Minka-Lavery 4561-098 Tyson's Gate - 4 Light Semi Flush Instruction Manual

Add to my manuals
3 Pages

advertisement

Minka-Lavery 4561-098 Tyson's Gate - 4 Light Semi Flush Instruction Manual | Manualzz

INSTALLATION INSTRUCTIONS

Item#4561-098 (Convertible Lamps for

Pendant

) (New. 12/11/2017)

READ AND SAVE THESE INSTRUCTIONS

W

A R N I N G ! S H U T P O W E R O F F A T F U S E O R C I R C U I T B R E A K E R .

AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

PREPARATION (Fig. 1) Fig. 1

1. Shut off the power at the fuse box or circuit breaker. If necessary, remove the old fixture, including the mounting hardware.

2. Carefully remove the fixture from the carton and check that all

Set# A-020-A parts are included as shown in the illustration.

ASSEMBLING THE FIXTURE WITH CHAIN LOOP (Fig. 2)

-Circular Strap

-Ground Screw

3. Place the candle cover (R) over the socket (Q) of the fixture body.

4. Install light bulb(s) (K) (not included) in accordance with the fixture’s specification. (DO NOT EXCEED THE MAXIMUM

WATTAGE RATING!) (NE PAS DEPASSER LA PUISSANCE

NOMINALE MAXIMALE!).

-Mounting Screw*2

5. Through screw (L) into iron plate (M), plastic gasket (S), glass panel (O) and plastic gasket (S), then secure into square tube (J).

6. Determine the desired hanging height and thread rods (F1, F2 and F3) to the nipple (I) of the fixture body. Then attach loop (H1) by screwing in to rod (F1). Note: remove the nipple if installing with one 6” rod only.

7. Attach the quick link (G) connect to loop (H1) and loop (H2) on the canopy (D), carefully feed the wire over loop (H1), quick link (G) and loop (H2).

8. Thread screws (A) into the pre-drilled holes in the circular strap

(B) spaced the same distance apart as the holes in the canopy

(D).

9. Attach the circular strap (B) to the Junction box using mounting screws (C) (Size: #8-32N*L0.5”). The side of the circular strap marked “GND” must face out.

10. The support cable is provided to support the weight of the fixture while wiring. Align the fixture to circular strap (B) and attach hook

(T) on the end of support cable (N) into a slot located on circular strap (B). Carefully allow the support cable (N) to support the weight of the fixture while wiring (Fig.1).

F2

H1

F1

F3

H2

CONNECTING THE WIRES (Fig. 3)

11. At this point, connect the electrical wires as shown in figure 3, making sure that all wire connectors are secured. If your outlet has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the circular strap using the green screw provided.

12. Tuck the wire connectors neatly into the ceiling Junction Box and then raise the canopy all the way to the ceiling.

COMPLETING THE INSTALLATION (Fig. 1)

Candle Cover#24049P-84

Fig. 3

13. Thread canopy (D) into screws (A), and secure with knurled knobs

(E).

Your installation is now complete. Return power to the junction box and test the fixture.

FIXTURE

WIRES

Black or

Smooth

FIXTURE

WIRES

White or

Ribbed

Note: Illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.

HOUSE

WIRES

Black

(Hot)

A

B

C

N

D

E

G

Q

R

HOUSE

WIRES

White

(Neutral)

T

Rod# W30-1-84*1(F1)

W30-1-84*2(F2)

W30-H-84*1(F3)

K

I

J

L

M

FIXTURE

WIRES

Bare

Copper

(Ground)

S

HOUSE

WIRES

Green

(Ground)

O

S

Page: 1/3

LA-2843E

Fig.2

H2

F1

A

C

E

G

H1

D a. Hardware Bag:

A. Screw*2

B. Circular Strap*1

D. Canopy *1

C. Mounting Screw*2

E. Knurled Knob*2

H. Loop*2

G. Quick Link*1

B D C

B

A b. Hardware Bag:

F1. ROD 12"*1

F2. ROD 12"*2

F3. ROD 6"*1

Page: 2/3

F1

F2

LA-2843E

F3

E G H

INSTALLATION INSTRUCTIONS

Item#4561-098(Convertible Lamps for

Semi Flush Mount

) (New. 12/11/2017)

READ AND SAVE THESE INSTRUCTIONS

W

A R N I N G ! S H U T P O W E R O F F A T F U S E O R C I R C U I T B R E A K E R .

AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

PREPARATION (Fig. 4&Fig. 5) Fig. 4

1. Loosen hex nut (U) by using wrench (Z). Carefully remove washer (W), lock washer (X), L-type part (N1),metal plate (Y), canopy (D) and loop (H2)(Fig.5). Cut down a length of wire if the wire is too long.

2. Secure metal tube (P) onto nipple (I).

3. Thread canopy (D), metal plate (Y), L-type part (N1) , lock washer (X), washer (W) and hex nut (U) into the nipple at the metal tube (P).Then secure hex nut (U) by using wrench (Z).

(Fig. 4)

4. Thread screws (A) into the pre-drilled holes in the circular strap (B) spaced the same distance apart as the holes in the canopy (D). (Fig. 4)

5. Attach the circular strap (B) to the Junction box using mounting screws (C) (Size: #8-32N*L0.5”). The side of the circular strap marked “GND” must face out. (Fig. 4)

ASSEMBLING THE FIXTURE WITH CHAIN LOOP (Fig. 2)

6. Place the candle cover (R) over the socket (Q) of the fixture body.

7. Install light bulb(s) (K) (not included) in accordance with the fixture’s specification. (DO NOT EXCEED THE MAXIMUM

WATTAGE RATING!) (NE PAS DEPASSER LA PUISSANCE

NOMINALE MAXIMALE!).

Set# A-020-A

-Circular Strap

-Ground Screw

-Mounting Screw*2

Z

C

X

8. Through screw (L) into iron plate (M), plastic gasket (S), glass panel (O) and plastic gasket (S), then secure into square tube

(J).

9. The support cable is provided to support the weight of the fixture while wiring. Align the fixture to circular strap (B) and attach hook (T) on the end of support cable (N) into a slot located on circular strap (B). Carefully allow the support cable

(N) to support the weight of the fixture while wiring.

CONNECTING THE WIRES (Fig. 3)

10. At this point, connect the electrical wires as shown in figure 3, making sure that all wire connectors are secured. If your outlet has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the circular strap using the green screw provided.

11. Tuck the wire connectors neatly into the ceiling Junction Box and then raise the canopy all the way to the ceiling.

COMPLETING THE INSTALLATION (Fig. 4)

12. Thread canopy (D) into screws (A), and secure with knurled knobs (E).

Your installation is now complete. Return power to the junction box and test the fixture.

Fig. 5

Z

I

Candle Cover# 24049P-84

Note: Illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.

H2

E

D

A

B

U

W

N

N1

Y

P

K

R

Q

J

X

N1

D

Y

L

M

S

T

O

S

Wrench#WRH-Y-89

U

W

LA-2843E

Page: 3/3

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Download PDF

advertisement