- Home
- Domestic appliances
- Small kitchen appliances
- Coffee makers
- Cecilware
- BT2A 2 Station Pourover - Brew Time Coffee Brewers
- Operation manual
advertisement
▼
Scroll to page 2
of 7
BREW TIME COFFEE BREWERS OPERATION MANUAL SPECIFICATIONS INSTALLATION INSTRUCTIONS BREWING INSTRUCTIONS CLEANING INSTRUCTIONS ADJUSTMENT INSTRUCTIONS TROUBLE SHOOTING GUIDE REPAIR PARTS LIST WIRING DIAGRAM WARRANTY Every Cecllware product has been carefully inspected before shipment The finest of materials and ihe highest standards of workmanship have been built in to the equipment. Within 1 year of purchase, should any Cecilware product show defect in factory workmanship or material, we agree io repair, at our option or replace without cost to user such parts which prove upon factory inspection lo have been so defective. All equipment mus! be shipped transportalion charges prepaid for acceptance. This warranty covers replacement paris only, labor charges are covered for 90 days after installation This warranty does nol apply under the following conditions: * neglect or abuse of equipment * excessive lime condition * improper installation * any oulside modification to equipment Every Cecilware um body is covered for three years. This warranty covers the stainless steel body and stainless sled liners only. Portable equipment such as Electric Fryers, Food Warmers, Electric Stoves, Dispensers, Plug-in Urns, Coffee Brewers and Warmers must be returned to the factory or brought 10 an authorized service station for repair BT 3 MODEL # GENERAL SPECIFICATIONS ELECTRICAL DATA Ship wt. Width | Depth | Height | (Ibs) | Watts | Volts | Amps 1600 120 13.3 BT2 - 2 Station Pourover 17%" 9%” 20%" 26 2200 220 10.0 1600 120 133 BT2A - 2 Station Automatic 17%" 9%" 20%” 26 2200 220 10.0 1700 120 14.2 BT3 - 3 Station Pourover 17%" 9%" 20%" 27 2300 220 10.5 1700 120 14.2 ВТЗА - 3 Station Automatic 17%" 9%" 20%" 27 2300 220 10.5 WARNING: MACHINE WARRANTY I S VOID IF MACHINE IS CONNECTED TO ANY VOLTAGE OTHER THAN 120 VOLTS. (EXPORT UNITS SHOULD BE CONNECTED TO 220 VAC VOLTS.) **INSTALLATION INSTRUCTIONS** A SEPARATE CIRCUIT SHOULD BE SUPPLIED FOR EACH OF THESE BREWERS WITH A 15 AMP. CIRCUIT BREAKER OR FUSE. CHECK LOCAL CODES FOR COMPLIANCE IN NOTE: CAUTION: INSTALLATION. DO NOT CONNECT BREWER TO POWER SOURCE UNTIL AFTER PRIMING. (INSTRUCTION BELOW.) CECILWARE CORPORATION 43-05 20th Avenue, Long Island City, NY 11105 2551 Fernwood Avenue, Lynwood, CA 90262 N203A-1/95 1 WARNING: MACHINE WARRANTY IS VOID IF MACHINE IS CONNECTED TO ANY VOLTAGE OTHER THAN 120 VOLTS. (EXPORT UNITS SHOULD NNECTED TO 220 **INSTALLATION INSTRUCTIONS** NOTE: A SEPARATE CIRCUIT SHOULD BE SUPPLIED FOR EACH OF THESE BREWERS WITH A 15 AMP. CIRCUIT BREAKER OR FUSE. CHECK LOCAL CODES FOR COMPLIANCE IN INSTALLATION. CAUTION: DO NOT CONNECT TO POWER SOURCE UNTIL AFTER PRIMING (INSTRUCTION BELOW). WATER HOOK-UP (FOR AUTOMATIC BREWERS ONLY - BT2A, BT3A) Automatic Brewers should be hooked up by a plumber in compliance with local plumbing codes. The National Sanitation Foundation (NSF) requires the following for NSF approved hook-up: 1. A quick disconnect water connection or enough extra coiled tubing, (at least two times of the depth of brewer) so that brewer can be moved fo clean undemeath. 2. An approved flowback prevention device such as a double check valve to be installed between brewer and water supply. You automatic coffee brewer was shipped with a water hook-up kit consisting of a strainer, length of %" (outside diameter) copper tubing and water valve fitting which connects to valve in rear of brewer. This fitting needsd to be finger tightened only. Connect the open end of the strainer to %" O.D. tubing and a shut-off (supplied by others) leading to cold water supply. 20-120 PSI water pressure, required for proper operation. CAUTION: These brewers are equipped with a rear Toggle Switch which controls the power supply to the Brewer. Toggle Switch must be in the down or “OFF” position until step (3) is completed. TO PRIME THESE INSTRUCTIONS ARE FOR INITIAL PRIMING ONLY AND DO NOT HAVE TO BE REPEATED FOR NORMAL OPERATION. 1. Remove sample filter pack from funnel and insert funnel back into machine. 2. Place an empty decanter on warmer plate directly under funnel. 3. Lift cover (69 Fig. 3) and pour 3 decanters of cold water through the top opening at 3 minute intervals. After the third decanter is poured, water will flow through spray head and funnel and fill decanter beneath. 4. Plug line cord into receptacle and tum on power switch. The power light will light, indicating power is applied to the tank heater, Wait approximately 15 minutes for the water to reach brewing temperature, at which point the green light will light. You are now ready to brew coffee. **BREWING INSTRUCTIONS** AUTOMATIC MODELS BT2A, BT3A 1. Make sure power switch and green ready light are on. (Wait for green ready light to come on if necessary). 2. Place paper filter in brew funnel. Open pack of fine grind coffee (as recommended by your coffee supplier) and spread evenly on filter paper. 3. Insert Brew funnel back into machine and place empty decanter under funnel. 4. Tum on warmer switch and press brew switch. Coffee will be ready in 3% minutes. 5. Adjust timer (if necessary to fill decanter to just below band on handle)refer to instructions for timer adjustment). 6. Remove grounds and filter as soon as coffee has dripped through. Never pour coffee back through spent grounds. POUR-OVER MODELS (BT2, BT3) 1. Follow steps 1, 2 and 3 above. 2. Fill decanter with cold water to just below band on handle, lift cover (69, Fig.3), and pour water through top of screened opening. Place empty decanter under funnel. 3. Tum on left warmer switch above decanter. Coffee will be ready in 3% minutes. 4. Remove grounds and filter as soon as coffee has dripped through. Never pour coffee back through spent grounds. BACK-UP SYSTEM (FOR AUTOMATIC BREWERS) In case of solenoid or timer malfunction or water supply problems (clogged strainer), automatic models may be usedf as pourover units simply by lifting cover and pouring decanter through screened top opening. **CLEANING INSTRUCTIONS** 1. Wash brew funnel and decanter by hand as needed. Do not use dishwasher, which may cause decanter breakage. 2. For cleaning all metal surfaces, use any reputable stainless steel cleaning compound. Sprayhead should be checked and cleaned regularly. (Al least once a week.) Sprayhead holes must be kept open. To prevent “LIMING" problems in the water tube and air tube, remove sprayhead and insert spring probe all the way into the tank through both tubes. When inserted into tank properly, no more than two inches of the spring should be visible. Push back and forth five or six times. This will keep tubes open and clear of lime. In hard water areas, this should be done every day; this takes less than a minute. FOR AUTHORIZED SERVICE PERSONNEL ONLY **SERVICE INSTRUCTIONS** and **TROUBLE SHOOTING GUIDE** CAUTION: DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL REPAIRS THERMOSTAT ADJUSTMENTS: NOTE: The thermostat adjustment knob (fem 15) is located in back of top box. If water temperature is less than 197°F (92°C) slowly tum thermostat knob clockwise until ready light goes out. When temperature of water approaches 197° to 203°F (92° to 95°C) slowly turn thermostat knob counter-clockwise until the green ready light comes on. If water temperature cannot be increased when thermostat knob is tumed fully clockwise, then proceed as follows: Remove Bracket and pull off knob. Place a small screwdriver into the center of thermostat shaft. While observing green ready light and temperature on thermometer. hold shaft and tum small adjustment screw in center counter-clockwise until green ready light goes out. When temperature of water approaches 197°-203°F (92°-85°C), slowly tur screw clockwise until ready light comes on. Tuming screw clockwise lowers temperature; counter-clockwise raises it. After adjusting center screw, place nail polish or glyplol on screw to set in i NOTE: As a final check, measure water temperature at Spray Head (25, Fig 3). Temperature should be 197° to 203°F (92° to 95°C). TIMER ADJUSTMENTS (Automatic Models BT2A, BT3A) NOTE: Timer adjustment knob is located in back of top box. To increase volume of water, tum knob of timer clockwise. To decrease, tum knob counter-clockwise. Turn knob by small increments. NOTE: Timer must go through a complete cycle before another adjustment can be made. Timer cannot be adjusted once it has been initiated. PROBLEMS WITH WARMER ELEMENTS & SWITCHES: If warmer plate fails to heat, first check power source and then check if light on warmer switch (21 Fig 3) is lit when in the “1" position. If warmer swilch is lit, replace warmer plate by unplugging brewer, removing the two hold down screws on plate and withdrawing warmer plate from brewer. Replace the new warmer plate. If warmer switch does not light, replace it. To remove switch press each tab behind front plate of brewer down with screwdriver in tum. As each tab is pressed, pop that corner of warmer switch out of the front of brewer. New switch snaps in from the front. IF WATER FAILS TO HEAT: 1. Red power light (20 Fig 3) and warmer switches do not come on, check power source. Replace fuse or reset circuit breaker if necessary. If power is good, check rear power switch for continuity and replace if switch stays open. 2. If water still fails to heat, disconnect line cord and check out tank heater (31 Fig 3), thermostat (14 Fig 3) and high temperature safety shutoff (54 Fig 3). Replace needed parts. : MAINTENANCE ON AUTOMATIC MODELS BT2A, BT3A IF NO WATER COMES FROM SPRAY HEAD AND POWER TO BREWER IS PRESENT CHECK: 1. Water Supply Line 2. Strainer/Filter 3. Solenoid 4. Timer TESTING SOLENOID AND TIMER Make sure brewer s property primed. Tum on power swich and then warmer switch above funnel. Press brew switch and hold for one minute. f solenoid buzzes and water flows through spray head when brew Switch s pressed and held, but siops when switch is released, timer is defective. Replace i. If no water flows from spray head, and solenoid is inactive, frst check brew switch and wiring to solenoid and replace as necessary. if brew switch and wiring are okay, solenoid is at fault REPLACING SOLENOID, TIMER, HI-LIMIT, THERMOSTAT AND TANK HEATER (See III. 3) Unplug power cord, shut off water supply (for automatic brewers) and remove top cover. Solenoid (Нет 1)- Remove electrical connections, (2) screws, water inlet fitting and silicone tubing. Replace with new solenoid. Timer (item 13) - Loosen and remove (2) screws in back of top box. Lift out imer and disconnect the color coded wires one by one and connect same lo replacement timer. Place pointer of knob to center and dial range. Hi-Limit Switch (Item 54)- Disconnect the (2) push-on leads, loosen large nut on heating element terminal and pull out hi-limit bracket (hem 53). Replace swilch (em 54), Thermostat (Item 16)- Remove water tank insert (item 40), thermstat bulb clip (em 48), hex nut (Hem 42) from capillary tank fitting, thermostat knob guard (Hem 14), and (2) screws securing thermostat fo housing. Disconnect the push-on leads and remove thermostat. Replace with new one in reverse order. When installing new control, do nol overtighten small packing nut on compression fitting. Tank Heater (ltem 32) Remove tank insert (tem 40), bulb clip (em 48), (2) hex nuts and washers. Disconnect push-on leads. Replace in reverse order. = a Line Cord Switch LOG9A c99Na OFF EN goon | | pe Top Wormer 8 Switch RETA I for BT 3 only | | e | ь — a] LISSA | : E Di | | E G231A | ' , Werner I120V 400 W | Yee | Г o io | I - LA -——— T == Reody ligh mi ia L289A | DUDE | o E a BROWN —--—— >» — Г Switeh for right RED: Su, fom bent =~ ma ; bottom Wormar "om Mar = LISSA 63 lo Не E e = — N207A WIRING DIAGRAM FOR BT3 Fig.1 REPLACEMENT PARTS LIST FOR BT SERIES BREWERS Мет # Description Part 4 Where Used tem # Description Part # Where Used 1 Solenoid Valve L298A All Automat : нд" 40 Water Tank Insert Q141Q BT2A BT3A 2 pais Screen #10 x % “A PO50A All Automat 40 Water Tank Insert Q1340 BT2, BT3 rg 41 Tank Cover Gasket M215A 3 Solenoid Fitting Gasket MIB2R Al Autgmt 42 Yax 18% Hex nut- BT K207A 4 Solenoid Fitting K178A All Automat 47 Water Inlet Tub H168V 5 Solenoid Tinnerman P228A All Automat P143A All Automatic 8 Switch Guard US65V * — TRATO 200 9 Heater on/off switch LO69A т tal U623A 10 Filling Hose M222J — All Automat = sous 11 Hose Clamp P216A All Automat 12 #6-32 x Ya Screw P183A 13 Solid State Timer L265A All Automat 49 Water Tank Q133A BT2, BT3 15 Thermostat Knob MOOBA 49 Water Tank Q140A BT2A 3A 16 Thermostat LOO2A 50 Stainless Steel Washer P175A 17 #8-32 x % Screw PO12A 51 Spray Head Gasket M121A 19 4%" Grommet M218A 52 #6-32 Tinnerman POBBA 20 Red Power Light C260A 53 Hi-Limit Bracket U556E 21 Warmer Switch L155A 54 HiLimit L267A 22 Brew Switch L291A All Automat 61 Heyco Bushing BO12A Brew Ready Light L289A BT2,3 62 Line Cord C9980 24 Spray Head Adapter E007 63 Warmer Element Assembly GO95A 25 Spray Head EO26A 64 #6-32 x % Screw P139A funnel 66 Warmer Spacer P205A BT 3,3A 26 Funnel Runner (Left) w/VOO4A USB4A 87 %" Grommet MO90A funnel 68 Pour-Over Dish US87Q 27 Funnel Runner (Right) w/VOO4A USB5A 69 Cover Assembly Us38Q 27 Funnel Runner (Right) w/VOOOA US62A 71 Chain P291A funnel 28 Bottom Cover R393A 20 Rubber Foot M134A 30 Mounting Screw #6-32 x % P271A "NOT SHOWN 31 318 x Ya Brass FTG KO38A MO Cecilware Funnel (Standard) VOOOA 32 Tank Heater 1400W @ 120V G231A Biack 33 Overlow Tube H164A Brewmatic Funnel (Small) VOO4A 34 Hose Clamp P223A Filter Paper for A-12 = Spray Tub - 2PC es es Filter Paper for A-10 op Cover . ing (Small V161A us R402V BTS 3A Clean Out Spring ( ) К a | AA E CA ws SR) | k | ИГ. DO ALA e ds e Li DOE BT 3 (shown) ; | VON Fig. 3 "—-=c©@ sno (J114) ELECTRICAL SCHEMATIC FOR BT BREWERS SYM. | Part Description P/N DS1 | Power Light C260A K1 Solenoid L298A K2 | Timer Relay L265A R1 Tank Heater G231A W1 | Left Warmer GO97A W2 | Right Warmer GO97A W3 | Top Warmer BT3, BT3A GO97A 51 Main Power Switch LO69A 53 Brew Cycle Control L155A & Left Warmer Swilch S4 | Right Warmer Swilch L155A 55 | Brew Switch BT2A, BT3A | L291A S6 | Hi-Limit Switch L267A S7 | Thermostat L266A 100-203 Degree F BL Black Wire WH | White Wire BR Brown Wire Red | Red Wire | Blue | Blue Wire | Omit the following parts on BT2 and BT3 Units: K1. K2. 55 (Pins *1 and #2) ELECTRICAL SCHEMATIC FOR BT BREWERS — THERMOSTAT TIMER WITHOUT WATER TAP CONNECT 2804 wing (1) TO TIER (TERMAL LY) — == STL-24 00 | == L a BTL-2AWT OD E (О | " A = == || e ¡es 1 | TERMINAL ! du ñ шей 8 a 231 A 1400 W @ 20V | ; 1 | ' | " | POWER " SWITCH | Z L 181 A | в | ” LE e ——] a > Hi o. ura — ll 100 W@ 120 v 100 W(D IZO Y WARMER A | — WHITE ME — BLACK WIRE — BW WIRE FIG. 1 16 KW @ 120V 50/60 HZ N 207 A WT НЕО м As a 6 Zo #5 5 Oz = ss = 5 æs de EF o Е = Ds E = BREW BREW READY SWITCH LIGHT LIBEA LISTA WARMER CORT A 100 ww (D IZO Y SWITCH LISCA NEO WIRE LINE CORD — WHITE WIRE — ONEEN WINE — BLACK WIRE 213, ST 3A, BT SANT —— mue une @ 50/60 HZ cui A cite 1.7 KW 120 \ FIG. © - 11/15/65 N 208 A
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project