Cen-Tech 61593 11 Function Digital Multimeter Owner's Manual


Add to my manuals
12 Pages

advertisement

Cen-Tech 61593 11 Function Digital Multimeter Owner's Manual | Manualzz

Owner’s Manual & Safety Instructions

Save This Manual

Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number).

Keep this manual and the receipt in a safe and dry place for future reference.

REV 14f

Visit our website at: http://www.harborfreight.com

Email our technical support at: [email protected]

When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible.

Copyright

©

2004 by Harbor Freight Tools

®

. All rights reserved.

No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools.

Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein.

Tools required for assembly and service may not be included.

Read this material before using this product.

Failure to do so can result in serious injury.

SAVE THIS MANUAL.

Table of contents

Safety ..........................................2

Specifications ..............................6

Setup ...........................................5

Operation .....................................7

Maintenance ...............................11

Warranty .....................................12

WARNING SyMBOLS AND DEFINITIONS

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

Addresses practices not related to personal injury.

IMpORTANT SAFETy INFORMATION

Safety Warnings and precaustions

Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.

Save all warnings and instructions for future reference.

1. Electrical shock can cause death or injury! NEVER TOUCH exposed conductors of electricity.

c. Replace damaged test lead immediately, before use.

3. Do not use the multimeter if:

2. Inspect the Multimeter before use. In addition to a general inspection, look specifically for: a. The test lead is damaged in any way.

b. The battery is low.

a. Pay special attention to the insulation protecting the connectors.

c. Near any explosive gasses or fumes.

b. Check the leads for exposed metal, damaged insulation, and continuity.

Page 2

For technical questions, please call 1-888-866-5797.

Item 37772 61593

d. Any abnormal operation is detected.

(If in doubt about the condition of the meter, have it serviced.) e. The battery cover is open.

4. This meter should be powered only by a single, correctly installed 9V battery.

5. Use caution when working near voltages above 30 VAC rms, 42 VAC peak, or 60 VDC. Voltages this high present a risk of electric shock.

6. Disconnect the circuit’s power before connecting the meter in series, when measuring current.

7. Connect the common (COM) test lead first and disconnect it last.

8. Hold the probes with fingers behind guards.

9. Avoid electrical shock. Use extreme caution when working near uninsulated conductors or bus bars. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and cabinet enclosures when testing voltages.

10. Observe work area conditions. Do not test voltages in damp or wet locations. Don’t expose to rain.

Keep work area clean and well lit.

11. Keep children away. Children must never be allowed in the work area.

12. Stay alert. Watch what you are doing, use common sense. Do not operate any meter when you are tired.

13. Do not operate meter if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgment or reflexes are impaired while taking drugs. If there is any doubt, do not operate the meter.

14. WARNING: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health &

Safety Code § 25249.5,

et seq.

)

15. WARNING: The cord of this product contains lead, a chemical known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. (California Health &

Safety Code § 25249.5,

et seq.

)

16. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.

17. Do not test voltage on circuits higher than 750 volts AC or 1000 volts DC.

This type of testing should only be done by a qualified electrician.

18. Do not test current on circuits higher than 20 mA.

19. Store idle equipment. When not in use, meters must be stored in a dry location to decrease exposure to moisture. Lock up meters and keep out of reach of children.

20. Dress properly. Protective, electrically nonconductive clothes and nonskid footwear are recommended when working.

21. Wear ANSI-approved safety goggles during use.

22. Only use accessories intended for use with this meter.

Item 37772 61593

For technical questions, please call 1-888-866-5797.

Page 3

23. The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.

24. Avoid damaging meter. Use only as specified in this manual.

25. Prior to testing, resistance, diodes, or continuity; disconnect all power to the circuit and discharge all high-voltage capacitors.

26. Performance of this meter may vary depending on battery condition.

27. Use the proper settings, terminals, techniques, and range for the tests performed. Start with the range stated in the instructions.

28. Do not apply voltage to the Test

Leads when the Multimeter is in the Ohms testing setting. Damage can occur to the multimeter.

29. Do not switch between testing modes with the multimeter connected to a circuit.

30. Do not use the meter at a setting marked as blank on the scale.

31. Prior to testing capacitors, resistance, diodes, or continuity; disconnect all power to the circuit and discharge all high-voltage capacitors.

32. Have the Multimeter calibrated by a qualified technician every year. A multimeter that is not calibrated yearly may not yield accurate results.

SAVE THESE INSTRUcTIONS.

Page 4

For technical questions, please call 1-888-866-5797.

Item 37772 61593

Setup - Before Use:

Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Functions

Diode position continuity position power

Resistance

Section

Range

Selector

Switch

Hold

Frequency

Section

Dc Volt

Section capacitance

Section

Dc current

Section capacitance

Testing

Socket (cx)

Ac Volt

Section

Temperature

Section

Temperature

Measuring

Socket

Transistor

(hFE) Section

Transistor

Testing Socket

20A

Jack mA

Jack cOM

Jack

Ac current

Section

V/Ω/Hz

Jack

Item 37772 61593

For technical questions, please call 1-888-866-5797.

Page 5

Specifications

Max. Voltage

DC Voltage

DC Voltage Accuracy

AC Voltage

AC Voltage Accuracy

DC Current

DC Current Accuracy

AC Current

AC Current Accuracy

Resistance

Resistance Accuracy

Capacitance

Capacitance Accuracy

Frequency

Frequency Accuracy

Temperature

Temperature Accuracy

Sampling Rate

Overload Protection

Operating Temperature

Display

Battery

1000Vdc/700rms ac (sine)

Ranges: 200mV/2/20/200/1000V

(@200mV-200V) 0.5% of rdg ±1D;

(@1000V) 0.8% of rdg ±2D

Ranges: 200mV/2/20/200/700V

Frequency Range: 40-400Hz

(@200mV) 1.2% of rdg ±3D;

(@2-200V) 0.8% of rdg ±3D;

(@700V) 1.2% of rdg ±3D

Ranges:200μA/2mA/20mA/2A/10A

(@ 200μA-20mA) 0.8% of rdg ±1D

(@200mA-2A) 1.5% of rdg ±1D

(@10A) 2% of rdg ±5D

Ranges: 200μA/2mA/20mA/2A/10A

Frequency Range: 40-400Hz

(@ 200μA&200mA) 1.8% of rdg ±3D

(@ 2mA-20mA) 1.0% of rdg ±3D

(@ 10A) 3.0% of rdg ±7D

Ranges: 200Ω/2KΩ/20KΩ/200KΩ/2MΩ/20MΩ

(@200Ω) 0.8% of rdg ±3D;

(@2K-2MΩ) 0.8% of rdg ±1D;

(@20MΩ) 1.0% of rdg ±2D;

Ranges: 2nF/20nF/200nF/2μF/20μF

(@2nf-20μF) 4.0% of rdg ±3D

Range: 20KHz

(@20KHz) 1.5% of rdg ±5D

Range: -20° to 1000°C

(@-20° to 0°C) 5.0% of rdg ±4D

(@ 0° to 400°C) 1.0% of rdg ±3D

(@ 400° to 1000°C) 2.0% of rdg

2-3 times/second

Fast-Acting 200mA/250V Fuse

Range: 32° - 104° F

LCD

One 9 V (included)

Page 6

For technical questions, please call 1-888-866-5797.

Item 37772 61593

Operating Instructions

Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Tool Set Up

1. There are different functions and 30 ranges provided. A rotary switch is used to select functions as well as ranges.

2. A Power Button is used to turn the meter on or off.

3. A push - push switch (push ON, push OFF) is used to hold data.

This switch can be used with all available settings, including DCV,

ACV, DCA, ACA, Hz, and C.

4. As a general rule, the LCD display box is locked. To adjust the angle of the display, pull on the top of the meter and rotate it.

Function

200mV & 200mV~

V & V~

Red Lead connection

V/

Ω or

V/

Ω/Hz

V/

Ω or

V/

Ω/Hz

(

Hz

Ω

μ

,

A) mA & (

2A & 2A~

μ

A) mA~

V/

V/

V/

Ω or

V/

Ω/Hz

Ω or

V/

Ω/Hz

Ω or

V/

Ω/Hz mA

A

20A & 20A~ 20A

5. This meter has four input jacks that are protected against overload to the limits shown. Depending on the intended function, connect either the black or red test lead to the COM jack.

6. WARNING! Before attempting to insert a transistor’s capacitor thermocouple for testing, disconnect the Test Leads from all measurement circuits.

7. WARNING! Before taking voltage measurements with Test Leads, remove the thermocouple. Do not connect Test Leads to the hFE or capacitor socket.

Input Limits

250Vdc or rms ac

1000Vdc, 700Vac (sine)

250Vdc or rms ac

250Vdc or rms ac

250Vdc or rms ac

200mAdc or rms ac

2Adc or rms ac

10A dc or rms ac continuous

20A for 15 seconds maximum

Additional Multimeter precautions

1. Do not test voltage on AC circuits higher than 700 volts.

2. Do not test voltage on DC circuits higher than 1000 volts.

3. Do not test current on circuits higher than 20 amps.

Item 37772 61593

4. Be careful not to apply voltage to the

Test Leads when they are connected to the COM and VΩmA Jacks or when the Multimeter is in an Ohms testing setting. Damage can occur to the multimeter and the fuse may blow.

5. Do not switch between testing modes with the multimeter connected to a circuit.

For technical questions, please call 1-888-866-5797.

Page 7

General Operating Instructions

Ac Voltage Measurements

Measure AC conductors carrying up to 700 VAC, 45-450 Hz.

1. Turn the Range Selector Switch to

700 ACV setting. Start with the highest range if the voltage is unknown.

2. Plug the red lead into the V/Ω/Hz Jack.

Plug the black lead into the COM

Jack. Switch the Multimeter ON.

3. Carefully touch the exposed conductors with the tips of the probes to measure the voltage (not amperes).

4. Read measurement. If the voltage is less than 200 volts, set the Range

Selector Switch to the lower range.

5. When testing is complete, remove

Test Leads and store with multimeter.

Dc Voltage Measurements

Measure DC conductors carrying up to 1000 VDC.

1. Turn the Range Selector Switch to 1000 DCV setting.

Ac current Measurements

Measure AC conductors carrying up to 20 amperes.

1. Turn the Range Selector Switch to the

20A~ position. Start with the highest range if the amperage is unknown.

2. Plug the red lead into the 20A

Jack. (For current under 20A, plug the red lead into the mA Jack.)

Plug the black lead into the COM

Jack. Switch the Multimeter ON.

2. Follow the directions above under

“AC Voltage Measurements”, only use the DC settings instead.

3. Carefully touch the exposed conductors with the tips of the probes to measure the amperage.

Note:

Amperage is always tested in series with the circuit under test.

4. Read measurement. If the reading is less than 0.2 amps, switch the red lead to the VΩmA Jack and set the Range

Selector Switch to the 200 mA setting.

5. When testing is complete, remove

Test Leads and store with multimeter.

Dc current Measurements

Measure DC conductors carrying up to 20 amperes.

1. Turn the Range Selector Switch to the

20A position. Start with the highest range if the amperage is unknown.

2. Follow the directions above under

“AC Current Measurements”, only use the DC settings instead.

Page 8

For technical questions, please call 1-888-866-5797.

Item 37772 61593

Resistance Measurements

Measure circuit resistance up to 20M Ohms.

WARNING!

Do not measure resistance on circuit with voltage running through it.

Notice:

When measuring Ohms, start with the lowest range if the resistance is unknown.

1. Turn the Range Selector Switch to the 200Ω position.

2. Plug the red Test Lead into the V/Ω/

Hz Jack. Plug the black Test Lead into the COM Jack. Switch the Multimeter

ON. Short the Test Leads together.

The meter should read “0” Ohms.

3. Touch the exposed conductors with the tips of the Test Leads.

4. Read measurement. If the reading is

“1”, set the Range Selector Switch to the next higher Ohm (Ω) position.

5. When measuring resistance above 1

MΩ, the meter may take a few seconds to give a stable reading. This is normal for high resistance measurements.

6. At the 20MΩ range, the display reading will be around 0.1 counts over the actual measurement. These counts should be subtracted from the resulting reading. For example, when measuring

10 MΩ resistance, the display will read

10.1, but the correct measurement should be 10.1-0.1=10.0MΩ

7. Remove and store Test Leads.

capacitance Measurements

Measure capacitance up to 20μF.

1. Turn the Range Selector Switch to the

20μF position. Start with the highest range if the capacitance is unknown.

WARNING!

Fully discharge capacitor before measuring.

2. Plug capacitor into the capacitance testing socket (Cx).

Switch the Multimeter ON.

3. Read measurement. If the reading is less than 20μF, set the Range

Selector Switch to a lower range.

WARNING!

Avoid electric shock.

Remove capacitor before switching between testing modes.

Frequency Measurements

Measure frequency up to 20kHz.

1. Turn the Range Selector Switch to the 20kHz position.

2. Plug the red Test Lead into the V/Ω/Hz

Jack. Plug the black Test Lead into the

COM Jack. Switch the Multimeter ON.

Note:

Reading is possible at input voltages above 10Vrms, but the accuracy is not guaranteed.

Note:

In noisy enviroments, use a shield cable to measure smaller signals.

3. Remove and store Test Leads.

Item 37772 61593

For technical questions, please call 1-888-866-5797.

Page 9

Transistor (hFE) Measurements

Test transistors to ensure proper function.

1. Turn the Range Selector Switch to the hFE position. Switch the Multimeter ON.

2. Insert transistor pins into the appropriate holes of the hFE testing socket (NPN or PNP) according to the EBC (Emitter,

Base, Collector) sequence.

Temperature Measurement

1. Turn the Range Selector Switch to the TEMP position. Switch the

Multimeter ON. Display will show the current ambient temperature.

2. Plug a “K”-type thermocouple into the temperature measuring socket.

3. The meter will show the approximate hFE value at the test condition of base current 10μA and Vce 3.2V.

4. Remove and store Transistor.

Diode Measurement

Test the voltage drop in diodes.

1. Turn the Range Selector Switch to the Diode ( ) position.

2. Plug the red Test Lead into the V/Ω/Hz

Jack. Plug the black Test Lead into the

COM Jack. Switch the Multimeter ON.

3. Connect red probe to the anode of the diode and the black to the cathode.

4. The approximate forward voltage drop of the diode will be displayed in mV. If the connection is reversed, only “1” will be shown.

5. Remove and store Test Leads.

continuity Measurement

Test continuity between two points of a circuit.

1. Turn the Range Selector Switch to the position. Switch the Multimeter ON.

2. Connect Test Leads to two points of the circuit. If continuity exists

(i.e., resistance is less than

50Ω), a buzzer will sound.

3. Remove and store Test Leads.

3. Contact object to be measured with the thermocouple probe.

Read measurement.

WARNING!

Avoid electric shock.

Remove thermocouple before switching between testing modes.

Page 10

For technical questions, please call 1-888-866-5797.

Item 37772 61593

Maintenance and Servicing

procedures not specifically explained in this manual must be performed only by a qualified technician.

cleaning, Maintenance, and Lubrication

1. Wipe unit with a dry, lint-free cloth.

Do not use solvents or abrasives.

2. Remove battery if not in use for long periods.

3. Store unit in a dry location.

4. Other than the battery and fuse, there are no replaceable parts on this unit. Repairs should be done by a qualified technician.

Battery/Fuse Replacement

If the sign “ ” appears on the LCD display, the battery should be replaced.

1. Remove the Test Leads from the multimeter.

2. Turn the unit over.

3. Remove screws.

4. Remove back cover carefully.

There may be wires attached.

5. Pull battery/fuse out of unit and replace with the same. (9V battery or F 2A/250V (quick acting) fuse)

6. Replace cover and retighten screws.

Record Serial Number Here:

Note:

If product has no serial number, record month and year of purchase instead.

Item 37772 61593

For technical questions, please call 1-888-866-5797.

Page 11

Limited 90 Day Warranty

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.

This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR

IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.

To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

3491 Mission Oaks Blvd. • pO Box 6009 • camarillo, cA 93011 • 1-888-866-5797

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Measures voltage, current, and resistance
  • Large, easy-to-read LCD display
  • Rugged construction for use in harsh environments
  • Auto-ranging for quick and easy measurements
  • Data hold function for freezing measurements on the display
  • Continuity beeper for testing circuits
  • Diode test function for testing diodes
  • Transistor test function for testing transistors
  • Capacitance measurement function for testing capacitors
  • Frequency measurement function for testing frequencies

Questions & Answers

2024-05-20

P P A

How can I check if my leads are bad?
To determine if your leads are bad, it's recommended to track and analyze their interactions, behaviors, and characteristics in relation to your business offerings. Some common indicators of bad leads include consistently low engagement, incorrect or incomplete information, mismatched needs, lack of budget, lack of decision-making power, and excessive objections or complaints.

Related manuals

Frequently Answers and Questions

What is the maximum voltage that the CEN-TECH 61593 can measure?
The CEN-TECH 61593 can measure up to 750 volts AC or 1000 volts DC.
What is the maximum current that the CEN-TECH 61593 can measure?
The CEN-TECH 61593 can measure up to 20 mA.
What is the maximum resistance that the CEN-TECH 61593 can measure?
The CEN-TECH 61593 can measure up to 20 MΩ.
How do I use the continuity beeper on the CEN-TECH 61593?
To use the continuity beeper on the CEN-TECH 61593, first set the meter to the continuity setting. Then, touch the test leads to the two points that you want to test. If there is continuity between the two points, the beeper will sound.
How do I use the diode test function on the CEN-TECH 61593?
To use the diode test function on the CEN-TECH 61593, first set the meter to the diode test setting. Then, touch the test leads to the two terminals of the diode. If the diode is good, the meter will display the forward voltage drop across the diode.
How do I use the transistor test function on the CEN-TECH 61593?
To use the transistor test function on the CEN-TECH 61593, first set the meter to the transistor test setting. Then, touch the test leads to the three terminals of the transistor. The meter will display the type of transistor and its hFE.
How do I use the capacitance measurement function on the CEN-TECH 61593?
To use the capacitance measurement function on the CEN-TECH 61593, first set the meter to the capacitance measurement setting. Then, touch the test leads to the two terminals of the capacitor. The meter will display the capacitance of the capacitor.