Copyright
© Diebold Nixdorf
All rights, including rights of translation, reproduction by printing, copying or similar methods, in part or in whole, are reserved.
Any violations give rise to a claim for damages. All rights reserved, particularly in relation to the grant of a patent or the registration of a utility model. Subject to availability and technical modifications. All names of hardware and software products mentioned in this manual are trade names and/or trademarks of their respective manufactures.
Contents
Example: Pillar mounting of 19” and optional scale platform ......................................48
17 Removing the protection foil at the Display and Front surface ...........................74
BEETLE/ iSCAN EASY eXpress+
1 About this Manual
This manual refers to technically trained personnel only.
It provides all necessary site preparation information for installing the device at site.
The responsibility for all technical and special prerequisites for the installation of the device is borne by the customer. A detailed list of customer responsibilities is given in this manual.
Installation as well as connection of BEETLE /iSCAN EASY eXpress + may only be executed by technically trained personnel.
The safety instructions given in this document should be strictly followed when handling the
BEETLE /iSCAN EASY eXpress + . Further safety, installation, and maintenance instructions can be found in the manuals supplied with the components.
In case of doubts or questions please contact Diebold Nixdorf.
1.1 Symbols
DANGER
This warning note describes a hazard with a high degree of risk, which, if not avoided, will result in death or grave bodily injury.
WARNING
This warning note describes a hazard with a medium degree of risk, which, if not avoided, will result in death or grave bodily injury.
CAUTION
This warning note describes a hazard with a low degree of risk, which, if not avoided, will result in death or grave bodily injury.
NOTICE
This note provides application tips and information that help prevent errors and material damage.
1
BEETLE/ iSCAN EASY eXpress+
2 Warranty
Diebold Nixdorf generally guarantees a warranty engagement for 12 months beginning with the date of delivery. This warranty engagement covers all damages which occur despite a normal use of the product.
Damages because of
improper or insufficient maintenance,
improper use of the product or unauthorized modifications of the product,
inadequate location or surroundings will not be covered by the warranty.
For further information on the stipulation consult your contract.
All parts of the product which are subject to wear and tear are not included in the warranty engagement. For detailed warranty arrangements please consult your contract documents.
2
BEETLE/ iSCAN EASY eXpress+
3 Unpacking and Checking the System
Take the system out of the package and the card board. Be careful to the signal.
Verify that the scope of delivery is identical to the information on the delivery ticket.
Should you notice any
transport damages or
discrepancies between package contents and delivery ticket or
functional defects, please inform your contracting parties or the branch office of Diebold Nixdorf immediately.
Please indicate the number of your delivery ticket and delivery ticket position and serial number of the respective device.
NOTICE
We recommend to save the original packaging for transport at a later time
(protection from impact and shock).
3.1 Serial number
You will find the serial number on the label, which is attached to the right side of the housing
Type plate with serial number
3
BEETLE/ iSCAN EASY eXpress+
BEETLE /iSCAN eXpress+ 15“, 19“
Diebold Nixdorf Systems GmbH
Wohlrabedamm 31
DE-13629 Berlin
Model / 型号 / 型號
: iSCAN EASY eXpress+ No:15
Product / 品名 : Self Checkout Terminal / 自助结账机 / 自助結帳系統
PN / 编号 / 編號 : 01750300948
S/N 5300000000
D31294
RoHS
Made in Germany
德国制造 / 德國製造
Diebold Nixdorf Systems GmbH
Wohlrabedamm 31
DE-13629 Berlin
Model
/ 型号 / 型號
: iSCAN EASY eXpress+ No:19
Voltage
Current
/
/
电压
电流
Frequency /
/
/
Product / 品名 : Self Checkout Terminal / 自助结账机 / 自助結帳系統
PN / 编号 / 編號 : 01750300948
電壓
電流
频率 /
: 100-240V
: 1.4 – 0.7A
頻率 : 60-50Hz
S/N 5300000000
D31294
RoHS
Made in Germany
德国制造 / 德國製造
BEETLE /iSCAN eXpress+ 27“
Diebold Nixdorf Systems GmbH
Wohlrabedamm 31
DE-13629 Berlin
Model: iSCAN EASY eXpress+ No:27
Product : Self Checkout Terminal
PN: 0175xxxxx
Voltage: 100-240V
Current: 2.4 – 1.0A
Frequency
:
60-50Hz
Made in Germany
S/N 5300000000
With SENSORMATIC- Article Surveillance System
4
BEETLE/ iSCAN EASY eXpress+
5
BEETLE/ iSCAN EASY eXpress+
4 ESD (Electrostatic Sensitive Devices)
Electrostatic sensitive devices (ESD) may be marked with this sticker.
When you handle components fitted with ESDs, you must observe the following points under all circumstances:
Unplug the power before inserting or removing components containing ESDs.
While working with ESDs you must discharge yourself by using an ESD wrist strap or grounding cable to connect yourself at all times to the earth connector of power socket or a grounded object.
Place all components containing ESDs on a static-safe base.
The equipment and tools you use must be free of static charges.
Always hold boards with ESDs by their edges. Do not touch the components.
Never touch pins or conductors on boards fitted with ESDs.
6
BEETLE/ iSCAN EASY eXpress+
5 Important Notes
Appliances supplied by Diebold Nixdorf comply with the respective safety regulations for data-processing installations and information technology installations, including electrical office equipment for use within an office environment.
WARNING
Risk of injury! Whenever work of any kind is done on the device, as well as when data cables are plugged and unplugged, the device must be completely disconnected from the line voltage.
NOTICE
The appliance should be used only when the front door is closed.
The sockets of the house installation must be easily accessible.
Appliances may only be repaired by authorized technicians .
Unauthorized opening of the housing or inexpert repairs can result not only in considerable personal danger, but will also invalidate your warranty and liability protection.
Always consult the available documentation before doing any work with this appliance.
If this device is brought from a cold environment into a heated place of business, condensation may occur. Before operation, the device must be completely dry.
Therefore, an acclimatization period of at least two hours must be adhered to.
Always lay the supply leads and cables in such a way that they cannot be stepped on or tripped over.
Exchange damaged cables immediately.
In order to completely disconnect the device from the power supply, use the circuit breaker in the fuse box or building installation.
Sensitive data cables must not be marked.
Make sure that no objects (such as paper clips) can reach the interior of the device, since electrical shocks or short-circuits could result.
To avoid overheating of the system ensure that the BEETLE /iSCAN EASY eXpress + receives adequate ventilation.
During an electrical storm, data cables should not be plugged in or unplugged.
Keep the device away from vibrations, airstreams/ventilations, dust, humidity and heat.
Ensure that used parts are disposed of in an environmentally friendly manner.
7
BEETLE/ iSCAN EASY eXpress+
In case of an accident (such as a damaged housing, entry of liquids or foreign objects), switch the device off and use the separator to completely remove the device from power.
The appliance and other information technology hardware should only be connected to electrical supply networks with a separate protective earth wire (PE). This type of electrical supply network is referred to as a TN-S network. Do not use PEN conductors.
Also follow the recommendations set forth in DIN VDE 0100 Part 540, Appendix C2 as well as EN50174-2, §5.4.3, National Electrical Code ANSI/NFPA 70-2005 and
Canadian Electrical Code, Part I, CSA C22.1-02. This will help prevent malfunctions.
Turn off the device when working on the cutter of the printer.
Always keep the ventilation slots free of obstruction to ensure adequate air circulation and avoid overheating.
Transport the appliance only in its original packaging (to protect it against knocks and bumps).
If a lithium battery is supplied with the appliance, ensure that the battery is replaced with an equivalent type. Otherwise there is danger of explosion!
Lithium batteries may only be replaced with identical types or other types recommended by the manufacturer.
Batteries must be disposed of according to local regulations on the disposal of special waste.
5.1 Connecting Peripherals
Use only shielded cables when connecting devices to the system to ensure compliance with international Rules and Regulations for radiated emission as well as to achieve a high immunity against external disturbances.
8
BEETLE/ iSCAN EASY eXpress+
6 Tools You Need
Keep the following tools at hand for working at the system.
Torx screw driver Size: T6, T8, T10, T20, T25
Socket wrench Wrench size: 5,5mm (M3), 7mm (M4), 8mm (M5)
9
BEETLE/ iSCAN EASY eXpress+
7 Customer Requirements
Before the BEETLE /iSCAN EASY eXpress + installation can be started, the customer is held responsible to provide the following:
NOTICE
Run the kiosk system in attended areas only!
•
Installation of EFT (Diebold Nixdorf just provides the power connection).
•
The device must not be installed near heat sources.
•
If the device will be fixed directley to the floor appropriate materials are requiered.
•
Appropriate drawings concerning location of the equipment as well as site wiring
(power and communications, paths and lengths). Location of other equipment that may generate electrical noise, electromagnetic interference, or heat.
•
Providing of dowels and screws for installation of the base plate at the desk.
•
Provision and installation of all communication cables wall jacks, special connectors and associated hardware.
•
Provision and installation of necessary power distribution boxes, conduits, grounds, lightning protection devices, and associated hardware.
•
Ensure that all applicable codes, regulations, and laws (including, but not limited to, electrical, building, safety, and health) are adhered to.
•
Provision and installation of auxiliary power or other equipment as required.
•
Provision of storage or service as required.
•
Provision of a level floor to locate the device. The system has to be stable and must not tilt. The maximum incline must not exceed 2%. The feet of the unit can overcome a height difference of up to 10mm.
•
Provision and installation of floor coverings and environmental systems that limit or control static electricity build-up and discharge.
•
Provision of appropriate equipment for the remote support.
The customer is responsible for relocating the Kiosk equipment (check stand and components) to the final placement/installation position.
Keep the Diebold Nixdorf equipment area free from dust, smoke, lint, and other particles.
Restrict smoking, eating, and drinking around the equipment. Avoid locating the equipment near other machines that generate ink, carbon and paper dust particles.
NOTICE
Please note that Diebold Nixdorf will not take over any warranty/liability in case the technical and environmental requirements are not met.
10
8 Components
8.1 Exterior view
BEETLE/ iSCAN EASY eXpress+
1
2
3
5
8
9
6
4
7
1
2
Pole Light
Display 15“, 19“
6 Printer
7
EFT-holder with EFT*
(example only)
3
Swipe Card Reader or Waiter lock with
15“, 27” display
8
Waiter Lock (integrated, optional)
4 Lock 9 Article Surveillance System
5 Scanner
* It may be connected ETFs with 12V for max. current consumption of 1.1A (permanent).
11
BEETLE/ iSCAN EASY eXpress+
8.2 Interior view
8.3 15” and 19”
1
2
3
8
9
10
5
4 6
12
11
13
7
14
1 Pole Light (optional)
2
Swipe Card Reader or Waiter Lock
(only with 15“ Display)
3 Display 15“ orl 19“
8
9
PC
Power Supply
4 EFT*-holder
5 Scanner
10 Lock
11 Fan
12 Printer
6
Article Surveillance System (only with
Magellan 3xxx Vsi)
13 NFC (optional)
7 Waiter Lock integrated (optional) 14 Loud Speaker (optional)
* It may be connected ETFs with 12V for max. current consumption of 1.1A (permanent).
12
8.4 27”
BEETLE/ iSCAN EASY eXpress+
1
11
9
3
10
2
8
4
5
6
12
7
14
13
1 Pole Light (optional) 8 PC
2 Swipe Card Reader or Waiter Lock (optional) 9 Power Supply
3 Display 27“ 10 Lock
4 EFT*-holder
5 Scanner
11 Fan
12 Printer
6
Article Surveillance System (only with
Magellan 3xxx Vsi)
13 NFC (optional)
7 Waiter Lock integrated (optional) 14 Loud Speaker (optional)
* It may be connected ETFs with 12V for max. current consumption of 1.1A (permanent).
13
BEETLE/ iSCAN EASY eXpress+
9 Opening the device
Unlock the system with the key (siehe arrow).
Open the door to the left.
14
BEETLE/ iSCAN EASY eXpress+
10 Ventilating the system
Keep the device's ventilation openings uncovered to ensure adequate ventilation. This prevents the temperature increasing excessively.
Even if you plan to integrate the device, make sure to maintain the minimum distances stated below and ensure reliable ventilation and air extraction.
The direct ambient temperature of the system must not exceed 35 °C.
15
BEETLE/ iSCAN EASY eXpress+
Observe the specified minimum distances to ensure proper ventilation.
Always keep the ventilation slots free of obstruction to ensure adequate air circulation and avoid overheating.
45 mm
50mm
NOTICE
The device must not be installed near heat sources.
16
BEETLE/ iSCAN EASY eXpress+
11 Hand grips
NOTICE
Systems with a display size over 19" are equipped with handles on both sides for better handling during transport and installation due to their heavy weight.
Entfernen Sie nach der Installation die Handgriffe und bewahren Sie diese für weitere
Transporte auf.
17
BEETLE/ iSCAN EASY eXpress+
12 Installation in the table adapter
12.1 Requirements
NOTICE
The installation is under the responsibility of the customer.
The table adapter must be installed in a save manner at the table before the
BEETLE /iSCAN EASY eXpress+ may be installed.
12.2 Drill pattern dimensions for 15” and 19” for table adapter
Area for cable entry through the table
4x screws with shaft diameter max. 6mm use
Supporting surface on the table
-- FRONT SIDE--
18 dimensions in mm
BEETLE/ iSCAN EASY eXpress+
12.3 Drill pattern dimensions for 27” table adapter
19
BEETLE/ iSCAN EASY eXpress+
12.4 Installation 15” and 19” version
Insert the cables into the table adapter through an opening in the table top below the adapter, or route them into the table adapter through the cable outlet on the back of the adapter.
To be able to lay these cables later in the device, they must be placed in the left front area inside the table adapter.
Screw the table adapter to the table with 4 screws (shaft diameter 6mm) (see arrows).
Screw the top two screws into the table adapter up to half the length (see white arrows).
WARNING
The installation must be carried out by two persons.
Risk of crushing! Always wear safety gloves and safety shoes according
ISO 20345 with toe cap, closed heel area and energy absorbing heel area while transporting or assembling the device.
USA: Safety shoes with class 1 toe cap according ASTM F 2412 and ANSI
Z41.1 in its current versions.
Canada: Protection CSA code 1Pxxx.
20
BEETLE/ iSCAN EASY eXpress+
Then lift the device up and hang it into the upper catch hooks and screws in the table adapter
(see arrows).
First, insert the locked BEETLE /iSCAN EASY eXpress+ into the plate tabs of the table adapter.
21
BEETLE/ iSCAN EASY eXpress+
Unlock the device and open it.
Insert further 2 screws in the lower area (see arrows) and fasten the unit by tightening the four screws on the table adapter.
NOTICE
To connect the system, follow the instructions in chapter “Connecting the system”.
22
BEETLE/ iSCAN EASY eXpress+
12.5 Installation 27” version
NOTICE
Due to the high weight of the devices, the table adapter must be mounted with counter plates (see drawing). For this purpose, the screws supplied with the mounting kit must be used in accordance with the required length and the thickness of the plates.
23
BEETLE/ iSCAN EASY eXpress+
13 Installation: Hybrid (15” and 19” only)
With the hybrid tabletop version, an additional display and optional barcode scanner as well as an optional waiter lock can be installed on the BEETLE/ iSCAN EASY eXpress+.
It is possible to mount one of the displays BA90, BA92 or BA93.
The hybrid version ships with the scanner, waiter lock and display panel for display mounting installed. The corresponding display must be installed separately.
24
BEETLE/ iSCAN EASY eXpress+
13.1 Delivery
The scope of supply includes the pre-assembled table stand with hybrid function, a separate display, if necessary a mounted barcode scanner and possibly a mounted waiter lock according to the ordered options.
Display mounting plate
Display-/Scanner carrier
Waiter lock (optional)
Barcode scanner (optional)
Table stand
13.2 Dimensions and weight
Width 414 mm
Height
Depth
Weight
468 mm
351 mm
Approx. 8 kg (without components)
NOTICE
Further information about installation see chapter 11.2, 11.3.
25
BEETLE/ iSCAN EASY eXpress+
13.3 Display assembly
13.3.1 BA90
•
Loosen the four side M4x10 mounting screws (see arrows) and remove the display mounting plate from the display-/scanner carrier.
•
At first remove the cable cover from the display (see arrow).
26
BEETLE/ iSCAN EASY eXpress+
•
Mount the display mounting plate on the back of the display. The four M4x8 screws for this purpose are already pre-assembled in the display, or they are in the accessory pack of the display.
•
Thread the display cable with the bent plug through the opening of the display mounting plate. Insert and screw the plug to the display (see arrow).
•
Then insert the display cable through the opening at the bottom of the BEETLE/ iSCAN
EASY eXpress+.
•
Replace the display mounting plate with the display on the Display-/Scanner carrier and screw them laterally with the previously removed four M4x10 screws.
•
Insert and screw the straight plug of the display cable into the "Display 2" socket of the
ACO Kiosk Box (1).
Please observe the notes in the following chapter.
27
BEETLE/ iSCAN EASY eXpress+
13.3.2 BA92 und BA93
•
Loosen the four side M4x10 mounting screws (see arrows) and remove the display mounting plate from the Display-/Scanner carrier.
•
At first remove the cable cover from the display (see arrow).
•
Mount the display mounting plate on the back of the display. The four M4x8 screws for this purpose are already pre-assembled in the display, or they are in the accessory pack of the display. Corresponding to the marking, the BA92 is attached to the display mounting plate at the top (1) hole pattern, the BA93 to the bottom (2) hole pattern.
28
BEETLE/ iSCAN EASY eXpress+
2
1
•
Thread the display cable with the bent plug through the opening of the display mounting plate. Insert and screw the plug to the display (see arrow).
•
Then insert the display cable through the opening at the bottom of the BEETLE /iSCAN
EASY eXpress+.
•
Replace the display mounting plate with the display on the Display-/Scanner carrier and screw them laterally with the previously removed four M4x10 screws.
29
BEETLE/ iSCAN EASY eXpress+
•
Insert and screw the straight plug of the display cable into the "Display 2" socket of the
ACO Kiosk Box (1).
1
30
BEETLE/ iSCAN EASY eXpress+
Notice
Depending on the configuration of the EASY eXpress+, due to the many cables on the connection side of the ACO Kiosk Box, it could be very tight. It is recommended to swivel the box to fix the display cable.
•
To do this, pull the green handle down (2), slide the box to the left (3) and swing the box to the left (4). Insert and screw the plug of the display cable into the socket "Display 2" of the ACO-Kiosk Box (1).
3
1
1
4
2
•
Pull the green handle (2) downwards and push the box all the way to the left, then push it back to the right in the guide to its original position.
Please make sure that the power cord (1) above the box is not pinched!
1
•
Secure the display cable with cable ties to the previously installed harness of the
BEETLE/ iSCAN EASY eXpress+ base unit.
31
BEETLE/ iSCAN EASY eXpress+
13.4 Connection of Barcode Scanners
The ordered barcode scanner is already mounted in the hybrid order option and the corresponding cable is already connected to the scanner.
Thread the loose end of the scanner cable through the lower opening of the BEETLE/ iSCAN
EASY eXpress+ and plug the USB connector into the "USB-S" (1) port of the ACO Kiosk
Box.
1
•
Secure the cable with cable ties to the previously installed harness of the
BEETLE/ iSCAN EASY eXpress+ base unit.
•
To initialize the barcode scanner, use the corresponding barcode label.
32
BEETLE/ iSCAN EASY eXpress+
13.5 Barcode scanner initialization
13.5.1 Datalogic Magellan 3450VSi
For commissioning as a USB scanner to Diebold Nixdorf Service Objects, it must be initialized with the interface settings "USB OEM".
33
BEETLE/ iSCAN EASY eXpress+
13.5.2 Honeywell CF3680
The CF3680 scanner must be initialized with the 2D barcode listed below to meet the
Diebold Nixdorf requirements for use as a USB IBM OEM SurePos Table Top Scanner in kiosk systems.
The security code "Disable Command Bar Code" must then be initialized to prevent unauthorized persons from changing scanner properties in the field (see following page).
USB IBM OEM SurePos TableTop mode:
DEFALT
PAPSPT
SUFBK2990D
Reset device to default settings
Plug-and-Play code: enable SurePos Table Top Scanner
Suffix [CR]
SCNAIM4
DECMIR1
AZTENA0
CBRENA0
C93ENA0
I25ENA0
N25ENA0
Aimer Type 4 (Aimer and Illumination in alternate mode)
Mirror Mode for CF3680 disable Aztec disable Codabar disable Code93 disable Interleaved 2 of 5 disable NEC 2 of 5
UPC-A
UPC-E
EAN-13
EAN-8
CODE39
CODE 128
GS1-128 (former Code EAN 128)
PDF417
Datamatrix
QR-Code
Combined code:
DEFALT;PAPSPT;SUFBK2990D;SCNAIM4;DECMIR1;AZTENA0;CBRENA0;C93ENA0.
34
BEETLE/ iSCAN EASY eXpress+
Security Code
To prevent unauthorized persons from changing the properties of the CF3680 in the field by means of Programming Bar Codes (Command Bar Codes), this function must then be switched off after the initialization described on the previous page.
With the following barcode the possibility of programming the scanner with programming barcodes is switched off.
Disable Command Bar Code
MNUENA0.
To reactivate the Programming with Programming Codes function, scan the following barcode: (Note: this barcode is read by the CF3680 even if "Disable Command Bar Code" has been initialized).
Enable Command Bar Code
MNUENA1.
35
BEETLE/ iSCAN EASY eXpress+
13.6 Connection of waiter lock
When ordering the waiter lock in the BEETLE/ iSCAN EASY eXpress+ basic unit, it is already mounted and connected to the PC.
When ordering the waiter lock in the hybrid table stand, thread the free end of the cable through the lower opening of the BEETLE/ iSCAN EASY eXpress+ oder
Plug the plug into the "iButton X2" (1) connection of the ACO Kiosk Box.
1
Secure the cable with cable ties to the already laid harness of the BEETLE/ iSCAN EASY eXpress+ base unit.
36
BEETLE/ iSCAN EASY eXpress+
14 Installation: Wall Mounted Kiosk
14.1 Recommendation for wall mounting
WARNING
WARNING!
Risk of injury! Failure to observe the following installation instructions may result in serious injury if the unit falls over.
WARNING
Danger of damage and injury! Whenever work of any kind is done on the device, as well as when data cables are plugged and unplugged, the device must be completely disconnected from the line voltage.
WARNING
Danger of damage and injury! Check the quality of the wall first (appropriate and professional basic structure) and be sure the used screws and dowels can guarantee a secure holding of the system.
14.2 Hole pattern for wall mounting (dimensions in mm)
14.2.1 15” and 19” BEETLE /iScan EASY eXpress+
37
BEETLE/ iSCAN EASY eXpress+
Use four screws of max. 6mm in diameter and suitable dowels depending on the structural conditions on site. The 19” BEETLE /iScan EASY eXpress+ weighs approx. 30kg, while the
15” BEETLE /iScan EASY eXpress+ weighs approx. 28kg. The wall mount itself weighs approx. 3kg.
38
14.2.2 27” BEETLE /iScan EASY eXpress+
BEETLE/ iSCAN EASY eXpress+
NOTICE
Use the recommendet materials only (see next page)!
39
BEETLE/ iSCAN EASY eXpress+
14.3 Recommended materials
The suggested dowels and screws from the table are usable for the specified wall type. Due to variations of walls it is necessary to check the compatibility of the screws, dowels and the wall material including substructure on installation site. The wall and used fixation material must hold a weight of minimum 250 kg. For e.g. wood wool slab or insulated planking no secure wall-mounting is possible.
When wooden substructure is detected on one or more fixing points the hexagon head screw
DIN 571 – 6 x 50 can be used directly without a dowel, BUT to avoid cracks a pilot hole with
4mm diameter is needed then. dowel type
HM
6x37 S image screw type washe r type mounting torque
[Nm]
<5
Wall material
Gypsum plasterboard / chipboard
Wall/ planking thick-
Hole diameter
/ depth
[mm] ness
[mm]
6-15
12 / ≥45
HM
6x65 S
DUO-
POWER
8 x 40 hexagon head screw
ISO
4017 –
M6 x 50
– 5.6
*
hexagon head screw
ISO
4017 –
M6 x 75
– 5.6
*
hexagon head screw
DIN 571
– 6 x 50 washer
ISO
7094-
6,6x22 x2-100
HV washer
ISO
7094-
6,6x22 x2-100
HV washer
ISO
7094-
6,6x22 x2-100
HV
<5 n.a.
Gypsum plasterboard / chipboard
Concrete
(≥C20/25), solid brick, solid sandlime brick, aerated concrete
(≥PB4,
PP4), perforated sandlime brick,
Sepa Parpaing
17-34
12 / ≥71
≥60 8 / ≥50
* the included slotted screw has to be exchanged
40
BEETLE/ iSCAN EASY eXpress+
14.4 Installing the wall mount for 15” and 19” version
1. Drill the holes for the appropriate dowels as indicated in the hole pattern of the wall mount. Then screw the lower two screws approximately halfway into the dowels in the wall.
2. Clip the wall mount into the lower two screws through the keyholes and press downward to align all four holes in the wall mount to the dowels in the wall.
3. Screw in the two missing screws and tighten all four screws.
4. Slide all necessary cables
(power cable, LAN cable, etc.) through the opening in the wall mount and secure in the holes with the cable ties. Position the connectors in the front left-hand area so that they can be connected to the BEETLE
/iScan EASY eXpress+ in the next steps.
41
BEETLE/ iSCAN EASY eXpress+
5. Screw the upper two
M6x10 cheese-head screws halfway into the wall mount.
6.
Attention: Two people are needed to position the kiosk on the pillar.
First insert the closed BEE-
TLE /iSCAN EASY eXpress + below into the sheet metal tabs of the pillar adapter [1].
Then raise the BEETLE /iSCAN
EASY eXpress + and clip into the upper snap hooks and screws of the pillar adapter [2].
7. Open the BEETLE /iScan
EASY eXpress+ and insert the two missing M6x10 screws in the underside and tighten all four screws.
2
1
1
1
1
2
8. Please consult the Installation Guide for information on connecting the device.
42
BEETLE/ iSCAN EASY eXpress+
14.5 Inserting the system
4 positions for securing with screws with a diameter of 6mm
4 positions for securing with hooks; additional fixing with screws is necessary!
43
BEETLE/ iSCAN EASY eXpress+
15 Pillar mounting
15.1 Dimensions (in mm)
15.1.1 Optional base plate 15” and 19”
44
15.1.2 Optional base plate 27”
BEETLE/ iSCAN EASY eXpress+
45
BEETLE/ iSCAN EASY eXpress+
15.1.3 Pillar drill template
46
15.1.4 Example: Pillar mounting with 15”
BEETLE/ iSCAN EASY eXpress+
15.1.5 Example: Pillar mounting of 19” with optional basket shelf on both sides, status indicator, coupon box and base plate
47
BEETLE/ iSCAN EASY eXpress+
15.1.6 Example: Pillar mounting of 19” and optional scale platform
48
BEETLE/ iSCAN EASY eXpress+
15.2 Installation instructions: Self-Checkout on pillar
15.2.1 Self-Checkout with floor cabling
Installation including floor mounting must be carried out by a trained engineer after assessing and evaluating the structural conditions on site.
Materials required (depending on the substrate):
4x M10 anchor bolts
4x DIN 933 M10x60-8.8 hexagon bolts
4x 10.5x2.0 washers
1. Raise the front panel and remove it frontward.
2. Remove the safety screw [1], then raise the rear cover and remove this [2].
2
1
49
BEETLE/ iSCAN EASY eXpress+
3.
Position the pillar above the floor outlet so that the cables can pass through the hole in the center of the base plate.
The pillar must always have a solid base.
4. Mark the four holes as drilling points.
Do not mark any drilling points near the cable feed!
Attention: The kiosk must be screwed tightly to the floor so that it cannot tilt over.
Drill the four holes in the floor using a
12mm drill and install the anchor bolt.
The drill holes must be 80 mm deep.
5. Push all required cables through the opening in the base plate.
Position the pillar with the holes precisely over the drill holes with the anchor bolts.
Secure the pillar using the hexagon nuts.
50
6. Leave the cable lying on the base plate.
BEETLE/ iSCAN EASY eXpress+
7. Screw the two M6x10 screws in halfway.
Attention: Two people are needed to position the kiosk on the pillar.
8. First insert the closed BEETLE
/iSCAN EASY eXpress + below into the sheet metal tabs of the pillar adapter [1].
Now raise the
BEETLE /iSCAN EASY eXpress + and clip into the upper snap hooks and screws of the pillar adapter [2].
2
1
1
1
1
2
51
BEETLE/ iSCAN EASY eXpress+
9. Unlock the device and open the door. Insert two more
M6x10 screws (see arrows) in the lower area and secure the device by tightening all four screws on the pillar adapter.
10. Insert the cable into the BEE-
TLE /iSCAN EASY eXpress + housing and secure with cable ties in free drill holes on the pillar from the inside.
For more information about connecting the cables, see the
BEETLE /iSCAN EASY-eXpress + Installation Guide on the
Diebold Nixdorf website.
52
11. Mount the optional components, such as basket shelf or scale platform, in accordance with the configuration ordered; see adjacent chapter details.
14.2.4 Basket shelf at front
14.2.5 Basket shelf at side
14.2.6 Security scale at front
14.2.7 Security scale at side
14.2.8 Coupon box
14.2.9 Signal indicator
14.2.10 Coupon printer shelf
12. Insert the rear panel and secure by screwing in.
BEETLE/ iSCAN EASY eXpress+
13. Unlock the BEETLE /iSCAN
EASY eXpress + and open the door.
Now insert the front cover.
Close and lock the BEETLE
/iSCAN EASY eXpress + .
53
BEETLE/ iSCAN EASY eXpress+
15.2.2 Self-Checkout with floor cabling and optional base plate
Installation including floor mounting must be carried out by a trained engineer after assessing and evaluating the structural conditions on site.
1. Follow steps 1-2 in Section
14.2.1
2.
Position the base plate above the floor outlet so that the cables can pass through the hole in the center of the base plate.
The pillar must always have a solid base.
3. Position the pillar on the base plate and secure it using 4 M8x12 screws.
• Pull all required cables through the opening into the interior of the pillar.
• Follow steps 6-13 in Section 14.2.1.
54
BEETLE/ iSCAN EASY eXpress+
15.2.3 Self-Checkout with cabling “on the floor”
1.
2. Pull all required cables through the opening into the interior of the pillar.
Follow steps 1-4 in Section 14.2.1
3. Follow steps 6-13 in Section
14.2.1
15.2.4 Installing the basket shelf at the front side
1. To install the basket shelf at the front at the standard height (535 mm), clip the two angle brackets into the grid of the pillar so that the upper hook is located in the 12th opening from below.
55
BEETLE/ iSCAN EASY eXpress+
2. Insert the two safety plates from the inside as shown in the diagram alongside [1] and secure each of these from the outside using two
M6x10 cheese head screws
[2].
3. Place the basket shelf on the angle brackets and push these toward the rear until the shoulder screw on the right-hand side submerges into the key contour [1]. Now pull the shelf forward again right up to the key contour
[2]. The shelf is now secured from falling down during the further course of installation.
View from below
2
1
2
1
2
1
2
1
2
2
4. Finally, screw in four M5x10 cheese head screws from below into the basket shelf.
View from below
56
BEETLE/ iSCAN EASY eXpress+
15.2.5 Installing the basket shelf at side
Installation of the basket shelf on the right is described here by way of example, the left basket shelf is secured accordingly on the left-hand side.
1. To install the side basket shelf at the standard height (535 mm), clip the shelf into the mounting grid so that the upper hook is located in the 12th opening from below.
2
1
2. Insert the two safety plates from the inside as shown in the diagram alongside [1] and secure each of these from the outside using two M6x10 cheese head screws [2].
2
2
15.2.6 Installing the security scale at front
1. To install the front security scale at the standard height (535 mm), clip the two angle brackets into the grid of the pillar so that the upper hook is located in the 12th opening from below.
2
1
2
1
57
BEETLE/ iSCAN EASY eXpress+
2. Insert the two safety plates from the inside as shown in the diagram alongside [1] and secure each of these from the outside using two M6x10 cheese head screws [2].
3. First place the scale on the angle brackets without load plate and push these to the rear until the shoulder screw on the right side submerges into the key contour
[1]. Now pull the scale forward again right up to the key contour
[2]. The scale is now secured from falling down during the further course of installation.
View from below.
2
1
2
1
2
2
1
2
1
2
4. Finally, screw in four M5x10 cheese head screws from below into the security scale.
View from below.
58
5. Run the cable for the scale controller upward in the rear area of the pillar and secure it from the outside in a free drill hole using cable ties.
BEETLE/ iSCAN EASY eXpress+
6. Now feed the cable to the BEE-
TLE /iSCAN EASY eXpress + in the top area.
7. Place the load plate on the scale.
59
BEETLE/ iSCAN EASY eXpress+
15.2.7 Installing the security scale at side
The installation of the security scale on the right is described here by way of example, the left security scale is secured accordingly on the left-hand side.
1. To install the side security scale at the standard height (535 mm), first clip the scale without the load plate into the mounting grid so that the upper hook is mounted in the
12th opening.
2
1
1. Insert the two safety plates from the inside as shown in the diagram alongside [1] and secure each of these from the outside using two M6x10 cheese head screws [2].
2
2
2
1
1
2
2
2. Run the cable for the scale controller upward in the rear area of the pillar and secure it in a free drill hole using cable ties.
60
3. Now feed the cable to the
BEETLE /iSCAN EASY eXpress + in the top area.
BEETLE/ iSCAN EASY eXpress+
4. Place the load plate on the scale.
15.2.8 Installing the coupon box
1. Insert the mounting frame into the pillar so that the lower fixing hole corresponds to the bottom drill hole in the perforated grid of the mounting pillar.
61
BEETLE/ iSCAN EASY eXpress+
2. Now screw in the four M6x10 cheese head screws on both sides from the outside into the corresponding threaded drill holes.
3. Secure the cable in free drill holes using cable ties and feed the cable to the BEETLE /iSCAN EASY eXpress + .
62
4. Insert the coupon box [1], close [2] and finish [3].
3
BEETLE/ iSCAN EASY eXpress+
2
1
63
BEETLE/ iSCAN EASY eXpress+
15.2.9 Installation sensormatic controller
1. Remove the rubber feet from the controller and fix the Sensormatic
Controller [1] with 4 screws M4x8
[2] to the controller mounting plate
[3].
2
3
1
2. The two screws M4x14 [1] are pre-assembled in the retaining plate. Screw in the screws only 3 turns.
2
1
3. Now hang the retaining plate with the controller on both sides into the lower openings [1] of the support column.
1
1
1
64
4. Insert the lug of the retaining plate
[1] between the base plate [2] and the rear wall of the pedestal.
(Illustration without rear panel)
BEETLE/ iSCAN EASY eXpress+
1
2
1
5. Insert the two locking plates [1] as shown in the adjacent illustration on the left and right and fix them from the outside with two M6x10 cylinder head screws [2] each.
6. Screw the two pre-assembled screws M4x14 [1] against the rear panel until the controller is firmly seated.
2
1
2
1
1
65
BEETLE/ iSCAN EASY eXpress+
7. Cabling
Use the supplied cables to connect the
Sensormatic Controller.
- 01750332222 cable RS232 ADT
AMB9010IPS 2.5m
- 7128500816 Power cable Y-Connector
0.4m
- 5645207616 Power cable G-G 0.7m
Insert the female connector of cable
5645207616 from below into the EASY eXpress+ and plug it into the fixed IEC cable.
Connect the other end of the cable to one of the two branches of the Y-cable
(7128500816).
Plug the other similar plug of the Y-cable
(7128500816) into the cold device input socket of the controller marked B in the picture.
Plug the RJ plug of the data cable
(01750332222) coming from the EASY eXpress+ into the RJ input socket marked
F in the figure.
Plug the connector of the antenna cable also coming from the EASY eX-press+ into socket H.
The mains connection of the entire system is made with the included mains cable, which is plugged into the free plug of the Y-cable.
Use cable ties to fasten the cables to free holes in the hole grid inside the column.
See also the block diagram in chapte r 23.
Sensormatic Controllers AMB-9010-IPS
01750332222
EASY eXpress+ System
Pole or customer furniture
5645207616
66
7128500816
8. Set the cover into place. Close the door and lock it.
BEETLE/ iSCAN EASY eXpress+
67
BEETLE/ iSCAN EASY eXpress+
15.2.10 Installing the signal indicator
1. Screw in two M4x6 round head screws halfway into the lower two drill holes on the rear of the pillar.
2. Place the base plate on the two screws and slide the base down to the floor [1]. Now tighten the screws [2].
3. Insert the rear panel and secure with a safety screw.
1
2 2
68
4. Insert the mounting bracket through the upper opening in the rear panel and screw tightly using two M4x6 round head screws.
5. Remove the aluminum profile without drill holes (see markings) in the direction of the arrows.
6. Likewise separate the other aluminum profiles (remove in the direction of the arrows).
7. Connect the aluminum profiles without gaps using four M4x6 round head screws.
BEETLE/ iSCAN EASY eXpress+
8. Place the connected aluminum profile with status indicator on the base plate and screw tightly to the mounting bracket using two M4x6 screws.
9. Feed the cable from the status indicator down through the opening in the base plate into the pillar.
69
BEETLE/ iSCAN EASY eXpress+
10. Position the outer aluminum profile and lock in place.
11. Now secure the cable from the status indicator cable inside the pillar to a free drill hole in the perforated grid using cable ties and feed through to the BEETLE
/iSCAN EASY eXpress + .
70
BEETLE/ iSCAN EASY eXpress+
16 Connecting the System
The BEETLE /iSCAN EASY eXpress will be delivered with a card board. Unwrap the device.
WARNING
Risk of crushing! Always wear safety gloves and safety shoes according
ISO 20345 with toe cap, closed heel area and energy absorbing heel area while transporting or assembling the device.
USA: Safety shoes with class 1 toe cap according ASTM F 2412 and ANSI
Z41.1 in its current versions.
Canada: Protection CSA code 1Pxxx.
Open the device.
Lead the cables through the hole at the back side of the device.
71
BEETLE/ iSCAN EASY eXpress+
Plug the cable at the power supply (see arrow).
Plug the LAN-cable for the EFT at the EFT-distributor.
Power cablel
LAN-cable EFT
NOTICE
For reasons of manipulation security, the LAN cables for payment transactions should be color-matched to the cables for data traffic.
72
Plug the LAN-cable at the central unit.
PC
BEETLE/ iSCAN EASY eXpress+
Close the door.
73
BEETLE/ iSCAN EASY eXpress+
17 Removing the protection foil at the
Display and Front surface
Remove the protection foil from the display and the front surfaces after the installation process.
74
BEETLE/ iSCAN EASY eXpress+
18 Installation in general
18.1 EFT (Electronic-Funds-Transfer)-Terminal
Power down the system. Open the device (Section "Opening the BEETLE /iSCAN EASY eXpress) and separate completely the system from the mains voltage.
NOTICE
Various, customer-specific EFTs are used.
Here in the example it is the IPP350.
Remove the two screws (see arrows).
Remove the bracket, including the support plate. Loosen the two screws.
75
BEETLE/ iSCAN EASY eXpress+
EFT-support plate
EFT-bracket
Screw the support plate at your EFT terminal, here for example an IPP350 EFT.
Hook the EFT support plate into the EFT mount at the bottom.
76
Connect both with a supplied locking screw.
Place the two nuts and tighten them.
BEETLE/ iSCAN EASY eXpress+
77
BEETLE/ iSCAN EASY eXpress+
Thread the connection cable through the opening and attach the EFT incl. Bracket.
Screw the EFT incl. Bracket / support plate to the housing.
Fold the EFT incl. Bracket into the horizontal position.
Secure the cable with two cable ties.
78
BEETLE/ iSCAN EASY eXpress+
Route the cable as shown in the figure to the BEETLE / Kiosk and plug it into the provided
COM port.
Secure the cable once again with a cable tie.
79
BEETLE/ iSCAN EASY eXpress+
If the connector is a LAN or USB plug, you connect it to the corresponding socket (see arrows) on the distribution board of the EFT.
The connection cable is to be installed similar to the one shown on the previous page.
Plug the power cable to the BEETLE / Kiosk, start the system and close the BEETLE /iSCAN
EASY eXpress.
80
18.2 EFT ICT 220/250
BEETLE/ iSCAN EASY eXpress+
The EFT fastening is removed from the EFT recess with the hinge (2x screw M5 Torx TX25) and the support plate is detached from the holder underneath (2x nut M4 SW7 and 1x M3 TX
10). These fixing screws are required again for installation.
81
BEETLE/ iSCAN EASY eXpress+
For the ICT 220/250, a two-piece EFT support plate is used.
The upper part, the closure, is lifted off.
82
Then the ICT 220/250 is inserted into the lower shell.
BEETLE/ iSCAN EASY eXpress+
Then the ICT 220/250 is inserted into the lower shell.
The two parts are finally screwed to the carrying plate with the 2xM4 nuts and secured with the M3x6 Torx screw. This assembly can then be reinstalled in the EFT recess in the system
(2x M5).
83
BEETLE/ iSCAN EASY eXpress+
19 EFT Worldline Valina
EFT mounting plate
Demount the EFT mounting plate at the internal fixing points internal fixing nuts
84
BEETLE/ iSCAN EASY eXpress+
Remove the EFT mounting plate from the EASY eXpress + and unscrew the transportation cover at the 4 fastening screws backside
EFT mounting plate without transportation cover
85
BEETLE/ iSCAN EASY eXpress+
EASY eXpress + after demounting EFT mounting plate
Now take the accessory kit with the privacy shield and the 4 EFT mounting screws M4x20
86
BEETLE/ iSCAN EASY eXpress+
…and fix the privacy shield with 3 fastening nuts to the EFT mouinting plate (see picture next page).
87
BEETLE/ iSCAN EASY eXpress+
Put the EFT Wordline Valina in the mounting plate and fix it with the 4 M4x20 screws and washers
Insert the mounting plate with the mounted EFT Wordline Valina into the door by meeting the door fixing points
Fix the mounting plate with the EFT Worldline Valina to the door fixing points with 3 M4 nuts.
88
BEETLE/ iSCAN EASY eXpress+
EASY eXpress + with mounted EFT Wordline Valina
89
BEETLE/ iSCAN EASY eXpress+
20 EFT Verifone P400
Uninstall the EFT fastening including the EFT support plate together with the hinge from the
EFT recess of the Easy-eXpress + (2x M5 TX25 screw). Loosen the EFT support plate from the holder underneath (2x nut M4 SW7 and 1x screw M3 TX 10 - these fixing screws are needed again for installation).
EFT support plate for Verifone P400
90
BEETLE/ iSCAN EASY eXpress+
Pass the included EFT connection cable through the door opening and connect it to the
Verifone P400.
Remove the cover and insert the plug.
Replace the cover.
91
BEETLE/ iSCAN EASY eXpress+
Insert the Verifone P400 into the EFT mounting plate and fasten it with two screws M3x6.
Then the EFT support plate is screwed together with the EFT again with the EFT fastening and secured. Use 2x nut M4 and 1x screw M3.
92
BEETLE/ iSCAN EASY eXpress+
The assembly can then be remounted with the hinge in the EFT recess of the system using the two M5 screws.
Fasten the cable to the EFT support plate with 2 cable ties.
The cable must not be crushed in any of the possible positions of the EFT.
93
BEETLE/ iSCAN EASY eXpress+
Fix the cable to the wiring harness with two additional cable ties.
Fasten the cable regularly with additional cable ties in the further course of the wiring harness.
94
BEETLE/ iSCAN EASY eXpress+
The power supply cable (01750254745) is pre-installed and plugged into the PC.
Plug the DC voltage plug into the EFT connection box.
95
BEETLE/ iSCAN EASY eXpress+
Place the junction box in the system.
Further connection options are located on the back of the connection box.
96
BEETLE/ iSCAN EASY eXpress+
5. EFT DESK3500
Shut down the kiosk and disconnect the plug from the socket of the house installation.
Loosen the M4 nut of the cover plate.
Remove the cover.
97
BEETLE/ iSCAN EASY eXpress+
Plug the Y cable.
Plug the cable (01750344225) at the Y cable.
98
BEETLE/ iSCAN EASY eXpress+
Plug the cable (01750344225) at the Ingenico Desk3500 power supply and put it into the desk stand.
Wire the cable connected to the power supply unit following the path of the existing cable harness and fix it with cable ties.
99
BEETLE/ iSCAN EASY eXpress+
Fix the cable at regular intervals with cable ties.
Move the cable through the opening at the EFT holder.
100
Plug the cable.
BEETLE/ iSCAN EASY eXpress+
Stow the excess length in the cap, put on the cover plate and screw it with the M4 nut.
Lay the data cable along the same path as the power cable.
Tighten the cable ties, cut them off.
Close the door carefully, checking that the cable is not disconnected.
101
BEETLE/ iSCAN EASY eXpress+
21 Cleaning Instructions
21.1 General Information
Always turn off the system before cleaning.
The glass surface of your Touch Screen and the scanner window should be cleaned with a mild, abrasive-free, commercially available glass cleaning product.
NOTICE
Wrong maintenance may cause damages to the screen, which are not covered by warranty.
All pH neutral materials (pH 6 to 8) are good for cleaning. Cleaners with pH values 9 to 10 are not recommended. Cleaning with water and isopropyl alcohol is possible as well.
Do not use solvents containing acetic acid.
Use a soft, fine-meshed cloth to clean the surface. Dampen the cloth slightly and then clean the screen and the scanner window.
Clean the housing with a vacuum cleaner or soft cloth.
21.2 Maintenance and Service
The system must be disconnected from the mains before working on components and modules that are electrostatically charged.
21.3 Housing
Clean housing with a vacuum cleaner or duster.
102
BEETLE/ iSCAN EASY eXpress+
21.4 Approved Cleaning Materials
The items listed below can be ordered from Diebold Nixdorf branch office or your Diebold
Nixdorf sales partner.
Product Name Order
Number
Explanations
Cleaning wipes
TFT, Screen Clean wipes
01750097332 For all plastic and metal surfaces, not for
TFT screens, dispenser box with 100 wet cloths
01750097334 For TFT/LCD Screens, does not contain alcohol, non-flammable, 50 cloths wet and 50 cloths dry
Air Duster 400g 01750108425 Non-flammable
Cleaning cloth with Isopropyl 01750104065 100 cloths with isopropyl
Cleaning Card for Hybrid
Card reader
Cleaning Card for POS
01750016388 Wet cleaning card for all chip- and hybrid card readers
01750177183 Cleaning Card for MSR and Chip Card
Reader
Chipkontakt-Reinigungskarte 01750111611 Cleaning Card for EFT
Please note the manufacturer’s specifications on the packaging and on the information sheet included in the packaging. The product may be damaged or soiled if materials are used that are not approved or if they are used improperly.
103
BEETLE/ iSCAN EASY eXpress+
22 Technical data
22.1 System
Mains input voltage with sensormatic
Power consumption
Power typical
Power max.
Power standby
Weight 15” Version
100-240 V~ / 60-50Hz
100-120 V~ / 200-240V~ ; 60/50Hz
1.4-0.7A ca. 55W ca. 87W ca. 1.5W ca. 28 Kg
Weight 19” Version
Weight 22“ ca. 30 kg ca. 33 kg
Weight 27“
Weight 32“ ca. 37 kg ca. 40 kg
Weight Hybridoption without components ca. 8 kg
104
BEETLE/ iSCAN EASY eXpress+
Operating temperature
Ambient temperature:
Humidity:
Temperature change:
5° C – 35° C
5% r.h. (1 g/m 3 ) – 85% r.h. (25 g/m 3 )
Barometric pressure:
0.5 K/min (max. 7.5K/30 min)
70 kPa – 106 kPa
(70kPa corresponds to an installation at approximately 2000 meters above sea level)
Installation environments with long periods of sunshine should be avoided
Storage conditions
Ambient temperature:
Humidity:
Temperature change:
Transport conditions
Ambient temperature:
Humidity:
Temperature change:
5° C – 40° C
5% r.h. (1 g/m 3 ) – 85% r.h. (25 g/m
0.5 K/min (max. 7.5K/30 min)
-25 °C – 60° C
-25° C / 25° C
3 ) 0.5 K/min
15% r.h. (1 g/m 3 ) – 98% r.h. (32 g/m 3 )
22.2 PC
SSD
CPU
Graphic Adapter
128 GB
Intel i5-4570TE
VGA, resolution max.
1920x2000 Pixel @ 60 Hz
105
BEETLE/ iSCAN EASY eXpress+
22.3 Display 15”
Dimensions
Frequencies
Resolutions
Dot/pixel size
Reading angle
Vertical
Horizontal
Brightness
Backlighting
Touch Technology
Contrast
Reaktion time
Diagonals 15" (38.1 cm) TFT Ratio 4:3
Max. resolution 1024 x 768
Screen housing 337.4 x 265.4 x 44.3 mm
Screen area 304.1 x 228.1 mm
Horizontal (KHz) Typ. 48.3
Vertical (Hz) Typ. 60
Horizontal
Vertical
Color depth
1024 pixels
768 pixels
Up to 16.2 million
Approx. 0.297 mm x 0.297 mm
Typically 160 degrees; min. 140 degrees
Typically 140 degrees; min. 120 degrees
Typically 250 cd/m²
Twin lamps CCFL, inverter
10 points Projective Capacitive
700:1
25ms (typ)
106
BEETLE/ iSCAN EASY eXpress+
22.4 Display 19”
Dimensions
Frequencies
Resolutions
Dot/pixel size
Reading angle
Vertical
Horizontal
Brightness
Backlighting
Touch Technology
Contrast
Reaktion time
Diagonals 19“ (48.3 cm) TFT – Ratio 5:4
Max. resolution 1280 x 1024
Screen housing 373 x 301 mm
Screen area
Vertikal (Hz)
Horizontal typ. 48,3 typ. 60
1280 Pixel
Vertical
Color depth
1024 Pixel
Up to 16,2 Mio. ca. 0,294 mm x 0,294 mm typ. 160 ° typ. 170 ° typ. 225 cd/m²
Twin lamps CCFL, Inverter
10 points Projective Capacitive
1000:1
5ms (typ)
107
BEETLE/ iSCAN EASY eXpress+
22.5 Display 27”
Native Display resolution 1920 x 1080
3000:1 Contrast
Color deepness 16.7M
Brightness (without Touch) 300 cd/m 2
Brightness (with Touch) 270 cd/m 2
Active Area
Viewing angle
Video Input
Power consumption
Plug & Play
Supported resolutions
597.9 (H) x 336.3 (V) mm
178° (H) / 178° (V)
VGA (analog) / DP und HDMI (digital)
30W (On-Mode) / 3W standby / 2W Soft-Off
DDC 2B kompatibel
1920 x 1080 (60Hz)
1680 x 1050 (60Hz)
1440 x 900 (60/75Hz)
1280 x 1024 (60/70/75Hz)
1024 x 768 (60/70/75Hz)
800 x 600 (60/70/72/75Hz)
640 x 470 (60/66/70/72/75Hz)
720 x 400 (70Hz)
Touch Screen Technology Projective Capacitive (10-Points)
108
BEETLE/ iSCAN EASY eXpress+
22.6 Printer TH230+
Technology High-speed thermal printer
Resolution
Printing speed
Cutter
Paper transport
Control functions
Optional
Housing color
Features
Statistical data
Reliability
Graphics function
Paper width
8 dots/mm (203 dpi)
Mono color: 220 mm/s,
Two colors: 110 mm/s
Draft mode up to 300 mm/s (reduced intensity)
Material: hardened steel,
Full cutting speed: < 300ms
Forwards; to utilize the entire capacity of the paper > after cutting: up to 12mm backwards (approx. 3.5 lines at 7.52 lpi)
Print head temperature control with adjustment of the print speed
Near end paper control and out of paper control
Error message for paper cutter
Printer cover open/closed
Self-test with printout
Paper width 57.5mm,
Printing width = 51mm = 408 dots
Light gray or black
Simple replacement of paper roll: Optional two-color printing with special paper (100mm/s)
'Paper almost empty' message: can be defined by the user
Total number of dots
Total number of line feeds
Total number of cuts
Max. head temperature
Paper jam counter
Error counter for cutter
Error counter for thermistor
Error counter for high voltage/low voltage
Number of firmware updates
Switch-on time in hours
Switch-on counter
55 million lines
3 million cuts at 55g/m²
150km at 12.5% print density
The TH230 is fully graphic-compliant.
79.5mm - 80mm
109
BEETLE/ iSCAN EASY eXpress+
Paper weight
Paper thickness
Thermal coating
Paper roll
Outer diameter
Width of paper roll
Length of paper
Core size
55g/m² ± 5 g/m²
0.055mm – 0.1mm
Rear side of paper
90mm max.
80.3mm max.
~100m
Core diameter 10mm +2mm
Wall thickness of core: max. 2mm ± 0.3mm;
End of paper not glued to core.
Length of paper fold at core: 35mm
72mm = 576 dots Print width
22.7 TH250
Interfaces
Memory/Firmware
Energy-Savings
Resident character sets
Interfaces vary according to specific configuration: USB,
USB/RS232 (25 pin), USB/Ethernet, or PoweredUSB
8 MB flash memory, History EEROM, 4k buffer
Option to configure printer to enter low-power (1 watt) idle state if no data is received after user-specified number of minutes.
PC code pages 437 (US), 720 (Arabic), 737 (Greek), 775
(Baltic), 850 (Multilingual), 852 (Latin II), 857 (Turkish), 858 (with
Eurosymbol), 860 (Portuguese), 862 (Hebrew), 863 (French
Canadian), 864 (Arabic), 865 (Nordic), 866 (Cyrillic), 874 (Thai),
1250 (Windows Central Europe), 1251 (Windows Cyrillic), 1252
(Windows Latin I), 1254 (Windows Turkish), 1255
(Windows Hebrew), 1256 (Windows Arabic), 1257 (Windows
Baltic), 28591 (Windows Latin 1), 28592 (Windows Latin 2),
28594 (Windows Baltic), 28596 (Windows Arabic), 28599
(Windows Turkish), 28605 (Windows Latin 9), Katakana, and
KZ_1048 (Kazakh)
Downloadable Fonts Code pages 932 (Kanji), 949 (Korean), 936 (Simplified Chinese) and 950 (Traditional Chinese).
Integrated bar codes Code 39, Code 93, Code 128, UPC-A, UPC-E, JAN8 (EAN),
JAN13 (EAN), Interleaved 2 of 5, Codabar, Code 128, PDF-417
(two-dimensional), Code 128 extended, GS1 Databar, QR code, and Datamatrix
Print Monochrome or two-color print in either 44 (standard) or 56
(compressed) columns on 80 mm wide thermal paper
110
BEETLE/ iSCAN EASY eXpress+
Paper path
Print resolution
Speed
Options for 58 mm and 60 mm wide paper are also available
58 mm, 60 mm, 80.0 mm paper path width models
8-dots/mm (203 dpi)
Up to 350 mm/second throughput (monochrome); up to 150 mm/second throughput (two-color).
22.8 Epson TM-T88VI
Printing method
Roll paper Paper width
Thermal line printing
80 mm paper width setting: 79.5 mm ± 0.5 mm
{3.13" ± 0.02"}
58 mm paper width setting: 57.5 mm ± 0.5 mm
{2.26" ± 0.02"}
Maximum 83 mm {3.27"} External diameter
Core internal diameter 12 mm {0.47"}
Interface
Supply voltage
Current consumption
AC power consumption
(100 V to 230 V/50 to 60 Hz)
Overall dimensions
Weight (mass)
Core external diameter 18 mm {0.71"}
Serial: RS-232 Parallel: IEEE1284
Ethernet: 10BASE-T/100BASE-TX
Wireless LAN: Connect the optional Wireless LAN unit to the USB connector.
Bluetooth ®: Bluetooth 3.0 (EDR supported) USB:
USB 2.0 Full-speed (12 Mbps)
USB PlusPower: Full-speed (12 Mbps)
DC + 24 V ± 7%
1.8 A
Operating: Approx. 30.8 W
Standby: Approx. 0.8 W
148 × 145 × 195 mm {5.83 × 5.71 × 7.68"}
(H × W × D)
Approx. 1.6 kg {3.5 lb}
111
BEETLE/ iSCAN EASY eXpress+
22.9 Custom printer
RS232 serial connector
USB connector
Receive buffer
Flash memory
RAM memory
Resolution
Printing method
Printing speed
Paper width
With “shutter” device (optional)
Paper weight
External roll diameter
External roll core diameter from 9600 to 115 200 bps
12 Mbit/s (USB 2.0 full speed)
2 Kbytes
1 Mbytes internal + 4 Mbytes external (of which 1 Mbytes available)
128 Kbytes internal + 8 Mbytes external
203 dpi (8 dot/mm)
Thermal, ixed head
High Quality = 100 mm/s
Normal = 150 mm/s High Speed = 200 mm/s
Without paper roll holder support from 50 mm to 82.5 mm
With paper roll holder support (optional) from 60 mm to 82.5 mm from 60 mm to 82.5 mm from 60 g/m2 to 110 g/m2 max. 150 mm
25 mm
112
BEETLE/ iSCAN EASY eXpress+
22.10 Magellan 3450VSi
Read performance
Resolution (maximum)
Image capture
Image sensor
Read indicators
5 mil
Graphics format: BMP, JPEG
1280 x 1024
Beeper (adjustable sound and volume), Good Read LED, transmission confirmation
14.0 cm / 5.5 in Read height
Read rate (maximum)
Reading angle
Light source
Dimensions
Weight
Barcode types
1D barcode
39 million pixels per second
Pitch +/- 65 °; roll (tilt): 0-360 °; skew (yaw): +/- 75 °
Different diffused LED's, alignment and wavelength for high user comfort,
LED Class IEC 62471 and IEC62471 Lighting - EXEMPT
GROUP
14.2 x 15.2 x 8.2 cm (5.6 x 6.0 x 3.2 in)
0.6 kg (1.3 lb)
Automatic recognition of all standard linear codes and linear GS1 DataBar TM codes
2D barcode
Stacked codes
Aztec Code, Data Matrix (ECC200 only), MaxiCode, QR code
GS1 DataBar Composites, GS1 DataBar Expanded
Stacked, GS1 DataBar Stacked; GS1 DataBar Stacked
Omnidirectional;
MicroPDF 417, PDF417
Digital watermarks (optional) Digimarc Barcode/GS1 DW Code capture
113
BEETLE/ iSCAN EASY eXpress+
22.11 Scanner Magellan 3200VSi
Reading features
Resolution max.
Image aquisition
Image sensor
Read indicators
Read height
Read rate (maximum)
Read angle
Light source
Barcode-Arten
1D Barcode
2D Barcode
Stapelcodes
5 mil
Graphic format: BMP, JPEG
1280 x 1024
Beeper, (adjustable sound and volume), Good Read LED, transmission confirmation Good Read LED
14,0 cm /5,5 in
39 Mill. Pixel/sec.
Pitch +/- 65 °; Roll (Tilt): 0-360 °; Skew (Yaw): +/- 75 °
Lightning: several 625nm LEDs,
Laser Klasse 1 IEC 62471 EXEMPT GROUP
Automated detection of all standard linear codes and linear
GS1 DataBar TM Codes
Aztec Code, Data Matrix (ECC200nur), Maxicode, QR-
Code
GS! DataBar Composites, GS1 DataBar Expanded
Stacked, GS1 DataBar Stacked; GS1 DataBar Stacked
Omnidirectional;
MicroPDF 417, PDF417
114
BEETLE/ iSCAN EASY eXpress+
22.12 Scanner ZEBRA MS4717 CONE
Illumination red LED
Ambient light 0 Lux to 107,369 Lux
(0 Footcandle to 10.000 Footcandle)
1280 px x 800 px Resolution
Filed of View
Skew, Pitch and Roll horizontal: 42°, vertical: 28°
± 60°, ± 60°, ± 360°
Symbology Decode
Capability
Decode ranges
Symbol
5mil Code39
All major 1D- and 2D Barcodes
Near distance
(mm [Inch])
0 [0]
Far distance
(mm [Inch])
239 [9,4]
20mil Code39
13mil 100 % UPC
5mil Code128
10mil Data Matrix
20mil QR
0 [0]
0 [0]
0 [0]
0 [0]
0 [0]
488 [19,2]
437 [17,2]
196 [7,7]
203 [8,0]
345 [13,6]
115
BEETLE/ iSCAN EASY eXpress+
22.13 Scanner Honeywell CF3680
Illumination
Scan pattern
Scan angle horizontal: 37.8° (±1 .0°), vertical: 28.8° (±1.0°)
Decode capability All 1D- and 2D-barodes
Light level 0 lux to 100,00 lux
[0 foot-candles to 9,290 foot-candles]
Table Symbologies
Symbol Near distance
(mm [inch])
Far distance
(mm [inch])
Depth of field
(mm [inch])
10MILC39 0 [0] 174 [6,7] 174 [6,7]
15MILC39 0 [0]
100 %UPC-A 0 [0]
0 [0] 15MIL
PDF417
15MILDM 0 [0]
20MILQR 0 [0]
White LED
Area image (640 px x 480 px array}
259 [10,21]
210 [8,21]
187 [7,31]
87 [3,41]
150 (5,9]
259 [10,2]
210 [8,2]
187 [7,3]
87 [3,4]
150 (5,9]
22.14 RFID/NFC Modul
Provided Standards
RF-frequency
Firmware-Updates
Middleware
Operating system
ISO/IEC 15693
ISO/IEC 14443 Type A
ISO/IEC 14443 Type B
13.56 MHz
Firmware upgradable via DFU interface
JavaPOS 1.13
Windows 7, Linux
116
BEETLE/ iSCAN EASY eXpress+
23 Dimensions (mm)
23.1 Orientation and vertical mounting
The BEETLE /iSCAN EASY eXpress + may be installed vertically or tilted at an angle of up to
23° (15” and 19”) and 5° (bigger 22”) from the vertical.
NOTICE
Danger owing to ingress of liquids!
In case of vertical assembly in a restaurant environment, a suitable mechanism must be used to ensure that no beverages can be placed on the device.
Ingress of liquids can damage the device irreparably.
117
BEETLE/ iSCAN EASY eXpress+
23.2 15“ version
23.2.1 Main dimensions
118
BEETLE/ iSCAN EASY eXpress+
119
BEETLE/ iSCAN EASY eXpress+
23.2.2 Integration dimensions
120
BEETLE/ iSCAN EASY eXpress+
23.2.3 Dimensions with table and wall adapter
with table adapter with wall adapter
121
BEETLE/ iSCAN EASY eXpress+
23.3 19“ version
23.3.1 Main dimensions
122
23.3.2 Integration dimensions
BEETLE/ iSCAN EASY eXpress+
123
BEETLE/ iSCAN EASY eXpress+
23.3.3 Dimensions with table and wall adapter
with table adapter with wall adapter
124
23.4 27“ version
23.4.1 Main dimensions
BEETLE/ iSCAN EASY eXpress+
125
BEETLE/ iSCAN EASY eXpress+
23.4.2 Integration dimensions
126
BEETLE/ iSCAN EASY eXpress+
23.4.3 Dimensions with table and wall adapter
with table adapter with wall adapter
127
BEETLE/ iSCAN EASY eXpress+
24 Block diagram
Block diagram with Sensormatic
The optional components are highlighted in green.
128
Block diagram for Hybrid-Option
BEETLE/ iSCAN EASY eXpress+
The optional components are highlighted in green.
129
BEETLE/ iSCAN EASY eXpress+
25 Certifications of the Manufacturer
The device complies with the requirements of the EU directives
2014/30/EU with regard to “Electromagnetic compatibility” and, if applicable, 2014/35/EU “Low Voltage Directive” and 2011/65/EU
"Restriction of Hazardous Substances". Therefore, you will find the CE mark on the device or packaging.
The system is approved for the USA and Canada.
Supplier's Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Responsible Party in the U. S.: Diebold Nixdorf
Address:
Contact:
FCC Compliance Statement
5995 Mayfair Road
N. Canton, OH 44720 / USA [email protected]
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his expense. Modifications not authorized by the manufacturer may void user’s authority to operate this device.
This class A digital apparatus complies with Canadian ICES-003.
Cet appareil numerique de la classe A est conforme à la norme NMB-003 du Canada. (2)
This device must accept any interference received, including interference that may cause undesired operation.
130
BEETLE/ iSCAN EASY eXpress+
26 Recycling
The system was designed according to the Diebold Nixdorf standard "Environmentally
Conscious Product Design and Development”.
The system is manufactured without the use of CFCs and CCHs and is manufactured to a great extent of materials and components which are recyclable.
For recycling purposes do not attach any additional adhesive labels to the device.
Diebold Nixdorf disposes of old devices in a environmentally responsible manner at a recycling center that is ISO 9001 and ISO 14001 certified, as is the entire company.
Follow your local regulations regarding the disposal of toxic waste (such as the system ribbons).
Your Diebold Nixdorf vendor will answer any questions you may have concerning returning, recycling and disposal of our products.
131
Diebold Nixdorf
D-33094 Paderborn
Order No.: 01750341833D
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 6 About this Manual
- 6 Symbols
- 7 Warranty
- 8 Unpacking and Checking the System
- 8 Serial number
- 11 ESD (Electrostatic Sensitive Devices)
- 12 Important Notes
- 13 Connecting Peripherals
- 14 Tools You Need
- 15 Customer Requirements
- 16 Components
- 16 Exterior view
- 17 Interior view
- 17 15” and
- 19 Opening the device
- 20 Ventilating the system
- 22 Hand grips
- 23 Installation in the table adapter
- 23 Requirements
- 23 Drill pattern dimensions for 15” and 19” for table adapter
- 24 Drill pattern dimensions for 27” table adapter
- 25 Installation 15” and 19” version
- 28 Installation 27” version
- 29 Installation: Hybrid (15” and 19” only)
- 30 Delivery
- 30 Dimensions and weight
- 31 Display assembly
- 33 BA92 und BA
- 37 Connection of Barcode Scanners
- 38 Barcode scanner initialization
- 38 Datalogic Magellan 3450VSi
- 39 Honeywell CF
- 41 Connection of waiter lock
- 42 Installation: Wall Mounted Kiosk
- 42 Recommendation for wall mounting
- 42 Hole pattern for wall mounting (dimensions in mm)
- 42 15” and 19” BEETLE /iScan EASY eXpress
- 44 27” BEETLE /iScan EASY eXpress
- 45 Recommended materials
- 46 Installing the wall mount for 15” and 19” version
- 48 Inserting the system
- 49 Pillar mounting
- 49 Dimensions (in mm)
- 49 Optional base plate 15” and
- 50 Optional base plate
- 51 Pillar drill template
- 52 Example: Pillar mounting with
- 52 indicator, coupon box and base plate
- 53 Example: Pillar mounting of 19” and optional scale platform
- 54 Installation instructions: Self-Checkout on pillar
- 54 Self-Checkout with floor cabling
- 59 Self-Checkout with floor cabling and optional base plate
- 60 Self-Checkout with cabling “on the floor
- 60 Installing the basket shelf at the front side
- 62 Installing the basket shelf at side
- 62 Installing the security scale at front
- 65 Installing the security scale at side
- 66 Installing the coupon box
- 69 Installation sensormatic controller
- 73 Installing the signal indicator
- 76 Connecting the System
- 79 Removing the protection foil at the Display and Front surface
- 80 Installation in general
- 80 EFT (Electronic-Funds-Transfer)-Terminal
- 86 EFT ICT
- 89 EFT Worldline Valina
- 95 EFT Verifone P
- 102 EFT DESK
- 107 Cleaning Instructions
- 107 General Information
- 107 Maintenance and Service
- 107 Housing
- 108 Approved Cleaning Materials
- 109 Technical data
- 109 System
- 111 Display
- 114 Printer TH
- 116 Epson TM-T88VI
- 117 Custom printer
- 118 Magellan 3450VSi
- 119 Scanner Magellan 3200VSi
- 120 Scanner ZEBRA MS4717 CONE
- 121 Scanner Honeywell CF
- 121 RFID/NFC Modul
- 122 Dimensions (mm)
- 122 Orientation and vertical mounting
- 123 15“ version
- 123 Main dimensions
- 125 Integration dimensions
- 126 Dimensions with table and wall adapter
- 127 19“ version
- 127 Main dimensions
- 128 Integration dimensions
- 129 Dimensions with table and wall adapter
- 130 27“ version
- 130 Main dimensions
- 131 Integration dimensions
- 132 Dimensions with table and wall adapter
- 133 Block diagram
- 135 Certifications of the Manufacturer
- 136 Recycling