Signature 218 Series Installation Manual And User's Manual
Add to My manuals23 Pages
Signature 218 Series is a wall-mounted range hood that has a modern contemporary design that will enhance the look of any kitchen. The range hood features easy-to-use push-button controls with three different fan speeds to choose from. The included charcoal filters remove odors, while the dishwasher-safe baffle filters trap grease. The range hood also features two bright LED lights to illuminate your cooking surface.
advertisement
Installation Guide and Users Manual
218 Series
IMPORTANT:
5HDGDQGVDYHWKHVHLQVWUXFWLRQV
NOTICE:
Installer:
/HDYHWKLVJXLGHZLWKWKHKRPHRZQHU
Homeowner:
.HHSWKLVJXLGHIRUIXWXUHUHIHUHQFH
Wall Mount Range Hood
Rev. 1024u.1a
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The installation in this manual is intended for qualified installers, service technicians or persons with similar qualified background. Installation and electrical wiring must be done by qualified profession als and in accordance with all applicable codes and standards, including fire-rated construction.
'2127
attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background.
Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any parts for installing, cleaning or servicing.
Activating any switch ON before completing installation may cause ignition or an explosion.
Due to the size and weight of this range hood, two people installation is recommended.
To reduce the risk of fire, electric shock, or injury to persons:
For general ventilating use only.
'2127
use to exhaust hazardous or explosive materials and va
SRUV
The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally.
Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make
VXUHWRYHQWDLURXWVLGH'2127
vent exhaust into spaces between walls, crawl spaces, ceiling, attics
RUJDUDJHV
Ducted fans MUST always be vented to the outdoors.
Use only metal ductwork and this unit MUST be grounded.
Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent back drafting.
When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid
GHQXWLOLWLHV
All electrical wiring must be properly installed, insulated and grounded.
Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire.
Check all joints on duct work to insure proper connection and all joints should be properly taped.
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
YHQGRU
To reduce the risk of a stove top grease fire:
Keep all fan, baffle, spaces, filter, grease tunnel, oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle, spaces, filter, grease tunnel and oil container.
Always turn range hood ON when cooking at high heat or when cooking flaming foods.
Use high settings on cooking range only when necessary.
Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
Page 1
Important Safety Notice
Read all Instructions before Installing and operating this appliance
Clean ventilating fan frequently.
Always use appropriate cookware and utensils size.
Always use cookware appropriate for the size of the surface element.
To reduce the risk of injury to persons in the event of a stove top grease fire:
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn OFF the burner.
BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned.
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames DO
NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or 911.
DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.
Use an extinguisher ONLY if:
You know you have a Class A, B, C extinguisher, and you already know how to operate it.
The fire is small and contained in the area where it is started.
The fire department is being called.
You can fight the fire with your back to an exit.
To reduce the risk of injury to persons in the event of a gas leaks:
Extinguish any open flame.
DO NOT turn on the range hood fan or any type of ventilator.
DO NOT turn on the lights or any type of appliance.
Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and fire department, or dial your local emergency service immediately.
Your safety and the safety of others is very important. We have provided many important safety mes sages in this manual and on your appliance. Always read and obey all safety messages. All safety mes sages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
ZKDWFDQKDSSHQLIWKHLQVWUXFWLRQVDUHQRWIROORZHG
WARNING
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others.
All safety messages will follow the safety alert symbol and the word “WARNING”.
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
The manufacturer and/or distributor/reseller further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
The manufacturer and/or distributor/reseller will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
Page 2
Table of Contents
INSTALLATION
7RROVQHHGHG
3DUWVVXSSOLHG
Venting requirements.......................................5
Mount heights & clearance...........................5-6
Calculating vent system length.......................6
Venting methods & ductless conversion..........7
Charcoal filters & electrical requirements.......8
Preparation......................................................9
Installation................................................10-11
Installation overview.....................................11
USE AND CARE
5DQJHKRRGRSHUDWLRQV
12 1
Troubleshooting...........................................14
Use and care information...............................15
Specifications..............................................15
Wiring diagram..............................................16
MAINTENANCE
Cleaning, replacing filter & light bulb.........17
WARRANTY
Coverage & exceptions.................................18
Disclaimer & contact information.................19
Tools needed:
Marker or
SHQFLO Utility knife
0HDVXULQJ
WDSH
/HYHO
3RZHUHG
VFUHZGULYHU
RUGULOO
Flat-blade and
3KLOOLSVVFUHZ
GULYHUV
3DJH
Parts supplied:
5DQJH+RRG
(vary with model)
Grease/Oil Cup
Lower Standard Chimney Upper Standard Chimney
Mounting Bracket
(Not supplied with re-circulating kit)
)ODSSHUV
$
Qty: 4 PCS
(For sheet rock only)
%
Qty: 4 PCS
Charcoal filter
(Optional re-circulating kit,
SUHLQVWDOOHGZKHQRUGHUHG together with range hood)
Glass Canopy Screw
Qty: 4 PCS
(Optional with glass canopy)
Hex Key
Qty: 1 PCS
(Optional with glass canopy)
C
Qty: 4 to 8 PCS
(Vary with model)
$LU'LYHUWHU
(Optional re-circulating kit, pre-installed when ordered together with range hood)
Flexible
Duct Tube
3DJH
Venting Requirements Height & Clearance
Vent system must terminate to the outside
(roof or side wall).
Maximum* ceiling clearance
DO NOT terminate the vent system in an at
WLFRURWKHUHQFORVHGDUHD
110” at 31” hood mounting height above countertop/stove
DO NOT use 4” (10.2 cm) laundry-type wall
FDSV
(may vary with different model). Chimney extensions available for higher ceiling.
Use metal/aluminum vent only. Rigid metal/
DOXPLQXPYHQWLVUHFRPPHQGHG
'2127XVHSODVWLFYHQW
Always keep the duct clean to ensure proper airflow.
Calculate the following figures before instal lation:
1.
2.
Distance from the floor to the ceiling.
Distance between the floor to the coun-
3.
4.
tertop/stove (recommend* 28” to 31”).
Distance between the countertop/stove to the range hood.
Height of hood and duct cover.
For the most efficient & quiet operation:
A distance of 28” to 31” is recommended* between stove top and the bottom of range
KRRG
It is recommended that the range hood be vented vertically through the roof through 6”
(15.24 cm) or bigger round metal/aluminum vent work.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24” (61 cm) of straight vent between the elbows if more than one elbow is used.
DO NOT install two elbows together.
The length of vent system and number of elbows should be kept to a minimum to pro vide efficient performance.
The vent system must have a damper. If roof or wall cap has a damper, DO NOT use damper (if supplied) on top of the range
KRRG
Use silver tape or duct tape to seal all joints in the vent system.
Use caulking to seal exterior wall or roof
RSHQLQJDURXQGWKHFDS
Min: 28”
Max: 31”
Max*: 110”
36” base
Countertop/Stove
0RXQWLQJ
Bracket
Standard
8SSHU
Chimney
Extension available*
Standard
/RZHU
Chimney
Extension available*
5DQJHKRRG
* Higher ceiling requires chim ney extension. Available at your
ORFDOUHVHOOHUV
* Due to different ceiling height configurations, rec ommended height may not be applicable.
Page 5
IMPORTANT:
A minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separately) must be used to maintain maximum airflow efficiency.
Flexible 6” round duct provided for convenience, always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided duct.
3OHDVHXVH Duct Run Calculation
below to compute the total available duct run when using elbows, transitions
DQGFDSV
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6” to 7” or 8”. If a reducer is used, install a long reducer instead of a pancake reducer. Reduc ing duct size will restrict airflow and decrease airflow, thus reduce duct size as far away from opening as pos sible.
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.
Minimum mount height between stove top to hood bottom should be no less than 28-inch*.
Maximum mount height between stove top to hood bottom should be no higher than 31-inch*.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency.
If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood mounting height above range.
* Due to different ceiling height configurations, recommended height may not be applicable.
Minimum Duct Size:
Round - 6” minimum
Rectangular - 3-1/4 x 10” minimum (requires a 6” to 3-1/4x10” adaptor, not supplied)
Calculating Vent System Length
To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system from the recommended maximum duct run.
Duct Run Calculation:
Recommended maximum run
6” or 3-1/4 x 10” duct 50 ft
Vent piece deduction
Each 90º elbow used
Each 45º elbow used
Each 6” to 3/14 x 10” transition used
Side wall cap with damper
5RRIFDS
9 ft
5 ft
7 ft
0 ft
0 ft
Duct Run Calcuation example:
One roof cap, two 90º elbow, and one 45º elbow used:
0ft + 9ft + 9ft + 5ft = 23ft used.
Deduct 23ft from 50ft, 27ft maximum available for straight duct run.
Page 6
Venting Methods
This range hood is factory set for venting through the roof or wall. For non-vented (re-circulating) installa tions, see Recirculating (Non-Vented) Kit on Page 10.
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
IMPORTANT:
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal/aluminum duct work only.
Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
Use caulking to seal exterior wall or roof opening around the cap.
Option 1:
Horizontal wall venting
Option 2:
Vertical roof venting
5RRIFDS
Side wall cap
Ductless Conversion
Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed.
When converted, the hood functions as a purifying hood rather than an exhaust hood. Fumes and exhaust from cooking is drawn and filtered by a set of charcoal filters. The air is then purified and re-circulated back
ZLWKLQWKHKRPH
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. Only when the exhaust option is not possible should you recourse to converting the hood into a purifying unit.
When converted to be a “purifying” unit, a set of charcoal filters and an air-diverter are required in addition to its standard aluminum filter set. Available at your local resellers. The standard aluminum filters are intended to capture residue from cooking, the optional charcoal filters help to purify fumes exhausted from cooking, and the optional air-diverter redirects filtered clean air back to the house.
Page 7
Charcoal Filter Installation
NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us.
1.
Remove aluminum filters on hood.
2.
Position the charcoal filters onto each side of the motor and turn until it locks. Re-install aluminum filters.
Charcoal filters must be replaced after 120 hours of use (or approximately every 2 to 3 months based on the average of 1 to 2 hours of daily cooking time). Available at your local resellers.
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
(Please consult with a qualified electrician for 220-Volt 50 Hz voltage)
It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/
NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No.
0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that
WKHJURXQGSDWKLVDGHTXDWH
A 120-Volt, 60 Hz, AC-only (USA & Canada standard), fused electrical supply is required on a separate 15-amp circuit, fused on both sides of the line.
'2127JURXQGWRDJDVSLSH
Check with a qualified electrician if you are not sure that the range hood is properly grounded.
'2127KDYHDIXVHLQWKHQHXWUDORUJURXQGFLUFXLW
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
The range hood must be connected with copper wire/plug only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at each end of the power supply cable.
Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specified on the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code
ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22.
2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit con nector must be provided at each end of the power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Page 8
Preparation
Advanced Preparations:
1.
Be familiar with the controls of the range hood by reading
WKURXJK
Range Hood Operations,
3DJH
12
2.
Place the range hood on a flat, stable surface. Connect the
WARNING
Excessive Weight range hood to a designated standard outlet (please refer the
Require three or more person to move and product label for the suitable voltage of this unit) and turn on the range hood. Verify all operations of the range hood by
UHIHUULQJWR
Range Hood Operations,
3DJH
12 install this range hood. Spinal or other bodily injuries could occur if it is not followed.
Place all supplied parts and required hardware on a flat, stable surface and verify the existence of all supplied
SDUWVOLVWHGRQ3DJH
Carefully remove the white plastic protective coat from the chimney covers and range hood.
Preparations:
NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.
1.
2.
Determine and mark the center line on the ceiling where the range hood will be installed. Make sure there is proper clearance within the ceiling or wall for exhaust vent.
Due to the weight and size of this unit, please make sure that the support system or framework being used is stable and secure in the wall.
Put a thick, protective covering over counter top, cook top or range to protect from damage or dirt. Remove any hazardous objects around the area when installing.
Mark the locations of the support mounting bracket holes, vent cutout (if used) and power supply cable cutout
5.
6.
on the ceiling. Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent (see
Venting requirements
DQG
Electrical requirements , Pages 6-8).
If venting to the outside install vent system (see Venting Requirements , Page 5). Use caulking to seal exterior
ZDOORUURRIRSHQLQJV
Disconnect main electrical supply, prepare and run electrical wiring through ceiling or wall. Leave approxi mately 12” of electrical cord hanging from the ceiling. Do not restore power until wiring is completed.
7.
Disconnect power cord, remove the aluminum filter by pressing on the latch toward the direction of solid ar row while holding the metal handle, gently pull the aluminum filter toward the direction of dashed arrow as
VKRZQLQ)LJXUH
1
Remove the grease cup by sliding it sideway, see Figure 2 for location of the grease cup.
8.
9.
10.
Set aside the aluminum filters and grease cup until the range hood is properly installed.
If the range hood comes with a glass canopy and has not already been mounted to the hood, loosen the four canopy screws and washers from the hood top, carefully place the canopy on the hood top, and loosely tighten the four canopy screws along with washers. DO NOT put excessive pressure against the glass.
WARNING
Severe Injury
Rotating fan can cause severe injury. Stay clear of fan when motor is running.
Page 9 )LJXUH
1
)LJXUH
2
Installation
Installations (refer to Page 4 & 11 for parts) :
1.
Measure the distance between stove top and the bottom of
2.
3.
range hood. A distance of 28” to 31” is recommended*.
*
Due to different ceiling height configurations, recommended height may not be applicable.
Make sure the range hood is level and not tilted. Mark the locations of the hanging bracket holes on the wall as
VKRZQLQ)LJXUH$DQG)LJXUH%
Recirculating (Non-Vented) Kit:
If Re-Circulating Kit is not purchased, skip this step. Place the air diverter directly
above the range hood with its 6” round hole faces downward. Level it and mark the locations of the air dirverter holes on the wall.
5.
6.
7.
Place the mounting bracket directly
above the range hood, level it, and mark the locations of the mounting bracket holes on the wall.
Place aside all equipments, locate marked regions and drill holes. Attach range hood to wall using anchors
recommended for your type of wall:
Sheet rock wall: Attach range hood to stud blockings if possible. If stud blockings are not available, it is required to build a supporting structure behind the sheet rock for best weight support.
Concrete wall: Use designated screws (not provided).
Wood wall: Use at least 4” long wood screws (not provided).
Fasten two Type “A” anchors (for range hood and for mounting bracket or air diverter) on the wall as shown in Figure 4. Loosely fasten two Type “B” screws onto anchors, DO NOT fasten screws all the way. Hang the range hood on the Type “B” screws and hand tighten them. Leave approximately 1/16” of gap from the wall
WRWKHUDQJHKRRG
Place the mounting bracket (or air diverter) against the wall and align the holes from mounting bracket (or air diverter) with holes from Type “A” anchors, fasten two Type “B” screws through the holes onto the anchors as shown in Figure 5. Leave approximately 1/16” of gap from the wall to the mounting bracket (or air diverter).
)LJXUH$
)DVWHQPRXQWLQJ bracket
)LJXUH
Secure
XSSHU
VXSSRUW
IUDPH
Slide up and secure upper chimney to mounting bracket
)LJXUH%
+ROGLQSRVLWLRQDQG secure lower chimney
WRUDQJHKRRG
Figure 5
Page 10
Installation
(Continued)
8.
Calculate the height of the duct tube and extend approximately 6 inches longer than required, connect the lower end of the duct tube to the range hood and the upper end to the vent system (or air diverter). Make sure the
9.
main electrical supply remains disconnected then connect power plug to the electrical cord or wall plug.
Have one person carefully position both upper and lower chimneys on the range hood, let the second person slide the sides of the chimneys into the 1/16” gap. Fasten both chimneys with four Type “C” screws.
10.
Install grease cup and aluminum filters then check the operation of the range hood.
Installation Overview
C
$ %
Mounting Bracket
$
Qty: 4 PCS
(For sheet rock only)
%
Qty: 4 PCS
Re-circulating kit exhaust
(Re-circulating kit not shown)
Upper chimney
Glass Canopy Screw
Qty: 4 PCS
(Optional with glass canopy)
C
Qty: 4 to 8 PCS
(Vary with model)
Hex Key
Qty: 1 PCS
(Optional with glass canopy)
Duct work and electric
ZLULQJUHJLRQ
Lower chimney
$ %
Note: Type “A” anchors are designed for dry wall. Not to be used with any other types of walls.
C
6” Round duct (exhaust)
0RWRUKRXVLQJ
Electric circuit box
(Location varies)
:DOOPRXQW
UDQJHKRRG
3DJH
11
Range Hood Operations
Control Panel Layout and Buttons Configurations:
3RZHU
Decrease Value
Blower Power Indicator
Blower Speed Indicator
Light Power Indicator
/LJKW
Increase Value
Power-On Elapsed Digital Timer
Power-Off Delay Digital Timer
Power-Off Delay Timer Indicator
The range hood is designed to remove smoke, cooking vapors and odors from the cook top area. For best results, start the range hood before cooking and allow it to operate several minutes after the cooking incomplete to clear all smoke and odors from the kitchen.
Button functions:
Power: Power ON/OFF and activate power-off delay timer.
Decrease Value: Blower (motor) speed decrease, timer value decrease, and enter timer mode.
Increase Value: Blower (motor) speed increase timer value increase, and cumulative timer reset.
Blower Power Indicator: Lights up when blower (motor) is running.
Blower Speed Indicator: Shows current blower (motor) speed (1-6).
Light Power Indicator: Lights up when lights turned on.
Light: Turns ON/OFF and dim halogen lights.
Power-On Elapsed Digital Timer: Indicates the accumulated time the system is running.
Power-Off Delay Digital Timer: Indicates the length of time left for delay off function.
Power-Off Delay Timer Indicator: Lights up when auto-shutdown delay timer function is on.
Controls:
Automatic cleaning reminder:
When blower (motor) starts to rotate, cumulative running time will be shown in
Power-On Elapsed
Digital Timer
. This timer icon flashes when 30 hours is up and reminds user to clean the aluminum
filter.
After cleaning the filter and when the motor is not in use, press and hold
Increase Value
button over 3 seconds to reset the timer. Please note that turning off the system will not reset the
Power-On Elapsed
Digital Timer
Adjusting the blower (motor) speed:
3UHVV
Power button once to turn on the system. The
Blower Power Indicator
icon flashes showing that the blower (motor) is ready.
Decrease Value
button will decrease the speed of the blower (motor) from
6 to 1 (strongest to quietest).
Increase Value
button will increase the speed of the blower (motor) from
1 to 6 (quietest to strongest).
3UHVV
Power button once to turn off the system.
Note: The system saves user configurations, settings such as light, timer and blower (motor) speed will remain the same the next time it is turned on.
3DJH
12
Range Hood Operations
(Continued)
Control Panel Layout and Buttons Configurations:
3RZHU
Decrease Value
Blower Power Indicator
Blower Speed Indicator
Light Power Indicator
/LJKW
Increase Value
Power-On Elapsed Digital Timer
Power-Off Delay Digital Timer
Power-Off Delay Timer Indicator
Controls:
Adjusting the timer function:
While the blower (motor) is not running, press and hold
Decrease Value button over 3 seconds to enter timer mode. Adjust to desired period of delay off timer by pressing
Increase Value RU
Decrease
Value
button (minimum 1 minute to maximum 15 minutes). This setting will be saved immediately.
Activating the timer function:
While the blower (motor) is running, press and hold Power button for over 3 seconds to activate delay off timer. Power-off delay indicator will lit up and power-off delay digital timer will begin to countdown, when it reaches zero, the blower (motor) will shut down.
Adjusting the light:
3UHVV Light
button once to turn on the lights, and once again to turn off the lights.
While the lights are off, press and hold
Light
button for over 3 seconds to dim the lights from low to high. Level of brightness will be stored in system’s memory.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Note: Light settings are independent from other settings (including power-off delay) and lights has to be manually turned on or off.
Note: The system saves user configurations, settings such as light, timer and blower (motor) speed will remain the same the next time it is turned on.
3DJH
1
Troubleshooting
1.
2.
5.
If the range hood or halogen light does not operate after installation:
The range hood vibrates when the blower is on:
The blower or fan seems weak:
The lights work but the blower is not spinning at all, is stuck or is rattling.
The hood is not venting out properly:
Check if the range hood has been plugged in, make sure that all power has been turned back ON, fused not blown and all electrical wiring are properly con
QHFWHG
Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs. See
Replacing the light bulbs
on Page 17.
The range hood might not have been secured prop erly on to the ceiling or wall. Check with your in
VWDOOHU
Check that the duct sized used is at least 6” or 3-1/4 x 10”. Range hood WILL NOT function efficiently with insufficient duct size. For example: 7” duct over 6” hole and loosely secured.
Check if duct is clogged or if damper unit (half-cir cular flapper) is not installed correctly or opening properly. A tight mesh on a side wall cap unit might also cause restriction to the air flow.
The blower might be jammed or scraping the bot
WRPGXHWRVKLSSLQJGDPDJH3OHDVHFRQWDFWXVLP mediately.
Make sure the distance between the stove top and the bottom of the hood is within* 28” and 31” in distance. *
Due to different ceiling height configurations, recommended height may not be applicable
Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed, and taped.
Make sure the power is on high speed for heavy cooking.
6.
Purpose of the slots/holes/openings near the top of the upper chimney:
These slots/holes/openings are used to exhaust cleaned air with optional re-circulating kit. If you did not install one, you do not need them.
NOTE:
For all other inquiries, please contact us. Our contact information can be found on the back cover page.
3DJH
1
Use and Care Information
Operations:
Read and understand all instructions and warnings in this manual before operating the appliance. Save these
LQVWUXFWLRQVIRUIXWXUHUHIHUHQFH
Always leave safety grills and filters in place. Without these components, operating blowers could catch on to hair, fingers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.
NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch fire. The risk of self combustion is higher when the oil has been used several times.
NEVER cook on “open” flames under the range hood. Check deep-fryers during use: Superheated oil may be flammable.
Cleaning:
The saturation of greasy residue in the blower and filters may cause increased inflammability. Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.
Filters must be cleaned periodically and free from accumulation of cooking residue (see cleaning instructions on Page 17). Old and worn filters must be replaced immediately.
DO NOT operate blowers when filters are removed. Never disassemble parts to clean without proper instruc tions. Disassembly is recommended to be performed by qualified personnel only. Read and understand all instructions and warnings in this manual before proceeding.
Specifications
Body
3RZHU5DWLQJ
General Input Power
Specifications
* :
Stainless Steel / Tempered Glass
220V/50Hz or 120V/60Hz (USA & Canada standard)
288 W (218W + 2x35W)
Motor Input Power
0RWRU5HYROXWLRQ
218 W
600 RPM (±10%) to 1800 RPM (±10%)
Levels Of Speed Control 6 Levels
Maximum Airflow 860 CFM
$LU3UHVVXUH
320 pa
Noise Level (dB / sone) Approximately 23 / 0.3 to 68 / 7.0 (Lowest to highest Speed)
Motor Type Dual Chamber Ultra Quiet
Fan Type
Control Type
Filtration Type
Illumination
Venting Size
Interference Protection
Dual Centrifugal / Sirocco
6 Speed Electronic Control Panels with LCD Display
Aluminum Filter with Reversible Handle
35W Maximum, Dimmable
Top, 6 inches Round
Radio Frequency Interference Protected
* Subject to change without notice, please contact your local reseller for details.
Page 15
Wiring Diagram
Six Speed with Type GU10 Bulb
Six Speed with Type MR16 Bulb
Page 16
Maintenance
For optimal operation, clean range hood and all baffle/spacer/filter/grease tunnel/oil container regularly. Regular care will
KHOSSUHVHUYHWKHDSSHDUDQFHRIWKHUDQJHKRRG
Cleaning Exterior surfaces:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g. Comet
Power Scruv
, EZ-Off
oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel surface. For heavier soil use liquid degrease such as “Forumla 409
” or “Fantastic
” brand cleaner.
If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting
FOHDQLQJVROXWLRQRQWRRULQWRWKHFRQWUROSDQHO)ROORZGLUHFWLRQVRIWKHVWDLQOHVVVWHHOFOHDQHU
CAUTION: Do not leave on too long as this may cause damage to hood finish.
Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood.
After cleaning, you may use non abrasive stainless steel polish such as 3M
or ZEP
, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
'2127DOORZGHSRVLWVWRDFFXPXODWHRUUHPDLQRQWKHKRRG
DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.
DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after ex posure and wipe dry with a clean cloth.
Cleaning Aluminum Grease Filter / Stainless Steel Filterless Grill:
IMPORTANT: Drain oil from oil containers before oil and residue overflow!
The metal filters fitted by the factory are intended to filter out residue and grease from cooking. It need not be replaced on a regular basis but are required to be kept clean.
Filters should be cleaned after every 30 hours of use.
Remove and clean by hand or dishwasher. Spray “Formula 409
” or equivalent degreasing detergent and leave to soak if heavily soiled. Dry filters and re-install before using hood.
Replacing Filters:
Should filters wear out due to age and prolonged use, please contact your local reseller for replacement filters.
Note: Also replace damaged filter that has punctured or broken mesh, bent or broken frame.
Replacing the light bulb:
This range hood uses halogen bulb (please refer to the actual specification of the hood purchased):
USA/Canada:
35W Type MR16 12V / Type GU10 120V
Align arrows on both rings
Europe and other Countries:
35W Type MR16 12V / Type GU10 220V
Make sure the range hood is unplugged or turn OFF breaker.
Make sure the lights are cool to touch, carefully align the ar
URZRQWKHLQQHUULQJZLWKWKHDUURZRQWKHRXWHUULQJZKHUHLW says OPEN. The inner ring will loosen and the light bulb will be available for removal. Install a new halogen light bulb and
UHYHUVHWKHVWHSV
Turn ON breaker and range hood to test for operation.
WARNING
Hazard of Burns!
Light bulb become extremely hot when turned on.
DO NOT touch bulb until switched off and cooled.
Touching hot bulbs could cause serious burns.
Page 17
Warranty
T O O B T A I N S E R V I C E U N D E R W A R R A N T Y :
Y u mu st p re se nt p ro of f o f f or i ig i in al l p ur h as e da te .
Pl ea se p ro vi i d a n or i ig i in al l d at t d p ro of f o f f pu rc ha se ( ( sa l le s re ce i ip t t / / i in vo i ic e) ) i i n or d r r t to o bt ai i n se rv i ic e un d r r wa rr an t y .
)LYH
Year Parts Warranty:
For
ILYH
year
V
from the date of original purchase, your local reseller will provide free of charge, non-consumable replace ment parts or components that failed due to manufacturing defects. Subject to the conditions and limitations set forth below, your local reseller will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. Repaired parts or replacement products will be provided by your local reseller on an exchange basis, and will be either new or refurbished to be functionally equivalent to new. The consumer is re sponsible for all shipping costs. Consumable parts not covered by this warranty include but not limited to: Light bulbs, metal, aluminum and charcoal filters.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary home use.
This Warranty Will Be Voided When:
Product damaged through negligence, improper installation, accident, abuse, misuse, natural disaster, insufficient or excessive electrical supply, abnormal mechanical or environmental conditions, or any unauthorized disassembly, repair, modification, or failure to follow installation instructions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than your local reseller’s authorized agents. This limited warranty also does not apply to any product on which the original identification information has been altered, obliterated or removed, has not been handled or packaged correctly or has been sold as second-hand.
What is Not Covered:
Consumable parts such as light bulbs, metal and charcoal filters. The natural wear of finish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage, or improper installation. Damage of product caused by accident, fire, floods or act of God. The manufacturer and/or distributor/reseller is not liable for, and does not cover under warranty, any loss of properties or any costs associated with removing, servicing, installing, or determining the source of problems with this
SURGXFW
This warranty is valid in the country of the original purchase at retail. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties, including the war ranty of merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.
To obtain warranty service, you may contact your local reseller from which you purchased this product. Please confirm the terms of your local reseller’s policies prior to contacting. Typically, you must include product identification information, including model number and serial number with a detailed description of the problem you are experiencing. You must also include proof of the date of original retail purchase as evidence that the product is within the applicable warranty period.
The information in this document is subject to change without notice, please contact your local reseller for updated details.
Page 18
Disclaimer
Carefully inspect all items for damages before accepting delivery. note any damages on the freight bill or express receipt. request name and signature of the carrier’s agent and keep copy to support your claim. Upon a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with
Damages caused during transit are not covered under our warranty
Please inspect contents of package(s) carefully upon receiving! W
" #"$ " days. NOTE: Items were thoroughly tested and carefully packed in our factory before shipping.
Products must be returned in good working condition with ALL original parts and documentation packed in
'<< = >? #@ merchandise is exchanged for items of equal or greater amount. Exchanges or returns may not be accepted if any packaging is missing.
Make sure to inspect the hood for damages and defects before installation.
-
Service visits not covered under warranty will carry a service charge.
Before Installation: Return for exchange or refund (please see above for acceptable returns).
After Installation:
NO
exchange or refund.
Contact Us
If you need any assistance, please contact Signature Hardware. Please have your order number and model of the range hood ready. This information will help us better respond to your request.
If you need replacement parts, we recommend that you only use genuine parts. Our accessories and parts are in durability and reliability, providing a factory match, factory-installed appearance and functionality tailored to each individual range hood model.
Contact Signature Hardware Customer Service :
>X[\\X[X]][^
_ X`{[{?? >>{??
|{[{?? }{??
~{[{?? {?
Sunday - closed
The information in this document is
=
to change without notice, please contact us f or updated details.
Page
>
Your Notes
Page 20
Your Notes
3DJH
21
advertisement
Related manuals
advertisement
Table of contents
- 6 Venting requirements
- 6 Mount heights & clearance
- 7 Calculating vent system length
- 8 Venting methods & ductless conversion
- 9 Charcoal filters & electrical requirements
- 10 Preparation
- 11 Installation
- 12 Installation overview
- 15 Troubleshooting
- 16 Use and care information
- 16 Specifications
- 17 Wiring diagram
- 18 Cleaning, replacing filter & light bulb
- 19 Coverage & exceptions
- 20 Disclaimer & contact information