Important Notes Regarding your
wall mount installation
When installing a Great Lakes wall-mounted rack enclosure to materials such as wood, cinder
block, concrete, etc., please consider the load capacity within the wall mount structure, and be
certain to check with local authorities to determine the appropriate hardware requirements for
these conditions. Because wall compositions may vary at different installation sites, Great Lakes
cannot warrant the fitness or suitability of any installation instructions or installation hardware
it may provide for wall-mount rack enclosures. Great Lakes recommends that an experienced
maintenance and/or technical person be consulted regarding the proper wall-mounting hardware
and procedures to be used for the anticipated load capacity of the wall-mounted rack enclosure.
Maximum weight capacity determined at minimal deflection. (Deflection chart available upon
request.)Make sure enclosure is secured and squared on mounting surface. Improper installation
will cause excessive deflection.
WS Series Wall MOunt/
SWing Out Enclosure
1. Mounting holes are designed for 1/4"hardware, 16" on center.
2. Use the template on the shipping box to locate your mounting holes.(WM & WS only)
3. WS and WD handles can be found in the hardware bag.
1", 2", 3" and 4" nominal
concentric conduit knockouts
24"
Part No. HWD
GL24WS 24.00" 24.00" 24.00"
GL36WS 36.00" 24.00" 24.00"
GL48WS 48.00" 24.00" 24.00"
Fan assembly
provisions
Optional caster
mounting holes
24"
Two pair 19" EIA rails
provided with each enclosure
Mounting holes for 1/4"
hardware, 16.00" centers
Side View
PART NO. DESCRIPTIONWMWSWDWE
3
DK2*
Dust Resistant Kit,
q
q
q
q
4 cover plates, 4 fan filters
and hardware
3
3
3
FFK1 Four Fan Filters q
q
q
q
HDW-104-50 Package of 50 Pan Head Phillips #12-24 x 1/2"
screws Type 23, Black
3
q
3
q
3
q
q
WS-22
66/110 Block Mounting Panel
3
q
3
q
3
q
3
q
* Will not fit GL2418WM
When installing a Great Lakes wall-mounted rack enclosure to materials such as
wood, cinder block, concrete, etc., please consider the load capacity within the
wall mount structure, and be certain to check with local authorities to determine
the appropriate hardware requirements for these conditions. Because wall
compositions may vary at different installation sites, Great Lakes cannot warrant
the fitness or suitability of any installation instructions or installation hardware
it may provide for wall-mount rack enclosures. Great Lakes hereby DISCLAIMS
ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, REGARDING THE SUFFICIENCY, FITNESS OR SUITABILITY OF ANY
INSTALLATION INSTRUCTIONS OR INSTALLATION HARDWARE GREAT LAKES
MAY PROVIDE FOR WALL-MOUNTED ENCLOSURES. Great Lakes recommends
that an experienced maintenance and/or technical person be consulted
regarding the proper wall-mounting hardware and procedures to be used for the
anticipated load capacity of the wall-mounted rack enclosure.
Product specifications are subject to change without prior notice.
Great Lakes Case & Cabinet Co., Inc.
P.O. Box 551 • Edinboro, PA 16412
1-866-TRY-GLCC • (1-866-879-4522)
Phone: 814.734.7303
Fax: 814.734.3907
H
Side View
Wall Mount AcCESSORIES
Front View
Rear View
Wall Mount AcCESSORIES
PART NO. DESCRIPTIONWMWSWDWE
3
3
3
7206-FM* Stationary Front Mount Shelf
q
q
q
q
18.00"D, Weight Cap. 60 lbs.
3
3
3
7206-EIA* Stationary Shelf
q
q
q
q
18.00"D, Weight Cap. 80 lbs.
3
3
7206-14 Stationary Shelf
q
q
q
q
14.00"D, Weight Cap. 60 lbs.
3
3
3
7206-FR-A18* Stationary Shelf q
q
q
q
front & rear mount, adjustable
18.00"D, Weight Cap. 150 lbs.
3
7206-FR-AHD Stationary Shelf q
q
q
q
front & rear mount, adjustable
22.25"D, Weight Cap. 200 lbs.
3
3
3
7206-SL*
Sliding Shelf
q
q
q
q
16.343"W x 17.50"D
Weight Cap. 40 lbs.
3
7206-FRSL-AHD Sliding Shelf
q
q
q
q
front & rear mount sliding, (adj.)
22.00"D, Weight Cap. 110 lbs.
3
3
3
3
7219 6 position Power Strip
q
q
q
q
15 ft. cord for 19" mounting
3
3
3
3
7219-SR14
Rack mount 14 position
q
q
q
q
(6 front/8 back) Power Strip
with surge suppressor
3
3
3
3
7219-20AR
6 position Power Strip
q
q
q
q
with curcuit breaker (20 amp)
3
3
3
3
7217WS Fan Assembly with fan guards q
q
q
q
and (2) 75 CFM fans
3
3
7208WS/WD Casters, 3 locking and q
q
q
q
3 non-locking, 3.625"H
3
3
3
3
CBB-19 Copper Bus Bar 19" q
q
q
q
rack mounted (isolated)
3
3
3
GR102
Grounding Kit
q
q
q
q
WM Series Wall MOunt
Enclosure
1. Mounting holes are designed for 1/4" hardware, 16.00" on center.
2. Use the template on the shipping box to locate your mounting holes.(WM & WS only)
Rear section
Option: 2, Fan unit ventilation
top or bottom mounting
1", 2" and 3" nominal
concentric conduit
knockouts and horseshoe
knockouts; top & bottom
rear section
Center swing section
19" EIA Rack spaced
2 pair mounting rails
tapped #12-24
Continuous Hinges on
front door & rear section
Independent locking front
door & rear section
Front door
6
Part No.
GL2418WM
GL24WM
GL36WM
GL48WM
HWD
24.00"
21.25"
18.00"
24.00" 21.25" 24.50"
36.00"
21.25"
24.50"
48.00"
21.25"
24.50"
5
4
3
DK1 Dust Resistant Kit,
4 cover plates, 4 fan filters
and hardware q
q
1
D
C
C
B
B
DETAIL B
DETAIL A
Front View
Use latch supplied in hardware bag,
when horseshoe knockout is used
INTERPRET DRAWING PER ASME Y14.5M-1994
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
A
Keyhole
Mounting
DRAWING NOT TO SCALE
TOLERANCE UNLESS OTHERWISE NOTED:
ANGULAR +/- 1~
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
1", 2" and 3" rear section nominal
concentric conduit knockout
THIRD ANGLE
PROJECTION
6
5
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
4
21.25
10.63
"A"
H
"A"
q
D
W
"B"
5.00
"C"
"B"
"B"
"C"
"C"
5.00
5.00
Top/Bottom View
A
P.O. BOX 551 EDINBORO, PA 16412
PHONE (814) 734-7303 FAX (814) 734-3907
E-MAIL glcc@greatcabinets.com
REV
SHEET: 1 OF 1
2
1
1", 2" and
3" rear section
21.25
2.50
nominal concentric
conduit
10.63
knockout and horseshoe knockout
10.63
16.00
18.31
21.25
GREAT LAKES CASE & CABINET CO., INC.
DATE
10.63
Side Ventilation
16.00
CHECKED & APP.
TITLE
DWG NO:
21.25
10.63
16.00 18.31
18.3121.25
21.25
PART NUMBER:
3
Side View
10.63
NOTICE:
cable latch detail
Use of this document is subject to
QTY PER UNIT:
1
MATERIAL TYPE:
a confidentiality and nondisclosure
agreement with Great Lakes Case
MATERIAL GAUGE:
& Cabinet Co., Inc. (GLCC) and may
FINISH:
not be reproduced, disclosed or
utilized in whole or in part without
DRAWN
DATE
10/5/2007
prior written authorization from GLCC. ANDY
"A"
3
q
2
D
2.50
Note: 2 Fan unit
mounting shown
for GL24WM,
GL36WM, and
GL48WM. Fan
unit mounting rotated 90
degrees on
GL2418WM.
2.
ULDER
WD Series Wall MOunt
Enclosure
1.
2.
3.
WE Series Wall MOunt
Enclosure
Mounting holes are designed for 1/4" hardware, 16.00" on center.
See detail “B” to remove pins for mounting back section to the wall
(make sure to reinstall back pin after wall mounting)
WS and WD handles can be found in the hardware bag.
1. Mounting holes are designed for 1/4" hardware, 16.00" on center.
2. Wall Mount must be mounted to three wall studs to achieve
maximum weight capacity.
4
3
Front View
2
Mesh Doors with
lock (quantity 2)
D
Side View
C
Top/Bottom View
1", 2", 3" and 4"
rear section nominal
concentric conduit
knockout
Rear View
Fan Assembly Provision (7217WS)
B
1", 2" and 3"
nominal concentric
conduit knockout;
Typ. 3 top & bottom
Typ. 3 rear
B
Mounting holes
for 1/4" hardware
Detail B
1", 2", 3" and 4" nominal
concentric conduit
knockout
Fan knockouts for
7217Ws assembly
located on top
and bottom
B
INTERPRET DRAWING PER ASME Y14.5M-1994
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
A
DRAWING NOT TO SCALE
TOLERANCE UNLESS OTHERWISE NOTED:
ANGULAR +/- 1~
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
Top View
DETAIL B
SCALE 1
THIRD ANGLE
PROJECTION
DETAIL B
SCALE 1
CENTER
SWING
SECTION
LOCK PIN SCREW
3
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
PART NUMBER:
CHECKED & APP.
2
LOCK PIN SCREW
LOCK PIN BRACKET
REAR SECTION
LOCK PIN BRACKET
4
NOTICE:
I003909 catalog2
Use of this document is subject to
QTY PER UNIT:
1
MATERIAL TYPE:
a confidentiality and nondisclosure
agreement with Great Lakes Case
MATERIAL GAUGE:
& Cabinet Co., Inc. (GLCC) and may
FINISH:
not be reproduced, disclosed or
utilized in whole or in part without
DRAWN
DATE
4/19/2006
prior written authorization from GLCC. JAL
NYLON SHOULDER
WASHER
REAR SECTION
SUPPORT PLATE
HINGE PIN
Rear View
DATE
TITLE
24"H x
GREAT L
PHO
DWG NO:
ULDER
WD Series Wall MOunt
Enclosure
1.
2.
3.
WE Series Wall MOunt
Enclosure
Mounting holes are designed for 1/4" hardware, 16.00" on center.
See detail “B” to remove pins for mounting back section to the wall
(make sure to reinstall back pin after wall mounting)
WS and WD handles can be found in the hardware bag.
1. Mounting holes are designed for 1/4" hardware, 16.00" on center.
2. Wall Mount must be mounted to three wall studs to achieve
maximum weight capacity.
4
3
Front View
2
Mesh Doors with
lock (quantity 2)
D
Side View
C
Top/Bottom View
1", 2", 3" and 4"
rear section nominal
concentric conduit
knockout
Rear View
Fan Assembly Provision (7217WS)
B
1", 2" and 3"
nominal concentric
conduit knockout;
Typ. 3 top & bottom
Typ. 3 rear
B
Mounting holes
for 1/4" hardware
Detail B
1", 2", 3" and 4" nominal
concentric conduit
knockout
Fan knockouts for
7217Ws assembly
located on top
and bottom
B
INTERPRET DRAWING PER ASME Y14.5M-1994
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
A
DRAWING NOT TO SCALE
TOLERANCE UNLESS OTHERWISE NOTED:
ANGULAR +/- 1~
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
Top View
DETAIL B
SCALE 1
THIRD ANGLE
PROJECTION
DETAIL B
SCALE 1
CENTER
SWING
SECTION
LOCK PIN SCREW
3
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
PART NUMBER:
CHECKED & APP.
2
LOCK PIN SCREW
LOCK PIN BRACKET
REAR SECTION
LOCK PIN BRACKET
4
NOTICE:
I003909 catalog2
Use of this document is subject to
QTY PER UNIT:
1
MATERIAL TYPE:
a confidentiality and nondisclosure
agreement with Great Lakes Case
MATERIAL GAUGE:
& Cabinet Co., Inc. (GLCC) and may
FINISH:
not be reproduced, disclosed or
utilized in whole or in part without
DRAWN
DATE
4/19/2006
prior written authorization from GLCC. JAL
NYLON SHOULDER
WASHER
REAR SECTION
SUPPORT PLATE
HINGE PIN
Rear View
DATE
TITLE
24"H x
GREAT L
PHO
DWG NO:
Wall Mount AcCESSORIES
PART NO. DESCRIPTIONWMWSWDWE
3
3
3
7206-FM* Stationary Front Mount Shelf
q
q
q
q
18.00"D, Weight Cap. 60 lbs.
3
3
3
7206-EIA* Stationary Shelf
q
q
q
q
18.00"D, Weight Cap. 80 lbs.
3
3
7206-14 Stationary Shelf
q
q
q
q
14.00"D, Weight Cap. 60 lbs.
3
3
3
7206-FR-A18* Stationary Shelf q
q
q
q
front & rear mount, adjustable
18.00"D, Weight Cap. 150 lbs.
3
7206-FR-AHD Stationary Shelf q
q
q
q
front & rear mount, adjustable
22.25"D, Weight Cap. 200 lbs.
3
3
3
7206-SL*
Sliding Shelf
q
q
q
q
16.343"W x 17.50"D
Weight Cap. 40 lbs.
3
7206-FRSL-AHD Sliding Shelf
q
q
q
q
front & rear mount sliding, (adj.)
22.00"D, Weight Cap. 110 lbs.
3
3
3
3
7219 6 position Power Strip
q
q
q
q
15 ft. cord for 19" mounting
3
3
3
3
7219-SR14
Rack mount 14 position
q
q
q
q
(6 front/8 back) Power Strip
with surge suppressor
3
3
3
3
7219-20AR
6 position Power Strip
q
q
q
q
with curcuit breaker (20 amp)
3
3
3
3
7217WS Fan Assembly with fan guards q
q
q
q
and (2) 75 CFM fans
3
3
7208WS/WD Casters, 3 locking and q
q
q
q
3 non-locking, 3.625"H
3
3
3
3
CBB-19 Copper Bus Bar 19" q
q
q
q
rack mounted (isolated)
3
3
3
GR102
Grounding Kit
q
q
q
q
WM Series Wall MOunt
Enclosure
1. Mounting holes are designed for 1/4" hardware, 16.00" on center.
2. Use the template on the shipping box to locate your mounting holes.(WM & WS only)
Rear section
Option: 2, Fan unit ventilation
top or bottom mounting
1", 2" and 3" nominal
concentric conduit
knockouts and horseshoe
knockouts; top & bottom
rear section
Center swing section
19" EIA Rack spaced
2 pair mounting rails
tapped #12-24
Continuous Hinges on
front door & rear section
Independent locking front
door & rear section
Front door
6
Part No.
GL2418WM
GL24WM
GL36WM
GL48WM
HWD
24.00"
21.25"
18.00"
24.00" 21.25" 24.50"
36.00"
21.25"
24.50"
48.00"
21.25"
24.50"
5
4
3
DK1 Dust Resistant Kit,
4 cover plates, 4 fan filters
and hardware q
q
1
D
C
C
B
B
DETAIL B
DETAIL A
Front View
Use latch supplied in hardware bag,
when horseshoe knockout is used
INTERPRET DRAWING PER ASME Y14.5M-1994
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
A
Keyhole
Mounting
DRAWING NOT TO SCALE
TOLERANCE UNLESS OTHERWISE NOTED:
ANGULAR +/- 1~
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
1", 2" and 3" rear section nominal
concentric conduit knockout
THIRD ANGLE
PROJECTION
6
5
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
4
21.25
10.63
"A"
H
"A"
q
D
W
"B"
5.00
"C"
"B"
"B"
"C"
"C"
5.00
5.00
Top/Bottom View
A
P.O. BOX 551 EDINBORO, PA 16412
PHONE (814) 734-7303 FAX (814) 734-3907
E-MAIL glcc@greatcabinets.com
REV
SHEET: 1 OF 1
2
1
1", 2" and
3" rear section
21.25
2.50
nominal concentric
conduit
10.63
knockout and horseshoe knockout
10.63
16.00
18.31
21.25
GREAT LAKES CASE & CABINET CO., INC.
DATE
10.63
Side Ventilation
16.00
CHECKED & APP.
TITLE
DWG NO:
21.25
10.63
16.00 18.31
18.3121.25
21.25
PART NUMBER:
3
Side View
10.63
NOTICE:
cable latch detail
Use of this document is subject to
QTY PER UNIT:
1
MATERIAL TYPE:
a confidentiality and nondisclosure
agreement with Great Lakes Case
MATERIAL GAUGE:
& Cabinet Co., Inc. (GLCC) and may
FINISH:
not be reproduced, disclosed or
utilized in whole or in part without
DRAWN
DATE
10/5/2007
prior written authorization from GLCC. ANDY
"A"
3
q
2
D
2.50
Note: 2 Fan unit
mounting shown
for GL24WM,
GL36WM, and
GL48WM. Fan
unit mounting rotated 90
degrees on
GL2418WM.
2.
Important Notes Regarding your
wall mount installation
When installing a Great Lakes wall-mounted rack enclosure to materials such as wood, cinder
block, concrete, etc., please consider the load capacity within the wall mount structure, and be
certain to check with local authorities to determine the appropriate hardware requirements for
these conditions. Because wall compositions may vary at different installation sites, Great Lakes
cannot warrant the fitness or suitability of any installation instructions or installation hardware
it may provide for wall-mount rack enclosures. Great Lakes recommends that an experienced
maintenance and/or technical person be consulted regarding the proper wall-mounting hardware
and procedures to be used for the anticipated load capacity of the wall-mounted rack enclosure.
Maximum weight capacity determined at minimal deflection. (Deflection chart available upon
request.)Make sure enclosure is secured and squared on mounting surface. Improper installation
will cause excessive deflection.
WS Series Wall MOunt/
SWing Out Enclosure
1. Mounting holes are designed for 1/4"hardware, 16" on center.
2. Use the template on the shipping box to locate your mounting holes.(WM & WS only)
3. WS and WD handles can be found in the hardware bag.
1", 2", 3" and 4" nominal
concentric conduit knockouts
24"
Part No. HWD
GL24WS 24.00" 24.00" 24.00"
GL36WS 36.00" 24.00" 24.00"
GL48WS 48.00" 24.00" 24.00"
Fan assembly
provisions
Optional caster
mounting holes
24"
Two pair 19" EIA rails
provided with each enclosure
Mounting holes for 1/4"
hardware, 16.00" centers
Side View
PART NO. DESCRIPTIONWMWSWDWE
3
DK2*
Dust Resistant Kit,
q
q
q
q
4 cover plates, 4 fan filters
and hardware
3
3
3
FFK1 Four Fan Filters q
q
q
q
HDW-104-50 Package of 50 Pan Head Phillips #12-24 x 1/2"
screws Type 23, Black
3
q
3
q
3
q
q
WS-22
66/110 Block Mounting Panel
3
q
3
q
3
q
3
q
* Will not fit GL2418WM
When installing a Great Lakes wall-mounted rack enclosure to materials such as
wood, cinder block, concrete, etc., please consider the load capacity within the
wall mount structure, and be certain to check with local authorities to determine
the appropriate hardware requirements for these conditions. Because wall
compositions may vary at different installation sites, Great Lakes cannot warrant
the fitness or suitability of any installation instructions or installation hardware
it may provide for wall-mount rack enclosures. Great Lakes hereby DISCLAIMS
ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, REGARDING THE SUFFICIENCY, FITNESS OR SUITABILITY OF ANY
INSTALLATION INSTRUCTIONS OR INSTALLATION HARDWARE GREAT LAKES
MAY PROVIDE FOR WALL-MOUNTED ENCLOSURES. Great Lakes recommends
that an experienced maintenance and/or technical person be consulted
regarding the proper wall-mounting hardware and procedures to be used for the
anticipated load capacity of the wall-mounted rack enclosure.
Product specifications are subject to change without prior notice.
Great Lakes Case & Cabinet Co., Inc.
P.O. Box 551 • Edinboro, PA 16412
1-866-TRY-GLCC • (1-866-879-4522)
Phone: 814.734.7303
Fax: 814.734.3907
H
Side View
Wall Mount AcCESSORIES
Front View
Rear View
Great Lakes Case & Cabinet Co., Inc.
Thank
You
WM, WD, WS and WE Series Wall Mount
Installation Instructions
for your
business!
MS-5.02-10 Rev.0
1-866-TRY-GLCC (879-4522)
Download PDF
Similar pages