iec 61000-4-4 / iec 61000-4-5 test report

Report No: 90706402-IM
IEC 61000-4-4 / IEC 61000-4-5
TEST REPORT
for
KWH METER
MODEL: DEM 510C; DEM 600; DEM 540
Test Report Number:
90706402-IM
Issued for
DAE Instrument Corp.
8th floor, No. 1 Singnan St., Nangang District, Taipei City 115,
Taiwan, R.O.C.
Issued By
Compliance Certification Services Inc.
Tainan Laboratory
No. 8, Jiu Cheng Ling, Jiaokeng Village, Sinhua
Township, Tainan Hsien 712, Taiwan R.O.C.
TEL: 886-6-580-2201
FAX: 886-6-580-2202
Issued Date: July 09, 2009
Note: This report shall not be reproduced except in full, without the written approval of Compliance
Certification Services Inc. This document may be altered or revised by Compliance Certification
Services Inc. personnel only, and shall be noted in the revision section of the document. The client
should not use it to claim product endorsement by TAF, NIST or any government agencies. The test
results in the report only apply to the tested sample.
Page 1 / 26
Report No: 90706402-IM
REVISION HISTORY
Rev.
Issue
Date
Revisions
Effect Page
Revised By
00
July 09, 2009
Initial Issue
ALL
Selena.Chong
Page 2
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
TABLE OF CONTENTS
1
TEST CERTIFICATION.................................................................................................... 4
2
TEST RESULT SUMMARY .............................................................................................. 5
3
EUT DESCRIPTION........................................................................................................... 6
4
TEST METHODOLOGY ................................................................................................... 7
4.1. DECISION OF FINAL TEST MODE................................................................................... 7
4.2. EUT SYSTEM OPERATION ............................................................................................... 7
5
SETUP OF EQUIPMENT UNDER TEST ........................................................................ 8
5.1. DESCRIPTION OF SUPPORT UNITS ................................................................................ 8
5.2. CONFIGURATION OF SYSTEM UNDER TEST............................................................... 9
6
FACILITIES AND ACCREDITATIONS ....................................................................... 10
6.1. FACILITIES ........................................................................................................................ 10
6.2. ACCREDITATIONS ........................................................................................................... 10
7
IMMUNITY TEST ............................................................................................................ 11
7.1. GENERAL DESCRIPTION ................................................................................................ 11
7.2. GENERAL PERFORMANCE CRITERIA DESCRIPTION .............................................. 12
7.3. ELECTRICAL FAST TRANSIENT (EFT) ........................................................................ 13
7.4. SURGE IMMUNITY TEST ................................................................................................ 18
8
PHOTOGRAPHS OF THE TEST CONFIGURATION ............................................... 24
Page 3
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
2
TEST RESULT SUMMARY
IMMUNITY【 EN 55024:1998 + A1: 2001 + A2: 2003 】
Standard
Item
Result
Remarks
Meets the requirements of Performance
IEC 61000-4-4:2004
EFT
PASS Criterion B
IEC 61000-4-5:2005
Surge
PASS Criterion B
Note:
Meets the requirements of Performance
1. The statements of test result on the above are decided by the request of test standard only; the
measurement uncertainties are not factored into this compliance determination.
2. The information of measurement uncertainty is available upon the customer’s request.
Page 5
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
3
EUT DESCRIPTION
Product
KWH METER
Model
DEM 510C; DEM 600; DEM 540
Applicant
DAE Instrument Corp.
Housing material
Plastics
Serial Number
DEM 510C
S/N: 51002425 DEM510C-2
DEM 600
S/N: 60001717 DEM600D-2
DEM 540
S/N: 10043552 DEM540C-2-0302
Received Date
July 06, 2009
Note: Client consigns only one model sample to test (Model Number: DEM 510C; DEM 600; DEM 540),
Therefore, the testing Lab. just guarantees the unit, which has been tested.
Page 6
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
4
TEST METHODOLOGY
4.1. DECISION OF FINAL TEST MODE
The EUT was tested together with the above additional components, and a configuration,
which produced the worst emission levels, was selected and recorded in this report.
The test configuration/ mode is as the following:
Test Mode:
1. Normal Operation
4.2. EUT SYSTEM OPERATION
1.
2.
3.
Setup a whole system for test as shown on setup diagram.
Turn on power and check function.
Start to test.
Page 7
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
5
SETUP OF EQUIPMENT UNDER TEST
5.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
No.
Product
Manufacturer
Model No.
Certify No.
Signal cable
1
LOAD
N/A
N/A
N/A
N/A
No. Signal cable description
A AC Input Cable
Unshielded 1.0m, 1pcs
B AC Output Cable
Unshielded 0.2 m, 1pcs
Note:
1) All the equipment/cables were placed in the worst-case configuration to maximize the emission during
the test.
2) Grounding was established in accordance with the manufacturer’s requirements and conditions for the
intended use.
Page 8
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
5.2. CONFIGURATION OF SYSTEM UNDER TEST
E.U.T
B
LOAD
A
AC Source
Page 9
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
6
FACILITIES AND ACCREDITATIONS
6.1. FACILITIES
All measurement facilities used to collect the measurement data are located at
No. 8, Jiu Cheng Ling, Jiaokeng Village,Sinhua Township, Tainan Hsien 712, Taiwan R.O.C.
The sites are constructed in conformance with the requirements of ANSI C63.4 and CISPR
Publication 22. All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference
Measuring Apparatus and Measurement Methods.”
6.2. ACCREDITATIONS
Our laboratories are accredited and approved by the following approval agencies according to
ISO/IEC 17025.
USA
FCC
Japan
VCCI
Canada
INDUSTRY CANADA
Taiwan
TAF, BSMI
Europe
TÜV NORD
Copies of granted accreditation certificates are available for downloading from our web site,
http://www.ccsemc.com.tw
Page 10
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7
IMMUNITY TEST
7.1. GENERAL DESCRIPTION
EN 55024:1998 + A1: 2001 + A2: 2003
Product Standard
Test Type
Minimum Requirement
IEC 61000-4-4
Electrical Fast Transient/Burst - EFT,
Power line: 1kV, Signal line: 0.5kV,
Performance Criterion B
IEC 61000-4-5
Surge Immunity Test:
1.2/50 us Open Circuit Voltage,
8 /20 us Short Circuit Current,
Power Port ~ Line to line: 1kV, Line to ground: 2kV
Signal Port ~ Lines to ground : 0.5kV
Performance Criterion B
Basic Standard,
Specification, and
Performance
Criterion
required
Page 11
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.2. GENERAL PERFORMANCE CRITERIA DESCRIPTION
Criteria A:
The apparatus shell continues to operate as intended without operator intervention. No
degradation of performance or loss of function is allowed below a performance level
specified by the manufacturer, when the apparatus is used as intended. The performance
level may be replaced by a permissible loss of performance. If the manufacturer does not
specify the minimum performance level or the permissible performance loss, then either
of these may be derived from the product description and documentation, and by what
the user may reasonably expect from the equipment if used as intended.
Criteria B:
After test, the apparatus shell continues to operate as intended without operator
intervention. No degradation of performance or loss of function is allowed, after the
application of the phenomenon below a performance level specified by the
manufacturer, when the apparatus is used as intended. The performance level may be
replaced by a permissible loss of performance.
During the test, degradation of performance is however allowed. However, no change of
operating state if stored data is allowed to persist after the test. If the manufacturer does
not specify the minimum performance level or the permissible performance loss, then
either of these may be derived from the product description and documentation, and by
what the user may reasonably expect from the equipment if used as intended.
Criteria C:
Temporary loss of function is allowed, provided the functions is self-recoverable or can
be restored by the operation of controls by the user in accordance with the manufacturer
instructions.
Functions, and/or information stored in non-volatile memory, or protected by a battery
backup, shall not be lost.
Page 12
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.3. ELECTRICAL FAST TRANSIENT (EFT)
7.3.1. TEST SPECIFICATION
IEC 61000-4-4
Basic Standard:
See 7.3.5 Test Results
Test Voltage:
Positive & Negative
Polarity:
5 kHz
Repetition Rate:
5/50 ns
Impulse Wave-shape:
15 ms
Burst Duration:
300 ms
Burst Period:
Not less than 1 min.
Test Duration:
7.3.2. TEST INSTRUMENT
Fast Transients/Burst Test Site (IEC/EN 61000-4-4)
Name of Equipment
Manufacturer
Model
Serial Number
Calibration Due
Computer
IBM
M/T 8183 - ICV
N.C.R.
VGA Monitor
Acer
1555
Keyboard
HP
KB - 0133
99BG137
9171602305842005
72P5C431
B69360MGAPEOK
5
EMC Pro IMMUNITY
TEST SYSTEM
KeyTek
EMCpro
0312231
DEC. 28, 2009
Test S/W
N.C.R.
N.C.R.
CE Ware 3.00b
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.
2. N.C.R.= No Calibration Required.
7.3.3. TEST PROCEDURE
a) Both positive and negative polarity discharges were applied.
b) The length of the “hot wire” from the coaxial output of the EFT generator to the terminals on
the EUT should not exceed 1 meter.
c) The duration time of each test sequential was 1 minute.
d) The transient/burst waveform was in accordance with EN 61000-4-4, 5/50ns.
Page 13
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.3.4. TEST SETUP
z
For the actual test configuration, please refer to the related item – Photographs of the Test
Configuration.
NOTE:
TABLETOP EQUIPMENT
The configuration consisted of a wooden table (0.8 m high) standing on the Ground Reference Plane. The
GRP consisted of a sheet of aluminum (at least 0.25 mm thick and 2.5 m square) connected to the
protective grounding system. A minimum distance of 0.5 m was provided between the EUT and the walls
of the laboratory or any other metallic structure.
FLOOR STANDING EQUIPMENT
The EUT installed in a representative system as described in section 7 of IEC 61000-4-4 and its cables,
were isolated from the Ground Reference Plane by an insulating support that is 0.1 meter thick. The GRP
consisted of a sheet of aluminum (at least 0.25 mm thick and 2.5 m square) connected to the protective
grounding system.
Page 14
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.3.5. TEST RESULTS
Model Number : DEM 510C
Temperature
25.3 oC
Humidity
62 % RH
Pressure
1026 mbar
Tested By
John Chen
Required Passing Performance
Criterion B
POWER
Performance
Criterion
Test Point
Polarity
Test Level
(kV)
L
+/-
4kV
A
B
C Note
1
2
3
A PASS
N
+/-
4kV
A
B
C Note
1
2
3
A PASS
L+ N
+/-
4kV
A
B
C Note
1
2
3
A PASS
Observation
Result
SIGNAL
Test Point
Performance
Criterion
Test Level
(kV)
Polarity
Observation
Result
N/A
Characteristics of the fast transient/burst generator
Burst
duration
+
15 ms_ 20%
Burst
Period
+
300 ms _ 20%
Repetition
Rate
Rise time
5 kHz
5 ns _ 30%
+
Duration
50 ns
+
_ 30%
NOTE:
1. Performance criteria A for immunity tests with phenomena of a continuous nature.
2. Performance criteria B for immunity test with phenomena of a transient nature.
3. Performance criteria C for immunity test with power interruptions, function loss and voltage
dips exceeding a certain period of time.
Page 15
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
Model Number : DEM 600
Temperature
25.3 oC
Humidity
62 % RH
Pressure
1026 mbar
Tested By
John Chen
Required Passing Performance
Criterion B
POWER
Performance
Criterion
Test Point
Polarity
Test Level
(kV)
L
+/-
4kV
A
B
C Note
1
2
3
A PASS
N
+/-
4kV
A
B
C Note
1
2
3
A PASS
L+ N
+/-
4kV
A
B
C Note
1
2
3
A PASS
Observation
Result
SIGNAL
Test Point
Performance
Criterion
Test Level
(kV)
Polarity
Observation
Result
N/A
Characteristics of the fast transient/burst generator
Burst
duration
+
15 ms_ 20%
Burst
Period
+
300 ms _ 20%
Repetition
Rate
Rise time
5 kHz
5 ns _ 30%
+
Duration
50 ns
+
_ 30%
NOTE:
1. Performance criteria A for immunity tests with phenomena of a continuous nature.
2. Performance criteria B for immunity test with phenomena of a transient nature.
3. Performance criteria C for immunity test with power interruptions, function loss and voltage
dips exceeding a certain period of time.
Page 16
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
Model Number : DEM 540
Temperature
25.3 oC
Humidity
62 % RH
Pressure
1026 mbar
Tested By
John Chen
Required Passing Performance
Criterion B
POWER
Performance
Criterion
Test Point
Polarity
Test Level
(kV)
L
+/-
4kV
A
B
C Note
1
2
3
A PASS
N
+/-
4kV
A
B
C Note
1
2
3
A PASS
L+ N
+/-
4kV
A
B
C Note
1
2
3
A PASS
Observation
Result
SIGNAL
Test Point
Performance
Criterion
Test Level
(kV)
Polarity
Observation
Result
N/A
Characteristics of the fast transient/burst generator
Burst
duration
+
15 ms_ 20%
Burst
Period
+
300 ms _ 20%
Repetition
Rate
Rise time
5 kHz
5 ns _ 30%
+
Duration
50 ns
+
_ 30%
NOTE:
1. Performance criteria A for immunity tests with phenomena of a continuous nature.
2. Performance criteria B for immunity test with phenomena of a transient nature.
3. Performance criteria C for immunity test with power interruptions, function loss and voltage
dips exceeding a certain period of time.
Page 17
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.4. SURGE IMMUNITY TEST
7.4.1. TEST SPECIFICATION
Basic Standard: IEC 61000-4-5
Wave-Shape: Combination Wave
1.2/50 us Open Circuit Voltage
8/20 us Short Circuit Current
Test Voltage: See 7.4.5 Test Results
Surge Input/Output: Power Line: L1-L2
Telecommunication line: T-Ground / R-Ground
Generator Source Impedance: 2 ohm between networks
12 ohm between network and ground
Polarity: Positive/Negative
Phase Angle: 0 / 90 / 180 / 270
Pulse Repetition Rate: 2 times / min. (maximum)
Number of Tests: 5 positive and 5 negative at selected points
7.4.2. TEST INSTRUMENT
Surge Immunity Test Site (IEC/EN EN 61000-4-5)
Name of Equipment
Manufacturer
Model
Serial Number
Calibration Due
Computer
IBM
M/T 8183 - ICV
N.C.R.
VGA Monitor
Acer
1555
Keyboard
EMC Pro IMMUNITY
TEST SYSTEM
HP
KB - 0133
99BG137
917160230584200572
P5C431
B69360MGAPEOK5
N.C.R.
KeyTek
EMCpro
0312231
DEC. 28, 2009
Test S/W
N.C.R.
CE Ware 3.00b
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
traceable to NML/ROC and NIST/USA.
2. N.C.R.= No Calibration Required.
Page 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.4.3. TEST PROCEDURE
a) For EUT power supply:
The surge is applied to the EUT power supply terminals via the capacitive coupling network.
Decoupling networks are required in order to avoid possible adverse effects on equipment not
under test that may be powered by the same lines, and to provide sufficient decoupling
impedance to the surge wave. The power cord between the EUT and the coupling/decoupling
networks was shorter than 2 meters in length.
b) For test applied to unshielded un-symmetrically operated interconnection lines of EUT:
The surge was applied to the lines via the capacitive coupling. The coupling / decoupling
networks didn’t influence the specified functional conditions of the EUT. The interconnection
line between the EUT and the coupling/decoupling networks was shorter than 2 meters in
length.
c) For test applied to unshielded symmetrically operated interconnection / telecommunication lines
of EUT:
The surge was applied to the lines via gas arrestors coupling. Test levels below the ignition
point of the coupling arrestor were not specified. The interconnection line between the EUT and
the coupling/decoupling networks was shorter than 2 meters in length.
Page 19
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.4.4. TEST SETUP
To AC
Source
Surge Immunity
Test
EUT
&
Support Units
0.8m
Controller Computer
z
For the actual test configuration, please refer to the related item – Photographs of the Test
Configuration.
Page 20
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
7.4.5. TEST RESULTS
Model Number: DEM 510C
Temperature
25.3 oC
Humidity
62 % RH
Pressure
1026 mbar
Tested By
John Chen
Required Passing Performance
Criterion B
Test Point
Polarity
Test Level
(kV)
L–N
+/-
6kV
Phase shifting
0°、90°、180°、270°
Repetition
Rate
30 sec
Performance
Criterion
A
B
Observation
C Note
Waveform
parameter
Combine Wave
1
2
Result
3
B Pass
Coupling Rate
1.2μs/50μs
8μs /20μs
5 times
Impedance
2Ω
Each Angle
and Polarity
NOTE:
1. Performance criteria A for immunity tests with phenomena of a continuous nature.
2. Performance criteria B for immunity test with phenomena of a transient nature.
3. Performance criteria C for immunity test with power interruptions, function loss and voltage
dips exceeding a certain period of time.
Page 21
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
Model Number: DEM 600
Temperature
25.3 oC
Humidity
62 % RH
Pressure
1026 mbar
Tested By
John Chen
Required Passing Performance
Criterion B
Test Point
Polarity
Test Level
(kV)
L–N
+/-
6kV
Phase shifting
Repetition
Rate
0°、90°、180°、270°
30 sec
Performance
Criterion
A
B
Observation
C Note
Waveform
parameter
Combine Wave
1
2
Result
3
B Pass
Coupling Rate
1.2μs/50μs
8μs /20μs
5 times
Impedance
2Ω
Each Angle
and Polarity
NOTE:
1. Performance criteria A for immunity tests with phenomena of a continuous nature.
2. Performance criteria B for immunity test with phenomena of a transient nature.
3. Performance criteria C for immunity test with power interruptions, function loss and voltage
dips exceeding a certain period of time.
Page 22
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
Model Number: DEM 540
Temperature
25.3 oC
Humidity
62 % RH
Pressure
1026 mbar
Tested By
John Chen
Required Passing Performance
Criterion B
Test Point
Polarity
Test Level
(kV)
L–N
+/-
6kV
Phase shifting
Repetition
Rate
0°、90°、180°、270°
30 sec
Performance
Criterion
A
B
Observation
C Note
Waveform
parameter
Combine Wave
1
2
Result
3
B Pass
Coupling Rate
1.2μs/50μs
8μs /20μs
5 times
Impedance
2Ω
Each Angle
and Polarity
NOTE:
1. Performance criteria A for immunity tests with phenomena of a continuous nature.
2. Performance criteria B for immunity test with phenomena of a transient nature.
3. Performance criteria C for immunity test with power interruptions, function loss and voltage
dips exceeding a certain period of time.
Page 23
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
8
PHOTOGRAPHS OF THE TEST CONFIGURATION
EFT TEST
Model Number : DEM 510C
Model Number : DEM 600
Page 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
Model Number : DEM 540
SURGE TEST
Model Number : DEM 510C
Page 25
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Report No: 90706402-IM
Model Number : DEM 600
Model Number : DEM 540
END OF REPORT
Page 26
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
Download PDF