Additional information at www.testo.com testo 350 S

testo 350-S/-XL
testo 350 is a flexible, portable
analysis system which is basically
made up of a control unit, a flue gas
analyzer and a flue gas probe,
depending on customer
requirements.
testo 350 S/XL, flexible flue gas measuring system
Integrated printer
Prints readings on site
4 user defined
function buttons
Particle filter
The detachable control unit can
control the analysis system and read
out data. The testo 350 XL control
unit can also be used as a separate
hand-held analyzer for differential
pressure (built-in) and also for
temperature, humidity, flow etc.
thanks to its additional probe
socket. Readings are printed on the
built-in printer.
Control unit
Analysis box
Integrated
Peltier gas
preparation unit
The flue gas analyzer is the “heart”
of the analysis system and is
available in two different versions:
• testo 350 S Basic version
• testo 350 XL Advanced version.
The testo 350 S flue gas analyzer is
equipped with a gas sensor for O2
as standard. One sensor must be
fitted or up to 5 additional sensors
for NO (option), NO2 (option), SO2
(option), NOlow (option), CO
(Option), COlow (option), H2S
(option), HC (Option) or CO2 via
infrared gas sensor (option) can be
fitted. Temperature and differential
pressure as well as the usual
parameters such as Δ, qA, etc. are
also calculated.
Integrated differential
pressure probe
Data communication
via PC
Testo data bus
User defined
probe socket
The even more convenient testo
350 XL flue gas analyzer is
equipped with gas sensors for O2,
CO, NO and NO2 as standard.
Additional sensors for HC (option),
NOlow (option), COlow (option), SO2
(Option), H2S (option) or CO2 via
infrared gas sensor (option) are
available. In addition to the features
of the S version, the testo 350 XL
flue gas analyzer also has a Peltier
gas preparation unit with a hose
pump to regulate condensate
disposal as well as a fresh air valve
for long-term measurements lasting
several hours.
Robust housing
with impact
protection
Integrated
differential
pressure/velocity
measurement
Connection for flue
gas probe +
additional
°C temperature probe
Tests and permits
• TÜV Bavaria RgG 211
• Conforms to DIN EN 50379 Part 2
Both versions of the flue gas
analyzers can be equipped with up
to 6 gas sensors, have a built-in
rechargeable battery as standard,
(for battery operation), data logger
(250,000 readings) as well as a
Testo data bus connection.
The testo 350 S flue gas analyzer
can be retrofitted with all the
features/functions of the testo 350
XL flue gas analyzer.
Tests and permits
– TÜV Bayern RgG 211
– Conforms to DIN EN 50379 Part 2
20
Additional information at
www.testo.com
testo 350-S/-XL
testo 350 S/XL, flexible flue gas measuring system
S
XL
testo 350-S control unit
Control unit displays measurement
data and controls measurement
system, built-in printer, connection
for Testo data bus and terminal plug
included
S
testo 350 XL control unit
Control unit displays measurement
data and controls the measurement
system, incl. built-in printer,
pressure measurement 40/200 hPa,
1 user defined probe socket,
programmable measurements and
memory space for 250,000 readings,
connection for Testo data bus, incl.
terminal plug
testo 350-S flue gas
analyser box
XL
testo 350 XL flue gas
analyzer box
testo 350-S flue gas analyser,
equipped with: O2, differential
pressure measurement, 2
temperature probe sockets, testo
data bus connection, built-in
rechargeable battery, data logger,
can be upgraded to max. 6 sensors
(with NO, NO2, CO, H2S, HC, SO2,
CO2 NDIR)
A second gas sensor must be installed in
testo 350-S, otherwise the instrument is
unable to function. Up to 5 additional sensors
can be fitted.
testo 350 XL analyzer box, equipped
with O2, CO (with switch-off and
rinse function), NO, NO2, differential
pressure measurement, 2
temperature probe sockets, gas
preparation, Testo data bus adapter,
automatic fresh air rinse with valve
(including measurement range
extension with dilution factor 5 for all
sensors), built-in rechargeable
battery, data memory, can be
upgraded to max. 6 gas sensors
(with H2S, HC, SO2, CO2 NDIR)
Part no.
Part no.
Part no.
Part no.
0563 0369
0563 0353
0563 0368
0563 0350
Differences between flue gas analysers at a glance
Differences between control units at a glance
testo 350 S
control unit
쐽
Differential pressure measurement (-40 to +40 hPa / -200 to +200 hPa)
쐽
–
1 user-defined probe socket (for e.g. temperature, relative humidity measurement, etc.)
–
쐽
Built-in printer
쐽
Touchscreen
–
쑗
Connection from a flue gas analyzer to the Testo data bus
쐽
Connection of several flue gas analyzers, analog output boxes and testo 454 loggers to the
Testo data bus
쐽
–
NiMH rechargeable battery pack
–
–
Internal memory for 250,000 readings
쐽 = Standard
쑗 = option
– = Not possible
testo 350 S
testo 350 XL
control unit
쐽
쑗
쐽
6
6
O2
0 – 25 Vol.
쐽
쐽
CO (H2)
0 – 10,000 ppm
쑗
쐽
COlow (H2)
0 – 500 ppm
쑗
쑗
NO
0 – 3,000 ppm (0.1 ppm resolution)
쑗
쐽
NOlow
0 – 300 ppm (0.1 ppm resolution)
쑗
쑗
NO2
0 – 500 ppm (0.1 ppm resolution)
쑗
쐽
SO2
0 – 5,000 ppm
쑗
쑗
HC
0 – 4 Vol. % (0.001 % resolution)
쑗
쑗
H2S
0 – 300 ppm (0.1 ppm resolution)
쑗
쑗
CO2 (NDIR)
0 – 50 Vol. %
쑗
쑗
Built-in gas preparation unit (is recommended with high humidity levels in flue gas and
during long-term measurements >2 hrs measuring time)
Automatic fresh air rinse with valve (incl. measurement range extension with dilution factor 5
for all sensors)
쑗
쐽
쑗
쐽
Special gas pump for long-term measurements with extended warranty
쑗
쑗
Measurement range extension for CO gas sensor (with selectable dilution factors)
쑗
쑗
CO gas sensor switch-off via adjustable switch-off threshold
쐽
쐽
Trigger input – stops and starts measurement externally
쑗
쑗
Differential pressure measurement (-40 to +40 hPa / -200 to +200 hPa)
쐽
쐽
Built-in rechargeable battery
쐽
쐽
2 temperature probe sockets (Type K NiCr-Ni)
쐽
쐽
Data logger (250,000 readings)
쐽
쐽
쐽
쐽
Testo data bus connection
쐽 = Standard
Additional information at
testo 350 XL
Maximum no. of gas sensors
쑗 = option
www.testo.com
21
testo 350-S/-XL
Versatile exhaust gas measurement system testo 350-S/-XL
Control unit testo 350-XL
Testo databus controller
with USB connection
Flue gas analyser
testo 350-S/-XL
Testo databus
Logger
testo 454
m/s, t/y
mA out
Power box
ΔhPa, mbar
NOX, SO2,
O2, CO2, ...
m/s, m³/h
The system concept of
testo 350-S
S/-X
XL
For many applications in the industrial
sector, a flue gas analyser with additional
features is needed to fulfill the following
requirements:
• Simultaneous gas and process
analysis at different measurement points
without a time-consuming measurement
point changeover switch
• Option of connecting additional
parameters such as °C; %RH; mA/mV
etc.
• Long-term measurements in order to
be able to assess different system cycles
• Flexibility of system in order to be able
to react to the different requirements of
S/the different systems. The testo 350-S
XL measurement system fulfills these
requirements. Several flue gas analysers,
equipped differently, are connected
together.
22
If several flue gas analysers, for example,
are connected to the Testo data bus,
they can be controlled, read out or
programmed via the following two
options:
• One flue gas analyser after the other
via the testo 350-XL Control Unit, for
example, or via PC and an RS 232 cable
Alternatively:
• Several flue gas analysers
simultaneously via PC and and the Testo
data bus controller with USB
connection.
Additional information at
ΔhPa, Pa
°C
Parameters
Parameters which can be measured
S/-X
XL:
using testo 350-S
a) testo 350-S
S/-X
XL flue gas analyser
• Flue gas parameters such as O2, CO,
NOx, SO2, H2S, HC, CO2(IR)
• Differential pressure, e.g. for
combustion chamber pressure
measurement
• Flow measurement with Pitot tube
The testo 350-S or testo 350-XL flue gas
analysers are positioned at the
respective measurement point. They are
operated either connected to each other
via the Testo data bus or as a separate
datalogger without being connected.
Separate measurement programs are
saved in the flue gas analysers with the
help of the testo 350-XL or PC Control
unit. They include, for example,
start/stop criteria, measurement cycles,
S and
fresh air phases etc. testo 350-S
testo 350-X
XL flue box analysers,
equipped differently, can be used in the
network.
Likewise loggers and analog outputs (6
channels, 4-20mA) can be connected in
this way (only to testo 350-XL Control
Unit ).
%RH
b) Logger box
• Temperature, e.g. of surfaces, liquids
• Humidity, e.g. in suction ducts or
ambient air
• Pressure, e.g. with differential pressure
and high pressure probes
• Flow and volume flow, e.g. with vanes,
hot wire probes
• rpm etc.
www.testo.com
testo 350-S/-XL
Versatile exhaust gas measurement system testo 350-S/-XL
__
__
__
__
Co
__
nt
__
ro
__
__
l u
__
__
ni
__
__
t
__
Sm
it
__
h L
__
__
Mi
td
__
ll
.
to
__
wn
________________________
testo 350 XL
SN: 000321/D
________________________
Smith Ltd.
Milltown
Si
Site
11.2
Date, Time
15:01:01
Fuel:
Readings
:0
08:20:15
Natural gas
1:
2:
ce
01
:2
.6
.3
3 h
P
324
CO
%
522
15
002
01/05
23.6
ppm H2S ppm
5
1:
15
65
CO2
na
14
Site: Furnace 5
Selected
analysis box Page no.
TEST 24
te
: F
ur
Site
name
Status display
16
a
PStop
°C
__
10.9 %
CO2
__
__
_
Z
__
ul
0.45 %
O2
uf
__
tg
__
2348 ppm CO SN:
eb
__
lt
__
0
0
or
_
320 ppm NO
63
__
45
__
15 ppm NO2 ___
__
__
30 ppm SO2
__
__
__
120 ppm H2S
_
1050 °C Flue gas temp.
32.5 °C Ambient temp.
15.2 m/s Velocity
1.2 %
Flue gas loss
0.150 %
HC
_______________________
Batch 25/2
292
193
NOx ppm SO2 ppm
%
HC
4:
Zoom
Gas
dp = 0
4 user defined function buttons
Set date/time
10.9
S Change date
E View
%
Instrument
Service
ppm VT
86
Fuel oil
Fuel
23.6
n
°C
260
% AT
ESC
°C
OK
Easy to follow menu guide and operation
Industrial probe
Standard flue
gas probes
Pitot tube
Suitable flue gas and velocity
probes as well as temperature
probes are available for a wide
range of applications.
Flue gas probes up to 4 m long,
1800 °C are available, heated or
non-heated (to avoid
condensate).
Temperature probes are also
available for surface, gas and
liquid measurements.
Velocity probe options include
vane and hot wire/hot bulb
probes which can be connected
to the control unit testo 350-XL in
addition to Pitot tubes.
Additional information at
www.testo.com
23
testo 350-S/-XL
Gas sampling probes
Sampling probes have to endure
extreme conditions when
measuring flue gases for example:
•
•
•
•
High temperatures
Corrosive condensate
Dust
Mechanical loads.
The selection of the right probe is
critical for accurate and
consistent measurements.
Because the sampling locations
are often different, it´s beneficial to
have a standard probe designed
for a wide variety of applications.
In addition to the standard
sampling probes, Testo also offers
probe systems for specific
industrial applications.
Standard sampling probes
Industrial probes – Options to fit every application
Standard sampling probes
335/700 mm long
The standard sampling probe is available
in lengths of 335 mm and 700 mm and
for different temperature ranges. The
outer pipe with a sintered filter is used
for dusty flue gases. The hose has a
standard length of 2.2 m (5 m optional).
Ø 8 mm
Tmax. +500/+1000 °C
Material: probe pipe Tmax +500 °C:
Stainless steel 1.4361
Material: probe pipe Tmax +1000 °C:
Stainless steel 1.4841
Option: Outer pipe with filter for dusty flue gases
Hose length:
Standard 2.2 m / 5 m optional
Ø 10 mm
Tmax 1000 °C
Pore size: 3 µm / Material of probe pipe: Stainless steel 1.4841
Standard probes, 335 mm long
Standard probes, 700 mm long
Part no.
Basic flue gas probe, 700 mm immersion depth, with probe stop, NiCr-Ni (TI) 0600 7452
T/C, probe shaft: stainless steel 1.4361 (Tmax 500° C), 2.2 m hose, robust
plug-in coupling
Basic flue gas probe, 335 mm immersion depth, with probe stop, NiCr-Ni (TI) 0600 7451
T/C, probe shaft: stainless steel 1.4361 (Tmax 500° C), 2.2 m hose, robust
plug-in coupling
Options
Heat-resistant probe shaft with pre-filter, Tmax. +1000 °C, 335 mm long, for
dusty flue gases, 3 µm pore size, probe shaft: stainless steel 1.4841
or
Heat-resistant probe shaft without pre-filter (material: stainless steel
1.4841), Tmax + 1000 °C, with heat-resistant plate, 335 mm long
1) Special
hose for NO2/SO2 measurements, 2.2 m long
hose for NO2/SO2 measurements, 5 m long
Hose, 5 m long (not for SO2 measurements)
1) Use outer pipe with filter for dusty flue gases.
Accessories
Options
Part no.
0440 7435
Heat-resistant probe shaft with pre-filter, Tmax. +1000°C, 700 mm long, for
dusty flue gases, 3 µm pore size, probe shaft: stainless steel 1.4841
or
Heat-resistant probe shaft without pre-filter (material: stainless steel
1.4841), Tmax +1000 °C, with heat-resistant plate, 700 mm long
0440 7437
Hose, 5 m long
hose for NO2/SO2 measurements, 2.2 m long
1) Special hose for NO2/SO2 measurements, 5 m long
1) Use outer pipe with filter for dusty flue gases.
0440 7442
0440 7445
0440 7443
1) Special
1) Special
TÜV-tested gas sampling probes (specially for trade)
TÜV approved flue gas probe, 335 mm immersion depth,
up to +500°C, corresponding to the latest instrument test
guidelines, also for atmospheric gas systems, 2.2 m hose
24
Additional information at
Part no.
0440 7436
0440 7438
0440 7444
0440 7442
0440 7446
Part no.
0554 3372
Spare sintered filter (2 off)
TÜV approved flue gas probe, 180 mm immersion depth,
up to +500°C, corr. to the latest instr. test guidelines, also
for meas. on atmospheric gas systems, 2.2 m hose
Part no.
Part no.
180 mm
0600 9556
Ø 8 mm
335 mm
0600 9557
Ø 8 mm
www.testo.com
testo 350-S/-XL
Robust sampling probes for industrial
applications
This is a modular, portable probe
system. The basic part of the system is
the heated handle or non-heated
adapter to which the sampling hoses are
attached.
A thermocouple, connected to testo 350
M/XL, is used for simultaneous
temperature measurements. Using
extension pipes (up to max. 3 m) the
probe can be used in large flue gas
ducts. A preliminary filter is screwed on
to protect the probe if used in dusty
gases.
Industrial probes – Options to fit every application
The heated probe (Ex. 1) is used for
moist flue gases to eliminate false
readings caused by the absorption of
NO2 and SO2. The probes are attached
to the flue gas duct using the mounting
flange.
Non-heated probe pipes are used for
flue gases up to 1200 °C (Ex. 2). The
non-heated adapter can be used instead
of a heated handle to measure O2, CO
and NO or dry flue gases.
Example 1, Up to 600 °C
Thermocouple
Mounting flange
Extension pipe
Heated handle
Ceramic
preliminary
filter
Heated sampling pipe
Gas sampling hose
Example 2, Up to 1200 °C
Ceramic sampling pipes (Ex. 3) which
can withstand the enormous thermal
load are used for measurements at more
than 1200 °C.
Heated handle or non-heated adapter
Ceramic preliminary filter (max.
1000 °C)
Extension pipes
Sampling probe
Example 3, Up to 1800 °C
Heated handle or non-heated adapter
Ceramic sampling pipe
Industrial probes
Heated handle, power supply 115 to 230 V, 50/60 Hz
Part no.
Adapter, non-heated
Non-heated sampling pipe to +600 °C, stainless steel 1.4571
Non-heated sampling pipe to +1200 °C, Inconel 625
Non-heated sampling pipe to +1800 °C, Al-Oxide
Connection: G1/4“
Power consumption: 200 watts; Temp. gas path: > 180 °C; Ready to operate: after approx. 20 min;
Length of mains cable: 3 m; Protection class: IP54; Ambient temp.: -20 to +50 °C; gas inlet: G1/4“; gas
outlet: M 10x1 outer thread; weight: 1.7 kg
Ambient temp.: -20 to +50 °C; Protection class: IP54; Gas
inlet: G1/4“; Gas outlet: M 10x1 outer thread; Weight: 0.4
kg
1000 mm
Weight 0.4 kg
Ø 20 mm
Ø 20 mm
1000 mm
Ø 25 mm
1000 mm
Ø 20 mm
0600 7801
Weight 0.4 kg
Ø 12 mm
Heated sampling pipe, power supply 230 V / 50 Hz, stainless steel 1.4571
Extension pipe to +600 °C, stainless steel 1.4571
Extension pipe to +1200 °C, Inconel 625
Preliminary filter for dusty flue gases, ceramic
Preliminary filter can only be mounted on extension pipe 0600 7802 or 0600 7804.
0600 7911
0600 7803
0600 7805
Ø 12 mm
1000 mm
Connection: G1/4“
0600 7920
Ø 12 mm
50 mm
Heating: > +180 °C; power consumption: 650 watts;
Connection: electr. connection to heated handle, connection
adapter with thread connection/screw socket G1/4“; Max. flue
gas temp.: +600 °C
0600 7820
Connection: Thread screw/screw socket G1/4“; Weight:
0.45 kg
0600 7802
0600 7804
0554 0710
Dust load: max. 20 g / m3; filter fineness: 20 µm;
Temperature: max. 1000 °C; Material: ceramic;
Connection: G1/4“ thread nipple; Weight: 0.2 kg
Ø 20 mm
Thermocouple, NiCr-Ni, -200 to +1000 °C, Inconel 625, 1.2 m long
Thermocouple, NiCr-Ni, -200 to +1000 °C, Inconel 625, 2.2 m long
Thermocouple, NiCr-Ni, -200 to +1000 °C, Inconel 625, 3.2 m long
Gas sampling hose, 4 m, standard version
Ø 4 mm
4m
Special sampling hose for accurate NO2/SO2 measurements, 4 m long
4m
Mounting flange, stainless steel 1.4571, adjustable quick-action fitting suitable for all
sampling/extension pipes
Weight: 0.4 kg
Hose material inside: PFFE hose with 2 mm inner diameter (lowest
absorption, self-cleaning effect); Material outside: rubber; length: 4.0
m; Weight: 0.45 kg
After approx. 20 min
3 m long
IP54
-20 to +50 °C
G1/4“
M 10x1 outer thread
1.7 kg
Adapter,
non-heated
Part no.:
Ambient temp.:
Protection class:
Gas input:
Gas output::
Weight:
0600 7911
-20 to +50 °C
IP54
G1/4“
M 10x1 outer thread
0.4 kg
0600 7920
115 to 230 V
50/60 Hz
200 watts
> 180 °C
Non-heated sampling pipes
Dimensions:
Length: 1 m, Ø 12 mm
Connection:
G1/4“
Weight:
0.4 kg
Sampling pipe up to +600 °C
Part no.:
0600 7801
Material:
Stainless steel 1.4571
Sampling pipe up to +1200 °C
Part no.:
0600 7803
Material:
Inconel 625
Sampling pipe up to +1800 °C
Part no.:
0600 7805
Material:
Al-Oxyd
Heated sampling pipe
Part no.:
Dim.:
Material:
Heating:
Power
supply:
Power required:
Connection:
Max. flue gas
temperature:
Extension pipe
Dimensions:
Connection:
Weight:
Extension pipe
Part no.:
Additional information at
0600 7820 (230 V)
Length: 1 m, Ø 25 mm
Stainless steel 1.4571
> +180 °C
230 V / 50 Hz
650 watts
• Electr. connection to
heated handle
• Connection adapter with
thread screw/
screw socket G1/4“
+600 °C
L = 1 m, Ø 12 mm (pipe)
Screw socket/
thread screw G1/4“
0.45 kg
Up to +600 °C
0600 7802
0430 0066
0430 0067
0554 3382
0554 3384
0554 0760
130
mm
Ø 160 mm
Transport case for industry probes
Transport case for industrial probes, aluminium, space for: handle, probes, flange and accessories
Heated handle
Part no.:
Power:
supply:
Power
required:
Temp. gas path:
Ready to
operate:
Mains cable:
Protection class:
Ambient temp.:
Gas input:
Gas output:
Weight:
0430 0065
Connection: To analyser via 4 m connection cable with 8
pin plug; Weight: 0.15 kg.
The length depends on the number of sampling and
extension pipes used.
Part no.
0516 7900
Material:
Extension pipe
Part no..:
Material:
Stainless steel 1.4571
Up to +1200 °C
0600 7804
Inconel 625
Preliminary filter for dusty flue gases
Part no.:
0554 0710
Dust load:
max. 20 g / m3
Filter fineness:
20 µm
Temperature:
max. 1000 °C
Dimensions:
50 mm, Ø 20 mm
Material:
Ceramic
Connection:
G1/4“ threaded nipple
Weight:
0.2 kg
Thermocouple
Part no.:
Sensor:
Meas. range:
Lengths:
Diameter:
Material:
Connection:
Weight:
0430 0065 (1.2 m long)
0430 0066 (2.2 m long)
0430 0067 (3.2 m long)
NiCr-Ni
-200 to +1000 °C
1.2 / 2.2 / 3.2 m
4 mm
Inconel 625
to analyser via 4 m
connection cable
with 8 pin plug
0.15 kg
lyser
Part no.:
Version:
Hose material:
Length:
Weight:
Mounting flange
Part no..:
Material:
Diameter:
Connection:
0554 3382
1 Viton hose with
robust plug
Viton
4,0 m
0.4 kg
0554 0760
Stainless steel 1.4571
160 mm
Movable quick-action fitting,
suitable for all sampling
and extension pipes
Special sampling hose for accurate N02/S02
measurements for connection to testo 350 M/XL analyser
Part no.:
0554 3384
Version:
patented 1 way hose
with robust plug
Host material/Inner: PTFE hose with 2 mm inner
diameter (lowest absorption,
self-cleaning effect)
Host material/Outer: Rubber
Length:
4m
Weight:
0.45 kg
www.testo.com
Standard sampling hose for connection to testo 350 M/XL ana-
25
testo 350-S/-XL
More probes
Gas sampling probes for measurements on industrial motors
Information about instrument upgrades and prices available on request.
Part no.
Flue gas probe for industrial motors, 335 mm immersion depth, with probe stop and heat protection
plate, Tmax 1000 °C, special hose for NO 2/SO2 measurements, 2.2 m long
0600 7550
Flue gas probe for industrial motors with probe shaft prefilter, 335 mm immersion depth, with probe stop
and heat protection plate, Tmax 1000 °C, special hose for NO 2/SO2 measurements, 2.2 m long
0600 7551
Accessories for gas sampling probes for measurements on industrial engines
Zubehör
Spare sintered filter (2 off)
Part no.
0554 3372
Thermocouple for exhaust gas temperature measurement (NiCr-Ni, length 400
mm, Tmax. +1000 °C), with 2.4 m connection cable
0600 8894
Temperature
Illustration
Meas. range
Combustion air temperature probe, immersion
depth 300 mm
Accuracy
0 to +100 °C
t99
Part no.
30 s
0600 9791
300 mm
Ø 5 mm
Combustion air temperature probe, immersion
depth 190 mm
0 to +100 °C
190 mm
0600 9787
Ø 4 mm
Combustion air temperature probe, immersion
depth 60 mm
0 to +100 °C
60 mm
30 s
Mini ambient air probe, Tmax +80°C, for separate
ambient air temperature measurement
0 to +80 °C
Pipe wrap probe for pipes with diameter of up to
2", for flow/return temp. meas. in hydronic
systems
-60 to +130 °C
Class 2
5s
0600 4593
-60 to +130 °C
Class 2
5s
0602 0092
-200 to +300 °C
Class 2
3s
0604 0194
Meas. range
Other features
t90
Part no.
35 mm
15 mm
Fast-action surface probe with sprung
thermocouple strip, for measurements on floor
heating, radiators, insulations...
More probes
0600 3692
Conn.: Fixed cable
Spare meas. head for pipe wrap probe, TC Type K
150 mm
Ø 10 mm
Conn.: Plug-in head. connection cable 0430 0143 or 0430 0145 required
Illustration
Gas leak probe
0632 3330
Ambient CO probe, for detecting CO in buildings
and rooms
Fixed cable 1.5 m
Ambient CO2 probe
0 to +500 ppm CO
±5% of mv (+100.1 to +500 ppm CO)
±5 ppm CO (0 to +100 ppm CO)
0632 3331
0 to +1 Vol.
±(50 ppm CO2 ±2% of mv)(0 to +5000
ppm CO2)
±(100 ppm CO2 ±3% of mv)(+5001 to
+10000 ppm CO2)
0632 1240
±1 mV (0 to +1000 mV)
±0.01 V (0 to +10 V)
±0.04 mA (0 to +20 mA)
Plug-in head. connection cable
0430 0143 or 0430 0145 required
0554 0007
% CO2
0 to +10000 ppm
CO2
Conn.: Plug-in head. connection cable 0430 0143 or 0430 0145 required
Current/voltage cable (±1 V, ±10 V, 20 mA)
0 to +1000 mV
0 to +10 V
0 to +20 mA
20 to 20000 rpm
Mechanical rpm probe with plug-in head
Included
2 probe tips Ø 8 and Ø 12 mm
Conn.: Plug-in head. connection cable 0430 0143 or 0430 0145 required
1 hollow cone Ø 8 mm
1 surface speed disc Ø 19 mm to measure rotational speed: rpm = rotational speed in mm/s
26
0600 9797
Ø 4 mm
Additional information at
0640 0340
www.testo.com
testo 350-S/-XL
More probes
Pitot tubes for flow measurement
Illustration
Pitot tube, 350 mm long, stainless steel, for measuring
flow velocity in connection with 0638 1347/..1447
pressure probes
350 mm
Meas. range
Part no.
Oper. temp.
0 to +600 °C
0635 2145
Oper. temp.
0 to +600 °C
0635 2345
-40 to +600 °C
0635 2140
-40 to +1000 °C
0635 2042
-40 to +600 °C
0635 2240
Ø 7 mm
Pitot tube, 1000 mm long, stainless steel, measures flow
speed with pressure probes 0638 1347/..1447
1000 mm
Ø 7 mm
Pitot tube, stainless steel, 500 mm long, measures flow
speed with temperature, for pressure probes 0638
1347/..1447
500 mm
Ø 8 mm
Pitot tube, stainless steel, 750 mm long, measures flow
speed with temperature, 3x hoses (5 m long) and heat
protection plate
750 mm
Ø 8 mm
Pitot tube, stainless steel, 1000 mm, measures flow speed
with temperature, for pressure probes 0638 1347/..1447
1000 mm
Ø 8 mm
Accessories
Zubehör
Hose connection set for gas pressure measurement in heating systems, incl.
silicone hoses and T-pieces, For separate gas pressure measurement
Part no.
0554 0315
Accessories
Zubehör
Cable, 1.5 m long, connects probe with plug-in head to meas. instrument,
PUR coating material
ISO calibration certificate velocity, hot wire, vane anemometer, Pitot tube;
calibration points 1; 2; 5; 10 m/s
0520 0004
Cable, 5 m long, connects probe with plug-in head to measuring instrument, 0430 0145
PUR coating material
ISO calibration certificate/Velocity, hot wire, vane anemometer, Pitot tube;
calibration points 5; 10; 15; 20 m/s
0520 0034
Extension cable, 5 m long, between plug-in head cable and instrument, PUR
coating material
0409 0063
ISO calibration certificate/temperature, meas. instr. with surface probe;
calibration points +60°C; +120°C; +180°C
0520 0071
Part no.
0430 0143
ISO calibration certificate/CO2, CO2 probes; calibration points 0; 1000; 5000 0520 0033
ppm
Additional information at
www.testo.com
27
testo 350-S/-XL
Measurement System and Practical Accessories
testo 350-S control unit
Zubehör
Control unit displays measurement data and controls measurement system,
built-in printer, connection for Testo data bus and terminal plug included
Part no.
0563 0369
testo 350 XL control unit
Zubehör
Control unit displays measurement data and controls the measurement
system, incl. built-in printer, pressure measurement 40/200 hPa, 1 user
defined probe socket, programmable measurements and memory space for
250,000 readings, connection for Testo data bus, incl. terminal plug
Part no.
0563 0353
Additional options only for control unit testo 350 XL
Part no.
0516 0355
Wall holder for analyzer box incl. heat protection plate, can be locked
0554 0203
Protective cover for analyser box (can also be used with wall holder)
0554 0199
Carrying belt set for analyser box and control unit
0554 0434
Transport case for analyser, probes and accessories
0516 0351
Touch screen with pen (available only with original order), for easy input of
text and values
0440 0559
0554 0569
System case (aluminium), with drawer for accessories, for transport and
protection during measurement
0516 0352
Spare thermal paper for printer (6 rolls)
0515 0097
Transport case for industrial probes, aluminium; space for: handle, probes,
flange and accessories
0516 7900
Testo rechargeable battery pack NiMH for control unit, logger
0554 1084
Calculation of fuel-specific factors to accurately display calculated variables in deviating
fuels (calculation for one fuel)
0991 0030
Mains unit 230 V/ 8 V/ 1 A, for instrument (European plug)
Spare particle filter, pack of 20
0554 3381
Hose set to convey flue gas from analyzer box, 5 m long
0554 0451
Refill pack of filter pellets for CO2 absorption filter
0554 0369
testo 350 S flue gas analyzer
Zubehör
Part no.
0563 0368
testo 350-S flue gas analyser, equipped with: O2, differential pressure
measurement, 2 temperature probe sockets, testo data bus connection, builtin rechargeable battery, data logger, can be upgraded to max. 6 sensors (with
NO, NO2, CO, H2S, HC, SO2, CO2 NDIR)
A second gas sensor must be installed in testo 350-S, otherwise the
instrument is unable to function. Up to 5 additional sensors can be fitted.
ISO calibration certificate/flue gas, calibration points 2.5% O2; 100 and 1000 0520 0003
ppm CO; 800 ppm NO; 80 ppm NO2; 1000 ppm SO2
testo 454 logger and accessories
Zubehör
Part no.
0577 4540
Option: COlow sensor
Option: CO sensor
Option: CO2 sensor (infrared meas. principle, absolute pressure meas. and
CO2 absorption filter with refill pack incl.)
0440 3936
0440 3988
0440 0417
Logger, measures and saves (max. 250,000 readings), incl. 4 user defined probe sockets,
alarm output/event trigger socket, stand/wall holder
Alarm/trigger cable
0554 0012
Option: HC sensor (nonburned hydrocarbons)
Option: H2S sensor
Option: NO sensor
Option: NOlow sensor
Option: NO2 sensor
Option: SO2 sensor
Option: Peltier gas preparation with hose pump to empty condensate
automatically
0440 3929
0440 3930
0440 3935
0440 3928
0440 3926
0440 3927
0440 0355
Holding unit/Theft-proof with lock for logger wall holder
0554 1782
Power box, connected to control unit to increase operating life, for a batteryoperated measuring system
0554 1045
Desk-top power supply with international connection options
0554 1143
Fresh air valve for long-term measurement (measurement range extension
with dilution factor 5 for all sensors included)
0440 0557
Testo rechargeable battery pack NiMH for control unit, logger
Measuring range extension for CO sensor (dilution), built into analyser box, 0440 0555
selectable dilution factors: 0, 2, 5, 10, 20, 40
Event trigger socket, for starting and stopping measurement externally, built 0440 3932
into analyser box
Special gas pump for long-term measurements with extended warranty
testo 350 XL flue gas analyzer box
Zubehör
Part no.
0563 0350
testo 350 XL analyzer box, equipped with O2, CO (with switch-off and rinse
function), NO, NO2, differential pressure measurement, 2 temperature probe
sockets, gas preparation, Testo data bus adapter, automatic fresh air rinse with
valve (including measurement range extension with dilution factor 5 for all
sensors), built-in rechargeable battery, data memory, can be upgraded to max.
6 gas sensors (with H2S, HC, SO2, CO2 NDIR)
Option: COlow gas sensor
Option: CO2 sensor (infrared meas. principle, absolute pressure meas. and
CO2 absorption filter with refill pack incl.)
0440 3925
0440 0417
Option: NOlow gas sensor
Option: SO2 sensor
Option: HC sensor (nonburned hydrocarbons)
Option: H2S sensor
Measuring range extension for CO sensor (dilution), built into analyser box,
selectable dilution factors: 0, 2, 5, 10, 20, 40
0440 3934
0440 3927
0440 3929
0440 3930
0440 0555
Event trigger socket, for starting and stopping measurement externally, built
into analyser box
0440 3932
Special gas pump for long-term measurements with extended warranty
0440 0378
Information about instrument upgrades and prices available on request.
Additional information at
Analog output box, 6 channels, 4 to 20 mA, for output on an analog recorder, 0554 0845
(please also order mains unit 0554 1084)
0515 0097
Accessories for Testo data bus
Zubehör
Part no.
Mains unit (110/230 V; 50/60 Hz, 12 V, 3 A) supplies power to Testo data bus, 0554 1145
when using the Testo plug-in card
Terminal plug for Testo data bus, for loggers and special lengths
0554 0119
Connection cable, 2 m, for Testo data bus
0449 0042
Connection cable, 5 m, for Testo data bus
0449 0043
Connection cable, 20 m, for Testo data bus
0449 0044
0440 0378
(For continuous measurements >2 h measurement time, the option Peltier gas praparation 0440 0355 is
additionally recommended).
28
Transport case and accessories for analyser boxes
Zubehör
Robust protective case with trolley function for operating the testo 350 in the
case in dusty and tough surroundings
Additional cable lengths up to 1000 m on request
PC software
Zubehör
Part no.
"easyEmission" software for testo 350-S/-XL, RS232 cable for connecting
0554 3335
instrument to PC included
"easyEmission" software for testo 350 S/XL, Testo data bus controller
0554 3336
included, with USB to connect instrument to PC, cable for Testo data bus and
terminal plug
Software upgrade of "easyEmission" testo 350-S/-XL to "easyEmission" testo 0450 3334
335
Software upgrade of "easyEmission" testo 335 to "easyEmission" testo 350S/-XL
0450 3335
Multiple licence software "easyEmission" for testo 350-S/-XL
0554 3337
Accessories exhaust gas analysis instrument
Zubehör
Cable to connect measuring instrument to pulse counter for gas flow
measurement
Part no.
0554 0536
Cable with adapter for cigarette lighter and adapter for connection to testo
350-S/-XL
0554 1336
Cable with battery clamps and adapter for connection to testo 350-S/-XL
0554 1337
www.testo.com
testo 350-S/-XL
testo 350 M: Set for fast emission monitoring on industrial burners (O2, CO,
NO)
testo 350 XL: Standard set for measurements on process systems (O2, CO,
NO, NO2)
-
-
-
testo 350-S control unit (Part no. 0563 0369)
testo 350-S flue gas analyser box (Part no. 0563 0368)
Option: NO sensor (Part no. 0440 3935)
Option: CO sensor (Part no. 0440 3988)
Flue gas probe, 335 mm immersion depth, Thermocouple NiCr-Ni (TI), Hose 2.2 m (Part no. 0600
7451)
Heat-proof probe pipe, 335 mm long, Tmax. +1000°C (Part no. 0440 7437)
Connection cable, 2 m, for Testo data bus (Part no. 0449 0042)
Protective cover for analyzer box (Part no. 0554 0199)
Carrying belt set for analyser box (Part no. 0554 0434)
Transport case for analyser, probes and accessories (Part no. 0516 0351)
Spare particle filter, pack of 20 (Part no. 0554 3381)
Spare thermal paper for printer (6 rolls) (Part no. 0554 0569)
-
testo 350 XL control unit (Part no. 0563 0353)
Testo rechargeable pack for control unit (Part no. 0515 0097)
testo 350 XL flue gas analyzer box (Part no. 0563 0350)
Flue gas probe, 335 mm immersion depth, Thermocouple NiCr-Ni (TI), Hose 2.2 m (Part no. 0600
7451)
Heat-proof probe pipe, 335 mm long, Tmax. +1000°C (Part no. 0440 7437)
Special hose for NO2/SO2 measurements, 2.2 m long (Part no. 0440 7442)
Connection cable, 2 m, for Testo data bus (Part no. 0449 0042)
"easyEmission" software for testo 350 S/XL (Part no. 0554 3335)
Protective cover for analyzer box (Part no. 0554 0199)
Carrying belt set for analyser box (Part no. 0554 0434)
Transport case for analyser, probes and accessories (Part no. 0516 0351)
Spare particle filter, pack of 20 (Part no. 0554 3381)
Spare thermal paper for printer (6 rolls) (Part no. 0554 0569)
testo 350 XL: Portable measurements on motors
(O2, CO, NO, NO2)
testo 350 XL: Portable measurements on gas turbines
(O2, COlow, NOlow, NO2)
-
-
testo 350 XL control unit (Part no. 0563 0353)
Testo rechargeable pack for control unit (Part no. 0515 0097)
testo 350 XL flue gas analyzer box (Part no. 0563 0350)
Measurement range extension for CO sensor (dilution) (Part no. 0440 0555)
Flue gas probe for industrial motors (Part no. 0600 7550)
Connection cable, 5 m, for Testo data bus (Part no. 0449 0043)
"easyEmission" software for testo 350 S/XL (Part no. 0554 3335)
Protective cover for analyzer box (Part no. 0554 0199)
Carrying belt set for analyser box (Part no. 0554 0434)
System case (aluminium), incl. drawer (Part no. 0516 0352)
Spare particle filter, pack of 20 (Part no. 0554 3381)
Spare thermal paper for printer (6 rolls) (Part no. 0554 0569)
Additional information at
-
testo 350 XL control unit (Part no. 0563 0353)
Testo rechargeable pack for control unit (Part no. 0515 0097)
Touchscreen with reader (Part no. 0440 0559)
testo 350 XL flue gas analyzer box (Part no. 0563 0350)
COlow sensor, 0 to 500 ppm, built into analyser box (Part no. 0440 3925 )
NOlow sensor, 0 to 300 ppm, built-in in analyser box (Part no. 0440 3934 )
Measurement range extension for CO sensor (dilution) (Part no. 0440 0555)
Flue gas probe, 335 mm immersion depth, Thermocouple NiCr-Ni (TI), Hose 2.2 m (Part no. 0600
7451)
Heat-proof probe pipe, 335 mm long, Tmax. +1000°C (Part no. 0440 7437)
Special hose for NO2/SO2 measurements, 5 m long (Part no. 0440 7445)
Connection cable, 5 m, for Testo data bus (Part no. 0449 0043)
"easyEmission" software for testo 350 S/XL (Part no. 0554 3335)
Protective cover for analyzer box (Part no. 0554 0199)
Carrying belt set for analyser box (Part no. 0554 0434)
System case (aluminium), incl. drawer (Part no. 0516 0352)
Spare particle filter, pack of 20 (Part no. 0554 3381)
Spare thermal paper for printer (6 rolls) (Part no. 0554 0569)
www.testo.com
29
testo 350-S/-XL
Technical data
Technical Data for Control unit testo 350-S/-XL and testo 454 logger box
testo 350-S control unit
testo 350 XL control unit
Logger, measures and saves
readings
Analog output box (mA out)
Oper. temp.
-5 to +45 °C
-5 to +45 °C
-10 to +50 °C
-10 to +50 °C
Storage temp.
-20 to +50 °C
-20 to +50 °C
-25 to +60 °C
-25 to +60 °C
Battery type
4 AA batteries
4 AA batteries
Alkali manganese
–
Battery life
8h
8h
24 h
–
Memory
–
250000 readings
250000 readings
–
Weight
850 g
850 g
450 g
305 g
Dimensions
252 x 115 x 58 mm
252 x 115 x 58 mm
200 x 89 x 37 mm
200 x 89 x 37 mm
Warranty
2 years
2 years
3 years
3 years
Technical data control unit testo 350-XL and testo 454 logger box
Probe type
Vane
Thermal
Testo humid. sensor, cap.
Pressure
Meas. range
0 to +60 m/s
0 to +20 m/s
0 to +100 %RH
10 to 30000 hPa
Accuracy
±1 digit
See probe data for system accuracy
±0.01 m/s (0 to +1.99 m/s)
±0.02 m/s (+2 to +4.99 m/s)
±0.04 m/s (+5 to +20 m/s)
See probe data
Probe 0638 1345
Probe 0638 1445
Probe 0638 1545
Probe 0638 1645
±0.1% of m.v.
Resolution
0.01 m/s (for Ø 60/100 mm),
0.1 m/s (for remaining probes)
0.01 m/s (0 to +20 m/s)
0.1 %RH (0 to +100 %RH)
0.001 hPa (probe 0638 1345)
0.001 hPa (probe 0638 1445)
0.01 hPa (probe 0638 1545)
Probe type
Pt100
Type K (NiCr-Ni)
Type S (Pt10Rh-Pt)
Type J (Fe-CuNi)
Type T (Cu-CuNi)
Meas. range
-200 to +800 °C
-200 to +1370 °C
0 to +1760 °C
-200 to +1000 °C
-40 to +350 °C
Accuracy
±1 digit
±0.1 °C (-49.9 to +99.9 °C)
±0.4 °C (-99.9 to -50 °C)
±0.4 °C (+100 to +199.9 °C)
±1 °C (-200 to -100 °C)
±1 °C (+200 to +800 °C)
±0.4 °C (-100 to +200 °C)
±1 °C (-200 to -100.1 °C)
±1 °C (+200.1 to +1370 °C)
±1 °C (0 to +1760 °C)
±0.4 °C (-150 to +150 °C)
±1 °C (-200 to -150.1 °C)
±1 °C (+150.1 to +199.9 °C)
±0.4 °C (-40 to +200 °C)
±1 °C (+200.1 to +350 °C)
Resolution
0.001 °C (-9.999 to +300 °C)
0.1 °C (-200 to -100 °C)
0.1 °C (+301 to +800 °C)
0.1 °C (-200 to +1370 °C)
1 °C (0 to +1760 °C)
0.1 °C (-200 to +1000 °C)
0.1 °C (-40 to +350 °C)
Probe type
NTC
CO probe
CO2 probe
CO2 probe
Meas. range
-40 to +150 °C
0 to +500 ppm CO
0 to +1 Vol. % CO2
0 to +10000 ppm CO2
Accuracy
±0.2 °C (-10 to +50 °C)
±0.4 °C (-40 to -11 °C)
±0.4 °C (+51 to +150 °C)
±5% of mv (0 to +500 ppm CO)
See probe data
See probe data
±1 digit
Resolution
0.1 °C (-40 to +150 °C)
Mechanical
Current/voltage measurement
Current/voltage measurement
Control unit, integ. press. sensor
Meas. range
20 to 20000 rpm
0 to +20 mA
0 to +10 V
-200 to +200 hPa
-40 to +40 hPa
Accuracy
±1 digit
±0.04 mA (0 to +20 mA)
±0.01 V (0 to +10 V)
±1.5% of mv (-50 to -200 hPa)
±1.5% of mv (+50 to +200 hPa)
±0.5 hPa (-49.9 to +49.9 hPa)
±1.5% of mv (-3 to -40 hPa)
±1.5% of mv (+3 to +40 hPa)
±0.03 hPa (-2.99 to +2.99 hPa)
1 rpm
0.01 mA (0 to+20 mA)
0.01 V (0 to +10 V)
0.1 hPa (-200 to +200 hPa)
0.01 hPa (-40 to +40 hPa)
±1 digit
Resolution
30
Additional information at
www.testo.com
testo 350-S/-XL
Technical data
Technical data/testo analyser box, testo 350-S XL
Parameters
°C measurement
(Type K NiCr-Ni)
O2 measurement CO measurement COlow meas. (H2
(H2 compensated) compensated)
Meas. range
-40 to +1200 °C
0 to +25 Vol.
Accuracy
±1 digit
±0.5% of mv
(+100 to +1200
°C)
±0.5 °C (-40 to
+99.9 °C)
Resolution
0.1 °C (-40 to
+1200 °C)
NO2 measurement SO2 measurement
0 to +10000 ppm
CO
0 to +500 ppm
CO
0 to CO2 max Vol.
% CO2
0 to +3000 ppm
NO
0 to +300 ppm
NO
0 to +500 ppm
±0.8% of fsv (0 to
+25 Vol. % O2)
±5% of mv (+200 to
+2000 ppm CO)
±10% of mv (+2001
to +10000 ppm CO)
±10 ppm CO (0 to
+199 ppm CO)
±5% of mv (+40
to +500 ppm CO)
±2 ppm CO (0 to
+39.9 ppm CO)
Calculated from
O2
±5% of mv (+100 to
+1999.9 ppm NO)
±10% of mv (+2000
to +3000 ppm NO)
±5 ppm NO (0 to +99
ppm NO)
±5% of mv (+40
to +300 ppm NO)
±2 ppm NO (0 to
+39.9 ppm NO)
±5% of mv (+100
to +500 ppm NO2)
±5 ppm NO2 (0 to
+99.9 ppm NO2)
±5% of mv (+100 to
+2000 ppm SO2)
±10% of mv (+2001 to
+5000 ppm SO2)
±5 ppm SO2 (0 to +99
ppm SO2)
0.01 Vol. % O2 (0
to +25 Vol. % O2)
1 ppm CO (0 to
+10000 ppm CO)
0.1 ppm CO (0 to
+500 ppm CO)
0.01 Vol. % CO2
1 ppm NO (0 to
+3000 ppm NO)
0.1 ppm NO (0 to
+300 ppm NO)
0.1 ppm NO2 (0 to
+500 ppm NO2)
1 ppm SO2 (0 to
+5000 ppm SO2)
Reaction time
20 s
40 s
40 s
20 s
30 s
30 s
40 s
30 s
Reaction type
Parameters
t95
t90
t90
t95
t90
t90
t90
t90
Meas. range
Efficiency
0 to +120 %
% O2
CO2 measurement NO measurement NOlow
measurement
Flue gas loss
Differential
pressure 1
-20 to +99.9 %
qA
Accuracy
±1 digit
Differential
pressure 2
Velocity
-200 to +200 hPa
-40 to +40 hPa
±1.5% of mv (-50
to -200 hPa)
±1.5% of mv (+50
to +200 hPa)
±0.5 hPa (-49.9
to +49.9 hPa)
±1.5% of mv (-40
to -3 hPa)
±1.5% of mv (+3
to +40 hPa)
±0.03 hPa (-2.99
to +2.99 hPa)
0.1 hPa (-200 to
+200 hPa)
0.01 hPa (-40 to
+40 hPa)
CO2 meas. (IR)
0 to +40 m/s
0 to +50 Vol. %
CO2
0 to +300 ppm
H2S
±0.3 Vol. % CO2
±5% of mv (+40 to +300
+ 1% of mv (0 to 25 Vol. %
ppm)
CO2)
±2 ppm (0 to +39.9 ppm)
+ 1.5% of mv (>25 to 50
Vol. % CO2)
Reaction time
<10 s
35 s
Reaction type
t90
t90
0.1 % qA (-20 to
+99.9 % qA)
Measurement range extension
Single dilution with selectable dilution factor (option)
CO measurement (H2 Meas. range
depending on factor selected
compensated)
Accuracy
±2 % of mv (additional error)
COlow meas. (H2
Resolution
1 ppm or 0.1 ppm at COlow
compensated)
Dilution of all sensors by factor 5 (standard testo 350 XL)
O2 measurement
Reading is not shown in display
HC measurement
Reading is not shown in display
CO2(IR) meas.
Reading is not shown in display
CO measurement (H2
compensated)
Meas. range
Accuracy
COlow meas. (H2
compensated)
NO measurement
2500 to 50000 ppm
±5 % of mv (additional error)
Pressure range -150 to 0 mbar at probe tip
Resolution
Meas. range
Accuracy
1 ppm
500 to 2500 ppm
Resolution
Meas. range
Accuracy
0.1 ppm
1500 to 15000 ppm
±5 % of mv (additional error)
Pressure range -100 to 0 mbar at probe tip
±5 % of mv (additional error)
Pressure range -100 to 0 mbar at probe tip
NOlow measurement
Resolution
Meas. range
Accuracy
1 ppm
300 to 1500 ppm
NO2 measurement
Resolution
Meas. range
Accuracy
0.1 ppm
500 to 2500 ppm
SO2 measurement
Resolution
Meas. range
Accuracy
0.1 ppm
500 to 25000 ppm
H2S measurement
Resolution
Meas. range
Accuracy
1 ppm
200 to 1500 ppm
Resolution
0.1 ppm
±5 % of mv (additional error)
Pressure range -150 to 0 mbar at probe tip
±5 % of mv (additional error)
Pressure range -50 to 0 mbar at probe tip)
±5 % of mv (additional error)
Pressure range -100 to 0 mbar at probe tip
±5 % of mv (additional error)
Pressure range -100 to 0 mbar at probe tip
Additional information at
SO2
±0.5 Vol. % CO2
0.1 ppm (0 to +300 ppm)
0.1 % (0 to +120
%)
0 to +5000 ppm
H2S measurement
0.01 Vol. % CO2
(0 to 25 Vol. % CO2)
0.1 Vol. % CO2
(>25 Vol. % CO2)
Resolution
NO2
0.1 m/s (0 to +40
m/s)
Technical data for HC gas sensor
Methane
Propane
Meas. range ¹
100 to 40,000 ppm
100 to 21,000 ppm
100 to 18,000 ppm
Accuracy
less than 400 ppm (100 to
4000 ppm less than 10 % of
m.v. (greater than 4000 ppm)
less than 400 ppm (100 to
4000 ppm less than 10 % of
m.v. (greater than 4000 ppm)
less than 400 ppm (100 to 4000
ppm less than 10 % of m.v.
(greater than 4000 ppm)
Resolution
10 ppm
10 ppm
10 ppm
Min. 02 req. in flue
gas
2% + (2 x methane
reading)
2% + (5 x propane
reading)
2% + (6.5 x butane reading)
Reaction time t90
less than 40 s
less than 40 s
less than 40 s
Response factor ²
1
1.5
2
Parameter
Butane
¹ Lower explosion limit must be adhered to.
² The HC gas sensor is adjusted to methane in the factory. It can be adjusted to another gas by the user.
Additional Technical data
Dimensions: 395 x 275 x 95 mm
Weight: 3200 g
Storage temperature: -20 to +50 °C
Operating temperature: -5 to +45 °C
Housing material: ABS
Memory: 250 000 readings
Power supply: Via built-in mains unit (90 V to 260 V,
47 to 63 Hz) or exchangeable rechargeable batteries
Electrial power consumption: 0.5 A (110 V AC), 0.3 A
(230 V AC)
Dewpoint calculation: 0 to 99 °C td
Maximum positive pressure/flue gas: 50 hPa (500 mm
water column)
Maximum negative pressure: 200 hPa (2000 mm
water column)
Pump flow: 1 l/min. with flow monitoring
Max. dust load: 20 g/m³ dust in flue gas
Max. humidity load: +70 °C
Dewpoint temperature at sample gas inlet of analyzer
box
Trigger input: Voltage 5 to 12 Volt (rising or falling
edge)
Pulse width > 1 s
Load: 5 V/max, 5 mA, 12 V/max. 40 mA
Warranty: Analyzers 2 years (excluding working parts,
e.g. gas sensors...); CO/NO/NO2/SO2/H2C/HC 1 year;
O2 gas sensor 1 1/2 years; CO2 IR gas sensor 2 years,
special gas pump for long term measurements 2 years
www.testo.com
31
31
Download PDF