7500R Series Data Center Switch Router
Data Sheet
Product Highlights
!
Performance
• 115 Terabits per second fabric capacity
• Up to 51 billion packets per second
• Up to 9.6 Terabit per second per slot
• Up to 432 wire-speed 100GbE ports
• 10GbE, 25GbE and 50GbE mode support
• Under 4 microsecond latency (64 bytes)
• 200GbE and 400GbE Ready
High Hardware Availability
• N+N Grid redundant power system
• 1+1 Supervisor redundancy
• N+1 Fabric module redundancy
• N+1 Fan module redundancy
Virtualization and Provisioning
!
• CloudVision
• VXLAN for next generation DC
• LANZ for microburst detection
• VM Tracer
• Zero Touch Provisioning (ZTP)
• Advanced Event Monitoring
• sFlow (RFC3176)
• IEEE 1588 PTP
Scalable Architecture
• Dense 40GbE and 100GbE
• Flexible support for 25GbE and 50GbE
• Deep packet buffer (24GB per line card)
• 13,824 Virtual Output Queues per port to
eliminate head of line blocking
Overview
!
The Arista 7500R Series of purpose built modular switches deliver the industry’s
highest performance with 115Tbps of system throughput to meet the needs of the
largest scale data centers. They combine scalable L2 and L3 resources and high
density with advanced features for network monitoring, precision timing and
network virtualization to deliver scalable and deterministic network performance
while simplifying designs and reducing Opex.
!
The 7500R can be deployed in a wide range of open networking solutions
including large scale layer 2 and layer 3 cloud designs, overlay networks, virtualized
or traditional enterprise data center networks. Deep packet buffers and large
routing tables allow for internet peering applications and provides complete
deployment flexibility.
!
Available in a compact system design, as a choice of 12, 8 and 4 slot, the Arista
7500R is the next generation of the 7500 Series and delivers seamless upgrades
ensuring investment protection of fabric modules, line cards and supervisor
modules while setting a new standard for performance, density, reliability, and
power efficiency. The 7500R can support up to 432 ports of wire speed 100GbE and
40GbE and offers over 115 Tbps of total capacity with a broad choice of line cards.
Every 100GbE interface supports a choice of 5 speeds including 25GbE and 50GbE
providing unparalleled flexibility and the ability to seamlessly transition data centers
to the next generation of Ethernet performance.
!
All components are hot swappable, with redundant supervisor, power, fabric and
cooling modules with front-to-rear airflow. The system is purpose built for data
centers and is energy efficient with typical power consumption of under 25 watts
per 100GbE port for a fully configured chassis. These attributes make the Arista
7500R an ideal platform for building reliable and highly scalable data center
networks.
Resilient Control Plane
• Multi-core Hyper-threaded x86 CPU
• 32GB DRAM / 4GB Flash
• Dual Supervisor modules
• User applications can run in a VM
Data Center Class Design
• AC and DC power options
• Front-to-rear airflow for optimized cooling
• 25W per 100GbE port typical power
• Up to 864 100GbE ports per 42U rack
Arista Extensible Operating System
• Single binary image
• Fine-grained truly modular network OS
• Stateful Fault Containment (SFC)
• Stateful Fault Repair (SFR)
• Full access to Linux shell and tools
• Extensible platform - bash, python, C++ ,
GO, OpenConfig
Arista 7500R Series Modular Data Center Switches
Arista EOS
!
All Arista products including the 7500R Series runs the same Arista EOS software,
binary image simplifying network administration with a single standard across all
switches. Arista EOS is a modular switch operating system with a unique state
sharing architecture that cleanly separates switch state from protocol processing
and application logic. Built on top of a standard Linux kernel, all EOS processes run
in their own protected memory space and exchange state through an in-memory
database. This multi-process state sharing architecture provides the foundation for
in-service-software updates and self-healing resiliency together with stateful
switchover without the loss of data plane forwarding.
!
Arista EOS enables advanced monitoring and automation capabilities such as Zero
Touch Provisioning, LANZ, VM Tracer and Linux based tools to be run natively on the
switch.
7500R Series | Technical Specifications
Software Defined Cloud Networks
Arista Software Defined Cloud Networking (SDCN), combines the principles that have made cloud computing the unstoppable force
that it is: automation, self service provisioning, and linear scaling of both performance and economics coupled with the trend in
Software Defined Networking that delivers: network virtualization, custom programmability, simplified architectures, and lower capital
expenditure. This combination creates a best-in-class software foundation for maximizing the value of the network to both the
enterprise and service provider data center. A new architecture for the most mission-critical location within the IT infrastructure that
simplifies management and provisioning, speeds up service delivery, lowers costs and creates opportunities for competitive
differentiation, while putting control and visibility back in the hands of the network and systems administrators.
!
The Four Pillars of Arista's Software Defined Cloud Networking:
Universal Cloud Network
• Scalable standards-based MLAG at Layer 2, ECMP for Layer 3 and VXLAN for network virtualization flexibility
• Non blocking leaf-spine for 50K-300K hosts
Cloud Control
• Standards based EOS with AEM, ZTP/ZTR, LANZ and DANZ
• Automated Monitoring for visibility and telemetry
Network Wide Virtualization
• Multi-vendor API Support with eAPI
• Support for VMWare and NSX with VXLAN and VMTracer
• Support for Microsoft OMI and Openstack OVSDB
Network Applications and Automated Management
!
• Single point of network-wide state with Arista CloudVision
• Networked applications for workload mobility, smart systems rollback and upgrades and workflow telemetry
• Open Partner integration
Scaling Data Center Performance
The Arista 7500R Series deliver non-blocking switching capacity that enables dramatically faster and simpler network designs for data
centers and lower both capital and operational expenses. A wide range of modular systems with a single consistent EOS allows for
flexible selections at all tiers of the network and deployment scenarios including layer 2 MLAG, layer 3 ECMP, VXLAN Overlay and
Internet Peering.
!
Arista’s Multi-Chassis Link Aggregation (MLAG) technology supports a leaf and spine active/active L2 network topology. An Equal
Cost Multi-Path (ECMP) design at Layer 3 scales the network in a fully non-blocking, low-latency, two-stage network that provides
predictable and consistent application performance. The flexibility of the L2 and L3 multi-path design options combined with support
for open standards provides maximum flexibility, scalability and network wide virtualization that scales to hundreds of thousands of
hosts in a single two-tier design. Both designs support overlay networks via VXLAN and can integrate with standards-based overlay
controller solutions.
!
The Arista 7500R Series FlexRoute engine provides the flexible scalability to support deployment as a routing platform with Internet
scale routing. Arista FlexRoute along with EOS NetDB enables innovation not natively available in merchant chipsets. Arista EOS
provides operational savings through visibility, automation and improved network operations.
Peer F
ECMP Spine
Dense 100G
Peer G
Peer E
Peer D
Peer H
100G Uplinks
……….
Rack 1
Rack 2
Rack 287
Peer C
Rack 288
L2 MLAG or L3 ECMP Network
VXLAN Overlay Network
Arista Flexible Network Architectures
Internet Peering
7500R Series | Technical Specifications
Enhanced Features for High Performance Cloud Networks
The Arista 7500R delivers a suite of advanced traffic control and monitoring features to improve the agility of modern high performance
environments, with solutions for automation, data monitoring, precise timing and next-generation virtualization.
!
Automating the data center enables customers to dynamically provision computing resources in the most efficient manner while also
meeting business needs by maintaining service level agreements (SLAs). Arista EOS automates complex IT workflows and simplifies
network operations while reducing or even eliminating downtime. Arista EOS rich automation capabilities not only reduce the human
error element in network operations but also enable IT operators to make the network work the way they want.
!
!
Arista offers solutions for a variety of approaches to cloud-like network automation. Addressing the needs of the largest public cloud
environments as well as applying those lessons learned in the turnkey CloudVision automation offering.
CloudVision
CloudVision is a network-wide approach for workload orchestration and workflow automation as a turnkey solution for Cloud
Networking. CloudVision extends the EOS publish subscribe architectural approach across the network for state, topology, monitoring
and visibility. This enables enterprises to move to cloud-class automation without needing any significant internal development.
!
Arista Event Management (AEM)
Advanced Event Management (AEM), a sub-system of Arista EOS, is a powerful and flexible tool to automate tasks and customize the
behavior of EOS and the operation of the overall data center switching infrastructure. Simplifying the overall operations, AEM provides
the tools to customize alerts and actions. AEM allows operators to fully utilize the intelligence within EOS to respond to real-time events,
automate routine tasks, and automate actions based on changing network conditions.
!
Precise Data Analysis
Arista Latency Analyzer (LANZ) and Precision Data Analyzer (DANZ) are integrated features of EOS. DANZ provides a solution to
monitoring and visibility challenges at 10/40/100Gbps giving IT operations the ability to proactively deliver feedback on congestion
events, filter, replicate, aggregate and capture traffic without affecting production performance. LANZ provides precise real-time
monitoring of micro-burst and congestion events before they impact applications, with the ability to identify the sources and capture
affected traffic for analysis.
!
Precision Timing (IEEE 1588)
Arista’s hardware derived Precision Time Protocol solution provides a robust mechanism for accurate in-band time distribution in high
performance environments. The system clock can be synchronized using the Supervisor module clock input port with a PPS source or
IEEE 1588 PTP.
!
Virtualization
Supporting next-generation virtualized data centers requires tight integration with orchestration tools and emerging encapsulation
technologies such as VXLAN. The 7500R builds on the valuable tools already provided by the Arista VM Tracer suite to integrate directly
into encapsulated environments. Offering a wire-speed gateway between VXLAN and traditional L2/3 environments, the 7500R makes
integration of non-VXLAN aware devices including servers, firewalls and load-balancers seamless and provides the ability to leverage
VXLAN as a standards based L2 extension technology for non-MPLS environments.
!
Maximum Network Design Flexibility
• Scalable designs with up to a 128-way ECMP provides flexibility and balances traffic evenly across the largest leaf-spine designs
• MLAG designs are effective at almost any layer of the network and maximize cross-sectional bandwidth with fast failover times
measured in 100’s of milliseconds for link failures.
• VXLAN gateway, bridging and routing with VMTracer features to enable next generation data center designs
• Scaleable routing tables to support internet route peering
• Wide choice of dense 10G/40G/100G line cards with support for flexible 10GbE, 25GbE or 50GbE modes.
• Virtual output queue (VoQ) architecture and deep packet buffering to eliminate head of line blocking with low latency
• ACL scalability with up to 24K entries per forwarding engine and 144K ACL entries per module allows for rich policy control
• Flexible allocation of L2 and L3 forwarding table resources for more design choice
• PTP, sFlow, DANZ and multi-port mirroring tools provide network wide visibility and monitoring to detect traffic bursts, monitor
latency and congestion and allow capacity planning to improve application performance and availability
7500R Series | Technical Specifications
System Overview
The 7500R Series offers complete investment protection with the Arista 7500E Series with seamless upgrade paths for key components
and a common system architecture that ensures long term investment protection. The following 7500R chassis options are available:
• 7512R a 12-slot 18 RU chassis that supports up to 12 line cards with both AC or DC power options
• 7508R an 8-slot 13 RU chassis that supports up to 8 line cards with both AC or DC power options
• 7508ER an 8-slot 11 RU chassis that supports up to 8 line cards with redundant AC power
• 7504R a 4-slot 7 RU chassis that supports up to 4 line cards with both AC or DC power options
• 7504ER a 4-slot 7 RU chassis that supports up to 4 line cards with redundant AC power
!
The 7500R modular chassis can accommodate any combination of the 7500E line cards or the following 7500R line cards providing a
rich choice of density and speed:
• 7500R-36CQ, a 36 port 100GbE QSFP line card with support for any combination of 10/25/40/50/100G speeds on all ports
• 7500R-36Q offers 36 ports of 40GbE with the flexibility for up to 96 ports of 10GbE using break out cables and up to six ports of
100GbE without reducing the available 40GbE ports. Each 100GbE port also offers a choice of 5 speeds.
• 7500R-48S2CQ, a high performance 1/10GbE line card with two ports of 100GbE that each support a choice of 5 speeds
!
The Arista 7500R lowers total cost of ownership as it is designed to be efficient with power per port as low as 25W per 100GbE port
which combined with front to rear cooling to optimize the data center environment produces the most reliable, dense and power
efficient modular switch.
!
7500R Deterministic Network Performance
The Arista 7500 Series uses a deep buffer virtual output queue (VOQ) architecture that eliminates head-of-line (HOL) blocking and
virtually eliminates packet drops even in the most congested network scenarios. An advanced traffic scheduler fairly allocates
bandwidth between all virtual output queues while accurately following queue disciplines including weighted fair queueing, fixed
priority, or hybrid schemes. As a result, the Arista 7500 can handle the most demanding data center requirements with ease, including
mixed traffic loads of real-time, multicast, and storage traffic while still delivering low latency.
!
7500R High Availability
The Arista 7500R Series are designed for continuous operations with system wide monitoring of both hardware and software
components, simple serviceability and provisioning to prevent single points of failure. The hardware supports high-availability with hotswap of all components with redundant supervisors, power supplies, fabric and cooling modules. Fabric N+1 redundancy provides zero
loss of performance with deterministic degradation and integrated fan systems provide dynamic temperature control combined with N
+1 redundancy. The 7500R Series offer power redundancy that supports both power source and power supply redundancy. The Arista
EOS software supports stateful failover between the dual redundant supervisors as well as self-healing stateful fault containment (SFC),
stateful fault repair (SFR) and live patching through in-service-software updates to help ensure continuous service.
!
!
7500R Series Chassis - 12-slot, 8-slot and 4-slot
The 7500R Series chassis provides room for two supervisor modules, four, eight or twelve line card
modules, grid redundant power supply modules, and six fabric modules. Supervisor and line card
modules plug in from the front, while the fabric modules are inserted from the rear. The midplane is
completely passive and provides control plane connectivity to each of the fabric and line card
modules. The system design is optimized for data center deployments with front-to-rear airflow.
Arista 7500R Series Chassis - 7512R (front), 7508R (front and rear) and 7504R (front and rear)
7500R Series | Technical Specifications
Line Card Modules
Wire-speed line cards deliver up to 51 Billion packets per second of forwarding with a distributed virtual output queue architecture and
lossless fabric that eliminates head-of-line blocking and provides fairness across all ports. Line cards contain up to 24GB of packet
memory for approximately 50msec of traffic buffer per ingress port and virtually eliminating packet drops in congestion scenarios. Line
cards connect to all fabric modules in a non-blocking full mesh.
!
The Arista 7500R systems can be populated with any combination of line cards. For environments requiring the highest performance
combined with scalability a range of speed and interface options is available with full support for industry standard connections and
comprehensive layer 2 and 3 features for flexible deployment choice.
!
Line cards support industry standard optics for both single and multi-mode fiber along with flexibility for multi-rate configurations. All
line cards support 100GbE, with built-in support for quad 10GbE or 25GbE, dual 50GbE or single 40GbE and 100GbE to ensure future
proofing for next generation network architectures. Speed changes and breakout modes are enabled independently of the other ports
on the line card. 40GbE ports allow high density 10GbE and the 10GbE SFP+ ports support 1GbE mode offering comprehensive
investment protection for both existing and new network designs.
!
! !
!!
!! !
!!
!
!
!!
!!
!
36 port 100GbE QSFP line card for broad interface choice and highest density
- Offers 36 wire speed 100G ports with QSFP100 optics
- 5 speeds for flexible 10GbE, 25GbE, 40GbE, 50GbE and 100GbE with optics or cables
- 4.32Bpps of wire speed performance with 24GB of buffer
36 port 40GbE QSFP+ line card for 10G/40G and 100GbE
- 36 x 40GbE ports with QSFP+ optics and breakout cables
- Flexible interface combination of 36 x 40GbE, 96 x 10GbE, 6 x 100GbE, 24 x 25GbE
- 1.44Bpps of wire speed performance with 8GB of buffer
48 port SFP+ for 1/10GbE and 2 port 100GbE QSFP line card
- Up to 56 10G ports per line card or 48 1/10GbE ports and 2 flexible 40G/100G ports
- Two QSFP100 ports allow choice of 2 x 100GbE, 8x 25GbE, 2 x 40GbE, or 8x 10GbE
- 720Mpps of wire speed performance with 4GB of buffer
!
Supervisor Module
The supervisor modules for the 7500R series run Arista Extensible Operating System (EOS) and handle all control plane and
management functions of the system. One supervisor module is needed to run the system and a second can be added for stateful 1+1
redundancy. Each supervisor module takes up only a half slot resulting in very efficient use of space and a higher density design. The
multi-core x86 CPU with 32GB of DRAM and an optional SSD provides the control plane performance needed to run an advanced data
center switch scaling to over 1,700 physical ports and thousands of virtual ports. A pulse per second clock input port enables
synchronizing with an external source to improve the accuracy of monitoring tools.
!
Fabric Module
At the heart of the 7500R series is the fabric. It interconnects all line cards in a non-blocking architecture irrespective of the traffic. Each
line card module connects to the fabric with multiple links and data packets are spread across the links to fully utilize the fabric capacity.
Unlike hash-based selection of fabric links, the 7500R architecture provides 100% efficient connectivity from any port to any other port
with no drops. The fabric modules are always active-active, provide N+1 redundancy and can be hot-swapped with zero performance
degradation. The Fabric Modules for the 12-slot, 8-slot and the 4-slot 7500 Series are different based on the size of the chassis and both
integrate a fan assembly for flexible and redundant cooling.
!
Power Supply Modules
The 7500R series switches are equipped with redundant and hot-swappable AC or DC power supplies with an internal variable speed
fan. The 3000W AC power supplies are Titanium climate saver rated and have an efficiency of over 94% with single stage conversion to
the internal 12V DC voltage. 3000W DC power supplies use -40 to -72V direct current inputs.
7500R Series | Features
Layer 2 Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
802.1w Rapid Spanning Tree
802.1s Multiple Spanning Tree Protocol
Rapid Per Vlan Spanning Tree (RPVST+)
4096 VLANs
Q-in-Q
802.3ad Link Aggregation/LACP
• 64 Ports / Channel
• 256 groups per system (1152 groups *)
MLAG (Multi-Chassis Link Aggregation)
• Uses IEEE 802.3ad LACP
• 128 ports per MLAG
802.1Q VLANs/Trunking
802.1AB Link Layer Discovery Protocol
802.3x Flow Control
Jumbo Frames (9216 Bytes)
IGMP v1/v2/v3 snooping
Storm Control *
802.1 AVB *
SMPTE-2059-2 *
!
Layer 3 Features
•
•
•
•
•
•
•
•
•
•
!
Static Routes
Routing Protocols: OSPF, OSPFv3, BGP, MP-BGP, IS-IS, and RIPv2
128-way Equal Cost Multipath Routing (ECMP)
VRF
Bi-Directional Forwarding Detection (BFD)
Unicast Reverse Path Forwarding (uRPF)
VRRP
Virtual ARP (VARP)
Policy Based Routing (PBR)
Route Maps
Multicast
•
•
•
•
•
!
IGMP v2/v3
Protocol Independent Multicast (PIM-SM / PIM-SSM)
PIM-BiDir *
Anycast RP (RFC 4610)
Multicast Source Discovery Protocol (MSDP)
Advanced Monitoring and Provisioning
• Latency Analyzer and Microburst Detection (LANZ)
• Configurable Congestion Notification (CLI, Syslog) *
• Streaming Events (GPB Encoded) *
• Capture/Mirror of congested traffic *
Zero
Touch Provisioning (ZTP)
•
Advanced
Mirroring
•
Port
Mirroring
(16 sessions)
•
Enhanced
Remote
Port Mirroring
•
SPAN/TAP
M:N
Aggregation
*
•
L2/3/4
Filtering
*
•
• Advanced Event Management suite (AEM)
• CLI Scheduler
• Event Manager
• Event Monitor
• Linux tools
•
•
•
•
•
!
Integrated packet capture/analysis with TCPDump
Restore and Configure from USB
RFC 3176 sFlow
Optional SSD for logging and data capture
IEEE 1588 PTP *
Virtualization Support
•
•
•
•
•
!
VXLAN Gateway (draft-mahlingam-dutt-dcops-vxlan-01)
VXLAN Tunnel Endpoint
VXLAN Bridging
VXLAN Routing (VRF, MLAG) *
VM Tracer VMware Integration
Security Features
•
•
•
•
•
•
•
•
•
!
Ingress / Egress ACLs using L2, L3, L4 fields
Ingress / Egress ACL Logging and Counters
Atomic ACL Hitless restart
Control Plane Protection (CPP)
DHCP Relay
MAC Security
TACACS+
RADIUS
ARP trapping and rate limiting
Quality of Service (QoS) Features
•
•
•
•
•
•
•
•
•
•
•
!
Up to 8 queues per port
Strict priority queueing
802.1p based classification
DSCP based classification and remarking *
Egress shaping / Weighted round robin (WRR)
Policing / Shaping
Rate limiting *
Explicit Congestion Notification (ECN) marking *
802.1Qbb Per-Priority Flow Control (PFC)
802.1Qaz Enhanced Transmission Selection (ETS)*
Data Center Bridging Extensions (DCBX)*
Network Management
•
•
•
•
•
•
•
•
•
•
•
•
•
•
CloudVision
Configuration rollback and commit
100/1000 Management Port
RS-232 Serial Console Port
USB Port
SNMP v1, v2, v3
Management over IPv6
Telnet and SSHv2
Syslog
AAA
Industry Standard CLI
Beacon LED for system identification
System Logging
Environment monitoring
* Not currently supported in EOS
7500R Series | Features
High Availability
• L2 Stateful Switcover (SSO)
• L3 Stateful Switchover (SSO)
• SSU Spine *
!
Extensibility
• Linux Tools
• Bash shell access and scripting
• RPM support
• Custom kernel modules
• Software Defined Networking (SDN)
• eAPI
• OpenStack Neutron Support
• Programmatic access to system state
• Python
• Chef
• Puppet
• C++
• eAPI
• OpenStack Neutron Plug-in support
• Native KVM/QEMU support
!
Line card Features
•
•
•
•
•
•
•
•
•
•
•
•
!
9216 Byte Jumbo Frame Support
8 Priority Queues per Port
1152 Link Aggregation Groups (LAG)
32 Ports per LAG
768K MAC Addresses
768K IPv4 Host Routes
768K IPv6 Unicast Host Routes
Over 1M IPv4 Unicast LPM Routes
Up to 768K IPv6 Unicast LPM Routes
768K Multicast Routes
24K ACL Entries per Forwarding Engine
Up to 144K ACL Entries per Line card
Fabric Features
•
•
•
•
•
•
•
•
•
!
75 Terabit/sec Capacity
9.6 Terabit/sec per Line card
6.4 Terabit/sec per Fabric Module
N+1 Redundant
Non-blocking
Virtual Output Queueing
Self-healing
Distributed Scheduler
WFQ, CIR*, ETS*, Fixed Priority
Standards Compliance
•
•
•
•
•
•
802.1D Bridging and Spanning Tree
802.1p QOS/COS
802.1Q VLAN Tagging
802.1w Rapid Spanning Tree
802.1s Multiple Spanning Tree Protocol
802.1AB Link Layer Discovery Protocol
• 802.3ad Link Aggregation with LACP
• 802.3x Flow Control
• 802.3ab 1000BASE-T
• 802.3z Gigabit Ethernet
• 802.3ae 10 Gigabit Ethernet
• 802.3ba 40 Gigabit Ethernet
• 802.3ba 100 Gigabit Ethernet
• RFC 2460 Internet Protocol, Version 6 (IPv6) Specification
• RFC 2461 Neighbor Discovery for IP Version 6 (IPv6)
• RFC 2462 IPv6 Stateless Address Autoconfiguration
• RFC 2463 Internet Control Message Protocol (ICMPv6) for the
Internet Protocol Version 6 (IPv6) Specification
• IEEE 1588-2008 Precision Time Protocol
!
SNMP MIBs
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
RFC 3635 EtherLike-MIB
RFC 3418 SNMPv2-MIB
RFC 2863 IF-MIB
RFC 2864 IF-INVERTED-STACK-MIB
RFC 2096 IP-FORWARD-MIB
RFC 4363 Q-BRIDGE-MIB
RFC 4188 BRIDGE-MIB
RFC 2013 UDP-MIB
RFC 2012 TCP-MIB
RFC 2011 IP-MIB
RFC 2790 HOST-RESOURCES-MIB
RFC 3636 MAU-MIB
RMON-MIB
RMON2-MIB
HC-RMON-MIB
LLDP-MIB
LLDP-EXT-DOT1-MIB
LLDP-EXT-DOT3-MIB
ENTITY-MIB
ENTITY-SENSOR-MIB
ENTITY-STATE-MIB
ARISTA-ACL-MIB
ARISTA-QUEUE-MIB
RFC 4273 BGP4-MIB
RFC 4750 OSPF-MIB
ARISTA-CONFIG-MAN-MIB
ARISTA-REDUNDANCY-MIB
RFC 2787 VRRPv2MIB
MSDP-MIB
PIM-MIB
IGMP-MIB
IPMROUTE-STD-MIB
SNMP Authentication Failure trap
ENTITY-SENSOR-MIB support for DOM (Digital Optical
Monitoring)
• User configurable custom OIDs
!
See EOS release notes for latest supported MIBs
* Not currently supported in EOS
7500R Series | Technical Specifications
Chassis
DCS-7512N
DCS-7508N
DCS-7504N
DCS-7508
DCS-7504
Supervisor slots
2
2
2
2
2
Linecard Slots
12
8
4
8
4
Fabric Module Slots
6
6
6
6
6
Power Supply Slots
12
8
4
4
4
31.53” x 19” x
33.4” (80.1 x 48.3 x
84.8cm) / 18RU
22.75” x 19” x 31.3”
(57.8 x 48.3 x
79.5cm) / 13RU
12.25” x 19” x 31.3”
(31.2 x 48.3 x
79.5cm) / 7RU
19.1” x 19” x 30”
(48.5 x 48.3 x
76.2cm) / 11RU
12.25” x 19” x 30”
(31.2 x 48.3 x
76.2cm) / 7RU
Weight (Chassis only)
185 lbs (84 kg)
95 lbs (43.1 kg)
76.5 lbs (34.7 kg)
95 lbs (43.1 kg)
76.5 lbs (34.7 kg)
Weight (Full System)
628 lbs (284.9 kg)
400 lbs (181.4 kg)
222 lbs (101 kg)
300 lbs (136 kg)
210 lbs (95 kg)
Maximum 10GbE Density
1,728 Ports
1,152 Ports
576 Ports
1,152 Ports
576 Ports
Maximum 25GbE Density
1,728 Ports
1,152 Ports
576 Ports
1,152 Ports
576 Ports
Maximum 40GbE Density
432 Ports
288 Ports
144 Ports
288 Ports
144 Ports
Maximum 50GbE Density
864 Ports
576 Ports
288 Ports
576 Ports
288 Ports
Maximum 100GbE Density
432 Ports
288 Ports
144 Ports
288 Ports
144 Ports
115Tbps / 51Bpps
75 Tbps / 34.5 Bpps
38 Tbps / 17.3 Bpps
75 Tbps / 34.5 Bpps
38 Tbps / 17.3 Bpps
12,896W
8,990W
4,500W
8,570W
5,086W
Physical Dimensions (HxWxD)
Maximum Throughput / PPS
Max Power Consumption
Fabric Module
DCS-7512R-FM
DCS-7508R-FM
DCS-7504R-FM
5+1
5+1
5+1
2.5” x 21” x 10.25” (6.4 x 53.3 x 26cm)
2.5” x 14” x 10.25” (6.4 x 35.6 x 26cm)
2.5” x 8.5” x 10.25” (6.4 x 21.6 x 26cm)
Weight
25 lbs (11.4 kg)
13.4 lbs (6.1 kg)
7.5 lbs (3.4 kg)
Typical Power (Maximum) *
320W (390W)
224W (298W)
121W (163W)
Yes
Yes
Yes
DCS-7512N
DCS-7508, DCS-7508N
DCS-7504, DCS-7504N
7500R-36CQ
7500R-36Q
7500R-48S2CQ
36 QSFP100
36 QSFP+
48 SFP+ and 2 QSFP100
Max 10GbE
144
96
56 (48 SFP+ and 8 Breakout)
Max 25GbE
144
24
8
Max 40GbE
36
36
2
Max 50GbE
72
12
4
Max 100GbE
36
6
2
24GB
8GB
4GB
16.1 lbs (7.3 kg)
12.5 lbs (5.7 kg)
11.5 lbs (5.2 kg)
758W (863W)
368W (406W)
202W (220W)
Redundancy
Dimensions (HxWxD)
Integrated Fan Module
Chassis Support
Linecard
Ports
Port Buffer
Weight
Typical (Max) Power *
Dimensions (WxHxD)
Chassis Support
17.5” x 1.75” x 23” (44.5 x 4.5 x 58.4cm)
DCS-7512N, DCS-7508N, DCS-7504N and DCS-7504, DCS-7508
* Typical power consumption measured at 25C ambient with 50% load on all ports
7500N Chassis are recommended for all new installations
7500R Series | Physical Characteristics
Supervisor Module
DCS-7500-SUP2
1.9Ghz, Multi Core, x86, 64-bit
Processor
Supported Optics and Cables
Interface Type
QSFP+ ports
System Memory
32 GB
40GBASE-CR4
QSFP+ to QSFP+: 0.5m-5m
Flash Storage Memory
4 GB
40GBASE-AOC
3m to 100m
RS-232 Serial Ports
One (RJ-45)
40GBASE-UNIV
150m (OM3) / 150m (OM4), 500m (SM)
100/1000 Management Ports
Two (RJ-45)
40GBASE-SRBD
100m (OM3) /150m (OM4)
Two
40GBASE-SR4
100m (OM3) / 150m (OM4)
120GB Optional
40GBASE-XSR4
300m (OM3) / 400m (OM4)
8.5” x 1.75” x 23”
(21.6 x 4.4 x 58.4cm)
40GBASE-PLRL4
1km (1km 4x10G LR/LRL)
40GBASE-PLR4
10km (10km 4x10G LR/LRL)
40GBASE-LRL4
1km
40GBASE-LR4
10km
40GBASE-ER4
40km
USB 2.0 Interface
SSD Storage
Physical Dimensions
(WxHxD)
Weight
5 lbs (2.4 kg)
Typical Power (Maximum)
80W (120W)
DCS-7508, DCS-7504, DCS-7512N, DCS-7508N
DCS-7504N
Chassis Support
Environmental Characteristics
Operating Temperature
0 to 40˚C
Storage Temperature
-40 to 70˚C (-40 to 158˚F)
Relative Humidity
5 to 95%
Operating Altitude
0 to 10,000 ft, (0-3,000m)
Standards Compliance
EMC
FCC, EN55022, EN61000-3-2, EN61000-3-3 or
EN61000-3-11, EN61000-3-12 (as applicable)
Immunity
EN55024
EN300 386
Safety
UL/CSA 60950-1, EN 60950-1, IEC 60950-1
CB Scheme with all country differences
Certifications
North America (NRTL)
European Union (EU)
BSMI (Taiwan)
C-Tick (Australia)
CCC (PRC)
MSIP (Korea)
EAC (Customs Union)
VCCI (Japan)
European
Union
Directives
2006/95/EC Low Voltage Directive
2004/108/EC EMC Directive
2011/65/EU RoHS Directive
2012/19/EU WEEE Directive
* Not currently supported in EOS
Note 1 - DCS-7508 rated to 35C with 7500R Series line cards
Interface Type
SFP+ ports
10GBASE-CR
SFP+ to SFP+: 0.5m-5m
10GBASE-CR
0.5m-5m QSFP+ to 4x SFP+
10GBASE-AOC
SFP+ to SFP+: 3m-30m
10GBASE-SRL
100m (OM3) / 150m (OM4)
10GBASE-SR
300m (OM3) /400m (OM4)
10GBASE-LRL
1km
10GBASE-LR
10km
10GBASE-ER
40km
10GBASE-ZR
80km
10GBASE-DWDM
80km
100Mb TX, 1GbE SX/LX/TX
Yes
Interface Type
100G QSFP Ports
100GBASE-SR4
70m OM3 / 100m OM4 Parallel MMF
100GBASE-LR4
10km SM Duplex
100GBASE-LRL4
2km SM Duplex
100GBASE-CWDM4
2km SM duplex
100GBASE-AOC
3m to 30m
100GBASE-CR4
QSFP to QSFP: 1m to 5m
25GBASE-CR
QSFP to SFP25: 1m to 3m lengths
7500R Series | Physical Characteristics
Power Supply Specifications
PWR-3KT-AC-RED
PWR-3K-DC-RED
PWR-2900AC
Input Circuit (Max)
200 - 240V, 16A (20A UL)
-48-60V DC, 80A
200 - 240V, 16A (20A UL)
Input Frequency
50-60 Hz, single phase AC
DC
50-60 Hz, single phase AC
3000W
3000W
2900W
IEC 60320 C20
AWG #4 - #3
IEC 60320 C20
2.75” x 4.13” x 11.65” (7.0 x 10.5 x 29.6cm)
2.75” x 4.13” x 11.65” (7.0 x 10.5 x 29.6cm)
4.25” x 3.25” x 10” (10.8 x 8.3 x 25.4cm)
5.5 lbs (2.49 kg)
5.5 lbs (2.49 kg)
5.3 lbs (2.4 kg)
DCS-7512N, DCS-7508N, DCS-7504N
DCS-7512N, DCS-7508N, DCS-7504N
DCS-7508, DCS-7504,
Output Power
Input Connector
Size (WxHxD)
Weight
Chassis Support
7500R Series | Ordering Information
Product Number
Product Description
DCS-7512R-BND
Arista 7512R Chassis bundle. Includes 7512N chassis, 8x3kW PS, 6xFM-R, 1xSup2
DCS-7508R-BND
Arista 7508R Chassis bundle. Includes 7508N chassis, 6x3kW PS, 6xFM-R, 1xSup2
DCS-7504R-BND
Arista 7504R Chassis bundle. Includes 7504N chassis, 4x3kW PS, 6xFM-R, 1xSup2
DCS-7512R-BND-DC
Arista 7512R DC Chassis bundle. Includes 7512N chassis, 8xDC PS, 6 FM-R, 1xSup2
DCS-7508R-BND-DC
Arista 7508R DC Chassis bundle. Includes 7508N chassis, 6xDC PS, 6 FM-R, 1xSup2
DCS-7504R-BND-DC
Arista 7504R DC Chassis bundle. Includes 7504N chassis, 4xDC PS, 6 FM-R, 1xSup2
DCS-7508ER-BND
Arista 7508ER Chassis bundle. Includes 7508 chassis, 4xAC PS, 6xFM-R, 1xSup2
DCS-7504ER-BND
Arista 7504ER Chassis bundle. Includes 7504 chassis, 4xAC PS, 6xFM-R, 1xSup2
DCS-7500-SUP2
Supervisor-2 module for 7500 Series (spare)
DCS-7500-SUP2-D
Supervisor-2 module for 7500 Series, with SSD (spare)
DCS-7500R-36CQ-LC
7500R Series 36 port 100GbE QSFP100 wirespeed line card
DCS-7500R-36Q-LC
7500R Series 36 port 40GbE QSFP+ (6 port 100GbE) wirespeed line card
DCS-7500R-48S2CQ-LC
7500R Series 48 port 1/10GbE SFP+ and 2 port 100GbE QSFP wirespeed line card
Optional Components and Spares
DCS-7512N-CH
Arista 7512N chassis, 2 supervisor slots, 12 line card slots, 6 fabric slots, AC or DC power (ordered separately)
DCS-7508N-CH
Arista 7508N chassis, 2 supervisor slots, 8 line card slots, 6 fabric slots, AC or DC power (ordered separately)
DCS-7504N-CH
Arista 7504N chassis, 2 supervisor slots, 4 line card slots, 6 fabric slots, AC or DC power (ordered separately)
DCS-7508-CH
Arista 7508 chassis, 2 supervisor slots, 8 line card slots, 6 fabric slots
DCS-7504-CH
Arista 7504 chassis, 2 supervisor slots, 4 line card slots, 6 fabric slots
DCS-7512R-FM
7500R Series Fabric (integrated fan) Module for 7512 Chassis, required for fabric slots 1-6
DCS-7508R-FM
7500R Series Fabric (integrated fan) Module for 7508 and 7508N Chassis, required for fabric slots 1-6
DCS-7504R-FM
7500R Series Fabric (integrated fan) Module for 7504 and 7504N Chassis, required for fabric slots 1-6
DCS-7500-SCVR
Blank cover for 7500 supervisor slot
DCS-7500-LCVR
Blank cover for 7500 line card slot
LIC-MOD-1-E
Enhanced Software License for Arista Modular switches - 4 slots (OSPF, BGP, ISIS, PIM)
LIC-MOD-2-E
Enhanced Software License for Arista Modular switches - 8 to 16-slots (OSPF, BGP, ISIS, PIM)
LIC-MOD-1-V
Virtualization license for Arista Modular switches - 4 slots (VM Tracer and VXLAN)
LIC-MOD-2-V
Virtualization license for Arista Modular switches - 8 to 16-slots (VM Tracer and VXLAN)
LIC-MOD-1-Z
Monitoring & provisioning license for Arista Modular switches - 4 slots (ZTP, LANZ, API, TapAgg)
LIC-MOD-2-Z
Monitoring & provisioning license for Arista Modular switches - 8 to 16-slots (ZTP, LANZ, API, TapAgg)
LIC-MOD-1-FLX
Expanded L3 License for Arista Modular switches, 4 slots - Over 256K Routes, MPLs and VXLAN
LIC-MOD-2-FLX
Expanded L3 License for Arista Modular switches, 8 slots - Over 256K Routes, MPLs and VXLAN
LIC-MOD-3-FLX
Expanded L3 License for Arista Modular switches, 12 slots - Over 256K Routes, MPLs and VXLAN
Note:
- Arista 7500 and 7500N switches ship with four, six or 8 C19-C20 power cables (2m). Other power cables must be ordered separately
- Front-to-rear means the air flows from the switch port side to the fan side
7500R Series | Contact Information
Optional Components and Spares
PWR-3KT-AC-RED
Spare 3kW Titanium AC Power Supply for 7300 and 7500N series (red handle)
PWR-3K-DC-RED
Spare 3kW DC Power Supply for 7300 and 7500N series (red handle)
PWR-2900AC
2900W AC power supply for 7500 series (7508 and 7504 chassis)
DCS-7300-PCVR
Blank cover for 7300 and 7500N power supply slot
KIT-7512
Spare accessory kit for Arista 7512N. Includes 8xC19-C20 power cords, 2 & 4 post mounting brackets
KIT-7508
Spare accessory kit for Arista 7508 and 7508N. Includes 4xC19-C20 power cords, 2 & 4 post mounting brackets
KIT-7504
Spare accessory kit for Arista 7504 and 7504N. Includes 4xC19-C20 power cords, 2 & 4 post mounting brackets
CAB-C19-C20
Power cord, C19 to C20 (2m)
CAB-C19-L6-20
Power cord, C19 to L6-20 (2.5m)
Warranty
The Arista 7500R Series switches come with a one-year limited hardware warranty, which covers parts, repair, or replacement with a 10
business day turn-around after the unit is received.
!
Service and Support
Support services including next business day and 4-hour advance hardware replacement are available. For service depot locations,
please see: http://www.arista.com/en/service
Headquarters
Support
Sales
5453 Great America Parkway
Santa Clara, California 95054
408-547-5500
support@arista.com
408-547-5502
866-476-0000
sales@arista.com
408-547-5501
866-497-0000
www.arista.com
Copyright 2016 Arista Networks, Inc. The information contained herein is subject to change without notice. Arista, the
Arista logo and EOS are trademarks of Arista Networks. Other product or service names may be trademarks or service marks
of others.
6/2016