DIESEL GENERATOR SET – MODEL MERLIN 6KVA
The Merlin 6KVA air-cooled generator set is designed for rugged
operation. It is easily manoeuvrable by wheels, forklift or strap
lifting points. Service and maintenance panels allow easy access
for oil and air filter inspection and replacement.
CONTROL PANEL
Push Button Start/Stop and reset
Over crank protection
Hours run meter
Automatic low oil shutdown
Automatic low fuel shutdown and alarm
POWER OUTPUT CONNECTIONS
Socket output panel:
2 x 16 Amp sockets @ 230 Volt
2 x 16 Amp sockets @ 115 Volt
1 x 32 Amp socket @ 115 Volt
Output protection:
MCB protected on all sockets
OPTIONAL EXTRAS
Single Voltage: 230V or 110V CTE
Terminal Output
Automatic Mains Failure
Remote Start
Start-On-Demand
RCD
WEIGHTS AND DIMENSIONS
Length:
1225 mm
Width:
732 mm
Height: 883 mm
Weight:
170kg (without fuel)
RATED OUTPUT
Power rating
Power Factor
Freq’s
Voltages
4.8 kW (6.0kVA)
0.8
50 Hz
115 - 230 Volts
ENGINE
Make
Model
Cooling
Speed
Bhp
Displacement
Fuel
Consumption
Starting system
Battery
Charging System
Yanmar
L100
Forced air cooled
3000 rpm
8.8 BHP @ rated speed
406cc
Diesel
1.65 Litres per hour @ 75 % load
Electric starter motor 12Vdc
12 Volt Lead Acid
Regulated engine mounted charger 8 Amp
ALTERNATOR
Make
Model
Rated output
Bearings
Poles
Insulation Class
IP rating
Regulation
Sincro
EK2-6
4.8 kW (6.0kVA)
Single Bearing
Two pole
H
IP 21
± 1.5%
WHEELED CANOPY
Material
Mild steel
Handles
Folding secured by R clips
Paint
Polyester powder coated
Fuel tank
Frame mounted
Fuel tank capacity 17 Litres
Running time
10 Hours
Sound level
95 LWA (69 dB(A) @ 7 metres)
Fuel Fill
External
Access
2 x Access covers for Air and Oil
Oil Drain
Flexible pipe drain to external access
UK Head Office: Unit 2 Skyways, Exeter Airport Business Park, Exeter, Devon EX5 2UL Tel: +44 (0)1392 449080
Fax: +44 (0)1392 449088 E-mail: info@hawkmoor.com Web: www.hawkmoor.com Registered Company Number: 2619305
Revised July 2009