HPE FlexFabric 12900 Switch Series

QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
HPE FlexFabric 12900 Switch Series
Models
HPE FlexFabric 12916E Switch Chassis
HPE FlexFabric 12908E Switch Chassis
HPE FlexFabric 12904E Switch Chassis
HPE FlexFabric 12916 Switch AC Chassis
HPE FlexFabric 12910 Switch AC Chassis
JH103A
JH255A
JH262A
JG632A
JG619A
Key features
•
•
•
•
•
Nonblocking, lossless Clos architecture
VxLAN, IRF, and TRILL support for virtualized and cloud deployments
High GbE, 10GbE, 40GbE, and 100GbE density across 46 Tb/s switch fabric
Enhanced modularity with control and data plane separation
SDN-enabled with OpenFlow1.3 support
Product overview
The HPE FlexFabric 12900 Switch Series is a next-generation modular data center core switch designed to support virtualized data
centers and the evolving needs of private and public cloud deployments.
The FlexFabric 12900 switch delivers unprecedented levels of performance, buffering, scale, and availability with high-density GbE,
Page 1
QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
10GbE, 40GbE and 100GbE. The HPE FlexFabric 12900 Switch Series includes 16-, 10-, 8- and 4-slot chassis.
Software-defined networking (SDN) enabled with OpenFlow 1.3, the switch supports full Layer 2 and 3 features, including advanced
features such as Virtual Extensible LAN (VxLAN), TRansparent Interconnection of Lots of Links (TRILL) and Intelligent Resilient
Fabric (IRF), which provide the ability to build large, resilient switching fabrics. The HPE FlexFabric 12900 Switch Series also
supports fully redundant and hot-swappable components to complement its other enterprise-class capabilities.
Features and benefits
Product architecture
•
•
•
•
•
Modern scalable system architecture
provides nonblocking, lossless Clos architecture with VOQs and large buffers with the flexibility and scalability for future
growth
Distributed architecture with separation of data and control planes
delivers enhanced fault tolerance and facilitates continuous operation and zero service disruption during planned or
unplanned control-plane events
Advanced Comware modular operating system
brings native high-stability, independent process monitoring, and restart through the modular design and multiple
processes of Hewlett Packard Enterprise Comware v7 software; supports enhanced serviceability functions
In-Service Software Upgrade (ISSU)
provides IRF based upgrade for seamless maintenance with minimal disruption
Multitenant Device Context (MDC)
virtualizes a physical switch into multiple logical devices, with each logical switch having its own processes, configuration,
and administration
Performance
•
•
•
High-performance fully distributed architecture
delivers up to 46 Tb/s switching capacity and 28.8 Bpps throughput with nonblocking wirespeed performance
High-density 1, 10, 40 and 100GbE interface connectivity
offers up to 16 interface module slots to scale up to 768 1/10GbE, 576 40GbE, 128 100GbE ports or a combination
Distributed scalable fabric architecture
offers up to six fabric modules to deliver more than 2 Tb per slot bandwidth
Data center optimized
•
•
•
•
•
Virtual Extensible LAN (VxLAN)
provides wire-rate support for seamless Layer 2 connectivity across Layer 3 networks enabling virtual machine mobility
and cloud deployments
Scalable Layer 2 fabrics
builds flexible, resilient, and scalable Layer 2 fabrics with TRILL and Hewlett Packard Enterprise IRF
Hewlett Packard Enterprise Ethernet Virtual Interconnect (EVI)
is an Hewlett Packard Enterprise Virtual Application Network innovation that provides a Layer 2 extension across the data
center to simplify the interconnectivity of geographically disperse data centers
Edge Virtual Bridging (EVB) with Virtual Ethernet Port Aggregator (VEPA)
provides connectivity into the virtualization-ready data center environment
Data Center Bridging (DCB) protocols
provides support for IEEE 802.1Qaz Data Center Bridging Exchange (DCBX), Enhanced Transmission Selection (ETS), and
Page 2
QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
•
•
IEEE 802.1Qbb Priority Flow Control (PFC) for converged fabrics
Fibre Channel over Ethernet (FCoE) features
deliver support for FCoE, including expansion, fabric, trunk VF and N ports, and aggregation of E-port and N-port
virtualization
Front-to-back airflow design
to accommodate deployment in data centers utilizing hot-cold aisles
Resiliency and high availability
•
•
•
•
•
•
•
•
•
•
Intelligent Resilient Fabric (IRF)
creates virtual resilient switching fabrics, where two or more switches perform as a single L2 switch and L3 router; switches
do not have to be co-located and can be part of a disaster-recovery system; servers or switches can be attached using
standard LACP for automatic load balancing and high availability; can eliminate the need for complex protocols like
Spanning Tree Protocol, Equal-Cost Multipath (ECMP), or VRRP, thereby simplifying network operation
Redundant/load-sharing fabrics, management, fan assemblies, and power supplies
increase total performance and power availability while providing hitless, stateful failover
Hot-swappable modules
allows replacement of modules without any impact on other modules
Graceful restart
allows routers to indicate to others their capability to maintain a routing table during a temporary shutdown, which
significantly reduces convergence times upon recovery; supports OSPF, BGP, and IS-IS
Virtual Router Redundancy Protocol (VRRP)
allows groups of two routers to dynamically back each other up to create highly available routed environments
Device Link Detection Protocol (DLDP)
monitors link connectivity and shuts down ports at both ends if unidirectional traffic is detected, preventing loops in STPbased networks
Hitless patch upgrades
allows patches and new service features to be installed without restarting the equipment, increasing network uptime and
facilitating maintenance
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
supports up to 1024 trunk groups and up to 16 members per trunk; supports static or dynamic groups and a userselectable hashing algorithm
Passive design system
delivers increased system reliability as the backplane has no active components
Ultrafast protocol convergence (subsecond) with standard-based failure detection—Bidirectional Forwarding
Detection (BFD)
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and
IRF
Layer 2 switching
•
•
•
•
VLAN
supports up to 4,094 port-based or IEEE 802.1Q-based VLANs
Bridge Protocol Data Unit (BPDU) tunneling
transmits Spanning Tree Protocol BPDUs transparently, allowing correct tree calculations across service providers, WANs,
or MANs
Multiple VLAN Registration Protocol (MVRP)
helps to maintain VLAN configuration dynamically based on current network configurations
Port mirroring
Page 3
QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
•
•
•
•
duplicates port traffic (ingress and egress) to a local or remote monitoring port; supports four mirroring groups, with an
unlimited number of ports per group
Port isolation
increases security by isolating ports within a VLAN while still allowing them to communicate with other VLANs
Internet Group Management Protocol (IGMP) and Multicast Listener Discovery (MLD) protocol snooping
controls and manages the flooding of multicast packets in a Layer 2 network
Spanning Tree Protocol (STP)
supports standard IEEE 802.1D STP, IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) for faster convergence, and IEEE
802.1s Multiple Spanning Tree Protocol (MSTP)
IEEE 802.1ad QinQ and selective QinQ
increase the scalability of an Ethernet network by providing a hierarchical structure; connect multiple LANs on a highspeedcampus or metro network
Layer 3 routing
•
•
•
•
•
•
•
•
•
•
•
•
•
Open shortest path first (OSPF)
delivers faster convergence; uses this link-state routing Interior Gateway Protocol (IGP), which supports ECMP, NSSA, and
MD5 authentication for increased security and graceful restart for faster failure recovery
Intermediate system to intermediate system (IS-IS)
uses a path vector Interior Gateway Protocol (IGP), which is defined by the ISO organization for IS-IS routing and extended
by IETF RFC 1195 to operate in both TCP/IP and the OSI reference model (Integrated IS-IS)
Border Gateway Protocol 4 (BGP-4)
delivers an implementation of the Exterior Gateway Protocol (EGP) utilizing path vectors; uses TCP for enhanced
reliability for the route discovery process; reduces bandwidth consumption by advertising only incremental updates;
supports extensive policies for increased flexibility; scales to very large network
Multiprotocol Label Switching (MPLS)
uses BGP to advertise routes across Label Switched Paths (LSPs), but uses simple labels to forward packets from any
Layer 2 or Layer 3 protocol, which reduces complexity and increases performance; supports graceful restart for reduced
failure impact; supports LSP tunneling and multilevel stacks
Dual IP stack
maintains separate stacks for IPv4 and IPv6 to ease the transition from an IPv4-only network to an IPv6-only network
desig
Equal-Cost Multipath (ECMP)
enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidt
Policy-based routing
makes routing decisions based on policies set by the network administrator
Static IPv4 routing
provides simple manually configured IPv4 routing
Routing Information Protocol (RIP)
uses a distance vector algorithm with UDP packets for route determination; supports RIPv1 and RIPv2 routing; includes
loop protection
IP performance optimization
provides a set of tools to improve the performance of IPv4 networks; includes directed broadcasts, customization of TCP
parameters, support of ICNP error packets, and extensive display capabilities
Unicast Reverse Path Forwarding (uRPF)
limits erroneous or malicious traffic in accordance with RFC 3074
Static IPv6 routing
provides simple manually configured IPv6 routing
Routing Information Protocol next generation (RIPng)
Page 4
QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
•
•
•
•
•
•
•
extends RIPv2 to support IPv6 addressing
OSPFv3
provides OSPF support for IPv
IS-IS for IPv6
extends IS-IS to support IPv6 addressing
BGP+
extends BGP-4 to support Multiprotocol BGP (MBGP), including support for IPv6 addressing
Multiprotocol Label Switching (MPLS) Layer 3 VPN
allows Layer 3 VPNs across a provider network; uses MP-BGP to establish private routes for increased security; supports
RFC 2547bis multiple autonomous system VPNs for added flexibility
Multiprotocol Label Switching (MPLS) Layer 2 VPN
establishes simple Layer 2 point-to-point VPNs across a provider network using only MPLS Label Distribution Protocol
(LDP); requires no routing and therefore decreases complexity, increases performance, and allows VPNs of non-routable
protocols; uses no routing information for increased security; supports Circuit Cross Connect (CCC), Static Virtual Circuits
(SVCs), Martini draft, and Kompella-draft technologies
Virtual Private LAN Service (VPLS)
establishes point-to-multipoint Layer 2 VPNs across a provider network
IPv6 tunneling
provides an important element for the transition from IPv4 to IPv6; allows IPv6 packets to traverse IPv4-only networks by
encapsulating the IPv6 packet into a standard IPv4 packet; supports manually configured, 6to4, Intra-Site Automatic
Tunnel Addressing Protocol (ISATAP) tunnels, and IPv6 on VPN to Provider Edge (6VPE) router tunnel
Quality of Service (QoS)
•
•
•
•
•
IEEE 802.1p prioritization
delivers data to devices based on the priority and type of traffic
Flexible classification
creates traffic classes based on access control lists (ACLs), IEEE 802.1p precedence, IP, and DSCP or Type of Service (ToS)
precedence; supports filter, redirect, mirror, remark, and logging
Bandwidth shaping
− Port-based rate limiting
provides per-port ingress-/egress-enforced increased bandwidth
− Classifier-based rate limiting
uses an access control list (ACL) to enforce increased bandwidth for ingress traffic on each port
− Reduced bandwidth
provides per-port, per-queue egress-based reduced bandwidth
Broad QoS feature set
provides support for Strict Priority Queuing (SP), Weighted Fair Queuing (WFQ), Weighted Deficit Round Robin(WDRR),
SP+WDRR together, configurable buffers, Explicit Congestion Notification (ECN), and Weighted Random Early Detection
(WRED)
Traffic policing
supports Committed Access Rate (CAR) and line rate
Layer 3 services
•
Address Resolution Protocol (ARP)
determines the MAC address of another IP host in the same subnet; supports static ARPs; gratuitous ARP allows detection
of duplicate IP addresses; proxy ARP allows normal ARP operation between subnets or when subnets are separated by a
Layer 2 network
Page 5
QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
•
•
User Datagram Protocol (UDP) helper
redirects UDP broadcasts to specific IP subnets to prevent server spoofing
Dynamic Host Configuration Protocol (DHCP)
simplifies the management of large IP networks and supports client and server; DHCP Relay enables DHCP operation
across subnets
Management
•
•
•
•
•
•
•
•
•
•
Management interface control
enables or disables each of the following interfaces depending on security preferences: console port, Telnet port, or reset
button
Industry-standard CLI with a hierarchical structure
reduces training time and expenses, and increases productivity in multivendor installations
SNMPv1, v2, and v3
provide complete support of SNMP; provide full support of industry-standard Management Information Base (MIB) plus
private extensions; SNMPv3 supports increased security using encryption
sFlow (RFC 3176)
provides scalable ASIC-based wirespeed network monitoring and accounting with no impact on network performance; this
allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and
real-time network monitoring purposes
Remote monitoring (RMON)
uses standard SNMP to monitor essential network functions; supports events, alarm, history, and statistics group plus a
private alarm extension group
Debug and sampler utility
supports ping and traceroute for both IPv4 and IPv6
Network Time Protocol (NTP)
synchronizes timekeeping among distributed time servers and clients; keeps timekeeping consistent among all clockdependent devices within the network so that the devices can provide diverse applications based on the consistent time
Network Quality Analyzer (NQA)
analyzes network performance and service quality by sending test packets, and provides network performance and service
quality parameters such as jitter, TCP, or FTP connection delays and file transfer rates; allows a network manager to
determine overall network performance and to diagnose and locate network congestion points or failures
Information center
provides a central repository for system and network information; aggregates all logs, traps, and debugging information
generated by the system and maintains them in order of severity; outputs the network information to multiple channels
based on user-defined rules
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
advertises and receives management information from adjacent devices on a network, facilitating easy mapping by
network management applications
Connectivity
•
•
•
Jumbo frames
allows high-performance backups and disaster-recovery systems with a maximum frame size of 9K bytes
Loopback
supports internal loopback testing for maintenance purposes and an increase in availability; loopback detection protects
against incorrect cabling or network configurations and can be enabled on a per-port or per-VLAN basis for added
flexibility
Ethernet operations, administration and maintenance (OAM)
Page 6
QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
•
•
•
detects data link layer problems that occurred in the "last mile" using the IEEE 802.3ah OAM standard; monitors the status
of the link between two devices
Monitor link
collects statistics on performance and errors on physical links, increasing system availability
Packet storm protection
protects against unknown broadcast, unknown multicast, or unicast storms with user-defined thresholds
Flow control
provides back pressure using standard IEEE 802.3x, reducing congestion in heavy traffic situations
Security
•
•
•
•
•
•
•
•
Access control list (ACL)
supports powerful ACLs for both IPv4 and IPv6; ACLs are used for filtering traffic to prevent unauthorized users from
accessing the network, or for controlling network traffic to save resources; rules can either deny or permit traffic to be
forwarded; rules can be based on a Layer 2 header or a Layer 3 protocol header; rules can be set to operate on specific
dates or times
Remote Authentication Dial-In User Service (RADIUS)
eases switch security access administration by using a password authentication server
Terminal Access Controller Access-Control System (TACACS+)
delivers an authentication tool using TCP with encryption of the full authentication request, providing additional security
Secure shell (SSHv2)
uses external servers to securely log in to a remote device; with authentication and encryption, it protects against IP
spoofing and plain-text password interception; increases the security of Secure FTP (SFTP) transfers
DHCP snooping
helps ensure that DHCP clients receive IP addresses from authorized DHCP servers and maintain a list of DHCP entries
for trusted ports; prevents reception of fake IP addresses and reduces ARP attacks, improving security
IP Source Guard
filters packets on a per-port basis, which prevents illegal packets from being forwarded
ARP attack protection
protects against attacks that use a large number of ARP requests, using a host-specific, user-selectable threshold
Port security
allows access only to specified MAC addresses, which can be learned or specified by the administrator
Multicast support
•
•
Internet Group Management Protocol (IGMP)
utilizes Any-Source Multicast (ASM) or Source-Specific Multicast (SSM) to manage IPv4 multicast networks; supports
IGMPv1, v2, and v3
Protocol Independent Multicast (PIM)
defines modes of Internet IPv4 and IPv6 multicasting to allow one-to-many and many-to-many transmission of
information; PIM Dense Mode (DM), Sparse Mode (SM), and Source-Specific Mode (SSM) are supported
Warranty and support
•
•
1-year warranty
See http://www.hpe.com/networking/warrantysummary for warranty and support information included with your
product purchase.
Software releases
to find software for your product, refer to http://www.hpe.com/networking/support; for details on the software
Page 7
QuickSpecs
HPE FlexFabric 12900 Switch Series
Overview
releases available with your product purchase, refer to http://www.hpe.com/networking/warrantysummary
Page 8
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Build To Order: BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or RackShippable solution.
HPE FlexFabric 12904E Switch Chassis
• 2 - MPUx (Management Ports)
• 4 - I/O module slots
• 6 - Fabric module slots
• Must select min 1 Management Module
• Must select min 2 Power Supplies
• Must select Min 1 Fabric Module
• Must select Min 2 Fan Trays
• 6U Height Rack
JH262A
HPE FlexFabric 12908E Switch Chassis
• 2 - MPUx (Management Ports)
• 8 - I/O module slots
• 6 - Fabric module slots
• Must select min 1 Management Module
• Must select min 2 Power Supplies
• Must select Min 1 Fabric Module
• Must select Min 2 Fan Trays
• 12U Height Rack
JH255A
HPE FlexFabric 12910 Switch AC Chassis
• 2 - MPUx (Management Ports)
• 10 - I/O module slots
• 6 - Fabric module slots
• Must select min 1 Management Module
• Must select min 2 Power Supply
• Must select Min 1 Fabric Module
• 21U Height Rack
JG619A
See Configuration
NOTE: 1, 2
PDU Cable NA/MEX/TW/JP
• C19 PDU Jumper Cord (NA/MEX/TW/JP)
JG619A#B2B
PDU Cable ROW
• C19 PDU Jumper Cord (ROW)
JG619A#B2C
High Volt Switch to Wall Power Cord
JG619A#B2E
Page 9
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
•
NEMA L6-20P Cord (NA/MEX/JP/TW)
No Power Cord
• No Localized Power Cord Selected
HPE FlexFabric 12916 Switch AC Chassis
• 2 - MPUx (Management Ports)
• 16 - I/O module slots
• 6 - Fabric module slots
• Must select min 1 Management Module
• Must select min 2 Power Supplies
• Must select Min 1 Fabric Module
• 23U Height Rack
JG619A#AC3
JG632A
See Configuration
NOTE: 1, 2
PDU Cable NA/MEX/TW/JP
• C19 PDU Jumper Cord (NA/MEX/TW/JP)
JG632A#B2B
PDU Cable ROW
• C19 PDU Jumper Cord (ROW)
JG632A#B2C
High Volt Switch to Wall Power Cord
• NEMA L6-20P Cord (NA/MEX/JP/TW)
JG632A#B2E
HPE FlexFabric 12916E Switch Chassis
• 2 - MPUx (Management Ports)
• 16 - I/O module slots
• 6 - Fabric module slots
• Must select min 1 Management Module
• Must select min 2 Power Supplies
• Must select Min 1 Fabric Module
• Must select Min 2 Fan Trays
• 21U Height Rack
JH103A
Configuration Rules
Note 1
Note 2
If this Switch is selected at least 2 of these Power Supplies are required:
HPE 12500 2000W AC Power Supply
JF429A
Localization required on orders without #B2B, #B2C or #B2E options.
Modules
Page 10
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Fabric Modules
JG619A, JH113A, JG632A System (std 0 // max 6) User Selection (min 4 // max 6) per Switch
JH262A, JH255A, JH103A System (std 0 // max 6) User Selection (min 1 // max 6) per switch enclosure
HPE FlexFabric 12904E 2.5Tbps Type F Fabric Module
JH264A
See Configuration
NOTE: 1, 4
HPE FlexFabric 12908E 5.0Tbps Type F Fabric Module
JH257A
See Configuration
NOTE: 1, 5
HPE FlexFabric 12910 1.92Tbps Type A Fabric Module
JG622A
See Configuration
NOTE: 1, 2
HPE FlexFabric 12910 3.84Tbps Type B Fabric Module
JG623A
See Configuration
NOTE: 1, 2
HPE FlexFabric 12916E 10.0Tbps Type F Fabric Module
JH252A
See Configuration
NOTE: 1, 6
HPE FlexFabric 12916 6.14Tbps Type B Fabric Module
JG636A
See Configuration
NOTE: 1, 3
HPE FlexFabric 12916 2.56Tbps Type S Fabric Module
JG854A
See Configuration
NOTE: 1, 3
Configuration Rules:
Note 1
If more than 1 Fabric Module is selected, they must be of the same Type.
Note 2
This Fabric Module is only supported on switch JG619A.
Note 3
This Fabric Module is only supported on switch JG632A.
Note 4
This Fabric Module is only supported on switch JH262A.
Note 5
This Fabric Module is only supported on switch JH255A.
Page 11
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Note 6
This Fabric Module is only supported on switch JH103A.
Management Modules
System (std 0 // max 2) User Selection (min 1 // max 2) per Switch
HPE FlexFabric 12910 Main Processing Unit
•
No supported Transceivers
HPE FlexFabric 12916 Main Processing Unit
•
No supported Transceivers
HPE FlexFabric 12900E Main Processing Unit
•
No supported Transceivers
HPE FlexFabric 12904E Main Processing Unit
•
No supported Transceivers
JG621A
See Configuration
NOTE: 1
JG634A
See Configuration
NOTE: 2
JH104A
See Configuration
NOTE: 3
JH263A
See Configuration
NOTE: 4
Configuration Rules:
Note 1
Note 2
Note 3
Note 4
The following Switches support this Module:
HPE FlexFabric 12910 Switch AC Chassis
JG619A
The following Switches support this Module:
HPE FlexFabric 12916 Switch AC Chassis
JG632A
The following Switches support this Module:
HPE FlexFabric 12908E Switch Chassis
HPE FlexFabric 12916E Switch Chassis
JH255A
JH103A
The following Switches support this Module:
HPE FlexFabric 12904E Switch Chassis
JH262A
Accessory
HPE FlexFabric 12900E LPU Adapter
JH107A
See Configuration
NOTE: 1
Configuration Rules
Page 12
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Note 1
This Module is REQUIRED if any I/O module is added to the below switches: (1 per module)
HPE FlexFabric 12904E Switch Chassis
HPE FlexFabric 12908E Switch Chassis
HPE FlexFabric 12916E Switch Chassis
JH262A
JH255A
JH103A
I/O Modules
JG619A, JH113A - System (std 0 // max 10) User Selection (min 1 // max 10)
JG632A - System (std 0 // max 16) User Selection (min 1 // max 16)
12904E (std 0 // max 4) User Selection (min 1 // max 4) per switch enclosure
12908E (std 0 // max 8) User Selection (min 1 // max 8) per switch enclosure
12916E (std 0 // max 16) User Selection (min 1 // max 16) per switch enclosure
HPE FlexFabric 12900 48-port GbE SFP EB Module
• Min 0 // Max 48 SFP+ Transceivers
JG855A
See Configuration
NOTE: 1, 6
HPE FlexFabric 12900 48-port 10/100/1000BASE-T EB Module
• No supported Transceiver
JG856A
See Configuration
NOTE: 6
HPE FlexFabric 12900 48-port 10/100/1000BASE-T FX Module
JH242A
See Configuration
NOTE: 6
•
No supported Transceivers
HPE FlexFabric 12900 48-port 1/10GBASE-T FX Module
•
No supported Transceivers
HPE FlexFabric 12900 48-port GbE SFP FX Module
•
Min 0 // Max 48 SFP Transceivers
JH007A
See Configuration
NOTE: 6, 11
JH241A
See Configuration
NOTE: 1, 6
HPE FlexFabric 12900 48-port 10GbE SFP+ EA Module
• Min 0 // Max 48 SFP+ Transceivers
JG624A
See Configuration
NOTE: 1, 2, 4, 6
HPE FlexFabric 12900 48-port 1/10GbE SFP+ EC Module
• Min 0 // Max 48 SFP+ Transceivers
JG626A
See Configuration
NOTE: 1, 2, 4, 6
HPE FlexFabric 12900 48-port 1/10GbE SFP+ FE Module
• Min 0 // Max 48 SFP+ Transceivers
JH249A
See Configuration
NOTE: 1, 2, 6, 11, 13
Page 13
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
HPE FlexFabric 12900 36-port 40GbE QSFP+ FX Module
• Min 0 // Max 36 QSFP+ Transceivers
JH045A
See Configuration
NOTE: 3, 6, 11
HPE FlexFabric 12900 24-port 40GbE QSFP+ FE Module
JH250A
See Configuration
NOTE: 3, 6, 11
•
Min 0 // Max 24 QSFP+ Transceivers
HPE FlexFabric 12900 48-port 1/10GbE SFP+ FX Module
• Min 0 // Max 48 SFP+ Transceivers
JG888B
See Configuration
NOTE: 1, 2, 6, 11, 13
HPE FlexFabric 12900 24-port 40GbE QSFP+ FX Module
JG889B
See Configuration
NOTE: 3, 6, 11
•
Min 0 // Max 24 QSFP+ Transceivers
HPE FlexFabric 12900 16-port 40GbE QSFP+ EA Module
• Min 0 // Max 16 QSFP+ Transceivers
JG625A
See Configuration
NOTE: 3, 6
HPE FlexFabric 12900 12-port 40GbE QSFP+ EC Module
• Min 0 // Max 12 QSFP+ Transceivers
JG857A
See Configuration
NOTE: 3, 6
HPE FlexFabric 12900 12-port 40GbE QSFP+ FX Module
JH005A
See Configuration
NOTE: 3, 6, 11
•
Min 0 // Max 12 QSFP+ Transceivers
HPE FlexFabric 12900 4-port 100GbE CFP EC Module
• Min 0 // Max 4 CFP Transceivers
JG858A
See Configuration
NOTE: 5, 6
HPE FlexFabric 12900 8-port 100GbE CXP FX Module
JH006A
See Configuration
NOTE: 6, 7, 11
•
Min 0 // Max 8 CXP Transceivers
HPE FlexFabric 12900 8-port 100GbE CFP2 FX Module
•
Min 0 // Max 8 CFP2 Transceivers
JH288A
See Configuration
NOTE: 6, 11, 12
Configuration Rules
Note 1
The following Transceivers install into this Module:
HPE X170 1G SFP LC LH70 1550 Transceiver
HPE X170 1G SFP LC LH70 1570 Transceiver
JD109A
JD110A
Page 14
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Note 2
Note 3
Note 4
Note 5
HPE X170 1G SFP LC LH70 1590 Transceiver
HPE X170 1G SFP LC LH70 1610 Transceiver
HPE X170 1G SFP LC LH70 1510 Transceiver
HPE X120 1G SFP LC LH100 Transceiver
HPE X125 1G SFP LC LH40 1310nm Transceiver
HPE X120 1G SFP LC LH40 1550nm Transceiver
HPE X120 1G SFP RJ45 T Transceiver
HPE X120 1G SFP LC SX Transceiver
HPE X120 1G SFP LC LX Transceiver
HPE X125 1G SFP LC LH70 Transceiver
HPE X120 1G SFP LC BX 10-U Transceiver
HPE X120 1G SFP LC BX 10-D Transceiver
JD111A
JD112A
JD115A
JD103A
JD061A
JD062A
JD089B
JD118B
JD119B
JD063B
JD098B
JD099B
The following Transceivers install into this Module:
HPE X130 10G SFP+ LC SR Transceiver
HPE X130 10G SFP+ LC LR Transceiver
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable
HPE X130 10G SFP+ LC ER 40km Transceiver
HPE X130 10G SFP+ LC LH 80km Transceiver
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable
JD092B
JD094B
JD095C
JD096C
JD097C
JG081C
JC784C
JG234A
JG915A
JL290A
JL291A
JL292A
The following 40G Transceivers install into this Module:
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
HPE X140 40G QSFP+ MPO SR4 Transceiver
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable
HPE X140 40G QSFP+ LC LR4L 2km SM XCVR
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JG661A
JL251A
JG325B
JG709A
JG326A
JG327A
JG328A
JG329A
JG330A
JG331A
JL286A
JL287A
JL288A
JL289A
The following Transceivers install into this Module:
HPE X130 10G SFP+ LC LRM Transceiver
JD093B
The following Transceivers install into this Module:
HP X150 100G CFP LC LR4 10km SM Transceiver
JG829A
Page 15
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Note 6
FC/FX Modules If (JG619A, JG632A, or JH113A) AND (JH006A, JG888B, JG889B, JH005A,
JH007A, JH121A, JH117A, JH249A, JH045A, JH250A, JH118A, JH119A, JH120A, or JH288A) are
selected, Then cannot be used in conjunction with EA, EB or EC Modules JG855A, JG856A,
JH242A, JG624A, JH241A, JG626A, JG625A, JG857A, or JG858A.
Note 7
The following CXP Transceivers install into this Module:
HPE X150 100G CXP MPO SR 100m Multimode Transceiver
HPE X2A0 100G CXP CXP 10m Active Optical Cable
HPE X2A0 100G CXP CXP 30m Active Optical Cable
JG881A
JG882A
JG883A
The following switches only support these modules: ( FX, FE line cards modules )
HPE FlexFabric 12904E Switch Chassis
HPE FlexFabric 12908E Switch Chassis
HPE FlexFabric 12916E Switch Chassis
JH262A
JH255A
JH103A
The following Transceivers install into this Module:
HPE X150 100G CFP2 LC LR4 10km SM Transceiver
JH289A
The following LC Transceiver install into this module:
HPE X130 10G SFP+ LC LH80 tunable Transceiver
JL250A
Note 11
Note 12
Note 13
Remarks: CONFIGURATOR BLUE TEXT: The 12900 switch software image for FX/FC LPUs does not
support EA, EB & EC LPUs and vice versa.
Transceivers
SFP Transceivers
HPE X120 1G SFP RJ45 T Transceiver
HPE X120 1G SFP LC BX 10-U Transceiver
HPE X120 1G SFP LC BX 10-D Transceiver
HPE X120 1G SFP LC LH100 Transceiver
HPE X120 1G SFP LC LH40 1550nm Transceiver
HPE X120 1G SFP LC SX Transceiver
HPE X120 1G SFP LC LX Transceiver
HPE X125 1G SFP LC LH40 1310nm Transceiver
HPE X125 1G SFP LC LH70 Transceiver
HPE X170 1G SFP LC LH70 1550 Transceiver
HPE X170 1G SFP LC LH70 1570 Transceiver
HPE X170 1G SFP LC LH70 1590 Transceiver
HPE X170 1G SFP LC LH70 1610 Transceiver
HPE X170 1G SFP LC LH70 1510 Transceiver
JD089B
JD098B
JD099B
JD103A
JD062A
JD118B
JD119B
JD061A
JD063B
JD109A
JD110A
JD111A
JD112A
JD115A
Page 16
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
SFP+ Transceivers
HPE X130 10G SFP+ LC SR Transceiver
HPE X130 10G SFP+ LC LRM Transceiver
HPE X130 10G SFP+ LC LR Transceiver
HPE X130 10G SFP+ LC ER 40km Transceiver
HPE X130 10G SFP+ LC LH 80km Transceiver
HPE X130 10G SFP+ LC LH80 tunable Transceiver
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable
JD092B
JD093B
JD094B
JG234A
JG915A
JL250A
JD095C
JD096C
JD097C
JG081C
JC784C
JL290A
JL291A
JL292A
QSFP+ Transceivers
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
HPE X140 40G QSFP+ MPO SR4 Transceiver
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JG661A
JL251A
JG325B
JG709A
JG326A
JG327A
JG328A
JG329A
JG330A
JG331A
JL287A
JL288A
JL289A
CFP2 Transceivers
HPE X150 100G CFP2 LC LR4 10km SM XCVR
JH289A
CXP Transceivers
HPE X150 100G CXP MPO SR 100m Multimode Transceiver
HPE X2A0 100G CXP CXP 10m Active Optical Cable
HPE X2A0 100G CXP CXP 30m Active Optical Cable
JG881A
JG882A
JG883A
Cables
Page 17
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
HPE Multi Fiber Push On to 4 x Lucent Connector 5m Cable
HPE Multi Fiber Push On to 4 x Lucent Connector 15m Cable
K2Q46A
K2Q47A
Internal Power Supplies
12910 (std 0 // max 8) User Selection (min 2 // max 8) per switch enclosure
12916 (std 0 // max 12) User Selection (min 2 // max 12) per switch enclosure
12904E (std 0 // max 4) User Selection (min 2 // max 4) per switch enclosure
12908E (std 0 // max 8) User Selection (min 2 // max 8) per switch enclosure
12916E (std 0 // max 16) User Selection (min 2 // max 16) per switch enclosure
HPE 12500 2000W AC Power Supply
JF429A
See Configuration
NOTE: 3
HPE 12900E 2400W DC PSU
JH269A
See Configuration
NOTE: 4, 5
HPE FlexFabric 12900E 2400W AC Power Supply Unit
JH108A
See Configuration
NOTE: 2, 4
PDU Cable NA/MEX/TW/JP
• C19 PDU Jumper Cord (NA/MEX/TW/JP)
JH108A#B2B
PDU Cable ROW
• C19 PDU Jumper Cord (ROW)
JH108A#B2C
High Volt Switch to Wall Power Cord
• NEMA L6-20P Cord (NA/MEX/JP/TW)
JH108A#B2E
Configuration Rules:
Note 2
Localization (Wall Power Cord) required on orders without #B2B or #B2C (PDU Power Cord).
(See Localization Menu)
Note 3
This Power is only supported on these switches:
HPE FlexFabric 12910 Switch AC Chassis
HPE FlexFabric 12916 Switch AC Chassis
HPE FlexFabric 12910 TAA-compliant Switch AC Chassis
Note 4
JG619A
JG632A
JH113A
This Power is only supported on these switches:
Page 18
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Note 5
HPE FlexFabric 12904E Switch Chassis
HPE FlexFabric 12908E Switch Chassis
HPE FlexFabric 12916E Switch Chassis
JH262A
JH255A
JH103A
One of these cables is required when ordering this power supply:
HPE FlexNetwork 10500 48V 3m DC Power Supply Cable
HPE FlexNetwork 10500 48V 15m DC Power Supply Cable
JG390A
JG391A
Remarks Localization is not required on the internal JF429A HPE 12500 2000W AC Power Supply AC power supplies.
Localization is covered on the chassis.
Drop down under chassis should offer the following options and results:
Switch/Router/Power Supply to PDU Power Cord - #B2B in North America, Mexico, Taiwan, and Japan or #B2C
ROW. (Watson Default B2B or B2C for Rack Level CTO)
Switch/Router/Power Supply to Wall Power Cord - Localized Option (Watson Default for BTO and Box Level CTO)
High Volt Switch/Router/Power Supply to Wall Power Cord - #B2E Option. (Offered only in North America,
Mexico, Taiwan, and Japan)
Switch Enclosure Options
Mounting Kit
HPE X421 Chassis Universal 4-post Rackmount Kit
JC665A
See Configuration
NOTE: 1
Configuration Rules
Note 1
This item is optional and used by customers to allow the chassis to slide in and out of the rack
Remarks: Default a quantity of 1 when Switch is selected.
Air Filters
HPE FlexFabric 12910 Optional Air Filter
JG876A
Remarks: Supported on JG619A
HPE FlexFabric 12916 Optional Air Filter
JG877A
Remarks: Supported on JG632A
Fans
12904E, 12908E, and 12916E (std 0 // max 2) User Selection (min 2 // max 2) per switch enclosure
HPE FlexFabric 12910 Spare Fan Assembly
JG631A
Page 19
QuickSpecs
HPE FlexFabric 12900 Switch Series
Configuration
Remarks: Spare only; Included in Chassis - Supported on JG619A
HPE FlexFabric 12916 Spare Top Fan Tray Assembly
JG637A
Remarks: Spare only; Included in Chassis - Supported on JG632A
HPE FlexFabric 12916 Spare Bottom Fan Tray Assembly
JG638A
Remarks: Spare only; Included in Chassis - Supported on JG632A
HPE FlexFabric 12916E Fan Tray Assembly
• Supported on JH103A
JH106A
See Configuration
NOTE: 1
HPE FlexFabric 12908E Fan Tray Assembly
• Supported on JH255A
JH258A
See Configuration
NOTE: 2
HPE FlexFabric 12904E Fan Tray Assembly
JH265A
See Configuration
NOTE: 3
•
Supported on JH262A
Configuration Rules
Note 1
If the 12916E switch is selected, then Min 2 / Max 2 Fan Trays are required.
Note 2
If the 12908E switch is selected, then Min 2 / Max 2 Fan Trays are required.
Note 3
If the 12904E switch is selected, then Min 2 / Max 2 Fan Trays are required.
Power Supply Cables
(std 0 // max 1) User Selection (min 1 // max 1) per DC Power Supply
HPE FlexNetwork 10500 48V 3m DC Power Supply Cable
JG390A
HPE FlexNetwork 10500 48V 15m DC Power Supply Cable
JG391A
Page 20
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
HPE FlexFabric 12916 Switch AC Chassis (JG632A)
I/O ports and slots
16 I/O module slots
Supports a maximum of 768 Gigabit Ethernet ports or 768 1/10GbE ports or 768 1/10GBASE-T ports or
384 40GbE ports or 128 100GbE ports, or a combination
Additional ports and
slots
2 MPU (for management modules) slots
6 switch fabric slots
Power supplies
12 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
includes: 1 x JG637A
2 fan tray slots
Physical characteristics Dimensions
Memory and processor
17.32(w) x 32.68(d) x 40.08(h) in (44 x 83 x 101.8 cm) (23U height)
Weight
163.69 lb (74.25 kg)
Full configuration
weight
570.15 lb (258.62 kg)
Management module
Quad Core MIPS64 @ 1.2 GHz, 1 GB flash, 8 GB DDR2 SDRAM
Mounting and enclosure Mounts in an EIA standard 19-inch rack or other equipment cabinet (hardware included); Horizontal
surface mounting only
Performance
Throughput
up to 57.6 Bpps (64-byte packets)
Switching capacity
46 Tbps
Reliability
Availability
99.999%
Environment
Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative
humidity
10% to 95%, noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
5% to 95%, noncondensing
Altitude
up to 13,123 ft (4 km)
Acoustic
Low-speed fan: 60.2 dB, High-speed fan: 86.3 dB
Airflow direction
Side-to-side
Electrical characteristics Frequency
50/60 Hz
Voltage
100 - 120 / 200 - 240 VAC, rated
Current
16/60 A
Power output
2000 W
Notes
Based on a common power supply of 2,000 W (AC)
Safety
UL 60950-1; CAN/CSA 22.2 No. 60950-1; IEC 60950-1; EN 60950-1; FDA 21 CFR Subchapter J; AS/NZS
60950-1; RoHS Compliance EN 50581
Emissions
VCCI Class A
EN 55022 Class A
CISPR 22 Class A
IEC/EN 61000-3-2
Page 21
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
IEC/EN 61000-3-3
ICES-003 Class A
AS/NZS CISPR 22 Class A
FCC (CFR 47, Part 15) Class A
ETSI EN 300 386
Immunity
Generic
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS232C); SNMP Manager; Telnet; terminal interface (serial RS-232C); modem interface; IEEE 802.3
Ethernet MIB; Ethernet Interface MIB
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.
EN 55024
HPE FlexFabric 12910 Switch AC Chassis (JG619A)
I/O ports and slots
10 I/O module slots
Supports a maximum of 480 10GbE ports or 480 1/10GBASE-T ports or 480 1/10GbE ports or 480
Gigabit Ethernet ports or 480 autosensing 10/100/1000 ports or 360 40GbE ports or 80 100GbE ports,
or a combination
Additional ports and
slots
2 MPU (for management modules) slots
6 switch fabric
Power supplies
8 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
includes: 2 x JG631A
2 fan tray slots
Physical characteristics Dimensions
Memory and processor
17.32(w) x 32.68(d) x 36.61(h) in (43.99 x 83 x 92.99 cm) (21U height)
Weight
187.46 lb (85.03 kg)
Full configuration
weight
474.45 lb (215.21 kg)
Management module
Quad Core MIPS64 @ 1.2 GHz, 1 GB flash, 8 GB DDR2 SDRAM
Mounting and enclosure Mounts in an EIA standard 19-inch rack or other equipment cabinet (hardware included); Horizontal
surface mounting only
Performance
Throughput
up to 36 Bpps (64-byte packets)
Switching capacity
28.8 Tbps
Reliability
Availability
99.999%
Environment
Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative
humidity
10% to 95%, noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
5% to 95%, noncondensing
Altitude
up to 13,123 ft (4 km)
Acoustic
Low-speed fan: 60.2 dB, High-speed fan: 83.9 dB
Airflow direction
Front-to-back
Page 22
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
Electrical characteristics Frequency
50/60 Hz
Voltage
100 - 120 / 200 - 240 VAC, rated
Current
16/60 A
Power output
2000 W
Notes
Based on a common power supply of 2,000 W (AC)
Safety
UL 60950-1; CAN/CSA 22.2 No. 60950-1; IEC 60950-1; EN 60950-1; FDA 21 CFR Subchapter J; AS/NZS
60950-1; RoHS Compliance EN 50581
Emissions
VCCI Class A
EN 55022 Class A
CISPR 22 Class A
IEC/EN 61000-3-2
IEC/EN 61000-3-3
ICES-003 Class A
AS/NZS CISPR 22 Class A
FCC (CFR 47, Part 15) Class A
ETSI EN 300 386
Immunity
Generic
Management
IMC - Intelligent Management Center; command-line interface; out-of-band management (serial RS232C); SNMP Manager; Telnet; terminal interface (serial RS-232C); modem interface; IEEE 802.3
Ethernet MIB; Ethernet Interface MIB
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.
EN 55024
HPE FlexFabric 12916E Switch Chassis (JH103A)
I/O ports and slots
16 I/O module slots
Supports a maximum of 768 10GbE ports or 768 1/10GBASE-T ports or 768 1/10GbE ports or 768
Gigabit Ethernet ports or 768 autosensing 10/100/1000 ports or 576 40GbE ports or 128 100GbE ports,
or a combination
Additional ports and
slots
2 MPU (for management modules) slots
6 switch fabric slots
Power supplies
16 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
Fan trays are not included.
Physical characteristics Dimensions
Memory and processor
17.32(w) x 33.74(d) x 36.65(h) in (43.99 x 85.7 x 93.1 cm) (21U height)
Weight
189.82 lb (86.1 kg)
Management module
Quad Core MIPS64 @ 1.2 GHz, 1 GB flash, 8 GB DDR2 SDRAM
Mounting and enclosure Mounts in an EIA standard 19-inch rack or other equipment cabinet (hardware included); Horizontal
surface mounting only
Performance
Throughput
up to 57.6 Bpps (64-byte packets)
Switching capacity
46 Tbps
Reliability
Availability
99.999%
Environment
Operating temperature 32°F to 104°F (0°C to 40°C)
Page 23
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
Operating relative
humidity
5% to 95%, noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
5% to 95%, noncondensing
Altitude
up to 13,123 ft (4 km)
Acoustic
Low-speed fan: 67.8 dB, High-speed fan: 91.2 dB; ISO 7779
Airflow direction
Front-to-back
Electrical characteristics Frequency
50/60 Hz
Voltage
100 - 240 VAC, rated
-48 to -60 VDC, rated
(depending on power supply chosen)
Current
16 A
Power output
2400 W
Frequency
50/60 Hz
Notes
Based on a common power supply of 2,400 W (AC)
Safety
UL 60950-1
CAN/CSA 22.2 No. 60950-1
IEC 60950-1
EN 60950-1
FDA 21 CFR Subchapter J
AS/NZS 60950-1
RoHS Compliance EN 50581
Emissions
VCCI Class A; EN 55022 Class A; CISPR 22 Class A; IEC/EN 61000-3-2; IEC/EN 61000-3-3; ICES-003
Class A; AS/NZS CISPR 22 Class A; FCC (CFR 47, Part 15) Class A; ETSI EN 300 386
Immunity
Generic
Management
IMC - Intelligent Management Center; Command-line interface; Out-of-band management (serial RS232c); SNMP manager; Telnet; Terminal interface (serial RS-232c); Modem interface; IEEE 802.3
Ethernet mib; Ethernet interface mib
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.
EN 55024
HPE FlexFabric 12908E Switch Chassis (JH255A)
I/O ports and slots
8 I/O module slots
Supports a maximum of 384 10GbE ports or 384 1/10GBASE-T ports or 384 1/10GbE ports or 384
Gigabit Ethernet ports or 384 autosensing 10/100/1000 ports or 288 40GbE ports or 64 100GbE
ports, or a combination
Additional ports and
slots
2 MPU (for management modules) slots
6 switch fabric slots
Power supplies
8 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
Page 24
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
Fan trays are not included.
Physical characteristics
Memory and processor
Dimensions
17.32(w) x 33.74(d) x 20.91(h) in (43.99 x 85.7 x 53.1 cm) (12U height)
Weight
103.62 lb (47 kg)
Management module
Quad Core MIPS64 @ 1.2 GHz, 1 GB flash, 8 GB DDR3 SDRAM
Mounting and enclosure Mounts in an EIA standard 19-inch rack or other equipment cabinet (hardware included); Horizontal
surface mounting only
Performance
Throughput
up to 68.5 Bpps (64-byte packets)
Switching capacity
57.6 Tbps
Reliability
Availability
99.999%
Environment
Operating temperature 32°F to 104°F (0°C to 40°C)
Operating relative
humidity
5% to 95%, noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
5% to 95%, noncondensing
Altitude
up to 13,123 ft (4 km)
Acoustic
Low-speed fan: 62.1 dB, High-speed fan: 87.6 dB; ISO 7779
Airflow direction
Front-to-back
Electrical characteristics Frequency
50/60 Hz
Voltage
100 - 240 VAC, rated
-48 to -60 VDC, rated
(depending on power supply chosen)
Current
16 A
Power output
2400 W
Notes
Based on a common power supply of 2,400 W (AC)
Safety
UL 60950-1; CAN/CSA 22.2 No. 60950-1; IEC 60950-1; EN 60950-1; FDA 21 CFR Subchapter J; AS/NZS
60950-1; RoHS Compliance EN 50581
Emissions
VCCI Class A; EN 55022 Class A; CISPR 22 Class A; IEC/EN 61000-3-2; IEC/EN 61000-3-3; ICES-003
Class A; AS/NZS CISPR 22 Class A; FCC (CFR 47, Part 15) Class A; ETSI EN 300 386
Immunity
Generic
Management
IMC - Intelligent Management Center; Command-line interface; Out-of-band management (serial RS232c); SNMP manager; Telnet; Terminal interface (serial RS-232c); Modem interface; IEEE 802.3
Ethernet mib; Ethernet interface mib
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.
EN 55024
HPE FlexFabric 12904E Switch Chassis (JH262A)
I/O ports and slots
4 I/O module slots
Supports a maximum of 192 10GbE ports or 192 1/10GBASE-T ports or 192 1/10GbE ports or 192 Gigabit
Ethernet ports or 192 autosensing 10/100/1000 ports or 144 40GbE ports or 32 100GbE ports, or a
combination
Page 25
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
Additional ports and
slots
2 MPU (for management modules) slots
6 switch fabric slots
Power supplies
4 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
Fan trays are not included.
Physical characteristics Dimensions
Memory and processor
17.32(w) x 33.74(d) x 10.39(h) in (43.99 x 85.7 x 26.39 cm) (6U height)
Weight
79.37 lb (36 kg)
Management module
Quad Core MIPS64 @ 1.2 GHz, 1 GB flash, 8 GB DDR3 SDRAM
Mounting and enclosure Mounts in an EIA standard 19-inch rack or other equipment cabinet (hardware included); Horizontal
surface mounting only
Performance
Throughput
up to 34.2 Bpps (64-byte packets)
Switching capacity
28.8 Tbps
Reliability
Availability
99.999%
Environment
Operating temperature 32°F to 104°F (0°C to 40°C)
Operating relative
humidity
5% to 95%, noncondensing
Nonoperating/Storage
temperature
-40°F to 158°F (-40°C to 70°C)
Nonoperating/Storage
relative humidity
5% to 95%, noncondensing
Altitude
up to 13,123 ft (4 km)
Acoustic
Low-speed fan: 67.5 dB, High-speed fan: 85.3 dB; ISO 7779
Airflow direction
Front-to-back
Electrical characteristics Frequency
50/60 Hz
Voltage
100 - 240 VAC, rated
-48 to -60 VDC, rated
(depending on power supply chosen)
Current
16 A
Power output
2400 W
Notes
Based on a common power supply of 2,400 W (AC)
Safety
UL 60950-1; CAN/CSA 22.2 No. 60950-1; IEC 60950-1; EN 60950-1; FDA 21 CFR Subchapter J; AS/NZS
60950-1; RoHS Compliance EN 50581
Emissions
VCCI Class A; EN 55022 Class A; CISPR 22 Class A; IEC/EN 61000-3-2; IEC/EN 61000-3-3; ICES-003
Class A; AS/NZS CISPR 22 Class A; FCC (CFR 47, Part 15) Class A; ETSI EN 300 386
Immunity
Generic
Management
IMC - Intelligent Management Center; Command-line interface; Out-of-band management (serial RS232c); SNMP manager; Telnet; Terminal interface (serial RS-232c); Modem interface; IEEE 802.3
Ethernet mib; Ethernet interface mib
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.
EN 55024
Page 26
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
Standards and protocols BGP
(applies to all products in RFC 1771 BGPv4
series)
RFC 1772 Application of the BGP
RFC 1997 BGP Communities Attribute
RFC 1998 An Application of the BGP Community
Attribute in Multi-home Routing
RFC 2385 BGP Session Protection via TCP MD5
RFC 2439 BGP Route Flap Damping
RFC 2796 BGP Route Reflection
RFC 2858 BGP-4 Multi-Protocol Extensions
RFC 2918 Route Refresh Capability
RFC 3065 Autonomous System Confederations for
BGP
RFC 3392 Capabilities Advertisement with BGP-4
RFC 4271 A Border Gateway Protocol 4 (BGP-4)
RFC 4272 BGP Security Vulnerabilities Analysis
RFC 4273 Definitions of Managed Objects for BGP4
RFC 4274 BGP-4 Protocol Analysis
RFC 4275 BGP-4 MIB Implementation Survey
RFC 4276 BGP-4 Implementation Report
RFC 4277 Experience with the BGP-4 Protocol
RFC 4360 BGP Extended Communities Attribute
RFC 4456 BGP Route Reflection: An Alternative to
Full Mesh Internal BGP (IBGP)
RFC 5291 Outbound Route Filtering Capability for
BGP-4
RFC 5292 Address-Prefix-Based Outbound Route
Filter for BGP-4
RFC 3307 IPv6 Multicast Address Allocation
RFC 3315 DHCPv6 (client and relay)
RFC 3484 Default Address Selection for IPv6
RFC 3513 IPv6 Addressing Architecture
RFC 3736 Stateless Dynamic Host Configuration
Protocol (DHCP) Service for IPv6
RFC 3810 MLDv2 for IPv6
RFC 4214 Intra-Site Automatic Tunnel Addressing
Protocol (ISATAP)
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Autoconfiguration
MIBs
RFC 1156 (TCP/IP MIB)
RFC 1157 A Simple Network Management Protocol
(SNMP)
RFC 1215 A Convention for Defining Traps for use
with the SNMP
RFC 1229 Interface MIB Extensions
RFC 1493 Bridge MIB
RFC 1573 SNMP MIB II
RFC 1643 Ethernet MIB
RFC 1657 BGP-4 MIB
RFC 1724 RIPv2 MIB
RFC 1907 SNMPv2 MIB
RFC 2011 SNMPv2 MIB for IP
RFC 2012 SNMPv2 MIB for TCP
RFC 2013 SNMPv2 MIB for UDP
RFC 2096 IP Forwarding Table MIB
Denial of service protection
RFC 2233 Interface MIB
Automatic filtering of well-known denial-of-service RFC 2452 IPV6-TCP-MIB
packets
RFC 2454 IPV6-UDP-MIB
CPU DoS Protection
RFC 2465 IPv6 MIB
Rate Limiting by ACLs
RFC 2466 ICMPv6 MIB
RFC 2571 SNMP Framework MIB
Device management
RFC 2572 SNMP-MPD MIB
RFC 1157 SNMPv1/v2c
RFC 2573 SNMP-Notification MIB
RFC 1305 NTPv3
RFC 2573 SNMP-Target MIB
RFC 1902 (SNMPv2)
RFC 2578 Structure of Management Information
RFC 2579 (SMIv2 Text Conventions)
Version 2 (SMIv2)
RFC 2580 (SMIv2 Conformance)
RFC 2580 Conformance Statements for SMIv2
RFC 2819 (RMON groups Alarm, Event, History and RFC 2618 RADIUS Client MIB
Statistics only)
RFC 2620 RADIUS Accounting MIB
HTTP, SSHv1, and Telnet
RFC 2665 Ethernet-Like-MIB
Multiple Configuration Files
RFC 2668 802.3 MAU MIB
Multiple Software Images
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
SSHv1/SSHv2 Secure Shell
RFC 2787 VRRP MIB
Page 27
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
TACACS/TACACS+
Web UI
General protocols
IEEE 802.1ad Q-in-Q
IEEE 802.1ag Service Layer OAM
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1w Rapid Reconfiguration of Spanning
Tree
IEEE 802.3ab 1000BASE-T
IEEE 802.3ac (VLAN Tagging Extension)
IEEE 802.3ad Link Aggregation Control Protocol
(LACP)
IEEE 802.3ae 10-Gigabit Ethernet
IEEE 802.3ah Ethernet in First Mile over Point to
Point Fiber – EFMF
IEEE 802.3ba 40 and 100 Gigabit Ethernet
Architecture
IEEE 802.3x Flow Control
IEEE 802.3z 1000BASE-X
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 791 IP
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 894 IP over Ethernet
RFC 925 Multi-LAN Address Resolution
RFC 950 Internet Standard Subnetting Procedure
RFC 959 File Transfer Protocol (FTP)
RFC 1027 Proxy ARP
RFC 1035 Domain Implementation and
Specification
RFC 1042 IP Datagrams
RFC 1058 RIPv1
RFC 1142 OSI IS-IS Intra-domain Routing Protocol
RFC 1195 OSI ISIS for IP and Dual Environments
RFC 1213 Management Information Base for
Network Management of TCP/IP-based internets
RFC 1293 Inverse Address Resolution Protocol
RFC 1305 NTPv3
RFC 1350 TFTP Protocol (revision 2)
RFC 1393 Traceroute Using an IP Option
RFC 1519 CIDR
RFC 1531 Dynamic Host Configuration Protocol
RFC 2819 RMON MIB
RFC 2925 Ping MIB
RFC 2932IP (Multicast Routing MIB)
RFC 2933 IGMP MIB
RFC 2934 Protocol Independent Multicast MIB for
IPv4
RFC 3414 SNMP-User based-SM MIB
RFC 3415 SNMP-View based-ACM MIB
RFC 3417 Simple Network Management Protocol
(SNMP) over IEEE 802 Networks
RFC 3418 MIB for SNMPv3
RFC 3595 Textual Conventions for IPv6 Flow Label
RFC 3621 Power Ethernet MIB
RFC 3813 MPLS LSR MIB
RFC 3814 MPLS FTN MIB
RFC 3815 MPLS LDP MIB
RFC 3826 AES for SNMP's USM MIB
RFC 4133 Entity MIB (Version 3)
RFC 4444 Management Information Base for
Intermediate System to Intermediate System (ISIS)
MPLS
RFC 2205 Resource ReSerVation Protocol
RFC 2209 Resource ReSerVation Protocol (RSVP)
RFC 2702 Requirements for Traffic Engineering
Over MPLS
RFC 2858 Multiprotocol Extensions for BGP-4
RFC 2961 RSVP Refresh Overhead Reduction
Extensions
RFC 3031 Multiprotocol Label Switching
Architecture
RFC 3032 MPLS Label Stack Encoding
RFC 3107 Carrying Label Information in BGP-4
RFC 3212 Constraint-Based LSP Setup using LDP
RFC 3479 Fault Tolerance for the Label
Distribution Protocol (LDP)
RFC 3487 Graceful Restart Mechanism for LDP
RFC 3564 Requirements for Support of
Differentiated Service-aware MPLS Traffic
Engineering
RFC 4364 BGP/MPLS IP Virtual Private Networks
(VPNs)
RFC 4379 Detecting Multi-Protocol Label Switched
(MPLS) Data Plane Failures
RFC 4447 Pseudowire Setup and Maintenance
Using LDP
RFC 4448 Encapsulation Methods for Transport of
Page 28
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
RFC 1533 DHCP Options and BOOTP Vendor
Extensions
RFC 1591 DNS (client only)
RFC 1624 Incremental Internet Checksum
RFC 1701 Generic Routing Encapsulation
RFC 1721 RIP-2 Analysis
RFC 1723 RIP v2
RFC 1812 IPv4 Routing
RFC 2082 RIP-2 MD5 Authentication
RFC 2091 Trigger RIP
RFC 2131 DHCP
RFC 2138 Remote Authentication Dial In User
Service (RADIUS)
RFC 2236 IGMP Snooping
RFC 2338 VRRP
RFC 2453 RIPv2
RFC 2644 Directed Broadcast Control
RFC 2763 Dynamic Name-to-System ID mapping
support
RFC 2784 Generic Routing Encapsulation (GRE)
RFC 2865 Remote Authentication Dial In User
Service (RADIUS)
RFC 2966 Domain-wide Prefix Distribution with
Two-Level IS-IS
RFC 2973 IS-IS Mesh Groups
RFC 3022 Traditional IP Network Address
Translator (Traditional NAT)
RFC 3277 IS-IS Transient Blackhole Avoidance
RFC 3567 Intermediate System to Intermediate
System (IS-IS) Cryptographic Authentication
RFC 3719 Recommendations for Interoperable
Networks using Intermediate System to
Intermediate System (IS-IS)
RFC 3784 ISIS TE support
RFC 3786 Extending the Number of IS-IS LSP
Fragments Beyond the 256 Limit
RFC 3787 Recommendations for Interoperable IP
Networks using Intermediate System to
Intermediate System (IS-IS)
RFC 3847 Restart signaling for IS-IS
RFC 4251 The Secure Shell (SSH) Protocol
Architecture
RFC 4486 Subcodes for BGP Cease Notification
Message
RFC 4884 Extended ICMP to Support Multi-Part
Messages
RFC 4941 Privacy Extensions for Stateless Address
Autoconfiguration in IPv6
Ethernet over MPLS Networks
RFC 4664 Framework for Layer 2 Virtual Private
Networks
RFC 4665 Service Requirements for Layer 2
Provider Provisioned Virtual Private Networks
RFC 4761 Virtual Private LAN Service (VPLS)
Using BGP for Auto-Discovery and Signaling
RFC 4762 Virtual Private LAN Service (VPLS)
Using Label Distribution Protocol (LDP) Signaling
RFC 5036 LDP Specification
Network management
IEEE 802.1AB Link Layer Discovery Protocol
(LLDP)
RFC 1155 Structure of Management Information
RFC 1157 SNMPv1
RFC 1448 Protocol Operations for version 2 of the
Simple Network Management Protocol (SNMPv2)
RFC 2211 Controlled-Load Network
RFC 2819 Four groups of RMON: 1 (statistics), 2
(history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
RFC 3411 SNMP Management Frameworks
RFC 3412 SNMPv3 Message Processing
RFC 3414 SNMPv3 User-based Security Model
(USM)
RFC 3415 SNMPv3 View-based Access Control
Model VACM)
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
OSPF
RFC 1245 OSPF protocol analysis
RFC 1246 Experience with OSPF
RFC 1765 OSPF Database Overflow
RFC 1850 OSPFv2 Management Information Base
(MIB), traps
RFC 2154 OSPF w/ Digital Signatures (Password,
MD-5)
RFC 2328 OSPFv2
RFC 2370 OSPF Opaque LSA Option
RFC 3101 OSPF NSSA
RFC 3137 OSPF Stub Router Advertisement
RFC 3623 Graceful OSPF Restart
RFC 3630 Traffic Engineering Extensions to
OSPFv2
RFC 4061 Benchmarking Basic OSPF Single Router
Control Plane Convergence
Page 29
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
RFC 5130 A Policy Control Mechanism in IS-IS
Using Administrative Tags
RFC 4062 OSPF Benchmarking Terminology and
Concepts
RFC 4063 Considerations When Using Basic OSPF
Convergence Benchmarks
IP multicast
RFC 4222 Prioritized Treatment of Specific OSPF
RFC 2236 IGMPv2
Version 2 Packets and Congestion Avoidance
RFC 2283 Multiprotocol Extensions for BGP-4
RFC 4577 OSPF as the Provider/Customer Edge
RFC 2362 PIM Sparse Mode
Protocol for BGP/MPLS IP Virtual Private Networks
RFC 3376 IGMPv3
(VPNs)
RFC 3446 Anycast Rendezvous Point (RP)
mechanism using Protocol Independent Multicast RFC 4811 OSPF Out-of-Band LSDB
Resynchronization
(PIM) and Multicast Source Discovery Protocol
RFC 4812 OSPF Restart Signaling
(MSDP)
RFC 4813 OSPF Link-Local Signaling
RFC 3973 PIM Dense Mode
RFC 4940 IANA Considerations for OSPF
RFC 4541 Considerations for Internet Group
Management Protocol (IGMP) and Multicast
Listener Discovery (MLD) Snooping Switches
QoS/CoS
IEEE 802.1p (CoS)
RFC 4601 PIM Sparse Mode
RFC 1349 Type of Service in the Internet Protocol
RFC 4604 Using Internet Group Management
Suite
Protocol Version 3 (IGMPv3) and Multicast
Listener Discovery Protocol Version 2 (MLDv2) for RFC 2211 Specification of the Controlled-Load
Network Element Service
Source-Specific Multicast
RFC 2212 Guaranteed Quality of Service
RFC 4605 IGMP/MLD Proxying
RFC 2474 DSCP DiffServ
RFC 4607 Source-Specific Multicast for IP
RFC 5059 Bootstrap Router (BSR) Mechanism for RFC 2475 DiffServ Architecture
RFC 2597 DiffServ Assured Forwarding (AF)
Protocol Independent Multicast (PIM)
RFC 2598 DiffServ Expedited Forwarding (EF)
IPv6
Security
RFC 1886 DNS Extension for IPv6
RFC 1321 The MD5 Message-Digest Algorithm
RFC 1887 IPv6 Unicast Address Allocation
RFC 1334 PPP Authentication Protocols (PAP)
Architecture
RFC 1492 TACACS+
RFC 1981 IPv6 Path MTU Discovery
RFC 1994 PPP Challenge Handshake
RFC 2080 RIPng for IPv6
RFC 2081 RIPng Protocol Applicability Statement Authentication Protocol (CHAP)RFC 2082 RIP-2
MD5 Authentication
RFC 2292 Advanced Sockets API for IPv6
RFC 2104 Keyed-Hashing for Message
RFC 2373 IPv6 Addressing Architecture
Authentication
RFC 2375 IPv6 Multicast Address Assignments
RFC 2408 Internet Security Association and Key
RFC 2460 IPv6 Specification
Management Protocol (ISAKMP)
RFC 2461 IPv6 Neighbor Discovery
RFC 2409 The Internet Key Exchange (IKE)
RFC 2462 IPv6 Stateless Address AutoRFC 2716 PPP EAP TLS Authentication Protocol
configuration
RFC 2865 RADIUS Authentication
RFC 2463 ICMPv6
RFC 2866 RADIUS Accounting
RFC 2464 Transmission of IPv6 over Ethernet
RFC 2868 RADIUS Attributes for Tunnel Protocol
Networks
Support
RFC 2473 Generic Packet Tunneling in IPv6
RFC 2869 RADIUS Extensions
RFC 2526 Reserved IPv6 Subnet Anycast
Access Control Lists (ACLs)
Addresses
RFC 2529 Transmission of IPv6 Packets over IPv4 Port Security
RFC 2545 Use of MP-BGP-4 for IPv6
Page 30
QuickSpecs
HPE FlexFabric 12900 Switch Series
Technical Specifications
RFC 2553 Basic Socket Interface Extensions for
IPv6
RFC 2710 Multicast Listener Discovery (MLD) for
IPv6
RFC 2740 OSPFv3 for IPv6
RFC 2767 Dual stacks IPv46 & IPv6
RFC 2893 Transition Mechanisms for IPv6 Hosts
and Routers
RFC 3056 Connection of IPv6 Domains via IPv4
Clouds
SSHv1/SSHv2 Secure Shell
VPN
RFC 2403 - HMAC-MD5-96
RFC 2404 - HMAC-SHA1-96
RFC 2405 - DES-CBC Cipher algorithm
RFC 2407 - Domain of interpretation
RFC 2547 BGP/MPLS VPNs
RFC 2917 A Core MPLS IP VPN Architecture
RFC 4302 - IP Authentication Header (AH)
RFC 4303 - IP Encapsulating Security Payload
(ESP)
Page 31
QuickSpecs
HPE FlexFabric 12900 Switch Series
Accessories
HPE FlexFabric 12900 Switch Series accessories
Modules
HPE FlexFabric 12900 48-port 1/10GbE SFP+ FE Module
HPE FlexFabric 12900 24-port 40GbE QSFP+ FE Module
HPE FlexFabric 12900 48-port 1/10GBASE-T FX Module
HPE FlexFabric 12900 48-port 1/10GbE SFP+ FX Module
HPE FlexFabric 12900 36-port 40GbE QSFP+ FX Module
HPE FlexFabric 12900 24-port 40GbE QSFP+ FX Module
HPE FlexFabric 12900 12-port 40GbE QSFP+ FX Module
HPE FlexFabric 12900 8-port 100GbE CFP2 FX Module
HPE FlexFabric 12900 8-port 100GbE CXP FX Module
HPE FlexFabric 12900 48-port 10/100/1000BASE-T FX Module
HPE FlexFabric 12900 48-port GbE SFP FX Module
HPE FlexFabric 12900 48-port 1/10GbE SFP+ EC Module
HPE FlexFabric 12900 12-port 40GbE QSFP+ EC Module
HPE FlexFabric 12900 4-port 100GbE CFP EC Module
HPE FlexFabric 12900 48-port GbE SFP EB Module
HPE FlexFabric 12900 48-port 10/100/1000BASE-T EB Module
HPE FlexFabric 12900 48-port 10GbE SFP+ EA Module
HPE FlexFabric 12900 16-port 40GbE QSFP+ EA Module
JH249A
JH250A
JH007A
JG888B
JH045A
JG889B
JH005A
JH288A
JH006A
JH242A
JH241A
JG626A
JG857A
JG858A
JG855A
JG856A
JG624A
JG625A
Transceivers
HPE X120 1G SFP RJ45 T Transceiver
HPE X120 1G SFP LC SX Transceiver
HPE X120 1G SFP LC LX Transceiver
HPE X125 1G SFP LC LH40 1310nm Transceiver
HPE X120 1G SFP LC LH40 1550nm Transceiver
HPE X125 1G SFP LC LH70 Transceiver
HPE X120 1G SFP LC LH100 Transceiver
HPE X120 1G SFP LC BX 10-D Transceiver
HPE X120 1G SFP LC BX 10-U Transceiver
HPE X170 1G SFP LC LH70 1510 Transceiver
HPE X170 1G SFP LC LH70 1550 Transceiver
HPE X170 1G SFP LC LH70 1590 Transceiver
HPE X170 1G SFP LC LH70 1610 Transceiver
HPE X130 10G SFP+ LC SR Transceiver
HPE X130 10G SFP+ LC LRM Transceiver
HPE X130 10G SFP+ LC LR Transceiver
HPE X130 10G SFP+ LC ER 40km Transceiver
HPE X130 10G SFP+ LC LH 80km Transceiver
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
JD089B
JD118B
JD119B
JD061A
JD062A
JD063B
JD103A
JD099B
JD098B
JD115A
JD109A
JD111A
JD112A
JD092B
JD093B
JD094B
JG234A
JG915A
JD096C
Page 32
QuickSpecs
HPE FlexFabric 12900 Switch Series
Accessories
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver
HPE X140 40G QSFP+ MPO SR4 Transceiver
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable
HPE X150 100G CXP MPO SR 100m Multimode Transceiver
HPE X150 100G CFP2 LC LR4 10km SM Transceiver
HPE X2A0 100G CXP CXP 10m Active Optical Cable
HPE X2A0 100G CXP CXP 30m Active Optical Cable
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver
JD097C
JG081C
JC784C
JG661A
JG709A
JG325B
JL251A
JG326A
JG327A
JG328A
JG329A
JG330A
JD095C
JG331A
JG881A
JH289A
JG882A
JG883A
JL287A
JL288A
JL289A
JL290A
JL291A
JL292A
JL286A
Mounting Kit
HPE X421 Chassis Universal 4-post Rackmount Kit
JC665A
HPE FlexFabric 12916E Switch Chassis (JH103A)
HPE FlexFabric 12900E Main Processing Unit
HPE FlexFabric 12916E 10.0Tbps Type F Fabric Module
HPE FlexFabric 12900E 2400W AC Power Supply Unit
HPE FlexFabric 12900E 2400W DC Power Supply Unit
HPE FlexFabric 12916E Fan Tray Assembly
HPE FlexFabric 12900E LPU Adapter
JH104A
JH252A
JH108A
JH269A
JH106A
JH107A
HPE FlexFabric 12908E Switch Chassis (JH255A)
HPE FlexFabric 12900E Main Processing Unit
HPE FlexFabric 12908E 5.0Tbps Type F Fabric Module
HPE FlexFabric 12900E 2400W AC Power Supply Unit
HPE FlexFabric 12900E 2400W DC Power Supply Unit
HPE FlexFabric 12908E Fan Tray Assembly
HPE FlexFabric 12900E LPU Adapter
JH104A
JH257A
JH108A
JH269A
JH258A
JH107A
Page 33
QuickSpecs
HPE FlexFabric 12900 Switch Series
Accessories
HPE FlexFabric 12904E Switch Chassis (JH262A)
HPE FlexFabric 12904E Main Processing Unit
HPE FlexFabric 12904E 2.5Tbps Type F Fabric Module
HPE FlexFabric 12900E 2400W AC Power Supply Unit
HPE FlexFabric 12900E 2400W DC Power Supply Unit
HPE FlexFabric 12904E Fan Tray Assembly
HPE FlexFabric 12900E LPU Adapter
JH263A
JH264A
JH108A
JH269A
JH265A
JH107A
HPE FlexFabric 12916 Switch AC Chassis (JG632A)
HPE FlexFabric 12916 Main Processing Unit
HPE FlexFabric 12916 6.14Tbps Type B Fabric Module
HPE FlexFabric 12916 2.56Tbps Type S Fabric Module
HPE 12500 2000W AC Power Supply
HPE FlexFabric 12916 Spare Top Fan Tray Assembly
HPE FlexFabric 12916 Spare Bottom Fan Tray Assembly
HPE FlexFabric 12916 Optional Air Filter
JG634A
JG636A
JG854A
JF429A
JG637A
JG638A
JG877A
HPE FlexFabric 12910 Switch AC Chassis (JG619A)
HPE FlexFabric 12910 Main Processing Unit
HPE FlexFabric 12910 3.84Tbps Type B Fabric Module
HPE FlexFabric 12910 1.92Tbps Type A Fabric Module
HPE 12500 2000W AC Power Supply
HPE FlexFabric 12910 Spare Fan Assembly
HPE FlexFabric 12910 Optional Air Filter
JG621A
JG623A
JG622A
JF429A
JG631A
JG876A
Page 34
QuickSpecs
HPE FlexFabric 12900 Switch Series
Summary of Changes
Date
01-Aug-2016
Version History
From Version 20 to
21
Action
Added
Changed
06-June-2016
22-Apr-2016
16-Feb-2016
From Version 19 to
20
From Version 18 to 19
From Version 17 to 18
Added
Changed
Changed
Added
Changed
17-Dec-2015
01-Dec-2015
From Version 16 to 17
From Version 15 to 16
Changed
Added
Changed
12-Oct-2015
02-Oct-2015
28-Sep-2015
From Version 14 to 15
From Version 13 to 14
From Version 12 to 13
Changed
Changed
Added
Changed
01-June-2015
From Version 11 to 12
30-Mar-2015
From Version 10 to 11
Added
Removed
Changed
Added
Changed
26-May-2014
31-Mar-2014
20-Feb-2014
18-Feb-2014
17-Dec-2013
14-Nov-2013
13-Nov-2013
14-Oct-2013
12-Jul-2013
From Version 9 to 10
From Version 8 to 9
From Version 7 to 8
From Version 6 to 7
From Version 5 to 6
From Version 4 to 5
From Version 3 to 4
From Version 2 to 3
From Version 1 to 2
Added
Changed
Removed
Changed
Changed
Removed
Changed
Changed
Changed
Description of Change
SKUs added: JL287A, JL288A, JL289A, JL290A, JL291A,
JL292A, JL250A, JL286A
Adding #AC3 Option on Configuration section. Technical
Specifications updated.
SKUs added: JH269A
Technical Specifications and Configuration sections updated
SKUs descriptions updated on the document
SKU added: JL251A
Features and benefits, Technical Specifications and Standards
and protocols
Technical Specifications updated
SKUs added: JH241A, JH242A, JG882A, JG883A
QuickSpecs name changed from HPE FlexFabric 12900 Switch
Series to HPE FlexFabric 12900 Switch Series
Features and Benefits updated
Configuration section updated
Models added: JH103A, JH255A, JH262A
Changes made on Overview, Technical Specifications and
Accessories
SKUs Added: JG881A, JH006A
SKUs removed: JG915A
Overview and Technical Specifications Updated
Added 5 new accessories: JG888B, JG889B, JH005A, JH007A,
JG915A
Updated Overview, Technical Specification and Accessories
section
Added 2 new accessories: JG888A and JG889A.
Transceivers were revised.
Removed several new accessories
Made significant changes to the Configuration section.
Made a minor change to the Configuration section.
Removed DC voltage
Made significant changes to the Configuration section.
Made minor changes to the Configuration section.
Made minor changes to the Configuration section.
Page 35
QuickSpecs
HPE FlexFabric 12900 Switch Series
Summary of Changes
Sign up for updates
© Copyright 2016 Hewlett Packard Enterprise Development L.P. The information contained herein is
subject to change without notice. The only warranties for Hewlett Packard Enterprise products and
services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise
shall not be liable for technical or editorial errors or omissions contained herein.
To learn more, visit: http://www.hpe/networking
c04111378 - 14676 - Worldwide - V21 - 1-August-2016
Page 36
Download PDF