Promax PROLITE-60 User manual


Add to My manuals
142 Pages

advertisement

Promax PROLITE-60 User manual | Manualzz

PROLITE-60

ANALIZADOR DE ESPECTROS ÓPTICOS

FIELD OPTICAL SPECTRUM ANALYSER

ANALYSEUR DES SPECTRES OPTIQUES

- 0 MI1503 -

NOTAS SOBRE SEGURIDAD

Antes de manipular el equipo leer el manual de instrucciones y muy especialmente el apartado PRESCRIPCIONES DE SEGURIDAD.

El símbolo

sobre el equipo significa "CONSULTAR EL MANUAL DE

INSTRUCCIONES". En este manual puede aparecer también como símbolo de advertencia o precaución.

Recuadros de ADVERTENCIAS Y PRECAUCIONES pueden aparecer a lo largo de este manual para evitar riesgos de accidentes a personas o daños al equipo u

otras propiedades.

SAFETY NOTES

Read the user’s manual before using the equipment, mainly " SAFETY RULES " paragraph.

The symbol

on the equipment means "SEE USER’S MANUAL". In this manual

may also appear as a Caution or Warning symbol.

Warning and Caution statements may appear in this manual to avoid injury

hazard or damage to this product or other property.

REMARQUES A PROPOS DE LA SÉCURITÉ

Avant de manipuler l'appareil, lire le manuel d'utilisation et plus particulièrement le paragraphe "PRESCRIPTIONS DE SÉCURITÉ".

Le symbole sur l'appareil signifie "CONSULTER LE MANUEL D'UTILISATION".

Dans ce manuel, il peut également apparaître comme symbole d'avertissement ou de précaution.

Des encadrés AVERTISSEMENTS ET PRECAUTIONS peuvent apparaître dans ce manuel pour éviter des risques d'accidents affectant des personnes ou des dommages

à l'appareil ou à d'autres biens.

SUMARIO

CONTENTS

SOMMAIRE

Manual español.............................................................

English manual.............................................................

Manuel français ..............................................................

MANUAL DE INSTRUCCIONES. PROLITE-60

Í N D I C E

1 GENERALIDADES .................................................................................................... 1

1.1

Descripción ......................................................................................................... 1

1.2

Especificaciones.................................................................................................. 2

2 PRESCRIPCIONES DE SEGURIDAD ...................................................................... 5

2.1

Generales ......................................................................................................... 5

2.2

Ejemplos Descriptivos de las Categorías de Sobretensión ................................ 7

2.3

Precauciones Específicas para la opción OP-A: Fuente de banda ancha.......... 7

3 INSTALACIÓN ......................................................................................................... 9

3.1

4

Alimentación........................................................................................................ 9

3.1.1

Carga de la batería ....................................................................................... 9

3.1.2

Recomendaciones en el uso de la batería.................................................. 10

3.2

Instalación y puesta en marcha......................................................................... 10

3.3

Salvapantallas ................................................................................................... 10

INSTRUCCIONES DE USO .................................................................................... 11

4.1

Descripción de los Mandos y Elementos .......................................................... 11

4.2

Instrucciones básicas de operación .................................................................. 13

4.2.1

Control del MARKER: ................................................................................. 13

4.2.2

Control del SPAN:....................................................................................... 14

4.2.3

Control de TRACE: ..................................................................................... 15

4.2.4

Control de AMPLITUDE:............................................................................. 17

5 Modo FUNCTIONS (CONFIGURATION MENU)..................................................... 19

5.1

Descripción ....................................................................................................... 19

5.2

Funciones de configuración del equipo............................................................. 20

5.2.1

Menú SETTINGS ........................................................................................ 20

5.2.2

Menú UPGRADE ........................................................................................ 22

5.2.3

Ventana ABOUT ......................................................................................... 23

5.3

Funciones de medida del equipo ...................................................................... 24

5.3.1

Función LED MEASURE ............................................................................ 24

5.3.2

Función DWDM MEASURE........................................................................ 26

5.3.3

Función DFB MEASURE (Distributed Feedback)....................................... 28

5.3.4

Función FP MEASURE (Fabry-Perot) ........................................................ 30

5.3.5

Función OA MEASURE (Optical Amplifiers)............................................... 31

6 Control REMOTO (WEB SERVER) ......................................................................... 35

6.1

Trazas (TRACES) ............................................................................................. 36

6.2

Imágenes (IMAGES) ......................................................................................... 36

6.3

Modo Remoto (REMOTE MODE) ..................................................................... 37

6.4

Actualizar (UPGRADE) ..................................................................................... 38

7 MANTENIMIENTO................................................................................................... 39

7.1

Métodos de mantenimiento ............................................................................... 39

7.1.1

Limpieza de la caja. .................................................................................... 39

7.2

Componentes no sustituibles por el usuario ..................................................... 39

7.2.1

Fusibles no sustituibles por el usuario ........................................................ 39

APÉNDICE A: Guía Rápida de Utilización..................................................................... 41

MANUAL DE INSTRUCCIONES. PROLITE-60

MANUAL DE INSTRUCCIONES. PROLITE-60

ANALIZADOR DE ESPECTROS ÓPTICOS

PROLITE-60

1 GENERALIDADES

1.1 Descripción

El PROLITE-60 es un analizador de espectros ópticos, portátil que funciona con baterías. Resulta adecuado para múltiples aplicaciones, entre las que se incluye la comprobación de sistemas de telecomunicación WDM (Wavelength Division

Multiplexing) / CWDM (Coarse Wavelength Division Multiplexing), además mediante varias opciones y accesorios disponibles también puede ser utilizado en aplicaciones de reflectometría, análisis de materiales, sensores de fibra óptica, comprobación de dispositivos fotónicos tales como filtros, atenuadores, acopladores, aisladores y otros componentes ópticos.

El instrumento incorpora funciones especificas que le permiten caracterizar la respuesta de diferentes sistemas de transmisión óptica, como por ejemplo las medidas de LEDs, DWDM, DFB, FP, OA, etc.,. Todas estas medidas son configurables a través de los parámetros accesibles para el usuario mediante menús gráficos sobre la pantalla de uso intuitivo.

En el modo de análisis del espectro óptico dispone de dos cursores desplazables que actúan como marcadores a lo largo del margen de exploración de las longitudes de onda.

El SPAN es variable de 10 nm a 400 nm para facilitar la visualización del espectro en la escala horizontal, también sobre la escala vertical se pueden establecer divisiones de 10 dB o 2 dB para obtener una mayor resolución en las medidas.

Incorpora diez posiciones de memoria para almacenar las trazas registradas previamente y trabajar con ellas posteriormente. Las medidas adquiridas pueden revisarse, transferirse a un PC o imprimirse en cualquier momento. También permite el acceso remoto a los datos registrados a través de una red TCP/IP (web server).

El PROLITE-60 da respuesta a las necesidades de medidas selectivas en longitud de onda, de los operadores de telecomunicaciones que transmiten simultáneamente múltiples longitudes de onda a través de una misma fibra óptica, con el fin de rentabilizar las redes existentes.

En el diseño del PROLITE-60 se ha dedicado especial atención en realizar un equipo práctico y preciso, pero a la vez fácil de usar. Un completo teclado alfanumérico con selector rotativo permite el acceso directo a las diferentes funciones de medida.

La implementación de todas estas funciones en un instrumento de reducidas dimensiones y peso, diseño ergonómico y robusto, convierten al PROLITE-60 en una herramienta muy útil para el trabajo de campo.

MANUAL DE INSTRUCCIONES. PROLITE-60

1.2 Especificaciones

LONGITUD DE ONDA

Margen de longitudes de onda

De 1250 a 1650 nm

Resolución óptica

Precisión

0,15 nm

± 0,5 nm

POTENCIA

1

Margen dinámico

De -60 dBm a 10 dBm

Precisión

± 0,50 dB

Estabilidad

Relación señal ruido óptica (OSNR)

Selectivo a 1550 nm

a 25 GHz (± 0,2 nm)

a 50 GHz (± 0,4 nm)

a 100 GHz (± 0,8 nm)

POLARIZACIÓN

18 dB (min.)

25 dB (min.)

30 dB (min.)

CICLO DE BARRIDO

CONECTORES

Óptico estándar

FC/PC

PRESENTACIÓN MONITOR

Monitor TFT color de 6,4 “

INTERFAZ DE COMUNICACIONES

Puerto serie RS232

ALIMENTACIÓN

Tensión de alimentación

Indicador batería baja

Autonomía

Apagado automático

Carga de batería

Consumo equipo

100-240 V AC

Indicación gráfica en el display:

Aproximadamente 3 horas.

Desconexión con temporización configurable (1 a 240 min.)

Por cargador rápido interno.

36 W.

1

Valores válidos para fibras ópticas (9/125 µm) y conector FC/PC.

Página 2 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

CONDICIONES AMBIENTALES DE OPERACIÓN

El equipo puede funcionar en las siguientes condiciones ambientales de operación, también en estas condiciones se mantendrán las especificaciones:

Altitud Hasta 2.000 m.

Margen de temperaturas

°C a 40 °C.

Humedad relativa máxima

CARACTERÍSTICAS MECÁNICAS

80 % (Hasta 31 °C), decreciendo linealmente hasta el 50% a 40 °C.

Dimensiones

Peso

ACCESORIOS INCLUIDOS

CA-005 Cable de red.

0 FD0453

OPCIONES

294 A. x 126 Al. x 274 Pr.

5,7 kg.

Funda de transporte.

A Fuente de banda ancha.

Fuente de luz SLED de 1566 nm (Consultar posibles alternativas).

Potencia

BW

3dB

- 8 dBm

73

72

71

70

Conector óptico FC - PC

Conector óptico SC - PC

Conector óptico FC - E2000

Conector óptico FC — ST

(Consultar disponibilidad en conectores APC)

MANUAL DE INSTRUCCIONES. PROLITE-60

Página 4 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

*

*

2 PRESCRIPCIONES DE SEGURIDAD

2.1 Generales

*

Este es un equipo de clase I por razones de seguridad debe conectarse a líneas

de suministro con la correspondiente toma de tierra.

*

Utilizar el equipo en instalaciones con Categoría de Sobretensión II y ambientes con Grado de Polución 2.

*

Al emplear cualquiera de los siguientes accesorios debe hacerse sólo con los tipos especificados a fin de preservar la seguridad:

Cable de red.

*

Tener siempre en cuenta los márgenes especificados tanto para la alimentación como para la medida.

*

Observar en todo momento las condiciones ambientales máximas

especificadas para el aparato.

*

El operador no está autorizado a intervenir en el interior del equipo:

Cualquier cambio en el equipo deberá ser efectuado exclusivamente por personal especializado.

*

El negativo y apantallamiento de los conectores de Entrada / Salida se hallan al potencial de tierra.

No obstruir el sistema de ventilación del equipo.

Seguir estrictamente las recomendaciones de limpieza que se describen en el apartado Mantenimiento.

*

Símbolos relacionados con la seguridad

MANUAL DE INSTRUCCIONES. PROLITE-60

ALTERNA Y CONTINUA

TERMINAL DE TIERRA

TERMINAL DE PROTECCIÓN

TERMINAL A CARCASA

EQUIPOTENCIALIDAD

MARCHA

PARO

PRECAUCIÓN

(Riesgo de choque eléctrico)

PRECAUCIÓN VER MANUAL

FUSIBLE

Página 6 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

2.2 Ejemplos Descriptivos de las Categorías de Sobretensión

Instalaciones de baja tensión separadas de la red. Cat I

Cat II

Cat III

Instalaciones domésticas móviles.

Instalaciones domésticas fijas.

Cat IV Instalaciones

2.3 Precauciones Específicas para la opción OP-A: Fuente de banda ancha

PRECAUCIÓN

Se recomienda no mirar directamente al haz.

La utilización de dispositivos que no sean los especificados en este manual así como la manipulación interna del equipo pueden ser causa de radiación peligrosa.

MANUAL DE INSTRUCCIONES. PROLITE-60

Página 8 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

3 INSTALACIÓN

3.1 Alimentación

El PROLITE-60 es un instrumento portátil alimentado por una batería de NiMh.

Antes de realizar ninguna medida, es preciso asegurarse que la batería está cargada.

3.1.1 Carga de la batería

El equipo dispone de un cargador interno, para alimentar el equipo o cargar la batería.

Hay dos situaciones distintas en la carga de la batería:

1) Con el equipo parado, al conectar el cable de alimentación se inicia un ciclo de carga rápida cuya duración dependerá del estado de la batería.

Para una batería descargada dicho tiempo será de 3,5 h. aproximadamente.

El indicador de carga del panel frontal permanecerá iluminado en ámbar durante este período.

Al finalizar la carga de la batería el indicador se iluminará en color verde indicando que se produce una carga de mantenimiento.

2) Con el equipo en marcha al conectar el cargador éste alimenta el equipo y suministra una carga de mantenimiento quedando el indicador de carga en verde.

ATENCIÓN

Cada vez que se para el equipo o se conecta la alimentación exterior se reinicia un proceso de carga.

Es por ello recomendable descargar la batería utilizando el equipo sin

alimentación exterior para realizar completo el proceso carga / descarga.

ATENCIÓN

El sistema de carga del PROLITE-60 incorpora un sistema de seguridad que no permite la carga a partir de cierto límite de temperatura, pasando la carga a modo mantenimiento, con indicación intermitente ámbar/verde hasta que la temperatura desciende al valor requerido.

PRECAUCIÓN

Antes de utilizar el aparato, asegúrese que es adecuado a la tensión de red.

MANUAL DE INSTRUCCIONES. PROLITE-60

3.1.2 Recomendaciones en el uso de la batería

En caso de prever un largo período de inactividad del equipo es recomendable almacenarlo con la batería descargada.

Al poner en funcionamiento el equipo después de un largo período de inactividad proceder del siguiente modo:

• Poner a cargar el aparato hasta que el indicador luminoso de carga ámbar frontal se ilumine.

• Poner en marcha el equipo, asegurándose que la función AUTO POWER OFF está en OFF, se activará el indicador verde, mantener esta situación durante 10 a 14 horas.

Utilizar el equipo normalmente por lo que después de uno a tres ciclos completos de carga / descarga, dependiendo del tiempo y temperatura de inactividad, la batería habrá sido reacondicionada.

3.2 Instalación y puesta en marcha.

El PROLITE-60 ha sido diseñado para su utilización como equipo portátil.

Una batería totalmente cargada puede alimentar al equipo durante más de tres horas. Cuando aparezca el indicador de batería baja sobre en la pantalla ( batería deberá ser recargada.

), la

Cuando se enciende con una batería totalmente descargada puede ser, que por cargas residuales, el PROLITE-60 llegue a ponerse en marcha, pero el equipo se desconectará automáticamente antes que llegue a aparecer el indicador de batería baja en la pantalla.

Para poner en marcha el equipo, verificar que el interruptor de servicio [21] se encuentra en la posición I (ver figura 2 ”Vista del panel lateral y conectores”) y pulsar la tecla de puesta en marcha [1] en el panel frontal.

Transcurrido el proceso de inicialización interna del equipo, éste permanecerá con la última configuración de medida memorizada.

El protector de pantalla se activa automáticamente transcurridos 5 minutos sin actuar sobre ningún control.

El interruptor de servicio [21] permite por ejemplo dejar el equipo en situación de mínimo consumo por la batería, muy conveniente ante la previsión de un largo período de inactividad.

Antes de apagar a través de este interruptor es conveniente haber apagado previamente por la tecla de puesta en marcha [1] del panel frontal.

3.3 Salvapantallas

Trascurridos cinco minutos sin activar ninguna operación desde el panel frontal la pantalla se muestra en negro con el logotipo de PROMAX flotando en movimiento.

El proceso de barrido se detiene hasta que se active una nueva operación desde el panel frontal.

Página 10 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

4 INSTRUCCIONES DE USO

4.1 Descripción de los Mandos y Elementos

Panel frontal

Figura 1.- Vista frontal

[1]

Tecla de puesta en marcha y desconexión.

[2]

Selecciona el marcador MKR1 o el marcador relativo ∆MKR como marcador activo (sintonizable) y conmuta entre ellos.

[3]

Define el margen de longitudes de onda representado en la escala horizontal entre (10, 20, 50, 100, 200 y 400 nm).

[4]

Selecciona el modo de adquisición de las trazas que se visualizan en pantalla:

Signal, Max Hold, Min Hold y Average.

MANUAL DE INSTRUCCIONES. PROLITE-60

[5]

Define la amplitud de la escala vertical seleccionable entre 10 y 2 dB/div.

[6]

Acceso al menú de funciones de medida y configuración del equipo.

[9] Monitor gráfico TFT en color.

[10] Indicador de carga de la batería.

[11] Indicador de alimentación externa.

[12] Salida óptica (opcional).

Nivel de entrada máximo 10 dBm.

Panel lateral

Página 12

Figura 2.- Vista del panel lateral y conectores.

08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

[20] Conexión de alimentación de red externa.

[21] Interruptor de servicio.

[22] Ventilador.

[23] Altavoz.

[24] Puerto serie RS232C. Conector DB9 macho.

[25] Puerto paralelo. Conector DB25 hembra.

[26] Conector de interfaz Ethernet. RJ45

4.2 Instrucciones básicas de operación

El PROLITE-60 presenta cinco controles de funcionamiento:

Para acceder a cada modo de operación basta con pulsar la tecla correspondiente. Un modo de operación permanece activado mientras el indicador luminoso adyacente a la tecla de selección del modo se encuentre iluminado en color verde.

4.2.1 Control del MARKER:

Este control se activa al pulsar la tecla MARKER [2], aparece en color rojo el campo MKR1 de la pantalla, compuesto por la medida de longitud de onda (λ) y el nivel de potencia (Power) correspondiente a la posición de la marca MKR1.

El giro del selector rotativo [8] permite posicionar esta marca a lo largo del espectro representado. También se puede posicionar directamente el marcador introduciendo un valor dentro del margen de valores aceptados (1250 a 1650 nm) mediante el teclado alfanumérico [7] y pulsando el selector rotativo [8] para validarlo.

Si se pulsa de nuevo la tecla MARKER [2] se activa el marcador relativo MKR∆ que indica los valores diferenciales de longitud de onda (λ) y nivel de potencia (Power) respecto a la posición de la marca principal (MKR1).

MANUAL DE INSTRUCCIONES. PROLITE-60

Figura 3.- Modo MARKER.

Al pulsar el selector rotativo [8] la marca activa se sitúa sobre un máximo del nivel de la traza visualizada.

4.2.2 Control del SPAN:

Al pulsar la tecla SPAN (3) aparece en color rojo el campo de la pantalla indicado como SPAN.

El equipo permite seleccionar entre 6 márgenes de barrido (SPAN 10, 20, 50,

100, 200 y 400 nm). Para seleccionar el margen deseado, pulsar sucesivamente la tecla SPAN (3) o bien introducir el valor numérico mediante el teclado alfanumérico [7] y validarlo pulsando el selector rotativo [8].

Al cambiar el SPAN, la traza visualizada se posiciona en el centro de la pantalla sobre la longitud de onda (λ) indicada por el MKR1.

Página 14

Figura 4.- Selección SPAN 100 nm.

08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

En la parte inferior de la pantalla aparece un pequeño cuadro con la representación del espectro completo (Full Span) con el fin de localizar en todo momento la zona del espectro correspondiente a la pantalla principal que aparece marcada por un recuadro blanco de líneas discontinuas.

4.2.3 Control de TRACE:

Cuando se pulsa la tecla TRACE [4] aparece en rojo el campo de la pantalla donde se indica el tipo de medida a representar para la señal de entrada.

En la parte derecha de la pantalla se muestran, mediante una columna de iconos numéricos, las trazas disponibles para operar:

Traza 0: Representa la traza de medida de la señal de entrada, que es refrescada a partir de cada barrido.

Trazas 1 a 9: Representan trazas que han sido memorizadas anteriormente.

El PROLITE-60 permite realizar las siguientes operaciones con las trazas:

1.- Memorización de trazas:

Para salvar la medida (traza 0) y asignarla a una posición de memoria, pulsar la tecla numérica correspondiente a la traza que se desee memorizar mientras se mantiene pulsado el selector rotativo [8]. Por ejemplo, si se pulsa el selector rotativo [8] y, a continuación la tecla número 7, en la posición de memoria correspondiente a la traza 7 se guardará el valor de la medida representada por la traza 0 en ese instante.

2.- Visualización de trazas:

La traza activa corresponde a la última traza seleccionada. Se visualiza en la pantalla y aparece indicada con una flecha en la columna de iconos cuadrados de la parte derecha de la pantalla. Sobre la traza activa actúan los marcadores [2].

Para activar la representación de una traza previamente memorizada pulsar la tecla numérica que corresponda al número de traza que se desea visualizar.

La traza aparecerá en pantalla y los cursores permanecerán asignados a dicha traza. Para desactivarla, pulsar de nuevo la tecla numérica correspondiente y la traza dejará de visualizarse en la pantalla.

En todo momento se visualizarán aquellas trazas previamente memorizadas que hayan sido seleccionadas. Cada traza aparece dibujada en la pantalla con el mismo color que el icono correspondiente de la columna de iconos que representan las trazas en la parte derecha de la pantalla. Se visualizan aquellas trazas cuyo icono aparezca resaltado en color.

MANUAL DE INSTRUCCIONES. PROLITE-60

3.- Representación de medidas relativas:

Para visualizar una traza en modo relativo, es decir una traza que representa la relación entre la medida de la señal de entrada (traza 0) y la traza (de 1 a 9) que se haya seleccionado como activa:

1.- Activar la traza que se desee relativizar (del 1-9).

2.- Pulsar la tecla [*].

Aparecerá un icono cuadrado

*

con el color correspondiente a la traza con la que se ha relativizado la señal de entrada.

Para salir del modo traza, pulsar la tecla [*].

4.- Selección del tipo de medida (traza 0):

Al pulsar de forma secuencial la tecla TRACE [4] es posible seleccionar el tipo de adquisición de la señal de entrada:

Señal

Max Hold D Memorización de los máximos de la señal, aparece el símbolo

“}“ en el icono identificador de la traza.

Min Hold D Memorización de los mínimos de la señal, aparece el símbolo

“~“ en el icono identificador de la traza.

Average

D

Promedio de valores de la señal. Aparece el símbolo (µ) en el icono identificador de la traza.

5.- Captura de imágenes:

Cuando se hace un doble clic sobre el selector rotativo [8], el PROLITE-60 guarda una imagen en formato (JPEG) de la pantalla completa.

A esta imagen le será asignado un valor numérico y se podrá recuperar accediendo al WEB SERVER mediante un PC conectado a la red local.

Página 16

Figura 5.- Control de TRACE.

08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

4.2.4 Control de AMPLITUDE:

La tecla AMPLITUDE [5] permite acceder a la selección de la sensibilidad vertical del instrumento.

La selección de 10 a 2 dB se realiza pulsando la tecla AMPLITUDE [5] o pulsando el selector rotativo [8].

Cuando se ha seleccionado 10 dB/div, el giro del selector rotativo [8] permite desplazar los cursores horizontales que limitan el área del espectro que se visualizará al pasar a 2 dB/div. Si se ha activado 2 dB/div, el giro del selector rotativo [8] selecciona el rango de niveles deseados.

Figura 6.- Selección AMPLITUDE 10 dB/div.

Las líneas-guía horizontales sólo aparecen en pantalla cuando el modo

AMPLITUDE está seleccionado.

MANUAL DE INSTRUCCIONES. PROLITE-60

Página 18 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

5 Modo FUNCTIONS (CONFIGURATION MENU):

5.1 Descripción

Al pulsar la tecla FUNCTIONS [6] se accede al menú de las funciones del

PROLITE-60, entre las que se incluyen las funciones de configuración de los parámetros básicos de trabajo del analizador óptico:

Figura 7.- FUNCTIONS. Menú principal.

Menú Settings:

Menú Upgrade:

Configuración de las trazas e imágenes capturadas, configuración de la línea de referencia y selección del idioma, hora / fecha, conexión a red de datos, sonido, desconexión automática y cambio de clave de acceso al Web Server.

Actualización manual (puerto serie o Ethernet) o actualización automática (Ethernet).

Ventana About: Información sobre el número de serie del equipo y versión del software.

Así como las siguientes funciones de medida para aplicaciones específicas:

LED MEASURE: Caracterización de las fuentes de luz LED (diodos de fuentes de luz).

DWDM MEASURE: Permite realizar un análisis espectral de sistemas ópticos con multiplexación por división densa y no densa de la longitud de onda (DWDM y CWDM).

DFB MEASURE: Caracterización de las fuentes DFB (láser de realimentación distribuida).

FP MEASURE: Caracterización de las fuentes FP (láser Fabry-Perot).

OA MEASURE:

MANUAL DE INSTRUCCIONES. PROLITE-60

Comprobación de la respuesta en longitud de onda (λ) de los amplificadores ópticos OA.

Figura 8.- FUNCTIONS. Ejemplo de aplicación de la función OA MEASURE.

5.2 Funciones de configuración del equipo

Las funciones que se utilizan para configurar los parámetros de operación del analizador de espectros ópticos PROLITE-60, aparecen representadas mediante iconos sobre la primera fila de la ventana que se muestra al pulsar la tecla

FUNCTIONS [6]. Girar el selector rotativo [8] hasta situar el cursor de selección sobre el icono de la función deseada y finalmente pulsar el selector rotativo [8] para activarla.

Página 20

Figura 9.- FUNCTIONS. Menú de settings.

08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

Girar y pulsar el selector rotativo [8] para seleccionar la opción deseada:

Configure Traces: Selecciona la traza a editar (1 a 9), permite eliminar la traza seleccionada e informa del instante de su registro.

Configure Images: Selecciona la imagen a editar (1 a 19), permite eliminar la imagen seleccionada e informa del instante de su captura.

Configure Ref. Line: Define el nivel de la línea de referencia entre —70 y 10 dBm en saltos de 1 dB. Permite activar o desactivar la representación de la línea de referencia.

Global Adjustments: Activa el menú de ajustes globales del equipo.

Figura 10.- Menú Global Adjustments (Menú SETTINGS).

Girar y pulsar el selector rotativo [8] para seleccionar la opción deseada:

Change Language: Selecciona el idioma.

Configure Date/Time: Muestra y permite modificar mediante el teclado numérico la hora y la fecha.

Network adjustments: Permite introducir la dirección IP del equipo, la máscara de red, la dirección del gateway y la dirección del servidor proxy.

También permite la asignación dinámica de direcciones IP mediante DHCP.

Configure Sound:

Auto-Power OFF:

Activa o desactiva el altavoz y ajusta el volumen de sonido.

Establece la desconexión como Manual o Automática, en el caso de seleccionar Desconexión Automática se puede especificar el intervalo de temporización entre 1 y 240 minutos.

MANUAL DE INSTRUCCIONES. PROLITE-60

Remote Password:

Reestablece al valor por defecto la clave de acceso al modo de control remoto.

Figura 11.- Menú UPGRADE.

Girar y pulsar el selector rotativo [8] para seleccionar la opción deseada:

Manual Upgrade: Selecciona la actualización manual a través del puerto serie

(RS-232C) [24] o la conexión Ethernet [26].

Automatic Upgrade: Selecciona la actualización automática a través de la conexión

Ethernet [26].

NOTA

Para activar la actualización automática, previamente se deben configurar adecuadamente los parámetros de red y seleccionar: FUNCTIONS UPGRADE

AUTOMATIC.

El PROLITE-60 se conecta al WEB SITE de PROMAX y busca la última versión de software disponible.

Para realizar una actualización manual, previamente se debe cargar en el equipo el archivo de la versión de software correspondiente, siguiendo los pasos que se describen a continuación:

En caso de utilizar el puerto RS-232C:

1. Conectar un cable serie entre el PC y el PROLITE-60.

Página 22 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

2. Ejecutar en el PC un emulador de terminal (p.e.: Hyperterminal, TeraTerm, etc.,.) y configurar la conexión a 19200 bauds, 8 bits, sin paridad y 1 bit de stop.

3. Pulsar ENTER, cuando solicite el nombre de usuario (default login) introducir: serial

4. Enviar desde el emulador el archivo correspondiente de extensión: .asc y pulsar Ctrl.+D.

En caso de utilizar la conexión Ethernet:

1. Configurar adecuadamente los parámetros de red.

2. Acceder al WEB Server del PROLITE-60 y seleccionar la opción Upgrade.

3. Seleccionar la opción Update Firmware (manual)

4. Buscar en el PC el archivo de la nueva versión de extensión: .asc

5. Seleccionar la opción Upload

Ahora ya se puede activar la actualización manual del PROLITE-60 (Seleccionar

FUNCTIONS -> UPGRADE -> MANUAL).

Figura 12.- About.

Ofrece información sobre el número de serie del equipo y versión del software.

MANUAL DE INSTRUCCIONES. PROLITE-60

5.3 Funciones de medida del equipo

El analizador de espectros ópticos PROLITE-60 presenta varias funciones de medida diseñadas para aplicaciones específicas que aparecen representadas mediante iconos sobre la segunda fila de la ventana que se muestra pulsar la tecla FUNCTIONS

[6]. Girar el selector rotativo [8] hasta situar el cursor de selección sobre el icono de la función deseada y finalmente pulsar el selector rotativo [8] para activarla.

5.3.1 Función LED MEASURE

Figura 13.- Medida de fuentes LED.

Parámetros de medida

Peak lambda Longitud de onda en que se encuentra el valor de pico del espectro de la fuente LED.

Mean Lambda

) Es el centro de masas correspondiente a los puntos de la traza.

BW

Power

Ancho de banda medido a 3 dB.

Resultado de la integración de la energía en el margen de longitudes de onda representado.

Peak Amplitude

Nivel de potencia para el pico de la fuente LED.

Sigma (σ)

FWHM

File

Valor equivalente del ancho espectral del LED para una distribución Gausiana, basada en el (λ

) definido anteriormente.

(Full Width at Half Maximum) define el ancho espectral para los puntos de potencia-mitad (caída de -3dB) del LED, para una distribución Gausiana basada en el (λ

) y la (σ) definidas.

Acceso al menú de archivo de datos.

Página 24 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

Figura 14.- Menú de archivo de datos

Opciones

Save Values

Manage Files

Select

Load

Close Menu

Exit

Delete

Guarda en un archivo los parámetros de medida registrados para la traza en la pantalla del analizador de espectros ópticos.

Muestra la lista de archivos de datos almacenados en la memoria.

Selecciona un archivo de datos donde se han guardado los parámetros de medida descritos anteriormente.

Permite borrar un archivo de datos.

Carga los datos del archivo de datos.

Abandona el menú de archivo de datos.

Abandona la función de medida.

5.3.2 Función DWDM MEASURE

MANUAL DE INSTRUCCIONES. PROLITE-60

Figura 15.- Medida de fuentes WDM.

Parámetros de medida

Para cada portadora WDM (Wavelength Division Multiplexing):

λ

Longitud de onda donde se encuentra situada (nm)

PWR Nivel de potencia (dBm).

SNR Medida de la relación señal-ruido óptica (SNR).

Para todas las portadoras:

Min. Número de la portadora con un nivel medido mínimo.

Max.

Tilt

Número de la portadora con un nivel medido máximo.

Pendiente de la recta que mejor se ajusta a las portadoras detectadas según el criterio de mínimos cuadrados, sus unidades son dB/nm.

Peak to peak Desviación pico a pico, se define como la diferencia entre la potencia de la portadora Máx. y la potencia de la portadora Mín. (dB).

SETUP Menu Acceso al menú de configuración de los parámetros de medida

Página 26 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

Opciones

Figura 16.- Menú de configuración de los parámetros de medida

Start Lambda (nm) Establece la longitud de onda inicial del barrido.

Stop Lambda (nm) Establece la longitud de onda final del barrido.

Peak Excursion (dB) Selecciona el valor de la excursión de pico. Es el recorrido en amplitud que la traza debe describir desde el mínimo hasta el máximo para ser considerada como un pico. Valores bajos permiten detectar un mayor número de señales pero también puede verse afectado por el nivel de ruido de fondo.

Peak Threshold (dBm) Selecciona el valor umbral de pico. Los niveles de potencia por debajo de este umbral no se consideran durante la búsqueda de picos.

Noise Level (nm) Selecciona la longitud de onda para la medida del ruido, cuyo valor es utilizado en la medida de SNR.

Close Menu

Abandona el menú de configuración de los parámetros de medida.

Acceso al menú de archivo de datos. File

Opciones

Save Values

Manage Files

Guarda en un archivo los parámetros de medida registrados para la traza en la pantalla del analizador de espectros ópticos.

Muestra la lista de archivos de datos almacenados en la memoria.

Select

Selecciona un archivo de datos donde se han guardado los parámetros de medida descritos anteriormente.

MANUAL DE INSTRUCCIONES. PROLITE-60

Delete

Permite borrar un archivo de datos.

Load

Carga los datos del archivo de datos.

Close Menu

Scroll

Abandona el menú de archivo de datos.

Permite desplazar la ventana de visualización de los datos de medidas de los parámetros de la portadoras

WDM detectadas.

Abandona la función de medida Exit

5.3.3 Función DFB MEASURE (Distributed Feedback)

Figura 17.- Medida de fuentes DFB

Parámetros de medida

Peak Wavelength Es la longitud de onda cuya amplitud es máxima.

Peak Amplitude Nivel de potencia para la componente espectral de pico de la fuente DFB.

BW Ancho de banda de la principal componente espectral de la fuente

DFB. Debido a la anchura del espectro que presentan la mayoría de fuentes DFB no moduladas, la medida estará determinada por la resolución del ancho de banda del analizador de espectros

ópticos.

SMSR (Side Mode Suppression Ratio) Es la relación de amplitud entre la principal componente espectral y el modo lateral mayor (no necesariamente el primer modo lateral) de la traza actual.

Página 28 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

Mode Off

Center Off

Stop Band

(Mode Offset) Separación en nm entre la principal componente espectral y el modo mayor más próximo de la traza actual. Los valores negativos indican que la longitud de onda del modo mayor más próximo es inferior a la del modo principal, y los valores positivos que es superior.

(Center Offset) Indica cómo se ajusta el modo principal al espaciado definido por la stop band. Este valor es la diferencia entre la longitud de onda de la componente espectral principal y la media de las longitudes de onda de la componente mayor y menor de la stop band.

Es el espaciado en longitud de onda existente entre los modos laterales superior e inferior adyacentes al modo principal.

Acceso al menú de archivo de datos. File

Opciones

Save Values

Manage Files

Select

Delete

Load

Close Menu

Exit

Guarda en un archivo los parámetros de medida registrados para la traza en la pantalla del analizador de espectros ópticos.

Muestra la lista de archivos de datos almacenados en la memoria.

Selecciona un archivo de datos donde se han guardado los parámetros de medida descritos anteriormente.

Permite borrar un archivo de datos.

Carga los datos del archivo de datos.

Abandona el menú de archivo de datos.

Abandona la función de medida

MANUAL DE INSTRUCCIONES. PROLITE-60

5.3.4 Función FP MEASURE (Fabry-Perot)

Figura 18.- Medida de fuentes FP.

Parámetros de medida

Mean Lambda

) Es el centro de masas correspondiente a los puntos de la traza.

Peak lambda

Mode Spacing

FWHM

Power

Longitud de onda donde se encuentra el valor de pico del espectro de la fuente FP.

Es el espaciado medio en longitud de onda entre las componentes espectrales individuales de la fuente FP.

(Full Width at Half Maximum) define el ancho espectral para los puntos de potencia-mitad (caída de -3dB) de la fuente FP, para una distribución Gausiana basada en el (λ

) y la (σ) definidas.

Resultado de la integración de la energía en el margen de longitudes de onda representado.

Peak Amplitude

Nivel de potencia para la componente espectral de pico de la fuente FP.

Sigma (σ) Valor equivalente del ancho espectral de la fuente FP para una distribución Gausiana, basada en el (λ

) definido anteriormente.

Acceso al menú de archivo de datos. File

Opciones

Save Values

Manage Files

Guarda en un archivo los parámetros de medida registrados para la traza en la pantalla del analizador de espectros ópticos.

Muestra la lista de archivos de datos almacenados en la memoria.

Página 30 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

Select

Selecciona un archivo de datos donde se han guardado los parámetros de medida descritos anteriormente.

Delete

Load

Permite borrar un archivo de datos.

Carga los datos del archivo de datos.

Close Menu

Abandona el menú de archivo de datos.

Exit Abandona la función de medida

5.3.5 Función OA MEASURE (Optical Amplifiers)

Figura 19.- Medida de amplificadores ópticos.

PROCEDIMIENTO DE MEDIDA

1.- Conectar la fuente a la entrada del analizador de espectros ópticos (OSA) y pulsar

Start.

Se registra la respuesta espectral de la fuente óptica que aparece dibujada en pantalla.

2- Conectar la salida del amplificador a la entrada del analizador de espectros ópticos

(OSA) y pulsar Start.

Se representa la respuesta espectral del amplificador óptico en color verde, que aparece superpuesta con la anterior para su comparación.

MANUAL DE INSTRUCCIONES. PROLITE-60

Figura 20.- Menú de configuración de los parámetros de medida.

Parámetros de medida

Para cada portadora WDM (Wavelength Division Multiplexing):

λ

Longitud de onda donde se encuentra situada (nm)

PWR

SNR

Nivel de potencia (dBm).

Medida de la relación señal-ruido óptica (SNR).

Diferencia en cada

λ medida entre la salida y la entrada. GAIN

SETUP Menu Acceso al menú de configuración de los parámetros de medida

Opciones

Start Lambda (nm) Establece la longitud de onda inicial del barrido.

Stop Lambda (nm) Establece la longitud de onda final del barrido.

Peak Excursion (dB) Selecciona el valor de la excursión de pico. Es el recorrido en amplitud que la traza debe describir desde el mínimo hasta el máximo para ser considerada como un pico. Valores bajos permiten detectar un mayor número de señales pero también puede verse afectado por el nivel de ruido de fondo.

Peak Threshold (dBm) Selecciona el valor umbral de pico. Los niveles de potencia por debajo de este umbral no se consideran durante la búsqueda de picos.

Noise Level (nm) Selecciona la longitud de onda para la medida del ruido, cuyo valor es utilizado en la medida de SNR.

Close Menu

File

Abandona el menú de configuración de los parámetros de medida.

Acceso al menú de archivo de datos.

Página 32 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

Opciones

Save Values

Guarda en un archivo los parámetros de medida registrados para la traza en la pantalla del analizador de espectros ópticos.

Manage Files

Muestra la lista de archivos de datos almacenados en la memoria.

Select

Selecciona un archivo de datos donde se han guardado los parámetros de medida descritos anteriormente.

Delete

Load

Permite borrar un archivo de datos.

Carga los datos del archivo de datos.

Close Menu

Exit

Abandona el menú de archivo de datos.

Abandona la función de medida

MANUAL DE INSTRUCCIONES. PROLITE-60

Página 34 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

6 Control REMOTO

Permite el acceso remoto a las funciones del equipo mediante una red ethernet, para ello:

1) Configurar los parámetros de red local en el PROLITE-60 (IP, tipo de servidor, etc.,.).

2) Conectar PROLITE-60 a la red.

3) Conectarse a la red, y acceder al Web Server del equipo mediante un navegador introduciendo la IP especificada en la configuración.

Figura 21.- Web Server PROLITE-60.

El Web Server del PROLITE-60 ofrece las siguientes funciones:

Traces:

Images:

Obtención de datos de medida de las trazas memorizadas.

Visualización de trazas previamente capturadas.

Remote Mode: Control remoto de las principales funciones del PROLITE-60.

Upgrade: Permite actualizar la versión del firmware del equipo.

MANUAL DE INSTRUCCIONES. PROLITE-60

La opción Recover Traces permite recuperar los datos relativos a las trazas de medida memorizadas, para cada tipo de medida: WDM, DFB, LED, FP o OA. Se puede llegar a memorizar hasta un máximo de nueve trazas, y al seleccionar aparecerá un listado de todos los valores medidos.

Figura 22.- Web Server PROLITE-60. Recupera datos de trazas memorizadas.

El PROLITE-60 puede almacenar en la memoria hasta diecinueve imágenes en formato JPEG, correspondientes a las trazas visualizadas en la pantalla del equipo.

Cuando se hace clic sobre una traza memorizada, ésta se muestra en el monitor del

Web Server.

Figura 23.- Web Server PROLITE-60. Recupera imágenes de trazas memorizadas.

Página 36 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

6.3 Modo Remoto (REMOTE MODE)

Permite acceder al modo de control remoto del PROLITE-60. El usuario puede seleccionar trazas y ordenar operaciones desde un ordenador remoto. El acceso al modo de control REMOTO desde el Web Server requiere de un ID (nombre del usuario) y una clave de acceso (por defecto: abcdefg).

Figura 24.- Web Server PROLITE-60. Acceso al modo de control remoto.

Permite operar de forma remota las funciones básicas del equipo: MARKER,

SPAN, TRACE, AMPLITUDE e introducir valores numéricos como si se actuase directamente sobre los controles del panel frontal del equipo.

Para operar con las trazas seleccionar mediante el ratón cada traza a visualizar con un clic sobre el teclado alfanumérico que aparece representado en la pantalla del

Web Server del PROLITE-60.

Al hacer clic sobre el botón los datos en pantalla.

(PLAY) el equipo realiza una medida y actualiza

El botón

permite actualizar los datos en pantalla. De esta forma, se actualiza la información en el caso que un mismo equipo esté siendo operado por diferentes usuarios remotamente.

Save trace: Permite memorizar las trazas que aparecen en pantalla en la memoria del equipo.

Last Users: Listado de los últimos usuarios que han accedido al equipo y los comandos que se han ejecutado.

MANUAL DE INSTRUCCIONES. PROLITE-60

Figura 25.- Web Server PROLITE-60. Control de trazas en modo remoto.

Permite que el usuario descargue en el equipo un archivo que contenga una actualización del firmware. De este modo, es posible una actualización manual del

firmware desde el menú UPGRADE.

Figura 26.- Web Server PROLITE-60. Recupera una versión del firmware actualizado.

Página 38 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

7 MANTENIMIENTO

Esta parte del manual describe los procedimientos de mantenimiento y localización de averías.

7.1 Métodos de mantenimiento

El mantenimiento normal a efectuar por el usuario consiste en la limpieza de la caja. Todas las demás operaciones deberán ser efectuadas por los agentes autorizados o por personal especializado en el servicio de instrumentos.

7.1.1 Limpieza de la caja.

PRECAUCIÓN

No se use para la limpieza hidrocarburos aromáticos o disolventes clorados. Estos

productos pueden atacar a los materiales utilizados en la construcción de la caja.

La caja se limpiará con una ligera solución de detergente con agua y aplicada mediante un paño suave humedecido. Secar completamente antes de volver a usar el equipo.

PRECAUCIÓN

Para la limpieza de los contactos utilizar un paño seco. No utilizar nunca un paño húmedo o mojado.

PRECAUCIÓN

No usar para la limpieza del panel frontal y en particular de los visores, alcohol o sus derivados, estos productos pueden atacar las propiedades mecánicas de los materiales y disminuir su tiempo de vida útil.

7.2 Componentes no sustituibles por el usuario

7.2.1 Fusibles no sustituibles por el usuario

F001:

F002:

FUS 7 A T 125 V

FUS 7 A T 125 V

SMD

SMD

MANUAL DE INSTRUCCIONES. PROLITE-60

Página 40 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

APÉNDICE A: Guía Rápida de Utilización

Cómo operar con los marcadores (MARKER)

Marcador absoluto MKR1

1. Pulsar [2] para activar el campo MKR1.

2. Seleccionar la longitud de onda (λ) del marcador MKR1 mediante el teclado alfanumérico [7], o girando directamente el selector rotativo [8].

3. Al pulsar el selector rotativo [8], el marcador MKR1 se sitúa directamente sobre el valor máximo de la traza activa, que corresponde a la traza que se ha seleccionado para visualizar en pantalla (posiciones 0 a 9 de la columna derecha de iconos cuadrados ).

Marcador relativo MKR

1. Pulsar [2] otra vez, para activar el ∆MKR.

2. Seleccionar la longitud de onda (λ) del marcador ∆MKR mediante el teclado alfanumérico [7], o girando directamente el selector rotativo [8].

3. Al pulsar el selector rotativo [8], el marcador ∆MKR se sitúa directamente sobre el valor máximo de la traza activa.

Cómo operar con el Span (SPAN)

1. Pulsar [3] para activar el campo Span.

2. Seleccionar el valor numérico mediante el teclado alfanumérico [7]: (10, 20, 50,

100, 200, 400 nm).

3. También puede seleccionar el valor del Span pulsando la tecla pulsar esta tecla consecutivamente el valor cambia de forma cíclica.

[3]. Al

Cada vez que cambia el Span, el nuevo Span aparece centrado sobre la longitud de onda (λ) del marcador MKR1.

MANUAL DE INSTRUCCIONES. PROLITE-60

Cómo operar con las trazas (TRACES)

1. Pulsar [4] para activar el campo Trace.

2. En lado derecho de la pantalla aparece una columna con 11 cuadrados pequeños de colores. Cada cuadrado corresponde a una traza coloreada.

Cuadrado (0): Corresponde a la traza de datos (color verde). Esta traza corresponde al valor de la señal de entrada medida que se refresca en cada barrido.

Al pulsar la tecla [4] cuando el campo Trace está activado (en color rojo), es posible seleccionar diferentes tipos de medida: SIGNAL —> MAX. HOLD -> MIN.

HOLD -> AVERAGE ->

El modo seleccionado será visualizado en la pantalla de medida excepto para el modo SIGNAL (operación normal).

Cuadrados (1)-(9): Corresponden a trazas memorizadas. Es posible copiar la traza de datos (0) a cualquiera de las otras trazas (desde la 1 a la 9).

El proceso es sencillo. Siempre con el campo Trace activo (en color rojo), pulsar el selector rotativo [8] simultáneamente con una tecla numérica [7]. Por ejemplo, si pulsa el selector rotativo [8] + la tecla número (7), la traza (7) tomará el mismo valor que la traza de datos (0).

Cualquier traza memorizada puede ser visualizada y eliminada de la pantalla, simplemente pulsando la tecla numérica correspondiente.

Cuadrado (*): Corresponde a la traza relativa que permite memorizar la diferencia entre la traza de datos (0) y la traza activa. Para visualizar esta traza, activar previamente cualquiera de las trazas (1) - (9) y pulsar la tecla (

*

).

Cómo operar con la amplitud (AMPLITUDE)

1. Pulsar [5] para activar el campo Scale.

2. Seleccionar 10 dB/div o 2 dB/div utilizando el teclado alfanumérico [7] o con la propia tecla [5].

3. En el modo de 10 dB/div aparecen dos líneas discontinuas horizontales que indican el área de vista de la pantalla a 2 dB/div.

Página 42 08/2007

MANUAL DE INSTRUCCIONES. PROLITE-60

Cómo guardar pantallas de trazas como archivos JPEG

1. Pulsar dos veces el selector rotativo [8] mientras el modo Trace se encuentra activado.

2. Se crea un archivo JPEG que contiene la información de la pantalla completa.

3. Es posible acceder a esta imagen a través del

WEB SERVER

.

Cómo acceder al

WEB SERVER

1. Primero es necesario conectar el PROLITE-60 a una red Ethernet o directamente a un ordenador utilizando un cable adecuado.

2. Configurar los parámetros de red (IP, SERVIDOR PROXY, etc.,.) pulsar la tecla

FUNCTION —> SETTING -> GLOBAL ADJUSTMENTS -> NETWORK ADJ.

desde el ordenador utilizando un navegador de Internet

(IE, FireFox, Netscape...).

USER’S MANUAL. PROLITE-60

T A B L E O F C O N T E N T S

1 GENERAL.................................................................................................................. 1

1.1

Description .......................................................................................................... 1

1.2

Specifications ...................................................................................................... 2

2 SAFETY RULES........................................................................................................ 5

2.1

Generals ............................................................................................................. 5

2.2

Descriptive Examples of Over-Voltage Categories ............................................. 7

2.3

Specific cautions for the OP-A option: Broadband source. ................................. 7

3 INSTALLATION ......................................................................................................... 9

3.1

Power supply....................................................................................................... 9

3.1.1

Battery charge............................................................................................... 9

3.1.2

Recommendations for using the battery ..................................................... 10

3.2

Installation and start-up. .................................................................................... 10

3.3

Sreen saver. ...................................................................................................... 11

4 OPERATING INSTRUCTIONS................................................................................ 11

4.1

Description of the controls and elements .......................................................... 11

4.2

Operating basic instructions .............................................................................. 13

4.2.1

MARKER control:........................................................................................ 13

4.2.2

SPAN control: ............................................................................................. 14

4.2.3

TRACE control: ........................................................................................... 15

4.2.4

AMPLITUDE control:................................................................................... 17

5 FUNCTIONS MODE (CONFIGURATION MENU):.................................................. 19

5.1

Description ........................................................................................................ 19

5.2

Equipment configuration functions .................................................................... 20

5.2.1

SETTINGS menu ........................................................................................ 20

5.2.2

UPGRADE menu ........................................................................................ 22

5.2.3

ABOUT window........................................................................................... 23

5.3

Equipment measurement functions................................................................... 23

5.3.1

LED MEASURE function............................................................................. 24

5.3.2

DWDM MEASURE function ........................................................................ 26

5.3.3

DFB MEASURE function (Distributed Feedback) ....................................... 28

5.3.4

FP MEASURE function (Fabry-Perot)......................................................... 29

5.3.5

OA MEASURE function (Optical Amplifiers) ............................................... 31

6 WEB SERVER......................................................................................................... 33

6.1

TRACES function .............................................................................................. 33

6.2

IMAGES function............................................................................................... 34

6.3

REMOTE MODE function.................................................................................. 35

6.4

UPGRADE function ........................................................................................... 36

7 MAINTENANCE....................................................................................................... 37

7.1

Method of maintenance..................................................................................... 37

7.1.1

Cleaning the cover. ..................................................................................... 37

APPENDIX A: QUICK REFERENCE GUIDE ................................................................ 37

7.2

Components which user can not replace .......................................................... 37

7.2.1

Not replaceable fuses by user .................................................................... 37

USER’S MANUAL. PROLITE-60

USER’S MANUAL. PROLITE-60

FIELD OPTICAL SPECTRUM ANALYSER

PROLITE-60

1 GENERAL

1.1 Description

The PROLITE-60 is a field optical spectrum analyser, an instrument portable, powered through batteries. It is suitable for multiple applications, among others the verification of WDM (Wavelength Division Multiplexing) / CWDM

(Coarse Wavelength

Multiplexing Division) telecommunication systems, in addition by means of several options and accessories also available, it can be used in applications of reflectometry, analysis of materials, optical fibre sensors, verification of photonics devices such as filters, attenuators, couplers, insulators and other optical components.

The instrument includes specific functions that they allow it to characterise the response of different optical transmission systems, as for example the LEDs, DWDM,

DFB, FP, OA measurements. All these measurements are configurable through the accessible parameters by means of graphical menus on a user intuitive screen.

In the optical spectrum analysis mode it offers two movable cursors, which act as markers throughout the wavelength exploration range.

The SPAN is configurable from 10 nm to 400 nm in order to facilitate the spectrum visualization in the horizontal scale, also on the vertical scale can be set 10 dB or 2 dB divisions to obtain a greater resolution for measurements.

It offers ten memory positions to store the previously registered traces and to work later. The acquired measures can be reviewed, be transferred to a PC or be printed at any time. Also, it allows the remote access to the data registered through a

TCP/IP network (Web Server).

The PROLITE-60 gives an answer to the necessities of making selective measurements in wavelength, for telecommunication operators, which transmit multiple wavelengths through a same optical fibber simultaneously, in order to profit the currently deployed networks.

In the PROLITE-60 design a special care has been taken to create a practical, accurate, yet easy-to-use device. A complete alphanumeric keypad facilitates direct access to the various operating modes. Once accessed, ambidextrous navigation and selection keys can be used to easily modify any parameter of the measurements.

The integration of all of these functions in a device with lightweight and small size, with ergonomic and robust design, make the PROLITE-60 an unbeatable fieldwork tool.

1.2 Specifications

WAVELENGTH

Wavelength range

USER’S MANUAL. PROLITE-60

Optical resolution

Accuracy

From 1250 to 1650 nm.

0.15 nm.

± 0.5 nm.

POWER

1

Dynamic range

From -60 dBm to 10 dBm.

Accuracy

± 0.50 dB.

Stability

Optical signal noise ratio (OSNR)

Selective to 1550 nm

at 25 GHz (± 0.2 nm)

at 50 GHz (± 0.4 nm)

at 100 GHz (± 0.8 nm)

POLARIZATION

18 dB (min.)

25 dB (min.)

30 dB (min.)

SWEEP CYCLE

CONNECTORS

Standard optical

PRESENTATION MONITOR

Monitor

COMMUNICATIONS INTERFACE

FC/PC

TFT colour 6,4 “

Series port RS232

POWER SUPPLY

Voltage

Low battery indicator

Autonomy

Auto power Off

Battery charge

Equipment consumption

100-240 V AC

Graphic indication on the display:

3 h approx.

Configurable time out (from 1 to 240 min.)

By fast internal charger.

36 W.

1

Valid values for optical fibres (9/125 µm) and FC/PC connector.

Page 2 09/2007

USER’S MANUAL. PROLITE-60

ENVIRONMENTAL CONDITIONS

This equipment could be used on the following environmental conditions, in these conditions the specifications could also be applied:

Altitude Up to 2000 metres.

Temperature range From

Maximum relative humidity

MECHANICAL FEATURES

80 % (up to 31 °C), decreasing lineally up to 50% at 40 °C.

Dimensions

Weight

INCLUDED ACCESSORIES

CA-005

0 FD0453

OPTIONS

Transport cover.

294 W. x 126 H. x 274 D. mm

5,7 kg.

A

73

72

71

70

SLED -1566 nm light source (Ask for available configurations)

Power

BW

3dB

- 8 dBm

Optical connector FC — PC

Optical connector SC — PC

Optical connector FC — E2000

Optical connector FC — ST

(Ask for available APC connectors)

USER’S MANUAL. PROLITE-60

Page 4 09/2007

USER’S MANUAL. PROLITE-60

2 SAFETY RULES

2.1 Generals

*

This is a class I equipment, for safety reasons plug it to a supply line with the corresponding ground terminal.

*

This equipment can be used in Over-Voltage Category II installations and

Pollution Degree 2 environments.

*

When using some of the following accessories use only the specified ones to ensure safety.

Mains cord

*

Observe all specified ratings both of supply and measurement.

*

Use this instrument under the specified environmental conditions.

*

The user is not authorised to manipulate inside the instrument:

Any change on the equipment should be carried out by qualified personnel.

*

The negative et shielding for Input / Output connectors are connected to ground potential.

*

Do not obstruct the ventilation system.

*

Follow the cleaning instructions described in the Maintenance paragraph.

*

Symbols related with safety:

DIRECT AND ALTERNATING

FRAME TERMINAL

USER’S MANUAL. PROLITE-60

EQUIPOTENTIALITY

(Class II protection)

CAUTION

(Risk of electric shock)

CAUTION REFER TO MANUAL

FUSE

Page 6 09/2007

USER’S MANUAL. PROLITE-60

2.2 Descriptive Examples of Over-Voltage Categories

Low voltage installations isolated from the mains.

Cat. II

Cat. III

Portable domestic installations.

Fixed domestic installations.

2.3 Specific cautions for the OP-A option: Broadband source.

CAUTION

It is recommended not to look straight at the light beam.

The use of devices that are not specified by this manual and the internal manipulation of the instrument may cause harmful radiation.

USER’S MANUAL. PROLITE-60

Page 8 09/2007

USER’S MANUAL. PROLITE-60

3 INSTALLATION

The PROLITE-60 is a portable instrument powered by a built-in NiMh rechargable battery. Before taking any measurement, the user should make sure that the battery is fully charged.

The instrument has an internal charger to power or to charge the instrument.

There are two different situations on battery charge:

1) With the instrument stopped, on having connected the mains cord, begins a cycle of fast load which duration will depend on the battery state. For an empty battery this time will be of 3,5 h. approximately. The charging battery indicator on the frontal panel will remain lit in amber colour during this period of time.

When the battery charging is completed, the light will change to green, indicating that a maintenance charge is taking place.

2) When the instrument is operating and connects the adapter, this one powers the equipmen and provides a battery maintenance charge while the charging indicator remains lit in green colour.

ATTENTION

Whenever the equipment is power off or the external voltage adapter is connected a battery charging process restarts.

It is for that reason recommendable to discharge the battery using instrument

without external power supply to make complete the charge / discharge process.

ATTENTION

The charge system of PROLITE-60 incorporates a security system that does not allow the process charge from certain temperature limit, begining the maintenance charge instead, with indicator flashing in green/amber until the temperature downs to the required value.

CAUTION

Before using the instrument, make sure that the adapter is suitable for the mains voltage.

USER’S MANUAL. PROLITE-60

3.1.2 Recommendations for using the battery

In case of anticipating a long period of inactivity for the equipment it is recommended to store it with the battery discharged.

When the equipment starts the operation after a long period of inactivity to follow next steps:

• Charge the battery instrument until the amber-coloured indicator will light up.

• When starting up the instrument make sure that the AUTO POWER OFF function is

OFF, in this case the indicator will be lit in green colour, and then keep it for approximately 10 to 14 hours.

Use the equipment in normal way, reason why after one to three whole cycles of charge/discharge, depending on the time and temperature of inactivity, the battery will have been reconditioned.

3.2 Installation and start-up.

The PROLITE-60 has been designed for use as portable equipment.

A fully charged battery can power the equipment for more than three hours. When the low battery indicator appears on the display ( ), the battery must be recharged.

When a fully discharged battery is installed, it is possible that, due to residual charges, the PROLITE-60 may start up. In this case, the instrument will automatically disconnect before the low battery indicator appears on the display.

In order to start up the equipment, verify that the service switch [21] is at I position

(see figure 2 ”View of side panel and connectors”) and press the turn on key [1] on the frontal panel.

After the instrument boot process, this one will remain with the last measurement configuration memorised.

The screensaver will automatically get started after 5 minutes without pressing any key.

The service switch [21] allows for example to leave the equipment under battery minimum consumption status, this is very advisable when a long period of inactivity is expected.

Before turning off the instrument using this switch is advisable to shut down it previously by means of the power off key [1] on frontal panel.

saver

After 5 minutes of non-operation from the front panel the screen becomes black with the PROMAX logo moving around.

The scanning process was stopped until a new operation is activated through the front panel.

Page 10 09/2007

USER’S MANUAL. PROLITE-60

4 OPERATING INSTRUCTIONS

4.1 Description of the controls and elements

Front panel

Figure 1.- Front panel.

[1]

On / Off key.

[2]

Selects marker MKR1 or the relative marker

MKR as active marker (tunable) and exchanges between them.

[3]

Defines the wavelength range represented in the horizontal scale between (10,

20, 50, 100, 200 and 400 nm).

[4]

Selects the acquisition mode used to visualise traces on screen: Signal, Max

Hold, Min Hold and Average.

USER’S MANUAL. PROLITE-60

[5]

Defines the amplitude of the selectionable vertical scale between 10 and 2 dB/div.

[6]

Access to the measurement function and configuration equipment menu.

[9] Colour TFT graphic monitor.

[10] Battery charge indicator.

[11] External power supply indicator.

[12] Optical output (optional).

Maximum input level 10 dBm.

Side panel

Page 12

Figure 2.- View of side panel and connectors.

09/2007

USER’S MANUAL. PROLITE-60

[20] External line power supply connection.

[22] Fan.

[23] Loudspeaker.

[24] RS232C serial port. DB9 male connector.

[25] Parallel port. DB25 female connector.

[26] Ethernet interface connector. RJ45

4.2 Operating basic instructions

The PROLITE-60 offers five operation controls:

In order to accede to each operation mode, press the corresponding key. An operation mode remains activated while the luminous indicator adjacent to the mode selection key lit in green colour.

4.2.1 MARKER control:

This control is activated when pressing MARKER [2] key, the field MKR1 appears in red colour on the screen, composed by the wavelength measurement (λ) and the power level (Power) corresponding to the MKR1 mark position

By means of turning the rotary selector [8] is possible to place the mark throughout the represented spectrum on the desired wavelength. Also the marker can be positioned using the alphanumeric keypad [7], in order to enter a value directly within the available value range (from 1250 to 1650 nm) and later validate it by pressing the rotary selector [8].

When pressing afresh the MARKER key [2], the MKR incremental marker is activated indicating the wavelength differential values (λ) and power level (Power) with respect to the main marker (MKR1) position.

USER’S MANUAL. PROLITE-60

Figure 3.- MARKER mode.

When pressing the rotary selector [8] the active marker is located over a maximum of the visualised trace level.

When pressing

SPAN key (3) the SPAN field on the screen is highlighted in red colour.

The equipment allows to select between 6 ranges of sweeping (SPAN 10, 20, 50,

100, 200 and 400 nm). In order to select the desired range, press successively the

SPAN (3) key or introduce the numerical value by means of the keyboard [7] and later validate it by pressing the rotary selector [8].

When changing the SPAN, the visualized trace is located in the center of the screen over wavelength (λ) pointed by the MKR1.

Page 14

Figure 4.- SPAN 100 nm selection.

09/2007

USER’S MANUAL. PROLITE-60

In the display lower part appears a small box that includes the full spectrum representation (Full Span) in order to locate at any moment the zone of the spectrum corresponding to the main display that appears marked by a discontinuous white line box.

When the TRACE

key [4] is pressed, appears highlighted in red colour a screen field indicating the input signal measurement type that is being represented.

On the display right part are shown, by means of a numerical icons column, the traces available to operate:

Trace 0: It represents the input signal measuring trace, which is refreshed after each sweeping.

Traces 1 to 9: Traces previously saved.

The PROLITE-60

allows carrying out the following operations with traces:

1.- Saving traces:

In order to save the measurement (trace 0) and to assign it to a specific memory position, press the numerical key corresponding to the trace to be saved while holding the rotary selector [8] pressed.

For example, whether the rotary selector [8] and, later the key number 7 are simultaneously pressed. In the memory position corresponding to trace 7 the measurement value will be saved by the trace 0 at this moment.

2.- Viewing traces:

The active trace corresponds to the last one selected. It is shown on screen and it appears indicated with an arrow in the squared icons column on the screen right side. Over the active trace acts markers [2].

In order to activate the trace representation previously memorised press the numerical key that corresponds to the trace number to visualise.

The trace will appear on screen and the cursors will remain assigned to this trace. In order to deactivate it, press again the corresponding numerical key and the trace will be removed.

At any moment those previously memorised traces that have been selected will be visualised. Each trace appears drawn in the display with the same colour that the corresponding icon of the icons column that represent the traces in the display right part. Only those traces which icon appears highlighted in colour are shown on screen.

USER’S MANUAL. PROLITE-60

3.-

Relative measuring mode:

In order to view a trace in relative mode, that is a trace to represent the ratio between the input signal measurement (trace 0) and the memory trace (traces 1 from 9):

1.- Set on the trace that you wish to relativize (from 1 to 9).

2.- Press the [*] key.

It will appear on screen the squared icon the trace used to relativize the input signal.

*

witch colour corresponding to

In order to exit from this mode, press the [*] key.

4.-

Measurement type selection (trace 0):

When pressing in a sequential way the TRACE [4] key is possible to select the input signal acquisition type:

Signal

Max hold D Signal maximums memorisation, appears the “}“ symbol in the trace identifier icon.

Min Hold D Signal minimums memorisation, appears the “~“ symbol in the trace identifier icon.

Average

D

Average of signal values. It appears the symbol (µ) in the trace identifier icon.

5.-Picture capture:

When a double click is done by the rotary selector [8], the

PROLITE-60 saves an full screen image in (JPEG) format.

This picture is registered by means of a numerical value and could be recalled through the

Web Server

using a PC connected to the local network.

Page 16

Figure 5.- TRACE control.

09/2007

USER’S MANUAL. PROLITE-60

The AMPLITUDE [5] key allows to access to the instrument vertical sensitivity selection mode.

The value selection (from 10 to 2 dB) is carry out by pressing the AMPLITUDE [5] key or by pressing the rotary selector [8].

When 10 dB/div has been selected, by turning the rotary selector [8] allows to move the horizontal cursors that limit the spectrum area to visualise after setting 2 dB/div. Whether 2/div has been selected by turning the rotary selector [8] it selects the desired level range.

Figure 6.- 10 dB/div AMPLITUDE selection.

The horizontal guide-lines only appear when the AMPLITUDE mode is selected.

USER’S MANUAL. PROLITE-60

Page 18 09/2007

USER’S MANUAL. PROLITE-60

5 FUNCTIONS MODE (CONFIGURATION MENU):

5.1 Description

Press the FUNCTIONS [6] key in order to access to the PROLITE-60 functions menu, where the configuration functions for optical analyser basic parameters are included:

Figure 7.- FUNCTIONS. Main menu.

Settings menu:

Captures configuration for traces and images, reference line configuration and other parameters as language, hour/date, connection to local network, sound, automatic power off mode and

Web Server password settings.

Upgrade menu: Allows manual updating (via port series or ethernet connection), and automatic updating (via ethernet connection).

About window: Information about the equipment serial number, software version.

As well as the following measurement functions for specific applications:

DWDM MEASURE: It allows carrying out spectral analysis of optical systems with dense and coarse wavelength division multiplexing (DWDM and

CWDM).

OA MEASURE: Response verification in wavelength (λ) for OA (optical amplifiers).

USER’S MANUAL. PROLITE-60

Figure 8.- FUNCTIONS. Example of “OA MEASURE” function application.

5.2 Equipment configuration functions

The functions that are used to configure the operation parameters in the optical spectrum analyser

PROLITE-60, appear represented by means of icons on the first row of the window that is showed when pressing

FUNCTIONS key [6]. Turn the rotary selector [8] until placing the selection cursor on the icon of the function desired and press the rotary selector [8] to activate it.

Page 20

Figure 9.- FUNCTIONS. Settings menu.

09/2007

USER’S MANUAL. PROLITE-60

Turn and press the rotary selector [8] to select the option desired:

Configure Traces: Selects the trace to edit (from 1 to 9), it allows to delete a trace selected and reports about the registration time.

Configure Images: Selects the image to edit (from 1 to 19), it allows to delete a trace selected and reports about the registration time.

Configure Ref. Line: Defines the level of the reference line between —70 and 10 dBm in steps of 1 dB. It allows to activate or to deactivate the reference line representation.

Global Adjustments: It activates the equipment global adjustments menu.

Figure 10.- Global Adjustments menu (SETTINGS Menu).

Turn and press the rotary selector [8] to select the desired option:

Change Language:

Selects the language.

Configure Date/Time:

Shows and allows to modify by means of the numeric keypad the system hour and date.

Network adjustments: It allows to enter a valid IP address for the equipment, the netmask, the gateway address, as well as the proxy server address. Also the server IP dynamic address allocation (DHCP) can be activated.

Configure Sound:

Activates or deactivates the loudspeaker and adjust the level of sound.

Auto-Power OFF:

Remote Password:

It sets the shut down mode as Manual or Automatic, in the case of selecting Auto-Power OFF the time-out can be specified between 1and 240 minutes.

Restores the default value for the remote mode access password.

USER’S MANUAL. PROLITE-60

Figure 11.- UPGRADE Menu.

Turn and press the rotary selector [8] to select the desired option:

Manual Upgrade: It activates the process of automatic update through port series

(RS-232C) [24] or Ethernet network connection [26].

Automatic Upgrade: It activates the process of automatic update through ethernet network connection [26].

NOTE

In order to activate the automatic update process, previously must be configured suitably the network parameters and later to select: FUNCTIONS

Æ UPGRADE Æ

AUTOMATIC.

The PROLITE-60

is connected to the PROMAX WEB SITE and looks for the last version of software available.

In order to carry out a manual update, previously the versión file of corresponding software is due to load in the equipment, following the steps that are described next:

In case of using RS-232C port:

1. Connect a cable series between the PC and the PROLITE-60.

2. Execute in the PC a terminal emulator (e.g.: Hyperterminal, TeraTerm, etc..) and set the connexion to 19200 bauds, 8 bits, without parity and 1 stop bit.

3. Press ENTER, when it asks for the user name (default login) enter: serial

4. Send from the emulator the corresponding file of extension: .asc and press

Ctrl.+D.

Page 22 09/2007

USER’S MANUAL. PROLITE-60

In case of using the Ethernet connexion:

1. Set the network parameters suitably.

2. Accede to the Web server of the PROLITE-60 and select the Upgrade option.

3. Select the Update Firmware (manual) option.

4. Look for the new version file with extension: .asc in the PC.

Now, the manual update of the PROLITE-60 can be activated (Select FUNCTIONS - >

UPGRADE - > MANUAL).

Figure 12.- About.

Offers information about the equipment serial number, software version.

5.3 Equipment measurement functions

The optical spectrum analyser PROLITE-60 offers several measurement functions specially designed for specific applications which appear represented by means of icons on the second row of the window that is showed when pressing

FUNCTIONS [6] key. Turn the rotary selector [8] until locating the cursor over the icon of the desired function and finally press the rotary selector [8] to activate it.

5.3.1 LED MEASURE function

USER’S MANUAL. PROLITE-60

Figure 13.- LED source measurement.

Measurement parameters

Peak lambda Wavelength at which the peak of the LED spectrum occurs.

Mean Lambda

) Represents the center of mass for the trace points.

BW

Power

Bandwidth measured at 3 dB (half-power).

Result of energy integration over the wavelength range represented.

Peak Amplitude

Power level at the peak LED source.

Sigma (σ) LED spectral width equivalent value for a Gaussian distribution based on the previously defined λ

.

FWHM (Full Width at Half Maximum) describes the spectral width for LED half-power (-3dB) points, assuming a continuous, Gaussian power distribution based on previously defined λ

and σ.

File Access to the data file menu

Page 24 09/2007

USER’S MANUAL. PROLITE-60

Figure 14.- Data file menu.

Options

Save Values

Manage Files

Select

Delete

Load

Close Menu

Exit

Æ

Æ

Æ

Æ

Æ

Æ

Æ

Saves in a file the registered measurement parameters corresponding to the visualised trace.

Shows the data file list saved in memory.

Selects a data file containing the measurement parameters previously described.

It allows deleting a data file.

Load a data file.

Quits data file menu.

Quits measurement function.

5.3.2 DWDM MEASURE function

USER’S MANUAL. PROLITE-60

Figure 15.- WDM source measurements

Measurement parameters

For each WDM (Wavelength Division Multiplexing) carrier:

λ

Corresponds to the wavelength where is located (nm).

PWR Power level (dBm).

SNR Measurement of the optical signal-noise ratio (SNR).

For all carriers:

Min. Carrier number with a minimum measured level.

Max.

Tilt

Carrier number with a maximum measured level.

Calculation of the slope between carriers detected and according to the linear quadratic minimum function. (dB/nm)

Peak to peak

Peak to peak deviation, defined as difference between maximum and minimum carrier power (dB).

SETUP Menu Access to measurement parameters configuration menu.

Page 26 09/2007

USER’S MANUAL. PROLITE-60

Figure 16.- Measurement parameters configuration menu.

Options

Start Lambda (nm)

Æ

Sets the start wavelength for the scan.

Stop Lambda (nm)

Æ

Sets the stop wavelength for the scan.

Peak Excursion (dB) Æ Sets the peak excursion value. This is the amount of amplitude the trace must rise and fall to considered a peak. Lower values lead to more signals being discerned, but if the peak excursion is set too low, peaks in the noise floor may be discerned as signals.

Peak Threshold (dBm)Æ Sets the peak threshold value. Power levels below this threshold are not considered for peak search.

Noise Level (nm)

Close Menu

Æ

Selects the offset value to measure the noise floor. This value is used in the OSNR calculation.

Æ

Quits measurement parameters configuration menu

File

Æ

Data file menu access.

Options

Save Values

Manage Files

Select

Delete

Load

Close Menu

Æ

Saves in a file the registered measurement parameters corresponding to the visualised trace.

Æ

Shows the data file list saved in memory.

Æ Selects a data file containing the measurement parameters previously described.

Æ

It allows deleting a data file.

Æ

Load a data file.

Æ

Quits file management menu.

USER’S MANUAL. PROLITE-60

Scroll

Æ

It allows to move the visualization window of the WDM carrier parameters measurement data until appearing the

12 saved carriers.

Æ

Quits measurement function. Exit

5.3.3 DFB MEASURE function (Distributed Feedback)

Figure 17.- DFB source measurements.

Measurement parameters

Peak Wavelength Is the wavelength at which peak amplitude occurs.

Peak Amplitude Is the power level of the DFB‘s main spectral component.

BW Bandwidth of the main spectral component for the DFB source. Due to the narrow line width of most DFB sources, the result of this measurement for an unmodulated laser is limited by the resolution bandwidth of the optical spectrum analyser.

SMSR (Side Mode Suppression Ratio) is the amplitude ratio of the main spectral component and the largest side mode (not necessarily the first side mode) within the current trace.

Mode Off

(Mode Offset) wavelength separation between the main spectral component and the next highest mode within the current trace span. Negative values indicate the next highest mode lies to the left of the main mode and positive values indicate the next highest mode lies to the right of the main mode.

Page 28 09/2007

USER’S MANUAL. PROLITE-60

Center Off

Stop Band

(Center Offset) Indicates how well the main mode is centered in the stop band. This value is the difference between the wavelength of the main spectral component and the mean of the upper and lower stop band component wavelengths.

Is the wavelength spacing between the upper and lower side modes adjacent to the main mode.

Data file menu access. File

Options

Save Values

Manage Files

Select

Delete

Load

Close Menu

Exit

Æ

Saves in a file the registered measurement parameters corresponding to the visualised trace.

Æ

Shows the data file list saved in memory.

Æ Selects a data file containing the measurement parameters previously described.

Æ

It allows deleting a data file.

Æ

Load a data file.

Æ

Quits data file menu.

Æ

Quits measurement function.

5.3.4 FP MEASURE function (Fabry-Perot)

Figure 18.- FP sources measurement.

USER’S MANUAL. PROLITE-60

Measurement parameters

Mean Lambda

) Represents the center of mass for the trace points.

Peak lambda Wavelength of the FP source peak spectral component.

Mode Spacing Is the average wavelength spacing between the individual spectral components of the FP source.

FWHM (Full Width at Half Maximum) describes the spectral width for the

FP source half-power (-3dB) points, assuming a continuous,

Gaussian power distribution based on defined λ

and σ.

Power Result of energy integration over the wavelength range represented.

Peak Amplitude

Power level for the FP source peak spectral component. distribution based on the previously defined λ

.

Data file menu access. File

Options

Save Values

Manage Files

Select

Delete

Load

Close Menu

Exit

Æ

Saves in a file the registered measurement parameters

corresponding to the visualised trace.

Æ

Shows the data file list saved in memory.

Æ Selects a data file containing the measurement parameters previously described.

Æ

It allows deleting a data file.

Æ

Load a data file.

Æ

Quits data file menu.

Æ

Quits measurement function.

Page 30 09/2007

USER’S MANUAL. PROLITE-60

5.3.5 OA MEASURE function (Optical Amplifiers)

Figure 19.- Optical amplifiers measurements.

MEASUREMENT PROCEDURE

1.- Connect the input source to the optical spectrum analyser (OSA) input and press

Start.

The spectral response of the optical source is recorded appearing represented in blue colour.

2- Connect the amplifier output to the optical spectrum analyser (OSA) input and press

Start.

The spectral response of the optical amplifier is represented in green colour that appears superposed with the previous one for its comparison.

Figure 20.- Measurement parameters configuration menu.

USER’S MANUAL. PROLITE-60

Measurement parameters

For each one WDM carrier (Wavelength Division Multiplexing):

λ

Wavelength where is it located (nm)

PWR

SNR

GAIN

Power level (dBm).

Optical signal-noise ratio measurement (SNR).

Difference at each measured

λ between input and output.

SETUP Menu Access to measurement parameters configuration menu.

Options

Start Lambda (nm)

Æ

Sets the start wavelength for the scan.

Stop Lambda (nm)

Æ

Sets the stop wavelength for the scan.

Peak Excursion (dB)

Æ

Sets the peak excursion value. This is the amount of amplitude that trace must raise and fall to be considered as a peak. Lower values lead to more signals being discerned, but if the peak excursion is set too low, peaks in the noise floor may be discerned as signals.

Peak Threshold (dBm) Æ Sets the peak threshold value. Power levels below this threshold are not considered for peak search.

Noise Level (nm)

Close Menu

File

Æ

Selects the offset value to measure the noise floor. This value is used in the OSNR calculation.

Æ

Quits measurement parameters configuration menu

Æ

Data file menu access.

Options

Save Values

Manage Files

Exit

Select

Delete

Load

Close Menu

Æ

Saves in a file the registered measurement parameters corresponding to the visualised trace.

Æ

Shows the data file list saved in memory.

Æ Selects a data file containing the measurement parameters previously described.

Æ

It allows deleting a data file.

Æ

Load a data file.

Æ

Quits data file menu.

Æ

Quits measurement function.

Page 32 09/2007

USER’S MANUAL. PROLITE-60

6 WEB SERVER

It allows the remote access to the instrument functions through a local network, for it:

1) Set the local network parameters in the PROLITE-60 (IP, type of server, etc..).

3) Access to the instrument Web Server by means of a browser, connecting to the local network and acceding to the IP specified for this instrument.

Figure 21.- PROLITE-60. Web Server.

The PROLITE-60 Web Server offers the following functions:

Traces:

Images:

Offers measurement data from memorised traces.

Visualisation of previously captured traces.

Remote Mode: Visualisation operations for traces in remote mode.

Upgrade: Allows to recover the previous firmware updated files.

The option

Recover Traces

allows to recover the data relative to the memorised measurement traces, for each type of measurement: WDM, DFB, LED, FP or OA, is available up to nine trace memories, and when selecting this option will appear a listing of all the registered values.

USER’S MANUAL. PROLITE-60

Figure 22.- PROLITE-60 Web Server. Recovering data from memorised traces.

The PROLITE-60 can store in the memory up to nineteen pictures in JPEG format, corresponding to the traces visualised in the instrument display. When clicking on a memorised trace, this one is show in the Web Server monitor.

Figure 23.- PROLITE-60 Web Server. Recovering images from memorised traces.

Page 34 09/2007

USER’S MANUAL. PROLITE-60

6.3 REMOTE MODE function

It allows to accede to the PROLITE-60 remote control mode. The user can select traces and order operations from a remote computer. The access to the REMOTE control mode from the Web Server requires an ID (user name) and a password (by default: abcdefg).

Figure 24.- PROLITE-60 Web Server. Access to the remote control mode.

It allows to operate all the basic functions: MARKER, SPAN, TRACE,

AMPLITUDE and to introduce numerical values as when acting directly on the frontal panel controls.

In order to operate with traces select by means of the mouse each one to visualise with a click on the alphanumeric keypad that appears represented on the

PROLITE-60 webserver screen.

Click on the (PLAY) button in order the instrument carries out a measurement and refresh data on screen.

The

button allows to refresh data on screen. Threrefore, De esta forma, the information is updated when an equipment is being operated simultaneously by different users remotely.

Save trace: It allows to memorise the traces that appear on screen in the instrument memory.

USER’S MANUAL. PROLITE-60

Last Users: Listing of the last users who have acceded to the equipment and the commands executed.

Figure 25.- Web Server PROLITE-60. Remote mode traces control.

It allows to download in the equipment a file that contains the last version of the firmware. Therefore, a firmware manual update is possible from UPGRADE menu.

Figure 26.- PROLITE-60 Web Server. Recovering an updated firmware version.

Page 36 09/2007

USER’S MANUAL. PROLITE-60

7 MAINTENANCE

faults.

This part of the manual describes the maintenance procedures and the location of

7.1 Method of maintenance

The method of maintenance to be carried out by the user consists of cleaning the cover and changing the battery. All other operations should be carried out by authorised agents or by personnel qualified in the servicing of instruments.

7.1.1 Cleaning the cover.

CAUTION

Do not use scented hydrocarbons or chlorized solvents. Such products may attack the plastics used in the construction of the cover.

The cover should be cleaned by means of a light solution of detergent and water applied with a soft cloth. Dry thoroughly before using the system again.

CAUTION

To clean the contacts, use a dry cloth. Do not use a wet or damp cloth.

CAUTION

Do not use for the cleaning of the front panel and particularly the viewfinders, alcohol or its derivatives, these products can attack the mechanical properties of the materials and diminish their useful time of life.

7.2 Components which user can not replace

7.2.1 Not replaceable fuses by user

To be replaced by qualified personnel. Its position identifier and characteristics are:

F001: FUS 7 A T 125 V SMD

F002: FUS 7 A T 125 V SMD

USER’S MANUAL. PROLITE-60

Page 38 09/2007

USER’S MANUAL. PROLITE-60

APPENDIX A : QUICK REFERENCE GUIDE

How to operate with (MARKER)

Absolute marker MKR 1

1. Press [2] to activate MKR1 field. by turning the rotary selector [8].

3. Pressing the rotary selector [8] the MKR1 will go directly to the maximum value of the active trace, that corresponds to the selected trace to be visualised on screen

(positions from 0 to 9 in the squared icons right column).

Relative marker MKR

1. Press [2] again to activate ∆MKR. by turning the rotary selector [8].

3. Pressing the rotary selector [8] the ∆MKR will go directly to the maximum value of the active trace.

How to operate with (SPAN)

1. Press [3] to activate the Span field.

2. Set the numeric value by using the alphanumeric keypad [7]: (10, 20, 50, 100, 200,

400 nm).

3. Another way to select the required Span is by pressing the

Pressing this key consecutively the value changes cyclically too.

[3] key.

Whenever Span changes, the new Span will be centered at the MKR1 wavelength

(λ).

How to operate with (TRACES)

USER’S MANUAL. PROLITE-60

1. Press [4] to activate Trace field.

2. At the right side of the screen there is a column with 11 coloured small squares.

Each coloured square corresponds to one coloured trace.

(0) Square: Corresponds to the data trace (in green colour). This trace is always the measured input signal and it is updated after each scan.

Pressing the [4] key when Trace field is active (in red colour), it’s possible to select different types of measurement: SIGNAL -> MAX. HOLD -> MIN. HOLD -

> AVERAGE -> ...

The selected mode will be displayed into the measurement screen except for

SIGNAL mode (normal operation).

(1)-(9) Squares: Correspond to memorised traces. It is possible to copy the data trace (0) to anyone of this other traces (from 1 to 9).

The process is easy. Always with the Trace field active (in red colour), press the rotary selector [8] simultaneously with the numerical key [7]. For example, if you press the rotary selector [8] + key number (7), the trace (7) will take the same value that the data trace (0).

Anyone of the memorised trace can be displayed or removed on screen simply by pressing the corresponding numeric key.

(*) Square: Corresponds to relative trace which allow memorise the difference between the data trace (0) and the active trace. In order to visualize this trace, select any trace form (1) to (9) and press the (

*

) key.

How to operate with (AMPLITUDE)

1. Press [5] to active Scale field.

2. Select 10 dB/div or 2 dB/div using the alphanumeric keypad [7] or with the same

[5] key.

3. In 10 dB/div mode, will appear two horizontal dotted-lines indicating the view screen area at 2 dB/div.

Page 40 09/2007

USER’S MANUAL. PROLITE-60

How to save traces screen as a JPEG file

1. Press twice the rotary selector [8] while Trace mode remains activated.

2. A JPEG file will be created containing the full screen information.

3. It is possible to access to this picture through the

WEB SERVER

.

How to access to the

WEB SERVER

1. First it is necessary connect the PROLITE-60 to an ethernet network or direct to a computer using the suitable cable.

2. Configure the network parameters (IP, PROXY SERVER, etc.,.) by pressing

FUNCTION -> SETTING -> GLOBAL ADJUSTMENTS -> NETWORK ADJ.

4. Access to the

WEB SERVER

from the computer using an Internet browser (IE,

FireFox, Netscape...).

MANUEL D’UTILISATION. PROLITE-60

S O M M A I R E

1 GÉNÉRALITÉS............................................................................................................. 1

1.1

1.2

Description .......................................................................................................... 1

Spécifications .................................................................................................... 2

2 PRESCRIPTIONS DE SÉCURITÉ ............................................................................... 5

3

2.1

Générales............................................................................................................ 5

2.2

Exemples de Catégories de Surtension .............................................................. 7

2.3

Précautions spécifiques pour l’option OP-A: Source à bande large ................... 7

INSTALLATION ............................................................................................................ 9

3.1

Alimentation......................................................................................................... 9

3.1.1

Charge de la batterie .................................................................................... 9

3.1.2

Recommandations pour l’utilisation de la batterie ...................................... 10

3.2

Installation et mise en service. .......................................................................... 10

3.3

Sauve-écran ...................................................................................................... 10

4 MODE D’EMPLOI ....................................................................................................... 11

4.1

Description des commandes et des éléments................................................... 11

4.2

Instructions d’opération ..................................................................................... 13

4.2.1

Contrôle du MARKER: ................................................................................ 13

4.2.2

Contrôle du SPAN:...................................................................................... 14

Contrôle de TRACE: ................................................................................... 15 4.2.3

4.2.4

Contrôle d’AMPLITUDE: ............................................................................. 17

5 Mode FUNCTIONS (CONFIGURATION MENU):....................................................... 19

5.1

Description ........................................................................................................ 19

5.2

Fonctions de configuration de l’appareil............................................................ 20

5.2.1

Menu SETTINGS ........................................................................................ 20

5.2.2

Menu UPGRADE ........................................................................................ 22

5.2.3

Fenêtre ABOUT .......................................................................................... 23

5.3

Fonctions de mesure de l’appareil .................................................................... 23

5.3.1

5.3.2

Fonction LED MEASURE ........................................................................... 24

Fonction DWDM MEASURE....................................................................... 26

5.3.3

Fonction DFB MEASURE (Distributed Feedback)...................................... 28

5.3.4

Fonction FP MEASURE (Fabry-Perot) ....................................................... 30

5.3.5

Fonction OA MEASURE (Optical Amplifiers).............................................. 31

6 TÉLÉCONTRÔLE

(

WEB SERVER

)

........................................................................... 35

6.1

Fonction TRACES ............................................................................................. 35

6.2

Fonction IMAGES.............................................................................................. 36

6.3

Mode REMOTE ................................................................................................. 37

6.4

Fonction UPGRADE.......................................................................................... 38

7 ENTRETIEN................................................................................................................ 39

7.1

Méthode de maintenance.................................................................................. 39

7.1.1

Nettoyage du boîtier.................................................................................... 39

7.2

Les composants non remplaçables par l’utilisateur........................................... 39

7.2.1

Fusibles non remplaçables par l’utilisateur ................................................. 39

APPÉNDIX A : GUIDE RAPIDE D’UTILISATION .......................................................... 41

MANUEL D’UTILISATION. PROLITE-60

MANUEL D’UTILISATION. PROLITE-60

ANALYSEUR DE SPECTRE OPTIQUE

PROLITE-60

1 GÉNÉRALITÉS

1.1 Description

Le PROLITE-60 est un analyseur de spectre optique, portatif qui fonctionne à batteries. Il s'avère adéquat pour de multiples applications, entre lesquelles on inclut la vérification de systèmes de télécommunication WDM (Wavelength Division

Multiplexing) / CWDM (Coarse Wavelength Division Multiplexing), en outre au moyen de plusieurs options et d'accessoires disponibles peut aussi être utilisé dans des applications de reflectometrie, analyse de matériels, capteurs de fibre optique, vérification de dispositifs photoniques comme des filtres, atténuateurs, accoupleurs, isolateurs et d'autres composants optiques.

L'instrument incorpore des fonctions spécifiques qui lui permettent de caractériser la réponse de différents systèmes de transmission optique, comme par exemple les mesures LEDs, DWDM, DFB, FP, d'OA, etc.. Toutes ces mesures sont configurables à travers les paramètres accessibles pour l'utilisateur au moyen de menus graphiques sur un écran d'utilisation intuitive.

Dans le mode d'analyse du spectre optique il dispose de deux curseurs mobiles qui agissent comme marqueurs le long de la marge d'exploration des longueurs d'onde.

Le SPAN est variable de 10 nm à 400 nm pour fournir la visualisation du spectre dans l'échelle horizontale, aussi sur l'échelle verticale on peut établir des divisions de

10 dB ou 2 dB pour obtenir une plus grande résolution dans les mesures.

Il incorpore dix positions de mémoire pour stocker les traces enregistrées préalablement et travailler avec elles postérieurement. Les mesures acquises peuvent

être révisées, être transférées à un PC ou être imprimées à tout moment. Permet aussi l'accès à distance aux données enregistrées à travers d’un réseau TCP/IP (Web

Server).

Le PROLITE-60 répond aux nécessités de mesures sélectives en longueur d'onde, des opérateurs de télécommunications qui transmettent simultanément de multiples longueurs d'onde à travers d’une même fibre optique, afin de rentabiliser les réseaux existants.

Au cours de la conception du PROLITE-60, il a été prêté une attention spéciale à la réalisation d’un instrument pratique et précis, mais en même temps facile à utiliser.

Un clavier alphanumérique alphanumérique simple avec un sélecteur rotatif qui permet l’accès direct aux différentes fonctions de mesure.

La présence de toutes ces fonctions dans un instrument de dimensions réduites et bas poids, avec une conception ergonomique et robuste, fait du PROLITE-60 un outil de travail sur terrain incomparable.

MANUEL D’UTILISATION. PROLITE-60

1.2 Spécifications

LONGUEUR D'ONDE

Marge de longueurs d'onde

Span

Résolution optique

Précision

De 10 nm à 400 nm.

0,15 nm.

± 0,5 nm.

± 0,2 nm.

Stabilité

PUISSANCE

1

Marge dynamique

Précision

Planéité

Stabilité

Relation signal bruit optique (OSNR)

Sélectif à 1550 nm

De - 60 dBm à 10 dBm.

± 1 dB.

± 0,50 dB.

± 0,2 nm

à 25 GHz (± 0,2 nm)

à 50 GHz (± 0,4 nm)

à 100 GHz (± 0,8 nm)

De 1250 à 1650 nm.

18 dB (min.)

25 dB (min.)

30 dB (min.)

POLARISATION

CYCLE DE BALAYAGE

CONNECTEURS

Optique standard

PRÉSENTATION MONITEUR

Moniteur

INTERFACE DE COMMUNICATIONS

Port série

FC/PC

TFT couleur de 6,4”

RS-232

ALIMENTATION

Tension d'alimentation

Indicateur de batterie faible

Autonomie

Arrêt automatique

Charge de batterie

Consommation

100-240 V AC

Indication graphique à l'afficheur :

Environ 3 heures.

Déconnexion avec temporisation configurable

(1 à 240 min.).

Par alimentateur rapide interne.

36 W.

1

Valeurs valides pour fibres optiques (9/125 µm) et connecteur FC/PC.

Page 2 09/2007

MANUEL D’UTILISATION. PROLITE-60

CONDITIONS D’ENVIRONNEMENT

Les conditions d'environnement dans lesquelles l'appareil peut opérer, tout en maintenant les caractéristiques, sont les suivantes :

Altitude Jusqu’à 2000 mètres.

Marge de températures De

Humidité relative maximale 80 % (Jusqu’à 31 °C), diminution linéaire jusqu'au 50% à 40 °C.

CARACTÉRISTIQUES MÉCANIQUES

Dimensions L. 294 x H. 126 x P. 274 mm.

ACCESSOIRES INCLUS

CA-005

0 FD0453

Câble de secteur

Couverture de transport.

OPTIONS

A Source à bande large.

Source de lumière SLED de 1566 nm (Consulter possibles alternatives).

Puissance

BW

3dB

- 8 dBm

73

72

71

70

Connecteur optique FC - PC

Connecteur optique SC - PC

Connecteur optique FC - E2000

Connecteur optique FC - ST

(Consulter la disponibilité de connecteurs APC)

MANUEL D’UTILISATION. PROLITE-60

Page 4 09/2007

MANUEL D’UTILISATION. PROLITE-60

*

*

2 PRESCRIPTIONS DE SÉCURITÉ

2.1 Générales

*

Il s’agit d’un appareil de type I. Pour des raisons de sécurité, il doit être branché aux lignes du réseau avec la prise de terre correspondante.

*

Cet appareil peut être utilisé sur des installations de la Catégorie de Surtension

II et Dégré de Pollution 2.

*

Les accessoires suivants ne doivent être utilisés que pour les appareils spécifiés afin de préserver la sécurité :

Câble de secteur

*

Toujours avoir compte des marges spécifiées aussi pour l'alimentation que pour effectuer une mesure.

*

Observer toujours les conditions ambiantes maximales spécifiées pour cet appareil.

*

L'opérateur n'est autorisé à intervenir que pour :

Tout changement dans l'appareil devra être exclusivement effectué par du personnel spécialisé.

*

Le négatif et le blindage des connecteurs d’Entrée / Sortie se trouvent au potentiel de terre.

Ne pas obstruer le système de ventilation.

Suivez strictement les recommandations de nettoyage décrites au paragraphe

Entretien.

*

Symboles concernant la sécurité :

ALTERNATIF ET CONTINU

MANUEL D’UTILISATION. PROLITE-60

TERMINAL DE TERRE

TERMINAL DE PROTECTION

TERMINAL A LA CARCASSE

EQUIPOTENTIALITE

MARCHE

ÂRRET

(Protection CLASSE II)

PRÉCAUTION

(Risque de secousse électrique)

PRÉCAUTION VOIR MANUEL

FUSIBLE

Page 6 09/2007

MANUEL D’UTILISATION. PROLITE-60

2.2 Exemples de Catégories de Surtension

Cat. I

Cat. II

Cat. III

Installations de basse tension séparées du secteur.

Installations domestiques mobiles.

Installations domestiques fixes.

2.3 Précautions spécifiques pour l’option OP-A: Source à bande large

PRÉCAUTION

Il est déconseillé de regarder directement le faisceau.

L’utilisation de dispositifs autres que ceux qui sont spécifiés dans ce manuel ainsi que la manipulation interne de l’instrument peuvent être la cause de radiations dangereuses.

MANUEL D’UTILISATION. PROLITE-60

Page 8 09/2007

MANUEL D’UTILISATION. PROLITE-60

3 INSTALLATION

3.1 Alimentation

Le PROLITE-60 est un instrument portatif alimenté par une batterie NiMh, intégrée. Avant de prendre une mesure quelconque, s'assurer que la batterie est chargée à plein.

3.1.1 Charge de la batterie

L’appareil dispose d’un adaptateur de secteur pour alimenter l’équipe ou charger la batterie.

Il y a deux situations différentes dans la charge de la batterie :

1) Avec l'appareil arrêté, sur avoir connecté le câble de secteur est reprise un cycle de charge rapide, dont la durée dépendra de la condition de la batterie. Pour une batterie déchargée le mentionné temps sera de 3,5 h. approximativement.

L’indicateur de charge du panneau frontal, restera illuminé en couleur ambre pendant cette période.

À la fin de celui-ci, l’indicateur passe au vert, qui est la marque du chargement de maintenance.

2) Avec l’appareil en marche en reliant l’adaptateur celui-ci alimente l’appareil et fournit une charge de maintien en restant l’indicateur de charge illuminé en coleur vert.

ATTENTION

Chaque fois que se pour l’appareil ou on relie l'alimentation extérieure de l'appareil on recommence un processus de charge.

C’est pour cela recommandée de décharger la batterie employant l’appareil sans alimentation extérieur pour réaliser un processus achevé de charge / décharge.

ATTENTION

Le système de charge du PROLITE-60 incorpore un système de sécurité qui ne permet pas la charge à partir d’une certaine limite de température, amorçant la charge en mode maintenance, avec indication intermittente ambre/vert jusqu’à ce que la température diminue à la valeur requise.

PRÉCAUTION

Avant d'utiliser l’appareil, vérifier qu’est conforme à la tension de secteur.

MANUEL D’UTILISATION. PROLITE-60

3.1.2 Recommandations pour l’utilisation de la batterie

En prévoyant une longue période d'inactivité de l'appareil il est recommandable de le stocker avec la batterie déchargée.

En mettant l'appareil en service après une longue période d'inactivité il faut suivre ces recommandations:

• Mettre à charger l’appareil jusqu’à ce que l’indicateur lumineux de charge en couleur ambre soit illuminé.

• Mettre en marche l'appareil, en s’assurant que la fonction AUTO POWER

OFF est bien en OFF, l’indicateur restera allumé en vert, maintenir cette situation pendant 10 à 14 heures.

Utiliser l'appareil en mode normal, alors après d’un à trois cycles complets de charge/décharge, selon le temps et la température d'inactivité, la batterie aura été reconditionnée.

3.2 Installation et mise en service.

Le PROLITE-60 est un appareil conçu pour être utilisé tenu à la main.

La batterie à pleine charge peut alimenter l'appareil plus de trois heures de suite.

La batterie devra être rechargée aussitôt que l'indicateur ( ) est affiché.

L'installation d'une batterie à plat peut réussir à mettre en service le PROLITE-60 par des charges résiduelles. Même dans ce cas, la durée de l'alimentation sera courte au point de ne pas afficher l'indicateur de batterie faible.

Pour mettre en marche l'appareil, vérifier que l'interrupteur de service [21] se trouve dans la position I (voir figure 2. Vue du panneau latéral et connecteurs) et pousser la touche de mise en marche [1] dans le panneau frontal.

Passé le processus d'initialisation interne de l’appareil, celui-ci restera avec la dernière configuration de mesure mémorisée.

Le protecteur d'écran est automatiquement activé passés 5 minutes sans agir sur aucun contrôle.

L’interrupteur de service [21] permet par exemple de laisser l’équipement en situation de consommation minimale par la batterie, très nécessaire devant la prévision d’une longue période d’inactivité.

Avant d’arrêter l’appareil au moyen de cet interrupteur il faut avoir arrêté préalablement par la touche de mise en marche [1] du panneau avant.

3.3 Sauve-écran

Après cinq minutes sans activer aucune opération depuis le panneau frontal l'écran apparaît noir avec le logo de PROMAX en mouvement.

Le processus de balayage s'arrête jusqu'à ce qu'on active une nouvelle opération depuis le panneau frontal.

Page 10 09/2007

MANUEL D’UTILISATION. PROLITE-60

4 MODE D’EMPLOI

4.1 Description des commandes et des éléments

Panneau avant

Figure 1.- Vue avant.

[1]

Touche de mise en marche et déconnexion de l’appareil.

[2]

Sélectionne le marqueur MKR1 ou le marqueur relative ∆MKR comme marqueur actif (pouvant être syntonisé) et il échange entre eux.

[3]

Définit la marge de longueurs d'onde représentée dans l'échelle horizontale entre

(10, 20, 50, 100, 200 et 400 nm).

[4]

Sélectionne le mode de visualisation de traces sur l’écran entre: Signal, Max

Hold, Min Hold et Average.

MANUEL D’UTILISATION. PROLITE-60

[5]

Définit l'ampleur de l'échelle verticale sélectionnable entre 10 et 2 dB/div.

[6]

Accès au menu de fonctions de mesure et configuration de l'équipement.

[7] Clavier

[9] Moniteur graphique TFT en couleur.

[10] Indicateur de charge de la batterie.

[11] Indicateur d'alimentation externe.

[12] Sortie optique (facultatif).

Niveau d'entrée maximal 10 dBm.

Panneau latéral

Page 12

Figure 2.-

Vu du panneau latéral et connecteurs.

09/2007

MANUEL D’UTILISATION. PROLITE-60

[20] Connexion d'alimentation de secteur externe.

[21] Interrupteur de service.

[22] Ventilateur.

[23] Haut-parleur.

[24] Port série RS232C. Connecteur DB9 mâle.

[25] Port parallèle. Connecteur DB25 femelle.

[26] Connecteur d'interface ethernet. RJ45

Le PROLITE-60 présente cinq contrôles de fonctionnement :

Pour accéder à chaque mode d'opération il suffit de pousser la touche correspondante. Un mode d'opération reste activé quand l'indicateur lumineux adjacent

à la touche de sélection du mode est illuminé en couleur verte.

4.2.1 Contrôle du MARKER:

Ce contrôle est activé quand on pousse la touche MARKER [2], alors apparaît en couleur rouge le domaine MKR1 de l'écran, composé de la mesure de longueur d'onde

(λ) et le niveau de puissance (Power) correspondant à la position de la marque

MKR1.

Le tour du sélecteur rotatif [8] permet de placer cette marque le long du spectre représenté. On peut aussi placer directement le marqueur avec une valeur dans la marge de valeurs admises (1250 à 1650 nm) au moyen du clavier alphanumérique alphanumérique [7] et en poussant le sélecteur rotatif [8] pour le valider.

Si on pousse de nouveau la touche MARKER [2] on active le marqueur incrémental MKR qui indique les valeurs différentiels de longueur d'onde (λ) et niveau de puissance (Power) respecte la position de la marque principale (MKR1).

MANUEL D’UTILISATION. PROLITE-60

Figure 3.- Mode MARKER.

En poussant le sélecteur rotatif [8] la marque active est placée sur un maximum du niveau de la trace visualisée.

4.2.2 Contrôle du SPAN:

En poussant la touche

SPAN (3) on illumine en couleur rouge le domaine de l'écran indiqué comme

SPAN.

L'appareil permet de choisir entre 6 marges de balayage (SPAN 10, 20, 50, 100,

200 et 400 nm). Pour choisir la marge souhaitée, pousser successivement la touche

SPAN

(3) ou bien introduire la valeur numérique au moyen du clavier alphanumérique

[7] et le valider en poussant le sélecteur rotatif [8].

Quand on change le SPAN, la trace visualisée sera placée dans le centre de l'écran sur la longueur d'onde (λ) indiquée par le MKR1.

Page 14

Figure 4.- Sélection SPAN 100 nm.

09/2007

MANUEL D’UTILISATION. PROLITE-60

Dans la partie inférieure de l’écran apparaît un petit tableau avec la représentation du spectre complet (Full Span) afin de localiser à tout moment la zone du spectre correspondant à l’écran principal qui est marqué par un cadre blanc de lignes discontinues.

4.2.3 Contrôle de TRACE:

Quand on pousse la touche TRACE [4] il apparaît en couleur rouge le domaine de l'écran où on indique le type de trace qui est en train d’être représentée pour le signal d’entrée.

Dans la partie droite de l'écran on montre, au moyen d’une colonne d'icônes numériques, les traces disponibles pour opérer:

Trace 0: Il représente la trace de mesure du signal d'entrée, qui est rafraîchie à partir de chaque balayage.

Trace 1 à 9: Ils représentent les traces qui ont été précédemment mémorisées.

Le PROLITE-60 permet d'effectuer les opérations suivantes avec les traces:

1.- Mémorisation de traces:

Pour sauver la mesure (trace 0) et l'assigner à une position de mémoire, pousser la touche numérique correspondant à la trace qu'on souhaite mémoriser tandis qu'on maintient poussé le sélecteur rotatif [8].

Par exemple, si on pousse le sélecteur rotatif [8] et, ensuite, la touche nombre

7. Dans la position de mémoire correspondant à la trace 7 on gardera la valeur de la mesure représentée par la trace 0 dans ce moment.

2.- Visualisation de traces:

La trace active correspond à la dernière trace choisie. Elle est visualisée dans l'écran et est indiquée avec une flèche dans la colonne d'icônes carrées de la partie droite de l'écran. Sur la trace active agissent les marqueurs [2].

Pour activer la représentation d'une trace préalablement mémorisée pousser la touche numérique qui correspond au numéro de trace qu'on souhaite visualiser.

La trace apparaîtra dans l’écran et les curseurs resteront assignés à cette trace. Pour la désactiver, pousser de nouveau la touche numérique correspondante et la trace cessera d'être visualisée dans l'écran.

À tout moment on visualisera ces traces préalablement mémorisées qui ont

été choisies. Chaque trace est dessinée dans l'écran avec la même couleur que l'icône correspondante de la colonne d'icônes que représentent les traces à la partie droite de l'écran. On visualise les traces dont l'icône est soulignée en couleur.

MANUEL D’UTILISATION. PROLITE-60

3.-

Représentation de mesures relatives:

Pour visualiser une trace en mode relative, c'est-à-dire une trace qui représente la relation entre la mesure du signal d'entrée (trace 0) et la trace (de 1

à 9) qui a été choisie comme active :

1.- Activer la trace que vous souhaitez relativiser (1 à 9).

2.-Pousser la touche [*].

Apparaîtra l’icône

*

carré avec le coleur correspondant à la trace avec la quelle on a relativisé le signal d’entrée.

Pour sortir de ce mode il faut pousser la touche [*].

4.- Sélection du type de mesure (trace 0):

En poussant de manière séquentielle la touche TRACE [4] il est possible de choisir le type d'acquisition du signal d'entrée:

Signal

Max Hold D Mémorisation des maximums du signal, apparaît le symbole “}“ dans l'icône identificatrice de la trace.

“~“ dans l'icône identificatrice de la trace.

Average

D

Moyenne des valeurs du signal. Apparaît le symbole (µ) dans l'icône identificatrice de la trace.

5.- Sasie d’images:

Quand on fait un double clic sur le sélecteur rotatif [8], le PROLITE-60 garde une image en format (JPEG) de l'écran complet.

À cette image on l’assigne une valeur numérique et elle pourra être récupérée au moyen du

WEB SERVER

avec un PC relié au réseau local.

Page 16

Figure 5.- Contrôle de TRACE.

09/2007

MANUEL D’UTILISATION. PROLITE-60

4.2.4 Contrôle d’AMPLITUDE:

La touche

AMPLITUDE [5] permet d'entrer dans la sélection de la sensibilité verticale de l'instrument.

La sélection de 10 à 2 dB est effectuée en poussant la touche

AMPLITUDE [5] ou en poussant le sélecteur rotatif [8].

Quand on a choisi 10 dB/div, le tour du sélecteur rotatif [8] permet de déplacer les curseurs horizontaux qui limitent le secteur du spectre qui sera visualisé en passant à 2 dB/div. Si on a activé 2 dB/div, le tour du sélecteur rotatif [8] choisit le marge de niveaux souhaités.

Figure 6.-

Sélection AMPLITUDE 10 dB/div.

Les guides horizontaux seulement apparaissent à l’écuan quand on a choisi le mode AMPLITUDE.

MANUEL D’UTILISATION. PROLITE-60

Page 18 09/2007

MANUEL D’UTILISATION. PROLITE-60

5 Mode FUNCTIONS (CONFIGURATION MENU):

5.1 Description

En poussant la touche FUNCTIONS [6] on accède au menu des fonctions du

PROLITE-60, entre lesquelles on inclut les fonctions de configuration des paramètres de base pour l’opération de l'analyseur optique:

Figure 7.-

FUNCTIONS. Menu principal.

Menu Settings :

Configuration des traces et images saisies, configuration de la ligne de référence et paramètres comme langage, heure/date, connexion au réseau de données, son, arrêt automatique et change de la clé d'accès au Web Server.

Menu Upgrade : Mise à jour manuel (port série ou Ethernet), mise à jour automatique (Ethernet).

Fenêtre About : Information sur le numéro de série de l'appareil, la version du software.

Ainsi que les suivantes fonctions de mesure pour applications spécifiques :

LED MEASURE : Caractérisation des sources de lumière LED (diodes de sources de lumière).

DWDM MEASURE : Il permet d'effectuer une analyse spectrale de systèmes optiques avec multiplexation par division dense et non dense de la longueur d'onde (DWDM et CWDM).

DFB MEASURE : Caractérisation des sources DFB (laser de réalimentation distribuée).

FP MEASURE : Caractérisation des sources FP (laser Fabry-Perot).

OA MEASURE : Vérification de la réponse en longueur d’onde (λ) des amplificateurs optiques (OA).

MANUEL D’UTILISATION. PROLITE-60

Figure 8.-

FUNCTIONS. Exemple d’application de la fonction OA MEASURE.

5.2 Fonctions de configuration de l’appareil

Les fonctions qui sont utilisées pour configurer les paramètres d'opération de l'analyseur de spectre optique PROLITE-60, sont représentées au moyen d'icônes sur la première file de la fenêtre qui est montrée en poussant la touche FUNCTIONS [6].

Tourner le sélecteur rotatif [8] jusqu'à situer le curseur de sélection sur l'icône de la fonction souhaitée et pousser finalement le sélecteur rotatif [8] pour l'activer.

Page 20

Figure 9.- FUNCTIONS. Menu de settings.

09/2007

MANUEL D’UTILISATION. PROLITE-60

Tourner et pousser le sélecteur rotatif [8] pour choisir l'option souhaitée:

Configure Traces: Il choisit l'image à éditer (1 à 9), aussi permet d'éliminer l'image choisie et informe sur le moment de sa saisie.

Configure Images: Il choisit l'image à éditer (1 à 19), aussi permet d'éliminer l'image choisie et informe sur le moment de sa saisie.

Configure Ref. Line: Définit le niveau de la ligne de référence entre — 70 et 10 dBm dans sauts de 1 dB. Il permet d'activer ou de désactiver la représentation de la ligne de référence.

Global Adjustments : Il active le menu d’ajustements globaux de l’appareil.

Figure 10.- Menu Global Adjustments (Menu SETTINGS).

Tourner et pousser le sélecteur rotatif [8] pour choisir l'option souhaitée :

Change Language: Sélectionne la langue.

Configure Date/Time: Montre et permet de modifier au moyen du clavier alphanumérique l'heure et la date.

Network adjustments: Permet d'introduire la direction IP de l'appareil, le masque de réseau, l'adresse du gateway et l'adresse du serveur proxy. On peut aussi établir l'assignation dynamique d’adresses IP (DHCP) du serveur.

Configure Sound:

Auto-Power OFF:

Active ou désactive le haut-parleur et adapte le volume de son.

Il établit l’arrêt comme Manuel ou Automatique, dans le cas de choisir un arrêt Automatique on peut spécifier l'intervalle de temporisation entre 1 et 240 minutes.

Remote Password:

Rétablit au valeur par défaut la clé d'accès au mode de télécontrôle.

MANUEL D’UTILISATION. PROLITE-60

Figure 11.- UPGRADE Menu.

Tourner et pousser le sélecteur rotatif [8] pour choisir l'option souhaitée:

Manual Upgrade: Il active le processus manuel de mise à jour à travers le port série (RS-232C) [24] ou la connexion au réseau Ethernet [26].

Automatic Upgrade: Active le processus de mise à jour automatique à travers la connexion au réseau Ethernet [26].

REMARQUE

Pour activer la mise à jour automatique, on doit préalablement configurer adéquatement les paramètres du réseau et choisir: FUNCTIONS Æ UPGRADE Æ AUTOMATIC.

Le PROLITE-60 est relié au WEB SITE de PROMAX et cherche la dernière version de logiciel disponible.

Pour effectuer une mise à jour manuelle, on doit préalablement charger dans l'appareil les archives de la version de software correspondant, les pas qui sont décrits ensuite:

En utilisant le port RS-232C :

1. Relier un câble série entre le PC et le PROLITE-60.

2. Exécuter dans le PC un émulateur de terminal (p.e.: Hyperterminal,

TeraTerm, etc.,.) et configurer la connexion à 19200 bauds, 8 bits, sans parité et 1 bit de stop.

3. Pousser ENTER, quand on sollicite le nom d'utilisateur (default login) introduire : serial

4. Envoyer depuis l'émulateur l’archive correspondant d'extension : .asc et pousser Ctrl.+D.

Page 22 09/2007

MANUEL D’UTILISATION. PROLITE-60

En utilisant la connexion Ethernet :

1. Configurer adéquatement les paramètres du réseau.

2. Accéder au WEB Server du PROLITE-60 et choisir l'option Upgrade.

4. Chercher dans le PC l’archive de la nouvelle version d'extension: .asc

On peut maintenant déjà activer la mise à jour manuelle du PROLITE-60 (Choisir

FUNCTIONS - > UPGRADE - > MANUEL).

Figure 12.- About.

Offre information sur le numéro de série de l'appareil et la version du logiciel.

5.3 Fonctions de mesure de l’appareil

L'analyseur de spectre optique PROLITE-60 présente plusieurs fonctions de mesure conçues pour des applications spécifiques qui sont représentées au moyen d'icônes sur la seconde file de la fenêtre montrée quand on pousse la touche

FUNCTIONS [6]. Tourner le sélecteur rotatif [8] jusqu'à situer le curseur de sélection sur l'icône de la fonction souhaitée et pousser finalement le sélecteur rotatif [8] pour l'activer.

5.3.1 Fonction LED MEASURE

MANUEL D’UTILISATION. PROLITE-60

Figure 13.- Mesure de sources LED.

Paramètres de mesure

Peak lambda Longueur d'onde dans laquelle on trouve la valeur de pic du spectre de la source LED.

Mean Lambda

) C'est le centre de masses correspondant aux points de la trace.

BW Ampleur de bande mesuré à 3 dB.

Power Résultat de l'intégration de l'énergie dans la marge de longueurs d'onde représentée.

Peak Amplitude

Niveau de puissance pour le pic de la source LED.

Sigma (σ)

FWHM

Valeur équivalente de la largeur spectrale du LED pour une distribution Gaussienne, basée sur le λ

défini précédemment.

(Full Width at Half Maximum) définit le large spectral pour les points de puissance-moitié (diminution de -3dB) du LED, considérant une distribution Gaussienne basée sur le λ

et le σ definis précédemment.

File

Accès au menu des fichiers de données.

Page 24 09/2007

MANUEL D’UTILISATION. PROLITE-60

Options

Save Values

Figure 14.-

Menu des fichiers de données.

Manage Files

Select

Delete

Load

Close Menu

Exit

Æ

Æ

Æ

Æ

Æ

Æ

Æ

Garde dans un fichier les paramètres de mesure enregistrés pour la trace sur l'écran de l'analyseur de spectre optique.

Montre la liste de fichiers de donnés stockés dans la mémoire.

Sélectionne un fichier de données où on a stocké les paramètres de mesure décrits précédemment.

Permet d'effacer le fichier de données.

Charge les données d’un fichier.

Abandonne le menu d'archives de données.

Abandonne la fonction de mesure.

5.3.2 Fonction DWDM MEASURE

MANUEL D’UTILISATION. PROLITE-60

Figure 15.- Mesure de sources WDM.

Paramètres de mesure

Pour chaque porteuse WDM (Wavelength Division Multiplexing):

λ

Longueur d'onde où elle est située (nm)

PWR

SNR

Niveau de puissance (dBm).

Mesure de la relation signal-bruit optique

Pour toutes les porteuses:

(SNR).

Min. Numéro de la porteuse avec un niveau mesuré minimal.

Max.

Tilt

Peak to peak

SETUP Menu

Numéro de la porteuse avec un niveau mesuré minimal.

Calcul de la différence de niveau de la ligne qui est mieux ajustée aux porteuses détectées selon le critère des minimums carrés, ses unités sont dB/nm.

Déviation pic à pic, est définie comme la différence entre la puissance de la porteuse maximale et de la minimale (dB).

Accès au menu de configuration des paramètres de mesure.

Page 26 09/2007

MANUEL D’UTILISATION. PROLITE-60

Figure 16.-

Menu de configuration des paramètres de mesure

Options

Start Lambda (nm)

Æ

Établit la longueur d'onde initiale de balayage.

Stop Lambda (nm)

Æ

Établit la longueur d'onde finale de balayage.

Peak Excursion (dB) Æ Sélectionne la valeur de l'excursion de pic. C'est le parcours en ampleur que la trace doit décrire depuis le minimum jusqu'au maximum pour être considérée comme un pic. Les valeurs faibles permettent de détecter un plus grand nombre de signaux mais aussi peut être vues altérés par le niveau de bruit de fond.

Peak Threshold (dBm) Æ Sélectionne la valeur seuil de pic. Les niveaux de puissance sous ce seuil ne sont pas considérés pendant la recherche de pics.

Noise Level (nm)

Close Menu

File

Æ

Choisit la valeur de déplacement (offset) pour la mesure du bruit de fond. Cette valeur est utilisée pour le calcul du

SNR optique.

Æ

Il abandonne le menu de configuration des paramètres de mesure.

Æ

Accès au menu d'archives de données.

MANUEL D’UTILISATION. PROLITE-60

Options

Save Values

Manage Files

Exit

Select

Delete

Load

Close Menu

Scroll

Æ

Æ

Æ

Æ

Æ

Garde dans un fichier les paramètres de mesure enregistrés pour la trace sur l'écran de l'analyseur de

spectre optique.

Æ

Montre la liste de fichiers de donnés stockés dans la mémoire.

Æ

Sélectionne un fichier de données où on a stocké les paramètres de mesure décrits précédemment.

Permet d'effacer le fichier de données.

Charge les données d’un fichier.

Abandonne le menu d'archives de données.

Il permet de déplacer la fenêtre de visualisation des données des paramètres des porteuses WDM jusqu'à ce qu'apparaissent les 12 porteuses enregistrées.

Æ

Abandonne la fonction de mesure.

5.3.3 Fonction DFB MEASURE (Distributed Feedback)

Figure 17.-

Mesure de sources DFB

Paramètres de mesure

Peak Wavelength C'est la longueur d'onde dans laquelle se produit l'amplitude de pic.

Peak Amplitude Niveau de puissance pour le composant spectral de pic de la source DFB.

Page 28 09/2007

MANUEL D’UTILISATION. PROLITE-60

BW

SMSR

Mode Off

Center Off

Largeur de bande du principal composant spectral de la source

DFB. Dû à l’étroit spectre que présentent la majorité de sources

DFB, le résultat de cette mesure pour un laser non modulé sera limité par la résolution de largeur de bande de l’analyseur de spectre optique.

(Side Mode Suppression Ratio) C'est la relation d'ampleur entre le principal composant spectral et le plus grand mode latéral (non nécessairement le premier mode latéral) de la trace actuelle.

(Mode Offset) Longueur d'onde de séparation entre le principal composant spectral et le plus proche mode plus grande de la trace actuelle. Les valeurs négatives indiquent que le plus proche mode plus grand tombe à gauche du mode principal et les valeurs positives que tombe à droite.

(Center Offset) Il indique comment le mode principale s'adapte à la séparation définie par le stop band. Cette valeur est la différence entre la longueur d'onde du composant spectral principal et la moyenne des longueurs d'onde de la composante plus grande et de la plus petite au stop band.

Stop Band C'est la séparation en longueur d'onde existante entre les modes latérales supérieurs et inférieurs adjacents au mode principal.

Accès au menu d'archives de données.

File

Options

Save Values

Manage Files

Select

Delete

Load

Close Menu

Exit

Æ

Æ

Æ

Æ

Garde dans un fichier les paramètres de mesure enregistrés pour la trace sur l'écran de l'analyseur de spectre optique.

Æ

Montre la liste de fichiers de donnés stockés dans la mémoire.

Æ

Sélectionne un fichier de données où on a stocké les paramètres de mesure décrits précédemment.

Æ

Permet d'effacer le fichier de données.

Charge les données d’un fichier.

Abandonne le menu d'archives de données.

Abandonne la fonction de mesure

MANUEL D’UTILISATION. PROLITE-60

5.3.4 Fonction FP MEASURE (Fabry-Perot)

Figure 18.- Mesure de sources FP

Paramètres de mesure

Mean Lambda

) C'est le centre de masses correspondant aux points de la trace.

Peak lambda Longueur d'onde dans on trouve la valeur de pic du spectre de la source FP.

Mode Spacing C’est la séparation moyenne en longueur d'onde entre les composants spectraux individuels de la source FP.

FWHM (Full Width at Half Maximum) définit le large spectral pour les points de puissance-moitié (diminution de -3dB) du FP, considérant une distribution Gaussienne basée sur le λ

et le σ defini.

Power Résultat de l'intégration de l'énergie dans la marge de longueurs d'onde représentée.

Peak Amplitude

Niveau de puissance pour le pic de la source FP.

Sigma (σ) Valeur équivalente de la largeur spectrale du FP pour une distribution Gaussienne, basée sur le λ

défini précédemment.

File

Options

Save Values

Accès au menu d'archives de données.

Manage Files

Æ

Garde dans un fichier les paramètres de mesure enregistrés pour la trace sur l'écran de l'analyseur de spectre optique.

Æ

Montre la liste de fichiers de données stockées dans la mémoire.

Page 30 09/2007

MANUEL D’UTILISATION. PROLITE-60

Select

Æ

Sélectionne un fichier de données où on a stocké les paramètres de mesure décrits précédemment.

Close Menu

Exit

Delete

Load

Æ

Æ

Æ

Æ

Permet d'effacer le fichier de données.

Charge les données d’un fichier.

Abandonne le menu d'archives de données.

Abandonne la fonction de mesure

5.3.5 Fonction OA MEASURE (Optical Amplifiers)

Figure 19.- Mesure d'amplificateurs optiques.

PROCÉDURE DE MESURE

1.- Relier la source à l'entrée de l'analyseur de spectre optique (OSA) et pousser le

Start.

On enregistre la réponse spectrale de la source optique qui est dessinée en couleur bleue.

2- Relier la sortie de l'amplificateur à l'entrée de l'analyseur de spectre optique (OSA) et pousser le Start.

On représente la réponse spectrale de l'amplificateur optique en couleur verte, qui est superposée avec la précédente pour sa comparaison.

MANUEL D’UTILISATION. PROLITE-60

Figure 20.- Menu de configuration des paramètres de mesure.

Paramètres de mesure

Pour chaque porteuse WDM (Wavelength Division Multiplexing) :

λ

Longueur d'onde où elle est située (nm)

PWR Niveau de puissance (dBm).

SNR Mesure de la relation signal-bruit optique (SNR).

GAIN

SETUP Menu

Options

Différencie dans chaque

λ

mesurée entre la sortie et l'entrée.

Accès au menu de configuration des paramètres de mesure.

Start Lambda (nm)

Æ

Établit la longueur d'onde initiale du balayage.

Stop Lambda (nm)

Æ

Établit la longueur d'onde finale du balayage.

Peak Excursion (dB) Æ Choisit la valeur de l'excursion de pic. C'est le parcours en ampleur que la trace doit décrire depuis le minimum jusqu'au maximum pour être considérée comme un bout.

Des faibles valeurs permettent de détecter un plus grand nombre de signaux mais aussi peut être vues touché par le niveau de bruit de fond.

Peak Threshold (dBm) Æ Sélectionne la valeur seuil de pic. Les niveaux de puissance sous ce seuil ne sont pas considérés pendant la recherche de pics.

Noise Level (nm)

Æ

Choisit la valeur de déplacement (offset) pour la mesure du bruit de fond. Cette valeur est utilisée pour le calcul du

SNR optique.

Page 32 09/2007

MANUEL D’UTILISATION. PROLITE-60

Close Menu

Æ

Abandonne le menu de configuration des paramètres de mesure.

File

Æ

Accès au menu d'archives de données.

Options

Save Values

Manage Files

Exit

Select

Delete

Load

Close Menu

Æ Garde dans un fichier les paramètres de mesure enregistrés pour la trace sur l'écran de l'analyseur de spectre optique.

Æ

Montre la liste de fichiers de données stockées dans la mémoire.

Æ

Sélectionne un fichier de données où on a stocké les paramètres de mesure décrits précédemment.

Æ

Permet d'effacer le fichier de données.

Æ

Charge les données d’un fichier.

Æ

Abandonne le menu d'archives de données.

Æ

Abandonne la fonction de mesure.

MANUEL D’UTILISATION. PROLITE-60

Page 34 09/2007

MANUEL D’UTILISATION. PROLITE-60

6 TÉLÉCONTRÔLE

Il permet le télécontrôle des fonctions de l'appareil à travers d’un réseau ethernet, pour cela:

1) Configurer les paramètres du réseau local dans le PROLITE-60 (IP, type de serveur, etc..).

2) Relier PROLITE-60 au réseau de données. réseau et en accédant à l'IP spécifié pour appareil.

Figure 21.- Web Server PROLITE-60.

Le Web Server du PROLITE-60 offre les suivantes fonctions:

Traces :

Images:

Obtention de données de mesure des traces mémorisées.

Visualisation de traces préalablement saisies.

Remote Mode:

Opérations de visualisation de traces en mode télécontrôle.

Upgrade: Permet de récupérer les archives précédentes d’un firmware mis à jour.

L'option

Recover Traces permet de récupérer les données relatives aux traces de mesure mémorisées, pour chaque type de mesure: WDM, DFB, LED, FP ou OA, seront montré jusqu'à un maximum de neuf registres, et en choisissant apparaîtra un listing de toutes les valeurs enregistrées.

MANUEL D’UTILISATION. PROLITE-60

Figure 22.- Web Server PROLITE-60. Récupère les données des traces mémorisées.

Le PROLITE-60 peut stocker dans la mémoire jusqu'à dix-neuf images en format

JPEG, correspondant aux traces visualisées dans l'écran de l'appareil. Quand on fait clic sur une trace mémorisée, celle-ci est montrée dans le moniteur du Web Server.

Figure 23.- Web Server PROLITE-60. Récupère les images de traces mémorisées.

Page 36 09/2007

MANUEL D’UTILISATION. PROLITE-60

Il permet d'accéder au mode de télécontrôle du PROLITE-60. L'utilisateur peut choisir les traces et ordonner les opérations depuis un ordinateur éloigné.

L'accès au mode de télécontrôle depuis le Web Server requiert d'un ID (nom de l'utilisateur) et une clé d'accès (par défaut : abcdefg).

Figure 24.- Web Server PROLITE-60. Accès au mode de télécontrôle.

Il permet d'opérer les fonctions basiques de l’appareil : MARKER, SPAN, TRACE,

AMPLITUDE et introduire des valeurs numériques comme si on agissait directement sur les contrôles du panneau frontal de l'appareil. Pour opérer avec les traces choisir au moyen de la souris chacune trace à visualiser avec un clic sur le clavier alphanumérique qui est représenté dans l'écran du Web Server du PROLITE-60.

Faire clic sur la touche (PLAY) pour que l'appareil effectue un nouveau balayage du signal d’entrée ou bien sur la touche pour rafraîchir les données qui apparaissent dans l’écran. De cette manière, on met à jour l'information dans le cas qu'un même appareil est opéré par différents utilisateurs par télécontrôle.

Save trace: Il permet de mémoriser les traces qui apparaissent dans l’écran à la mémoire de l’appareil.

Last Users: Listing des derniers utilisateurs qui ont accédé à l'appareil et les commandes qui ont été exécutés.

MANUEL D’UTILISATION. PROLITE-60

Figure 25.- Web Server PROLITE-60. Contrôle des traces en mode télécontrôle.

Il permet à l’utilisateur le télédéchargement dans l'appareil des archives qui contiennent la mise à jour du firmware. De cette manière, une mise à jour manuelle du

firmware sera possible depuis le menu UPGRADE.

Figure 26.- Web Server PROLITE-60. Récupère une version firmware après le mis à jour.

Page 38 09/2007

MANUEL D’UTILISATION. PROLITE-60

7 ENTRETIEN

Cette partie du manuel décrit les méthodes de maintenance et de recherche des pannes.

7.1 Méthode de maintenance

L'entretien courant à exécuter par l'utilisateur revient au nettoyage du boîtier et le changement de la batterie. Le reste des opérations sera exécuté par les responsables autorisés ou par du personnel spécialisé dans le service des instruments.

7.1.1 Nettoyage du boîtier

PRÉCAUTION

Au nettoyage, ne pas employer d'hydrocarbures aromatiques ou des solvants chlorés. Ces produits peuvent attaquer les matières plastiques utilisées dans la

construction du boîtier.

Nettoyez le boîtier avec une solution faible de détersif à l'eau, appliquée avec un chiffon doux. Sécher complètement avant d'utiliser l'appareil de nouveau.

PRÉCAUTION

Nettoyer les contacts de la batterie avec un chiffon sec. Ne jamais employer un

chiffon humide ou mouillé.

PRÉCAUTION

N'utilisez pas pour le nettoyage du panneau avant et en particulier les viseurs, alcool ou ses dérivés, ces produits peuvent attaquer les propriétés mécaniques des matériaux diminuer leur période de la vie utile.

7.2 Les composants non remplaçables par l’utilisateur

7.2.1 Fusibles non remplaçables par l’utilisateur

Ce fusible ne doit être remplacé que par du personnel spécialiste. Son identificateur de position et caractéristiques sont les suivantes :

F001: FUS 7 A T 125 V SMD

F002: FUS 7 A T 125 V SMD

MANUEL D’UTILISATION. PROLITE-60

Page 40 09/2007

MANUEL D’UTILISATION. PROLITE-60

APPÉNDIX A : GUIDE RAPIDE D’UTILISATION

Comment opérer avec les marqueurs (MARKER)

Marqueur absolu MKR1

1. Pousser [2] pour activer le champ MKR1.

2. Choisir la longueur d'onde (λ) du marqueur MKR1 au moyen du clavier alphanumérique alphanumérique [7], ou en tournant directement le sélecteur rotatif

[8].

3. En poussant le sélecteur rotatif [8], le marqueur MKR1 est placé directement sur la valeur maximale de la trace active.

Marqueur relatif MKR

1. Pousser [2] encore une fois, pour activer le ∆MKR.

2. Choisir la longueur d'onde (λ) du marqueur ∆MKR au moyen du clavier alphanumérique alphanumérique [7], ou en tournant directement le sélecteur rotatif

[8].

3. En poussant le sélecteur rotatif [8], le marqueur ∆MKR est placé directement sur la valeur maximale de la trace active.

Comment opérer avec l’expansion (SPAN)

1. Pousser [3] pour activer le champ Span.

2. Choisir la valeur numérique au moyen du clavier alphanumérique alphanumérique

[7]: (10, 20, 50, 100, 200, 400 nm).

3. On peut aussi choisir la valeur du Span en poussant la touche [3]. Quand on pousse cette touche consécutivement la valeur change de manière cyclique.

Chaque fois qu'on change le Span, le nouveau Span sera centré sur la longueur d'onde (λ) du marqueur MKR1.

MANUEL D’UTILISATION. PROLITE-60

Comment opérer avec les traces (TRACE)

1. Pousser [4] pour activer le champ Trace.

2. En côté droit de l'écran apparaît une colonne avec 11 petits carrés de couleurs.

Chaque carré correspond à une trace coloriée.

Carré (0): Il correspond à la trace de données (de couleur verte). Cette trace correspond à la valeur du signal d'entrée, mesure qui est rafraîchie dans chaque balayage.

En poussant la touche [4] quand le champ Trace est activé (en couleur rouge), est possible à choisir différents types de mesure : SIGNAL - > MAX. HOLD

- > MIN. HOLD - > AVERAGE - >…

Le mode choisi sera visualisé dans l'écran de mesure à moins que pour le mode

SIGNAL (opération normal).

Carrés (1) - (9): Ils correspondent aux traces mémorisées. Il est possible de copier la trace de données (0) à chacun des autres traces (depuis la 1 à la 9).

Le processus est bien simple. Toujours avec le champ Trace actif (en couleur rouge), pousser le sélecteur rotatif [8] simultanément avec une touche numérique

[7]. Par exemple, si on pousse le sélecteur rotatif [8] + la touche nombre (7), la trace (7) prendra la même valeur que la trace de données (0).

Toute trace mémorisée peut être visualisée et être éliminée de l'écran, simplement en poussant la touche numérique correspondante.

Carré (*) : Il correspond à la trace relative qui permet de mémoriser la différence entre la trace de données (0) et une des traces mémorisées (1) - (9). Pour mémoriser cette trace, toujours avec le champ Trace activé (en couleur rouge), pousser deux fois la touche numérique correspondant au numéro de trace choisie et ensuite, pousser la touche (

*

). Une nouvelle trace sera dessinée à l’écran dont la valeur est la différence entre la trace de données et la trace choisie de la mémoire.

Comment opérer avec l'ampleur (AMPLITUDE)

1. Pousser [5] pour activer le champ Scale.

2. Choisir 10 dB/div ou 2 dB/div en utilisant le clavier alphanumérique alphanumérique

[7] ou avec la touche [5].

3. Dans le mode de 10 dB/div apparaissent deux lignes discontinues horizontales qui indiquent le secteur de vue à l'écran à 2 dB/div.

Page 42 09/2007

MANUEL D’UTILISATION. PROLITE-60

Comment garder les écrans des traces comme archives JPEG

1. Pousser deux fois le sélecteur rotatif [8] tant que le mode Trace est activé.

2. On crée des archives JPEG qui contiennent l'information de l'écran complet.

3. Il sera possible d'accéder à cette image à travers le

WEB SERVER

.

Comment accéder au

WEB SERVER

1. Il est d'abord nécessaire de relier le PROLITE-60 à un réseau de données ethernet ou directement à un ordinateur en utilisant un câble adéquat.

2. Configurer les paramètres de réseau (IP, SERVEUR PROXY, etc..) pousser la touche FUNCTION -> SETTING -> GLOBAL ADJUSTMENTS -> NETWORK ADJ.

WEB SERVER

depuis l'ordinateur en utilisant un navigateur d'Internet

(IE, FireFox, Netscape…).