3. Programming:
3.1: Press the PRG-button to start
programming
3.2: Press the DAY-button several
times to select which day(s) the
program is to be executed.
1. Initial operation:
1.1 Turn on the heater and wait for
approx. 5 min for the timer-unit
to charge. If the battery back-up
is empty, the display may need a
charging-time of at least 30 min.
before normal operation.
1.2 Press the RST-button to reset
the unit.
3.3: Press the HR/MIN-buttons to set
the ON-time for the program.
3.4: Press the PRG-button to
acknowledge the ON-time
setting.
2. Time-setting:
2.1 Day:
Press the TIME- and DAY-
buttons simultaneously. The day-
value increases by one.
3.5:Repeat step 3.2-3.3 for OFF-
time setting.
2.2 Hour:
Press the TIME- and HR-buttons
simultaneously. The hour-value
increases by one.
Note:
For the summer-/winter-time
function to work properly; adjust
the hour according to winter-time
3.6: Press the PRG-button to
acknowledge the OFF-time
setting.
3.7:Repeat step 3.2-3.6 for Program
2-6
2.3 Minute:
Press the TIME- and MIN-
buttons simultaneously. The min-
value increases by one
3.8:Return to normal operation by
pressing the TIME-button
HR
= O O
Note: For fast increasement of time-values, press the DAY-,HR- and
MIN-buttons for more than 1 sec.
Downloaded from www.Manualslib.com manuals search engine
4. Normal operation:
Press the \ -button to switch between the 4 different operation
modes.
4.1: Auto ON/Auto OFF modes. (
In these modes the heater's
element responds to the ON-/
OFF-times in the different
programs.
4.2: ON-/OFF-modes.
In these modes the heater's
element is constant ON or OFF,
and is not under control by any
programs.
5. Summer-/winter-time function:
Make sure that the hour-value is set according to winter-time for
this function to work properly.
Press the TIME- and \-buttons
simultaneously to activate the
function.
Repeat the operation to deactivate
the function.
6. Random function:
This function is to be used in case of several heaters running on
the same supply-course to prevent overload situations at
programs with coincident ON-time settings.
Press the TIME- and PRG-buttons
simultaneously to activate the
function.
Repeat the operation to deactivate as
the function. AO OO
Note: For this function to work properly, the interval between
On-/Off-times should be minimum 33 minutes.
7. Skip (RCL) function:
This function provides the possibility of overriding the programs in
such a way that their ON- or OFF-time settings will not be
executed.
7.1: Press the PRG-button.
7.2: Press the PRG-button several
times to select the desirable
program (ON- or OFF-time).
7.3:Press the RCL-button to override |
the desirable setting. If the OFF-
time is selected, the ON-status
Will retain until the next
program's OFF-time is reached.
7.4: Press the TIME-button to return
to Normal operation mode.
Repeat step 7.1-7.4 to deactivate the function.
8. Unit failure:
Contact your supplier for replacement of the unit if the display
remains blank after charging (ca. 5 min), or fails to operate in any
other ways.