Multifunctional electrical installation tester MI 3155 EurotestXD

NEW
Multifunctional electrical installation tester
MI 3155 EurotestXD
Electrical Installation Safety
MI 3155 EurotestXD is the newest
flagship of Metrel’s most advanced
line of multi-functional measuring
instruments and is designed
specifically for testing in industry.
What differentiates this instrument
from the rest is its ergonomic design
and an intuitive user interface,
encompassing a memory organizer
and fully programmable AUTO
SEQUENCEs, managed through a large
colour touch screen display. It is fully
compliant with functionality standards
(e.g. IEC/EN 61557) and other reference
standards for testing (e.g. IEC/EN/
HD 60364-4-41,...) as is required for
any instrument that performs TRMS
current measurements, RCD tests,
line and loop impedance tests with
3 (and 4) wires and earth resistance
measurements. Besides those, the
instrument supports a wide range
of tests and measuring functions,
including on-line voltage monitoring,
phase sequence testing, varistor
testing, PI/DAR calculation, luminance
measurement, discharge time testing,
ISFL measurements, IMD tests as well
as functional and visual inspections.
MEASURING FUNCTIONS
•Live Transformer’s Impedance
Measurement with Four Wire Test;
•Hi-precision Short Circuit Current evaluation
with Calculated Hot factor;
•3-wire test of PE (RPE function) without
extension lead conductor;
•Autotest insulation function between L-N,
N-PE and L-PE (R ISO ALL function);
•4 wire continuity test;
•Insulation resistance with DC voltage from
50 V to 2500 V and PI, DAR calculation;
•Varistor test;
•Continuity of PE conductors with 200 mA DC
test current with polarity change;
•Continuity of PE conductors with 7 mA test
current without RCD tripping;
•2-wire and 3-wire loop impedance (L-PE)
measurement with Trip Lock RCD function;
•Touch voltage / Contact voltage
measurement with external P/S probe.
•2-wire and 3-wire line impedance (L-L, L-N)
measurement;
•1-phase / 3-phase TRMS voltage and
frequency measurements;
•Line, loop and RCD measurements at
frequency range 16 ... 400 Hz;
•Phase sequence;
•Power and THD measurement (up to the 12th
harmonic);
•RCD testing (general and selective, type AC,
www.metrel.si
A, F, B, B+, MI RCD, EV RCD, PRCD, PRCD-K,
PRCD-S);
•Earth resistance (3-wire and 2-clamps
method);
•Specific earth resistance with Ro-adapter
(option);
•TRMS leakage and load currents (option);
•First fault leakage current (ISFL);
•Testing of Insulation Monitoring Devices
(IMDs);
•Machine mode support with time discharge;
•Illumination (option);
•High resolution Loop impendance (mΩ)
(option);
•EVSE (Electrical Vehicle Supply Equipment)
support (option);
•Determining location of cables (option);
•QR and/or barcode scanner support (option).
KEY FEATURES
•Programmable AUTO SEQUENCEs.
•Predefined profile dependent
AUTO SEQUENCEs.
•Predefined Automatic tests:
Auto TT (U, Zln, Zs, Uc);
Auto TN/RCD (U, Zln, Zs, Rpe);
Auto TN (U, Zln, Zlpe, Rpe);
Auto IT (U, Zln, Isc, Isfl, IMD).
•Functional inspections.
•Visual inspections.
•Custom inspections (visual and functional)
which may be incorporated into AUTO
SEQUENCEs.
•EVSE AUTO SEQUENCEs and
function inspections;
•Machine functional and visual
inspections;
•Built-in help screens for
referencing on site.
•Built-in fuse tables for automatic
evaluation of the line / loop
impedance result.
•Monitoring of all 3 voltages in
real-time.
•Automatic polarity reversal on
continuity test.
•Automated RCD testing procedure
(RCD AUTO).
•Automated Impedance testing
procedure (Z AUTO).
•Measurement filtering according
to the selected area group.
•Built-in charger and rechargeable
batteries as standard accessory.
•BT communication with PC,
Android tablets and smart phones
via built-in BT.
•PC SW Metrel ES Manager
(structure and report creation, data
upload/download).
•Optional aMESM Android APP
(structure and report creation, data
upload/download).
TECHNICAL SPECIFICATION
Function
CONTINUITY
INSULATION RESISTANCE
RCD
IMPEDANCE
Measuring range
Resolution
Accuracy
Test Current 7 mA 2-wire
0.00 Ω ... 19.99 Ω
20.0 Ω ... 1999 Ω
0.1 Ω
1Ω
±(5 % of r. + 3 digits)
Test Current 200 mA 2-wire,
4-wire
0.00 Ω ... 19.99 Ω
20.0 Ω ... 199.9 Ω
200.0 Ω ... 1999 Ω
0.01 Ω
0.1 Ω
1Ω
±(3 % of r. + 3 digits)
±(5 % of r.)
±(5 % of r.)
R iso, R iso all 1
Test Voltage 50/100/250 V
0.00 MΩ ... 19.99 MΩ
20.0 MΩ ... 99.9 MΩ
100.0 MΩ ... 199.9 MΩ
0.01 MΩ
0.1 MΩ
0.1 MΩ
±(5 % of r. + 3 digits)
±(10 % of r.)
±(20 % of r.)
R iso, R iso all 1
Test Voltage 500/1000 V
0.00 MΩ ... 19.99 MΩ
20.0 MΩ ... 199.9 MΩ
200 MΩ ... 999 MΩ
0.01 MΩ
0.1 MΩ
1 MΩ
±(5 % of r. + 3 digits)
±(5 % of r.)
±(10 % of r.)
R iso, R iso all 1
Test Voltage 2500 V
0.00 MΩ ... 19.99 MΩ
20.0 MΩ ... 199.9 MΩ
200 MΩ ... 999 MΩ
1.00 GΩ ... 19.99 GΩ
0.01 MΩ
0.1 MΩ
1 MΩ
0.01 GΩ
±(5 % of r. + 3 digits)
±(5 % of r.)
±(10 % of r.)
±(10 % of r.)
DAR, PI
0.01 ... 9.99
10.0 ... 100.0
0.01
0.1
±(5 % of r. + 2 digits)
±(5 % of r.)
Varistor test AC, DC 2
0 V … 1000 V (DC)
0 V … 625 V (AC)
1V
±(3 % of r. + 3 digits)
RCD Uc
0.00 V ... 19.99 V
20.0 V ... 99.9 V
0.1 V
(-0 %/+15 %) of r. ± 10 digits
(-0 %/+15 %) of r.
RCD (t),
0.00 ms ... 40.0 ms
0.0 ms ... max. time
0.1 ms
±1 ms
±3 ms
RCD I Ramp
0.2xI∆N ... 1.1xI∆N (AC, MI, EV a.c.)
0.2xI∆N ... 1.5xI∆N (A, I∆N ≥30 mA)
0.2xI∆N ... 2.2xIvN (A, I∆N <30 mA)
0.2xI∆N ... 2.2xI∆N (B, MI, EV d.c.)
0.05xI∆N
±0.1xI∆N
0.00 Ω ... 9.99 Ω
10.0 Ω ... 99.9 Ω
100 Ω ... 999 Ω
1.00 kΩ ... 9.99 kΩ
0.01 Ω
0.1 Ω
1Ω
10 Ω
±(5 % of r. + 5 digits)
0.01 Ω
0.1 Ω
1Ω
10 Ω
±(5 % of r. + 5 digits)
Zs RCD 4
0.00 Ω ... 9.99 Ω
10.0 Ω ... 99.9 Ω
100 Ω ... 999 Ω
1.00 kΩ ... 9.99 kΩ
TRMS (0, 14 ... 500 Hz)
0 … 550 V
1V
±(2 % of r. + 2 digits)
Frequency
0.00 Hz .. 9.99 Hz
10.0 Hz ... 499.9 Hz
0.01 Hz
0.1 Hz
±(0.2 % of r. + 1 digits)
TRMS,
AC with A 1018, range=20 A
0.0 mA ... 99.9 mA
100 mA ... 999 mA
1.00 A ... 19.99 A
0.1 mA
1 mA
0.01 A
±(5 % of r. + 5 digits)
±(3 % of r. + 3 digits)
±(3 % of r.)
TRMS,
AC with A 1019, range=20 A
0.0 mA ... 99.9 mA
100 mA ... 999 mA
1.00 A ... 19.99 A
0.1 mA
1 mA
0.01 A
Indicative
±(5 % of r.)
±(3 % of r.)
TRMS,
0.00 A ... 1.99 A
AC/DC with A 1391, range=40 A 2.00 A ... 19.99 A
20.0 A ... 39.9 A
0.01 A
0.01 A
0.1 A
±(3 % of r. + 3 digits)
±(3 % of r.)
±(3 % of r.)
TRMS,
0.00 A ... 19.99 A
AC/DC with A 1391, range = 300 A 20.0 A ... 39.9 A
40.0 A ... 299.9 A
0.01 A
0.1 A
0.1 A
Indicative
Indicative
±(3 % of r. + 5 digits)
3 wire 5
0.00 Ω ... 19.99 Ω
20.0 Ω ... 199.9 Ω
200.0 Ω ... 9999 Ω
0.01 Ω
0.1 Ω
1Ω
±(5 % of r. + 5 digits)
2 clamp
0.00 Ω ... 19.99 Ω
20.0 Ω ... 30.0 Ω
30.1 Ω ... 39.9 Ω
0.01 Ω
0.1 Ω
0.1 Ω
±(10 % of r. + 10 digits)
±(20 % of r.)
±(30 % of r.)
Specific earth resistance
0.0 Ωm … 99.9 Ωm
100 Ωm ... 999 Ωm
1.00 kΩm ... 9.99 kΩm
10.0 kΩm ... 99.9 kΩm
100 kΩm ... 9999 kΩm
0.1 Ωm
1 Ωm
0.01 kΩm
0.1 kΩm
1 kΩm
±(5 % of r.) for Re 1 Ω … 1999kΩ
±(10 % of r.) for Re 2 kΩ … 19.99kΩ
±(20 % of r.) for Re > 20 kΩ
0.1 mA
±(5 % of r. + 3 digits)
5 kΩ
Indicative values, up to 128 steps
Zline (L-L, L-N), Ipsc,
Zline 4-wire 3
Zloop (L-PE), Ipfc,
Zloop 4-wire 3
VOLTAGE
CURRENT
EARTH
RESISTANCE
POWER
HARMONICS
Power (P, S, Q)
±(10 % of r.)
±(10 % of r.)
0.00 W (VA, Var) ... 99.9 kW (kVA, kVar)
Power factor
-1.00 ... 1.00
Voltage THD
0.1 % ... 99.9 %
Voltage harmonics
0.1 V ... 500 V
Voltage THD
0.1 % ... 99.9 %
Current harmonics and Current THD 0.00 A ... 199.9 A
FIRST FAULT LEAKAGE
CURRENT (ISFL)
ISC 1, ISC 2
IMD TEST
Threshold indicative insulation
5 … 640 kΩ
resistance
0.0 mA ... 19.9 mA
Function
ILLUMINANCE
Measuring range
Resolution
Accuracy
0.01 lux ... 19.99 lux
20.0 lux ... 199.9 lux
200 lux ... 1999 lux
2.00 klux ... 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
±(5 % of r. + 2 digits)
0.01 lux ... 19.99 lux
20.0 lux ... 199.9 lux
200 lux ... 1999 lux
2.00 klux ... 19.99 klux
0.01 lux
0.1 lux
1 lux
10 lux
±(10 % of r. + 3 digits)
Discharging time
0.0 s … 10.0 s
0.1 s
±(5 % of r. + 2 digits)
Peak voltage
0 V … 550 V
1V
±(5 % of r. + 3 digits)
Power supply
7.2 V (4400 mAh Li-Ion battery pack)
Overvoltage category
600 V CAT III; 300 V CAT IV
Protection class
double insulation
COM port
BT, USB, RS232
Weight
1.78 kg
Size ( l x h x w )
252 x 111 x 165 mm
Type B
Type C
DISCHARGING TIME
GENERAL
Measuring current 1 mA ... 3 mA
Threshold current 1 mA
3
Itest = 20 A @ 230 V; 16 ... 400 Hz
4
Itest MAX = 0.5 x I∆N
5
UOC < 30 VAC, ISC < 30 mA, f = 15 Hz
1
2
STANDARDS
Functionality
•EN 61557;
•DIN 5032
Other reference standards for testing:
•IEC/EN/HD 60364-4-41;
•IEC/EN 61008;
•IEC/EN 61009;
•BS 7671;
•AS/NZ 3017;
APPLICATION
•Testing of TT, TN and IT systems;
•Testing of single and multiphase systems;
•Initial and periodic testing of domestic and
industrial installations;
•LV Installation safety testing;
•Maintenance;
•Lightning installations;
•Testing on high and low frequency
installations (industrial, aircraft, railway,
mining, chemistry, ferry boat);
•Construction sites;
•Mobile LV Generator Units;
•Machine and switchboard testing;
•Medical installation testing;
•Fire brigades, ambulance, military and police
vehicles;
•Mobile Video/Audio, Concert Halls, Fairs,
Playgrounds;
•Electrical Vehicle Supply Equipment (EVSE)
testing;
•Observation of insulation trends.
Electromagnetic compatibility (EMC):
•IEC/EN 61326-1
Safety
•IEC/EN 61010-1;
•IEC/EN 61010-031;
•IEC/EN 61010-2-030;
•IEC/EN 61010-2-032
±(5 % of r.)
±(10 % of r.)
ORDERING INFORMATION
OPTIONAL ACCESSORIES
Photo
Order No.
Acc. decription
A 1569
Photo
Order No.
Acc. decription
Power supply 12V 3A
S 2027
Earth test set,
3-wire, 50 m
A 1567
4400mAh battery pack
S 2058
Insulation test plates
A 1568
8800mAh battery pack
A 1012
Test lead, green, 4 m
A 1551
Small carrying bag with
Metrel logo
A 1154
Test lead, black, 4 m
A 1552
Large carrying bag with
Metrel logo
A 1026
Test lead, red, 20 m
P 1101
BASIC to PRO licence
key upgrade for Metrel
ES Manager
A 1153
Test lead, black, 20 m
A 1401
BLK
Tip commander
A 1164
Test lead, black, 50 m
A 1018
Current clamp (low
range, leakage)
S 2012
Continuity test lead,
10 m, 2 pcs (red,
black)
A 1019
Current clamp
S 2025
Test lead, 1.5 m,
2 pcs (black, red)
A 1391
AC/DC Current clamp
A 1198
Magnetic contact
probe
A 1172
Luxmeter sensor, type
B (PS/2)
A 1201
Insulated rod
for CONTINUITY
measurement
A 1173
Luxmeter sensor, type
C (PS/2)
A 1202
Additional extension
part for A 1201
A 1191
Receiver R10K
A 1532
A 1532 EVSE adapter
A 1192
A 1437
Selective probe for
R10K
A 1199
Ro-adapter
Test lead with Kelvin
probe
A 1143
Euro Z 290 A
Standard set MI 3155 ST
• Instrument MI 3155 EurotestXD
• 4400 mAh battery pack
• Power supply adapter 12V/1.3 A wallmount
SA115K-12G ONTOP
• Plug commander, 1.5 m
• Test lead, 4-wire, 1.5 m
• Test lead, 3-wire, 1.5 m
• Test lead, 2-wire, 2,5 kV, 1.5 m
• Test probe, 4 pcs (black, blue, green, red)
• Crocodile clip, 6 pcs (black – 2 pcs, blue – 1
piece, green – 1 piece, red – 2 pcs)
• Earth set 20 m
• USB cable
• Soft carrying bag
• Soft carrying neck belt
• Metrel ES Manager BASIC license*
• Short instruction manual
• Instruction manual (CD)
• Guide for testing and verification of Low
voltage installations (CD)
• Calibration certificate
• Metrel ES Manager (program installation)
A 1481 (CD)
Euro set MI 3155 EU
• MI 3155 ST
• 8800 mAh battery pack instead of 4400
mAh battery pack
• Current clamp A 1018 (low range, leakage)
• Current clamp A 1019
• Metrel ES Manager PRO license*
*Metrel ES Manager can be downloaded free of charge
from Metrel Web server.
METREL D.D.
Measuring and Regulation Equipment Manufacturer
Ljubljanska 77, SI-1354 Horjul, Slovenia
T +386 (0)1 75 58 200, F +386 (0)1 75 49 226
metrel@metrel.si, www.metrel.si
Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery.
Subject to technical change without notice.
Download PDF
Similar pages