Key Benefits
• Proactively monitor the broadband network in order to
detect problems before it affects customers
• 24/7 monitoring system with alarms and notifications
which informs the user immediately when an
impairment is detected
• Reduce OPEX by analyzing multiple return and forward
paths simultaneously
• Real-time monitoring of the entire network from a PC
The Kingstone monitoring system offers real-time simultaneous signal monitoring and analysis on multiple return and forward paths of HFC
networks. The DS1610 system is capable of capturing any transient noise and ingress noise and includes alarm setting, data storage, data analysis,
data comparison in 3D and video recording, simplifying the installation, maintenance and troubleshooting of HFC networks. The user is also able
to log in through any PC, enabling remote monitoring of the plant.
System Configuration
Standard Configuration
DS1610
Optional Modules
Housing with built-in Local Management Software
DS1610-1D
Return Path Monitor Card
DS1610 Server Software
DS1615
RF FSK Modulator
DS1610 Client Management Software
DS8831H
Spectrum Analyzer
Software Interface
www.deviserinstruments.com
DS1610 "KingStone" Broadband Network Monitoring System
1. Return Path Monitoring Solution
2. Return & Forward Path Debugging and Troubleshooting Solution
www.deviserinstruments.com
2
DS1610 "KingStone" Broadband Network Monitoring System
Specifications
DS1610-1D8/16/24/32
Frequency
Range
0.5 MHz ~ 86 MHz
Span
0 ~ 86 MHz
Sweep Time
≤1 ms (Full Span)
RBW
30 kHz ~ 300 kHz 1-3 Step
VBW
30 kHz ~ 300 kHz 1-3 Step
Amplitude
Level
Max. Safe Input
Displayed Average Noise Level
Attenuator
+110 dBμV 25 V DC
≤18 dBμV, 5 MHz ~ 65 MHz(No Input Signal, 0dB Attenuation,
300 kHz RBW, 30 kHz VBW, Sampling Demodulation)
Range
0 dB ~ 30 dB
Step
1 dB
Spurious Responses
Second Harmonic
<-55 dBc for +80 dBμV Signal at input mixer
Third Order Intermodulation
<-55 dBc for two +80 dBμV Signals at input mixer with ≥1MHz Separation, Amplifier Off
Display
Logarithm Scale
0.1 ~ 0.9 dB/div at 0.1 dB Step: 1 ~ 40 dB/div at 1 dB Step
Linear Scale
8 Divisions
Scale Unit
dBm, dBmV, dBμV
Trace Detector
MAX, MIN, Average
Reference Level
0 dBμV ~ +140 dBμV
Level Accuracy
Typical ≤±1.5 dB@+20 ℃
Others
Working Temperature
0 ℃ ~ +40 ℃
Storage Temperature
-10 ℃ ~ +50 ℃
Structure
1U Rack
Power Supply
AC 220 V / 50 Hz
RF Frequency
87 MHz ~ 120 MHz
Output
85 dBuV ~ 110 dBuV, 1 dB Step
Modulation Type
FSK (±67 kHz)
Data Baud Rate
38.4 kbps
Port to connect DS1610
RS232
DS1615
©2014 Deviser Instruments Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131 . All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of their
respective corporations. Deviser Instruments manufacturing facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Deviser Instruments.TC702 140921
www.deviserinstruments.com
3
Broadband
DS2400Q
QAM Analysis Multifunction
Key Benefits
•Comprehensive tool for construction and installation of cable
networks
•Automatically learns channel plan from cable drop
•A rugged, handheld unit for field use
•Auto test with pass/fail limits speed up tests and simplifies
result interpretation
•Toolbox management software enables user to quickly
configure the unit
The DS2400Q is a multifunction instrument, which supports QAM
constellation and analog signals for CATV networks. It is the ideal tool
for initial network construction, for subscriber installations as well as
for service and troubleshooting tasks. Its ruggedized design, which
includes a shock protector, combined with icon display GUI and auto
pass/fail specified limit feature provides increased efficiency and
productivity for all types of technicians.
Other features such as return path & forward spectrum scan, 12
favorite tilt frequencies, AC line voltage test, HUM and DC voltage
measurements, combined with complete data logging and a
management software, makes this unit a versatile tool for cable
installations.
MER, PRE & Post BER measurements and BER statistics feature allows
quick testing of loose connections related to pixelating or slow DS
internet data flow. This function can identify mismatches caused by
open coaxial lines or corroded devices.
Key Features
•5 MHz ~1 GHz range (analog/digital signals)
•Pass/Fail limit test functions w/AUTO storage
•Multiple user channel plans with learn mode
•Tilt measurements display (12 frequencies)
•QAM, QPSK, COFDM power measurements
•AC-DC voltage measurements including HUM
•QAM MER w/constellation display
•Measurement data storage capability
•Pre and Post BER analysis
•User-friendly operation (ICON-GUI) •BER, ES, SES, COR/UNCOR bps
•Color display 2.8” (320×240 TFT LCD)
•Return Path & FWD spectrums scan
•Management PC software included – Toolbox
www.deviserinstruments.com
DS2400Q QAM Analysis Multifunction Meter
MER with Pre & Post Ber
Scan Test
ES & SES = CORR & UNCORR
TilT (Max 12 Freg.)
Return Path Spectrum (5-65)
Foward Spectrum
www.deviserinstruments.com
www.deviserinstruments.com
2
DS2400Q QAM Analysis Multifunction Meter
Features
Five Multi-user Defined Channel Plans
Auto Diagnostic User-defined Limit Test (Pass/Fail)
QAM Analysis and Channel Measurements
User-defined Tests
Several technicians or contractors work with more than one HFC network
and it is very practical to have different channel lineups to choose from.
The unit allows up to five (5) different user defined channel plans.
Analog, digital and custom frequencies can be configured in the unit
by using the automated learned channel plan from an RF drop or by
downloading from the PC file using the Toolbox software. The user can
select up to 12 frequencies in each of the 5 user defined plans and assign
them to a favorite/tilt channel plan.
MER plus PRE & Post BER measurements with a several time slots
(5 minutes, 15 minutes, 30 minutes, 60 minutes, 2 hours, 6 hours, 12
hours, 24 hours, and 48 hours) can be analyzed with the DS2400. This
includes viewing of the constellation diagram. The unit is compatible
with 16/32/64/128/256 QAM modulation and provides power
measurements feature of QPSK and COFDM digital carriers.
Spectrum Analysis and Measurements
The auto test simplifies the test by displaying pass/fail results. The pass/
fail limit can be set for Power levels, MER, PRE-BER, POST-BER, Spectrum
Analysis, Tilt, and HUM measurements. With its simple save function,
the technician will no longer be required to manually take note of the
results. As a result, more installations or service calls may be performed
in a day. Additionally, every measurement is recorded; there is no room
for errors. This forces performance accountability of each location, thus
avoiding churn, which may be costly to the organization.
The five (5) channel plans and the ability to group various tests, which
can be performed with a simple icon selection, enables the technician
to be very efficient and productive. The tests include Level, Tilt, Spectrum
Analysis, HUM and Performance related Test Limits for both analog and
digital carriers.
Once the test data results are stored in the instrument, they can be
recalled, viewed, and analyzed.
The DS2400Q has a spectrum mode, which allows viewing of the full
spectrum. For troubleshooting reverse path challenges, the unit can set
to display 5 to 65 MHz frequency spans providing an additional feature
to the technician when dealing with upstream data signals. The marker
function is included with the spectrum mode and transient anomalies
can be captured with the max hold feature.
File Management - Test Data Storage
The DS2400Q supports 160 channels scanning function allowing
testing the flatness and the amplitude of the HFC network quickly.
With the help of the marker, the technician can quickly determine
the anomalies related to mismatches caused by poor grounding or
damaged transmission lines.
Voltage Measurement - Battery and Charging
Full Spectrum Scans with Marker Feature
HUM Network Measurement
The Hum measurement helps the technician identify and troubleshoot
anomalies which may result from defective capacitors, faulty line
splitters, or couplers due to lightning or excessive current overloads.
Both 60 & 120 Hz tests are performed w/400Hz LPF measurements.
Several test data can be saved and stored as analog carriers or
frequencies, QAM carriers or digital frequencies, channel scan, tilt,
frequency spectrum measurement and HUM.
The results are saved in the File Directory menu, with name of the file,
time and date. These data records may be uploaded to a PC with the
Toolbox software for reports, analysis, and printing.
The unit can measure battery voltage, trunk & distribution line voltage of
the cable system, identifying AC or DC automatically. With the intelligent
power management system, the battery provides approximately 5 hours
of continued operations when fully charged.
Standard Accessories
The DS2400Q includes the following accessories:
Protector rubber bumper, carrying bag with shoulder strap, data cable
(serial to USB), two (2) “F” connectors, AC/DC power adaptor/charger,
Toolbox software and user’s manual.
www.deviserinstruments.com
www.deviserinstruments.com
3
DS2400Q QAM Analysis Multifunction Meter
Frequency
Frequency Range
Frequency Accuracy
Frequency Resolution
Channel Type
Analog TV
Digital TV
FM Radio
Digital Channel
Demodulation type
Support
Symbol rate
Bandwidth
MER (Modulation Error Ratio)
Accuracy
BER (Bit Error Rate)
Power measurement type
Digital Channel Average Power
Level range
Constellation
Accuracy
Resolution
Display mode
Analog Level Measurement
Range
Accuracy
Resolution
Input impedance
HUM Modulation
Range
Channel Scan
Number of Channels
Scanning Speed
Scale
Zoom
Frequency Spectrum
Bandwidth
Scale
Tilt Measurement
Number of Frequencies
Limit Test Parameters
Minimum/Maximum Video Level
Minimum/Maximum Δ V/A
Minimum/Maximum Power Level
Minimum MER
Max PRE/POST BER
Auto-Test
Number of programs
Line Voltage Measurement
Range
Storage
Memory
Power
Battery
Charger
Communication Port
Adaptor
Dimensions (H x W x D) & Weight
218mm × 95mm × 49mm
(8.52” x 3.74” x 1.93”)
5 MHz to 1000 MHz
± 50 ppm (@ 20°C ±5°C)
10kHz
NTSC
QAM 16/32/64/128/256 with constellation diagram plus QPSK and COFDM
Single frequency
Standard ITU-T J.83 Annex A/B/C
QAM 16/32/64/128/256
1 MS/sec to 7 MS/sec
280 kHz to 10 MHz
39 dB (QAM)
±2.0 dB
1E¯³ to 1E¯8 before and after R-S decoding (QAM)
QAM, QPSK and COFDM
-30 dBmV to +60 dBmV
±2.0 dB from 10°C to 30°C and ±3.0 dB from -10°C to 40°C
0.1 dB
QAM 64 and QAM 256 with zoom in and zoom out capability
-35 dBmV to +60 dBmV
±1.5 dB
0.1 dB
75Ω (“F” type connector)
2% to 5%
160 channels max
5 channels per second
1, 2, 5, 10 dB/div
1X, 2X, 3X, 4X, 5X five levels of magnification or full channel scan
2.5MHz, 6.25 MHz, 12.5 MHz, 25 MHz, 62.5 MHz and full span
1 dB, 2 dB, 5 dB and 10 dB/div
maximum 12 with 0.1 dB of resolution
0 dBmV to + 30 dBmV
10 dB to 20 dB
10 dBmV to +30 dBmV
33 dB (varies with modulations and systems)
1.0 Eˉ9
Maximum 7 test parameters
0 V to 100 V (AC/DC) with accuracy of ±2 V
512K byte
11.1V 1.6AH Lithium battery (5 hours of operation)
AC 100V to 240V 50-60Hz; charge time approximately 3 hours
RS 232C (With Serial to USB data cable included)
700 grams (1.54 lb)
©2014 Deviser Instruments Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131. All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of their
respective corporations. Deviser Instruments manufacturing facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Deviser Instruments. DS2400Q Rev.1 140920
www.deviserinstruments.com
www.deviserinstruments.com
4
Broadband
DS2500Q
Digital TV QAM Analyzer
Key Benefits
• High Speed Spectrum Analysis: 4~1000MHz
• Integrated DOCSIS 3.0 Cable Modem
• Integrated Upstream Signal Generator (no FEC)
• Supports ITU--T J.83 Annex A/B/C
• Error Vector Spectrum: identifies interference signals
under QAM carriers, with no break in service
• Auto Test
Integrating multiple functions in a single handheld instrument,
the new DS2500Q is a powerful Digital TV QAM Analyzer with a
comprehensive measurement suite specifically designed for
HFC network testing, troubleshooting, and maintenance.
The DS2500Q's main functions include Enhanced Spectrum
Analysis, Analog & Digital TV analysis, DOCSIS 3.0 analysis,
Upstream Signal Generator, Ethernet testing, and Auto Test.
The revolutionary EVS function enables users to detect
coherent distortions hiding under QAM carriers - without
interrupting service. The DS2500Q supports Deviser's PC
software toolkit, included with each unit, to make data transfer
a snap.
Bright 4.3" TFT
Color LCD Screen
Field-Replaceable
Battery
LED Charge
Indicator
www.deviserinstruments.com
www.deviserinstruments.
1
DS2500Q Digital TV QAM Analyzer
High-Speed Spectrum Analysis
The DS2500Q offers enhanced spectrum analysis performance
with a frequency range of 4MHz ~ 1000MHz and sensitivity to
signals as low as -55dBmV (@300KHz).
The DS2500Q also offers Digital HUM distortion measurement,
from the fundamental frequency to 4th harmonic components.
Figure 4: Digital HUM
Figure 1: Spectrum Analysis
Figure 2: Spectrograph
Figure 5: Constellation Display
The spectrogram provides a scrolling three-dimensional
display, allowing users to track frequency and level over
time - excellent for analyzing intermittent signals.
DVB-C Signal Analysis
The DS2500Q supports the ITU-T J.83 Annex A/B/C standard,
providing Channel Power, MER, BER, Constellation, and
Digital HUM measurements.
Figure 6: BER and MER Statistical Analysis
Figure 3: DVB-C Channel Measurement
2
www.deviserinstruments.com
DS2500Q Digital TV QAM Analyzer
EVS In-service Interference Detection
Upstream Signal Generator
The Error Vector Spectrum feature can find interference
signals under a QAM carrier without service interruptions.
The Upstream signal generator can generate a CW carrier or
a QAM signal. A sweeping mode is also available.
Figure 7: The EVS mode finds narrow band interference signals
with supreme clarity and ease.
Cable Modem Measurement
The DS2500Q incorporates a standard DOCSIS 3.0 cable
modem, compatible with DOCSIS 1.X, 2.0 & 3.0. The built-in
modem supports 8x DS and 4x US bonded carriers. Figure 8
(below) shows the CM statistical info screen - including
downstream signal level, modulation type, bandwidth,
symbol rate, MER, BER, upstream signal level, symbol rate,
& UCD (Upstream Channel Descriptor). Users can select
the desired DOCSIS mode, downstream channel, and
UCD. Basic network test tools include Ping, Traceroute,
PPPoE, FTP, and Browser.
Figure 9: Upstream Signal Generator
Auto Test
The DS2500Q comes equipped with a wide range of regionstandard channel plans spanning (in part) North America,
Asia, and Europe, as well as several sets of limit profiles allowing users to design automatic tests. Tasks that can be
automated include Analog TV, Digital TV and Cable Modem
testing. Once the analyzer completes an auto test, all items
in the test results will indicate Pass or Fail according to the
limit profile. Results are automatically saved for later analysis.
Figure 10: Auto Test Project
Figure 8: DOCSIS 3.0 Statistical Information Display
www.deviserinstruments.com
33
DS2500Q Digital TV QAM Analyzer
Specifications
Downstream Spectrum Analysis
Frequency Range
4 MHz ~ 1000 MHz
Frequency Stability
± 1 PPM (0˚C ~50˚C )
Frequency Span
0 MHz ~ Full span
Frequency Step
1 kHz
Resolution Bandwidth filters (-3dB)
30kHz, 100kHz, 300kHz, 1 MHz, 3 MHz
Video Bandwidth filters
30 Hz, 100 Hz, 300 Hz, 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, 1 MHz, 3 MHz
Display Scale and Range
1, 2, 5, 10, 20 dB/Div; 8 vertical divisions
Sweep Time
20ms ~ 25s
Input Level Range
-60dBmV ~ +60dBmV
Dynamic Range
65dB (300kHz RBW)
Sensitivity
-50dBmV (300 kHz RBW, Pre-amplifier On)
Attenuation
0~40dB in 1dB steps
Pre-amplifier
Manual, 18dB Gain
Accuracy of Measurements
<±1.0dB@+25±5˚C (typical value)
Measurement Detector
Positive Peak, Negative Peak, Sample, Average, RMS
Reference Level
-80dBmV ~ +70dBmV
Markers
2 vertical markers
Upstream Spectrum Analysis
Frequency Range
4~46 MHz (DOCSIS); 4~68 MHz (Euro DOCSIS 2.0); 4~88 MHz (Euro DOCSIS 3.0);
4~120 MHz (DOCSIS 3.1); 4~210 MHz (DOCSIS 3.1)
Frequency Span
42/64/84/116/206 MHz, zero span or manual selections (max 200 MHz)
RBW
100kHz, 300kHz
VBW
30 Hz, 100 Hz, 300 Hz, 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, 1 MHz, 3 MHz
Display Scale and Range
1, 2, 5, 10, 20 dB/Div
Sweep Time
20ms ~ 25s
Input Level Range
-60dBmV ~ +60dBmV
Attenuation
Automatic, 0~40dB
Pre-amplifier
Manual, 18dB Gain
Accuracy of Measurements
<±1.0dB@+25±5˚C (typical value)
Measurement Detector
Positive Peak, Negative Peak, Sample, Average
Markers
2 vertical markers
Analog TV Measurement
4
Standards
B/G, I, D/K, L/L’, M/N
Color Standards
NTSC, PAL, SECAM
Level Measurement Range
40dBmV
Level Measurement Range
-40dBmV ~ +60dBmV
Accuracy
<±1.0dB @+25 ±5˚C (S/N >30dB)
Level Resolution
0.1dB
Resolution Bandwidth
300 kHz
CCN
>51dB (Requires +10 dBmV carrier level)
CTB/CSO
≥61dB with ±2.0dB Accuracy
HUM Measurement
1 ~ 20%: ±0.5% (1~5%): ±1.0% (5~20%)
Tilt
Up to 16 channels
Pre-amplifier
Automatic, 18dB Gain
Attenuator
Automatic, 40dB
www.deviserinstruments.com
DS2500Q Digital TV QAM Analyzer
Digital TV Measurement
Frequency Range
46 ~ 1050 MHz
Power Level Range
-30dBmV ~ +50dBmV
Level Resolution
0.1dB
Accuracy
< ±1.5dB@+25 ±5˚C (C/N>20dB)
Modulation Type
16, 32, 64, 128, 256 QAM (J.83 Annex A and C); 64, 256 QAM (J.83 Annex B)
Interleave Depth
(128, 1) ~ (128, 4) for J.83B; (12, 17) for J.83 A/C
Symbol Rate
4.0 MS/s ~ 7.0 MS/s
SNR
>43dB; Accuracy: ±2.0dB
MER
>41dB; Accuracy: ±2.0dB
BER
1E-3 ~ 1E-9
Constellation
16, 32, 64, 128, 256 QAM
Cable Modem Measurement
Supported Standards
DOCSIS 1.1, 2.0, 3.0; EuroDOCSIS 1.0, 1.1, 2.0, 3.0
Downstream Demodulation
64, 256 QAM
Downstream Frequency Range
>91 MHz (US); >100 MHz (EU)
Downstream Maximum Speed
Up to 304 Mbps (6 MHz) and 400 Mbps (8 MHz)
Downstream Channel Bonding
Up to 8 channels
Downstream Bandwidth
6 MHz / 8 MHz
Downstream Input Signal Level
-15dBmV ~ +15dBmV
Upstream Frequency Range
5 ~ 42 MHz; 5 ~ 65 MHz; 5 ~ 85 MHz
Upstream Signal Bandwidth
TDMA: 200/400/800/1600/3200/6400kHz; S-CDMA: 1600/3200/6400kHz
Upstream Output Signal Level
QAM level range: +17 to +58dBmV; QPSK level range: +17 to +61dBmV
Upstream Channel Bonding
Up to 4 channels
Upstream Maximum Speed
120 Mbps (4 channels bonding)
Upstream Signal Generator
Signal Modulation
CW, QPSK, 16 QAM, 64 QAM, 256 QAM
Symbol Rate
1.28 MS/s, 2.56 MS/s, 5.12 MS/s
MER
>38dB; Accuracy ±2dB
Frequency Range
5 MHz ~ 85 MHz
Frequency Adjustable Steps
1 MHz
Signal Level Range
8.0 ~ 58dBmV (CW, QPSK)
Level Adjustable Step
1dB
Others
RF Input
75Ω F-type connector
USB
USB 1.1
Ethernet
RJ45, 10/100T Ethernet
Display
4.3" 480x272 TFT LCD
AC/DC Adapter
100 ~ 240 V/50 ~ 60Hz (AC); 12V / 3A (DC)
Battery
Li-ion, 7.4 V/7.8Ah
Charge Time
~ 4 hours
Working Time
> 6 Hours
Dimension (W×H×L)
245mm×130mm×60mm (9.6in x 5.1in x 2.4in)
Weight
About 1.5kg (3.3 lbs)
Work Temperature
-10 ~ +50 ˚C
Storage Temperature
-20 ~ +60 ˚C
©2016 Deviser Instruments Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131. All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of
their respective corporations. Deviser Instruments manufacturing facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Deviser Instruments. DS2500Q 160113
www.deviserinstruments.com
55
Broadband
DS2580C
Digital TV QAM Analyzer
Key Benefits
• )DVW6SHFWUXP$QDO\VLVa0+]'UHDG\
• ,QWHJUDWHG'2&6,6&DEOH0RGHP
• ,QWHJUDWHG8SVWUHDP6LJQDO*HQHUDWRUQR)(&
• 6XSSRUWV,787-$QQH[$%&
• (UURU9HFWRU6SHFWUXPLGHQWLILHVLQWHUIHUHQFHVLJQDOV
XQGHU4$0FDUULHUVZLWKQREUHDNLQVHUYLFH
• $XWR7HVW
Integrating multiple functions in a single handheld instrument,
the new DS2580C is a powerful Digital TV QAM Analyzer with
a comprehensive measurement suite specifically designed
for HFC network testing, troubleshooting, and maintenance.
The DS2580C's main functions include Enhanced Spectrum
Analysis, Analog & Digital TV analysis, DOCSIS 3.0 analysis,
Upstream Signal Generator, Ethernet testing, and Auto Test.
The revolutionary EVS function enables users to detect
coherent distortions hiding under QAM carriers - without
interrupting service. The DS2580C supports Deviser's PC
software toolkit, included with each unit, to make data
transfer a snap.
www.deviserinstruments.com
www.deviserinstruments.
DS2580C Digital TV QAM Analyzer
Fast Spectrum Analysis Function
The DS2580C offers enhanced spectrum analysis performance,
with a frequency range of 4MHz ~ 1220MHz and sensitivity to
signals as low as -55dBmV (@300KHz) Docsis 3.1 ready.
The DS2580C also offers Digital HUM distortion measurement,
from the fundamental frequency to 4th harmonic components.
Figure 4: Digital HUM
Figure 1: Spectrum Analysis
Figure 5: Constellation Display
Figure 2: Spectrograph
The spectrogram provides a scrolling three-dimensional
display, allowing users to track frequency and level over
time - excellent for analyzing intermittent signals.
DVB-C Signal Analysis
The DS2580C supports the ITU-T J.83 Annex A/B/C standard,
providing Channel Power, MER, BER, Constellation, and
Digital HUM measurements.
Figure 6: MER & BER Statistical Analysis
Figure 3: DVB-C Channel Measurement
2
www.deviserinstruments.com
DS2580C Digital TV QAM Analyzer
EVS In-service Interference Detection
Upstream Signal Generator
The Error Vector Spectrum feature can find interference
signals under a QAM carrier without service interruptions.
The Upstream signal generator can generate a CW carrier or
a QAM signal, a sweeping mode is also available.
Figure 7: EVS finds narrow band interference signals
with supreme clarity and ease.
Figure 9: Upstream Signal Generator
Cable Modem Measurements
Auto Test
The DS2580C incorporates a standard DOCSIS 3.0 cable
modem, compatible with DOCSIS 1.X, 2.0 & 3.0. The built-in
modem supports 8x DS and 4x US bonded carriers. Figure 8
(below) shows the CM statistical info screen - including
downstream signal level, modulation type, bandwidth,
symbol rate, MER, BER, upstream signal level, symbol rate,
& UCD (Upstream Channel Descriptor). Users can select the
desired DOCSIS mode, downstream channel, and UCD.
Basic network test tools include Ping, Traceroute, PPPoE,
FTP, and Browser.
The DS2580C comes equipped with a wide range of regionstandard channel plans spanning (in part) North America,
Asia, and Europe, as well as several sets of limit profiles,
allowing users to design automatic tests. Tasks that can be
automated include Analog TV, Digital TV, and Cable Modem
testing. Once the analyzer completes an auto test, all items
in the test results will indicate Pass or Fail according to the
limit profile. Results are automatically saved for later analysis.
Figure 10: Auto Test Project
Figure 8: DOCSIS 3.0 Statistical Information Display
www.deviserinstruments.com
www.deviserinstruments.
3
3
DS2580C Digital TV QAM Analyzer
Specifications
Downstream Spectrum Analysis
Frequency Range
4MHz ~ 1220MHz
Frequency Stability
± 1 PPM (0˚C ~50˚C )
Frequency Span
0 MHz ~ Full span
Frequency Step
1 kHz
Resolution Bandwidth filters(-3dB)
30kHz, 100kHz, 300kHz, 1 MHz, 3 MHz
Video Bandwidth filters
30 Hz, 100 Hz, 300 Hz, 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, 1 MHz, 3 MHz
Display Scale and Range
1, 2, 5, 10, 20 dB/Div; 8 vertical divisions
Sweep Time
20ms ~ 25s
Input Level Range
-60dBmV ~ +60dBmV
Dynamic Range
65dB (300kHz RBW)
Sensitivity
-50dBmV (300 kHz RBW, Pre-amplifier On)
Attenuation
0~40dB in 1dB steps
Pre-amplifier
Manual, 18dB Gain
Accuracy of Measurements
<±1.0dB@+25±5˚C (typical value)
Measurement Detector
Positive Peak, Negative Peak, Sample, Average, RMS
Reference Level
-80dBmV ~ +70dBmV
Markers
2 vertical markers
Upstream Spectrum Analysis
Frequency Range
4~46 MHz (DOCSIS): 4~68 MHz(Euro-DOCSIS): 4~88 MHz (DOCSIS 3.0 extended);
4~120 MHz (DOCSIS 3.0 extended): 4~210 MHz (DOCSIS 3.1)
Frequency Span
42/64/84/116/206 MHz, zero span or manual selections (max 200 MHz)
RBW
100kHz, 300kHz
VBW
30 Hz, 100 Hz, 300 Hz, 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, 1 MHz, 3 MHz
Display Scale and Range
1, 2, 5, 10, 20 dB/Div
Sweep Time
20ms ~ 25s
Input Level Range
-60dBmV ~ +60dBmV
Attenuation
Automatic, 0~40dB
Pre-amplifier
Manual, 18dB Gain
Accuracy of Measurements
<±1.0dB@+25±5˚C (typical value)
Measurement Detector
Positive Peak, Negative Peak, Sample, Average
Markers
2 vertical markers
Analog TV Measurement
4
Standards
B/G, I, D/K, L/L’, M/N
Color Standards
NTSC, PAL, SECAM
Level Measurement Range
40dBmV
Level Measurement Range
-40dBmV ~ +60dBmV
Accuracy
<±1.0dB @+25 ±5˚C (S/N >30dB)
Level Resolution
0.1dB
Resolution Bandwidth
300 kHz
CCN
>51dB (Requires +10 dBmV carrier level)
CTB/CSO
≥61dB with ±2.0dB Accuracy
HUM Measurement
1 ~ 20%: ±0.5% (1~5%): ±1.0% (5~20%)
Tilt
Up to 16 channels
Pre-amplifier
Automatic, 18dB Gain
Attenuator
Automatic, 40dB
www.deviserinstruments.com
DS2580C Digital TV QAM Analyzer
Digital TV Measurement
Frequency Range
46 ~ 1050 MHz
Power Level Range
-30dBmV ~ +50dBmV
Level Resolution
0.1dB
Accuracy
< ±1.5dB@+25 ±5˚C (C/N>20dB)
Modulation Type
16, 32, 64, 128, 256 QAM (J.83 Annex A and C); 64, 256 QAM (J.83 Annex B)
Interleave Depth
(128, 1) ~ (128, 4) for J.83B; (12, 17) for J.83 A/C
Symbol Rate
SNR
4.0 MS/s ~ 7.0 MS/s
>43dB; Accuracy: ±2.0dB
MER
>41dB; Accuracy: ±2.0dB
BER
1E-3 ~ 1E-9
Constellation
16, 32, 64, 128, 256 QAM
Cable Modem Measurement
Supported Standards
DOCSIS 1.1, 2.0, 3.0; EuroDOCSIS 1.0, 1.1, 2.0, 3.0
Downstream Demodulation
64, 256 QAM
Downstream Frequency Range
>91 MHz (US); >100 MHz (EU)
Downstream Maximum Speed
Up to 304 Mbps (6 MHz) and 400 Mbps (8 MHz)
Downstream Channel Bonding
Up to 8 channels
Downstream Bandwidth
6 MHz / 8 MHz
Downstream Input Signal Level
-15dBmV ~ +15dBmV
Upstream Frequency Range
5 ~ 42 MHz; 5 ~ 65 MHz; 5 ~ 85 MHz
Upstream Signal Bandwidth
TDMA: 200/400/800/1600/3200/6400kHz; S-CDMA: 1600/3200/6400kHz
Upstream Output Signal Level
QAM level range: +17 to +58dBmV; QPSK level range: +17 to +61dBmV
Upstream Channel Bonding
Up to 4 channels
Upstream Maximum Speed
120 Mbps (4 channels bonding)
Upstream Signal Generator
Signal Modulation
CW, QPSK, 16 QAM, 64 QAM, 256 QAM
Symbol Rate
1.28 MS/s, 2.56 MS/s, 5.12 MS/s
MER
>38dB; Accuracy ±2dB
Frequency Range
5 MHz ~ 85 MHz
Frequency Adjustable Steps
1 MHz
Signal Level Range
8.0 ~ 58dBmV (CW, QPSK)
Level Adjustable Step
1dB
Others
RF Input
75Ω F-type connector
USB
USB 1.1
Ethernet
RJ45, 10/100T Ethernet
Display
4.3" 480×272 TFT LCD
AC/DC Adapter
100 ~ 240 V/50 ~ 60Hz (AC); 12V / 3A (DC)
Battery
Li-ion, 7.4 V/7.8Ah
Charge Time
~ 4 hours
Working Time
> 6 Hours
Dimension (W×H×L)
245mm×130mm×60mm (9.6in x 5.1in x 2.4in)
Weight
About 1.5kg (3.3 lbs)
Work Temperature
-10 ~ +50 ˚C
Storage Temperature
-20 ~ +60 ˚C
©2016 Deviser Instruments Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131. All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of
their respective corporations. Deviser Instruments manufacturing facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Deviser Instruments. DS2580C 160113
www.deviserinstruments.com
www.deviserinstruments.
5
5
Broadband
DS2800
Spectrum Analyzer
Key Benefits
•An all-in-one tool for installation, verification and
maintenance of cable networks
•2014
WS•
VIE
RE
DIA
M
TECHNOLO
ND
G
4
O
Y
•Ensure proper installation on the first visit reducing service
calls
•Persistence testing finds hidden transient noise under the
return path signal
•Detect interference from LTE with EVS masks
•View both the QAM and spectrum analysis simultaneously,
eliminating the need to switch between screens to obtain
the overall signal statistics
•Run in-service CTB, CSO and C/N tests with gated
measurements
•Future-proof spectrum analyzer that covers up to 210 MHz
for upstream
•Quickly identify linear distortion impairments with
equalizer, frequency response and group delay
measurements
•Automated FCC proof-of-performance test
•Long battery life of 8 hours enables all day testing
The DS2800 is truly an “all-in-one” tool for performing installation, verification and maintenance of the cable network. Its unique features, such as
persistence testing and EVS analysis, enable technicians to quickly detect and isolate impairments that were not visible in the past. The analyzer
reduces operational expenses by ensuring a proper installation on the first visit and by shortening the time during service calls.
HEADEND
OUTSIDE PLANT
CUSTOMER PREMISE
ANALOG& DIGITAL
VIDEO SIGNALS
HFC
VOD SERVER
FIBER TX/RX
PHONE
EMTA
PC
ROUTER
TAP
FIBER NODE
PC
CMTS
DS2800
SET TOP
TV
www.deviserinstruments.com
DS2800 Spectrum Analyzer
Key Features:
• Fast spectrum analysis with 80 dB dynamic range
• QAM/Digital TV analysis
• Integrated DOCSIS 3.0 cable modem
• Ultra-fast QAM signal lock
• Gated measurements
• Equalizer, frequency response and group delay
• FCC Analog/Digital Proof-of-Performance automated tests
• Transport stream (TS)/MPEG analysis in PID with TR-101 290 MPEG
monitoring
• Persistence testing
• In-Service error vector spectrum (EVS) testing
• Simultaneous display of QAM and spectrum analysis
• Integrated return path sweep
• Upstream signal generator
• Wifi Analysis
• IP Test
www.deviserinstruments.com
2
DS2800 Spectrum Analyzer
Error Vector Spectrum (EVS) Analysis
Gated Measurement
The error vector spectrum analysis is new to handheld instruments.
With EVS, the user can quickly detect and identify interference from the
fast growing LTE network. This type of interference typically cannot be
seen with frequency domain measurements as the interference signal
is too weak.
The Gated measurement enables the engineer run in-service C/N,CSO,
CTB measurements.
Figure 4: Analog TV Gated Measurement
Figure 1: EVS with interference
Simultaneous display of Spectrum and QAM Analysis
The DS2800 displays QAM signal spectrum analysis andQAM
measurement results on one screen. This new feature empowers the
user to check the signal’s different characters at the same time, and
easily find the fault.
Figure 2: EVS without interference
Fast Spectrum Analysis Function
Figure 5: Simulaneous Display of Spectrum and QAM Analysis
The spectrum analyzer on the DS2800 has a frequency range of up to
2150 MHz, with a dynamic range of 80 dB.
Figure 3: Spectrum Analysis
www.deviserinstruments.com
www.deviserinstruments.com
3
DS2800 Spectrum Analyzer
Upstream Spectrum Persistence Technology
DVB-C Signal Analysis
The new spectrum persistence analysis enables in-service detection of
transient noise and impairments hiding beneath the upstream signal.
Traditionally, troubleshooting the upstream channels is done by finding
a free upstream spectrum. However, with the introduction of DOCSIS
3.0, the upstream channel is now extremely crowded, making it difficult
to distinguish the upstream signal from the interference signal. The
new persistence analysis facilitates finding impairments such as CPD
and impulse noise with a color coded spectrum display.
DS2800 supports ITU-T J.83 Annex A/B/C standards. The test
automatically provides power level, MER, BER, constellation
measurements.
Figure 9: DVB-C Measurement
Figure 6: Spectrum Analysis: Low Level Signal Covered by High Level Signal
Figure 10: Constellation Display
Figure 7: Persistence Shows Low Level Signal Covered by High Level Signal
Figure 11: BER and MER Statistical Analysis
Figure 8: Persistence Shows Low Level Signal Covered by High Level Signal
www.deviserinstruments.com
4
DS2800 Spectrum Analyzer
Equalizer, Frequency Response and Group Delay Analysis
In a cable TV network, the most common signal impairments come from
impendence mismatch and filters. Impendence mismatch can cause
serious micro-reflection, which can overlay the transmission signal. This
results in amplitude fluctuations or standing waves, which can affect
signal quality. The equalizer, frequency response and group delay
analysis are the best tools to troubleshoot these linear distortions.
Figure 15: TR 101 290 Monitoring
Cable Modem Measurement
Figure 12: Adaptive Equalizer
The DS2800 includes a DOCSIS 3.0 cable modem which supports 4
bonded upstream channels and 8 downstream channels. It is also
compatible with DOCSIS 1.x and 2.0. The measurement displays
statistics such as downstream signal level, modulation type, bandwidth,
symbol rate, MER, BER and upstream signal level, modulation type,
bandwidth, symbol rate, UCD (Upstream Channel Descriptor), standard.
User can change MAC address, choose DOCSIS mode, downstream
channel and UCD. Basic network test tools include: Ping, Traceroute,
PPPoE, FTP and Browser.
Figure 13: Group Delay
Figure 16: DOCSIS 3.0 Statistical Information Display
Figure 14: Frequency Response
www.deviserinstruments.com
www.deviserinstruments.com
5
DS2800 Spectrum Analyzer
Reverse Path Sweep and Upstream
Spectrum Verification
With DS1610 broadband network monitor system DS2800 can run
reverse path sweep. DS2800 can use these test results to draw the
frequency response curve. This curve describes fromDS2800 position
(Field) to DS1610 position (Headend) return path frequency response.
DS2800 use FSK function connection to DS1610 can look at you test
port upstream spectrum.
Auto Test
The auto test on the DS2800 runs through a pre-configured test with the
push of one button. The user can create test profiles that define a test
procedure with pass/fail limits. This simplifies test result interpretation
and ensures consistent testing. Even an inexperienced user can run
the test and verify that the installation is up to the same specification as
others. The results are then saved automatically.
Figure 19: Auto Test Project
Figure 17: Return Path Sweep
Upstream Signal Generator
Upstream signal generator can generate both sine wave and QAM
signals. The QAM signal has FEC coding, which supports both Annex A
and B. The USG is useful for pre-qualifying new installations and new
frequencies with an actual signal.
Asset and Test-Data Management Software
Deviser’s newly launched asset and data management system, SYNCOR
enhances work efficiency by allowing the user to manage test profiles,
sending work orders to the instrument and managing test results and
reports.
Figure 18: System Management
Figure 18: Upstream Signal Generator
Figure 19: Exported Test Report
www.deviserinstruments.com
6
DS2800 Spectrum Analyzer
Specifications
Forward Spectrum Analysis
Frequency Range
Frequency Stability
Frequency Span
Frequency Step
Resolution Bandwidth (-3dB)
Video Bandwidth
Display Scale and Range
Sweep Time
Input Level Range
Dynamic Range
Sensitivity
Attenuation
Accuracy of Measurements
Measurement Detector
Reference Level
Markers
4MHz ~ 1220MHz; option 4MHz ~ 2150MHz
±1x10-6 (0°C ~ 50°C)
0MHz ~ Full span
1 kHz
1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, 1MHz, 3MHz
30Hz, 100Hz, 300Hz, 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, 1MHz, 3MHz
1, 2, 5, 10, 20 dB/Div; 8 vertical divisions
20ms ~ 25s
-60dBmV ~ +60dBmV
80dB (30kHz RBW)
-60dBmV (300 kHz RBW, Pre-amplifier On)
0~30dB in 1dB Steps
<±1.0dB@+25±5ºC (typical value)
Positive Peak, Negative Peak, Sample, Average, RMS
-80dBmV ~ +70dBmV
2 vertical markers
Upstream Spectrum Analysis
Frequency Range
Frequency Span
Resolution Bandwidth (-3dB)
Video Bandwidth
Display Scale and Range
Sweep Time
Input Level Range
Attenuation
Pre-amplifier
Accuracy of Measurements
Measurement Detector
Markers
4~46MHz (DOCSIS); 4~68MHz (Euro DOCSIS 2.0); 4~88MHz (Euro DOCSIS 3.0); 4~120MHz (DOCSIS 3.1); 4~210MHz (DOCSIS 3.1)
42/64/84/116/206MHz, zero span
100kHz, 300kHz
30Hz, 100Hz, 300Hz, 1kHz, 3kHz, 10kHz, 30kHz, 100kHz, 300kHz, 1MHz, 3MHz
1, 2, 5, 10, 20 dB/Div
20ms ~ 25s
-60dBmV ~ +60dBmV
Automatic, 0~30dB
Manual, 18dB Gain
<±1.0dB@+25±5ºC (typical value)
Positive Peak, Negative Peak, Sample, Average
2 vertical markers
Persistence
0-7MHz
4-46MHz
4-68MHz
4-88MHz
4-120MHz
4-210MHz
100%POI minimum signal duration 2.5ms
100%POI minimum signal duration 3ms
100%POI minimum signal duration 4ms
100%POI minimum signal duration 5ms
100%POI minimum signal duration 6ms
100%POI minimum signal duration 10ms
Analog TV Measurement
Standards
Colour Standards
Frequency Steps
Level Measurement Range
Accuracy of Measurement
Level Resolution
Resolution Bandwidth
C/N
CTB/CSO
HUM Measurement
Depth of Modulation
Tilt
Pre-amplifier
Attenuator
B/G, I, D/K, L/L’, M/N
NTSC, PAL, SECAM
10kHz
-40dBm ~ +60dBmV
<±1.0dB @ +25±5°C (S/N>30dB)
0.1dB
300 kHz
>53dB
82dBµV~87dBµV 0dB Attenuation - Amplifier Off
Optimum Input Range
62dBµV~67dBµV 0dB Attenuation - Amplifier On
63dB with ±1.5dB Accuracy and 78 Channels
Maximum
70dB with ±4.0dB Accuracy and 78 Channels
1% ~ 20%; ±0.5% (1~5%); ±1.0% (5%~20%)
Range 40 to 95%, ±1.5%(C/N>40dB)
Up to 16 channels
Automatic, 18dB Gain
Automatic, 30dB
www.deviserinstruments.com
www.deviserinstruments.com
7
DS2800 Spectrum Analyzer
WiFi
Frequency
Support Standard
Security Mode
Encryption
Test Parameters
2.4G, 5G
802.11 a/b/g/n
WPA/WPA2/WPA-PSK/WPA2-PSK
WEP/AES/TKIP
SSID, Level, Channel
Digital TV Measurement
Frequency Range
Power Level Range
Level Resolution
Power Level Accuracy
Pre-amplifier
Attenuator
Modulation Type
Interleave Depth
Symbol Rate
SNR
MER
EVM
BER
Constellation
4 ~ 1220MHz
-30dBmV ~ +50dBmV
0.1dB
<±1.5dB (C/N>20dB) @+25±5°C
Automatic, 18dB Gain
Automatic, 30dB
16, 32, 64, 128, 256 QAM (J.83 Annex A and C); 64, 256 QAM (J.83 Annex B)
128×1~128×7(J.83 B); 12×17(J.83 A/C)
1.0MS/s ~ 7.0MS/s
>45dB; Accuracy:±2.0dB
>45dB; Accuracy:±2.0dB
<0.36%
1E-3 ~ 1E-9
16, 32, 64, 128, 256 QAM
Cable Modem Measurement
Support Standard
DS Demodulation
DS Frequency Range
DS Maximum Speed
DS Channel Bonding
DS Bandwidth
DS Input Signal Level
US Frequency Range
US Signal Bandwidth
US Output Signal Level
US Channel Bonding
US Maximum Speed
DOCSIS 1.1, 2.0, 3.0; EuroDOCSIS 1.0, 1.1, 2.0, 3.0
64, 256QAM
>91MHz (5~65MHz US); >100MHz (5~85MHz EU)
Up to 304Mbps (6MHz); And 400Mbps (8MHz)
Up to 8 channels
6MHz / 8MHz
-15dBmV to +15dBmV
5 ~ 42MHz; 5 ~ 65MHz; 5 ~ 85MHz
TDMA: 200/400/800/1600/3200/6400kHz; S-CDMA: 1600/3200/6400kHz
QAM level range: +17 to +58dBmV;QPSK level range: +17 to +61dBmV
Up to 4 channels
120Mbps (4 channels bonding)
Upstream Signal Generator
Signal Modulations
FEC
Symbol Rates
MER
BER
Frequency Range
Frequency Adjustable Steps
Phase Noise
Frequency Accuracy
Settling Time
Supported Level
Level Accuracy
Level Adjustable Step
CW, QPSK, QAM16, 64, 256, Annex A/B
RS (204,188) J.83 A; RS (128,122) J83B
1~7 MS/s
>40dB; Accuracy ±2.0dB
<1E-9
5~120MHz
10kHz
85dBc@10kHz; 105dBc@100kHz (CW@50MHz)
2ppm
2ms
0~60dBmV
±1.5dB(CW); ±2.0dB(QAM)
0.1dB
www.deviserinstruments.com
8
DS2800 Spectrum Analyzer
Reverse Path Sweep
FSK Tx Frequency
FSK Tx Amplitude
FSK Rx Frequency
FSK Rx Sensitivity
Pilot Frequency
Pilot Frequency Amplitude
Tx Test Signal Amplitude
Tx Test Signal Frequency
Tx Test Frequency Point
Headend Support DS2800 Number
5~65MHz
70 dBμV ~ 110 dBμV
42~120MHz
20dBμV
5~65MHz
70 dBμV ~ 110 dBμV
60dBμV~120dBμV
5~65MHz
1~16 Frequency Points
DS1610 Max Support 4 DS2800 Units
DS1615
Size
FSK Tx Frequency
FSK Tx Level
Modulation type
Baud Rate
1U Standard Rack
42MHz~120MHz
85dBμV~110dBμV
FSK
38.4kbps
Other
RF Input
USB
Ethernet
Display
AC/DC Adapter
Battery
Charge Time
Working Time
Dimension (W×H×L)
Weight
Work Temperature
Storage Temperature
75Ω F-Type connector
USB 1.1
RJ45, 10/100T Ethernet
7 inches TFT LCD 800×480 pixels
AC 100 ~ 240 V/50 ~ 60Hz DC 12V / 5A
Li-ion, 7.4 V/10Ah
Around 4 hours
8 Hours
245mm×155mm×60mm
Around 2.2kg
-10 ~ +50°C
-20 ~ +70°C
Deviser Instruments, Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131 ©2014 Deviser Instruments Incorporated. All rights reserved. Specifications subject to change without notice. All product and company
names are trademarks of their respective corporations. Deviser Instruments manufacturing facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Deviser Instruments. DS2800 140921
www.deviserinstruments.com
www.deviserinstruments.com
9
Broadband
DS8831H Rack Mount
Spectrum Analyzer Series
Key Benefits
•Compatible with Kingstone (DS1610) CATV monitoring system
•Rackmount, high performance spectrum analyzer with up to
1 GHz range
•Enables user to quickly repair and troubleshoot problems
by identifying impairments and detecting interference
•Remotely configure and perform tests from anywhere,
anytime through Ethernet or SCPI
•Convenient data storage data and instrument upgrade
through USB
•Validate components with tracking generator
CATV Analysis:
•Level, HUM, Depth of Modulation, C/N, CSO/CTB,
Cross Modulation, In-Channel Frequency Response
Differential Phase/Gain, Chrominance to Luminance Delay
Inequality, etc.
DVB-C Analysis:
•Constellation, Power Level, MER, Pre & Post BER, EVM, EVS,
MER/BER Statistical Analysis, etc.
Spectrum Analysis:
•Real-time Sweep, Fine adjustable RBW/VBW, High Accuracy, etc.
The DS8831H is the versatile rack mount version of our QAM/Spectrum analyzer series. The DS8831H provides identical performance
characteristics as our DS8831Q portable version, at a more competitive price. It is ideal for remote head end or hub applications where access is
impractical.
www.deviserinstruments.com
DS8831H Spectrum Analyzer Series
Specifications
Model
Frequency
Frequency Range
Frequency Stability
Aging
Frequency Resolution
Frequency Span range
Sweep Time
Accuracy
Trigger Types
RBW
Accuracy
Selectivity
VBW
Phase Noise Stability
Amplitude
Measurement Range
Attenuator
Internal Amplifier
Frequency Range
Gain
Max Safe Input
Gain Compression
DS8831H
1 MHz to 1GHz
+/- 2 ppm
10 Hz
0 Hz (0 span), 1 kHz to 1000 MHz
1 mS to 500 sec (span > 0 Hz)
20 uS to 500 sec (span = 0 Hz)
< +/- 1%
Free run, Single, Video, TV channel
1 kHz to 3 MHz (1-3-10 Sequence)
< +/- 15%
< 5:1 (60 dB/3 dB Bandwidth Ratio)
< -120 dBc/Hz @ 100 kHz offset from CW signal
< -95 dBc/Hz @ 10 kHz offset from CW signal
Displayed Average Noise Level to Max.
Safe Input Level
1 MHz to 1000 MHz
20 dB (typical)
+68 dBmV (peak power/input attenuation >15 dB) 100 V DC
0.5 dB@39 dBmV (attenuator= 0 dB and preamp off), 0.5 dB@ 19 dBmV (attenuator= 0 db and preamp on)
Displayed Average Noise level (Input
Terminated, 0 dB Attenuator, 30 kHz RBW,
100 Hz VBW, Sample Det)
Distortion
< -95 dBmV/Hz with preamp Off (Typical)
< -105 dBmV/Hz with preamp On (Typical)
2nd order Spurious Distortions
3rd order Intermodulation Distortions
Residual Responses (Input Terminated and
0 dB Attenuator)
Level Accuracy
Resolution Bandwidth Tolerance
Input Attenuator Tolerance
Response Flatness
Analog CATV Measurements
< -68 dBc for +29 dBmV signal at input mixer and preamp OFF
<-68 dBc for +29 dBmV signal at input mixer with 1 Mhz separation and preamp OFF
Channel Selection
Channel Plans
TV Channel Amplitude Range
Channels Scans
Multi-Channel View
Single-Channel Mode
Tuning Range
TV Visual Frequency
Accuracy
Resolution
Visual/Aural Delta
Accuracy
Resolution
Amplitude
FM Deviation Range
Hum/Low Frequency Distortions
Modes
Range
Accuracy
Depth of Modulation
Frequency and Channel
NTSC, PAL, and Custom Plans
-40 dBmV to +65 dBmV, ±1.0 dB @ 20 °C, for S/N > 30 dB
50 Analog channels, approx. 6 seconds, 50 Digital channels, approx. 15 seconds
Selectable, up to 8 channels
With Spectrum Display
5 MHz to 1000 Mhz
Amplitude Modulation Range
Resolution
Accuracy
Signal Type
< -55 dBmV, 1 MHz to 1000 MHz
< +/- 1 dB @ 20 °C
< ± 0.1 dB
< ± 0.3 dB (Typical)
± 1.0 dB. 1 MHz to 1000 MHz
Carrier Frequency ± 2ppm
1 Hz
± 200 Hz
1 Hz
± 1 dB, S/N > 30 dB
100 kHz
CW or Modulated
1% to 20%
±0.5% from 1 to 5%, ±1% from 5 to 20%
40% to 90%
0.1%
±1.5% (CCN > 40dB)
VITS line with white reference
www.deviserinstruments.com
2
DS8831H Spectrum Analyzer Series
Carrier to Composite Noise
Optimum Input Level
Maximum CCN Measurement
Resolution
CSO/CTB
Optimum Input Level
Maximum CSO/CTB Measurement
Resolution
Cross Modulation
Range
Resolution
Accuracy
In-Channel Frequency Response
Test Signal Type
Range
Resolution
Accuracy
Differential Phase Accuracy
Differential Gain Accuracy
Chrominance to Luminance
Delay Accuracy
QAM/DVB-C
Modulation Types
Interleaving
Constellation Display
Adaptive Equalizer Display
Digital Channel Power
Amplitude Range
Resolution
Accuracy
Measurement Bandwidth
MER
Range
Accuracy
BER
Error Vector Magnitude
Statistical Mode
Power Specifications
Input Range
Frequency
General
RF Input
Input VSWR
Operating Temperature
Storage Temperature
Dimensions
Weight
USB Port
Ethernet
COM
+5 dBmV
> 55 dB ±2 dB, > 60 dB ± 3 dB
0.1 dB
+5 dBmV
> 63 dBc with ± 1.5 dB (78 channels)
> 70 dBc with ± 4.0 dB (78 Channels)
0.01 dB
- 45 dB to -65 dB
0.1 dB
± 2.0 dB for Xmod < 55 dB, CCN > 40 dBc± 4.5 dB for Xmod < 60 dB, CCN > 40 dBc
Multiburst, or GCR VITS Signal
± 10 dB
0.1 dB
±0.25 dB
±2%
±3°
±40 ns
16/32/64/128/256 QAM, QPSK (ITU-T J.83 Annex A/B/C) QPSK (ITU-T J.83 Annex A/B/C)
Up to128 × 4 in Annex B, 12 × 17 in Annex A/C
QPSK, 16/32/64/128/256 QAM with Zoom capability
8 FFE taps, 24 DFE taps
-30 dBmV to +60 dBmV
0.01 dB
±1.0 dB @ 20 ℃ ±5 ℃, (C/N > 20 dB) Typical
200 kHz to 999 MHz
>43 dB
±0.5 dB (22 to 30 dB); ±1.0 dB (30 to 35 dB); ±1.8 dB (35 to 43dB)
1.0 x 10E-9 to 2 x 10E-3
< 0.65%
1 to 4320 Minutes
90 to 240 VAC
47 to 440Hz
BNC or F-Type connector (75 ohm), N-Type (50 ohm)
> 14dB, 10-1000 MHz (w/10dB input attenuation)
0°C to +50°C
-10°C to +50°C
19” x 1.25” (1RU) x 15.75”
3 kg
USB 1.1
10/100 MB/s
RS-232 Serial Port
©2014 Deviser Instruments Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131. All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of their respective corporations. Deviser Instruments manufacturing facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Deviser Instruments. DS8831H Rack Mount Rev.1 140916
www.deviserinstruments.com
3
Broadband
DS8831Q & DS8853Q
Spectrum Analyzer Series
Key Benefits
•Portable, high performance spectrum analyzer with up to
3 GHz range
•Enables user to quickly repair and troubleshoot problems by
identifying impairments
•Detect interference from sources such as microwaves, phones,
satellite and wifi to maintain HFC network at optimal performance
•Remotely configure and perform tests from anywhere,
anytime through Ethernet or SCPI
•Verify terrestrial digital tv (air) channels with 8VSB-ATSC
modulation
•One-button automated, analog and digital FCC
proof-of-performance test
•Convenient data storage data and instrument upgrade
through USB
•Validate components with tracking generator
Key Features
CATV Analysis:
The DS8853Q/8831Q is a versatile portable QAM/Spectrum analyzer
series, featuring extensive analog and digital RF signal analysis
capabilities, necessary on today’s modern HFC networks. With the
migration towards fully digital CATV plants and the constant challenges
of new services potentially interfering with HFC networks, the modern
CATV maintenance technician requires easy-to-use, high performance
test equipment allowing him to keep the network running at optimal
performance.
•Level, HUM, Depth of Modulation, C/N, CSO/CTB,
Cross Modulation, In-Channel Frequency Response
Differential Phase/Gain, Chrominance to Luminance Delay
Inequality, etc.
DVB-C Analysis:
•Constellation, Power Level, MER, Pre & Post BER, EVM, EVS,
MER/BER Statistical Analysis, etc.
Spectrum Analysis:
•Real-time Sweep, Fine adjustable RBW/VBW, High Accuracy, etc.
Model
The DS8853Q/8831Q series provides a familiar, intuitive user interface
allowing the technician to actually troubleshoot and run tests, rather than
figuring out how to run the instrument.
DS8853Q 3G
DS8831Q
Spectrum Analysis
●
●
Workbench-PC Management Software
●
●
CATV
●
●
DVB-C
●
●
ASI Output
●
✖
8VSB
❍
✖
Tracking Generator-3 GHz
❍
✖
Tracking Generator-1 GHz
✖
❍
30/100/300 Hz RBW
❍
❍
Spectrum Monitoring
❍
❍
● standard configuration ✖ not available ❍ optional
www.deviserinstruments.com
www.deviserinstruments.com
DS8831Q/DS8853Q Spectrum Analyzer Series
DVB-C Analysis
CATV Analysis
Spectrum Analysis
www.deviserinstruments.com
www.deviserinstruments.com
2
DS8831Q/DS8853Q Spectrum Analyzer Series
Work Bench - PC Management Software
• The Workbench is a data management application used to establish
network communication between a PC or laptop computer and with
the DS8853Q/8831Q series. Easily manage all data, tests applications
and test data results.
• It performs the following tasks:
- Communication and remote control of the
DS8853Q/8831Q series via Ethernet
- Create, edit, upload and download Channel Plan
- Download and review the screen captures
-Transfer and save
www.deviserinstruments.com
www.deviserinstruments.com
3
DS8831Q/DS8853Q Spectrum Analyzer Series
Specifications
Model
Frequency
Frequency Range
Frequency Stability
Frequency Resolution
Counter Resolution
Sweep range
Sweep range
RBW
VBW
Phase Noise Stability
Amplitude
Measurement Range
Accuracy
Resolution
Amplifier Frequency Range
Range
Amplifier Gain
Amplifier Noise Figure
Max Safe Input
Display
Logarithm Scale
Linear Scale
Vertical Scale Unit of Measure
Marker Readout Resolution
Trace Detector
Reference Level
Resolution Bandwidth Tolerance
Input Attenuator Tolerance
Amplitude Flatness
Amplitude Range
HUM/LFI
DS8831Q
DS8853Q
1 MHz to 1GHz
+/- 2 ppm
10 Hz
1 Hz
0 Hz (0 span), 1 kHz, 1000 MHz
20 ms to 500 sec. (span > 0 Hz), 20 us to 500 sec. (span = 0 span)
1 kHz to 3 MHz (1-3 Step)
30 Hz to 1 MHz (1-3 Step)
500 kHz to 3 GHz
+/- 2 ppm
1 Hz
1Hz
0 Hz (0 span), 1kHz, 3000 MHz
20 ms to 250 sec. (span > 0 Hz), 20 us to 500 sec. (span = 0 span)
1 kHz to 3 MHz (1-3 Step)
30 Hz to 1 MHz (1-3 Step)
< -120 dBc/Hz @ 100 kHz offset from CW signal
< -95 dBc/Hz @ 10 kHz offset from CW signal
< -120 dBc/Hz @ 100 kHz offset from CW signal
< -100 dBc/Hz @ 10 kHz offset from CW signa
Displayed Average Noise Level to Maximum Safe Input Level
±1 dB @ +25°C ±5 °C
±1 dB @ +25°C ±5°C
0.01 dB
±1 dB @ +25°C ±5 °C
0 dB to 55 dB, 5 dB Step
0 dB to 50 dB, 5 dB Step
1 MHz to 1000 MHz
500 kHz to 3000 MHz
20 dB
15 dB
4 dB
4 dB
+68 dBmV, 100 V DC
+78 dBmV, 100 V DC
0.1 to 1 dB/div in 0.1 dB step 1 to 40 dB/div in 1 dB step
10 divisions
dBm, dBmV, dBμV, mV
0.03 dB for log scale; 0.03% of ref level for linear scale
Normal, Average, Sample, Positive-Peak, Negative-Peak
-98 dBmV to +29 dBmV
< ±0.1 dB
< ±0.3 dB (typical)
±1.0 dB
40 dBmV to +65 dBmV, ±1.0 dB @ +25 ℃ , ±5 ℃ (S/N > 30 dB)
Range
Accuracy
Depth of Modulation
1% to 20%
±0.5% from 1% to 5%, ±1% from 5% to 20%
Range
Resolution
Accuracy
CC/N
Optimum Input Level
Maximum
Resolution
CTB/CSO
Optimum Input Level
Maximum Range
Resolution
Range
Accuracy
Resolution
In Chn. Freq Resp
Range
Accuracy
Resolution
Differential Phase Accuracy
Differential Gain Accuracy
Chrominance to Luminance
Delay Accuracy
40% to 95%
0.1%
±1.5% (C/N > 40 dB)
32 dBmV to 37 dBmV 0 dB Attenuation, Amplifier Off, 12 dBmV to 17 dBmV 0 dB Attenuation, Amplifier On
60 dB with ±1 dB Accuracy; 65 dB with ±3 dB Accuracy
0.1 dB
22 dBmV to 27 dBmV, 0 dB Attenuation w/ Amplifier Off, 2 dBmV to 7 dBmV, 0 dB Attenuation w/ Amplifier On
63 dB ±1.5 dB Accuracy (78 channels), 70 dB ±4.0 dB Accuracy (78 channels)
0.1 dB
-45 dB to -65 dB
± 2.0 dB for Cross Modulation @ < 55 dB, CCN > 40 dB, ± 4.5 dB for Cross Modulation @ < 60 dB, CCN > 40 dB
0.1 dB
±12 dB
±0.2 dB
0.1 dB
±2%
±3 °
±40 ns
www.deviserinstruments.com
www.deviserinstruments.com
4
DS8831Q/DS8853Q Spectrum Analyzer Series
Model
QAM/DVB-C
Modulation Types
Interleaving
Constellation Display
Adaptive Equalizer Display
Digital Chn. Power
Amplitude Range
Resolution
Accuracy
Measurement Bandwidth
MER
Range
Accuracy
BER
Error Vector Magnitude
Statistical Mode
Symbol Rate
Power Supply
Battery Type
External AC Adapter
Charge Time
Operational Time
General
Operating Temperature
Storage Temperature
Dimension (W×H×L)
Weight (With Battery)
Display
Display Resolution
DS8831Q
DS8853Q
16/32/64/128/256 QAM, QPSK (ITU-T J.83 Annex A/B/C)
Up to128 × 4 in Annex B, 12 × 17 in Annex A/C
QPSK, 16/32/64/128/256 QAM with Zoom capability
8 FFE taps, 24 DFE taps
-30 dBmV to +60 dBmV
0.1 dB
±1.0 dB @ (25 ℃ ±5 ℃, C/N > 20 dB) Typical
200 kHz to 999 MHz
>43 dB
±0.5 dB (22 to 30 dB); ±1.0 dB (30 to 35 dB); ±1.8 dB (35 to 43dB)
2 × 10E-3 to 1 × 10E-12
< 0.65%
1 to 4320 Minutes
1 to 7 Ms/Sec
14.8 V / 6 Ah Rechargeable Lithium-Ion
19 VDC / 3.42 A
14.8 V / 8 Ah Rechargeable Lithium-Ion
5 Hours
6 Hours
>3 Hours; >2.5 Hours (Including Optional Tracking Generator)
360 mm ×180 mm × 350 mm
9 kg
16 cm (6.4 inches) TFT Color LCD
0 to 50 °C (32 to 122 °F)
-20 to +55 °C (-4 to 131 °F)
640 X 480 Pixels
360 mm ×180 mm × 360 mm
10 kg
19 cm (7.5 inches) TFT Color LCD
©2014 Deviser Instruments Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131. All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of their respective corporations. Deviser Instruments manufacturing facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Deviser Instruments. DS8831Q/DS853Q 140921
www.deviserinstruments.com
www.deviserinstruments.com
5
Satellite & Terrestrial
S7000
TV & Satellite Analyzer
Key Benefits
• All standards in one: QAM(J.83A/B/C), 8VSB, DVB-T/H/T2,
DVB-S/S2
• Digital/Analog TV and Satellite TV analysis
• MPEG2 Transport stream analyzer and monitoring via
TS-ASI input &RF input
• Fast spectrum analysis with 5 ~ 2150 MHz frequency span
• DSP Technology to support different Video decoding: MPEG• MPEG-4 and H.264 for 1080i, 720p and 576i, support PAL/
NTSC/SECAM color system
• Support SD&HD Video format
• DVB-CI module (Conditional Access) for encrypted channels
• TS-ASI input and output
• TS record and TS replay
• IPTV analysis option
• GPS option
• HDMI, LAN and USB interface
• Easy to use
• High resolution 7" TFT LCD with bright display for indoors
and outdoors use
• W245×H194×L105, light weight.
• Working time > 5 hours (battery)
Analog TV, FM
DVB-C
DVB-T
DVB-S/S2
DVB-T2
DTMB
CI Module
ASI Output/Input
TS Analyzer Module
IPTV
S7000
■
■
■
■
❏
❏
❏
■
❏
❏
S7000L
■
■
■
■
✖
✖
✖
✖
❏
❏
www.deviserinstruments.com
S7000 TV & Satellite Analyzer
TV Monitoring
S7000 provides analog and digital TV monitoring. It supports video
decoding standards with DSP Technology: MPEG-2, MPEG-4 and H.264
for 1080i, 720p and 576i, and PAL/NTSC/SECAM color
system. It also supports SD&HD video format and CAM module
(Conditional Access) for encrypted channels.
MPEG4 HD for 1080i Decode
Simple and user friendly GUI
The S7000 has a familiar windows style main menu, shortening the
learning curve for even the novice users. It is very easy to operate the
analyzer with navigation keyboard, even without the manual.
TV Main Menu
Satellite Main Menu
TV Signal Sweep
Satellite Signal Sweep
Spectrum Measurement
The S7000 has a comprehensive spectrum analysis function. The sweep
span covers TV& Broadcasting signal(5-1050 MHz) and Satellite IF signal
(950-2150MHz).
DVB-S/S2 Signal Analysis
S7000 supports DVB-S/S2 standard and provides Power level, MER, BER, constellation measurement.
DVB-S2 Constellation
DVB-S Constellation
DVB-S/S2 Signal Measurement
Display Max. 12 Transponder
Signals' quality to Align DishAntenna
DVB-T signal measurement
DVB-T constellation
DVB-T Echo pattern for locating SFN
interference
DVB-T MER versus carriers
DVB-T2 signal measurement
DVB-T2 constellation
DVB-T2 Echo pattern for locating SFN
interference
DVB-T/T2 Signal Analysis
www.deviserinstruments.com
2
S7000 TV & Satellite Analyzer
DVB-C Signal Analysis
S7000 supports J83 A/B/C/D standard and provides Power level, MER, BER, constellation measurement. The EVS tool is helpful to find the interference
signal under the QAM mask.
QAM signal quality measurement
QAM constellation measurement
8VSB signal analysis
MPEG4 HD for 1080i Decode
Remote Feeding and Control Signal Setting
S7000 provides feeding power 5/13/15/18/24V and Max. power is 5W.
The 22 kHz control signals is compatible with DiSEqC 1.2 and SaTCR.
TS Analysis and Monitor
S7000 is a handheld TS analyzer. It provides TR101 290 3 level monitoring and list PSI/SI and program PID of transport stream. S7000 also lists
the details of all programs running in a TV network or a transponder. The TS is from RF signal or TS-ASI input. S7000 has 8GB hard disk to save TS file
and can replay and analysis TS file.
Programs Decode Monitoring and List
Basic Information Of TS
PCR Interval and PCR Accuracy Monitoring
PSI/SI Tree List
EPG for a Transponder or TV System
TR101 290 Three Level Monitoring
TR101 290 Monitoring Error Event List
Program Information
PID List
PID Capture
Limit Settings for TR101 290 Monitoring
www.deviserinstruments.com
3
S7000 TV & Satellite Analyzer
Specifications
Spectrum Analysis
Frequency Range
5 MHz ~ 1050 MHz (TV), 950 MHz ~ 2150 MHz (Satellite)
Frequency Span
0 ~ 1045MHz(TV), full/600/300/200/100/50/20/10MHz (Satellite)
Frequency Step
10 kHz (TV), 1 MHz (Satellite)
RBW
3 MHz (TV) 1 MHz, 3 MHz Auto Select (Satellite)
Level Range
10 dBμV ~ 120 dBμV (TV) 30 dBμV ~ 120 dBμV (Satellite)
Level Accuracy
±1.5dB
Detection Types
Peak, sample, AVG (TV)
Reference Level
30 dBμV ~ 120 dBμV
Markers
2 (TV) 1 (Satellite)
Analogue TV Measurement
Standards
B/G, I, D/K, L/L´, M/N
Colour Standards
PAL, SECAM, NTSC
Frequency Step
10 kHz
Hum Measurement
1% ~ 15%
C/N
> 50dB
Level Measurement Range
30 dBμV ~ 120 dBμV
Accuracy Of Measurements
±1.5dB
Level Resolution
0.1 dB
Digital CATV Measurement
Modulation Type
16/32/64/128/256 QAM ITU-T J.83 ANNEX A/B/C
Symbol Rate
4.0 MS/s ~ 7.0 MS/s
Power Level Range
30 dBμV ~ 110 dBμV
Level Resolution
0.1 dB
Power Level Accuarcy
±2.0 dB(C/N > 20 dB)
MER Measurement
~40 dB
MER Accuracy
±2.0 dB
BER
1E-3 ~ 1E-9
Constellation
√
DVB-T/H Measurement
Modulation Type
QPSK, 16 QAM, 64 QAM
Bandwidth
6MHz, 7 MHz, 8 MHz
Power Level Range
25 dBμV ~ 110 dBμV
Level Resolution
0.1 dB
Power Level Accuarcy
±2.0dB (C/N >20dB)
MER Measurement
> 30 dB
MER Accuracy
±2.0 dB
CBER/VBER
√
Constellation
√
MER Versus Carriers
√
Echo Pattern
√
www.deviserinstruments.com
4
S7000 TV & Satellite Analyzer
DVB-T2 Measurement
Modulation Type
QPSK, 16 QAM, 64 QAM, 256QAM
Bandwidth
5MHz ,6MHz, 7MHz, 8MHz
Power Level Range
25 dBμV ~ 110dBμV
Level Resolution
0.1dB
Power Level Accuarcy
±2.0 dB(C/N >20 dB)
MER Measurement
>32 dB
MER Accuracy
±2.0 dB
CBER/LBER
√
Constellation
√
Echo Pattern
√
ATSC Measurement
Modulation Type
8 VSB
Power Level Range
25 dBμV ~ 110 dBμV
Level Resolution
0.1 dB
Power Level Accuarcy
±2.0 dB(C/N >20 dB)
MER Measurement
~40 dB
MER Accuracy
±2.0 dB
BER
√
Constellation
√
DTMB Measurement
Carriers
C=1, 3780
Power Level Range
25 dBμV ~ 110 dBμV
Level Resolution
0.1 dB
Power Level Accuarcy
±2.0 dB (C/N >20dB)
MER Measurement
>30 dB
MER Accuracy
±2.0 dB
BER
√
Constellation
√
Echo Pattern
√
DVB-S/S2 Measurement
Modulation Type
QPSK, 8PSK
Symbol Rate
2 - 45 MS/s (DVB-S). 1 - 45 MS/s (QPSK DVB-S2). - 45 MS/s (8PSK DVB-S2)
Power Level Range
40 - 110 dBμV
Level Resolution
0.1 dB
Power Level Accuarcy
±2.0 dB (C/N>20dB)
MER Measurement
> 25 dB
MER Accuracy
±2.0 dB
BER
DVB-S (CBER/VBER), DVB-S2 (CBER/LBER)
Constellation
√
Video/Audio Decoder
Video
MPEG 2/4, H.264
Video Resolution
1080i, 720p and 576i
Audio
MPEG1/2, AAC
CAM Module
EN50221 (DVB-CI) PCMCIA interface
TS-ASI Input And Output
√
TS Record
√
www.deviserinstruments.com
5
S7000 TV & Satellite Analyzer
TS Analyzer
Stander Interface
En 50083-9(DVB SPI, ASI)
DVB-ASI Interface
75 Ω BNC
DVB-ASI Clock
270 MHz
DVB-ASI Max Data Rate
0 to 72 Mbps
DVB-ASI Output Signal Level
1.0 Vp-p nominal
DVB-ASI Return Response
> 15dB
DVB-ASI Input Level
800 mV +/- 10%
Realtime Decoder
3 Level Monitoring
Display the real television pictures (through CA system). Including program numbers, program names, provider information, video & audio PIDs
TRT101 290 3 level monitor the transmission stream documents which meets the DVB standard, and save the error record to database for
future checking (excluding STD-BUFFER analysis).
Base Information
Count the PIDs percent according to the type of the streams. Videos, Audios, PSI/SI, Null Packages
PID List
Display all the PIDs in current stream
Program Information
The detail infos about a program if it isn’t be encrypted. The video resolutions and audio compress rate.
PCR Monitor
Calculate PCR interval and PCR accuracy
PSI/SI List
Display the PSI/SI infos by tree view. Including PAT,PMT,CAT,(NIT,SDT,RST,TDT,EIT options)
Program Info
EPG
PID Capture
Capture a specified PID by it’s type: Video, Audio, PSI(PAT, PM, NIT, TDT, RST, SDT, EIT) etc. And display the data in HEX format
Transport Stream Record and Replay
<2 GB (udisk) for TS record and TS Replay
Interface
RF Input
75 Ω F
HDMI Output
1
USB
1 USB 2.0
LAN
1 10/100 M
DVB-CI
1 PCMCIA
TS-ASI Input/Output
2 75 Ω BNC
DC Supply Input
12 V / 5 A
GPS Input
USB
General
Display
7 inches TFT LCD 800 × 480 pixels
AC/DC Adapter
AC 100 - 240 V/50-60 Hz DC 12 V/5 A
Battery
Li-ion, 7.4 V/13 Ah
Charge Time
Around 5 Hours
Working Time
>5 Hours
Remote Feeding
5/13/15/18/24 V, Max. 5 W
22 kHz Control Signals
DiSEqC 1.2 and SaTCR
Dimension (W×H×L)
245 mm × 194 mm × 105mm
Weight
Around 2.8 kg
Working Temperature
-10 ~ +50 ℃
Storage Temperature
-20 ~ +70 ℃
©2014 Deviser Instruments Incorporated. 780 Montague Expressway, Suite 606, San Jose, CA 95131 . All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of their