PROFIBUS DP/CANopen Gateway PCO-150S

SiboTech Gateway Selection Guide
SiboTech
EtherNet IP
Modbus TCP
Modbus TCP
PROFIBUS
DeviceNet
DeviceNet
CANopen
CANopen
CAN2.0A
Modbus
Modbus
HART
RS485/RS422
Gateway
Server
Client
Server
DP Slave
Slave
Master
Master
Slave
/2.0B
Master
Slave
Master
/RS232
EtherNet IP
EPS-320IP
Server
Modbus TCP
Modbus TCP
EPS-320IP
EP-321MP
EP-321MP
DeviceNet
DeviceNet
ENC-310
ENC-316
CANopen
/2.0B
PD-100S
ENC-311
ENB-301MT
PM-160
Master
/ENB-302MI
/ENB-302MT
/PM-127
Modbus
ENB-301MT
PM-160
Slave
/ENB-302MT
/PM-127
RS485/RS422
/RS232
PCO-150S
PCA-100
PM-160
PM-160
/PM-127
/PM-127
PM-160
MD-210
MD-21T
MCO-242
MCO-241
PCA-100
ENB-301MI
Master
PCO-150
PCO-150
Modbus
HART
PD-100
HME-635
/ENB-302MT
PCO-150S
Slave
CAN2.0A
ENB-301MT
ENC-316
PD-100
Master
Master
/ENB-302MI
/ENB-302MT
PD-100S
Slave
CANopen
ENB-301MI
ENB-301MT
EP-321MP
Slave
Slave
ENC-311
EP-321MP
Master
PROFIBUS DP
ENC-310
HME-635
MCA-240
MD-210
SS-430
MCO-241
MCO-242
/SS-431
MCA-240
HPM-610
PM-160
MD-21T
SCA-102
SCA-102
HTM-611
SS-430
/HTM-631
/SS-431
HTM-611
HTM-611
//HTM-631
/HTM-631
SS-430
HTM-611
/SS-431
/HTM-631
SiboTech Converter Selection Guide
SiboTech
Converter
PROFIBUS DP
Slave
DeviceNet
Slave
CANopen
Slave
Modbus
Master
RS485/RS422
/RS232
PROFIBUS DP
Slave
PM-125
PM-125
DeviceNet
Slave
MD-21U
MD-21T
/SD-10
CANopen
Slave
MCC-425
Modbus
Master
PM-125
MD-21U
RS485/RS422
/RS232
PM-125
MD-21T
/SD-10
MCC-425
Embedded Fieldbus and Ethernet Module Selection Guide
Embedded
Module
Fieldbus
CPD-511
PROFIBUS DP
Slave
UART/SPI
SiboTech Generi Communication Protocol
CCO-512
CANopen
Slave
UART
SiboTech Generi Communication Protocol
EtherNet
Embedded
Interface
Embedded Interface Protocol
EMT-331
Modbus TCP
Slave
UART
SiboTech Generi Communication Protocol
/Modbus master
EIP-341
EtherNet IP
Slave
UART
SiboTech Generi Communication Protocol
Table of Contents
SiboTech Gateway..................................................................................................................................................- 1 Serial/PROFIBUS DP Gateway PM-160..........................................................................................................- 1 Modbus/PROFIBUS DP Gateway PM-127......................................................................................................- 2 PROFIBUS DP/CAN Gateway PCA-100........................................................................................................ - 3 DeviceNet/PROFIBUS DP Gateway PD-100.................................................................................................. - 4 PROFIBUS DP/DeviceNet Gateway PD-100S................................................................................................ - 5 PROFIBUS DP/CANopen Gateway PCO-150.................................................................................................- 6 PROFIBUS DP/CANopen Gateway PCO-150S.............................................................................................. - 7 HART / PROFIBUS DP Gateway HPM-610................................................................................................... - 8 HART / Modbus Gateway HTM-631/HTM-611.............................................................................................. - 9 HART / Modbus TCP Gateway HME-635..................................................................................................... - 10 EtherNet IP /PROFIBUS DP Gateway EPS-320IP.........................................................................................- 11 Modbus TCP/PROFIBUS DP Gateway EP-321MP.......................................................................................- 12 Serial/DeviceNet Gateway MD-210...............................................................................................................- 13 RS485/DeviceNet Converter MD-21T/SD-10................................................................................................- 14 DeviceNet Extender DET-141........................................................................................................................ - 15 Modbus/Nonstandard Protocol Gateway SS-430........................................................................................... - 16 Modbus/Nonstandard Protocol Gateway SS-431........................................................................................... - 17 Modbus RTU/EtherNet IP Gateway ENB-302MI/ENB-301MI..................................................................... - 18 Modbus RTU/Modbus TCP Gateway ENB-302MT/ENB-301MT................................................................ - 19 Modbus /CAN Gateway MCA-240................................................................................................................ - 20 RS232 (RS485)/CAN Converter SCA-102.................................................................................................... - 21 Modbus/CANopen Gateway MCO-241......................................................................................................... - 22 CANopen/Modbus Gateway MCO-242......................................................................................................... - 23 CANopen/EtherNet IP Gateway ENC-310.....................................................................................................- 24 CANopen/Modbus TCP Gateway ENC-316.................................................................................................. - 25 CAN/Ethernet Gateway ENC-315..................................................................................................................- 26 SiboTech Converter.............................................................................................................................................. - 27 RS485/PROFIBUS DP Converter PM-125.................................................................................................... - 27 Modbus/DeviceNet Converter MD-21U........................................................................................................ - 28 Modbus/CANopen Converter MCC-425........................................................................................................- 29 SiboTech Embedded Fieldbus and EtherNet Module...........................................................................................- 30 Embedded PROFIBUS DP Interface Module CPD-511.................................................................................- 30 Embedded CANopen Interface Module CCO-512......................................................................................... - 31 Embedded EtherNet/IP Interface Module EIP-341........................................................................................ - 32 Embedded Modbus TCP Interface Module EMT-331.................................................................................... - 33 -
SiboTech Gateway
/PROFIBUS DP Gateway PM-160
Serial
Serial/PROFIBUS
Description
Description:
Need to convert your serial Modbus RTU/ASCII (RS232, RS422 or RS485) devices to PROFIBUS DP network,
the PM-160 does the job.You can also convert your nonstandard protocol devices to PROFIBUS DP with PM-160.
Technical Specification
Specification:
1)
Support debugging in case of no PROFIBUS DP master
2)
Serial RS232, RS422 and RS485 interfaces on board, baud rate up to
115200bps
3)
Act as Modbus RTU/ASCII master at the side of serial ,support 01H, 02H ,
03H, 04H, 05H, 06H, 0FH and 10H function codes
4)
Act as Modbus RTU / ASCII salve at the side of serial, support 03H, 04H,
06H and 10H function codes
5)
Support nonstandard protocols at the side of serial
6)
Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS DP
baud rate is self-adaptive and up to 12M
7)
Support max. 244 bytes input and 244 bytes output data
8)
Easy configuration with free PMG-123 software tool
9)
Power: 24VDC (11~30V), 80mA (24VDC)
10) Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
11) Mounting: 35mm standard rail
-1-
Modbus/PROFIBUS DP Gateway PM-127
Description
Description:
Need to convert your serial Modbus RTU/ASCII (RS485) devices to PROFIBUS DP network, the PM-127 does
the job.
Technical Specification
Specification::
1) Serial RS485 on board, baud rate up to 115200bps
2) Act as Modbus RTU /ASCII master at the side of serial, support 01H, 02H ,
03H, 04H, 05H, 06H, 0FH and 10H function codes
3) Act as Modbus RTU/ASCII slave at the side of serial, support 01H, 02H ,
03H, 04H, 05H, 06H, 0FH and 10H function codes
4) Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS DP
baud rate is self-adaptive and up to 12M
5) Support max. 244 bytes input and 244 bytes output data
6) Support monitoring status of Modbus commands or network from
PROFIBUS DP network
7) Set Modbus communication parameters in PROFIBUS DP host configuration software
8) Power: 24VDC (11~30V), 80mA (24VDC)
9) Mechanical Dimension: 115mm(D) * 18mm(W) * 100mm(H)
10) Mounting: 35mm standard rail
Note: PM-126B support the function of PM-127, but the serial of PM-126B is RS232 when PM-127 is RS485.
-2-
PROFIBUS DP/CAN Gateway PCA-100
Description
Description:
Connect multiple CAN2.0A/2.0B devices to PROFIBUS DP network. Support J1939 protocol devices connecting
to PROFIBUS DP master.
Technical Specification
Specification:
1)
Support multiple CAN2.0A/2.0B devices
2)
CAN baud rate up to 1Mbps
3)
Act as PROFIBUS DP slave at the side of PROFIBUS DP,
PROFIBUS DP baud rate is self-adaptive and up to 12M
4)
Support 16 or 15 bytes input and output data
5)
2.5KV photoelectric isolated PROFIBUS DP and CAN interfaces
6)
Redundant power supply
7)
Power: 24VDC (9~30V)
8)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
9)
Mounting: 35mm standard rail
-3-
DeviceNet/PROFIBUS DP Gateway PD-100
n:
Descriptio
Description:
Connect DeviceNet salve devices to PROFIBUS DP network.
Technical Specification
Specification:
1)
Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS DP baud rate is self-adaptive and up
to 12M
2)
2.5KV photoelectric isolated PROFIBUS DP and DeviceNet interfaces
3)
Act as DeviceNet master at the side of DeviceNet, support Poll I/O
4)
DeviceNet baud rate support: 125K, 250 and 500K
5)
Support 112 or 48 bytes input and output data
6)
Easy configuration with free PD-123 software tool
7)
Support scanning DeviceNet slave devices with DNetStart software in
operation mode
8)
9)
Can using DeviceNet network power , and power: 24VDC (11~30V)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
10) Mounting: 35mm standard rail
-4-
PROFIBUS DP/DeviceNet Gateway PD-100S
Description
Description:
Connect DeviceNet master device to PROFIBUS DP network and establish the communication between them.
Technical Specification
Specification:
1)
Act as PROFIBUS DP slave at the side of PROFIBUS DP,
PROFIBUS DP baud rate is self-adaptive and up to 12M
1) 2.5KV photoelectric isolated PROFIBUS DP and DeviceNet
interfaces
2) Act as Group 2 Only Server at the side of DeviceNet and support
DeviceNet I/O POLL
3) Support max. 112 bytes input and 112 bytes output data
4) Support Hyper Terminal in configuration mode
5) Good real-time, the delay of data exchange is millisecond
6) Can using DeviceNet network power, and power: 24VDC (11~30V)
7) Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
8) Mounting: 35mm standard rail
-5-
PROFIBUS DP/CANopen Gateway PCO-150
Description
Description:
Connect multiple devices with CANopen slave interface to PROFIBUS DP network, and establish the
communication between them.
Technical Specification
Specification:
1)
Act as a master at the side of CANopen, and CANopen baud rate up to 1M
2)
CANopen interface has1KV photoelectric isolation
3)
Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS DP baud
rate is self-adaptive and up to 12M
4)
Max. 244 bytes input and 244 bytes output data
5)
Support CAN2.0A, and in accordance with DS-301 V4.02 and CiA Draft
Recommendation 303
6)
Support Life guard, Heartbeat and NMT functions
7)
Easy configuration with free PC-123 software tool
8)
Power: 24VDC (11~30V), 90mA(24V)
9)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
10) Mounting: 35mm standard rail
-6-
PROFIBUS DP/CANopen Gateway PCO-150S
Description
Description:
Connect a device with CANopen master interface to PROFIBUS DP network, and establish the communication
between them.
Technical Specification
Specification:
1)
Act as a slave at the side of CANopen, and CANopen baud rate up to
1M
2)
CANopen interface has1KV photoelectric isolation
3)
Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS
DP baud rate is self-adaptive and up to 12M
4)
Support max. 244 bytes input and 244 bytes output data
5)
Support CAN2.0A, and in accordance with DS-301 V4.02 and CiA
Draft Recommendation 303
6)
Support CANopen master monitoring status of PROFIBUS DP network
and reset communication, reset node and reset application of the Gateway
7)
Easy configuration with free PC-123 software tool
8)
Power: 24VDC (11~30V), 90mA(24V)
9)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
10) Mounting: 35mm standard rail
-7-
HART / PROFIBUS DP Gateway HPM-610
Description:
Connect HART slave devices to PROFIBUS DP master and realize data communication.
Technical Specification:
1)
Support a HART channel and connect 13 devices when using built-in resistance and 15 devices when using
an external resistor (250Ω)
2)
Act as a primary master or secondary master at the side of HART, support burst mode, long frame format and
all HART commands
3)
HART buffer up to 1600 bytes input and 1600 bytes output, each channel
can be configured up to 128 commands, and each command
support
four kinds of mode of outputting commands: polling output,
change-of-state output, initialization output, and disable output
4)
Support internal or external sampling resistor
5)
Easy configuration with free HT-123 software tool and support
monitoring and debugging HART commands
6)
Support max. 244 bytes input and 244 bytes output PROFIBUS DP data
7)
Support PROFIBUS DP slave, PROFIBUS DP baud rate is self-adaptive and up to 12M
8)
Support PROFIBUS DP input data more than mistakenly cleared or maintain function;
9)
Act as Modbus RTU/ASCII slave at the side of serial ,interface support RS232, RS485, RS422 and baudrate
up to 115200kps
10) Support nonstandard protocols at the side of serial
11) Power: 24VDC (11~30V), 80mA(24V DC)
12) Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
13) Mounting: 35mm standard rail
-8-
31/HTM-611
HART / Modbus Gateway HTM-6
M-631/HTM-611
Description:
Connect HART slave devices to Modbus master and realize data communication.
Technical Specification:
1)
Support a HART channel and connect 13 devices when using built-in
resistance and 15 devices when using an external resistor (250Ω)
2)
Act as a primary master or secondary master at the side of HART, support
burst mode, long frame format and all HART commands
3)
HART buffer up to 1000 bytes input and 1600 bytes output, each channel
can be configured up to 128 commands, and each command
support four
kinds of mode of outputting commands: polling output, change-of-state
output, initialization output, and disable output
4)
Support internal or external sampling resistor
5)
Easy configuration with free HT-123 software tool and support monitoring
and debugging HART commands
6)
Support Modbus RTU/ASCII slave at the side of serial ,interface support RS232, RS485, RS422 and baudrate
up to 115200kps, support 03H, 04H, 06H and 10H function codes
7)
Support nonstandard protocols at the side of serial
8)
Power: 24VDC (11~30V), 80mA(24V DC)
9)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
10) Mounting: 35mm standard rail
Note: HTM-611 support only one channel, but HTM-631 support three channels. The performance of three
channels of HTM-631 is the same.
-9-
HART / Modbus TCP Gateway HME-635
Description:
Connect HART slave devices to Modbus TCP network and realize data communication.
Technical Specification:
1)
Support three HART channel and each channel can connect 13 devices when
using built-in resistance and 15 devices when using an external resistor (250Ω)
2)
Act as a primary master or secondary master at the side of HART, support burst
mode, long frame format and all HART commands
3)
HART buffer up to 3000 bytes input and 2000 bytes output, each channel can be
configured up to 100 commands, and each command
support four kinds of
mode of outputting commands: polling output, change-of-state output,
initialization output, and disable output
4)
Ethernet 10/100M adaptive adaptive; IP address conflict detection; automatic
routing functions;
5)
Modbus TCP up to 36 connections, Modbus TCP can support 512 command request;
6)
Easy configuration with free HTConfig-123 software tool
7)
Power: 24VDC (11~30V), 80mA(24V DC)
8)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
9)
Mounting: 35mm standard rail
- 10 -
EtherNet IP /PROFIBUS DP Gateway EPS-320IP
:
Description
Description:
Connect PROFIBUS DP master device to EtherNet IP network and establish the communication between them.
:
Technical Specification
Specification:
1)
Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS DP
baud rate is self-adaptive and up to 12M
2)
Support max. 244 bytes input and 244 bytes output data
3)
1KV photoelectric isolated PROFIBUS DP interface
4)
Support ODVA standard EtherNet IP communication protocol
5)
EtherNet IP support three groups I/O connection at the same time
6)
EtherNet IP support both ways reading and writing I/O data:
a)
Directly establish the I/O connection to read and write I/O data
b)
Using MSG instructions to read and write I/O data
7)
Support monitoring the other network connection status
8)
Support byte swapping: no swapping, double-byte swapping and four-byte swapping
9)
Power supply 24VDC (11V ~ 30V);
10) Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
11) Mounting: 35mm standard rail
- 11 -
Modbus TCP/PROFIBUS DP Gateway EP-321MP
:
Description
Description:
Connect PROFIBUS DP master device to Modbus TCP network and establish the communication between them.
:
Technical Specification
Specification:
1) Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS DP
baud rate is self-adaptive and up to 12M
2) Support max. 244 bytes input and 244 bytes output PROFIBUS DP data
3) Act as Modbus TCP client, support up to 36 Modbus TCP servers that with
different IP or different identifiers, and support 01H, 02 H, 03 H, 04 H, 05
H, 06H, 0FH and 10H function codes
4) Act as a Modbus TCP server, support up to 36 TCP connections, and
support 03H, 04H, 06H, and 10H function codes
5) 1KV photoelectric isolated PROFIBUS DP interface
6)
Power supply 24VDC (11V ~ 30V);
7) Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
8) Mounting: 35mm standard rail
- 12 -
/DeviceNet Gateway MD-210
Serial
Serial/DeviceNet
Description
Description:
Connect multiple Modbus devices with Modbus RS485/RS232 interface to DeviceNet network.
Technical Specification
Specification:
1) Support debugging in case of no DeviceNet master
2) Act as DeviceNet slave at the side of DeviceNet network and Modbus
master at the side of serial port
3) Serial RS485/RS232 on board and baud rate up to115200bps
4) DeviceNet interface baud rate: 125K, 250K, 500K and baud rate interception
5) Max. 160 bytes input and 112 bytes output data
6) Easy configuration with free GT-123 software tool
7) Power: 24VDC (11~30V), 80mA (24VDC)
8) Mechanical Dimension: 45mm(D) * 110mm(W) * 125mm(H);
9) Mounting: 35mm standard rail
- 13 -
485
/DeviceNet Converter MD21T/SD-10
RS
RS485
485/DeviceNet
D-21T/SD-10
Description
Description:
Connect a device with RS232 interface to DeviceNet network.
Technical Specification
Specification:
1)
Act as DeviceNet Group2 only slave at the side of DeviceNet, support
baud rate: 125K, 250K, 500K and baud rate interception
2)
Serial RS232 on board, baud rate up to 115200bps
3)
Support users’ defined protocol through programming in DeviceNet
master PLC
7)
4)
Easy configuration with super terminal
5)
Power: 24VDC (9~30V), 80mA (24V)
6)
Mechanical Dimension: 70mm(D) * 25mm(W) * 100mm(H)
Mounting: 35mm standard rail
Note
Note: SD-10 support the function of MD-21T, but the serial of SD-10 is RS232 when MD-21T is RS485.
- 14 -
DeviceNet Extender DET-141
Description
Description:
DeviceNet Extender can extend length of DeviceNet network.
Technical Specification
Specification:
1)
Support DeviceNet protocol
2)
Multiple extenders support Daisy Chain connection
3)
Left interface support baud rate: 125K, 250K, 500K and baud rate
interception; Right interface baud rare:125Kbps
4)
Act as a DeviceNet node on network
5)
Can using DeviceNet network power, and power: 24VDC (11~30V)
6)
DeviceNet interfaces use 5-pin pluggable terminals
- 15 -
Modbus/Nonstandard Protocol Gateway SS-430
Description
Description:
Need to convert your serial nonstandard protocol devices to Modbus RTU/ASCII, the SS-430 product does the
job.
Technical Specification
Specification:
1)
Serial RS485/RS422/RS232 on board and baud rate up to115200bps
2)
Provide four serial interfaces and can act as Modbus master, Modbus slave, Universal mode and simple
defined protocol by SiboTech.
3)
Support two Modbus master access the same Modbus network
4)
Act as a Modbus RTU/ASCII master at the side of serial, support 01H,
02H , 03H, 04H, 05H, 06H, 0FH and 10H function codes
5)
Act as a Modbus RTU/ASCII slave at the side of serial, support 03H,
04H, 06H and 10H function codes
6)
Support data exchange between Modbus slaves without PLC or DCS
7)
Easy configuration with free SS-123 software tool
8)
Max.1K bytes input and 1K bytes output data
9)
Serial interface has3KV isolation
10) Power: 24VDC (11~30V), <140mA (24VDC)
11) Mechanical Dimension: 70mm(D) * 25mm(W) * 100mm(H);
12) Mounting: 35mm standard rail
- 16 -
1
Modbus/Nonstandard Protocol Gateway SS-43
SS-431
Description:
All RS232/RS485 devices can communicate with other serial devices with the gateway SS-431.
Technical specifications
specifications:
1)
Support two serial ports, and baud rate up to115200bps; SerialⅠis
RS-485 and serialⅡis RS-485 or RS-232(Please specify when you place
an order.)
2)
Serial protocol support: Modbus master, Modbus slave, SiboTech
specification protocol, and other nonstandard serial protocol
3)
Act as Modbus RTU/ASCII master, support 01H, 02H, 03H, 04H, 05H,
06H, 0FH and10H function codes, support up to 48 Modbus commands
4)
Act as Modbus RTU/ASCII slave, support 03H, 04H, 06H and 10H
function codes
5)
Support other nonstandard serial protocol:
6)
Max.1K bytes input and 1K bytes output data
7)
Power: 24VDC (11~30V), <140mA (24VDC)
8)
Mechanical Dimension: 115mm(D) * 18mm(W) * 100mm(H);
9)
Mounting: 35mm standard rail
- 17 -
/ENB-301MI
Modbus RTU/EtherNet IP Gateway ENB-302MI
ENB-302MI/ENB-301MI
Description
Description:
Connect Modbus RTU/ASCII (RS485/RS232) devices to Ethernet IP interface.
Technical Specification
Specification:
1)
Act as EtherNet IP server at the side of Ethernet
2)
10/100M EtherNet IP
3)
IP address conflict detection
4)
Act as Modbus RTU master at the side of serial, support 01H, 02H , 03H, 04H,
05H, 06H, 0FH and 10H function codes
5)
Two serial RS485 or RS232 on board and baud rate up to115200bps, has1KV
photoelectric isolation
9)
6)
Easy configuration with free GT-123 software tool
7)
Max.492 bytes input and 492 bytes output data
8)
Redundant power supplies, Power: 24VDC (11~30V), 90mA (24V)
Mechanical Dimension: 45mm(D) * 110mm(W) * 125mm(H);
10) Mounting: 35mm standard rail
Note
Note: ENB-301MI supports the function of ENB-302MI, but ENB-301MI has one serial when ENB-302MI has
two serials. ENB-301MI also support universal mode at the side of serial.
- 18 -
/ENB-301MT
Modbus RTU/Modbus TCP Gateway ENB-302MT
ENB-302MT/ENB-301MT
Description
Description:
Connect Modbus (RS485/RS232) devices to Modbus TCP network or connect Modbus TCP servers to Modbus
RTU master device.
Technical Specification
Specification:
1)
Provide two operating modes: Modbus RTU slave mode and Modbus
RTU master mode
2)
Two serial RS485 or RS232 on board and baud rate up to 230400bps,
has1KV photoelectric isolation
3)
10/100M Modbus TCP
4)
IP address conflict detection
5)
Easy configuration with free MT-123 software tool
6)
Support up to 36 Modbus TCP connections and 512 requests at the same
time
7)
Support mapping of slave ID and automatic routing function
8)
Support priority control of master requests and network security setting
9)
Redundant power supplies, Power: 24VDC (11~30V), <100mA (24VDC)
10) Mechanical Dimension: 45mm(D) * 110mm(W) * 125mm(H);
11) Mounting: 35mm standard rail
Note
Note: ENB-301MT supports the function of ENB-302MT, but ENB-301MT has one serial when ENB-302MT has
two serials.
- 19 -
Modbus /CAN Gateway MCA-240
Description
Description:
Modbus master device i.e. PLC, Controller, can transmit and receive CAN2.0A/2.0B data through the product
MCA-240.
Technical Specification
Specification:
1) Serial RS485 on board and baud rate up to115200bps
2) Act as Modbus RTU slave at the side of serial, support 03H, 04H and 10H
function code
3) Provide a CAN2.0A/2.0B interface
4) CAN baud rate up to 1M ,CAN interface has 1.5KV photoelectric isolated
5) Easy configuration with free MC-123 software tool
6) Power: 24VDC (11~30V), 80mA (24V)
7) Mechanical Dimension: 25mm(D) * 70mm(W) * 100mm(H)
8) Mounting: 35mm standard rail
- 20 -
/CAN Converter SCA-102
RS232 (RS485)
(RS485)/CAN
Description
Description:
Can help user realize the data bidirectional exchange between PC or RS232/RS485 devices and CAN devices.
Technical Specification
Specification:
1)
Provide a CAN2.0A/CAN2.0B interface, baud rate up to 1Mbps
2)
CAN interfaces adopts photoelectric isolation and DC-DC power
isolation
3)
Two operation mode: Transparent transmission and Transparent
transmission with ID
4)
Serial RS232 or RS485 on board and baud rate up to 115200bps
5)
Serial receiving buffer: 4.5KB (15*300Byte)
6)
CAN receiving buffer: 1.6KB (200*8Byte)
7)
Easy configuration with free SC-123 software tool
8)
CAN set delay time between frames in SC-123: 2~20 character time
9)
CAN set
most 13 CAN filters in SC-123
10) Power: 24VDC (11~30V), <60mA(24V)
11) Mechanical Dimension: 25mm(D) * 70mm(W) * 100mm(H)
12) Mounting: 35mm standard rail
- 21 -
Modbus/CANopen Gateway MCO-241
Description
Description:
Connect multiple Modbus slave devices to CANopen network.
Technical Specification
Specification:
1)
Act as CANopen master at the side of CANopen network
2)
Provide a CAN2.0A interface, baud rate up to 1Mbps
3)
CAN interface has 1KV photoelectric isolated
4)
Serial RS485 on board and baud rate up to115200bps
5)
Act as Modbus RTU/ASCII master at the side of serial, support 01H, 02H ,
03H, 04H, 05H, 06H, 0FH and 10H function codes
6)
Max. 512 bytes input and 512 bytes output data
7)
Easy configuration with free CM-123 software tool
8)
Power: 24VDC (11~30V), <60mA(24V)
9)
Mechanical Dimension: 25mm(D) * 70mm(W) * 100mm(H)
10) Mounting: 35mm standard rail
- 22 -
CANopen/Modbus Gateway MCO-242
Description
Description:
Connect multiple CANopen slave devices to Modbus network.
Technical Specification
Specification:
1)
Provide a CAN2.0A interface, and act as CANopen slave, baud rate
up to 1M
2)
CAN interface has 1KV photoelectric isolated
3)
Serial RS485 on board and baud rate up to115200bps
4)
Act as Modbus RTU/ASCII slave at the side of serial, support 03H,
04H, 06H, and 10H function codes
5)
Max. 512 bytes input and 512 bytes output data
6)
Easy configuration with free CM-123 software tool
7)
Power: 24VDC (11~30V), 60<mA(24V)
8)
Mechanical Dimension: 25mm(D) * 70mm(W) * 100mm(H)
9)
Mounting: 35mm standard rail
- 23 -
Net IP Gateway ENC-31
0
CANopen/Ether
CANopen/EtherN
ENC-310
Description
Description:
Connect CANopen slave devices to EtherNet IP network.
Technical Specification
Specification:
1)
Act as CANopen master at the side of CANopen network and EtherNet
IP server at the
2)
side of Ethernet
Provide a CAN2.0A interface, baud rate up to 1Mbps, and has1KV
photoelectric isolation
3)
In accordance with DS-301 V4.02 and CiA Draft Recommendation 303
4)
Support PDO and fast SDO of CANopen protocol
5)
10/100M EtherNet IP
6)
IP address conflict detection
7)
Easy configuration with free EC-123 software tool
8)
Power: 24VDC (11~30V), 90mA(24V)
9)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
10) Mounting: 35mm standard rail
- 24 -
Modbus TCP Gateway ENC-31
6
CANopen/
CANopen/Modbus
ENC-316
Description
Description:
Connect CANopen slave devices to Modbus TCP network.
Technical Specification
Specification:
1) Act as CANopen master at the side of CANopen network and Modbus TP
server at the
side of Ethernet
2) Provide a CAN2.0A interface, baud rate up to 1Mbps, and has1KV
photoelectric isolation
3) In accordance with DS-301 V4.02 and CiA Draft Recommendation 303
4) Support PDO and fast SDO of CANopen protocol
5) Support NMT, SYNC and Lifeguard function
6) In accordance with standard Modbus TCP protocol
7) 10/100M Modbus TCP
8) IP address conflict detection
9) Easy configuration with free EC-123 software tool
10)
Power: 24VDC (11~30V)
11)Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
12)
Mounting: 35mm standard rail
- 25 -
Ethernet Gateway ENC-315
CAN/
CAN/Ethernet
Description
Description:
Connect multiple CAN devices to TCP/IP.
Technical Specification
Specification:
1)
Provide a CAN2.0A/2.0B interface, baud rate up to 1Mbps and has 1KV
photoelectric isolation
2)
10/100M TCP/IP
3)
Can be TCP client or server at the side of Ethernet
4)
IP address conflict detection
5)
Easy configuration through Web, provide test program and DLLs
6)
Power: 24VDC (9~30V), <2.5W (24V)
7)
Mechanical Dimension: 110mm(D) * 40mm(W) * 125mm(H)
8)
Mounting: 35mm standard rail
- 26 -
SiboTech Converter
/PROFIBUS DP Converter PM-125
RS485
RS485/PROFIBUS
Description
Description:
Connect single device with Modbus RTU/ASCII or nonstandard protocol serial RS485 device to PROFIBUS DP.
Technical Specification
Specification:
1)
Serial RS485 on board, baud rate up to 115200bps
2)
Act as Modbus RTU or ASCII master at the side of serial, support 01H,
02H , 03H, 04H, 05H, 06H, 0FH and 10H function codes
3)
Support nonstandard protocols at the side of serial
4)
Only connecting a device is possible at the side of serial
5)
Act as PROFIBUS DP slave at the side of PROFIBUS DP, PROFIBUS
DP baud rate is self-adaptive and up to 12M
6)
Max. 168 bytes input and 168 bytes output data
7)
Easy configuration with free PMA-123 software tool
8)
Power: 24VDC (11~30V), 80mA (24VDC)
9)
Mechanical Dimension: 25mm(D) * 70mm(W) * 100mm(H)
10) Mounting: 35mm standard rail
Note
Note: PM-126A support the function of PM-125, but the serial of PM-126A is RS232 when PM-125 is RS485.
- 27 -
Modbus/DeviceNet Converter MD-21U
Description
Description:
Connect a device with Modbus RS485/422 interface to DeviceNet network.
Technical Specification
Specification:
1)
Act as DeviceNet slave at the side of DeviceNet and Modbus master at
the side of serial port
2)
Serial RS485/RS422 on board and baud rate up to115200bps
3)
DeviceNet interface baud rate: 125K, 250K, 500K and baud rate
interception
4)
Max. 96bytes input and 64 bytes output data
5)
Easy configuration with free GT-123 software tool
6)
Power: 24VDC (8~30V), 80mA (24VDC)
7)
Mechanical Dimension: 70mm(D) * 25mm(W) * 100mm(H);
- 28 -
C-425
Modbus/CANopen Converter MC
MCC
Description
Description:
Connect multiple Modbus slave devices to CANopen network.
Technical Specification
Specification:
1)
Act as CANopen master at the side of CANopen network
2)
Provide a CAN2.0A interface, baud rate up to 1Mbps
3)
CAN interface has 1KV photoelectric isolated
4)
Serial RS485 on board and baud rate up to115200bps
5)
Act as Modbus RTU/ASCII master at the side of serial, support 01H,
02H , 03H, 04H, 05H, 06H, 0FH and 10H function codes
6)
Max. 512 bytes input and 512 bytes output data
7)
Easy configuration with free CM-123 software tool
8)
Power: 24VDC (11~30V), <60mA(24V)
9)
Mechanical Dimension: 25mm(D) * 70mm(W) * 100mm(H)
10) Mounting: 35mm standard rail
- 29 -
SiboTech Embedded Fieldbus and EtherNet Module
Embedded PROFIBUS DP Interface Module CPD-511
Description
Description:
Embedded PROFIBUS DP interface module CPD-511/501 is a kind of compact embedded module series of
SiboTech. The module series are embedded with the same interface (Hardware) and the interface protocol
(Software). Users only need to develop the hardware and software one time, and you can let the device has a
variety of fieldbus interfaces.
Technical Specification
Specification:
1) The fieldbus interface support PROFIBUS DP V1 slave
2) PROFIBUS DP baud rate is self-adaptive and up to
12Mbps
3) Max. 244 bytes input and 244 bytes output data
4) Length of data records (non-cyclic data) buffer is 244bytes
5) Length of diagnostic buffer is 244 bytes
6) Maximum bytes number of parameter data is 54
7) Maximum bytes number of configuration data is 64
8) PROFIBUS DP interface is 1KV isolated
9) CPD-501 support Parallel, UART and SPI interfaces; CPD-511 support UART and SPI interfaces
10) Power: 3.3VDC, power consumption: less than 1W
11) Operating temperature: -20 ~ 60 ℃
12) Humidity: 5 to 95% (No Condensing)
13) Mechanical Dimension: 49mm (L)*40mm (W)*20mm(H);
- 30 -
Embedded CANopen Interface Module CCO-512
Description
Description:
Users do not need in-depth understanding of the specific details of the CANopen protocol. Through the use of
CCO-512 can easily make the user's device with the CANopen interface. CCO-512 support UART interface.
Technical Specifications:
1)
The compact module is half a business card size, with the CANopen
standard interface, support DB9, open five-pin terminals and
2)
CANopen protocol in accordance with DS-301V4.02, DS-303 and
DS-302
3)
Support max. 20 TPDO and 20 RPDO
4)
Support NMT, Boot up, Heartbeat and Life Guard
5)
Support SYNC
6)
Support the SDO segment access and block access
7)
The maximum input and output bytes up to 160
8)
Act as CANopen slave at the side of fieldbus, baudrate support 5K to 1Mbps
9)
CANopen interface is 1KV isolated
10) Support UART (3.3V), and baudrate up to 1382400bps
11) Power: 3.3VDC, power consumption: less than 1W
12) Operating temperature: -20 ~ 60 ℃
13) Humidity: 5 to 95% (No Condensing)
14) Mechanical Dimension: 50mm (L)*40mm (W)*16.7mm(H)
- 31 -
Embedded EtherNet/IP Interface Module EIP-341
Description
Description:
EIP-341 is an embedded Ethernet IP interface module and it can be used to add an Ethernet IP interface through
UART for user device quickly.
Technical Specification
Specification:
1)
UART interface support simple protocol being defined by Sibotech
2)
Serial port is UART, half duplex, baud rate: 2400, 4800, 9600,
19200, 38400, 57600, 115200, 230400bps, 8 data bits, None Parity,
one stop bit
3)
EtherNet IP interface is 10/100M adaptive
4)
Provide an EtherNet IP server interface, support multiple connections
5)
Support Web Server
6)
User can choose to initialize module through serial port
7)
Power: 3.3VDC(3.14~3.45), 270mA
8)
Mechanical Dimension: 37(mm)*20(mm)*22(mm)
9)
Provide evaluation board
- 32 -
Embedded Modbus TCP Interface Module EMT-331
Description
Description:
EMT-331 is an embedded Modbus TCP interface module and it can be used to add a Modbus TCP interface
through UART for user device quickly.
Technical Specification
Specification:
1)
UART interface support Modbus RTU and simple protocol being
defined by Sibotech
2)
Serial port is UART, half duplex, baud rate: 2400, 4800, 9600, 19200,
38400, 57600, 115200, 230400bps, 8 data bits, None Parity, one stop
bit
3)
Modbus TCP interface is 10/100M adaptive
4)
Provide an Modbus TCP server interface, support 16 connections
5)
Power: 3.3VDC(3.14~3.45), 270mA
6)
Mechanical Dimension: 37(mm)*20(mm)*22(mm)
7)
Provide evaluation board
- 33 -
Download PDF