Nuaire Catalogue - Residential Extract

Nuaire Residential EXTRACT 3_Layout 1 10/08/2011 11:41 Page 118
EXTR AC T
SL I MA I R E SI NG L E SP EED
TEC H NI C A L I NF O R MATI O N
SL I M A I RE 2 3 0 V & 1 2 V SI NGLE SPEED FANS
EXCEPTIONALLY QUIET, HIGH PERFORMANCE EXTRACT FANS FOR
WALL AND CEILING APPLICATIONS.
118
029 2085 8200
Nuaire Residential EXTRACT 3_Layout 1 10/08/2011 11:41 Page 119
EXTR AC T
SL I MA I R E SI NG L E SP EED
TEC H NI C A L I NF O R MATI O N
B E NE F I T S
MEETS REGULATIONS
EASY INSTALLATION
FIXED BACK DRAUGHT SHUTTERS
Part F Building regulations compliant.
Can be surfaced mounted or recessed.
Prevents draughts when fan not in operating mode.
ULTRA MODERN DESIGN
FLEXIBLE SOLUTIONS
1 YEAR WARRANTY
Provides an unobtrusive installation and occupant
acceptability.
Wide range of options to cover toilet, bathroom,
utility and kitchen applications.
For peace of mind.
IPX4 SPLASHPROOF
MAINTENANCE
Can safely be installed in Zones 1 and 2.
Clip of cover of access to clean.
QUIET RUNNING
FAN INDICATOR LIGHT
For occupant acceptability.
Showing the fans operation.
SLIMAIRE 100 & 150 SINGLE SPEED
MOUNTING OPTIONS
FANS
The Nuaire slimline range of axial fans
incorporates 12 models complete with
fixed back draft shutters. The fans have been
specifically designed to ventilate small rooms
such as toilets, bathrooms, shower rooms,
utility rooms and kitchens and are ideal for
wall, ceiling or panel installation. The units
extract directly to outside or through a short
length of ducting.
Wall mounting with outside grille.
Download specification from www.nuaire.co.uk/specifications
Ceiling mounting with outside roof cap.
nuaire.co.uk
119
Nuaire Residential EXTRACT 3_Layout 1 10/08/2011 11:41 Page 120
EXTR AC T
SL I MA I R E SI NG L E SP EED
TEC H NI C A L I NF O R MATI O N
PERFORMANCE SLIMLINE 100 & 150 SINGLE SPEED FANS
70
60
50
Fan Static Pressure (Pa)
Slimaire 150
40
30
Slimaire 100
20
10
0
0
10
20
30
40
50
60
70
80
90
Air volume flow rate (l/s)
SLIMLINE 100 & 150 - RANGE & CONTROL FUNCTION
Code
dBA@3m
Operating
voltage
Control function
SLIMAIRE 100/150
40/49
230
Standard version operated by remote switch.
SLIMAIRE 100PC/150PC
40/49
230
Standard version operated by pull cord.
SLIMAIRE 100T/150T
40/49
230
With integral overrun timer - the fan should be operated by a
remote switch which can also serve to switch the room light on
and off. After the light is switched off, the fan will continue to
operate for a minimum of 3 minutes (adjustable to a maximum
of 25 minutes) by turning the trimmer in a clockwise direction.
SLIMAIRE 100HT/150HT
40/49
230
With integral humidistat and overrun timer - the adjustable,
electronic humidistat is pre-set so that the fan will operate
automatically when the moisture content in the room reaches
a pre-set level of relative humidity. The fan will continue to run
until the relative humidity falls below the pre-set level.
This level can be adjusted by turning the trimmer on the fan.
This fan can be operated by a remote switch or light switch
allowing operation of the fan independently of the humidistat.
The overrun timer, which will always make the fan continue to
operate for the pre-set length of time even after it has been
manually switched off, can be adjusted as described above.
SLIMAIRE 100PIR/150PIR 40/49
230
With integral sensor and overrun timer - the fan will start to
operate automatically when it detects the presence of a person.
After the room is vacated, the fan will continue to operate
for a minimum of 3 minutes (adjustable to a maximum of
25 minutes) by turning the trimmer in an anti-clockwise
direction.
SLIMAIRE 100-12
40
12
This version must be installed using the remote transformer
supplied (see current IEE Regulations for guidance).
SLIMAIRE 100T-12
40
12
With integral overrun timer adjusted as above.
This version must be installed using the remote transformer
supplied (see current IEE Regulations for guidance).
120
029 2085 8200
Nuaire Residential EXTRACT 3_Layout 1 10/08/2011 11:41 Page 121
EXTR AC T
SL I MA I R E SI NG L E SP EED
TEC H NI C A L I NF O R MATI O N
DIMENSIONS (MM) - SLIMLINE 100 & 150 SINGLE SPEED FANS
B
D
DIMENSIONS (mm) & WEIGHTS
E
A
Unit
A
B
C
D
E dia.
Weight
(Kg)
SLIMAIRE 100
160
160
81
17
97
0.42
SLIMAIRE 150
200
200
119
22
149
1.04
C
WIRING - SLIMLINE 100 & 150 SINGLE SPEED FANS
SLIMAIRE 100/150 with remote switch.
L
L 230V
N
N
SLIMAIRE 100PC/150PC with pullcord.
~
50Hz
L
L 230V
N
N
SLIMAIRE 100T/150T
via light switch (or remote switch).
~
50Hz
N
N 230V
T
L
~
50Hz
L
Double Pole Isolator
Double Pole Isolator
Triple Pole Isolator
SLIMAIRE 100/150HT PIR with Humidistat
and Integral sensor.
SLIMAIRE 100-12, 12V
Must be installed with remote transformer.
SLIMAIRE 100T-12, 12V via light switch
(or remote switch).
Must be installed with remote transformer.
Transformer
L
L 230V
N
N
Transformer
~
50Hz
L N
L N
L N
L N
Double Pole Isolator
12V
230V
12V
L
N
N
L
230V
230V
~
50Hz
L
N
T
Fan unit
Download specification from www.nuaire.co.uk/specifications
Double Pole Isolator
Fan unit
Triple Pole Isolator
nuaire.co.uk
121
Nuaire Residential EXTRACT 3_Layout 1 10/08/2011 11:41 Page 125
EXTR AC T
SL I MA I R E
TEC H NI C A L I NF O R MATI O N
CO NSULTA NT S SP E CI FIC ATION
SLIMAIRE 100 & 150 SINGLE SPEED FANS
SLIMAIRE 100X & 150X TWIN SPEED FANS
Supplied by Nuaire Ltd the fan is to be suitable for installation either into a
ceiling, wall or panel (with the appropriate accessories) There should be a neon
on the front of the fan to indicate when it is operating. The fan casing should be
made of shockproof, high quality technopolymer, contain double insulated
motors of shaded poly type mounted on self-lubricating, sealed ball bearings for
long life, and be protected with a thermal cut-out.. The fan should be double
insulated and be suitable for installation into Zones I and II. The fan is to be CE
marked and comply with current EC Low Voltage Directive EMC89/336 and with
BSEN60529. The fan should finally comply with Building Regulations
requirements for installation into a utility room.
Supplied by Nuaire, this fan can either be for installation in a wall, panel, ceiling
or window (with optional kit). The fan should have three speeds, allowing a
choice of one of the two lower speeds for quiet, continuous operation at
installation. The user should be able to boost the fan to its maximum speed as
necessary. The fan should be made of shockproof high quality polymer and have
a maintenance free, self lubricating sleeve bearing motor for long life and
incorporates thermal cut-out.. The fan should be double insulated, splashproof
and CE marked. The fan should comply with Kitchen and Bathroom
requirements of System 3, Part F1 of the Building Regulations. It should be
capable of operation up to 9 l/sec, at 4 Pa, 2.6 watts at low speed 1, and at 12
l/sec, 14 Pa and 4.8 watts at low speed 2. Finally the fan should comply with EN
60335-2-80, EC Low Voltage Directive LVD 2006/95/CE and EC Directive
EMC2004/108 and be CE marked.
Download specification from www.nuaire.co.uk/specifications