Champion power equipment 41155 Manual


Add to my manuals
26 Pages

advertisement

Champion power equipment 41155 Manual | Manualzz

Table of Contents

Introduction ..................................... 1

Portable Power Generator........................ 1

Accessories................................................ 1

This Booklet.............................................. 1

Manual Conventions .........................2

Safety Rules ......................................3

Controls and Features.......................5

Generator.................................................. 5

Power Panel ..............................................6

Parts Included .......................................... 7

Assembly ..........................................8

Remove the Generator from the Shipping

Carton .......................................................8

Install the Wheel Kit.................................8

Install the Support Leg.............................8

Connect the Battery ..................................8

Install the Spark Arrester .........................8

Add Engine Oil .........................................8

Add Fuel....................................................9

Grounding.................................................9

Operation ....................................... 10

Generator Location................................. 10

Grounding............................................... 10

Surge Protection ..................................... 10

Starting the Engine................................. 10

Connecting Electrical Loads................... 10

Stopping the Engine ................................11

Do Not Overload Generator ....................11

Capacity................................................11

Power Management .............................11

Wattage Reference Chart.........................11

Maintenance ................................... 13

Engine Maintenance............................... 13

Oil........................................................ 13

Spark Plugs ......................................... 13

Air Filter.............................................. 13

Spark Arrester..................................... 14

Cleaning .............................................. 14

Adjustments........................................ 14

Maintenance Schedule........................ 14

Generator Maintenance.......................... 14

Storage ........................................... 15

Engine Storage ........................................ 15

Generator Storage................................... 15

Specifications ................................. 16

Engine Specifications.............................. 16

Generator Specifications......................... 16

Fuel.......................................................... 16

Oil............................................................ 16

Spark Plugs ............................................. 16

Valve Clearance....................................... 16

Parts Diagram ......................................... 17

Parts List .................................................18

Wiring Schematic................................... 20

Troubleshooting ............................. 21

Warranty ........................................22

Warranty Qualifications .........................22

Repair/Replacement Warranty ..............22

Do not return the unit to the place of purchase ..................................................22

Warranty Exclusions...............................22

Normal Wear.......................................22

Installation, Use and Maintenance.....22

Other Exclusions .................................22

Limits of Implied Warranty and

Consequential Damage ...........................22

Contact Information ...............................23

Address................................................23

Customer Service ................................23

Technical Service.................................23

Notes ..............................................24

Introduction

Introduction

Congratulations on your purchase of a

Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service.

Accessories

Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase. To find out more about our covers, power cables and storm kits, please visit our web site at www.championpowerequipment.com

Portable Power Generator

This Booklet

This unit is a gasoline engine driven, alternating current (AC) generator. It is designed to supply electrical power for lighting, appliances, tools and similar equipment.

Every effort has been made to ensure the

Record the model and serial numbers as well as date and place of purchase for future reference.

Have this information available when ordering parts and when making technical or warranty inquiries. accuracy and completeness of the information in this manual. We reserve the right to change, alter and/or improve the product and this document at any time without prior notice.

Champion Power Equipment Support

1-877-338-0999

Model Number

CSA41155E

Serial Number

Date of Purchase

Purchase Location

Rev CSA41155E-20070416 1

Manual Conventions

Manual Conventions

This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.

Follow all safety messages to avoid or reduce the risk of serious injury or death.

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, or serious injury. will result in death

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, minor or moderate injury. may result in

CAUTION

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

NOTE

If you have questions regarding your generator, we can help. Please call our help line at 1-877-

338-0999.

2

Safety Rules

WARNING

Read this manual thoroughly before operating your generator. Failure to follow instructions could result in serious injury or death.

WARNING

The engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm.

DANGER

Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death.

Operate generator outdoors only in a well ventilated area

DO NOT operate the generator inside any building, enclosure or compartment, including the generator compartment of a recreational vehicle.

DO NOT allow exhaust fumes to enter a confined area through windows, doors, vents or other openings.

DANGER

Rotating parts can entangle hands, feet, hair, clothing and/or accessories.

Traumatic amputation or severe laceration can result.

Keep hands and feet away from rotating parts.

Tie up long hair and remove jewelry.

Operate equipment with guards in place.

DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught.

Safety Rules

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use electrical cords that are worn, damaged or frayed.

DO NOT operate generator in wet weather.

DO NOT allow children or unqualified persons to operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp areas and areas containing conductive material such as metal decking.

Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system.

WARNING

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it cannot contact the plug.

DO NOT check for spark with the plug removed.

Use only approved spark plug testers.

WARNING

Running engines produce heat.

Severe burns can occur on contact.

Combustible material can catch fire on contact.

DO NOT touch hot surfaces.

Avoid contact with hot exhaust gases.

Allow equipment to cool before touching.

Maintain at least three feet of clearance on all sides to ensure adequate cooling.

Maintain at least five feet of clearance from combustible materials.

Rev CSA41155E-20070416 3

Safety Rules

DANGER

Fuel and fuel vapors are highly flammable and extremely explosive.

Fire or explosion can cause severe burns or death.

Unintentional startup can result in entanglement, traumatic amputation or laceration.

When adding or removing fuel

Turn the generator off and let it cool for at least two minutes before removing the fuel cap.

Loosen the cap slowly to relieve pressure in the tank.

Only fill or drain fuel outdoors in a well-ventilated area.

DO NOT overfill the fuel tank.

Always keep fuel away from sparks, open flames, pilot lights, heat and other sources of ignition.

DO NOT light or smoke cigarettes.

When starting the generator

DO NOT attempt to start a damaged generator.

Make certain that the gas cap, air filter, spark plug, fuel lines and exhaust system are properly in place.

Allow spilled fuel to evaporate fully before attempting to start the engine.

Make certain that the generator is resting firmly on level ground.

When operating the generator:

DO NOT move or tip the generator during operation.

DO NOT tip the generator or allow fuel or oil to spill.

When transporting or servicing the generator:

Make certain that the fuel shutoff valve is in the off position and the fuel tank is empty.

Disconnect the spark plug wire.

When storing the generator:

Store away from sparks, open flames, pilot lights, heat and other sources of ignition.

WARNING

Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go.

Unintentional startup can result in entanglement, traumatic amputation or laceration.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull the starter cord slowly until resistance is felt and then pull rapidly to avoid kickback.

DO NOT start or stop the engine with electrical devices plugged in.

CAUTION

Exceeding the generator’s running capacity can damage the generator and/or electrical devices connected to it

DO NOT overload the generator.

Start the generator and allow the engine to stabilize before connecting electrical loads.

Connect electrical equipment in the off position, and then turn them on for operation.

Turn electrical equipment off and disconnect before stopping the generator.

DO NOT tamper with the governed speed.

DO NOT modify the generator in any way.

CAUTION

Improper treatment or use of the generator can damage it, shorten its life and void your warranty.

Use the generator only for intended uses.

Operate only on level surfaces.

DO NOT expose generator to excessive moisture, dust, or dirt.

DO NOT allow any material to block the cooling slots.

If connected devices overheat, turn them off and disconnect them from the generator.

DO NOT use the generator if:

Electrical output is lost

Equipment sparks, smokes or emits flames

Equipment vibrates excessively

4

Controls and Features

Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.

Generator

Fuel Tank – 6.34 gallon capacity fuel tank.

Oil Filler Cap – Check and fill engine oil level.

Air Cleaner – Protects the engine by filtering dust and debris from the intake air.

Choke – Used to start the engine

Recoil Starter – Used to start the engine

Battery – Used to start the engine.

Fuel Valve – Turn this valve to the “On” position to supply fuel to the engine.

Serial Number – Please have this number available when calling for assistance.

Low Oil Sensor – Senses the level of oil in the crankcase and shuts the engine down if the level falls too low.

Power Panel – See “Power Panel”

Rev CSA41155E-20070416 5

Controls and Features

Power Panel

Receptacles

120 V 30 A Twist-Lock – protected by a 25 A circuit breaker. This receptacle powers 120

Volt AC, 60 Hz, single phase loads requiring up to 30 Amps or 3000 watts of power.

120/240 V 30 A Twist-Lock – protected by a

25 A circuit breaker on each 120 Volt leg of the receptacle. This receptacle powers 240

Volt AC, 60 Hz, single phase loads requiring up to 23 A or 5500 Watts of power. If an

L14-30P plug is wired for only one 120 Volt leg (3-wire connection) then this receptacle powers 120 Volt AC, 60 Hz, single phase loads requiring up to 25 A or 3000 Watts of power.

120 V 20 A Duplex – the duplex is protected by a 20 A circuit breaker. Use the duplex to operate 120 Volt AC, single phase, 60 Hz loads requiring up to 20 A 0r 2400 Watts of power.

12 V 8.3 A DC – this receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cables provided. This receptacle cannot charge 6 Volt batteries and cannot be used to crank an engine. It is not recommended for charging deep cycle batteries. Do no charge batteries for extended periods of time without checking.

Voltmeter – Displays the output voltage of the generator.

Circuit Breakers – Protects the generator against electrical overload.

Keyed Ignition – Turn the key to the

“Start” position to start the generator. Turn to the “Off” position to turn off the generator.

Ground Terminal – Consult an electrician for local grounding regulations.

6

Parts Included

Your C41155CSA Gasoline Powered Generator ships with the following parts:

6 foot Battery Cable

Wheel Kit

Axle 1

10” Solid Wheel

Vibration Mounts

2 pieces

2 pieces

Bolt Kit

Wheel Retaining Pins 2 pieces

Flat Washers

“O” Washers

2 pieces

2 pieces

Plastic Flat Washers 4 pieces

Cap Screws and Nuts 6 sets

Spark Arrester Kit

Spark Arrester

Cover Plate

1 piece

1 piece

Screws, Lock Washers 2 pieces

Oil Funnel 1 piece piece

Spark Plug Socket 1 piece

Rev CSA41155E-20070416 7

Assembly

Assembly

Your generator requires some assembly.

This unit ships from our factory without oil.

It must be properly serviced with fuel and oil before operation.

If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. Please have your serial number and model number available.

Remove the Generator from the Shipping Carton

1.

Set the shipping carton on a solid, flat surface.

2.

Remove everything from the carton except the generator.

3.

Carefully cut each corner of the box from top to bottom. Fold each side flat on the ground to provide a surface area to install the wheel kit and support leg.

Install the Wheel Kit

CAUTION

The wheel kit is not intended for over-the-road use.

You will need the following tools to install the wheels:

12 mm wrench

Socket wrench with a 12 mm socket

Pliers

1.

Before adding oil to the engine, tip the generator slowly so that the engine side is up.

2.

Slide the axle through both mounting brackets.

3.

Slide a wheel onto the axel.

4.

Place a washer on the end.

5.

Install the cotter pin through the hole on the end of the axle.

6.

Carefully bend the legs of the cotter pin back around the axle.

7.

Repeat steps 3-6 to attach the second wheel.

Install the Support Leg

1.

Attach the rubber vibration mount to the support leg with a cap screw

(M8x20) and lock nut (M8).

2.

Attach the support leg to the generator frame with cap screws (M8x30) and lock nuts (M8).

3.

Tip the generator slowly so that it rests on the wheels and support leg.

Connect the Battery

1.

Place the battery in the battery mounting channel.

2.

Hook one J-bolt through the hole on the bottom left side of the battery mounting channel.

3.

Place a washer on the J-bolt and fasten loosely with the wing nut.

4.

Repeat steps 1-2 for the right side of the battery mounting channel.

5.

Tighten both wing nuts evenly and securely.

6.

Remove the protective cover from the red battery lead.

7.

Attach the red lead to the red terminal on the battery with the cap screw

(M6x20) and secure with the lock washer (M6)

8.

Repeat steps 5-6 for the black battery lead.

Install the Spark Arrester

Insert the spark arrester screen into the muffler outlet. Secure the spark arrester by placing the cover plate over the end of the screen, with the lettering facing outward.

Secure the cover plate with the two screws and lock washers provided with the spark arrester kit.

Add Engine Oil

CAUTION

DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage to the generator as a result of failure to follow these instructions will void your warranty.

1.

Place the generator on a flat, level surface.

8

2.

Remove oil fill cap/dipstick to add oil.

3.

Add 1.16 qt (1.1 L) of oil and replace oil fill cap/dipstick.

4.

Check engine oil level daily and add as needed.

CAUTION

The engine is equipped with a low-oil-shutoff and the will stop when the oil level in the crankcase falls below the threshold level.

NOTE

Check oil often during the break-in period. Refer to the Maintenance section for recommended service intervals.

NOTE

The generator rotor has a sealed, pre-lubricated ball bearing that requires no additional lubrication for the life of the bearing.

Add Fuel

1.

Use clean, fresh, regular unleaded fuel with a minimum octane rating of 85.

2.

DO NOT mix oil with fuel.

3.

Clean the area around the fuel cap.

4.

Remove the fuel cap

5.

Slowly add fuel to the tank. DO NOT overfill. Allow approximately ¼ inch of space for fuel expansion.

6.

Screw on the fuel cap and wipe away any spilled fuel.

Assembly

CAUTION

Use regular unleaded gasoline with a minimum octane rating of 85.

Do not mix oil and gasoline.

Fill tank to approximately ¼” below the top of the tank to allow for fuel expansion.

DO NOT fill fuel tank indoors.

DO NOT fill fuel tank when the engine is running or hot.

DO NOT overfill the fuel tank.

DO NOT light cigarettes or smoke when filling the fuel tank.

Grounding

Your generator must be properly connected to an appropriate ground to help prevent electric shock.

WARNING

Failure to properly ground the generator can result in electric shock.

A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of a length of heavy gauge (12 AWG minimum) copper wire between the generator ground terminal and a copper rod driven into the ground. We strongly recommend that you consult with a qualified electrician to ensure compliance with local electrical codes.

Rev CSA41155E-20070416 9

Operation

Operation

Generator Location

Please consult your local authority. In some areas, generators must be registered with the local utility.

Generators used at construction sites may be subject to additional rules and regulations.

This generator must have at least five feet of clearance from combustible material. Leave at least three feet of clearance on all sides of the generator to allow for adequate cooling, maintenance and servicing.

Place the generator in a well-ventilated area.

DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning generator.

Grounding

The generator system ground connects the frame to the ground terminals on the power panel. The system ground is connected to the AC neutral wire.

Surge Protection

CAUTION

Voltage fluctuation may impair the proper functioning of sensitive electronic equipment.

Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage range and may be affected by momentary voltage fluctuations.

While there is no way to prevent voltage fluctuations, you can take steps to protect sensitive electronic equipment.

1.

Install UL1449, CSA-listed, plug-in surge suppressors on the outlets feeding

your sensitive equipment.

Surge suppressors come in single- or multi-outlet styles. They’re designed to protect against virtually all shortduration voltage fluctuations.

2.

Obtain an Uninterruptible Power

Supply (UPS) device.

Most UPS devices come with a rechargeable battery between the electronic equipment and power supply source. The device buffers the voltage and protects against virtually all shortduration voltage fluctuations.

Starting the Engine

1.

Make certain the generator is on a flat, level surface.

2.

Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.

3.

Turn the fuel valve to the “On” position.

4.

Move the choke lever to the “Choke” position.

5.

ELECTRIC START: Turn the ignition key to the “Start” position and hold until engine starts. If the engine fails to start within five seconds, release the key and wait at least ten seconds before attempting to start the engine again.

6.

RECOIL START: Pull the starter cord slowly until resistance is felt and then pull rapidly

7.

As engine warms up, move the choke lever to “Run”.

NOTE

If the engine starts but does not run, make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold.

Connecting Electrical Loads

1.

Let the engine stabilize and warm up for a few minutes after starting

2.

Plug in and turn on the desired 120 and/or 240 Volt AC single phase, 60 Hz electrical loads.

DO NOT connect 3-phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

DO NOT overload the generator.

10

Stopping the Engine

1.

Turn off and unplug all electrical loads.

Never start or stop the generator with electrical devices plugged in or turned on.

2.

Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator.

3.

Turn the ignition switch to the “Off” position.

4.

Turn the fuel valve to the “Off” position.

Do Not Overload Generator

Capacity

Follow these simple steps to calculate the running and starting watts necessary for your purposes.

1.

Select the electrical devices you plan on running at the same time.

2.

Total the running watts of these items.

This is the amount of power you need to keep your items running.

3.

Identify the highest starting wattage of all devices identified in step 1. Add this number to the number calculated in step

2. Surge wattage is the extra burst of power needed to start some electric driven equipment. Following the steps listed under “Power Management” will guarantee that only one device will be starting at a time.

Power Management

Use the following formula to convert voltage and amperage to watts:

Volts x Amps = Watts

To prolong the life of your generator and attached devices, follow these steps to add electrical load:

1.

Start the generator with no electrical load attached.

2.

Allow the engine to run for several minutes to stabilize.

3.

Plug in and turn on the first item. It is best to attach the item with the largest load first.

4.

Allow the engine to stabilize.

5.

Plug in and turn on the next item.

6.

Allow the engine to stabilize.

7.

Repeat steps 5-6 for each additional item.

Rev CSA41155E-20070416

Operation

NOTE

Never exceed the generator capacity when adding loads.

Wattage Reference Chart

Use the chart to determine approximate wattage requirements for your equipment.

NOTE

Starting watts can exceed three times the running watts. The values in the following table are approximate. Refer to your tool or appliance for actual wattage consumption.

11

Operation

Item

Light Bulb 100W

Essentials

Running

Watts

100

Starting

Watts

Sump Pump

Well Pump 1 HP

Water Heater

Security System

AM/FM Radio

Garage Door Opener 1/2 HP

Battery Charger 12V DC

Heating/Cooling

Air Conditioner 12000 BTU 1700

600

2000

4000

180

300

500

110

1800

4000

600

2500

Furnace Fan 1/3 HP

Home Appliances

1200

Microwave 1000W

Electric Range - One Element

Electric Skillet

1000

1500

1250

Coffee Maker

Clothes Washer

1500

1200

2000

Entertainment

CD/DVD Player 100

VCR 100

Stereo Receiver

Television 27"

PC with 15" Monitor

450

500

800

Job Site

Belt Sander 3"

Bench Grinder 6"

Circular Saw

Compressor 1 1/2 HP

Edge Trimmer

Hand Drill 1/2"

Lawn Mower

Paint Sprayer

Table Saw

1000

700

1500

2500

500

1000

1200

600

2000

1500

1500

1500

2500

500

1000

1800

1200

2000

12

Maintenance

The owner/operator is responsible for all periodic maintenance.

WARNING

Never operate a damaged or defective generator.

WARNING

Tampering with the factory set governor will void your warranty.

WARNING

Improper maintenance will void your warranty.

Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator.

NOTE

For service or parts assistance, contact our help line at 1-877-338-0999.

Engine Maintenance

To prevent accidental starting, remove and ground spark plug wire before performing any service.

Oil

Change oil when the engine is warm. Refer to the oil specification to select the proper grade of oil for your operating environment.

1.

Remove the oil drain plug with a 15 mm socket and extension.

2.

Allow the oil to drain completely.

3.

Replace the drain plug.

4.

Remove oil fill cap/dipstick to add oil.

5.

Add 1.16 qt (1.1 L) of oil and replace oil fill cap/dipstick.

Rev CSA41155E-20070416

Maintenance

6.

Dispose of used oil at an approved waste management facility.

Spark Plugs

1.

Remove the spark plug cable from the spark plug.

2.

Use the spark plug tool that shipped with your generator to remove the plug.

3.

Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition.

4.

Make certain the spark plug gap is 0.7 -

0.8mm (0.028 - 0.031 in.).

5.

Refer to the spark plug recommendation chart when replacing the plug.

6.

Carefully thread the plug into the engine.

7.

Use the spark plug tool to firmly install the plug.

8.

Attach the spark plug wire to the plug.

Air Filter

1.

Remove the snap-on cover holding the air filter to the assembly.

2.

Remove the foam element.

3.

Wash in liquid detergent and water.

Squeeze thoroughly dry in a clean cloth.

4.

Saturate in clean engine oil.

5.

Squeeze in a clean, absorbent cloth to remove all excess oil.

6.

Place the filter in the assembly.

7.

Reattach the air filter cover and snap in place.

13

Maintenance

Spark Arrester

1.

Allow the engine to cool completely before servicing the spark arrester.

2.

Remove the two screws holding the cover plate which retains the end of the spark arrester to the muffler.

3.

Remove the spark arrester screen.

4.

Carefully remove the carbon deposits from the spark arrester screen with a wire brush.

5.

Replace the spark arrester if it is damaged.

6.

Position the spark arrester in the muffler and attach with the two screws.

Cleaning

CAUTION

DO NOT spray engine with water.

Water can contaminate the fuel system.

Use a damp cloth to clean exterior surfaces of the engine.

Use a soft bristle brush to remove dirt and oil.

Use an air compressor (25 PSI) to clear dirt and debris from the engine.

Adjustments

The air-fuel mixture is not adjustable.

Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at 1-877-338-0999 for all other service and/or adjustment needs.

Maintenance Schedule

Follow the service intervals indicated in the schedule below.

Service your generator more frequently when operating in adverse conditions.

Contact our help line at 1-877-338-0999 to locate the nearest Champion Power

Equipment certified service dealer for your generator or engine maintenance needs.

Every 8 hours or daily

Check oil level

Clean around air intake and muffler

First 5 Hours

Change oil

First 10 hours

Check/Adjust Valve Clearance *

Every 50 hours or every season

Clean air filter

Change oil if operating under heavy load or in hot environments

Every 100 hours or every season

Change oil

Clean/Adjust spark plug

Check/Adjust valve clearance *

Clean spark arrester

Clean fuel tank and filter *

Every 3 years

Replace fuel line

* To be performed by knowledgeable, experienced owners or Champion Power

Equipment certified service dealers

Generator Maintenance

Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, dirt, moisture or corrosive vapors.

CAUTION

DO NOT use a garden hose to clean the generator.

Water can enter the generator through the cooling slots and damage the generator windings.

Use a damp cloth to clean exterior surfaces of the generator.

Use a soft bristle brush to remove dirt and oil.

Use an air compressor (25 PSI) to clear dirt and debris from the generator.

Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.

14

Storage

The generator should be started at least once every 14 days and allowed to run for at least

20 minutes. For longer term storage, please follow these guidelines.

Engine Storage

1.

Allow the engine to cool completely before storage.

2.

Clean the engine according to the instructions in the Maintenance section.

3.

Drain all fuel completely from the fuel line and carburetor to prevent gum from forming.

4.

Add a fuel stabilizer into the fuel tank.

Storage

5.

Change the oil.

6.

Remove the spark plug and pour about

½ ounce of oil into the cylinder. Crank the engine slowly to distribute the oil and lubricate the cylinder.

7.

Reattach the spark plug.

Generator Storage

1.

Allow the generator to cool completely before storage.

2.

Turn off the fuel supply at the fuel valve.

3.

Clean the generator according to the instructions in the Maintenance section.

4.

Store the unit in a clean, dry area.

5.

Store in a clean, dry place out of direct sunlight.

Rev CSA41155E-20070416 15

Specifications

Specifications

Spark Plugs

Engine Specifications

Engine

Without Wheels

Height

Width

Length

With Wheels

Height

Width

Length

11 HP OHV CPE

EPA & CARB certified

Generator Specifications

Running Wattage

Starting Wattage

AC Load

DC Load

5500 Watts

6500Watts

120/240 V

12 V

Hz

6.34 gallons (24 L)

218.25 lbs. (99 kg)

22 inches (55.88 cm)

21 inches (53.34 cm)

27.5 inches (68.95 cm)

25.25 inches (64.14 cm)

27 inches (68.58 cm)

28.5 inches (72.39 cm)

Your generator comes equipped with a ¾” long reach plug (14mm)

Intermittent use (less than 1 hour/month) or colder temperatures (below 60°F)

NGK B6ES or equivalent

Moderate use (less than 3 hours/month) or seasonal temperatures (50-80°F)

NGK B7ES or equivalent

Extreme use (continuous) or hot climates

(80-100°F)

Frequency 60

Fuel Capacity

Weight

NGK B8ES or equivalent

Make certain the spark plug gap is 0.7 -

0.8mm (0.028 - 0.031 in.).

Valve Clearance

Intake 0.13-0.17mm (0.005 – 0.007 in.)

Exhaust 0.18-0.22mm (0.007 – 0.009 in.)

Fuel

Fuel capacity is 6.34 US gallons (24 L). Use regular unleaded gasoline with a minimum octane rating of 85.

Oil

Oil capacity is 1.16 qt (1.1 L).

16

Parts Diagram

Specifications

Rev CSA41155E-20070416 17

Specifications

Parts List

Item Part Number

1 ST188FD-1713000

2 ST188FD-1710100-CSA

3 ST04FD-1151202-CSA

4 ST05FD-1151204-CSA

5

6

ST188FD-1710001-CSA

ST188FD-1710002-CSA

7 ST188FD-1710003-CSA

8 ST168FD-1710004

9 ST05FD-1151208-M

10

11

ST02FD-1151202A-CSA

ST05FD-1151207-CSA

12 GB5781-B5-10

13 ST05FD-1152002

14 GB5781-B6-10

15 ST168F-1152032-CSA

16 ST168F-1152004A

17 ST05F-1152031-CSA

18 ST05FD-1152035-CSA

19 ST05FD-1152032

20 GB5789-B6-164

21 ST04FD-1152001

22 GB5789-FB10-1.25-250

23 ST04FD-1152020-CSA

24 ST04FD-1152010-CSA

25 ST05FD-1151600

26 ST188FD-1030011

27 ST1P60F-1030004

28

29

ST188F-1030003

ST182FD-1000000G

30 ST182FD-1742002-CPE

31 ST182FD-1742001-UC

32 ST182FD-1742002-UC

33 ST05FD-1151300A

34 ST05FD-1151300B

35 GB41-N-10

36 ST188FD-1740001-K

37 ST182FD-1742100-UC

38 ST160F-1070001-1

39 ST188FD-1160002

40 ST168FD-1160400

41 ST188FD-1160001

42 ST168F-1160500

43 ST168FD-1160200

44 GB1667-S5-6

45 ST168FD-1160100

46 GB5781-B6-25

47 GB90-W-6

48 ST168FD-1163000

49 ST188FD-1131001

50 ST188FD-1131015

51 ST188FD-1131100

52 ST188FD-1131002

53 GB1667-S5-10

54 ST188FD-1031200

Description

Keyed Ignition Switch

20 Amp Circuit Breaker

Receptacle L6-20R

Receptacle L14-20R

Red Positive Terminal

Black Negative Terminal

10 Amp Circuit Breaker

Wiring Control Box

Generator End Cover

Terminal

AVR

Flange Bolt M6×164

Flange Bolt M10×1.25×250

O-Ring

Oil Filler Cap

11.0 HP Generator Engine

Control Protector

Handle

Pin

Axle

Frame

Fuel Tank Cap

Fuel Meter Assembly

One Way Valve

2

2

2

2

2

4

1

1

6

1

1

1

1

1

2

1

4

4

4

1

1

1

1

2

1

7

1

1

1

1

1

4

1

1

1

1

1

1

1

1

1

Qty

1

1

1

1

1

1

1

1

1

1

1

1

2

1

18

Item Part Number

55 ST182FD-1130002

56 ST188FD-1131000

57 ST188F-1020001

58 ST182FD-1133000-CPE

59 ST188FD-1134000

60 ST182FD-1130003

61 ST188FD-1010002

62

63

64

ST188FD-1090006

ST188FD-1090100

ST188FD-1090002

65 GB41-N-5

66 ST188FD-1090003

67 ST188FD-1090004

68 ST188FD-1090200

69 GB41-N-6

70 ST188FD-1080200

71 ST188FD-1010001

72 ST188FD-1100001

73 ST188FD-1730001

74 GB5781-B8-20

75 ST188FD-1730100

76 ST188FD-1732200-A

77 GB57814-B6-12

78 ST188FD-1731000A

79 ST188FD-1730002A

80 ST188FD-1732001

81 ST188FD-1732101

82 GB5781-B8-30

83 ST188FD-1740004-C

84 ST188FD-1743001-T

85 ST182FD-1742001-CPE

86 ST188FD-1744002-D

87 GB90-W-16

88 GBT91-CP3.2-40

89 GB41-N-6

90 ST188FD-1700210-C

91 GB41-N-8

98

99

100

101

102

103

92 FM12180

93 ST188FD-1700203-C

94 ST188FD-1700200-C

95 GB5781-B8-50

96 ST168FD-1100201

97 ST04FD-1151220-CSA

ST05FD-1719000-CSA

GB5781-B6-40

ST05FD-1151206

ST05FD-1170003-B

ST05FD-1151209-CSA

ST02FD-1151201

104

105

ST188FD-1750002-C1

ST188FD-1750002-C2

106 ST188FD-1751002

107 ST168FD-11511013G

108 ST188F-1110007

109 ST182FD-1742002-UC

Description

Grommet

Carburetor

Carburetor Insulator Packing

Air Cleaner Stay

Air Cleaner Case Complete

Air Cleaner Seal

Separator

Element

Air Cleaner Cover Complete

Muffler Outer Protector

Muffler

Bushing ø 8.5

Muffler Inner Protector

Fuel Tank Wings

Wheel

Washer ø 16

Cotter Pin 3.2×40

Battery Setting Plate

Battery

Spark Arrester Assembly

30A Double Throw Breaker

Relay

Bolt M6×40

Grommet

Grommet

Conduit

Grommet

Red Positive Battery Lead

Black Negative Battery Lead

Specifications

1

3

1

1

1

1

1

2

1

2

1

1

2

1

2

2

1

2

2

2

2

2

1

6

1

1

3

1

4

2

1

4

1

2

1

1

7

1

1

22

1

Qty

3

1

1

1

1

1

2

1

1

1

6

1

1

Rev CSA41155E-20070416 19

Specifications

Wiring Schematic

20

Troubleshooting

Troubleshooting

Problem

Generator will not start

Generator will not start;

Generator starts but runs roughly

Cause

No fuel

Faulty spark plug

Unit loaded during start up

Low oil level

Generator shuts down during operation

Choke in the wrong position.

Spark plug wire loose

Out of fuel

Low oil level

Generator cannot supply enough power or overheating

Generator is overloaded

Insufficient ventilation

No AC output

Generator gallops

Repeated circuit breaker tripping

Cable not properly connected

Connected device is defective

Circuit breaker is open

Capacitor defective

Faulty brush assembly

Faulty AVR

Loose wiring

Other

Engine governor defective

Overload

Faulty cords or device

Solution

Add fuel

Replace spark plug

Remove load from unit

Fill crankcase to the proper level

Place generator on a flat, level surface

Adjust choke.

Attach wire to spark plug

Fill fuel tank

Fill crankcase to the proper level.

Place generator on a flat, level surface

Review load and adjust. See “Power

Management”

Check for air restriction. Move to a well ventilated area

Check all connections

Replace defective device

Reset circuit breaker

Replace capacitor (Service Center)

Replace brush assembly (Service

Center)

Replace AVR (Service Center)

Inspect and tighten wiring connections

Contact the help line.

Contact the help line

Review load and adjust. See “Power

Management”

Check for damaged, bare or frayed wires. Replace defective device

Rev CSA41155E-20070416 21

Warranty

Warranty

CHAMPION POWER EQUIPMENT

1 YEAR LIMITED WARRANTY

Effective September 1, 2006. Replaces all undated warranties and all warranties dated before September 1, 2006.

Warranty Qualifications

Champion Power Equipment (CPE) will register this warranty upon receipt of your

Warranty Registration Card and a copy of your sales receipt from one of CPE's retail locations as proof of purchase.

Please submit your warranty registration and your proof of purchase within ten (10) days of the date of purchase.

Repair/Replacement

Warranty

CPE warrants to the original purchaser that the mechanical and electrical components will be free of defects in material and workmanship for a period of one (1) year from the original date of purchase (90 days for commercial & industrial use).

Transportation charges on product submitted for repair or replacement under this warranty are the sole responsibility of the purchaser. This warranty only applies to the original purchaser and is not transferable.

Do not return the unit to the place of purchase

Contact CPE's Technical Service and CPE will troubleshoot any issue via phone or email. If the problem is not corrected by this method, CPE will, at its option, authorize evaluation, repair or replacement of the defective part or component at a CPE

Service Center. CPE will provide you with a case number for warranty service. Please keep it for future reference. Repairs or replacements without prior authorization, or at an unauthorized repair facility, will not be covered by this warranty.

Warranty Exclusions

This warranty does not cover the following repairs and equipment:

Normal Wear

Generators need periodic parts and service to perform well. This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a whole.

Installation, Use and

Maintenance

This warranty will not apply to parts and/or labor if this generator is deemed to have been misused, neglected, involved in an accident, abused, loaded beyond the generator’s limits, modified, installed improperly or connected incorrectly to any electrical component. Normal maintenance such as spark plugs, air filters, adjustments, fuel system cleaning and obstruction due to buildup is not covered by this warranty.

Other Exclusions

This warranty excludes:

Cosmetic defects such as paint, decals, etc.

Wear items such as filter elements, o-rings, etc.

Accessory parts such as starting batteries, and storage covers.

Failures due to acts of God and other force majeure events beyond the manufacturer’s control.

Problems cause by parts that are not original

Champion Power Equipment parts.

This warranty does not apply to generators used for prime power in place of a utility.

Limits of Implied Warranty and Consequential Damage

Champion Power Equipment disclaims any obligation to cover any loss of time, use of this product, freight, or any incidental or consequential claim by anyone from using this generator. THIS WARRANTY IS IN

LIEU OF ALL OTHER WARRANTIES,

EXPRESS OR IMPLIED, INCLUDING

WARRANTIES OF MERCHANTABILITY

OR FITNESS FOR A PARTICULAR

PURPOSE

22

A unit provided as an exchange will be subject to the warranty of the original unit.

The length of the warranty governing the exchanged unit will remain calculated by reference to the purchase date of the original unit.

This warranty gives you certain legal rights which may change from state to state. Your state may also have other rights you may be entitled to that are not listed within this warranty.

Contact Information

Address

Champion Power Equipment, Inc.

Customer Service

10006 Santa Fe Springs Rd.

Santa Fe Springs, CA 90670

Customer Service

Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)

Toll Free: 1-877-338-0999

Fax no.: 1-562-236-9429

Technical Service

Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)

Toll Free: 1-877-338-0999 [email protected]

Warranty

Rev CSA41155E-20070416 23

Notes

Notes

24

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • 41155 produces alternating current (AC)
  • powered by a gasoline engine
  • low oil shutdown to protect the engine
  • circuit breaker to prevent overloading
  • GFCI outlet to protect users from electrical shock
  • comes with a variety of accessories

Related manuals

Frequently Answers and Questions

What safety precautions should be taken when operating the generator?
Operate the generator outdoors in a well-ventilated area, keep it at least three feet away from combustible materials, and never operate it inside a building or compartment.
What type of fuel does the generator use?
The generator runs on unleaded gasoline with a minimum octane rating of 87.
How often should the oil be changed?
The oil should be changed every 50 hours of operation or every six months, whichever comes first.
What is the generator's rated wattage?
The generator has a rated wattage of 4000 watts and a maximum wattage of 4500 watts.
What kind of maintenance does the generator require?
Regular maintenance includes changing the oil, cleaning the air filter, and replacing the spark plug.
How long can the generator run continuously?
The generator can run continuously for up to 12 hours at a 50% load.