Cecilware BT2 Operation Manual | Manualzz
BREW TIME
COFFEE BREWERS
OPERATION MANUAL
SPECIFICATIONS
INSTALLATION INSTRUCTIONS
BREWING INSTRUCTIONS
CLEANING INSTRUCTIONS
ADJUSTMENT INSTRUCTIONS
TROUBLE SHOOTING GUIDE
REPAIR PARTS LIST
WIRING DIAGRAM
WARRANTY
Every Cecllware product has been carefully inspected before shipment The finest of materials and ihe highest
standards of workmanship have been built in to the equipment.
Within 1 year of purchase, should any Cecilware product show defect in factory workmanship or material, we agree io
repair, at our option or replace without cost to user such parts which prove upon factory inspection lo have been so
defective. All equipment mus! be shipped transportalion charges prepaid for acceptance. This warranty covers
replacement paris only, labor charges are covered for 90 days after installation
This warranty does nol apply under the following conditions:
* neglect or abuse of equipment
* excessive lime condition
* improper installation
* any oulside modification to equipment
Every Cecilware um body is covered for three years. This warranty covers the stainless steel body and stainless sled
liners only.
Portable equipment such as Electric Fryers, Food Warmers, Electric Stoves, Dispensers, Plug-in Urns, Coffee Brewers
and Warmers must be returned to the factory or brought 10 an authorized service station for repair
BT 3
MODEL # GENERAL SPECIFICATIONS ELECTRICAL DATA
Ship wt.
Width | Depth | Height | (Ibs) | Watts | Volts | Amps
1600 120 13.3
BT2 - 2 Station Pourover 17%" 9%” 20%" 26 2200 220 10.0
1600 120 133
BT2A - 2 Station Automatic 17%" 9%" 20%” 26 2200 220 10.0
1700 120 14.2
BT3 - 3 Station Pourover 17%" 9%" 20%" 27 2300 220 10.5
1700 120 14.2
ВТЗА - 3 Station Automatic 17%" 9%" 20%" 27 2300 220 10.5
WARNING: MACHINE WARRANTY I
S VOID IF MACHINE IS CONNECTED TO ANY VOLTAGE OTHER
THAN 120 VOLTS. (EXPORT UNITS SHOULD BE CONNECTED TO 220 VAC VOLTS.)
**INSTALLATION INSTRUCTIONS**
A SEPARATE CIRCUIT SHOULD BE SUPPLIED FOR EACH OF THESE BREWERS WITH A
15 AMP. CIRCUIT BREAKER OR FUSE. CHECK LOCAL CODES FOR COMPLIANCE IN
NOTE:
CAUTION:
INSTALLATION.
DO NOT CONNECT BREWER TO POWER SOURCE UNTIL AFTER PRIMING. (INSTRUCTION
BELOW.)
CECILWARE CORPORATION 43-05 20th Avenue, Long Island City, NY 11105
2551 Fernwood Avenue, Lynwood, CA 90262
N203A-1/95
1
WARNING: MACHINE WARRANTY IS VOID IF MACHINE IS CONNECTED TO ANY VOLTAGE
OTHER THAN 120 VOLTS. (EXPORT UNITS SHOULD NNECTED TO 220
**INSTALLATION INSTRUCTIONS**
NOTE: A SEPARATE CIRCUIT SHOULD BE SUPPLIED FOR EACH OF THESE BREWERS WITH A 15 AMP.
CIRCUIT BREAKER OR FUSE. CHECK LOCAL CODES FOR COMPLIANCE IN INSTALLATION.
CAUTION: DO NOT CONNECT TO POWER SOURCE UNTIL AFTER PRIMING (INSTRUCTION BELOW).
WATER HOOK-UP (FOR AUTOMATIC BREWERS ONLY - BT2A, BT3A)
Automatic Brewers should be hooked up by a plumber in compliance with local plumbing codes. The National Sanitation Foundation (NSF) requires the following for NSF
approved hook-up:
1. A quick disconnect water connection or enough extra coiled tubing, (at least two times of the depth of brewer) so that brewer can be moved fo clean undemeath.
2. An approved flowback prevention device such as a double check valve to be installed between brewer and water supply.
You automatic coffee brewer was shipped with a water hook-up kit consisting of a strainer, length of %" (outside diameter) copper tubing and water valve fitting which connects
to valve in rear of brewer. This fitting needsd to be finger tightened only. Connect the open end of the strainer to %" O.D. tubing and a shut-off (supplied by others) leading to
cold water supply. 20-120 PSI water pressure, required for proper operation.
CAUTION: These brewers are equipped with a rear Toggle Switch which controls the power supply to the Brewer. Toggle Switch must be in the down or “OFF” position
until step (3) is completed.
TO PRIME THESE INSTRUCTIONS ARE FOR INITIAL PRIMING ONLY AND DO NOT HAVE TO BE REPEATED FOR NORMAL
OPERATION.
1. Remove sample filter pack from funnel and insert funnel back into machine.
2. Place an empty decanter on warmer plate directly under funnel.
3. Lift cover (69 Fig. 3) and pour 3 decanters of cold water through the top opening at 3 minute intervals. After the third decanter is poured, water will flow through spray head
and funnel and fill decanter beneath.
4. Plug line cord into receptacle and tum on power switch. The power light will light, indicating power is applied to the tank heater, Wait approximately 15 minutes for the water
to reach brewing temperature, at which point the green light will light. You are now ready to brew coffee.
**BREWING INSTRUCTIONS**
AUTOMATIC MODELS BT2A, BT3A
1. Make sure power switch and green ready light are on. (Wait for green ready light to come on if necessary).
2. Place paper filter in brew funnel. Open pack of fine grind coffee (as recommended by your coffee supplier) and spread evenly on filter paper.
3. Insert Brew funnel back into machine and place empty decanter under funnel.
4. Tum on warmer switch and press brew switch. Coffee will be ready in 3% minutes.
5. Adjust timer (if necessary to fill decanter to just below band on handle)refer to instructions for timer adjustment).
6. Remove grounds and filter as soon as coffee has dripped through. Never pour coffee back through spent grounds.
POUR-OVER MODELS (BT2, BT3)
1. Follow steps 1, 2 and 3 above.
2. Fill decanter with cold water to just below band on handle, lift cover (69, Fig.3), and pour water through top of screened opening. Place empty decanter under funnel.
3. Tum on left warmer switch above decanter. Coffee will be ready in 3% minutes.
4. Remove grounds and filter as soon as coffee has dripped through. Never pour coffee back through spent grounds.
BACK-UP SYSTEM (FOR AUTOMATIC BREWERS)
In case of solenoid or timer malfunction or water supply problems (clogged strainer), automatic models may be usedf as pourover units simply by lifting cover and pouring
decanter through screened top opening.
**CLEANING INSTRUCTIONS**
1. Wash brew funnel and decanter by hand as needed. Do not use dishwasher, which may cause decanter breakage.
2. For cleaning all metal surfaces, use any reputable stainless steel cleaning compound.
Sprayhead should be checked and cleaned regularly. (Al least once a week.) Sprayhead holes must be kept open.
To prevent “LIMING" problems in the water tube and air tube, remove sprayhead and insert spring probe all the way into the tank through both tubes. When inserted into tank
properly, no more than two inches of the spring should be visible. Push back and forth five or six times. This will keep tubes open and clear of lime. In hard water areas, this
should be done every day; this takes less than a minute.
FOR AUTHORIZED SERVICE PERSONNEL ONLY
**SERVICE INSTRUCTIONS** and **TROUBLE SHOOTING GUIDE**
CAUTION: DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL REPAIRS
THERMOSTAT ADJUSTMENTS:
NOTE: The thermostat adjustment knob (fem 15) is located in back of top box. If water temperature is less than 197°F (92°C) slowly tum thermostat knob clockwise until ready light
goes out. When temperature of water approaches 197° to 203°F (92° to 95°C) slowly turn thermostat knob counter-clockwise until the green ready light comes on. If water temperature
cannot be increased when thermostat knob is tumed fully clockwise, then proceed as follows:
Remove Bracket and pull off knob. Place a small screwdriver into the center of thermostat shaft. While observing green ready light and temperature on thermometer. hold shaft and tum
small adjustment screw in center counter-clockwise until green ready light goes out. When temperature of water approaches 197°-203°F (92°-85°C), slowly tur screw clockwise until
ready light comes on. Tuming screw clockwise lowers temperature; counter-clockwise raises it. After adjusting center screw, place nail polish or glyplol on screw to set in
i
NOTE: As a final check, measure water temperature at Spray Head (25, Fig 3). Temperature should be 197° to 203°F (92° to 95°C).
TIMER ADJUSTMENTS (Automatic Models BT2A, BT3A)
NOTE: Timer adjustment knob is located in back of top box. To increase volume of water, tum knob of timer clockwise. To decrease, tum knob counter-clockwise. Turn knob by small
increments.
NOTE: Timer must go through a complete cycle before another adjustment can be made. Timer cannot be adjusted once it has been initiated.
PROBLEMS WITH WARMER ELEMENTS & SWITCHES:
If warmer plate fails to heat, first check power source and then check if light on warmer switch (21 Fig 3) is lit when in the “1" position. If warmer swilch is lit, replace warmer plate by
unplugging brewer, removing the two hold down screws on plate and withdrawing warmer plate from brewer. Replace the new warmer plate. If warmer switch does not light, replace it. To
remove switch press each tab behind front plate of brewer down with screwdriver in tum. As each tab is pressed, pop that corner of warmer switch out of the front of brewer. New switch
snaps in from the front.
IF WATER FAILS TO HEAT:
1. Red power light (20 Fig 3) and warmer switches do not come on, check power source. Replace fuse or reset circuit breaker if necessary. If power is good, check rear power switch for
continuity and replace if switch stays open.
2. If water still fails to heat, disconnect line cord and check out tank heater (31 Fig 3), thermostat (14 Fig 3) and high temperature safety shutoff (54 Fig 3). Replace needed
parts. :
MAINTENANCE ON AUTOMATIC MODELS BT2A, BT3A
IF NO WATER COMES FROM SPRAY HEAD AND POWER TO BREWER IS PRESENT CHECK:
1. Water Supply Line 2. Strainer/Filter
3. Solenoid 4. Timer
TESTING SOLENOID AND TIMER
Make sure brewer s property primed. Tum on power swich and then warmer switch above funnel. Press brew switch and hold for one minute. f solenoid buzzes and water flows through spray head when brew
Switch s pressed and held, but siops when switch is released, timer is defective. Replace i. If no water flows from spray head, and solenoid is inactive, frst check brew switch and wiring to solenoid and replace as
necessary. if brew switch and wiring are okay, solenoid is at fault
REPLACING SOLENOID, TIMER, HI-LIMIT, THERMOSTAT AND TANK HEATER (See III. 3)
Unplug power cord, shut off water supply (for automatic brewers) and remove top cover.
Solenoid (Нет 1)- Remove electrical connections, (2) screws, water inlet fitting and silicone tubing. Replace with new solenoid.
Timer (item 13) - Loosen and remove (2) screws in back of top box. Lift out imer and disconnect the color coded wires one by one and connect same lo replacement timer. Place
pointer of knob to center and dial range.
Hi-Limit Switch (Item 54)- Disconnect the (2) push-on leads, loosen large nut on heating element terminal and pull out hi-limit bracket (hem 53). Replace swilch (em 54),
Thermostat (Item 16)- Remove water tank insert (item 40), thermstat bulb clip (em 48), hex nut (Hem 42) from capillary tank fitting, thermostat knob guard (Hem 14), and (2) screws
securing thermostat fo housing. Disconnect the push-on leads and remove thermostat. Replace with new one in reverse order. When installing new control, do nol
overtighten small packing nut on compression fitting.
Tank Heater (ltem 32) Remove tank insert (tem 40), bulb clip (em 48), (2) hex nuts and washers. Disconnect push-on leads. Replace in reverse order.
= a
Line Cord Switch LOG9A
c99Na
OFF
EN goon |
| pe Top Wormer 8 Switch RETA
I for BT 3 only
| | e
| ь — a]
LISSA | : E Di
| | E G231A
| ' , Werner I120V 400 W
| Yee | Г o io
| I -
LA -——— T == Reody ligh mi ia
L289A | DUDE |
o E a BROWN —--—— >» —
Г Switeh for right RED:
Su, fom bent =~ ma ; bottom Wormar
"om Mar =
LISSA 63 lo Не
E e
= — N207A
WIRING DIAGRAM FOR BT3
Fig.1
REPLACEMENT PARTS LIST FOR BT SERIES BREWERS
Мет # Description Part 4 Where Used tem # Description Part # Where Used
1 Solenoid Valve L298A All Automat
: нд" 40 Water Tank Insert Q141Q BT2A BT3A
2 pais Screen #10 x % “A PO50A All Automat 40 Water Tank Insert Q1340 BT2, BT3
rg 41 Tank Cover Gasket M215A
3 Solenoid Fitting Gasket MIB2R Al Autgmt 42 Yax 18% Hex nut- BT K207A
4 Solenoid Fitting K178A All Automat 47 Water Inlet Tub H168V
5 Solenoid Tinnerman P228A All Automat P143A All Automatic
8 Switch Guard US65V * — TRATO 200
9 Heater on/off switch LO69A т tal U623A
10 Filling Hose M222J — All Automat = sous
11 Hose Clamp P216A All Automat
12 #6-32 x Ya Screw P183A
13 Solid State Timer L265A All Automat 49 Water Tank Q133A BT2, BT3
15 Thermostat Knob MOOBA 49 Water Tank Q140A BT2A 3A
16 Thermostat LOO2A 50 Stainless Steel Washer P175A
17 #8-32 x % Screw PO12A 51 Spray Head Gasket M121A
19 4%" Grommet M218A 52 #6-32 Tinnerman POBBA
20 Red Power Light C260A 53 Hi-Limit Bracket U556E
21 Warmer Switch L155A 54 HiLimit L267A
22 Brew Switch L291A All Automat 61 Heyco Bushing BO12A
Brew Ready Light L289A BT2,3 62 Line Cord C9980
24 Spray Head Adapter E007 63 Warmer Element Assembly GO95A
25 Spray Head EO26A 64 #6-32 x % Screw P139A
funnel 66 Warmer Spacer P205A BT 3,3A
26 Funnel Runner (Left) w/VOO4A USB4A 87 %" Grommet MO90A
funnel 68 Pour-Over Dish US87Q
27 Funnel Runner (Right) w/VOO4A USB5A 69 Cover Assembly Us38Q
27 Funnel Runner (Right) w/VOOOA US62A 71 Chain P291A
funnel
28 Bottom Cover R393A
20 Rubber Foot M134A
30 Mounting Screw #6-32 x % P271A "NOT SHOWN
31 318 x Ya Brass FTG KO38A MO Cecilware Funnel (Standard) VOOOA
32 Tank Heater 1400W @ 120V G231A Biack
33 Overlow Tube H164A Brewmatic Funnel (Small) VOO4A
34 Hose Clamp P223A Filter Paper for A-12
= Spray Tub - 2PC es es Filter Paper for A-10
op Cover . ing (Small V161A
us R402V BTS 3A Clean Out Spring ( )
К a
| AA E
CA ws
SR) |
k |
ИГ.
DO
ALA
e ds e Li
DOE
BT 3 (shown)
;
|
VON
Fig. 3
"—-=c©@ sno
(J114) ELECTRICAL SCHEMATIC FOR BT BREWERS
SYM. | Part Description P/N
DS1 | Power Light C260A
K1 Solenoid L298A
K2 | Timer Relay L265A
R1 Tank Heater G231A
W1 | Left Warmer GO97A
W2 | Right Warmer GO97A
W3 | Top Warmer BT3, BT3A GO97A
51 Main Power Switch LO69A
53 Brew Cycle Control L155A
& Left Warmer Swilch
S4 | Right Warmer Swilch L155A
55 | Brew Switch BT2A, BT3A | L291A
S6 | Hi-Limit Switch L267A
S7 | Thermostat L266A
100-203 Degree F
BL Black Wire
WH | White Wire
BR Brown Wire
Red | Red Wire |
Blue | Blue Wire |
Omit the following parts on BT2 and BT3 Units:
K1. K2. 55 (Pins *1 and #2)
ELECTRICAL SCHEMATIC FOR BT BREWERS
— THERMOSTAT
TIMER WITHOUT WATER TAP CONNECT
2804 wing (1) TO TIER (TERMAL LY) —
==
STL-24 00 | == L
a BTL-2AWT OD E (О |
"
A =
== || e ¡es
1 |
TERMINAL !
du ñ шей
8 a 231 A 1400 W @ 20V
| ;
1
|
'
| "
|
POWER "
SWITCH | Z
L 181 A | в
| ” LE e ——]
a > Hi o. ura
— ll 100 W@ 120 v 100 W(D IZO Y
WARMER
A |
— WHITE ME
— BLACK WIRE
— BW WIRE
FIG. 1 16 KW @ 120V 50/60 HZ N 207 A
WT
НЕО м
As a 6 Zo #5 5 Oz =
ss = 5 æs de EF o Е = Ds E =
BREW BREW READY
SWITCH LIGHT
LIBEA LISTA
WARMER
CORT A
100 ww (D IZO Y
SWITCH
LISCA
NEO WIRE
LINE CORD — WHITE WIRE
— ONEEN WINE
— BLACK WIRE
213, ST 3A, BT SANT —— mue une
@ 50/60 HZ cui A cite
1.7 KW 120 \
FIG. © - 11/15/65 N 208 A