Installation Guide

DEVIreg™ 534

Electronic Thermostat www.DEVI.com

DEVIreg™ 534

1

4

5

2

3

Table of Contents

Introduction . . . . . . . . . . . . . . .

1.1

Technical Specifications . . . . .

1.2

Safety Instructions . . . . . . . .

Mounting Instructions . . . . . . . . .

Settings . . . . . . . . . . . . . . . . .

Warranty . . . . . . . . . . . . . . . . .

Disposal Instruction . . . . . . . . . .

1 Introduction

DEVIreg™ 534 is an electronic timer temperature controller, specially designed for floor heating systems. The thermostat is provided with a combination of a floor sensor and a room sensor to measure and control the desired floor and room temperature. It can be either flush-mounted or surface-mounted.

Once set, the thermostat will automatically adjust the heat to meet your comfort requirements by measuring the floor temperature and combining it with the measured air temperature regardless of changing weather conditions.

14

14

6

9

3

4

6

Installation Guide 3

4

DEVIreg™ 534

The thermostat has buttons for adjusting the temperature setting, and a LED indicator showing standby periods

(green light) and heating periods (red light).

More information on this product can also be found at: devireg.devi.com

1.1

Operation voltage

Standby power consumption

Ambient temperature

Frost protection temperature

Technical Specifications

Relay:

Resistive load

Inductive load

Sensing units

Sensing values:

0°C

25°C

50°C

Hysteresis

220-240V~, 50Hz

Max 0.30W

Max 15A / 3450W @ 230V cos φ= 0.3 max 1A

NTC 15kOhm at 25°C

42kOhm

15kOhm

6kOhm

± 0.4°C with floor sensor only

-10°C to +30°C

5°C -

Installation Guide

DEVIreg™ 534

Temperature range 15-32°C with floor sensor only

Cable specification max

1x4mm

2

or 2x2,5mm

2

Ball pressure temperature 75°C

Pollution degree 2 (domestic use)

Type

Storage temperature

IP class

Protection class

Dimensions

Weight

1C

-20°C to +65°C

31

Class II -

85 x 85 x 54mm (in-wall depth: 24mm)

107g

The product complies with the EN/IEC Standard "Automatic electrical controls for household and similar use":

EN/IEC 60730-1 (general)

EN/IEC 60730-2-7 (timer)

EN/IEC 60730-2-9 (thermostat)

Installation Guide 5

6

DEVIreg™ 534

1.2

Safety Instructions

Make sure the mains supply to the thermostat is turned off before installation.

Please also note the following:

The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.

The thermostat must be connected to a power supply via an all-pole disconnection switch.

The sensor is to be considered as live voltage. Have this in mind if the sensor must be extended.

Always connect the thermostat to continuous power supply.

Do not expose the thermostat to moisture, water, dust, and excessive heat.

2 Mounting Instructions

Please observe the following placement guidelines:

Place the thermostat at a suitable height on the wall (typically 80-170cm.).

Installation Guide

DEVIreg™ 534

The thermostat should not be placed in wet rooms. Place it in an adjacent room.

Always place the thermostat according to

NFC15100 - part 7-701.

Do not place the thermostat in a way that it will be exposed to direct sunlight.

Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor.

Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings.

Equally distant and >2cm from two heating cables.

The conduit should be flush with the floor surface countersink the conduit if necessary.

Route the conduit to the connection box.

The bending radius of the conduit must be min 50mm.

Installation Guide 7

DEVIreg™ 534

Follow the steps below to mount the thermostat:

1. Open the thermostat: eg™550 eg™550 devir devir

8

Gently press the release tab in the bottom of the thermostat by a flat object.

Carefully pull off the front cover.

2. Connect the thermostat according to the connection diagram.

N

N

LOAD

L

L

LOAD

NTC

Mains

220-240V~

Max. Load

15 (1) A

D534

IP31

-10T30

Standby maximum 0.3W

Installation Guide

DEVIreg™ 534

The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.

Note: Always install the floor sensor in a conduit in the floor.

3. Mount and reassemble the thermostat.

Fasten the thermostat to a socket or an exterior wall box by driving the screws through the holes in each side of the thermostat.

Tighten the screws to fasten the thermostat.

4. Turn on the power supply.

Initially main supply the thermostat for 15 hours to fully charge the battery. The current time and day is then kept for 80 days if mains supply is off. All other settings are stored permanently.

3 Settings

Sensor: How to specify whether an external floor sensor, the built-in room sensor or both is used to control the floor heating

Note: The floor sensor option is selected by default.

Installation Guide 9

10

DEVIreg™ 534

1. Press the installation button D with a blade end.

eg™550 eg™550 devir devir

D

2. Press the button.

3. Select one of the following options using the

▲▼

buttons:

If only a floor sensor is used, choose:

The built-in room sensor is not used.

This option is suitable for rooms in which a constant floor temperature is required, e.g. in a bathroom.

If both a room sensor and a floor sensor is used, choose:

This option is suitable for all rooms but wet rooms. The thermostat must be installed in the same room as the floor sensor and the heating elements.

Installation Guide

DEVIreg™ 534

If only a room sensor is used, choose .

This option is not recommendable due to an increased risk of overheating the floor. The thermostat must be installed in the same room as the heating elements.

4. To accept the new selected sensor mode, press .

5. Press installation button D to configure settings.

6. If you have chosen the floor sensor or room/floor sensor option, press

▲▼

(up/down) buttons to continue to the next setting.

How to set the maximum floor temperature

Special condition: This setting only applies if a floor sensor is used (the floor sensor or room/floor sensor option has been set).

Note: The maximum floor temperature is set to 28°C by default.

1. To change the default temperature setting - press the

button.

2. Select the new temperature by using the

▲▼

buttons.

3. To accept the new selected temperature, press .

Installation Guide 11

DEVIreg™ 534

4. Press installation button D to configure settings.

eg™550 eg™550 devir devir

D

5. Press

▲▼

(up/down) buttons to continue the next setting.

Note: Please contact the floor supplier before changing the maximum floor temperature and be aware of the following:

The floor temperature is measured where the sensor is placed.

The temperature of the bottom of a wooden floor can be up to 10 degrees higher than the top.

Floor manufactures often specify the max temperature on the top surface of the floor (usually 27-28˚C).

Always use a floor sensor or a room + floor sensor combination to control floor heating. Without a floor sensor, the temperature control may be less accurate and you risk overheating the floor.

12 Installation Guide

DEVIreg™ 534

Thermal resistance

[m2K/W]

0.05

Examples of flooring

0.10

8 mm HDF based laminate

14 mm beech parquet

0.13

22 mm solid oak plank

< 0.17

Max. carpet thickness suitable for floor heating

0.18

22 mm solid fir planks

Details

> 800 kg/m

3

650 - 800 kg/m 3

> 800 kg/m

3 acc. to EN

1307

450 - 650 kg/m

3

Approximate setting for

25˚C floor temperature

28˚C

31˚C

32˚C

34˚C

35°C

How to define the temperature scale

You can select the display type. The choice is either numerical scale 1-6 or Celsius scale 15° to 28°. Default is Celsius scale. When selecting Celsius, the display will show the actual temperature at the floor sensor.

1. To change the default temperature scale, press the button.

2. Select a scale, use the

▲▼

buttons.

3. To accept the selected temperature scale, press .

Installation Guide 13

14

4

DEVIreg™ 534

4. If desired, go back or forward through your installation settings by pressing the

▲▼

(up/down) buttons.

5. Press installation button D to exit the installation mode.

6. Put the frame and front back on.

Warranty

2

Y E A R

5 Disposal Instruction

Installation Guide

DEVIreg™ 534

Danfoss A/S

Electric Heating Systems

Ulvehavevej 61

7100 Vejle

Denmark

Phone: +45 7488 8500

Fax: +45 7488 8501

E-mail: [email protected]

www.DEVI.com

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logotype are trademarks of Danfoss A/S. All rights reserved.

0809XXXX & VIGDS102 Produced by Danfoss © 0

5

/2012

Thermostat Room

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement