UNIFLEX-R / REX
3
4
7
8
2 -wire Temperature transmitter
programmable
100
90
UNIFLEX
80
70
60
50
Pt100, Ni 100, Cu 100
40
30
Thermo couple type J, K, L, N, R, S, B
20
10
0
1
Setting via PC
Ex protection EEx ia II C T5
2
Bargraph-display scalable
GENERAL
The UNIFLEX 2-wire temperature
transmitter with bargraph display is the
solution to requirements regarding
flexibility, reduced stock as approved
safety against electromagnetic
interferences.
By means of a PC and a programming
set the transmitter is programmed for
sensor type, measuring and display
range.
For use within hazardous areas an
intrinsically safe version is available.
DESCRIPTION
The transmitter consists of two
independent signal inputs. One for
thermocouples and one for resistive
temperature sensors.
If thermocouple is selected, the resistive
input is beeing used for connection of
the cold junction compensation sensor
Pt100CJC.
Resistive sensors can be connected in
3-wire configuration.
The bargraph display will be adjusted
within the choosen span to perform
optimal display function.
TECHNICAL DATA
Load
R Load =
INPUT
Resolution 14 bit (16 384 steps)
Resistance transducer
Sensor
span °C
Pt100
-50...+450
Ni100
-50...+200
Cu100
-50...+200
min. span
error
20 [K]
0.25 (K)
Smallest configurable resolution: 0.1 K
RTD current: < 0.2 mA, pulsating
Configuration: 3-wire
max. lead resistance ≤10 Ω per lead
Thermocouple
Type
spane °C
J
-50...+800
L
-50...+800
K
-50...1250
N
-50...1200
R
.50...1700
S
.50...1700
B
+600...1800
min. span
error
50 [K]
1 [K]
200 [K]
2 [K]
Smallest configurable resolution: 0.1 K
Cold junction compensation
with Pt100 at terminals 3 + 4 (+7);
2-/ 3-wire connection, error 0.1K/10K
OUTPUT
Standard signal: 4...20 mA
Resolution: 12 bit
U Supply − 6.5[V ]
0.02[A]
− R Lead
Output current limitation:appr.3.8/22 mA
Characteristic: temperature linear
Conformity error: ± 0.1 % of span
Accuracy
(inclusive linearity error)
Sensor
error
Pt100
Ni100
Cu100
± 0.25 K ± 0.1 % of span
TypJ
Typ L
Typ K
± 1 K ± 0.15 % of span
Typ R
Typ S
Typ B
± 2 K ± 0.15 % of span
Response time
T90 RTD ≤ 0.5 s
TC ≤ 0.6 s
Sensor break
upscale (22 mA) for RTD and TC
DISPLAY
Bargraph 51 segments with a resolution
of 2 % for each visible element, respective 1 %, when top segment flashes.
The display is selectable within the
measuring range.
E.g.:
Output signal: 4 mA = 0 °C, 20 mA = 600 °C
Display: 0% = 500 °C, 100 % = 600 °C
POWER SUPPLY
GENERAL
ORDER CODES
Supply voltage: 6.5...35 VDC
EEx 6.5...28 VDC
Dimensions: 62 x 88 x 24 mm
Mode of protection: housing IP30,
terminals IP10
Description
Electrical connection: screw terminals
Weight: 0.12 kg
Mounting: 35 mm rail to DIN 46 277
Configured to specification
Power supply effect
To span start: ≤ ± 0.005 % / V
to span: ≤ ± 0.001 % / V
Permissable ripple: 3 Vrms
Supply voltage failure
for measurement / zur Messung
for compensation / zur Kompensation
Pt100
ENVIRONMENTAL CONDITIONS
Temperature limits
_
Operation: -10 ... + 60 °C
Storage: -35 ... + 85 °C
4
7
8
+
100
90
80
70
Vibrations: 0.7 g 10 to 100 Hz
(Lloyds Register Test 1)
60
50
40
30
Temperature effect: <± 0.1 % / 10 K
20
10
0
Long term drift: ± 0.1 % / 10 000 h
ELECTROMAGNETIC
COMPATIBILITY
1
9404-202-08001
1)
9404-202-08001
UNIFLEX REX (EEx)
Not configured
9404-202-08051
1)
9404-202-08061
ACCESSORIES
Description
3
Humidity: 90 % RH, no condensation
Not configured
Configured to specification
Fig. 3 Connections
no loss of configuration datas
Order number
UNIFLEX R
2
Order number
Measuring resistor for internal
temperature compensation with
Thermocouple measurements
9404-202-08311
Programming set
Adapter for connection to serial
interface of a PC.
The programming set comprises:
Programming unit with cable and
25-pin sub-D conector.
3 ½-inch program disk
Battery connector and connecting
lead. Operating instructions.
9404-202-09301
Transmitter supply units
230 VAC, standard
9404-202-08231
230 VAC, HRT, 70 mA
115 VAC, HRT, 70 mA
9404-202-08401
9404-202-08421
Ex proof power supply units
Tested to EN 50082-2 and EN 50081- 1/2
EXPLOSION PROTECTION
+ 4...20 mA
1)
Clear text order information
Sensor...........; Temp.Compensation.....
Mounting position
not critical (check display)
Conforms to EN 50 014 and 50 020
EEx ia IIC T5
See separate data
sheet TPS HART
Span start
(4mA)
.......°C
Certificate of conformity
Span end
20 mA
Display start
(0 %)
Display end
(100 %)
.......°C
.......°C
.......°C
DEMKO 94D.116789X
Fig. Dimensions
Fig. 2 Access to information
40
How to open ?
Wie öffnen ?
Comment ouvrir ?
INFO
b)
62
65,5
a)
INFO
88
24
Deutschland
PMA Prozeß- und Maschinen- Automation GmbH
Miramstrasse 87, D-34123 Kassel
Your local distributor
Tel./Fax: (0561) 505 - 1307/-1710
E-mail: mailbox@pma-online.de
Internet: http://www.pma-online.de
Printed in Germany - Edition 0103 - Subject to alterations - 9498 737 23713
Download PDF