Aktakom AMM-1048 is a versatile digital multimeter with a wide range of features that make it ideal for both professional and home use. With its 3-3/4 digit 4000 count LCD display, it provides accurate and reliable readings for a variety of measurements, including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, and duty cycle. The built-in non-contact AC voltage detector and flashlight add to its versatility, making it a valuable tool for electrical troubleshooting and repair.
advertisement
Features
3-3/4 digit 4000 count) LCD display
Built-in non-contact AC voltage detector plus flashlight
Double Molded housing
CATIII 1000V
200mA/500V Resettable Fused current inputs and Overload protection on all ranges
Autoranging with auto power off
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.
Double insulation
Safety Precautions
1. Improper use of this meter can cause damage, shock, injury or death. Read and understand this users manual before operating the meter.
2. Make sure any covers or battery doors are properly closed and secured.
3. Always disconnect the test leads from any voltage source before replacing the battery or fuses.
4. Do not exceed the maximum rated input limits.
Input Limits
V DC or V AC
µA AC/DC
Resistance, Diode & Continuity Test
600V DC/AC
200mA/500V fast acting Resettable Fuse
600V DC/AC
5. Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC.
These voltages are considered a shock hazard.
6. Always discharge capacitors and remove power from the device under test before performing Diode,
Resistance or Continuity tests.
7. Remove the battery from the meter if the meter is to be stored for long periods.
Meter Description
1
6
1. Non-contact AC voltage detector probe tip
2. Non-contact AC voltage indicator light
2
3
Auto Ran g ing DMM
3. 3 3/4 Digit (4000 count)
4. MODE button
4
7
8
10
OFF
V
5. Function switch
6. Flashlight
5
A
AU
T
O
PO
W
ER O
FF
7. Flashlight button
8. Hz/%Duty button
9. Battery Cover
10. Test leads
9
www.tmatlantic.com
Specifications
Electrical Specifications
Function Range
DC Voltage 400mV,
4.000V,40.00V, 400.0V, 600V
Accuracy
(0.5% rdg + 3d)
(1.2% rdg + 3d)
AC Voltage
50-60Hz
DC Current
AC Current
50-60Hz
Resistance
4.000V, 40.00V
400.0V, 600V
400.0
µ A, 4000 µ A
40.00mA, 200.0mA
400.0
µ A, 4000 µ A
40.00mA, 200.0mA
400.0
4.000k
, 40.00k
, 400.0k
4.000M
40.00M
(1.0% rdg + 8d)
(2.3% rdg + 10d)
(2.0% rdg + 8d)
(2.5% rdg + 10d)
(0.8% rdg + 5d)
(1.2% rdg + 5d)
(5.0% rdg + 5d)
(10.0% rdg + 5d)
Capacitance
Frequency
4.000nF
40.00nF
400.0nF
4.000µF, 40.00µF, 200.0µF
9.999Hz, 99.999Hz, 999.9Hz,
9.999kHz,
0.5-99% Duty Cycle
Max input voltage 600V AC/DC
Diode Test Test current 1mA max., open circuit voltage of 1.5V typical
Continuity Check Audible signal if the resistance is <100
Display 4000 count 3 -3/4 digit LCD
Over range indication LCD displays “OL”
Polarity Minus (-) sign for negative polarity.
Low Battery Indication “BAT” symbol indicates low battery condition.
Input Impedance >7.5M
Ω (VDC & VAC)
AC Response Average responding
ACV Bandwidth 50Hz to 60Hz
Auto Power Off 15 minutes (approximately)
Fuse mA, µA ranges; 0.4A/600V fast acting Resettable Fuse
Batteries Two 1.5V AAA
Operating Temperature 32 o F to 104 o
Storage Temperature 14 o F to 122 o
F (0 o C to 40
F (-10 o o C)
C to 50 o C)
Weight
Size
Standard
145g
104x55x32.5mm
IEC61010-1 CAT III 1000V Pollution degree II, CE Approved
(5.0% rdg + 0.6nF)
(5.0% rdg + 30d)
(3.0% rdg + 15d)
(5.0% rdg + 25d)
(2.0% rdg + 5d)
(2.0% rdg + 5d)
www.tmatlantic.com
Operation
AC/DC VOLTAGE MEASUREMENTS
CAUTION: Do not measure AC/ DC voltages if a motor on the circuit is being switched ON or OFF.
Large voltage surges may occur that can damage the meter.
1. Set the function switch to the green V position.
2. Press the MODE button to indicate “DC” or “AC” on the display.
3. Touch the black test probe tip to the negative side of the circuit.
Touch the red test probe tip to the positive side of the circuit.
4. Read the voltage in the display
DC/AC CURRENT MEASUREMENTS
1. Set the function switch to the µA/mA position.
2. For current measurements up to 4000 µA DC/AC, set the function switch to the mA position
3. Press the MODE button to indicate “DC” / “AC” on the display.
4. Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.
5. Touch the black test probe tip to the negative side of the circuit.
Touch the red test probe tip to the positive side of the circuit.
6. Apply power to the circuit.
7. Read the current in the display
NOTE: 0.2A/500V fast acting Resettable Fuse current inputs and Overload protection on mA, µA ranges. No replacement required.
RESISTANCE MEASUREMENT
WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords.
1. Set the function switch to the Ω position.
2. Press the MODE button to indicate on the display.
3. Touch the test probe tips across the circuit or part under test. It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading.
4. Read the resistance in the display
CONTINUITY CHECK
WARNING: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them.
1. Set the function switch to the Ω position.
2. Press the MODE button to indicate on the display
3. Touch the test probe tips to the circuit or wire you wish to check.
4. If the resistance is less than approximately 150 , the audible signal will sound. If the circuit is open, the display will indicate “OL”.
DIODE TEST
1. Set the function switch to the Ω position.
2. Press the MODE button to indicate on the display.
3. Touch the test probes to the diode under test. Forward voltage will typically indicate 0.400 to 0.700V.
Reverse voltage will indicate “ OL ”. Shorted devices will indicate near 0V and an open device will indicate
“ OL ” in both polarities
www.tmatlantic.com
Capacitance Measurement
WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords. Never measure continuity on circuits or wires that have voltage on them.
1. Set the function switch to the “ Ω •))) ” position.
2. Press the SELECT button until “nF” appears in the display.
3. Press the RELATIVE button to zero the display
4. Connect the test leads to the capacitor to be measured.
5. Read the value on the display.
Frequency/Duty Cycle Measurement
1. Set the function switch to the “ HZ/DUTY” position.
2. Press the Hz/DUTY button once to display Duty Cycle %. Pressing the button again will toggle the display to frequency (Hz).
3. Touch the test probe tips to the circuit under test. Be sure to observe the correct polarity (red lead to positive, black lead to negative).
4. Read the value on the display.
Non-Contact AC Voltage Measurements
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation
1. Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet.
2. If AC voltage is present, the detector light will illuminate.
NOTE : The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor.
NOTE : The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation
Flashlight
Press and hold the top button to turn the flashlight on. Release the button to turn the flashlight off.
AUTO POWER OFF
The auto off feature will turn the meter off after 15 minutes.
REPLACING THE BATTERY
1. Remove the bottom cover and secure the screw.
2. Replace old battery with fresh Two 1.5V AAA type battery.
3. Replace the bottom cover and secure the screw.