Product Data - Carrier Enterprise

215B
Legacyt Line Heat Pump
with Puronr Refrigerant
Size 1--1/2 - 5 Nominal Tons
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 14.0 -- 16.0 SEER/ 11.0--13.0 EER / 8.2 -- 9.0 HSPF
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 69 dBA
S Sound levels as low as 68 dBA with accessory sound blanket
Comfort
S System supports Edger Thermidistatt or standard thermostat
controls
Reliability
the environmentally sound refrigerant
S
S
S
S
S
S
S
S
Non--ozone depleteing Puronr refrigerant
Scroll compressor
Internal pressure relief valve
Internal thermal overload
High pressure switch
Loss of charge switch
Filter drier
Balanced refrigeration system for maximum reliability
Durability
Bryant heat pumps with Puronr refrigerant provide a collection of
features unmatched by any other family of equipment. The 215B
has been designed utilizing Bryant’s non--ozone depleting Puron
refrigerant.
This product has been designed and manufactured to meet Energy
Starr criteria for energy efficiency when matched with appropriate
coil components. Refer to the AHRI directory for system
combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.
DuraGuard Plust protection package:
S Solid, durable sheet metal construction
S Dense wire coil guard standard
S Baked--on powder paint
Applications
S Long--line -- up to 250 feet (76.20 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)
S Low ambient cooling (down to --10_F/--23_C) with accessory
kit
MODEL NUMBER NOMENCLATURE
1
N
2
N
3
N
4
A
5
A/N
6
N
7
N
8
N
9
N
10
A/N
11
A/N
12
N
14
A
2
1
5
B
N
A
0
3
6
0
0
0
0
Product
Family
2=HP
Tier
SEER
Voltage
Open
Open
Open
1=
Legacy
RNC
5=15 SEER
Major
Series
B=Puron
0=Not
Defined
0=Not
Defined
0=Not
Defined
Minor
Series
A=
Original
Series
Grille
Variations
N= 208 ---230 ---1 A = Standard
or 208/230 ---1
Cooling Capacity
the environmentally sound refrigerant
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
This product has been designed and manufactured to
meet Energy Star criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
STANDARD FEATURES
Feature
18
24
30
36
37
42
48
60
Puron Refrigerant
X
X
X
X
X
X
X
X
15.0
16.0
15.5
15.5
16.0
16.0
15.5
15.0
X
X
X
X
X
X
X
X
Maximum SEER Rating*
Scroll Compressor
Crankcase Heater
X
X
Field Installed Filter Drier
X
X
X
X
X
X
X
X
Front Seating Service Valves
X
X
X
X
X
X
X
X
Internal Pressure Relief Valve
X
X
X
X
X
X
X
X
Internal Thermal Overload
X
X
X
X
X
X
X
X
Long Line capability
X
X
X
X
X
X
X
X
Low Ambient cooling capability with Kit
X
X
X
X
X
X
X
X
Suction Line Accumulator
X
X
X
X
X
X
X
X
High Pressure Switch
X
X
X
X
X
X
X
X
Loss of Charge Switch
X
X
X
X
X
X
X
X
Dense Grille
X
X
X
X
X
X
X
X
X = Standard
* = Based on AHRI rated system combinations
2
PHYSICAL DATA
UNIT SIZE SERIES
Compressor Type
REFRIGERANT
Control
18--- A
Charge lb (kg)
5.6 (2.54)
Outdoor Heating Piston #
42
COND FAN
Air Discharge
Air Qty (CFM)
Motor HP
Motor RPM
COND COIL
Face Area (Sq ft)
Fins per In.
Rows
Circuits
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIGERANT TUBES (In. OD)
Rated Vapor*
Liquid
24--- A
30--- A
36--- A
7.60
(3.45)
46
7.00
(3.18)
52
37--- A
Scroll
Puron (R---410A)
TXV (Puron Hard Shutoff)
7.40
11.20 (5.08)
(3.34)
61
55
Propeller Type, Direct Drive
Vertical
3810
3223
1/5
1/12
800
810
2233
1/12
800
3223
1/12
800
3223
1/12
800
15.09
20
1
4
20.12
20
1
5
20.12
20
1
5
22.63
20
1
6
5/8
5/8
3/4
3/4
42--- A
48--- A
60--- A
8.90
(4.04)
61
9.60
(4.35)
67
3810
1/5
800
4046
1/4
800
4046
1/4
800
20.10
20
2
8
17.60
20
2
7
17.60
20
2
7
25.15
20
2
9
3/4
7/8
7/8
7/8
3/4
7/8
7/8
1 1/8
12.50 (5.67)
76
3/8”
5/8
5/8
3/4
3/4
3/8
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for HP systems with Puron refrigerant:
Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications
Unit
Nominal
Size (Btuh)
18,000
1--- Stage
HP with
Puron
24,000
1--- Stage
HP with
Puron
30,000
1--- Stage
HP with
Puron
36,000
37,000
1--- Stage
HP with
Puron
42,000
1--- Stage
HP with
Puron
48,000
1--- Stage
HP with
Puron
60,000+
1--- Stage
HP with
Puron
Maximum
Liquid Line
Diameters
(In. OD)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line
Diameters
(In.) OD
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Standard
Application
26--- 50
51--- 80
Long Line Application Requires Accessories
81--- 100
101--- 125
126--- 150
151--- 175
176--- 200
201--- 225
226--- 250
(7.9--- 15.2)
(15.5--- 24.4)
(24.7--- 30.5)
(30.8--- 38.1)
(38.4--- 45.7)
(46.0--- 50.3)
(53.6--- 60.0)
(61.3--- 68.6)
(68.9--- 76.2)
1/2
1
2
3
4
6
7
8
9
10
5/8
0
0
1
1
1
2
2
3
3
5/8
0
1
1
2
3
3
4
4
5
3/4
0
0
0
0
1
1
1
1
1
5/8
1
2
3
3
4
5
6
7
8
3/4
0
0
1
1
1
2
2
2
3
7/8
0
0
0
0
1
1
1
1
1
5/8
1
2
4
5
6
7
9
10
11
3/4
0
0
1
1
2
2
3
3
4
7/8
0
0
0
0
1
1
1
1
2
3/4
0
1
2
2
3
4
4
5
6
7/8
0
0
1
1
1
2
2
2
3
3/4
0
1
2
3
4
5
5
6
7
7/8
0
0
1
1
2
2
2
3
3
3/4
1
2
4
5
6
7
9
10
11
7/8
0
1
2
2
3
4
4
5
5
1 ---1/8
0
0
0
1
1
1
1
1
1
Standard Length = 80 ft. (24.4 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
3
REFRIGERANT PIPING LENGTH LIMITATIONS
Maximum Line Lengths:
The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for
allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit.
Maximum Line Lengths for Heat Pump Applications
MAXIMUM ACTUAL LENGTH
ft (m)
MAXIMUM EQUIVALENT LENGTH{
ft (m)
MAXIMUM VERTICAL
SEPARATION ft (m)
Units on equal level
200 (61)
250 (76.2)
N/A
Outdoor unit ABOVE
indoor unit
200 (61)
250 (76.2)
200 (61)
Outdoor unit BELOW
indoor unit
See Table ’Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit’
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
Maximum Total Equivalent Length{ -- Outdoor Unit BELOW Indoor Unit
Size
Liquid Line
Diameter
w/ TXV
18000
HP with
Puron
24000
HP with
Puron
30000
HP with
Puron
36000
37000
HP with
Puron
42000
HP with
Puron
48000
HP with
Puron
60000
HP with
Puron
0--- 20
(0 --- 6.1)
HP with Puronr Refrigerant --- Maximum Total Equivalent Length{
Vertical Separation ft (m) Outdoor unit BELOW indoor unit;
21--- 30
31--- 40
41--- 50
51--- 60
61--- 70
(6.4 --- 9.1)
(9.4 --- 12.2)
(12.5 --- 15.2)
(15.5 --- 18.3)
(18.6 --- 21.3)
71--- 80
(21.6 --- 24.4)
3/8
250*
250*
250*
250*
250*
250*
250*
3/8
250*
250*
250*
250*
250*
250*
250*
3/8
250*
250*
250*
250*
250*
250*
250*
3/8
250*
250*
250*
250*
250*
250*
250*
3/8
250*
250*
250*
250*
250*
250*
150
3/8
250*
250*
250*
250*
230
160
--- ---
3/8
250*
225*
190
150
110
--- ---
--- ---
* Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
--- --- = outside acceptable range
LONG LINE APPLICATIONS
An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable
refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing,
and vertical separation between the indoor and outdoor units.
For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories
are required:
HP WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m)
Beyond these lengths, long line accessories are required
Liquid Line Size
Units On Same Level
Outdoor Below Indoor
Outdoor Above Indoor
3/8
80 (24.4)
20 (6.1) vertical or 80 (24.4) total
80 (24.4)
Note: See Long Line Guideline for details
4
ACCESSORIES
ACCESSORY
NO.
DESCRIPTION
HC32GE229
HC38GE228
HC40GE228
KAACH1201AAA
KAACH1401AAA
KAACH1601AAA
KAACH1701AAA
KAACS0201PTC
MOTOR,FAN
MOTOR,FAN
MOTOR,FAN
CRANKCASE HEATER KIT
CRANKCASE HEATER KIT
CRANKCASE HEATER KIT
CRANKCASE HEATER KIT
KIT PTC
HIGH PRESSURE SWITCH
KIT
LOW PRESSURE SWITCH
KIT
SOLENOID VALVE KIT
TIME DELAY KIT
WINTER START KIT
ISOLATION RELAY KIT
SOLENOID VALVE KIT
OUTDR THERM KIT
OUTDR THERM KIT
SNOW STAND KIT
CYCLE PROTECTOR KIT
FREEZE THERM KIT
HARD START KIT
HARD START KIT
LOW AMBIENT KIT
MOTORMASTER KIT
SUPPORT FEET KIT
SOUND BLKT KIT
SOUND BLKT KIT
SOUND BLKT KIT
SOUND BLKT KIT
TXV KIT, COPPER
TXV KIT, COPPER
TXV KIT, COPPER
TXV KIT, COPPER
TXV KIT, ALUMINIUM
TXV KIT, ALUMINIUM
TXV KIT, ALUMINIUM
KAAHI0501PUR
KAALP0401PUR
18--- A
X
24--- A
X
30--- A
X
UNIT SIZE
36--- A
37--- A
X
42--- A
48--- A
60--- A
X
X
X
X
X
X
X
X
X
X
X
X
KAALS0201LLS
KAATD0101TDR
X
KAAWS0101AAA
KHAIR0201AAA
X
KHALS0401LLS
X
KHAOT0201SEC
X
KHAOT0301FST
X
KHASS0606MPK*
X
KSACY0101AAA
X
KSAFT0101AAA
X
KSAHS1701AAA
X
KSAHS1501AAA
KSALA0301410
X
KSALA0601AAA
X
KSASF0201AAA
X
KSASH0601COP
X
KSASH0601COP
X
KSASH2101COP
KSASH2301COP
KSATX0201PUR
X
KSATX0301PUR
KSATX0401PUR
KSATX0501PUR
KSBTX0201PUR
X
KSBTX0301PUR
KSBTX0401PUR
x = Accessory
* Order through RCD ---Totaline, part number KHASS0606MPK (qty 6).
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
ACCESSORY THERMOSTATS
Part Number
Capabilities
Description
Heat
Stages
Cool
Stages
√
√
√
√
√
4
3
3
3
3
2
2
2
2
2
√
√
√
√
3
3
3
2
2
2
2
1
Gas
Electric
Heat
Pump
√
√
√
√
√
√
√
√
√
T6 ---WEM01
T6 ---PRH01 ---A
T6 ---PHP01
T6 ---NRH01 ---A
T6 ---NHP01
Housewise™ Wi---Fi Programmable Relative Humidity Thermostat
Programmable Relative Humidity Thermostat
Programmable Thermostat (HP or AC)
Non ---Programmable Relative Humidity Thermostat
Non ---Programmable Thermostat (HP or AC)
√
√
T2 ---WHS01
T2 ---PHP01
T2 ---NHP01
T2SNHP01
Wi---Fi® Programmable
5 ---2 Day Programmable Thermostat
Non ---Programmale Thermostat (HP or AC)
Non ---Programmable Thermostat (HP or AC)
√
√
Thermostat Accessories
Part Number
Description
Used With
T6 ---EXP01 ---A
ExP Computer Programming Accessory
T6 ---P thermostats
TSTATXXCNV10
Thermostat Conversion Kit (4 to 5 wire) --- 10 pack
TX ---LBP01
Large Decorative Backplate
TX ---MBP01
Medium Decorative Backplate
TSTATXXSEN01 ---B
Outdoor Air Temperature Sensor
All Bryant branded thermostats
T6 ---Pxx, T6 ---Nxx, and T2 ---Pxx
T2 ---Nxx
All T6 --- thermostats
5
ACCESSORY USAGE GUIDELINE
REQUIRED FOR LOW --- AMBIENT
COOLING APPLICATIONS
(Below 55F / 12.8C)
Standard
Yes{
REQUIRED FOR
LONG LINE APPLICATIONS*
(Over 80 ft. / 24.38 m)
Standard
No
REQUIRED FOR
SEA COAST APPLICATIONS
(Within 2 miles / 3.22 km)
Standard
No
Yes
Yes
No
Crankcase Heater
Yes
Yes
No
Evaporator Freeze Thermostat
Hard Shutoff TXV
Isolation Relay
Liquid Line Solenoid Valve
Motor Master Control or
Low Ambient Switch
Support Feet
Yes
Yes
Yes
No
No
Yes
No
See Long---Line Application Guideline
No
Yes
No
No
Yes
No
No
Recommended
No
Recommended
Accessory
Accumulator
Ball Bearing Fan Motor
Compressor Start Assist Capacitor and
Relay
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline
Application Guideline.
{ Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control.
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when using MotorMasterr
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor
at each start up.
Usage Guideline:
Required for reciprocating compressors in the following
applications:
Long line
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the
compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles. Improves
compressor lubrication on restart and minimizes the chance of
liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
5. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation
when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.
6. Isolation Relay
An SPDT relay which switches the low--ambient controller out of
the outdoor fan motor circuit when the heat pump switches to
heating mode.
Usage Guideline:
Required in all heat pumps where low ambient kit has
been added.
7. Liquid--Line Solenoid Valve (LLS)
An electrically operated shutoff valve which stops and starts
refrigerant liquid flow in response to compressor operation. It is to
be installed at the outdoor unit to control refrigerant off cycle
migration in the heating mode.
Usage Guideline:
An LLS is required in all long line heat pump
applications to control refrigerant off cycle migration in
the heating mode. See Long Line Guideline.
8. Low--Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in order
to maintain head pressure within normal operating limits. The
control will maintain working head pressure at low--ambient
temperatures down to --10_F (--23_C) when properly installed.
Usage Guideline:
A Low--Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling
operation is used at outdoor temperatures below 55_F
(12.8_C).
9. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --10_F (--23_C), it
maintains condensing temperature at 100_F 10_F (37.8_C 
6.5_C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or
Low--Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55_F (12.8_C).
Suggested for all commercial applications.
6
Accessory Description and Usage (Listed Alphabetically) -- CONTINUED
10. Outdoor Air Temperature Sensor
Designed for use with Bryant Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also is required to enable special
thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Bryant thermostats listed in this
publication.
11. Outdoor Thermostat
An SPDT temperature--actuated switch which turns on
supplemental electric heaters when outdoor air temperature drops
below a user--selected set point.
Usage Guideline:
Electric supplemental heat applications in non--variable
speed indoor units when electric heat staging is desired.
12. Secondary Outdoor Thermostat
An SPDT temperature--actuated switch which turns on third--stage
of supplemental electric heaters when outdoor air temperature
drops below the second--stage set point.
Usage Guideline:
Outdoor thermostat applications where electric heater is
capable of 3--stage operation.
13. Snow Stand
Coated wire rack which supports unit 18 in. (457.2 mm) above
mounting pad to allow for drainage from unit base.
Usage Guideline:
Suggested in the following applications:
Heat pump installations in heavy snowfall areas.
Heat pump installations in snow drift locations.
Heat pump installations in areas of prolonged
subfreezing temperatures.
All commercial installations.
Note: Snow stand does not support 26” X 26” (660 X 660 mm)
small basepan size.
14. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the
sound level by about 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft.
(4.577 m) to quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses less
than 10 ft. (3.05 m) apart.
15. Thermostatic Expansion Valve (TXV) Bi--Flow
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Usage Guideline:
Accessory required to meet AHRI rating and system
reliability, where indoor not equipped.
Required in all heat pump applications designed with
Puron refrigerant.
16. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
Note: Most indoor unit controls include this feature. For those that
do not, use the guideline below.
Usage Guideline:
Accessory required to meet AHRI rating, where indoor
not equipped.
7
ELECTRICAL DATA
UNIT SIZE
V/PH
18--- A
24--- A
30--- A
36--- A
37--- A
42--- A
48--- A
60--- A
208/230/1
OPER VOLTS*
MAX
MIN
253
197
COMPR
LRA
48.0
58.3
73.0
79.0
75.0
109.0
117.0
134.0
FAN
FLA
0.5
0.5
0.5
1.2
0.6
1.2
1.2
1.2
RLA
9.0
12.8
14.1
16.7
16.8
21.1
21.8
26.4
MCA
MAX FUSE** or
BRK AMPS
11.8
16.5
18.1
22.1
21.6
27.6
28.5
34.2
20
25
30
35
35
40
40
50
*
{
Permissible limits of the voltage range at which the unit will operate satisfactorily
If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70). The ampacity of non ---metallic---sheathed cable (NM),
trade name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or 75_C
insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA
70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1
A--WEIGHTED SOUND POWER (dBA)
UNIT SIZE
18--- A
24--- A
30--- A
36--- A
37--- A
42--- A
48--- A
60--- A
STANDARD
RATING
dBA
73
69
71
72
72
74
74
74
TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)
125
250
500
1000
2000
4000
8000
49.5
48.5
51.0
55.5
67.7
56.5
55.5
59.0
60.0
59.5
58.5
59.5
66.8
64.0
62.0
62.0
65.0
61.5
61.5
63.5
68.1
67.0
66.0
65.0
69.0
62.5
65.5
66.5
69.9
68.5
69.0
68.0
65.5
61.0
62.5
64.5
62.8
65.0
65.0
65.0
62.0
59.0
60.0
61.5
60.3
62.0
62.0
62.5
55.0
53.5
53.5
55.5
55.2
57.5
56.0
62.0
NOTE: 37 size tested in accordance with AHRI Standard 270 ---2008 (not listed in AHRI). All other sizes tested in accordance with AHRI Standard 270 ---1995
(not listed in AHRI).
A--WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD
UNIT SIZE
18--- A
24--- A
30--- A
36--- A
37--- A
42--- A
48--- A
60--- A
STANDARD
RATING
dBA
72
68
69
70
71
72
72
73
TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)
125
250
500
1000
2000
4000
8000
50.5
49.5
50.5
54.5
68.2
56.5
55.5
58.5
60.0
58.5
58.5
57.5
66.4
64.5
62.5
62.5
65.0
61.5
61.5
63.0
67.5
66.5
66.0
65.0
67.5
62.0
64.0
66.0
68.4
66.5
68.0
67.0
64.5
61.0
61.5
64.0
59.6
64.5
64.0
64.0
61.5
58.5
58.5
61.0
58.2
61.0
60.0
61.0
53.5
51.5
51.5
54.0
52.4
54.5
53.0
56.5
NOTE: 37 size tested in accordance with AHRI Standard 270 ---2008 (not listed in AHRI). All other sizes tested in accordance with AHRI Standard 270 ---1995
(not listed in AHRI).
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- SERIES
18--- A
24--- A
30--- A
36--- A
37--- A
42--- A
48--- A
60--- A
REQUIRED SUBCOOLING ° F (° C)
12 (6.7)
13 (7.2)
10 (5.6)
10 (5.6)
10 (5.6)
12 (6.7)
13 (7.2)
13 (7.2)
8
9
A
A
A
A
A
A
A
A
215BNA018000GAAA
215BNA024000GAAA
215BNA030000GAAA
215BNA036000GAAA
215BNA037000BAAA
215BNA042000GAAA
215BNA048000GAAA
215BNA060000GAAA
18
24,30,36,37,42,48,60
UNIT SIZE
SERIES
UNIT
A
Y=YES
N=NO
INCH
N 31 3/16
N
35
N
35
N
35
N
35
N
35
N
35
N
35
23 1/8
25 3/4
31 3/16
35
"X"
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y
Y
208-230-1-60
587.3
654.0
792.5
889.0
MINIMUM GROUND MOUNTING
PAD APPLICATION DIMENSIONS
N
N
N
N
N
N
N
N
460-3-60
208/230-3-60
ELECTRICAL
CHARACTERISTICS
DIMENSIONS
575-3-60
17
20
22
26
7/8
7/16
15/16
3/4
"Y"
INCH
28 11/16
32 1/16
32 1/16
35 1/2
32 1/16
28 11/16
28 11/16
38 7/8
MM
728.7
815.1
815.1
901.4
815.1
728.7
728.7
987.8
INCH
5/8
5/8
3/4
3/4
3/4
7/8
7/8
7/8
454.6
518.5
583.2
679.7
MINIMUM ROOF-TOP MOUNTING
PAD APPLICATION DIMENSIONS
MM
792.5
889.0
889.0
889.0
889.0
889.0
889.0
889.0
B
C
MM
15.9
15.9
19.1
19.1
19.1
22.2
22.2
22.2
INCH
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
D
INCH
24 11/16
28 7/16
28 7/16
28 7/16
28 7/16
28 7/16
28 7/16
28 7/16
MM
626.3
722.8
722.8
722.8
722.8
722.8
722.8
722.8
INCH
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
F
MM
231.3
231.3
231.3
231.3
231.3
231.3
231.3
231.3
INCH
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
G
MM
28.2
28.2
28.2
28.2
28.2
28.2
28.2
28.2
INCH
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
H
MM
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
NOTE: ALL DIMENSIONS IN INCH (MM)
MM
166.1
166.1
166.1
166.1
166.1
166.1
166.1
166.1
E
INCH
16
3/4
1/4
3/4
3/8
17
16 3/4
17 1/4
15
16
15
17
I
MM
381.0
425.5
406.4
425.5
444.5
425.5
412.8
412.8
INCH
14
16 1/2
15 1/2
17
13 3/4
14 3/4
14
18 1/4
MM
355.6
419.1
393.7
431.8
349.3
374.7
355.6
463.6
1. CENTER OF GRAVITY
NOTES:
INCH
15
16 3/4
16
16 3/4
17 1/2
16 3/4
16 1/4
16 1/4
K
Lbs
169
200
196
215
215
245
260
294
.
Kgs
76.7
90.7
88.9
97.5
97.5
111.1
117.9
133.4
OPERATING
WEIGHT
Lbs
207
233
242
257
253
290
303
345
Kgs
93.9
105.7
109.8
116.6
114.8
131.5
137.4
156.5
SHIPPING
WEIGHT
U.S. ECCN: Not Subject to Regulation (N.S.R.)
MM
406.4
400.1
412.8
400.1
441.3
431.8
425.5
438.2
J
INCH
MM
33 3/16 843.1
36 5/8
929.5
36 5/8
929.5
40
1015.8
36 5/8
929.5
33 3/16 843.1
33 3/16 843.1
43 3/8 1102.2
SHIPPING
HEIGHT
SD5386-4 REV. B
SHIPPING
LENGTH / WIDTH
(Sq.)
INCH
MM
33 5/16 846.6
37 1/8
943.1
37 1/8
943.1
37 1/8
943.1
37 1/8
943.1
37 1/8
943.1
37 1/8
943.1
37 1/8
943.1
10
BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY,
MBTUH
-8
20
-3
30
2
40
7
17
018 Size
024 Size
030 Size
037 Size
036 Size
042 Size
048 Size
060 Size
22
0
OUTDOOR TEMPERATURE, ºF
50
60
70
BASED ON INDOOR RATED
COMBINATION WITH ENT. AIR AT 70 ºF
AND AT RATED CFM
12
80
8.8
11.7
14.6
17.6
20.5
23.4
0.0
2.9
10
-13
10
0
-18
5.9
-10
-23
20
30
40
50
60
70
80
OUTDOOR TEMPERATURE, 0C
BALANCE POINT WORKSHEET
215B BALANCE POINT WORKSHEET
kW
11
24”
(609.6)
Service
12”
(304.8)
Note: Numbers in ( ) = mm
18”
(457.2)
24”
(609.6)
Service
Wall
6”
(152.4)
18”
(457.2)
12”
(304.8)
24”
(609.6)
Service
Wall
18”
(457.2)
12”
(304.8)
Clearances (various examples)
24”
(609.6)
Service
12”
(304.8)
24”
(609.6)
Service
Wall
6”
(152.4)
IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air.
CLEARANCES
Wall
TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Bryant database at: www.MyBryantRatings.com
For performance data at specific application &/or design conditions with various indoor unit combinations, the
equipment performance calculator can be accessed at : http://rpmobbry.wrightsoft.com/
Model
Number
Coil Model Number
215BNA018---A
215BNA024---A
215BNA030---A
215BNA036---A
215BNA037---A
215BNA042---A
215BNA048---A
215BNA060---A
FX4DNF019L
FX4DNF025L
FX4DN(B,F)031L
FX4DN(B,F)037L
FX4DN(B,F)049L
FX4DN(B,F)043L
FX4DN(B,F)049L
FX4DN(B,F)061L
Furnace
Model Number
Cooling
Capacity
EER
SEER
17,800
24,000
28,400
34,800
35,000
41,500
47,500
57,000
12.5
12.5
12.5
12.0
13.0
12.5
12.5
12.5
15.0
15.0
15.0
15.0
16.0
15.0
15.0
15.0
High Temp
E
E COP
Capacity
17,800
3.92
24,000
3.96
28,200
3.98
34,600
3.92
35,000
4.16
42,000
3.82
45,500
3.84
56,000
3.86
HSPF
8.5
8.5
8.5
8.5
8.5
8.5
8.5
8.5
Low Temp
H
H COP
Capacity
10,700
2.60
14,700
2.68
17,000
2.66
21,400
2.64
20,800
2.86
26,400
2.62
29,000
2.66
35,400
2.72
* AHRI = Air Conditioning, Heating & Refrigeration Institute
Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit.
High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43° F (6_C) wb air entering outdoor unit.
Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (---8_C) db 15° F (---9_C) wb air entering outdoor unit.
COP — Coefficient of Performance
EER — Energy Efficiency Ratio
HSPF — Heating Seasonal Performance Factor
SEER — Seasonal Energy Efficiency Ratio
12
13
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
EWB
° F (° C)
See note on pg. 16
900
800
700
CFM
EVAPORATOR AIR
675
600
525
CFM
EWB
° F (° C)
EVAPORATOR AIR
75 (23.9)
11.10
13.52
13.00
15.88
16.80
11.69
14.44
13.86
17.11
17.61
12.24
15.33
14.69
18.24
18.29
Sens‡
28.25
25.63
23.76
23.28
22.30
28.87
26.21
24.31
23.85
23.30
29.34
26.65
24.73
24.35
24.14
Total
14.67
17.92
17.24
21.08
22.30
15.41
19.09
18.34
22.64
23.30
16.11
20.21
19.38
24.04
24.14
Sens‡
Capacity MBtuh
21.38
19.37
17.92
17.54
16.80
21.87
19.84
18.37
18.01
17.61
22.26
20.21
18.73
18.42
18.29
Total
Capacity MBtuh
75 (23.9)
1.50
1.48
1.46
1.46
1.46
1.53
1.50
1.48
1.48
1.48
1.56
1.52
1.50
1.50
1.50
Total
System
KW**
1.10
1.10
1.10
1.10
1.10
1.11
1.11
1.11
1.11
1.11
1.12
1.12
1.12
1.12
1.12
Total
System
KW**
85 (29.4)
85 (29.4)
10.70
13.12
12.60
15.47
16.15
11.28
14.03
13.45
16.68
16.90
11.82
14.90
14.27
17.56
17.54
Sens‡
27.04
24.52
22.71
22.25
21.50
27.60
25.04
23.21
22.80
22.45
28.03
25.44
23.59
23.29
23.24
Total
14.21
17.44
16.76
20.58
21.50
14.93
18.60
17.84
22.10
22.45
15.63
19.71
18.88
23.29
23.24
Sens‡
Capacity MBtuh
20.34
18.43
17.05
16.69
16.15
20.79
18.85
17.45
17.13
16.90
21.13
19.17
17.76
17.56
17.54
Total
Capacity MBtuh
DETAILED COOLING CAPACITIES#
1.60
1.59
1.59
1.59
1.59
1.61
1.60
1.60
1.60
1.60
1.62
1.61
1.61
1.61
1.61
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
215BNA024--- A Outdoor Section With FX4DNF025 Indoor Section
1.70
25.76
13.71
1.91
24.38
13.19
2.15
1.67
23.33
16.94
1.88
22.05
16.40
2.12
1.66
21.59
16.25
1.87
20.38
15.71
2.10
1.65
21.17
20.06
1.87
20.00
19.48
2.10
1.65
20.65
20.65
1.86
19.72
19.72
2.10
1.73
26.26
14.44
1.94
24.83
13.91
2.17
1.69
23.80
18.09
1.90
22.47
17.55
2.14
1.68
22.04
17.33
1.89
20.78
16.77
2.12
1.68
21.69
21.51
1.89
20.58
20.58
2.12
1.67
21.53
21.53
1.89
20.55
20.55
2.12
1.75
26.65
15.12
1.96
25.17
14.59
2.20
1.72
24.16
19.19
1.93
22.79
18.63
2.16
1.70
22.39
18.35
1.91
21.09
17.78
2.14
1.70
22.31
22.31
1.91
21.27
21.27
2.15
1.70
22.28
22.28
1.91
21.24
21.24
2.15
215BNA018--- A Outdoor Section With FX4DNF019 Indoor Section
1.25
19.25
10.28
1.42
18.10
9.85
1.25
17.43
12.70
1.41
16.38
12.26
1.25
16.12
12.18
1.41
15.14
11.74
1.25
15.79
15.04
1.41
14.85
14.58
1.25
15.45
15.45
1.41
14.70
14.70
1.26
19.64
10.85
1.43
18.44
10.41
1.26
17.80
13.60
1.42
16.70
13.15
1.26
16.48
13.02
1.42
15.45
12.57
1.26
16.21
16.12
1.42
15.36
15.36
1.26
16.15
16.15
1.42
15.34
15.34
1.27
19.94
11.39
1.44
18.70
10.94
1.27
18.08
14.47
1.43
16.95
14.01
1.27
16.76
13.83
1.43
15.70
13.37
1.27
16.76
16.76
1.43
15.90
15.90
1.27
16.74
16.74
1.43
15.88
15.88
Total
System
KW**
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
115 (46.1)
115 (46.1)
9.40
11.81
11.28
13.91
13.89
9.95
12.69
12.10
14.49
14.47
10.48
13.53
12.89
14.98
14.96
Sens‡
22.88
20.66
19.07
18.77
18.70
23.27
21.02
19.42
19.49
19.46
23.56
21.30
19.69
20.12
20.10
Total
12.63
15.83
15.13
18.68
18.70
13.34
16.96
16.18
19.49
19.46
14.01
18.03
17.17
20.12
20.10
Sens‡
Capacity MBtuh
16.88
15.26
14.10
13.91
13.89
17.17
15.54
14.37
14.49
14.47
17.39
15.75
14.58
14.98
14.96
Total
Capacity MBtuh
2.41
2.38
2.37
2.37
2.37
2.44
2.40
2.39
2.39
2.39
2.46
2.43
2.41
2.41
2.41
Total
System
KW**
1.80
1.79
1.79
1.78
1.78
1.81
1.80
1.80
1.80
1.80
1.82
1.81
1.81
1.81
1.81
Total
System
KW**
125 (51.7)
125 (51.7)
8.93
11.33
10.80
13.03
13.01
9.47
12.20
11.61
13.56
13.54
10.00
13.03
12.38
14.00
13.98
Sens‡
21.23
19.12
17.61
17.59
17.56
21.57
19.44
17.92
18.28
18.26
21.82
19.68
18.16
18.86
18.84
Total
12.03
15.20
14.49
17.59
17.56
12.73
16.32
15.53
18.28
18.26
13.39
17.38
16.50
18.86
18.84
Sens‡
Capacity MBtuh
15.59
14.08
12.99
13.03
13.01
15.83
14.31
13.22
13.56
13.54
16.02
14.49
13.40
14.00
13.98
Total
Capacity MBtuh
2.71
2.68
2.68
2.68
2.68
2.73
2.71
2.70
2.70
2.70
2.76
2.73
2.71
2.72
2.72
Total
System
KW**
2.03
2.02
2.01
2.01
2.01
2.04
2.03
2.02
2.02
2.02
2.05
2.04
2.03
2.04
2.04
Total
System
KW**
14
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
EWB
° F (° C)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
See note on pg. 16
1350
1200
1050
CFM
EWB
° F (° C)
EVAPORATOR AIR
1125
1000
875
CFM
EVAPORATOR AIR
75 (23.9)
17.74
21.80
20.97
25.74
27.40
18.63
23.23
22.30
27.61
28.58
19.48
24.59
23.56
29.51
29.56
Sens‡
41.59
37.90
35.22
34.53
33.22
42.40
38.68
35.97
35.34
34.65
43.03
39.27
36.55
36.05
35.84
Total
22.07
27.12
26.13
32.04
33.22
23.16
28.89
27.78
34.38
34.65
24.20
30.57
29.35
36.44
35.84
Sens‡
Capacity MBtuh
34.40
31.23
28.95
28.38
27.40
35.08
31.88
29.57
29.06
28.58
35.61
32.37
30.05
29.68
29.56
Total
Capacity MBtuh
75 (23.9)
2.25
2.23
2.22
2.21
2.21
2.28
2.26
2.25
2.24
2.24
2.31
2.29
2.28
2.28
2.28
Total
System
KW**
1.83
1.82
1.81
1.81
1.81
1.86
1.85
1.84
1.84
1.84
1.89
1.87
1.86
1.86
1.86
Total
System
KW**
85 (29.4)
17.14
21.20
20.37
25.12
26.39
18.02
22.61
21.68
26.92
27.49
18.86
23.96
22.94
28.45
28.41
Sens‡
39.75
36.20
33.62
32.97
32.01
40.49
36.90
34.30
33.74
33.35
41.06
37.43
34.82
34.51
34.46
Total
21.35
26.38
25.39
31.27
32.01
22.43
28.13
27.02
33.54
33.35
23.46
29.81
28.58
34.51
34.46
Sens‡
Capacity MBtuh
32.81
29.80
27.62
27.09
26.39
33.43
30.37
28.18
27.73
27.49
33.89
30.81
28.60
28.45
28.41
Total
Capacity MBtuh
85 (29.4)
215BNA036--- A Outdoor Section With FX4DNF037 Indoor Section
2.51
37.77
20.58
2.79
35.67
19.78
2.48
34.37
25.60
2.77
32.42
24.78
2.47
31.90
24.60
2.75
30.07
23.77
2.47
31.31
30.44
2.75
29.55
29.53
2.46
30.68
30.68
2.74
29.25
29.25
2.54
38.44
21.66
2.83
36.24
20.84
2.52
35.00
27.34
2.80
32.97
26.50
2.50
32.52
26.22
2.78
30.61
25.37
2.50
32.07
31.86
2.78
30.45
30.45
2.50
31.93
31.93
2.78
30.41
30.41
2.58
38.93
22.68
2.86
36.68
21.85
2.55
35.47
29.00
2.83
33.38
28.14
2.53
32.98
27.76
2.81
31.02
26.89
2.53
33.01
33.01
2.81
31.41
31.41
2.53
32.97
32.97
2.81
31.37
31.37
Total
System
KW**
3.11
3.09
3.07
3.07
3.06
3.15
3.12
3.10
3.10
3.10
3.18
3.15
3.13
3.14
3.14
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
215BNA030--- A Outdoor Section With FX4DNF031 Indoor Section
2.05
31.16
16.52
2.29
29.42
15.88
2.56
2.04
28.29
20.57
2.28
26.69
19.93
2.55
2.03
26.22
19.74
2.27
24.73
19.09
2.54
2.03
25.75
24.46
2.26
24.33
23.73
2.54
2.02
25.32
25.32
2.26
24.15
24.15
2.54
2.08
31.71
17.39
2.32
29.89
16.74
2.59
2.06
28.80
21.98
2.30
27.13
21.31
2.58
2.05
26.71
21.05
2.29
25.16
20.38
2.57
2.05
26.39
26.39
2.29
25.13
25.13
2.57
2.05
26.34
26.34
2.29
25.10
25.10
2.57
2.11
32.11
18.22
2.35
30.24
17.56
2.62
2.09
29.18
23.31
2.33
27.47
22.63
2.60
2.08
27.09
22.29
2.32
25.49
21.60
2.59
2.08
27.22
27.22
2.32
25.91
25.91
2.60
2.08
27.19
27.19
2.32
25.88
25.88
2.59
DETAILED COOLING CAPACITIES# CONTINUED
115 (46.1)
115 (46.1)
15.20
19.24
18.39
22.91
22.88
16.05
20.60
19.66
23.77
23.74
16.86
21.90
20.86
24.49
24.46
Sens‡
33.40
30.32
28.09
27.74
27.70
33.91
30.79
28.56
28.80
28.76
34.27
31.16
28.92
29.67
29.63
Total
18.93
23.91
22.88
27.74
27.70
19.98
25.60
24.46
28.80
28.76
20.98
27.22
25.95
29.67
29.63
Sens‡
Capacity MBtuh
27.55
24.96
23.11
22.91
22.88
27.95
25.35
23.49
23.77
23.74
28.25
25.64
23.78
24.49
24.46
Total
Capacity MBtuh
3.48
3.45
3.44
3.44
3.44
3.51
3.49
3.47
3.47
3.47
3.55
3.52
3.50
3.51
3.51
Total
System
KW**
2.87
2.86
2.86
2.86
2.86
2.90
2.89
2.88
2.88
2.88
2.93
2.91
2.91
2.91
2.91
Total
System
KW**
125 (51.7)
125 (51.7)
14.48
18.49
17.64
21.51
21.48
15.32
19.84
18.88
22.28
22.26
16.12
21.10
20.05
22.92
22.89
Sens‡
30.96
28.05
25.96
26.04
26.00
31.38
28.46
26.36
26.99
26.96
31.68
28.76
26.67
27.77
27.74
Total
18.02
22.97
21.93
26.04
26.00
19.05
24.65
23.49
26.99
26.96
20.04
26.23
24.94
27.77
27.74
Sens‡
Capacity MBtuh
25.53
23.10
21.35
21.51
21.48
25.86
23.43
21.67
22.28
22.26
26.10
23.68
21.93
22.92
22.89
Total
Capacity MBtuh
3.90
3.88
3.87
3.87
3.86
3.93
3.91
3.90
3.90
3.90
3.96
3.94
3.93
3.93
3.93
Total
System
KW**
3.23
3.22
3.22
3.22
3.22
3.25
3.24
3.24
3.24
3.24
3.28
3.27
3.27
3.27
3.27
Total
System
KW**
15
36.17
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
See note on pg. 16
1575
1400
1225
CFM
EWB
° F (° C)
75 (23.9)
36.17
36.11
29.96
31.41
25.15
34.81
34.99
28.25
29.58
23.99
33.22
32.48
26.47
27.66
22.75
50.43
45.65
42.23
41.36
39.50
51.53
46.66
43.19
42.36
41.23
52.37
47.45
43.93
43.23
42.69
Total
25.70
31.32
30.12
36.82
39.50
26.95
33.31
31.97
39.45
41.23
28.11
35.19
33.72
41.84
42.69
Sens‡
Capacity MBtuh
36.31
62 (16.7)
39.88
67 (19.4)
36.68
44.45
72 (22.2)
63 (17.2††
34.81
57 (13.9)
39.14
67 (19.4)
35.41
43.63
72 (22.2)
62 (16.7)
33.22
57 (13.9)
36.00
34.44
62 (16.7)
63 (17.2††
35.13
38.21
67 (19.4)
63 (17.2††
42.58
2.47
2.59
2.67
2.68
2.72
2.47
2.60
2.69
2.70
2.72
2.48
2.62
2.71
2.72
2.73
Total
System
KW**
2.16
2.17
2.17
2.20
2.25
2.12
2.13
2.13
2.16
2.21
2.08
2.09
2.10
2.13
2.17
75 (23.9)
Capacity MBtuh†
Total System KW**
Total
Sens‡
72 (22.2)
EWB
° F (° C)
EVAPORATOR AIR
1350
1200
1050
CFM
EVAPORATOR AIR
85 (29.4)
34.61
34.67
29.07
30.52
24.25
33.36
34.03
27.40
28.70
23.10
31.88
31.63
25.64
26.81
21.89
48.01
43.47
40.23
39.42
38.01
48.98
44.38
41.08
40.35
39.62
49.72
45.05
41.73
41.18
40.98
Total
24.76
30.39
29.20
35.88
38.01
25.98
32.35
31.02
38.44
39.62
27.13
34.20
32.75
40.82
40.98
Sens‡
Capacity MBtuh
34.61
34.67
34.71
37.73
42.03
33.36
33.64
34.11
37.08
41.32
31.88
32.73
33.34
36.25
40.39
33.04
33.09
28.19
29.61
23.34
31.88
31.94
26.54
27.83
22.21
30.52
30.75
24.81
25.96
21.02
2.70
2.70
2.70
2.73
2.78
2.66
2.66
2.66
2.69
2.74
2.62
2.62
2.63
2.66
2.70
31.38
31.42
30.72
33.34
37.06
30.33
30.38
30.25
32.84
36.54
29.08
29.26
29.66
32.22
35.86
31.38
31.42
27.28
28.69
22.41
30.33
30.38
25.66
26.93
21.29
29.08
29.80
23.95
25.09
20.13
3.00
3.00
2.99
3.02
3.07
2.96
2.96
2.96
2.99
3.03
2.92
2.92
2.92
2.95
215BNA042--- A Outdoor Section With FX4DNF043 Indoor Section
2.86
45.51
23.81
3.26
42.89
22.83
2.96
41.22
29.44
3.33
38.86
28.47
3.01
38.16
28.26
3.36
35.97
27.30
3.02
37.42
34.91
3.37
35.33
33.87
3.04
36.44
36.44
3.38
34.77
34.77
2.88
46.35
25.01
3.29
43.62
24.01
2.98
42.00
31.37
3.36
39.54
30.39
3.04
38.90
30.06
3.40
36.62
29.07
3.05
38.28
37.36
3.40
36.20
36.20
3.06
37.93
37.93
3.41
36.14
36.14
2.90
47.00
26.14
3.31
44.15
25.12
3.00
42.59
33.23
3.39
40.05
32.20
3.07
39.46
31.77
3.43
37.10
30.75
3.07
39.23
39.23
3.43
37.32
37.32
3.08
39.18
39.18
3.44
37.28
37.28
3.69
3.73
3.74
3.75
3.75
3.72
3.76
3.78
3.78
3.78
3.75
3.80
3.82
3.82
3.82
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
33.04
33.09
32.75
35.56
39.59
31.88
31.94
32.21
35.00
38.97
30.52
31.00
31.53
34.27
38.17
2.99
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Capacity MBtuh†
Capacity MBtuh†
Total SysTotal System KW**
tem KW**
Total
Sens‡
Total
Sens‡
215BNA037---A Outdoor Section With FX4DN(B,F)049L Indoor Section
Total
System
KW**
2.43
2.43
2.43
2.46
2.51
2.39
2.39
2.39
2.42
2.47
2.35
2.35
2.36
2.39
2.43
85 (29.4)
Capacity MBtuh†
Total System KW**
Total
Sens‡
DETAILED COOLING CAPACITIES# CONTINUED
115 (46.1)
29.59
29.63
26.32
27.71
21.44
28.66
28.69
24.73
25.99
20.35
27.53
27.57
23.06
24.18
19.21
40.16
36.38
33.68
33.17
32.98
40.76
36.95
34.22
34.27
34.22
41.21
37.37
34.64
35.29
35.25
Total
21.82
27.46
26.29
32.70
32.98
22.98
29.35
28.03
34.27
34.22
24.07
31.13
29.68
35.29
35.25
Sens‡
Capacity MBtuh
29.59
29.63
28.58
30.98
34.41
28.66
28.69
28.18
30.58
33.99
27.53
27.57
27.68
30.04
33.42
4.13
4.15
4.16
4.16
4.16
4.17
4.19
4.20
4.20
4.20
4.20
4.23
4.24
4.24
4.24
Total
System
KW**
3.34
3.34
3.33
3.36
3.41
3.30
3.30
3.30
3.33
3.37
3.26
3.27
3.27
3.29
3.33
115 (46.1)
Capacity MBtuh†
Total System KW**
Total
Sens‡
125 (51.7)
27.64
27.67
25.28
26.67
20.43
26.81
26.84
23.74
22.44
19.35
25.81
25.85
22.14
23.21
18.24
37.25
33.74
31.23
31.09
31.05
37.75
34.21
31.69
32.20
32.16
38.11
34.58
32.04
33.12
33.08
Total
20.76
26.40
25.22
31.09
31.05
21.90
28.25
26.94
32.20
32.16
22.98
30.00
28.54
33.12
33.08
Sens‡
Capacity MBtuh
27.64
27.67
26.31
28.50
31.59
26.81
26.84
25.96
29.01
31.26
25.81
25.85
25.63
27.71
30.80
4.61
4.62
4.61
4.61
4.61
4.65
4.66
4.66
4.66
4.66
4.69
4.70
4.70
4.70
4.70
Total
System
KW**
3.75
3.75
3.74
3.76
3.80
3.71
3.71
3.70
3.73
3.77
3.67
3.67
3.67
3.69
3.73
125 (51.7)
Capacity MBtuh†
Total System KW**
Total
Sens‡
16
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
EWB
° F (° C)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
75 (23.9)
29.54
36.19
34.83
42.67
45.11
30.99
38.52
37.01
45.78
47.07
32.35
40.74
39.08
48.58
48.72
Sens‡
69.17
63.19
58.86
57.71
55.78
70.36
64.35
59.99
58.97
58.06
71.26
65.22
60.84
60.05
59.92
Total
35.96
44.51
42.93
52.83
55.78
37.71
47.38
45.61
56.64
58.06
39.37
50.14
48.17
60.05
59.92
Sens‡
Capacity MBtuh
57.01
51.80
48.03
47.07
45.11
58.19
52.92
49.09
48.18
47.07
59.07
53.74
49.89
49.14
48.72
Total
Capacity MBtuh
75 (23.9)
3.81
3.74
3.69
3.68
3.66
3.89
3.82
3.77
3.76
3.75
3.97
3.89
3.84
3.84
3.84
Total
System
KW**
2.89
2.93
2.94
2.95
2.96
2.93
2.97
2.99
2.99
2.99
2.97
3.01
3.03
3.03
3.03
Total
System
KW**
85 (29.4)
28.44
35.09
33.75
41.56
43.35
29.86
37.39
35.89
44.58
45.16
31.20
39.59
37.94
46.76
46.68
Sens‡
65.83
60.19
56.08
55.03
53.67
66.90
61.20
57.09
56.19
55.76
67.65
61.95
57.83
57.56
57.48
Total
34.68
43.24
41.67
51.53
53.67
36.42
46.09
44.32
55.19
55.76
38.06
48.81
46.84
57.56
57.48
Sens‡
Capacity MBtuh
54.18
49.25
45.68
44.77
43.35
55.20
50.21
46.60
45.81
45.16
55.98
50.94
47.31
46.76
46.68
Total
Capacity MBtuh
85 (29.4)
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
215BNA060--- A Outdoor Section With FX4DNF061 Indoor Section
4.20
62.32
33.37
4.63
58.60
31.99
5.12
4.13
57.00
41.92
4.56
53.63
40.55
5.05
4.08
53.14
40.35
4.51
50.02
38.98
5.00
4.07
52.20
50.14
4.50
49.23
48.59
4.99
4.05
51.40
51.40
4.49
48.93
48.93
4.99
4.28
63.21
35.07
4.71
59.35
33.67
5.20
4.21
57.88
44.75
4.64
54.36
43.33
5.13
4.15
54.01
42.98
4.59
50.76
41.57
5.08
4.15
53.39
53.39
4.58
50.73
50.73
5.08
4.14
53.31
53.31
4.58
50.67
50.67
5.08
4.36
63.86
36.70
4.79
59.89
35.28
5.27
4.28
58.50
47.43
4.71
54.89
45.99
5.20
4.23
54.65
45.48
4.66
51.31
44.03
5.15
4.23
54.95
54.95
4.67
52.14
52.14
5.16
4.23
54.88
54.88
4.67
52.08
52.08
5.16
CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
215BNA048--- A Outdoor Section With FX4DNF049 Indoor Section
3.33
51.32
27.34
3.75
48.40
26.24
4.19
3.33
46.66
33.99
3.74
44.00
32.89
4.16
3.33
43.28
32.66
3.73
40.82
31.56
4.14
3.33
42.47
40.43
3.72
40.10
39.24
4.13
3.33
41.52
41.52
3.72
39.62
39.62
4.13
3.37
52.22
28.73
3.80
49.16
27.61
4.24
3.38
47.50
36.26
3.79
44.73
35.13
4.22
3.38
44.10
34.77
3.78
41.52
33.65
4.19
3.38
43.44
43.29
3.78
41.21
41.21
4.19
3.38
43.19
43.19
3.77
41.16
41.16
4.19
3.42
52.88
30.05
3.85
49.73
28.92
4.30
3.43
48.12
38.45
3.84
45.26
37.27
4.27
3.43
44.71
36.78
3.83
42.06
35.63
4.25
3.43
44.65
44.65
3.83
42.49
42.49
4.25
3.43
44.59
44.59
3.83
42.43
42.43
4.25
115 (46.1)
115 (46.1)
25.11
31.75
30.42
37.67
37.60
26.47
33.97
32.48
39.05
39.00
27.76
36.08
34.43
40.19
40.15
Sens‡
54.63
50.02
46.68
46.32
46.26
55.24
50.63
47.31
47.86
47.80
55.65
51.06
47.75
49.11
49.05
Total
30.54
39.09
37.53
46.32
46.26
32.20
41.84
40.08
47.86
47.80
33.79
44.45
42.48
49.11
49.05
Sens‡
Capacity MBtuh
45.36
41.24
38.24
37.67
37.60
46.01
41.84
38.85
39.05
39.00
46.49
42.30
39.30
40.19
40.15
Total
Capacity MBtuh
5.68
5.61
5.56
5.56
5.56
5.75
5.69
5.64
5.65
5.65
5.82
5.76
5.71
5.73
5.73
Total
System
KW**
4.66
4.62
4.60
4.59
4.59
4.71
4.68
4.65
4.65
4.65
4.77
4.73
4.71
4.71
4.71
Total
System
KW**
125 (51.7)
125 (51.7)
23.93
30.55
29.21
35.46
35.41
25.27
32.75
31.24
36.72
36.67
26.55
34.81
33.14
37.73
37.69
Sens‡
50.41
46.18
43.12
43.40
43.34
50.87
46.66
43.61
44.74
44.69
51.19
47.00
43.99
45.81
45.76
Total
29.02
37.54
35.99
43.40
43.34
30.66
40.25
38.48
44.74
44.69
32.24
42.79
40.82
45.81
45.76
Sens‡
Capacity MBtuh
42.16
38.29
35.50
35.46
35.41
42.69
38.81
36.02
36.72
36.67
43.06
39.19
36.40
37.73
37.69
Total
Capacity MBtuh
6.30
6.25
6.21
6.21
6.21
6.38
6.32
6.28
6.30
6.29
6.45
6.39
6.35
6.38
6.38
Total
System
KW**
5.18
5.14
5.12
5.12
5.12
5.23
5.20
5.17
5.18
5.18
5.29
5.25
5.22
5.24
5.24
Total
System
KW**
* Tested combination.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
} Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240 ---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity
may occur.
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
EWB — Entering Wet Bulb
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
2250
2000
1750
CFM
EWB
° F (° C)
EVAPORATOR AIR
1800
1600
1400
CFM
EVAPORATOR AIR
DETAILED COOLING CAPACITIES# CONTINUED
17
5.22
5.30
4.84
4.92
4.99
4.50
4.59
4.66
675
525
600
675
525
600
675
8.38
8.52
8.64
7.98
8.12
8.24
7.57
7.71
7.82
800
900
700
800
900
700
800
900
Total
700
CFM
---3 ( ---19.4)
4.29
4.22
4.14
4.59
4.53
4.45
4.87
4.80
4.72
Integ*
7.19
7.09
6.97
7.58
7.47
7.35
7.95
7.83
7.71
Integ*
Capacity MBtuh
5.13
Total
600
See note on pg. 19
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
---3 ( ---19.4)
Capacity MBtuh
525
CFM
INDOOR AIR
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
INDOOR AIR
1.50
1.50
1.49
1.43
1.43
1.42
1.37
1.36
1.36
Total
Syst.
KW†
1.12
1.12
1.11
1.07
1.07
1.07
1.02
1.02
1.02
Total
Syst.
KW†
7 ( ---13.9)
6.36
6.27
6.16
6.66
6.57
6.47
6.94
6.85
6.75
Integ*
10.60
10.46
10.29
11.00
10.86
10.69
11.39
11.24
11.07
Total
9.74
9.61
9.46
10.11
9.98
9.83
10.47
10.33
10.18
Integ*
Capacity MBtuh
6.92
6.82
6.70
7.25
7.15
7.04
7.55
7.46
7.34
Total
Capacity MBtuh
7 ( ---13.9)
1.58
1.58
1.59
1.51
1.51
1.51
1.44
1.44
1.44
Total
Syst.
KW†
1.17
1.17
1.17
1.12
1.12
1.12
1.07
1.07
1.07
Total
Syst.
KW†
HEAT PUMP HEATING PERFORMANCE
17 ( ---8.3)
8.54
8.42
8.29
8.85
8.74
8.60
9.15
9.03
8.90
13.66
13.44
13.23
14.30
14.15
13.97
14.59
14.45
14.28
Total
12.45
12.26
12.06
13.04
12.90
12.74
13.30
13.17
13.02
Integ*
Capacity MBtuh
9.36
9.24
9.09
9.71
9.58
9.43
10.04
9.91
9.76
Total
27 ( ---2.8)
37 (2.8)
10.91
10.79
10.64
11.16
11.04
10.90
11.37
11.27
11.13
1.27
1.29
1.30
1.21
1.23
1.24
1.16
1.17
1.18
14.91
14.75
14.56
15.21
15.05
14.86
15.51
15.35
15.15
13.57
13.43
13.25
13.84
13.70
13.52
14.12
13.97
13.78
1.64
1.65
1.66
1.57
1.58
1.59
1.49
1.50
1.52
1.33
1.34
1.37
1.26
1.28
1.31
1.20
1.22
1.24
Total
Integ*
Capacity MBtuh
27 ( ---2.8)
Total
Syst.
KW†
Total
Integ*
Capacity MBtuh
37 (2.8)
16.91
16.74
16.55
17.21
17.04
16.84
17.50
17.34
17.14
15.02
14.87
14.70
15.28
15.13
14.96
15.54
15.40
15.23
1.70
1.71
1.73
1.61
1.63
1.65
1.53
1.54
1.57
20.15
19.94
19.70
20.50
20.30
20.05
20.85
20.64
20.39
18.33
18.15
17.93
18.66
18.47
18.24
18.98
18.79
18.56
1.75
1.77
1.80
1.66
1.68
1.71
1.58
1.60
1.63
Total
Syst.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
12.29
12.15
11.98
12.56
12.44
12.28
12.80
12.68
12.54
215BNA024---A Outdoor Section With FX4DNF025 Indoor Section
Total
Syst.
KW†
1.22
1.22
1.23
1.16
1.17
1.18
1.11
1.11
1.12
Total
Syst.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
Total
Total
Capacity MBtuh
Capacity MBtuh
Syst.
Syst.
Integ*
Total
Integ*
Total
Integ*
KW†
KW†
215BNA018---A Outdoor Section With FX4DNF019 Indoor Section
Capacity MBtuh
17 ( ---8.3)
47 (8.3)
47 (8.3)
17.86
17.65
17.39
18.21
18.00
17.74
18.56
18.35
18.08
Integ*
23.85
23.59
23.28
24.26
24.00
23.68
24.67
24.41
24.08
Total
23.85
23.59
23.28
24.26
24.00
23.68
24.67
24.41
24.08
Integ*
Capacity MBtuh
17.86
17.65
17.39
18.21
18.00
17.74
18.56
18.35
18.08
Total
Capacity MBtuh
1.83
1.86
1.90
1.74
1.77
1.81
1.66
1.68
1.72
Total
Syst.
KW†
1.39
1.42
1.45
1.33
1.35
1.38
1.27
1.29
1.32
Total
Syst.
KW†
57 (13.9)
57 (13.9)
20.95
20.82
20.50
21.20
21.15
20.89
21.37
21.43
21.28
Integ*
28.05
27.76
27.36
28.53
28.21
27.81
28.96
28.68
28.29
Total
28.05
27.76
27.36
28.53
28.21
27.81
28.96
28.68
28.29
Integ*
Capacity MBtuh
20.95
20.82
20.50
21.20
21.15
20.89
21.37
21.43
21.28
Total
Capacity MBtuh
1.96
1.99
2.04
1.87
1.90
1.95
1.77
1.81
1.86
Total
Syst.
KW†
1.46
1.50
1.55
1.39
1.42
1.48
1.31
1.35
1.41
Total
Syst.
KW†
67 (19.4)
67 (19.4)
23.53
23.58
23.52
23.75
23.87
23.84
23.93
24.11
24.15
Integ*
32.25
32.27
31.99
32.53
32.56
32.46
32.79
32.90
32.83
Total
32.25
32.27
31.99
32.53
32.56
32.46
32.79
32.90
32.83
Integ*
Capacity MBtuh
23.53
23.58
23.52
23.75
23.87
23.84
23.93
24.11
24.15
Total
Capacity MBtuh
2.08
2.15
2.24
1.98
2.04
2.13
1.88
1.94
2.02
Total
Syst.
KW†
1.52
1.57
1.63
1.45
1.49
1.55
1.37
1.42
1.48
Total
Syst.
KW†
18
9.94
10.10
9.22
9.40
9.56
8.65
8.83
8.98
1125
875
1000
1125
875
1000
1125
11.66
11.86
10.73
10.95
11.15
9.98
10.20
10.39
1200
1350
1050
1200
1350
1050
1200
1350
12.02
12.24
12.42
11.39
11.59
11.78
10.74
10.95
11.12
1200
1350
1050
1200
1350
1050
1200
1350
Total
1050
CFM
See note on pg. 19
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
---3 ( ---19.4)
---3 ( ---19.4)
9.55
9.38
9.19
10.26
10.08
9.87
10.91
10.73
10.52
Integ*
10.23
10.08
9.88
10.84
10.67
10.48
11.43
11.26
11.06
Integ*
Capacity MBtuh
11.44
Total
1050
CFM
8.26
8.12
7.96
8.80
8.65
8.49
9.29
9.15
8.98
Integ*
Capacity MBtuh
9.76
Total
875
INDOOR AIR
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
---3 ( ---19.4)
Capacity MBtuh
1000
CFM
INDOOR AIR
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
INDOOR AIR
2.06
2.04
2.03
1.97
1.96
1.95
1.88
1.87
1.86
Total
Sys.
KW†
2.19
2.18
2.17
2.09
2.08
2.07
2.00
1.98
1.97
Total
Syst.
KW†
1.76
1.75
1.74
1.69
1.67
1.66
1.61
1.60
1.59
Total
Syst.
KW†
7 ( ---13.9)
11.47
11.30
11.11
11.97
11.80
11.61
12.44
12.27
12.08
Integ*
7 ( ---13.9)
13.25
13.03
12.79
13.92
13.70
13.45
14.55
14.34
14.09
Integ*
15.56
15.35
15.11
16.15
15.94
15.69
16.74
16.51
16.26
Total
14.30
14.11
13.89
14.84
14.64
14.42
15.38
15.17
14.95
Integ*
Capacity MBtuh
14.41
14.18
13.92
15.15
14.91
14.64
15.83
15.60
15.33
Total
Capacity MBtuh
12.48
12.30
12.09
13.03
12.84
12.63
13.53
13.35
13.14
Total
Capacity MBtuh
7 ( ---13.9)
2.18
2.17
2.17
2.08
2.08
2.08
1.99
1.98
1.99
Total
Sys.
KW†
2.27
2.26
2.26
2.17
2.16
2.16
2.07
2.06
2.06
Total
Syst.
KW†
1.83
1.82
1.82
1.75
1.74
1.74
1.67
1.66
1.66
Total
Syst.
KW†
20.57
19.83
19.47
21.01
20.80
20.56
21.41
21.20
20.98
Total
Total
Syst.
KW†
1.90
1.90
1.90
1.81
1.81
1.82
1.73
1.73
1.73
18.48
18.29
18.05
18.81
18.64
18.43
19.13
18.94
18.75
1.99
2.00
2.01
1.89
1.90
1.92
1.80
1.81
1.83
24.80
24.56
24.28
25.20
24.96
24.68
25.61
25.37
25.07
22.56
22.35
22.09
22.93
22.71
22.46
23.31
23.08
22.82
2.35
2.35
2.36
2.25
2.25
2.25
2.15
2.15
2.15
2.06
2.08
2.11
1.97
1.98
2.01
1.87
1.89
1.91
Total
Integ*
Capacity MBtuh
27 ( ---2.8)
Total
Syst.
KW†
Total
Integ*
Capacity MBtuh
37 (2.8)
21.05
20.76
20.40
21.70
21.41
21.05
22.90
22.07
21.68
2.45
2.45
2.47
2.34
2.35
2.36
2.25
2.24
2.26
29.66
29.35
28.97
30.17
29.87
29.52
30.66
30.35
29.99
26.99
26.71
26.36
27.46
27.19
26.86
27.90
27.62
27.29
2.57
2.59
2.63
2.45
2.47
2.51
2.34
2.36
2.39
27 ( ---2.8)
37 (2.8)
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
23.70
23.37
22.97
24.44
24.10
23.71
25.78
24.85
24.41
Total
Syst.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
20.81
20.59
20.33
21.18
20.99
20.75
21.54
21.33
21.11
Total
Syst.
KW†
18.75
18.08
17.75
19.15
18.96
18.74
19.52
19.33
19.12
2.29
2.28
2.28
2.19
2.19
2.20
2.08
2.09
2.10
24.73
24.51
24.28
25.14
24.92
24.66
25.57
25.34
25.06
21.97
21.77
21.56
22.33
22.13
21.91
22.71
22.51
22.25
2.37
2.38
2.40
2.26
2.27
2.29
2.15
2.16
2.18
29.36
29.09
28.76
29.85
29.56
29.23
30.35
30.05
29.70
26.72
26.47
26.17
27.16
26.90
26.60
27.62
27.35
27.03
2.45
2.46
2.50
2.33
2.35
2.38
2.22
2.24
2.27
Total
Total
Total
Capacity MBtuh
Capacity MBtuh
Sys.
Sys.
Sys.
Integ*
Total
Integ*
Total
Integ*
KW†
KW†
KW†
215BNA037-A Outdoor Section With FX4DN(B,F)049L Indoor Section
17 ( ---8.3)
17.16
16.92
16.62
17.81
17.56
17.26
18.42
18.17
17.88
Integ*
Capacity MBtuh
18.82
18.55
18.23
19.53
19.26
18.94
20.21
19.93
19.61
Total
37 (2.8)
215BNA036---A Outdoor Section With FX4DNF037 Indoor Section
17 ( ---8.3)
14.80
14.60
14.37
15.29
15.09
14.86
15.75
15.56
15.32
Capacity MBtuh
16.23
16.02
15.76
16.77
16.55
16.30
17.28
17.06
16.80
Total
27 ( ---2.8)
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
Total
Total
Capacity MBtuh
Capacity MBtuh
Syst.
Syst.
Integ*
Total
Integ*
Total
Integ*
KW†
KW†
215BNA030---A Outdoor Section With FX4DNF031 Indoor Section
Capacity MBtuh
17 ( ---8.3)
HEAT PUMP HEATING PERFORMANCE CONTINUED
47 (8.3)
47 (8.3)
29.22
28.93
28.57
29.70
29.40
29.04
30.18
29.87
29.50
Integ*
47 (8.3)
34.80
34.43
34.00
35.37
35.00
34.56
35.94
35.57
35.11
Integ*
34.77
34.42
33.99
35.36
35.00
34.55
35.96
35.66
35.13
Total
34.77
34.42
33.99
35.36
35.00
34.55
35.96
35.66
35.13
Integ*
Capacity MBtuh
34.80
34.43
34.00
35.37
35.00
34.56
35.94
35.57
35.11
Total
Capacity MBtuh
29.22
28.93
28.57
29.70
29.40
29.04
30.18
29.87
29.50
Total
Capacity MBtuh
2.55
2.58
2.62
2.44
2.47
2.51
2.33
2.36
2.40
Total
Sys.
KW†
2.68
2.71
2.76
2.56
2.59
2.63
2.44
2.47
2.52
Total
Syst.
KW†
2.16
2.18
2.22
2.06
2.08
2.12
1.96
1.98
2.02
Total
Syst.
KW†
57 (13.9)
57 (13.9)
33.98
33.82
33.39
34.31
34.27
33.93
34.65
34.61
34.45
Integ*
57 (13.9)
40.32
40.10
39.58
40.83
40.60
40.20
41.32
41.14
40.74
Integ*
41.32
41.14
40.52
42.06
41.59
40.96
42.75
42.37
41.72
Total
41.32
41.14
40.52
42.06
41.59
40.96
42.75
42.37
41.72
Integ*
Capacity MBtuh
40.32
40.10
39.58
40.83
40.60
40.20
41.32
41.14
40.74
Total
Capacity MBtuh
33.98
33.82
33.39
34.31
34.27
33.93
34.65
34.61
34.45
Total
Capacity MBtuh
2.69
2.74
2.81
2.57
2.62
2.68
2.46
2.50
2.57
Total
Sys.
KW†
2.78
2.84
2.92
2.65
2.70
2.78
2.53
2.57
2.65
Total
Syst.
KW†
2.25
2.29
2.36
2.14
2.18
2.25
2.03
2.07
2.14
Total
Syst.
KW†
67 (19.4)
67 (19.4)
38.16
38.19
38.09
38.50
38.59
38.55
38.83
38.97
39.00
Integ*
67 (19.4)
45.49
45.39
45.14
46.01
45.95
45.76
46.51
46.50
46.35
Integ*
48.74
48.46
47.92
49.49
49.25
48.73
50.20
50.02
49.55
Total
48.74
48.46
47.92
49.49
49.25
48.73
50.20
50.02
49.55
Integ*
Capacity MBtuh
45.49
45.39
45.14
46.01
45.95
45.76
46.51
46.50
46.35
Total
Capacity MBtuh
38.16
38.19
38.09
38.50
38.59
38.55
38.83
38.97
39.00
Total
Capacity MBtuh
2.88
2.92
3.00
2.76
2.80
2.87
2.65
2.69
2.76
Total
Sys.
KW†
2.89
2.95
3.04
2.76
2.82
2.91
2.63
2.69
2.78
Total
Syst.
KW†
2.34
2.39
2.46
2.23
2.28
2.35
2.13
2.17
2.24
Total
Syst.
KW†
19
15.85
16.10
14.91
15.19
15.44
14.21
14.48
14.73
1575
1225
1400
1575
1225
1400
1575
16.86
17.12
15.87
16.17
16.43
15.12
15.41
15.68
1600
1800
1400
1600
1800
1400
1600
1800
20.70
21.11
21.49
19.65
20.06
20.43
18.54
18.95
19.32
2000
2250
1750
2000
2250
1750
2000
2250
Total
1750
CFM
---3 ( ---19.4)
14.43
14.18
13.91
15.12
14.88
14.60
15.75
15.51
15.24
Integ*
17.77
17.44
17.06
18.80
18.45
18.07
19.77
19.43
19.04
Integ*
3.65
3.60
3.56
3.50
3.46
3.42
3.37
3.32
3.28
Total
Syst.
KW†
2.97
2.94
2.92
2.85
2.82
2.80
2.74
2.71
2.69
Total
Syst.
KW†
2.59
2.58
2.57
2.45
2.43
2.42
2.31
2.30
2.29
Total
Syst.
KW†
7 ( ---13.9)
17.91
17.65
17.35
18.54
18.27
17.97
19.13
18.87
18.56
Integ*
7 ( ---13.9)
19.32
19.04
18.71
20.01
19.73
19.40
20.64
20.36
20.04
Integ*
25.85
25.43
24.96
26.91
26.49
26.01
27.92
27.50
27.02
Total
23.76
23.37
22.94
24.73
24.34
23.91
25.66
25.28
24.83
Integ*
Capacity MBtuh
21.03
20.72
20.36
21.77
21.47
21.11
22.46
22.16
21.81
Total
Capacity MBtuh
19.49
19.21
18.88
20.17
19.88
19.56
20.82
20.53
20.20
Total
Capacity MBtuh
7 ( ---13.9)
3.79
3.75
3.72
3.63
3.59
3.57
3.49
3.45
3.42
Total
Syst.
KW†
3.08
3.06
3.04
2.96
2.93
2.92
2.85
2.82
2.81
Total
Syst.
KW†
2.72
2.71
2.71
2.59
2.58
2.58
2.47
2.46
2.45
Total
Syst.
KW†
32.79
32.33
31.79
33.81
33.34
32.79
34.77
34.30
33.72
Total
Total
Syst.
KW†
2.87
2.87
2.87
2.75
2.74
2.75
2.66
2.65
2.65
27.11
26.86
26.53
27.56
27.27
26.97
27.98
27.70
27.39
3.06
3.06
3.08
2.93
2.94
2.95
2.82
2.82
2.83
35.86
35.49
35.07
36.43
36.05
35.61
37.01
36.63
36.17
32.63
32.30
31.91
33.15
32.81
32.40
33.68
33.33
32.92
3.20
3.18
3.18
3.07
3.06
3.05
2.95
2.94
2.93
29.90
29.47
28.98
30.82
30.39
29.90
31.71
31.27
30.75
3.92
3.90
3.88
3.76
3.73
3.72
3.60
3.58
3.56
3.21
3.22
3.25
3.08
3.09
3.12
2.96
2.97
3.00
Total
Syst.
KW†
Total
Integ*
Capacity MBtuh
27 ( ---2.8)
Total
Syst.
KW†
Total
Integ*
Capacity MBtuh
37 (2.8)
30.10
28.99
28.43
30.63
30.31
29.94
31.07
30.79
30.44
3.36
3.33
3.34
3.23
3.23
3.24
3.10
3.10
3.11
39.81
39.43
38.98
40.41
40.02
39.54
40.98
40.59
40.13
36.23
35.88
35.48
36.77
36.42
35.98
37.29
36.94
36.52
3.50
3.51
3.54
3.36
3.37
3.39
3.21
3.22
3.25
27 ( ---2.8)
37 (2.8)
40.31
39.76
39.14
41.39
40.83
40.18
43.47
42.09
41.23
35.80
35.31
34.76
36.76
36.26
35.69
38.61
37.39
36.62
4.06
4.05
4.06
3.89
3.88
3.88
3.77
3.72
3.72
49.45
49.00
48.41
50.19
49.67
49.10
50.91
50.38
49.82
45.00
44.59
44.05
45.68
45.20
44.68
46.33
45.85
45.33
4.26
4.27
4.30
4.08
4.08
4.11
3.90
3.90
3.93
Total
Syst.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
33.89
32.64
32.01
34.48
34.13
33.71
34.99
34.67
34.27
Total
Syst.
KW†
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
30.53
30.24
29.87
31.04
30.71
30.36
31.50
31.19
30.84
Total
Total
Capacity MBtuh
Capacity MBtuh
Syst.
Syst.
Integ*
Total
Integ*
Total
Integ*
KW†
KW†
215BNA060---A Outdoor Section With FX4DNF061 Indoor Section
17 ( ---8.3)
24.32
24.00
23.61
25.03
24.70
24.31
25.69
25.36
24.99
Integ*
Capacity MBtuh
26.68
26.32
25.89
27.45
27.09
26.66
28.17
27.81
27.40
Total
37 (2.8)
215BNA048---A Outdoor Section With FX4DNF049 Indoor Section
17 ( ---8.3)
22.41
22.10
21.74
23.13
22.73
22.39
24.21
23.95
23.63
Capacity MBtuh
24.58
24.24
23.85
25.36
24.93
24.56
26.55
26.26
25.92
Total
27 ( ---2.8)
OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C)
Total
Total
Capacity MBtuh
Capacity MBtuh
Syst.
Syst.
Integ*
Total
Integ*
Total
Integ*
KW†
KW†
215BNA042---A Outdoor Section With FX4DNF043 Indoor Section
Capacity MBtuh
17 ( ---8.3)
47 (8.3)
47 (8.3)
41.79
41.35
40.82
42.45
42.00
41.46
43.12
42.66
42.10
Integ*
47 (8.3)
46.28
45.81
45.26
46.98
46.50
45.93
47.66
47.18
46.61
Integ*
57.47
56.88
56.16
58.34
57.72
57.00
59.23
58.60
57.86
Total
57.47
56.88
56.16
58.34
57.72
57.00
59.23
58.60
57.86
Integ*
Capacity MBtuh
46.28
45.81
45.26
46.98
46.50
45.93
47.66
47.18
46.61
Total
Capacity MBtuh
41.79
41.35
40.82
42.45
42.00
41.46
43.12
42.66
42.10
Total
Capacity MBtuh
4.43
4.45
4.50
4.24
4.26
4.30
4.06
4.07
4.12
Total
Syst.
KW†
3.65
3.67
3.72
3.49
3.52
3.56
3.34
3.37
3.41
Total
Syst.
KW†
3.36
3.38
3.43
3.22
3.25
3.29
3.10
3.12
3.16
Total
Syst.
KW†
57 (13.9)
57 (13.9)
48.46
47.91
47.26
49.27
48.69
48.00
50.13
49.49
48.79
Integ*
57 (13.9)
53.84
53.21
52.30
54.63
54.09
53.20
55.35
54.95
54.13
Integ*
67.20
66.27
65.21
68.30
67.32
66.31
69.29
68.57
67.41
Total
67.20
66.27
65.21
68.30
67.32
66.31
69.29
68.57
67.41
Integ*
Capacity MBtuh
53.84
53.21
52.30
54.63
54.09
53.20
55.35
54.95
54.13
Total
Capacity MBtuh
48.46
47.91
47.26
49.27
48.69
48.00
50.13
49.49
48.79
Total
Capacity MBtuh
4.61
4.66
4.76
4.40
4.46
4.55
4.21
4.25
4.34
Total
Syst.
KW†
3.78
3.84
3.93
3.61
3.66
3.76
3.45
3.50
3.58
Total
Syst.
KW†
3.51
3.55
3.61
3.37
3.40
3.46
3.21
3.26
3.32
Total
Syst.
KW†
67 (19.4)
67 (19.4)
56.22
55.73
54.86
56.99
56.54
55.78
57.72
57.34
56.67
Integ*
67 (19.4)
61.52
61.21
60.68
62.29
62.01
61.54
63.02
62.79
62.36
Integ*
77.54
76.93
76.04
78.62
78.01
77.15
79.67
79.11
78.26
Total
77.54
76.93
76.04
78.62
78.01
77.15
79.67
79.11
78.26
Integ*
Capacity MBtuh
61.52
61.21
60.68
62.29
62.01
61.54
63.02
62.79
62.36
Total
Capacity MBtuh
56.22
55.73
54.86
56.99
56.54
55.78
57.72
57.34
56.67
Total
Capacity MBtuh
4.83
4.89
4.99
4.63
4.68
4.78
4.43
4.49
4.58
Total
Syst.
KW†
3.95
4.02
4.11
3.78
3.84
3.94
3.60
3.67
3.76
Total
Syst.
KW†
3.62
3.68
3.79
3.45
3.51
3.61
3.30
3.36
3.45
Total
Syst.
KW†
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
EDB — Entering Dry Bulb
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
---3 ( ---19.4)
Capacity MBtuh
16.57
Total
1400
CFM
13.55
13.32
13.08
14.20
13.98
13.71
14.81
14.58
14.35
Integ*
Capacity MBtuh
15.59
Total
1400
INDOOR AIR
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
---3 ( ---19.4)
Capacity MBtuh
1225
CFM
INDOOR AIR
75
(23.9)
70
(21.1)
65
(18.3)
EDB
° F (° C)
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE CONTINUED
GUIDE SPECIFICATIONS
GENERAL
System Description
AIR--COOLED, SPLIT--SYSTEM HEAT PUMP
215B
1--1/2 TO 5 NOMINAL TONS
Fans
Outdoor--mounted, air--cooled, split--system heat pump unit
suitable for ground or rooftop installation. Unit consists of a
hermetic compressor, an air--cooled coil, propeller--type condenser
fan, and a control box. Unit will discharge supply air upward as
shown on contract drawings. Unit will be used in a refrigeration
circuit to match up to a packaged fan coil or coil unit.
—
—
—
—
—
Quality Assurance
—
—
—
—
—
—
—
Unit will be rated in accordance with the latest edition of
AHRI Standard 240.
Unit will be certified for capacity and efficiency, and
listed in the latest AHRI directory.
Unit construction will comply with latest edition of
ANSI/ ASHRAE and with NEC.
Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit
will have C--UL approval.
Unit cabinet will be capable of withstanding Federal Test
Method Standard No. 141 (Method 6061) 500--hr salt
spray test.
Air--cooled condenser coils are pressure tested and the
outdoor unit is leak tested.
Unit constructed in ISO9001 approved facility.
Compressor
—
—
Unit will be shipped as single package only and is stored
and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
—
—
—
—
—
U.S. and Canada only.
—
Factory assembled, single piece, air--cooled heat pump
unit. Contained within the unit enclosure is all factory
wiring, piping, controls, compressor, refrigerant charge
Puronr (R--410A), and special features required prior to
field start--up.
—
Unit Cabinet
Unit cabinet will be constructed of galvanized steel,
bonderized, and coated with a powder coat paint.
Refrigeration circuit components will include liquid--line
shutoff valve with sweat connections, vapor--line shutoff
valve with sweat connections, system charge of Puronr
(R--410A) refrigerant, POE compressor oil, accumulator,
and reversing valve.
Operating Characteristics
Equipment
—
Condenser coil will be air cooled.
Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned,
dehydrated, and sealed.
Refrigeration Components
PRODUCTS
—
Compressor will be hermetically sealed.
Compressor will be mounted on rubber vibration
isolators.
Condenser Coil
Delivery, Storage, and Handling
—
Condenser fan will be direct--drive propeller type,
discharging air upward.
Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings.
Shafts will be corrosion resistant.
Fan blades will be statically and dynamically balanced.
Condenser fan openings will be equipped with steel wire
safety guards.
The capacity of the unit will meet or exceed _____ Btuh
at a suction temperature of _____ _F/_C. The power
consumption at full load will not exceed _____ kW.
Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____ Btuh
or greater at conditions of _____ CFM entering air
temperature at the evaporator at _____ _F wet bulb and
_____ _F/_C dry bulb, and air entering the unit at _____
_F/_C.
The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
Electrical Requirements
—
—
—
Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v to
_____ v.
Unit electrical power will be single point connection.
Control circuit will be 24v.
Special Features
—
20
Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
SYSTEM DESIGN SUMMARY
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc.
Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C).
Maximum outdoor operating air temperature for cooling mode is 125_F (51.7_C).
Minimum outdoor operating air temperature for heating mode is –10_F (–23_C).
Maximum outdoor operating air temperature for heating mode is 66_F (18.9_C).
For reliable operation, unit should be level in all horizontal planes.
For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or elevation differences between indoor and outdoor units
greater than 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor.
If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4
mm).
Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
Do not apply capillary tube indoor coils to these units.
Factory--supplied filter drier must be installed.
21
EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
Edition Date: 08/17
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
22
Catalog No. PDS215B---04
Replaces: PDS215B--- 03
Download PDF
Similar pages