Large-capacity
Uninterruptible Power System (UPS)
20 to 320 kVA
All IGBT type UPS 7000F Series
REC 82-5
Fuji's UPS for today's computerized
On-line support for all applications
Data communication devices and computers
constitute the backbone of society today and
so require utmost reliability. First and foremost,
a stable power supply without momentary
failures is indispensable. Fuji Electric
dominates the market for UPS which protect
such devices and systems against power
failures and disturbances.
The Fuji UPS 7000F series features the latest in
power electronics, systems, digitization and
high-frequency switching. It also offers
outstanding load matching and suppression of
harmonic currents commonly found in
electronic devices.
UPS: Uninterruptible Power System
Internet data center
Financial institutions (banks, insurance
companies, securities firms)
Public services (satellites, broadcasting,
media, telecommunications)
Totalizer systems (horse races, cycle races)
Traffic control systems (aviation, railroad,
automobile)
Plants (power, chemical, etc.)
New media (VAN, INS, etc.)
Other (information processing services,
medical systems, etc.)
1
world
UPS 7000F Series
Features
All IGBT type UPS
High performance
PWM rectifier
• Uninterruptible feed by all-time inverter type
• High input power factor: 0.98 or higher (almost 1.0)
• Wide range of input voltage: 380V –20 to +15%
• Low input harmonic content: 4% or less (needs no
• Overload capacity: 125% for 10min , 150% for 10s
external filter)
• Power walk-in function provided as standard (soft shift
of load to emergency generator)
High reliability
• Fewer parts thanks to latest devices
• Screening test, burn-in test, high quality control
High-frequency PWM inverter
• High quality backed by strong track record
• Performance optimum for computer load.
Long-life battery as standard
Under rectifier load, the waveform distortion is small
• The standard rectifier can charge a long-life battery.
(below 3.5%), and the transient voltage variation is also
Can be used for many types of system
small.
• Synchronized and uninterrupted switching with bypass
Efficiency of 91% or more
• Standby redundancy system
• Latest IGBTs
• Parallel redundancy system (N = 8)
• Latest circuit design
• Battery control function (automatic deterioration
diagnosis, replacement advance notice indication)
• Guidance function
Registration No.
: EC97J1061
Date of registration : August 26, 1997
Kobe Works, where this instrument is manufactured,
is certified by ISO 14001 environmental compliance.
2
Full protection from power disturbances
(Input voltage waveform)
Frequency
Voltage
variation
Momentary
voltage drop
Waveform
distortion
Voltage
Noise
Constant-voltage
constant-frequency
(CVCF)
Power variation
Frequency
variation
Momentary
interruption
Power failure
Accidental
power failure
Commercial power input
UPS
Output voltage waveform
High reliability and high performance proven by track record
High performance by high-speed switching
High-performance IGBTs (Insulated Gate Bipolar Transistors)
achieve higher frequency switching and larger current
characteristics than conventional bipolar transistors, and are
the next-generation IGBTs.
High reliability ensured by IGBT power module
High reliability and maintainability are essential for IGBT
power modules in particular. On the module, therefore,
IGBTs, fuses, drive circuitry, etc. are integrated, and a large
current substrate is adopted for wiring, thereby assuring high
reliability.
DK10781-2
Innovation by all-digital control
All-digital design by latest control processor
The all-digital design with high-performance processor, DSP
(Digital Signal Processor), RISC (Reduced Instruction Set
Computer) and ASIC (Application Specified IC) has allowed
the number of parts to be considerably reduced, thereby
enhancing reliability.
High reliability ensured by separating the
control section and monitoring section
The reliability is enhanced by separating the control section
and monitoring section, and designing the monitoring section
in double systems, software and hardware.
3
N99-2458-4a
All IGBT type UPS
PWM rectifier
PWM inverter
PWM rectifier
PWM inverter
Suppresses input harmonic currents
Always clean sinusoidal voltage
The momentary waveform control function controls the
rectifier input current to be sinusoidal at all times, thereby
suppressing adverse effects on emergency private
generators or power capacitors.
Fuji's own digital instantaneous
waveform control outputs a
voltage of a clean sinusoidal
waveform even under rectifier
load such as computer load.
AC output voltage (rectifier load current)
Output voltage
Load current
Higher input power factor
The power factor of the input
power for the rectifier is controlled
to 1.0. Therefore, reactive power
disappears, thereby reducing the
input power.
DK7518
Input voltage and current waveforms
Output voltage free from excessive transient variations
Input current
Input voltage
The output voltage remains
almost unchanged even when the
load abruptly changes from 0 to
100% or vice-versa.
Output voltage waveform
(at abrupt 100% change in load)
Output voltage
Output current
DK7520
Shock-less operation of input power
The operation is shock-less thanks to power walk-in control
(at UPS starting, turning-on of private generator, power
recovery, etc.)
Operation of PWM converter
The voltage on the PWM rectifier side is controlled so that
the input
current will be
sinusoidal and
in phase with
the input
voltage.
PWM rectifier
Ii
Input
power
DK4908-1
Voltage is balanced even when the load is
unbalanced between phases
Distinct control of three voltage phases ensures that the
voltage is balanced even when the load is unbalanced
between phases.
Suppresses the voltage variation at bypass switching
VL=jXL Ii
Vi
Soft shift of load allows
switching with bypass, free
from excessive voltage
variations.
Vrec
Input power
Vi
Ii
VL=jXL Ii
Vrec
Output voltage waveform
(switched to through feed under 100% of load)
Inverter volt.
Inverter volt.,
through volt.
mixed
Through
volt.
UPS
output
voltage
UPS
output
current
Through
current
Inverter
output
current
4
High reliability and high performance with perfect
DDC control
Fewer parts improves reliability
Powerful self-diagnostic function
Sophisticated control, such as momentary value
prediction
Communication, indication, guidance, failure log,
event information provided as standard
Digital adjustment minimizes influences of secular
change or temperature variation
The latest control devices (processor, DSP,
RISC, ASIC, etc.) and control techniques
combine to deliver ideal UPS performance.
PWM rectifier
PWM inverter
Battery
ASIC
(PWM signal)
DSP
(control)
ASIC
(monitoring)
(Measurement and command)
RISC
(monitoring)
Monitor
5
MPU
(man-machine)
Character display
LCD
High-reliability power system
System of synchronized and uninterrupted switching with bypass
Fault
All time
Rectifier
Output
Inverter
AC input
UPS
Output
Bypass
Battery
At fault, maintenance, overcurrent
Load voltage
(output)
AC switch
Bypass
Standby redundancy system
All time
Rectifier
Inverter
AC input
Main UPS
Output
Main UPS
Battery
AC
switch
Fault
Standby UPS
At fault, maintenance
Rectifier
Fault
Bypass
Load voltage
(output)
Inverter
AC input
Standby UPS
Output
Battery
At fault of 2 units, overcurrent
AC
switch
Bypass
Parallel redundancy system
All time/opposite (at fault, maintenance)
Input TR
Rectifier
Output bus/switchgear
Inverter
AC input
No.1UPS
Fault
No.1UPS
Battery
At fault of 2 units, overcurrent
AC
switch
Bypass
No.2UPS
Output
All time/opposite (at fault, maintenance)
Input TR
Rectifier
Inverter
AC input
No.2UPS
Fault
Bypass
Load voltage
(output)
Battery
At fault of 2 units, overcurrent
AC
switch
Bypass
6
Rated specifications
3/30
3/50
3/80
3/100
3/160
3/20
30/24
50/40
80/64
100/80
160/128
20/16
Inverter power supply at all times
Synchronized and uninterrupted switching with bypass
380
–20% to +15% (304 to 437V)
50
±5%
3-phase, 4-wire
5% max.
0.98 min. (at rated operation)
380
50
3-phase, 4-wire
396V (lead-acid battery, 198 cells)
336.6 to 455.4V
3-phase, 4-wire
380
50
0.7 (lag) to 1.0 (rated value: 0.8 lag)
45.6
76
121.6
151.9
243.1
30.4
±1%
(1) ±5%: at abrupt load change from 0 to 100% or vice-versa
(2) ±2%: at abrupt ±10% change of input voltage
(3) ±2%: at failure/recovery of commercial power
(4) ±5%: at switching from UPS to bypass or vice-versa (at rated bypass voltage)
Settling time
50ms max.
Harmonic distortion
3% max. (under 100% linear load), 5% max. (under 100% rectifier load)
±3% (under 100% unbalanced load)
Voltage unbalance
Frequency accuracy
0.01% (for internal oscillation)
External synchronization range ±1% (at bypass synchronization)
Overload capacity
125% for 10min, 150% for 10s
±5% (under rated load)
Voltage adjustable range
–10 to +40˚C (operating), +18 to +27˚C (recommended)
Ambient temperature
Relative humidity
30 to 90% (no condensation)
3
5
7
8
13
Heat loss
[kW] 2
Altitude
1000m max.
Communication interface
RS-232C, SNMP (option)
UPS7000F–
Type
[kVA/kW]
Rated capacity
Power supply system
Bypass
Rated voltage
[V]
Input
Voltage variation range
Rated frequency
[Hz]
Frequency variation range
No. of phases and wires
Harmonic current
Power factor
Rated voltage
[V]
Bypass
Rated frequency
[Hz]
No. of phases and wires
Nominal DC voltage
DC voltage variation range
No. of phases and wires
Output
Rated voltage
[V]
Rated frequency
[Hz]
Load power factor
Rated current
[A]
Voltage accuracy (at settling)
Transient voltage variation
Others
3/200
200/160
3/240
240/192
3/320
320/256
303.9
364.7
486.2
16
20
25
External dimensions
UPS dimensions
Dimensions
W
500
500
600
600
650
1200
2000
2400
2800
Front view
[mm] Mass
D
800
800
1000
1000
1000
1000
1000
1000
1000
H
1150
1150
1625
1625
1950
1950
1950
1950
1950
Side view
[kg]
Air outlet
270
300
440
500
800
1250
2000
2200
2800
H
Capacity
[kVA]
20
30
50
80
100
160
200
240
320
Air inlet
Note: Dimensions given are per system of synchronized and uninterruptible
switching with bypass.
W
D
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
Phone : (03)3515-7500
Internet address : http://www.fesys.co.jp
Information in this catalog is subject to change without notice.