
1.2.6 Carry Bag ......................................................................................................... 10
1.2.7 Kit Items............................................................................................................ 10
1.2.8 Specifications ................................................................................................... 11
1.3 ZES ZIMMER LMG500 ...................................................................................... 13
1.3.1 Introduction ....................................................................................................... 13
1.3.2 Key Features .................................................................................................... 13
1.3.3 Device Interface ............................................................................................... 14
1.3.4 Connections ..................................................................................................... 15
2 LOGGING INSTRUMENTS ............................................................................................. 16
2.1 LOAD LOGGER ................................................................................................ 16
2.1.1 Introduction ....................................................................................................... 16
2.1.2 Feature summary ............................................................................................. 16
2.1.3 Kit ..................................................................................................................... 17
2.1.4 Accessories ...................................................................................................... 17
2.1.5 Options ............................................................................................................. 18
2.1.6 Specifications ................................................................................................... 18
3 REMOTE (ONLINE) MONITORING SYSTEMS ............................................................... 20
3.1 LOAD REMOTE ................................................................................................ 20
3.2 MONITORING BACK-UP GENERATORS ......................................................... 21
3.2.1 G8500 SINGLE GENERATOR SYSTEM ......................................................... 22
3.2.2 G8600 MULTIPLE GENERATOR SYSTEM .................................................... 23
3.2.3 G8700 MOBILE GENERATOR SYSTEM ........................................................ 24
3.2.4 G8800 RESIDENTIAL GENERATOR SYSTEM .............................................. 25
4 CURRENT PROBES AND SENSORS............................................................................. 26
4.1 FLEXIBLE CURRENT SENSORS ..................................................................... 26
4.2 CLAMP ON CURRENT SENSORS ................................................................... 28
4.3 MINIATURE SPLIT-CORE CURRENT TRANSFORMERS ................................ 30
4.3.1 Key Features and General Specifications ........................................................ 30
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 1
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
4.3.2 Range ............................................................................................................... 30
4.4 SUBSTATION CURRENT TRANSFORMER CONVERTERS............................ 31
4.4.1 Introduction ....................................................................................................... 31
4.4.2 Specifications ................................................................................................... 31
5 INSTRUMENT CURRENT TRANSFORMERS ................................................................ 32
5.1 METERING ....................................................................................................... 33
5.1.1 Measuring - PVC .............................................................................................. 33
5.1.2 Measuring - MBQ Series .................................................................................. 34
5.1.3 Measuring - MSQ Series .................................................................................. 35
5.1.4 Measuring - Tape Insulated Ring Type - KTM Series ...................................... 37
5.1.5 Measuring - Resin Cast Ring Type - KRM Series ............................................ 40
5.1.6 Measuring - Resin Cast Ring Type - KSM Series ............................................ 42
5.2 PROTECTION ................................................................................................... 44
5.2.1 Protection - PVC ............................................................................................... 44
5.2.2 Protection - Tape Insulated Ring Type - KTP Series ....................................... 45
5.2.3 Protection - Resin Cast Ring Type - KRP Series ............................................. 47
5.2.4 Protection - Resin Cast Ring Type - KSP Series ............................................. 49
5.3 SPECIAL PURPOSE ......................................................................................... 50
5.3.1 Summation Current Transformer ..................................................................... 50
5.3.2 Interposing Current Transformer ...................................................................... 50
5.3.3 Core Balance Current Transformer .................................................................. 51
6 MEDIUM VOLTAGE PRODUCTS ................................................................................... 52
6.1 MONITORING PRODUCTS .............................................................................. 52
6.1.1 Cable Mounted Sensor..................................................................................... 52
6.1.2 Pole Mounted Sensor ....................................................................................... 53
6.2 INDOOR AND OUTDOOR VOLTAGE TRANSFORMERS ................................ 55
6.2.1 Indoor Single Phase Single Pole Voltage Transformers .................................. 55
6.2.2 Indoor Single Phase Double Pole Voltage and Control Transformers ............. 56
6.2.3 Indoor Voltage Three Phase Voltage Transformers ........................................ 57
6.2.4 Draw-Out Voltage Transformers ...................................................................... 59
6.2.5 Outdoor Voltage and Control Transformers ..................................................... 59
6.2.6 Outdoor Metering Units .................................................................................... 60
6.3 INDOOR AND OUTDOOR CURRENT TRANSFORMERS ................................ 60
6.3.1 Indoor Ring Type, Window Type and Bus Duct (up to 36kV) .......................... 60
6.3.2 Indoor Bar Primary Current Transformers (up to 36kV) ................................... 61
6.3.3 Indoor Wound Primary (block Type) Current Transformers (up to 36kV) ........ 62
6.3.4 Outdoor Current Transformers ......................................................................... 63
7 POWER QUALITY MITIGATION PRODUCTS ................................................................ 64
7.1 REACTORS AND FILTERS............................................................................... 64
7.2 POWER FACTOR CORRECTION UNITS ......................................................... 64
7.3 ACTIVE HARMONIC FILTERING ...................................................................... 65
8 CONSULTING AND SERVICES ...................................................................................... 67
8.1 CONSULTING IN POWER QUALITY ................................................................ 67
8.1.1 Power Quality Investigation .............................................................................. 67
8.1.2 Power Quality Mitigation ................................................................................... 67
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 2
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
8.1.3 Power Quality Management ............................................................................. 67
8.2 TRAINING ......................................................................................................... 67
8.2.1 Product Training ............................................................................................... 67
8.2.2 Professional Training ........................................................................................ 67
8.3 TECHNICAL SUPPORT .................................................................................... 67
8.3.1 Product Support ............................................................................................... 67
8.3.2 Calibration and Repairs .................................................................................... 67
8.4 LOW VOLUME CONTRACT MANUFACTURING .............................................. 68
8.5 ENGINEERING AND PROJECT MANAGEMENT SERVICES .......................... 68
8.5.1 Feature Requests and New Features .............................................................. 68
8.5.2 Design .............................................................................................................. 68
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 3
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1 Power Quality Analysers
1.1 GridSense Powermonic
1.1.1 Introduction
The PowerMonic range of portable power recorders offers comprehensive and reliable
monitoring of low voltage circuits. Built with high performance, toughness and focus on ease
of use, the PowerMonic has been adopted as the workhorse instrument for a variety of
power monitoring applications including power quality analysis, supply compliance checks,
power flow studies, energy audits and voltage investigations. The PM45 is the latest addition
to the PowerMonic product line, meeting CATIV-600V safety certification and voltage
measurement standards. With four voltage and current channels, the PM45 records a trend
over time along with a range of power quality parameters, including flicker, harmonics, power
and imbalance in accordance to the latest IEC standards.
The PM45 is also an independent event recorder capturing high resolution snapshots of
fluctuations including motor starts, spikes and transients based on voltage and current limit
settings. Utilized for short and long term power monitoring applications, the PM45 is typically
installed on pad mount and pole mount transformers, capacitor banks, regulators,
distribution substations, as well as commercial, residential and industrial connection points.
Since its introduction in 1995, the PowerMonic has proven to be a reliable and versatile
everyday instrument used worldwide by System Planners, Distribution Engineers, Electrical
Engineers, Electrical Contractors, Power Quality Engineers, and Maintenance Engineers
alike.
1.1.2 Key Features



Up to eight (8) input channels [four (4) voltage and four (4) current]
Power profiling with high-speed event capture
Transient and harmonic analysis, flicker and unbalance
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 4
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au









Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Graphical LCD for measurements and recording status
Power directly from A phase - external power not required
Double insulated and fused voltage cables
Auto-scaling current transformer connection
Data download and firmware upgrade via USB
CAT IV 600V safety rating (PM45) and certified to IEC 61010
AS60529-2004 IP66 (PM45) and IP65 (PM35) protection
Wide operating temperature range: -20°C to 70°C
Wireless remote communications option available
1.1.3 Current Sensor Options
Refer to sections 4.1 and 4.2.
1.1.4 Specifications
PARAMETER
Measurement
PM45
PARAMETER
General
Samples per cycle
204 @ 50Hz; 170@ 60Hz
Input Cannels
Sample Rate
PPL Synchronised (IEC
61000-4-7).
Measurement Range
Memory
15MB internal flash
Input Range
Power Meter
V, A, Min, Max, Freq,TPF,
DPF, KW, KVA, KVAR
Instrument Accuracy
Total Harmonic
Distortion
IEC 61000-4-7 (THD-F &
THD-R)
System Accuracy
IEC 61000-4-7 (up to 48th
Magnitude and Angle)
IEC 61000-4-7 (up to 48th)
IEC 61000-4-15 (10min.
Pst & 2hr. Plt)
Resolution Logged
Data
Resolution LCD
Voltage and
Current Unbalance
IEC 61000-4-30
Circuit connections
Instrument Type
Class B (IEC 61000-4-30)
Current Probe
Options
Frequency Range
50Hz nom. (42.5-57.5) Hz
60Hz nom. (51.0-69.0) Hz
Communications
Harmonics
Interharmonics
Flicker (Pst & Plt)
High Speed Event
Recording
Table Capture
(Sags/Swells)
User defined Rolling
and/or Threshold Voltage
and Current & Transient
Triggers
Half Cycle, Min/Max &
Duration
PM45
4 isolated voltage channels;
4 current channels
A, B & c channels: 0600VAC; Vgnd 0 - 60 VAC
(±1% reading ±1 lsd); 03000A
Voltage: 0-600VAC (660VAC
absolute);
Current: 0-440mV at 10k
Ohms
0.4% readings + 1 lsd
(current and voltage)
Voltage: 0.4% readings + 1
lsd; Current: 1% readings + 1
lsd
0.001V; 0.001A
0.1V; 0.1A
Three Phase Wye/Delta,
Open/2-Element Delta, Split
Phase & Single Phase
C10* (0-10A), C100S* (10125A), C500* (25-600A),
Flexi F3000-6 (150-3600A) *
Not CATIV-600V Rated
Direct Connection:
USB Serial Cable; Remote
Connection: Cellular
(GPRS/3G/CDMA)
Mechanical & Power
Power Source - Main
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
60-600VAC from Phase A,
and USB powered for
Page 5
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
configuration and
downloading
RMS Snapshot
Waveform
Snapshot
Half Cycle, 5s - 30s
duration
Sample rate for 400ms
duration
Power Source backup
Non-rechargeable batteries
Power Consumption
10W typical (from Phase A)
Display
Environmental &
Safety
Temperature
Range
Humidity
Protection Class
Protection levels
Real-Time-Clock
-20°C (-4°F) to +60°C
(+130°F)
20%-99% Relative
Humidity
IP66 (all weather housing)
IEC 61010-1 2001;
Pollution degree 3;
Measurement Category IV
- 600V
Dimensions
Weight
Graphic LCD 128 x 64 bits
(0.1 resolution)
3V 950mAh Li-Magnanese
Dioxide/Organic Electrolyte
230mm/9.1” (l) x
120mm/4.72” (w) x
90mm/3.6” (d)
7lbs (3kg) instrument only
PM35 specifications are similar to the above with the following changes:
 Protection Class: IP65;
 Voltage lead connector is CAT III 600V;
 No inter-harmonics.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 6
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1.2 SUIN SA2100
1.2.1 Introduction
The SUIN SA2100 is a comprehensive and cost effective instrument ideally suited for the
electrical trades toolbox and intended to monitor your electrical supply and diagnose Power
Quality issues on-site and in real-time. It is battery operated and therefore offers the
flexibility of a handheld multi-meter.
1.2.2 Key Features








Safety: CAT III 1000V / CAT IV 600V
Standards: IEC61000-4-30 (2008) S class EN50160 (2007)
Single-phase 2 W / Single-phase 3 W / 3-phase 3 W / 3-phase 4 W
Monitors four (4) voltages and currents
Display: Run Chart, Bar Chart, Vector Graphic, Waveform, Event List, Readings
Harmonics and interharmonics, flicker, transient capture, three-phase unbalance (voltage
and current), dips and swells, voltage rapid change, and interruption
LAN interface PC can keep real-time remote communication
Built-in 8G memory card, USB port, LAN port for real-time remote control functionality
and data download
1.2.3 Current Sensor Options
Description
Part Number
5A Clamp-On CT
50A Clamp-On CT
100A Clamp-On CT
1000A Clamp-On CT
3000A Flexible Rogowski Coil
SUC8C-5A
SUCTC0080
SUCTC0130
SUCTC1535
SUJK-3000A
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 7
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
SUC8C-5A
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
SUCTC0080
SUCTC1535
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
SUCTC0130
SUJK-3000A
Page 8
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1.2.4 Voltage Leads
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 9
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1.2.5 Flexible Current Probe
1.2.6 Carry Bag
1.2.7 Kit Items
Description
SA2100 Power Quality Analyser
Program Software for PC (CD)
2m voltage cable with 4mm banana plug
Alligator Clips
External DC Power Adaptor
External DC Adaptor
Carry Bag
Hang Strap
Current Sensors
Part Number
Quantity
SU2100PQA
SU2100CD
SU2100VL
SU2100CC
SU2100PA
SU2100PC
SU2100BAG
SU2100HS
1
1
5
5
1
1
1
1
4 (select option)
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 10
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1.2.8 Specifications
Measurement Range
Resolution
Accuracy
Voltage/Current/Frequency
Channel
3-phase line input + 1 neutral line input
Vrms(dc+ac)
1 ~ 1000Vrms
0.1Vrms
±5%
Vpk
1 ~ 1400Vpk
0.1Vpk
±5%
V(CF)
1.0 ~ >2.8
0.01
±5%
1~ 3000A
1A
±1% ± 5digits
Arms
1~ 300A
0.1A
±1% ± 5digits
Apk
1 ~ 4000Apk
1A
±1% ± 5digits
A(CF)
1 ~ 10
0.01
±5%
42.5~57.5Hz(50Hz nominal) 0.01Hz
±0.01%
Frequency
51~69Hz(60Hz nominal)
0.01Hz
±0.01%
Dips & Swells
0 ~ 200% of nominal
Vrms1/2
0.1Vrms
±1%
voltage
Arms1/2
1 ~ 3000A
1A
±1% ±5 counts
1 ~ 300A
0.1A
±1% ±5 counts
Threshold levels
Programmable thresholds in percent of nominal voltage
Event detection based upon ½ cycle rms voltages
Captures Dips, Swells Interruptions and Rapid Voltage Changes
Duration
Harmonic
Harmonic Order
Inter-Harmonic Order
Voltage
Current
THD
DC Relative
Frequency
Phase
Power And Energy
Active Power/Apparent
Power/Reactive Power
hhh,mm,ss,mmm
0.5 cycle
1 cycle
0.0 ~ 100.0%
0.0 ~ 100.0%
0.0 ~ 100.0%
0 ~ 3500Hz
-360° ~ 0°
0.1%
0.1%
0.1%
0.1%
1Hz
1°
±0.1% ± nx0.1%
±0.1% ± nx0.1%
±2.5%
±2%
1Hz
± nx1.5°
1.0 ~ 20.00MW
0.1kW
±1.5±10 counts
Energy
Power Factor
Flicker
Pst(1min),Pst,Plt,PF5
Unbalance
Voltage
Current
Voltage Phase Angle
Current Phase Angle
Voltage Transient
Vpk
Vrms
Min. Tested Time
0.00kWh ~ 200GWh
0~1
10Wh
0.01
±1.5±10 counts
±0.03
0.00 ~ 20.00
0.01
±5%
0.0 ~ 5.0%
0.0 ~ 20.0%
-360° ~ 0°
-360° ~ 0°
0.1%
0.1%
1°
1°
±0.5%
±1%
±2digits
±5digits
±6000Vpk
10 ~ 1000Vrms
50us
1V
1V
±15%
±2.5%
1 ~ 50
1 ~ 49
0.0 ~ 100.0%
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 11
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Sampling Rate
Inrush Current
Arms(AC+DC)
Inrush Duration
Logger
Recording
Memory
Max. recording time
System Monitor
Parameters
Record Time
Record Event Number
Limits
General Characteristics
Power
Interface
Display
Battery
Dimension & Weight
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
20kS/s
0~3000Arms
6s ~ 32min selectable
0.1
10ms
±1% ± 5digits
±20ms
Parameter, duration time and time interval can be set by user,
which can be export on PC
8G
1 year
Vrms,Arms,Harmonic Volts,THD
Volts,Plt,Vrms1/2,Arms1/2,Vneg,Hz,dips and swells,
unbalance
2h ~ 7days
>10000
According EN50160 or customer definable
AC220V(1±10%), 50Hz(1±5%), ≤10VA
USB_HOST, LAN
5.6' TFT LCD, 320*240
7.4V, 4.4Ah, > 7 hours working time
262×173×66mm, 1.6kg
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 12
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1.3 ZES Zimmer LMG500
1.3.1 Introduction
The ZES Zimmer LMG500 is a 1 to 8 Channel Precision Power Analyser.
The LMG500 is best-in-class for measurements of:

Devices, e.g. E-machines, frequency inverters, and transformers;

Installations and associated elements;

Power grids and consumer electrical networks to determine interactions; and

Components, e.g. ferrite cores, semiconductors, and capacitors.
Other applications include:

CE compliance tests on devices;

Analysing the feedback of harmonics and flicker (load variations); and

Standby power consumption.
1.3.2 Key Features
The most important features of the LMG500 are:

Wide dynamic measuring range from 3V to 1000V/3200Vpeak, 20mA to 32A/120A
peak in direct measurement only by a single pair of sockets for each voltage and
current input;

Modular with 1 to 8 power measuring channels;

Measuring accuracy at 45 to 65Hz 0.015% of reading plus 0.01% of range;

3MSample/s per channel, absolutely gapless sampling with the evaluation of all
sampling values;
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 13
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831

Capturing transients and fast signal changes by event triggering in parallel to the
ongoing measurement;

Group delay between voltage and current measuring input <3ns as standard to
ascertain very precise measurements at low cosj and / or high frequencies;

Harmonics and interharmonics up to 50kHz internally, and up to 1MHz with an
external PC;

Flicker, interactions between network and load;

Ergonomic user interface for easy, intuitive use of the power analyser;

Real-time evaluation of the measurements in numeric tables and diagrams; and

Data communication interfaces with high transfer rates (RS232, USB, IEEE488.2,
Ethernet).
1.3.3 Device Interface
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 14
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1.3.4 Connections
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 15
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
2 Logging Instruments
2.1 Load Logger
2.1.1 Introduction
The Mirrin Multi Channel Load Logger (MLL) measures AC RMS current (load) up to four
channels and is ideal for monitoring loads on circuits and switchboards to record load
profiles that can be used to identify slow changing events such as long duration
interruptions, outages and derive estimates of usage patterns. The MLL is also useful as a
diagnostic tool to assess load sharing on single phase circuits and load balancing on three
phase systems.
The MLL incorporates a Liquid Crystal Display (LCD) which shows the maximum current
measurement in each channel together with the date-time stamp of its occurrence and
therefore ideally suited as a Maximum Demand Indicator (MDI).
The MLL is housed in a small light-weight polycarbonate weatherproof box.
Some common monitoring applications include: ac motors and pumps for pool, irrigation,
lighting, data centres, air conditioning equipment, transformer monitoring and switchboards.
2.1.2 Feature summary







Logs four (4) current channels (standard) and two (2) temperature channels
(optional);
Programmable logging interval, minimum one second;
programmable alarms;
Over two years memory capacity at 10 minute logging interval (8GB SD card
included);
Displays the maximum demand and maximum temperature with a date-time stamp
for each channel;
Bluetooth enabled for Android devices that provides for online measurements,
graphical displays and options to download data and email;
Battery operated with power saving mode to extend battery life to near 12 months;
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 16
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au


Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Facility for external DC power source including solar charging; and
Suitable for indoor and outdoor applications.
2.1.3 Kit
Includes:
 MLL;
 Four (4) flexible current sensors (600mm in length);
 Communications cable;
 Application software for PC;
 Application software for Android based device; and
 Carry bag.
2.1.4 Accessories
Communications cable
Carry bag
Flexible current sensor
rated at 3000A (CATIV 600V)
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Clamp-on current sensor
rated at 500A (CA TIV 600V)
Page 17
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Temperature sensor 5m
(magnetic mount)
Temperature sensor 5m
2.1.5 Options
Includes:
 Various flexible current sensors of smaller diameter;
 15mm clamp-on current transformers;
 External power supplies:
o Solar panel rated at 12V;
o Parasitic clamp-on current transformer power supply;
o USB supply via communications cable;
 Other inputs:
o Two temperatures. Requires temperature connections on the MLL;
 Mounting:
o Flanged case;
o Magnetic feet; and
o Holster.
2.1.6 Specifications
PARAMETER
Input Channels
Current Inputs (AC RMS)
Temperature Inputs (optional)
4 channels - Phases A, B, C and Neutral
2 x PT100 RTD
Communications
Serial Data (standard)
Wireless (optional)
TTL serial; Baud Rate: 230400
Bluetooth
Sampling
A to D Conversion
Sampling Rate
Instantaneous measurement
Maximum measurement
Logging
Logged Data Memory
Logging Interval
MIRRIN MULTI-CHANNEL LOAD LOGGER
12 bits
1600Hz (1600 samples per second)
RMS aggregation of four cycles 250ms apart and updated
every second
Based on the instantaneous measurements using a 60second exponential time constant.
256KB; expandable to 8GB (SD card)
Programmable from 1 second
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 18
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Measurements
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Accuracy
System Accuracy
Current (RMS), Max. Current (RMS), Current Unbalance (not
yet implemented), Temperature (not yet implemented)
±0.5% (excludes current sensor)
±1% (clamp-on current sensor)
Outputs
Visual Tools
Data File
Visual Indicator
Graphical Interface
Mirrin format binary with CSV export
2 x Status LED
General
Display (optional)
Current Sensors
Battery Supply
External Supply
Battery Life
LCD: Time-stamped current and max. current
Flexible current sensors or clamp-on current probes Automatic detection
Two non-rechargeable ‘AA” cells. Energizer® Ultimate
Lithium AA batteries recommended.
5V dc adaptor.
Four months typical. Extended to twelve months in Power
Saving Mode
Environment
Use
Altitude
Operating Temperature
Relative Humidity
Degree of Protection
Safety Category
Indoor and outdoor
Up to 2000m.
-20°C to 70°C
80% for temperatures up to 70°C
IP65
IEC 61010-1,CAT IV 600V defined by CT
Electromagnetic Compatibility
Emissions
Immunity
AS/NZS CISPR 22: 2002 Class A
EN61000-4-3:1995, including Amdt 1:1998
Physical
Dimensions (H x W x L)
Weight
Case Material and Colour
55 x 90 x 145 mm
400g (battery included)
Polycarbonate, moulded in light grey
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 19
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
3 Remote (Online) Monitoring Systems
3.1 Load Remote
Load Remote is a Remote Terminal Unit (RTU) that measures AC current in up to five (5)
circuits and facilitates on-line monitoring. All data is transmitted back to a secure database
utilising modern communication networks with programmable intervals. The user is provided
with a web login and password and able to quickly retrieve, view and download data on-line.
HARDWARE
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
INSTALLATION
Page 20
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Load Remote is also useful as a diagnostic tool to assess load sharing and load balancing
on single and three phase systems. Load Remote is intended for applications requiring long
term monitoring and where periodic site visits may not be feasible or access is difficult.
Some common monitoring applications include: ac motors and pumps for pool, irrigation,
lighting, data centres, air conditioning equipment and switchboards.
Digital inputs/outputs and alarm thresholds available for control and condition monitoring
applications. This product can be customised to your specific requirements.
PARAMETER
General electrical
Rated load current
Working voltage
Power source
Channels
AC current (1)
Temperature (2)
Communications
Remote communications
SPECIFICATION
Up to 3000A.
600V as defined by current sensor.
External 12V DC.
AC current, up to five (5) channels or circuits.
Optional: Temperature inputs. Combinations of (1) and (2)
totalling five channels.
Device communications
Tri-Band UMTS (850MHz/900MHz/2100MHz); Dual-Band
GSM/GPRS (900MHz/1800MHz).
RS-232 for programming
Data Pitching
Programmable transmit interval
1 minute minimum
Physical
Dimensions (H x W x D)
Material
Rating
Operating temperature
171 x 121 x 55 mm
Polycarbonate, moulded in light grey
IP65, NEMA4
-20°C to 70°C
Load Remote can be packaged into a suitable enclosure to meet your requirements and with
various current probes.
3.2 Monitoring Back-Up Generators
OmniMetrix is a leader and pioneer in wireless remote monitoring, control and diagnostics
for emergency power generator systems. With over 15 years of experience and thousands of
monitored generators, OmniMetrix is the proven solution for making emergency power
systems more reliable. The OmniMetrix system is currently installed globally on a wide range
of critical facilities, including cell towers, grocery stores, medical facilities, data centers and
public transportation systems, as well as federal, state and municipal government facilities.
As a system that facility maintenance teams have described as vital, we get better
information to the right people faster.
OmniMetrix’s robust M2M (machine to machine) 24/7 monitoring system increases the
reliability of your generators by eliminating 95% of all Fail-to-Start situations. Cost-effective
monitors connect to all major brands of generators and are Modbus compatible.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 21
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
3.2.1 G8500 SINGLE GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 22
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
3.2.2 G8600 MULTIPLE GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 23
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
3.2.3 G8700 MOBILE GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 24
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
3.2.4 G8800 RESIDENTIAL GENERATOR SYSTEM
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 25
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
4 Current Probes and Sensors
4.1 Flexible Current Sensors
PARAMETER
Electrical
Rated Input Current
Calibrated Output @ 1000A 50Hz
Load resistance
Bandwidth
Accuracy (@ 25°C, 50Hz)
Linearity (10% to 90% of range
Phase Error (45Hz - 65Hz)
Position Sensitivity
Temperature Coefficient
External Field (with cable
>100mm from the head)
Working Voltage
General
Probe and Cable Material
Coupling Material
Probe Cable Diameter
Probe Cable Length
Probe Cable Conductor Diameter
Output Cable Length
Operating Temperature Range
Storage Temperature Range
Operating Humidity
Degree of Protection
Colour
1AFF3000-6 (3000A)
(use with PM35)
SAF3000_6B (3000A)
(use with PM45)
3000A
78mV
4.5KΩ
10Hz to 20kHz
± 0.5% of reading
± 0.2% of reading
± 1°
± 2% of reading
± 0.05% of reading / °C
± 0.25% of range
3000A
78mV
4.5KΩ
10Hz to 20kHz
± 0.5% of reading
± 0.2% of reading
± 1°
± 2% of reading
± 0.05% of reading / °C
± 0.25% of range
1000V AC or DC
1000V AC or DC
Alcryn 2070 NC double
insulated, UL94 V-0
Ultramid A3U Q720, UL94 V-0
9.9mm (nominal)
610mm
194mm
2m, terminated with Brad
Harrison 8A4000-315
-20°C to +65°C
-40°C to +75°C
15% to 85% (non-condensing)
IP65
Probe: Green RAL6018
Alcryn 2070 NC double
insulated, UL94 V-0
Ultramid A3U Q720, UL94 V-0
9.9mm (nominal)
610mm
194mm
2m UL.M12 4P F ST 2M PUR0.34
-20°C to +65°C
-40°C to +75°C
15% to 85% (non-condensing)
IP65
Probe: Green RAL6018
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 26
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
PARAMETER
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1ACF3000-6 (3000A)
(use with PM35)
1AF3000-6 (3000A)
(use with PM45)
Electrical
Maximum Measureable Current
Internal Resistance
Accuracy
Linearity
Output Signal (Sinusoidal)
Frequency Range
Position Sensitivity
Influence of External Field
Temperature Coefficient
Working Voltage (max.)
Safety Category (IEC 61010-1)
High Voltage Withstand
100kA at (50/60)Hz
30Ω per 400mm
± 1% (Calibrated)
± 0.2% (Calibrated)
100mV/KA @ 50Hz
20Hz to 5kHz
± 2% maximum
± 2% maximum
± 0.07% per °C
1000V at (50/60)Hz
1000V CAT III / 600V CATIV
7400VAC (50/60)Hz for 1 minute
100kA at (50/60)Hz
30Ω per 400mm
± 1% (Calibrated)
± 0.2% (Calibrated)
100mV/KA @ 50Hz
20Hz to 5kHz
± 2% maximum
± 2% maximum
± 0.07% per °C
1000V at (50/60)Hz
1000V CAT III / 600V CATIV
7400VAC (50/60)Hz for 1 minute
Dimensions
Cable length
Coil Inside Diameter A
Coil Outside Diameter B
Coil Length C
Cap Coupling cross section D
Cap Coupling cross section E
Coil cross-section F
2m
170mm
201mm
600mm
18mm (min.)
23mm (max.)
15.5mm
2m
170mm
201mm
600mm
18mm (min.)
23mm (max.)
15.5mm
Shield
Thermoplastic RUBBER, flame
retardant UL 94 V-O rated
Polypropylene UL 94 V-O rated
Blue
Black
1000V UL Style 20940;
Diameter: 5.5mm - wires 2 x
24AWG
85% coil, 100% output cable
Thermoplastic RUBBER, flame
retardant UL 94 V-O rated
Polypropylene UL 94 V-O rated
Blue
Black
1000V UL Style 20940;
Diameter: 5.5mm - wires 2 x
24AWG
85% coil, 100% output cable
Environmental
Working Temperature
Relative Humidity
Pollution Degree
Maximum Altitude
-20°C to +70°C
85% (non-condensing)
2
2000m
-20°C to +70°C
85% (non-condensing)
2
2000m
Materials
Transducer and cable
Couplings
Colour (transducer)
Colour (Cable and couplings)
Cable
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 27
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
4.2 Clamp on Current Sensors
PARAMETER
General electrical
Rated Input Current
Maximum Input Current
Output Signal
Burden
Accuracy
Frequency Range
Dielectric Strength
Working Voltage
Physical
Dimensions (H x W x L)
Jaw Aperture
Weight
Colour
Safety Class
Operating temperature
Relative Humidity
1AC10 (10A)
(use with PM45)
1ACR100S (100A)
(use with PM35)
1AC100S (100A)
(use with PM45)
10A.
15A.
440mV @ 10A.
Included
±1.0%
45Hz - 5000Hz
3000V @ 60Hz for 1
minute
Bare conductor: 30V;
Insulated conductor:
600V
100A.
150A.
440mV @ 100A.
2.2 Ω (external)
±1.0%
45Hz - 5000Hz
3000V @ 60Hz for 1
minute
Bare conductor: 30V;
Insulated conductor:
600V
100A.
150A.
440mV @ 100A.
Included
±1.0%
45Hz - 5000Hz
3000V @ 60Hz for 1
minute
Bare conductor: 30V;
Insulated conductor:
600V
(90.5 x 41.2 x 23.8) mm
(14.3 x 15.9) mm
113 grams (excluding
lead and connector)
Grey / light grey
Class III per IEC 610101
-20°C to 50°C
85% (non-condensing)
(90.5 x 41.2 x 23.8) mm
(14.3 x 15.9) mm
113 grams (excluding
lead and connector)
Grey / light grey
Class III per IEC 610101
-20°C to 50°C
85% (non-condensing)
(90.5 x 41.2 x 23.8) mm
(14.3 x 15.9) mm
113 grams (excluding
lead and connector)
Grey / light grey
Class III per IEC 610101
-20°C to 50°C
85% (non-condensing)
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 28
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
PARAMETER
General electrical
Rated Input Current
Maximum Input Current
Output Signal
Burden
Accuracy (Ratio Error)
Maximum Error (Ratio
Error)
Phase Error
Maximum Burden
Accuracy Class
Double Insulation
Frequency Range
Dielectric Strength
Working Voltage
Physical
Dimensions (H x W x L)
Jaw Aperture
Weight
Encapsulation / Colour
Safety Class
Operating temperature
1ACR100 (100A)
(use with PM35)
100A
120A
440mV @ 100A.
Included
Better than ±1.0%
1% accuracy from
20% to 125% of rated
current
<0.36 degrees at rated
current
15VA
0.5M AS1675
300V AC RMS
40Hz - 5000Hz
Telephone:
Fax:
ABN:
1ACR500 (500A)
(use with PM35)
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
1ASC500 (500A)
(use with PM45)
500A
650A
440mV @ 500A.
Included
500A
650A
440mV @ 500A.
Included
1.5% @ 5% and 0.5%
@110% of rated
current
1.5% @ 5% and 0.5%
@110% of rated
current
3000V @ 60Hz for 1
minute
650V
15VA
0.5M AS1675
300V AC RMS
5Hz - 5000Hz; 0.5%
R.E. (40-85) Hz
3000V @ 60Hz for 1
minute
650V
15VA
0.5M AS1675
300V AC RMS
5Hz - 5000Hz; 0.5%
R.E. (40-85) Hz
3000V @ 60Hz for 1
minute
650V
(99 x 210 x 60) mm
52 mm
750 grams (excluding
lead and connector)
Fully insulated / Black
CAT III per IEC 610101
-10°C to 50°C
(99 x 210 x 60) mm
52mm
750 grams (excluding
lead and connector)
Fully insulated / Black
CAT III per IEC 610101
-10°C to 50°C
(99 x 210 x 60) mm
52mm
750 grams (excluding
lead and connector)
Fully insulated / Black
CAT IV per IEC
61010-1
-10°C to 50°C
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 29
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
4.3 Miniature Split-Core Current Transformers
4.3.1 Key Features and General Specifications














Lightweight, safe (includes internal burden),
quick and easy installation - no power line
disruption required.
Rated primary current: up to 400Aac
Rated secondary: 0.333Vac at rated primary
Current
Class (accuracy): 0.5, 1.0, 3.0 [IEC 60044-1]
Rated security coefficient: FS<5
Case material: Nylon resin UL flame retardant
Rating 94-VO
Highest voltage for equipment Um (rms): 720Vac
Rated power-frequency withstand voltage (rms):
3000Vac
Frequency range: (50/60) Hz
Operating temperature: 15 to 60
RoHS compliant
CE approved
ETL approved, CAT II 600V
Leads: 0.8 Foot (240mm), UL 1015, twisted pair,
0.34m2 (22AWG)
4.3.2 Range
Description
Input: 1-25A;Output: 0.333V@ 25A; Class: 1.0; Cable diameter: 10.2mm
Input: 5-100A;Output: 0.333V@ 100A; Class: 0.5; Cable diameter: 16.2mm
Input: 5-200A;Output: 0.333V@ 200A; Class: 0.5; Cable diameter: 24.2mm
Input: 5-400A;Output: 0.333V@ 400A; Class: 0.5; Cable diameter: 35.2mm
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Part Number
CTSA010
CTSA016
CTSA024
CTSA035
Page 30
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
4.4 Substation Current Transformer Converters
4.4.1 Introduction
CK1: 1 Amp Substation CT Converter
CK5: 5 Amp Substation CT Converter
The CK1 or CK5 Powermonic Current Transformer (CT) Converter is a three phase device that
transforms the standard 1A or 5A secondary current from a CT to a 200 mA output current suitable for
direct connection to a Powermonic CT input.
Internal protection is provided to enable the output leads to be disconnected from the Powermonic
without affecting the CT secondary circuits.
The units are designed for high accuracy and therefore lend themselves for Metering and Power
Quality applications.
4.4.2 Specifications
PARAMETER
Electrical
Rated Input Current
Rated Output Current
Accuracy Class
Working Voltage
General
Input Connections
Output Connections
Enclosure
Weight
Dimensions (W x L x D)
Including glands and sockets
CK1 (1A to 200mA)
CK5 (5A to 200mA)
1A
200mA
0.5M (AS1675)
1000V AC or DC
5A
200mA
0.5M (AS1675)
1000V AC or DC
Red, White and Blue banana
sockets
Colour coded 1.8m leads with
4 pin connectors to suite
PM20, PM30, PM30+, PM40
Light grey polycarbonate
4.4kg
(140 x 230 x 100) mm
(140 x 280 x 100) mm
Red, White and Blue banana
sockets
Colour coded 1.8m leads with 4
pin connectors to suite PM20,
PM30, PM30+, PM40
Light grey polycarbonate
4.4kg
(140 x 230 x 100) mm
(140 x 280 x 100) mm
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 31
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5 Instrument Current Transformers
Australian Standard 60044.1-2007 Instrument transformers Part 1: Current transformers
(IEC 60044-1 Ed.1.2 (2003) MOD).
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 32
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.1 Metering
5.1.1 Measuring - PVC
The SES range of PVC tape insulated metering CTs are designed and manufactured to
cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are
certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A.
Ratio
60/5 A
100/5 A
150/5 A
200/5 A
250/5 A
300/5 A
400/5 A
500/5 A
600/5 A
800/5 A
1000/5 A
1200/5 A
1600/5 A
2000/5 A
2500/5 A
3000/5 A
3500/5 A
4000/5 A
5000/5 A
ID
28
34
34
45
45
45
60
65
65
85
85
90
90
123
123
123
143
143
143
Class 3 5VA
OD
70
74
74
80
80
80
96
100
100
122
122
135
135
162
162
162
185
185
185
HT
28
23
23
28
28
28
23
23
23
23
23
23
23
23
23
23
28
28
28
ID
28
34
34
34
45
45
60
68
68
85
85
90
90
123
123
123
143
143
143
Class 1 15VA
OD
70
80
80
80
80
80
96
100
100
122
122
135
135
162
162
162
185
185
185
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
HT
102
72
48
33
38
38
23
23
23
28
28
28
28
23
23
23
28
28
28
Class 0.5 15VA
ID
OD
HT
34
34
34
45
45
60
65
85
85
90
90
122
122
122
140
140
140
140
80
100
80
80
80
96
100
100
122
122
135
135
165
165
165
190
190
190
185
72
92
70
60
40
30
30
40
30
33
33
33
35
35
30
30
35
Page 33
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.1.2 Measuring - MBQ Series
MBQ series current transformers are ideally designed for bus bar mounting and find
applications in measurement, test and control of electrical equipment. The MBQ current
transformer is housed into a case of PPO flame retardant material.
Type
MBQ 60/30
MBQ 60/40
MBQ 95/50
MBQ 95/70
MBQ 130/100
Type
Ratio
100/5 A
125/5 A
150/5 A
200/5 A
250/5 A
300/5 A
400/5 A
500/5 A
600/5 A
750/5 A
800/5 A
1000/5 A
1200/5 A
1250/5 A
1500/5 A
1600/5 A
2000/5 A
2500/5 A
3000/5 A
A
75
75
105
105
167
MBQ 60/30
Burden (VA)
Class
Class
1
0.5
2.5
1.5
2.5
1.5
2.5
2.5
5
5
5
5
5
5
5
5
10
5
10
5
B
60
60
95
95
129
C
30
30
40
40
60
D
30 x 10
40 x 10
60 x 30
60 x 10
100 x 55
MBQ 60/40
Burden (VA)
Class
Class
1
0.5
2.5
2.5
5
5
5
5
10
10
10
1.5
1.5
2.5
2.5
2.5
2.5
5
5
5
MBQ 95/50
Burden (VA)
Class
Class
1
0.5
2.5
5
10
10
10
10
15
15
15
15
15
15
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
1.5
2.5
5
5
5
5
10
10
10
15
15
15
MBQ 95/70
Burden (VA)
Class
Class
1
0.5
2.5
2.5
5
10
15
15
15
15
15
15
15
15
15
1.5
1.5
2.5
5
10
10
10
10
15
15
15
15
15
MBQ 130/100
Burden (VA)
Class
Class
1
0.5
5
10
10
15
15
15
15
15
15
15
15
Page 34
2.5
5
5
10
10
10
15
15
15
15
15
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.1.3 Measuring - MSQ Series
MSQ series current transformers are ideally designed for bus bar mounting and find
applications in measurement, test and control of electrical equipment. The MSQ current
transformer is housed into a case of PPO flame retardant material.
FEATURES:
 Flame retardant
 High mechanical strength
 High dielectric strength
 Transparent sealable terminal cover
 Base or Bus bar mounting
Type
MSQ 30
MSQ 40
MSQ 60
MSQ 85
MSQ 100
MSQ 125
A
98
98
127
164
156
220
B
75
75
101
128
144
190
C
43
43
44
42
44
42
D
30 x 10
40 x 10
60 x 20
80 x 30
100 x 10
125 x 58
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 35
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Type
Ratio
100/5 A
125/5 A
150/5 A
200/5 A
250/5 A
300/5 A
400/5 A
500/5 A
600/5 A
750/5 A
800/5 A
1000/5 A
1200/5 A
1250/5 A
1500/5 A
1600/5 A
2000/5 A
2500/5 A
3000/5 A
4000/5 A
5000/5 A
6000/5 A
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
MSQ 30
MSQ 40
MSQ 60
MSQ 85
MSQ 100
MSQ 125
Burden (VA)
Burden (VA)
Burden (VA)
Burden (VA)
Burden (VA)
Burden (VA)
Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5
5
2.5
1.5
1.5
5
2.5
1.5
1.5
5
5
2.5
1.5
10
5
5
2.5
10
10
5
2.5
2.5
1.5
15
10
5
2.5
5
2.5
15
15
10
5
10
5
7.5
5
15
15
10
5
10
5
7.5
5
15
15
15
10
10
5
10
5
7.5
5
15
10
10
5
10
5
7.5
5
15
10
15
10
10
5
10
5
15
10
15
10
15
10
10
5
15
15
15
10
15
10
15
10
15
15
15
10
15
10
15
10
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 36
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.1.4 Measuring - Tape Insulated Ring Type - KTM Series
Part Number
Ratio
KTM1R30PD
KTM1R40PD
KTM1R50PD
KTM1R50QD
KTM1R75PD
KTM1R75QD
KTM1R100QB
KTM1R100RB
KTM1R125QB
KTM1R125RB
KTM1R150QB
KTM1R150TB
KTM1R150QA
KTM1R200QB
KTM1R200QA
KTM1R200TB
30/5 A
40/5 A
50/5 A
50/5 A
75/5 A
75/5 A
100/5 A
100/5 A
125/5 A
125/5 A
150/5 A
150/5 A
150/5 A
200/5 A
200/5 A
200/5 A
Part Number
Ratio
KTM2R100QB
KTM2R125QB
KTM2R150QB
KTM2R150QA
KTM2R200QB
KTM2R200QA
KTM2R200TB
KTM2R250QB
KTM2R250QA
KTM2R250TB
KTM2R300QB
KTM2R300QA
100/5 A
125/5 A
150/5 A
150/5 A
200/5 A
200/5 A
200/5 A
250/5 A
250/5 A
250/5 A
300/5 A
300/5 A
Burden
(VA)
2.5
2.5
2.5
5
2.5
5
5
7.5
5
7.5
5
7.5
15
5
5
15
Burden
(VA)
5
5
5
5
5
5
15
5
5
15
5
5
Class
ID
OD HT
5
5
5
5
5
5
5
1
1
1
1
1
0.5
1
0.5
1
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
75
75
75
75
75
80
80
75
80
75
80
80
75
75
75
75
70
55
45
75
35
60
70
90
60
65
40
80
75
30
45
55
Class
ID
OD
HT
1
1
1
0.5
1
0.5
1
1
0.5
1
1
0.5
45
45
45
45
45
45
45
45
45
45
45
45
95
90
90
95
90
90
90
90
95
90
90
90
100
55
45
90
30
60
60
30
40
50
25
30
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 37
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
KTM2R300TB
KTM2R400QB
KTM2R400QA
KTM2R400TB
KTM2R400TA
300/5 A
400/5 A
400/5 A
400/5 A
400/5 A
Part Number
15
5
5
15
15
Ratio
KTM3R300QB
300/5 A
KTM3R300QA
300/5 A
KTM3R300TB
300/5 A
KTM3R400QB
400/5 A
KTM3R400QA
400/5 A
KTM3R400TB
400/5 A
KTM3R400TA
400/5 A
KTM3R500QB
500/5 A
KTM3R500QA
500/5 A
KTM3R500TB/TA
500/5 A
KTM3R600QB/QA 600/5 A
KTM3R600TB/TA 600/5 A
Part Number
KTM4R600QB/QA
KTM4R600TB/TA
KTM4R800QB
KTM4R800QA
KTM4R800TB/TA
KTM4R1000QB/QA
KTM4R1000TB/TA
KTM4R1200/QA/
Part Number
KTM5R800QB/QA
KTM5R800TB/TA
KTM5R1000QB/QA
KTM5R1000TB/TA
KTM5R1200QA
KTM5R1200TB/TA
KTM5R1600QB/QA/TB
Part Number
KTM6R1000QB/QA
1
1
0.5
1
0.5
Burden
(VA)
5
5
15
5
5
15
15
5
5
15
5
15
Ratio
600/5 A
600/5 A
800/5 A
800/5 A
800/5 A
1000/5 A
1000/5 A
1200/5 A
Ratio
800/5 A
800/5 A
1000/5 A
1000/5 A
1200/5 A
1200/5 A
1600/5 A
Ratio
1000/5 A
45
45
45
45
45
Telephone:
Fax:
ABN:
90
90
90
90
90
45
25
25
35
45
Class
ID
OD
HT
1
0.5
1
1
0.5
1
0.5
1
0.5
1/0.5
1/0.5
1/0.5
55
55
55
55
55
55
55
55
55
55
55
55
95
95
100
100
105
100
120
100
105
100
105
105
35
45
50
25
35
45
40
25
30
40
30
40
Burden
(VA)
5
15
5
5
15
5
15
5/15
Burden
(VA)
5
15
5
15
5
15
5/15
Burden
(VA)
5
Class
ID
OD
HT
1/0.5
1/0.5
1
0.5
1/0.5
1/0.5
1/0.5
1/0.5
70
70
70
70
70
70
70
70
120
120
120
110
120
120
120
120
30
40
30
30
35
30
35
30
Class
ID
OD
HT
1/0.5
1/0.5
1/0.5
1/0.5
0.5
1/0.5
1/0.5
85
85
85
85
85
85
85
125
140
125
140
140
140
140
30
35
30
30
30
30
30
ID
OD
HT
115 155
30
Class
1/0.5
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 38
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
KTM6R1000TB/TA
KTM6R1200QB/QA
KTM6R1200TB/TA
KTM6R1600QB/
KTM6R2000TB/TA
KTM6R2500TB/TA
KTM6R3000TB/TA
KTM6R3500TB/TA
Part Number
KTM7R3000TB/TA
KTM7R3500TB/TA
KTM7R4000TB/TA
KTM7R4500TB/TA
KTM7R5000TB/TA
KTM8R4000TB/TA
KTM8R4500TB/TA
KTM8R5000TB/TA
1000/5 A
1200/5 A
1200/5 A
1600/5 A
2000/5 A
2500/5 A
3000/5 A
3500/5 A
Ratio
3000/5 A
3500/5 A
4000/5 A
4500/5 A
5000/5 A
4000/5 A
4500/5 A
5000/5 A
15
5
15
5/15
15
15
15
15
Burden
(VA)
15
15
15
15
15
15
15
15
1/0.5
1/0.5
1/0.5
1/0.5
1/0.5
1/0.5
1/0.5
1/0.5
Telephone:
Fax:
ABN:
115
115
115
115
115
115
115
115
170
155
170
170
170
185
185
185
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
35
30
30
30
30
35
35
35
Class
ID
OD
HT
1/0.5/0.2
1/0.5/0.2
1/0.5/0.2
1/0.5/0.2
1/0.5/0.2
1/0.5/0.2
1/0.5/0.2
1/0.5/0.2
135
135
135
135
135
170
170
170
205
205
205
210
210
240
240
240
35
35
35
40
40
35
35
35
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 39
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.1.5 Measuring - Resin Cast Ring Type - KRM Series
Part Number
Ratio
KRM1R30PD
KRM1R40PD
KRM1R50PD
KRM1R50QD
KRM1R75PD
KRM1R75QD
KRM1R100QB
KRM1R100RB
KRM1R125QB
KRM1R125RB
KRM1R150QB
KRM1R150QA
KRM1R200QB
KRM1R200QA
KRM1R200TB
30/5 A
40/5 A
50/5 A
50/5 A
75/5 A
75/5 A
100/5 A
100/5 A
125/5 A
125/5 A
150/5 A
150/5 A
200/5 A
200/5 A
200/5 A
Part Number
Ratio
KRM2R100QB
KRM2R125QB
KRM2R150QB
KRM2R150QA
KRM2R200QB
KRM2R200QA
KRM2R200TB
KRM2R250QB
KRM2R250QA
KRM2R250TB
KRM2R300QB
KRM2R300QA
KRM2R300TB
100/5 A
125/5 A
150/5 A
150/5 A
200/5 A
200/5 A
200/5 A
250/5 A
250/5 A
250/5 A
300/5 A
300/5 A
300/5 A
Burden
Class ID
(VA)
2.5
5
30
2.5
5
30
2.5
5
30
5
5
30
2.5
5
30
5
5
30
5
1
30
7.5
1
30
5
1
30
7.5
1
30
5
1
30
5
0.5 30
5
1
30
5
0.5 30
15
1
30
OD
HT
80
95
75
80
95
75
80
90
75
80
75
80
75
75
80
80
40
65
80
40
65
80
135
65
80
65
80
40
65
70
Burden
Class ID OD HT
(VA)
5
1
45 100 100
5
1
45 98 60
5
1
45 100 45
5
0.5 45 100 100
5
1
45 95 40
5
0.5 45 98 60
15
1
45 98 60
5
1
45 95 40
5
0.5 45 95 40
15
1
45 100 45
5
1
45 95 40
5
0.5 45 95 40
15
1
45 100 45
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 40
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
KRM2R400QB
KRM2R400QA
KRM2R400TB
KRM2R400TA
400/5 A
400/5 A
400/5 A
400/5 A
Part Number
KRM3R300QB
KRM3R300QA
KRM3R400QB/QA
KRM3R400TB
KRM3R300QB
KRM3R300QA
KRM3R400QB/QA
KRM3R400TB
KRM3R400TA
KRM3R500QB/QA
KRM3R600QB/QA
Part Number
KRM4R600QB/QA
KRM4R600TB
KRM4R600TA
KRM4R800QB/QA
KRM4R1000QB/QA
KRM4R1000TB/TA
KRM4R1200QB/QA
Part Number
KRM5R800QB/QA
KRM5R1000QB/QA
KRM5R1200QB/QA
KRM5R1600QB/QA/
KRM6R1000QB/QA
5
5
15
15
Ratio
300/5 A
300/5 A
400/5 A
400/5 A
300/5 A
300/5 A
400/5 A
400/5 A
400/5 A
500/5 A
600/5 A
1
0.5
1
0.5
Burden
(VA)
5
5
5
15
5
5
5
15
15
5/15
5/15
Ratio
600/5 A
600/5 A
600/5 A
800/5 A
1000/5 A
1000/5 A
1200/5 A
Ratio
800/5 A
1000/5 A
1200/5 A
1600/5 A
1000/5 A
Telephone:
Fax:
ABN:
45
45
45
45
40
40
40
40
95
95
95
95
Class
ID
OD
HT
1
0.5
1/0.5
1
1
0.5
1/0.5
1
0.5
1/0.5
1/0.5
55
55
55
55
55
55
55
55
55
55
55
95
100
95
98
95
100
95
98
115
95
100
40
45
40
60
40
45
40
60
35
40
45
Burden
(VA)
5
15
15
5/15
5
15
5/15
Burden
(VA)
5/15
5/15
5/15
5/15
5/15
Class
ID
OD
HT
1/0.5
1
0.5
1/0.5
1/0.5
1/0.5
1/0.5
70
70
70
70
70
70
70
115
115
140
115
115
140
115
35
35
25
35
35
25
35
Class
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
ID
1/0.5 85
1/0.5 85
1/0.5 85
1/0.5 85
1/0.5 115
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
OD
HT
140
140
140
145
175
25
25
25
35
30
Page 41
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.1.6 Measuring - Resin Cast Ring Type - KSM Series
Part Number
Ratio
KSM1R30PD
30/5 A
KSM1R40PD
40/5 A
KSM1R50QD
50/5 A
KSM1R100QB 100/5 A
KSM1R150QD 150/5 A
KSM1R150TB 150/5 A
KSM1R200QB 200/5 A
KSM1R200TB 200/5 A
Part Number
Ratio
KSM2R150QD
KSM2R150QB
KSM2R200QB
KSM2R200TB
KSM2R250QB
KSM2R250TB
KSM2R300QB
KSM2R300TB
KSM2R300SA
KSM2R400QB
KSM2R400TB
KSM2R400SA
150/5 A
150/5 A
200/5 A
200/5 A
250/5 A
250/5 A
300/5 A
300/5 A
300/5 A
400/5 A
400/5 A
400/5 A
Burden
Class ID OD HT
(VA)
2.5
5
30 85 85
2.5
5
30 90 40
5
5
30 85 85
5
1
30 85 85
5
5
30 90 40
15
1
30 85 85
5
1
30 90 40
15
1
30 80 60
Burden
Class ID OD HT
(VA)
5
5
45 90 40
5
1
45 100 40
5
1
45 90 40
15
1
45 100 65
5
1
45 90 40
15
1
45 100 65
5
1
45 90 40
15
1
45 100 40
10
0.5 45 100 40
5
1
45 90 45
15
1
45 100 40
10
0.5 45 90 45
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 42
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Part Number
Ratio
KSM3R300TB
KSM3R300SA
KSM3R400TB
KSM3R400SA
KSM3R500TB
KSM3R500SA
KSM3R600TB
KSM3R600SA
300/5 A
300/5 A
400/5 A
400/5 A
500/5 A
500/5 A
600/5 A
600/5 A
Part Number
Ratio
KSM4R800TA
800/5 A
KSM4R1000TA 1000/5 A
KSM4R1200TA 1200/5 A
Part Number
KSM5R800TA
KSM5R1000TA
KSM5R1200TA
KSM5R1200TE
KSM5R1600TE
Part Number
KSM6R1000TA
KSM6R1000TE
KSM6R1200TA
KSM6R1200QE
KSM6R1200TE
KSM6R1600TA
KSM6R1600TE
KSM6R2000TA
KSM6R2000SE
KSM6R2000TE
KSM6R2500TE
KSM6R3000TE
KSM6R3500TE
Ratio
800/5 A
1000/5 A
1200/5 A
1200/5 A
1600/5 A
Ratio
1000/5 A
1000/5 A
1200/5 A
1200/5 A
1200/5 A
1600/5 A
1600/5 A
2000/5 A
2000/5 A
2000/5 A
2500/5 A
3000/5 A
3500/5 A
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Burden
Class ID OD HT
(VA)
15
1
55 100 65
10
0.5 55 100 65
15
1
55 120 40
10
0.5 55 100 40
15
1
55 100 45
10
0.5 55 100 40
15
1
55 100 40
10
0.5 55 100 40
Burden
Class ID OD HT
(VA)
15
0.5 70 120 40
15
0.5 70 120 40
15
0.5 70 120 40
Burden
Class ID OD HT
(VA)
15
0.5 85 145 40
15
0.5 85 145 40
15
0.5 85 145 40
15
0.2 85 145 40
15
0.2 85 145 40
Burden
Class ID OD HT
(VA)
15
0.5 115 175 40
15
0.2 115 175 40
15
0.5 115 175 40
5
0.2 115 175 40
15
0.2 115 175 40
15
0.5 115 175 40
15
0.2 115 175 40
15
0.5 115 175 40
10
0.2 115 175 40
15
0.2 115 175 40
15
0.2 115 175 40
15
0.2 115 175 40
15
0.2 115 175 40
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 43
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.2 Protection
5.2.1 Protection - PVC
The SES range of PVC tape insulated Protection CTs are designed and manufactured to
cater for wide range of applications. They are tested to IEC 60044-1 2003-02 and are
certified to ASTA and CE mark Certified to UL. The standard rated secondary current is 5A.
Ratio
60/5 A
100/5 A
150/5 A
200/5 A
250/5 A
300/5 A
400/5 A
500/5 A
600/5 A
800/5 A
1000/5 A
1200/5 A
1600/5 A
2000/5 A
2500/5 A
3000/5 A
3500/5 A
4000/5 A
5000/5 A
Class 10P5 15VA
ID
OD
HT
34
100
148
34
100
98
34
100
68
34
100
68
45
96
78
45
96
68
60
100
68
60
100
58
65
100
58
85
120
48
Class 10P10 15VA
ID
OD
HT
25
150
155
34
100
168
34
100
108
34
100
88
45
96
108
45
96
108
60
100
108
60
100
93
68
110
78
85
120
73
82
123
65
90
135
65
90
135
55
125
178
43
125
178
35
120
178
35
140
200
35
140
200
35
140
200
35
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Class 5P10 15VA
ID
OD
HT
25
150
165
34
100
180
34
100
130
34
100
110
45
96
110
45
96
120
45
96
100
60
100
110
68
110
88
85
120
88
82
123
80
90
135
80
90
135
70
125
178
43
125
178
35
120
178
35
140
200
35
140
200
35
140
200
35
Page 44
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.2.2 Protection - Tape Insulated Ring Type - KTP Series
Part Number
KTP1R100QL5
KTP1R100RL5
KTP1R100SL5
KTP1R150QM5
KTP1R150RL10
Part Number
KRP2R100QL5
KTP2R100SL5
KTP2R150RL10
KTP2R200QM10
KTP2R250QM10
Part Number
KTP3R300TM10
KTP3R400TM10
KTP3R500TM10
KTP3R600TM10
Part Number
KTP4R600TM10
KTP4R800TM10
KTP4R1000TM10
KTP4R1200TM10
Part Number
KTP5R800TM10
Ratio
100/5 A
100/5 A
100/5 A
150/5 A
150/5 A
Ratio
100/5 A
100/5 A
150/5 A
200/5 A
250/5 A
Ratio
300/5 A
400/5 A
500/5 A
600/5 A
Ratio
600/5 A
800/5 A
1000/5 A
1200/5 A
Ratio
800/5 A
Burden
Class
(VA)
5
10P5
7.5
10P5
10
10P5
5
5P5
7.5
10P10
ID
OD
HT
Part Number
Class
30
30
30
30
30
80
95
95
80
95
105
100
125
75
135
KTP1R100QM10
KTP1R100RM10
KTP1R100SM10
KTP1R150QM10
KTP1R150RM10
5P10 95 130
5P10 120 115
5P10 120 150
5P10 95 95
5P10 95 135
Burden
Class ID OD HT Part Number
(VA)
5
10P5 45 100 100 KTP2R100QM10
10
10P5 45 105 125 KTP2R100SM10
7.5
10P10 45 110 115 KTP2R150RM10
5
5P10 45 110 70 KTP2R200QM20
5
5P10 45 110 60 KTP2R250QM20
Burden
(VA)
15
15
15
15
Burden
(VA)
15
15
15
15
OD
HT
Class
OD
HT
5P10
5P10
5P10
5P20
5P20
110
140
110
110
110
115
135
115
120
115
Class
ID
OD
HT Part Number
Class
OD
5P10
5P10
5P10
5P10
55
55
55
55
140
140
130
135
80
70
65
65
5P5
5P20
5P20
5P20
130 60
130 140
140 110
145 100
KTP3R300TM5
KTP3R400TM20
KTP3R500TM20
KTP3R600TM20
HT
Class
ID
OD
HT Part Number
Class
OD
5P10
5P10
5P10
5P10
70
70
70
70
145
150
150
150
60
55
50
50
5P20
5P20
5P20
5P20
145 110
150 95
150 80
150 75
Class
OD
HT
5P20 180
80
KTP4R600TM20
KTP4R800TM20
KTP4R1000TM20
KTP4R1200TM20
Burden
Class ID OD HT Part Number
(VA)
15
5P10 85 170 55 KTP5R800TM20
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 45
HT
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
KTP5R1000TM10
KTP5R1200TM10
KTP5R1600TM10
Part Number
KTP6R2000TM10
KTP6R2500TM10
KTP6R3000TM10
KTP6R3500TM10
1000/5 A
1200/5 A
1600/5 A
Ratio
2000/5 A
2500/5 A
3000/5 A
3500/5 A
15
15
15
Burden
(VA)
15
15
15
15
Telephone:
Fax:
ABN:
5P10 85 170
5P10 85 170
5P10 85 170
50
50
45
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
KTP5R1000TM20
KTP5R1200TM20
KTP5R1600TM20
5P20 170
5P20 180
5P20 180
80
65
55
Class
ID
OD
HT Part Number
Class
OD
HT
5P10
5P10
5P10
5P10
115
115
115
115
190
190
190
195
50
45
45
50
5P20
5P20
5P20
5P20
195
195
200
215
65
60
60
50
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
KTP6R2000TM20
KTP6R2500TM20
KTP6R3000TM20
KTP6R3500TM20
Page 46
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.2.3 Protection - Resin Cast Ring Type - KRP Series
Part Number
KRP1R100QL5
KRP1R100SL5
KRP1R150QM5
KRP1R150RL10
Part Number
KRP2R100QL5
KRP2R100SL5
KRP2R200SM10
KRP2R250SM10
KRP2R300TM10
KRP2R400TM10
Part Number
KRP3R400TM10
KRP3R450TM10
KRP3R500TM10
KRP3R600TM10
Part Number
KRP4R600TM10
KRP4R800TM10
KRP4R1000TM10
KRP4R1200TM10
Part Number
Ratio
100/5 A
100/5 A
150/5 A
150/5 A
Ratio
100/5 A
100/5 A
200/5 A
250/5 A
300/5 A
400/5 A
Ratio
400/5 A
450/5 A
500/5 A
600/5 A
Ratio
600/5 A
800/5 A
1000/5 A
1200/5 A
Ratio
Burden
Class
(VA)
5
10P5
10
10P5
5
5P5
7.5
10P10
Burden
(VA)
5
10
10
10
15
15
Burden
(VA)
15
15
15
15
Burden
(VA)
15
15
15
15
ID
OD
HT
Part Number
30 100 75 KRP1R100QM10
30 90 135 KRP1R100SM10
30 80 70 KRP1R150QM10
30 90 135 KRP1R150RM10
Class
OD
HT
5P10 90 135
5P10 120 145
5P10 100 100
5P10 90 135
Class
ID
OD
HT
Part Number
Class
OD
HT
10P5
10P5
5P20
5P20
5P20
5P20
45
45
45
45
45
45
100
105
105
105
105
105
100
120
135
120
135
120
KRP2R100QM10
KRP2R100SM10
KRP2R200SM20
KRP2R250SM20
KRP2R300TM5
KRP2R400TM20
5P10
5P10
5P20
5P20
5P5
5P20
105
155
145
155
100
145
135
130
160
110
100
100
Class
ID
OD
HT Part Number
Class
OD
HT
5P20
5P20
5P20
5P20
55
55
55
55
140
120
140
140
70
90
70
70
5P20
5P20
5P20
5P20
155
155
145
145
130
110
100
100
KRP3R400TM20
KRP3R450TM20
KRP3R500TM20
KRP3R600TM20
Class
ID
OD
HT Part Number
Class
OD
5P20
5P20
5P20
5P20
70
70
70
70
140
140
140
140
70
70
70
70
5P20
5P20
5P20
5P20
155 110
145 100
155 90
155 90
Burden
Class
(VA)
ID
OD
HT Part Number
Class
OD
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
KRP4R600TM20
KRP4R800TM20
KRP4R1000TM20
KRP4R1200TM20
Page 47
HT
HT
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
KRP5R800TM10
KRP5R1000TM10
KRP5R1200TM10
KRP5R1600TM10
Part Number
KRP6R1000TM10
KRP6R1200TM10
KRP6R1600TM10
KRP6R2000TM10
KRP6R2500TM10
KRP6R3000TM10
KRP6R3500TM10
800/5 A
1000/5 A
1200/5 A
1600/5 A
Ratio
1000/5 A
1200/5 A
1600/5 A
2000/5 A
2500/5 A
3000/5 A
3500/5 A
15
15
15
15
Burden
(VA)
15
15
15
15
15
15
15
Telephone:
Fax:
ABN:
165
165
165
165
5P20
5P20
5P20
5P20
85
85
85
85
Class
ID
OD
HT Part Number
Class
OD
5P20
5P20
5P20
5P20
5P20
5P20
5P20
115
115
115
115
115
115
115
190
190
190
190
190
190
190
75
75
75
35
75
75
75
5P20
5P20
5P20
5P20
5P20
5P20
5P20
190 90
190 75
190 75
190 75
190 75
190 75
205 115
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
60
60
60
60
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
KRP5R800TM20
KRP5R1000TM20
KRP5R1200TM20
KRP5R1600TM20
KRP6R1000TM20
KRP6R1200TM20
KRP6R1600TM20
KRP6R2000TM20
KRP6R2500TM20
KRP6R3000TM20
KRP6R3500TM20
5P20
5P20
5P20
5P20
190
190
190
190
Page 48
75
75
75
75
HT
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.2.4 Protection - Resin Cast Ring Type - KSP Series
Part Number
KSP1R100QL5
KSP1R100SL5
KSP1R150RL10
KSP2R100SL5
KSP2R150RL10
KSP3R600TM10
KSP4R600TM10
KSP4R800TM10
KSP4R1000TM10
KSP4R1200TM10
KSP5R800TM10
KSP5R1200TM10
KSP5R1600TM10
KSP6R1000TM10
KSP6R1200TM10
KSP6R1600TM10
KSP6R2000TM10
KSP6R2500TM10
KSP6R3000TM10
Ratio
100/5 A
100/5 A
150/5 A
100/5 A
150/5 A
600/5 A
600/5 A
800/5 A
1000/5 A
1200/5 A
800/5 A
1200/5 A
1600/5 A
1000/5 A
1200/5 A
1600/5 A
2000/5 A
2500/5 A
3000/5 A
Burden
Class
ID OD HT
(VA)
5
10P5 30 100 65
10
10P5 30 125 75
7.5
10P10 30 125 75
10
10P5 45 140 75
7.5
10P10 45 140 75
15
5P10 55 125 75
15
5P10 70 140 75
15
5P10 70 140 75
15
5P10 70 175 40
15
5P10 70 140 75
15
5P10 85 175 40
15
5P10 85 175 40
15
5P10 85 175 40
15
5P10 115 190 85
15
5P10 115 190 85
15
5P10 115 190 85
15
5P10 115 190 85
15
5P10 115 190 85
15
5P10 115 190 85
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 49
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
5.3 Special Purpose
5.3.1 Summation Current Transformer
When the current in a number of feeders need not be individually metered but summated to
a single meter or instrument, a summation current transformer can be used. In consumer
installation, where there is more than one feeder, it is more economical to use summation
metering and for this purpose, summation Current Transformer (CT) is required.
The summation CT consists of two or more primary windings which are connected to the
feeders to be summated, and a single secondary winding which feeds a current proportional
to the summated primary current.
A typical ratio would be 5 + 5 + 5 / 5A, which means that three primary feeders of 5 Amps
are to be summated to a single 5 Amps meter.
We can custom-design to your specific requirements.
5.3.2 Interposing Current Transformer
Interposing types can be used to modify the secondary current from an existing line CT. This is
useful for modifying secondary currents without replacing the line CTs.
The main function of an interposing CT is to balance the currents supplied to the relay where
there would otherwise be an imbalance due to the ratios of the main CTs. Interposing CTs are
equipped with a wide range of taps that can be selected by the user to achieve the balance
required.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 50
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
As the name suggests, an interposing CT is installed between the secondary winding of the main
CT and the relay. They can be used on the primary side or secondary side of the power
transformer being protected, or both. Interposing CTs also provide a convenient method of
establishing a delta connection for the elimination of zero sequence currents where this is
necessary.
5.3.3 Core Balance Current Transformer
Core balance current transformers are intended for providing a very sensitive method of
earth leakage protection on three-phase electrical systems with suitable relays.
Cables of all phases pass through the inner diameter of the transformer and there is no
output under no-fault conditions. In the event of an earth-fault a non-zero current exist and
induces a changing magnetic field within the core, which in turn generates a secondary
voltage which operates a relay (via burden).
We can optimally custom-design to your specific requirements based on relay types and
settings, and the required primary operating current.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 51
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6 Medium Voltage Products
6.1 Monitoring Products
6.1.1 Cable Mounted Sensor
The LIQ60 is an intelligent transmission and distribution overhead line monitoring system
and can provide:



Continuous monitoring and capture of critical performance data on overhead network
lines up to 138kV;
Time-stamped event recordings;
Line status, fault waveform, outages, load profile, ambient and conductor
temperatures, voltage sensing, displacement power factor, voltage reading (with an
external insulated resistor);
Key features include:
 Maintenance-free
 Rapid installation for instant intelligence
 Intuitive software
 Flexible remote communications options
 SCADA protocol compatible
 Versatile applications
Key specifications include:
 Fault capture range: 1A - 25kA;
 Line frequency: 45Hz - 65Hz;
 Operating temperature: -40°C to +70°C;
 Ingress Protection: IP66;
 Housing material: UV stabilised polycarbonate;
 Dimensions: H: 315mm, D: 180mm, W: 140mm;
 Weight: 2kg;
 Battery powered and solar charged (2D movement 0.5W panel); and
 Includes 4 x 2V, 2.5Ah rechargeable (SLA batteries) and last approximately 45 days
without sunlight.
 Installation: Conductor range: 6mm to 32mm. No outage required. Easily installed on
energised lines using a hot stick.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 52
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.1.2 Pole Mounted Sensor
The LIQ35 is a reliable pole mounted solar powered line fault indicator (with battery backup)
for use on three phase three wire, and SWER overhead line systems. The LIQ35 utilises a
fault detection algorithm that adapts to network parameters and requires no configuration.
Key features include:
 Continuous fault indication;
 Fault types: Permanent faults; Transient faults; Outage events; Closure events; Selfclearing faults (fault current without loss of voltage);
 Patented adapting fault algorithm;
 Dual magnetic field sensors for improved fault capture;
 Voltage sensing to accurately identify outages and trips;
 Time and data stamped event recording;
 Recognition of line voltage return;
 Two visual indicators displaying line status and most recent fault;
 Inrush restraint to ensure only real faults are reported;
 SCADA protocol compatible (DNP3); and
 Advanced programmable options for maximum flexibility.
Key specifications include:
 Line voltage: 5kV to 145kV;
 Rechargeable batteries: 4 x 2V, 2.5Ah Sealed lead-acid
 Battery Life: up to 10 years;
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 53
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au









Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Solar panel: 3V, 1W;
Operation without solar (no active communications): 45 days;
Operating temperature: -40°C to +85°C;
Altitude: 1800m;
Local communications: 2.4GHz spread spectrum 50m range (line of sight);
Integrated remote communications: Embedded 3G cellular (PCI Express Mini Card);
Ambient temperature sensor (optional): -40°C to +85°C;
LED indicator – visibility (daylight / night time): 50m/50m;
Weight: 2.2kg;
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 54
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.2 Indoor and Outdoor Voltage Transformers
6.2.1 Indoor Single Phase Single Pole Voltage Transformers
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 55
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.2.2 Indoor Single Phase Double Pole Voltage and Control Transformers
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 56
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.2.3 Indoor Voltage Three Phase Voltage Transformers
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 57
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
Page 58
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.2.4 Draw-Out Voltage Transformers
6.2.5 Outdoor Voltage and Control Transformers
6.2.5.1.1
Oil Immersed Version
6.2.5.1.2
Cast Resin Version
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 59
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.2.6 Outdoor Metering Units
6.3 Indoor and Outdoor Current Transformers
6.3.1 Indoor Ring Type, Window Type and Bus Duct (up to 36kV)





Typically for currents of 200A and above - depending on burden and accuracy requirements.
Inner diameters from 65 mm to 170 mm available for ring type, and up to (110 x 75) mm for
window type.
Pigtail is provided for CTs of rating 6.6 kV and above, and should be connected to the primary
bar to obtain an equi-potential (discharge-free) connection.
Large diameter bus duct CTs are available, suitable for up to 30000 A.
Suitable for high short time ratings.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 60
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.3.2 Indoor Bar Primary Current Transformers (up to 36kV)
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 61
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.3.3 Indoor Wound Primary (block Type) Current Transformers (up to
36kV)
Suitable for current ratings up to 4000A:
 Primary connecting pad sizes vary depending upon primary current
 Standard frame widths of 148, 160, 180, 205, 240 mm
 Suitable for short time rating of 50 kA/3 seconds
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 62
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
6.3.4 Outdoor Current Transformers
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 63
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
7 Power Quality Mitigation Products
7.1 Reactors and Filters
We can source appropriate line side and load side reactors and filters to address the
identified causes of poor power quality.
7.2 Power Factor Correction Units
We work with local manufacturers and suppliers to provide appropriately sized PFC units.
We can custom design to your requirements and also offer a segregated design that not only
enables more efficient service and maintenance but also ensures the sensitive control
components are not affected by heat generated by the harmonic blocking reactors and
hence prolonging the life of the equipment.
Up to 100kVar Wall Mount Cubicle
1000H x 800W x 300D (wall mount cubicle without reactor segregation)
Up to 250kVar Cubicle
2000H x 800W x 600D (expandable to 300kVar if no isolator or circuit breaker required)
Up to 550kVar Cubicle
2000H x 1250W x 600D (expandable to 600kVar if no isolator or circuit breaker required)
Up to 800kVar Cubicle
2000H x 2050W x 600D (expandable to 900kVar if no isolator or circuit breaker required)
Up to 1000kVar Cubicle
2000H x 2500W x 600D
Switched Capacitor Bank:
Thyristor controlled switching technology - mitigates the effects of fast switching loads (lifts,
welding equipment, oil and gas drilling rigs; and mine site drilling equipment).
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 64
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
7.3 Active Harmonic Filtering
Wall-Mounted Active Filter ADF P100
The ADF P100 is an ultra-efficient, easy to use solution in a wall mounted cabinet. The tall
and narrow design allows installation where space is at a premium. It has a nominal current
of 70 to 100 A RMS and is available in the voltage range 208 - 480 V RMS nominal.
ADF P200 Active Filter
The ADF P200 is a very fast active filter and can eliminate harmonic problems up to the
100th harmonic and works well in even very resonant grids. It is suitable for mitigating
resonances, interharmonics and high frequency disturbances.
ADF P300 Active Filter
The ADF P300 is suitable for commercial and industrial loads.
STATCOM (Static Synchronous Compensator)
Is a shunt device, which uses force-commutated power electronics (i.e. GTO, IGBT) to
control power flow and improve transient stability on electrical power networks.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 65
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
ADF P700 STATCOM:
The ADF P700 is a high power, utility grade, medium voltage STATCOM for heavy industrial
loads. It is useful for dynamic reactive compensation, flicker mitigation, and harmonic
suppression in applications such as electric arc furnaces, cranes, hoists and wind farms.
The ADF P700 is available in modular 3 MVA or 6 MVA compensation power. Several units
can be operated in parallel to achieve higher power levels.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 66
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
8 Consulting and Services
8.1 Consulting in Power Quality
8.1.1 Power Quality Investigation
This includes:
 Site Survey
 Site Monitoring
 Data Analysis and Identification
 Reporting and Recommendations
8.1.2 Power Quality Mitigation
Following the Power Quality Investigation, we then propose solutions to mitigate the
contributing aspects to poor power quality. This includes proposing products and
equipment followed by further monitoring for validation.
8.1.3 Power Quality Management
Your electrical distribution system may be changing - growing (adding more elements
to do more work). In this case we would recommend a Power Quality Management
Plan for continuous monitoring and assessment.
8.2 Training
8.2.1 Product Training
Product training is provided on all electronic monitoring products and customised
equipment sold and or designed by CHK Power Quality Pty Ltd.
8.2.2 Professional Training
A single day course is offered in Power Quality with a certificate awarded upon
completion. The course covers an overview of power systems in Australia, introduces
concepts of power quality, monitoring and reporting and how to improve power
quality.
8.3 Technical Support
8.3.1 Product Support
Product support is provided on all electronic monitoring products and customised
equipment sold and or designed by CHK Power Quality Pty Ltd and some products
designed by GridSense; please enquire.
8.3.2 Calibration and Repairs
We have a service department that provide repairs and calibration for our electronic
products.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 67
Address: Unit 102, 25 Angas Street
Meadowbank NSW 2114, Sydney Australia
Website: www.chkpowerquality.com.au
Telephone:
Fax:
ABN:
+61 2 8283 6945
+61 2 8212 8105
53 169 840 831
8.4 Low Volume Contract Manufacturing
We have over fifteen years of experience in low volume production. Items include:
wire looms; leads and probes; building electronic circuit boards (hand soldering) and
product sub-assemblies.
8.5 Engineering and Project Management Services
8.5.1 Feature Requests and New Features
Where possible, we can update a product to include a specific feature to address
your requirement.
8.5.2 Design
Our engineering team can custom-design a solution (involving industrial design,
electronic, firmware and software development) and manage the whole product
development cycle, from specification to testing and approvals.
PRODUCTS AND SERVICES CATALOGUE - 10 FEB 2015.
Enquiries: (Mob): 0402 537 678; sales@chkpowerquality.com.au
Page 68
Download PDF