Signature 218 Series Installation Manual And User's Manual

Add to My manuals
23 Pages

advertisement

Signature 218 Series Installation Manual And User's Manual | Manualzz

Installation Guide and Users Manual

218 Series

IMPORTANT:

5HDGDQGVDYHWKHVHLQVWUXFWLRQV

NOTICE:

Installer:

/HDYHWKLVJXLGHZLWKWKHKRPHRZQHU

Homeowner:

.HHSWKLVJXLGHIRUIXWXUHUHIHUHQFH

Wall Mount Range Hood

Rev. 1024u.1a

Important Safety Notice

Read all Instructions before Installing and operating this appliance

‡

‡

‡

The installation in this manual is intended for qualified installers, service technicians or persons with similar qualified background. Installation and electrical wiring must be done by qualified profession als and in accordance with all applicable codes and standards, including fire-rated construction.

'2127

attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background.

Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any parts for installing, cleaning or servicing.

Activating any switch ON before completing installation may cause ignition or an explosion.

Due to the size and weight of this range hood, two people installation is recommended.

‡

‡

‡

‡

‡

‡

‡

‡

‡

‡

‡

‡

‡

‡

To reduce the risk of fire, electric shock, or injury to persons:

For general ventilating use only.

'2127

use to exhaust hazardous or explosive materials and va

SRUV

The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally.

Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make

VXUHWRYHQWDLURXWVLGH'2127

vent exhaust into spaces between walls, crawl spaces, ceiling, attics

RUJDUDJHV

Ducted fans MUST always be vented to the outdoors.

Use only metal ductwork and this unit MUST be grounded.

Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent back drafting.

When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid

GHQXWLOLWLHV

All electrical wiring must be properly installed, insulated and grounded.

Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease fire.

Check all joints on duct work to insure proper connection and all joints should be properly taped.

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the

YHQGRU

‡

‡

‡

‡

To reduce the risk of a stove top grease fire:

Keep all fan, baffle, spaces, filter, grease tunnel, oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, baffle, spaces, filter, grease tunnel and oil container.

Always turn range hood ON when cooking at high heat or when cooking flaming foods.

Use high settings on cooking range only when necessary.

Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

Page 1

Important Safety Notice

Read all Instructions before Installing and operating this appliance

‡

‡

‡

Clean ventilating fan frequently.

Always use appropriate cookware and utensils size.

Always use cookware appropriate for the size of the surface element.

‡

‡

‡

To reduce the risk of injury to persons in the event of a stove top grease fire:

SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn OFF the burner.

BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned.

KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames DO

NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or 911.

DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.

Use an extinguisher ONLY if:

‡

‡

‡

‡

You know you have a Class A, B, C extinguisher, and you already know how to operate it.

The fire is small and contained in the area where it is started.

The fire department is being called.

You can fight the fire with your back to an exit.

‡

‡

‡

‡

To reduce the risk of injury to persons in the event of a gas leaks:

Extinguish any open flame.

DO NOT turn on the range hood fan or any type of ventilator.

DO NOT turn on the lights or any type of appliance.

Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and fire department, or dial your local emergency service immediately.

Your safety and the safety of others is very important. We have provided many important safety mes sages in this manual and on your appliance. Always read and obey all safety messages. All safety mes sages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you

ZKDWFDQKDSSHQLIWKHLQVWUXFWLRQVDUHQRWIROORZHG

WARNING

This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others.

All safety messages will follow the safety alert symbol and the word “WARNING”.

The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.

The manufacturer and/or distributor/reseller further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.

The manufacturer and/or distributor/reseller will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.

Page 2

Table of Contents

INSTALLATION

7RROVQHHGHG

3DUWVVXSSOLHG

Venting requirements.......................................5

Mount heights & clearance...........................5-6

Calculating vent system length.......................6

Venting methods & ductless conversion..........7

Charcoal filters & electrical requirements.......8

Preparation......................................................9

Installation................................................10-11

Installation overview.....................................11

USE AND CARE

5DQJHKRRGRSHUDWLRQV

12 1

Troubleshooting...........................................14

Use and care information...............................15

Specifications..............................................15

Wiring diagram..............................................16

MAINTENANCE

Cleaning, replacing filter & light bulb.........17

WARRANTY

Coverage & exceptions.................................18

Disclaimer & contact information.................19

Tools needed:

Marker or

SHQFLO Utility knife

0HDVXULQJ

WDSH

/HYHO

3RZHUHG

VFUHZGULYHU

RUGULOO

Flat-blade and

3KLOOLSVVFUHZ

GULYHUV

3DJH

Parts supplied:

5DQJH+RRG

(vary with model)

Grease/Oil Cup

Lower Standard Chimney Upper Standard Chimney

Mounting Bracket

(Not supplied with re-circulating kit)

)ODSSHUV

$

Qty: 4 PCS

(For sheet rock only)

%

Qty: 4 PCS

Charcoal filter

(Optional re-circulating kit,

SUHLQVWDOOHGZKHQRUGHUHG together with range hood)

Glass Canopy Screw

Qty: 4 PCS

(Optional with glass canopy)

Hex Key

Qty: 1 PCS

(Optional with glass canopy)

C

Qty: 4 to 8 PCS

(Vary with model)

$LU'LYHUWHU

(Optional re-circulating kit, pre-installed when ordered together with range hood)

Flexible

Duct Tube

3DJH

Venting Requirements Height & Clearance

‡

‡

‡

‡

‡

‡

‡

Vent system must terminate to the outside

(roof or side wall).

Maximum* ceiling clearance

DO NOT terminate the vent system in an at

WLFRURWKHUHQFORVHGDUHD

110” at 31” hood mounting height above countertop/stove

DO NOT use 4” (10.2 cm) laundry-type wall

FDSV

(may vary with different model). Chimney extensions available for higher ceiling.

Use metal/aluminum vent only. Rigid metal/

DOXPLQXPYHQWLVUHFRPPHQGHG

'2127XVHSODVWLFYHQW

Always keep the duct clean to ensure proper airflow.

Calculate the following figures before instal lation:

1.

2.

Distance from the floor to the ceiling.

Distance between the floor to the coun-

3.

4.

tertop/stove (recommend* 28” to 31”).

Distance between the countertop/stove to the range hood.

Height of hood and duct cover.

‡

‡

‡

‡

‡

‡

‡

‡

‡

‡

For the most efficient & quiet operation:

A distance of 28” to 31” is recommended* between stove top and the bottom of range

KRRG

It is recommended that the range hood be vented vertically through the roof through 6”

(15.24 cm) or bigger round metal/aluminum vent work.

The size of the vent should be uniform.

Use no more than three 90° elbows.

Make sure there is a minimum of 24” (61 cm) of straight vent between the elbows if more than one elbow is used.

DO NOT install two elbows together.

The length of vent system and number of elbows should be kept to a minimum to pro vide efficient performance.

The vent system must have a damper. If roof or wall cap has a damper, DO NOT use damper (if supplied) on top of the range

KRRG

Use silver tape or duct tape to seal all joints in the vent system.

Use caulking to seal exterior wall or roof

RSHQLQJDURXQGWKHFDS

Min: 28”

Max: 31”

Max*: 110”

36” base

Countertop/Stove

0RXQWLQJ

Bracket

Standard

8SSHU

Chimney

Extension available*

Standard

/RZHU

Chimney

Extension available*

5DQJHKRRG

* Higher ceiling requires chim ney extension. Available at your

ORFDOUHVHOOHUV

* Due to different ceiling height configurations, rec ommended height may not be applicable.

Page 5

‡

‡

‡

‡

‡

‡

‡

‡

‡

IMPORTANT:

A minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separately) must be used to maintain maximum airflow efficiency.

Flexible 6” round duct provided for convenience, always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided duct.

3OHDVHXVH Duct Run Calculation

below to compute the total available duct run when using elbows, transitions

DQGFDSV

ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6” to 7” or 8”. If a reducer is used, install a long reducer instead of a pancake reducer. Reduc ing duct size will restrict airflow and decrease airflow, thus reduce duct size as far away from opening as pos sible.

If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.

Minimum mount height between stove top to hood bottom should be no less than 28-inch*.

Maximum mount height between stove top to hood bottom should be no higher than 31-inch*.

It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency.

If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood mounting height above range.

* Due to different ceiling height configurations, recommended height may not be applicable.

‡

‡

Minimum Duct Size:

Round - 6” minimum

Rectangular - 3-1/4 x 10” minimum (requires a 6” to 3-1/4x10” adaptor, not supplied)

Calculating Vent System Length

To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system from the recommended maximum duct run.

Duct Run Calculation:

Recommended maximum run

6” or 3-1/4 x 10” duct 50 ft

Vent piece deduction

Each 90º elbow used

Each 45º elbow used

Each 6” to 3/14 x 10” transition used

Side wall cap with damper

5RRIFDS

9 ft

5 ft

7 ft

0 ft

0 ft

Duct Run Calcuation example:

One roof cap, two 90º elbow, and one 45º elbow used:

0ft + 9ft + 9ft + 5ft = 23ft used.

Deduct 23ft from 50ft, 27ft maximum available for straight duct run.

Page 6

Venting Methods

‡

‡

This range hood is factory set for venting through the roof or wall. For non-vented (re-circulating) installa tions, see Recirculating (Non-Vented) Kit on Page 10.

Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

‡

‡

‡

‡

IMPORTANT:

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.

All exhaust must be ducted to the outside.

Use metal/aluminum duct work only.

Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.

Use caulking to seal exterior wall or roof opening around the cap.

Option 1:

Horizontal wall venting

Option 2:

Vertical roof venting

5RRIFDS

Side wall cap

Ductless Conversion

‡

‡

‡

Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed.

When converted, the hood functions as a purifying hood rather than an exhaust hood. Fumes and exhaust from cooking is drawn and filtered by a set of charcoal filters. The air is then purified and re-circulated back

ZLWKLQWKHKRPH

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. Only when the exhaust option is not possible should you recourse to converting the hood into a purifying unit.

When converted to be a “purifying” unit, a set of charcoal filters and an air-diverter are required in addition to its standard aluminum filter set. Available at your local resellers. The standard aluminum filters are intended to capture residue from cooking, the optional charcoal filters help to purify fumes exhausted from cooking, and the optional air-diverter redirects filtered clean air back to the house.

Page 7

Charcoal Filter Installation

NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us.

1.

Remove aluminum filters on hood.

2.

Position the charcoal filters onto each side of the motor and turn until it locks. Re-install aluminum filters.

Charcoal filters must be replaced after 120 hours of use (or approximately every 2 to 3 months based on the average of 1 to 2 hours of daily cooking time). Available at your local resellers.

Electrical Requirements

IMPORTANT: Observe all governing codes and ordinances.

(Please consult with a qualified electrician for 220-Volt 50 Hz voltage)

‡

‡

It is the customer’s responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/

NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No.

0-M91 - latest edition** and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that

WKHJURXQGSDWKLVDGHTXDWH

A 120-Volt, 60 Hz, AC-only (USA & Canada standard), fused electrical supply is required on a separate 15-amp circuit, fused on both sides of the line.

'2127JURXQGWRDJDVSLSH

Check with a qualified electrician if you are not sure that the range hood is properly grounded.

'2127KDYHDIXVHLQWKHQHXWUDORUJURXQGFLUFXLW

IMPORTANT: Save this Installation Guide for electrical inspector’s use.

The range hood must be connected with copper wire/plug only.

The range hood should be connected directly to the fused disconnect (or circuit breaker) box through flexible armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at each end of the power supply cable.

Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specified on the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code

ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22.

2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit con nector must be provided at each end of the power supply cable (at the range hood and at the junction box).

Copies of the standards listed may be obtained from:

* National Fire Protection Association

Batterymarch Park

Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

Page 8

Preparation

Advanced Preparations:

1.

Be familiar with the controls of the range hood by reading

WKURXJK

Range Hood Operations,

3DJH

12

2.

Place the range hood on a flat, stable surface. Connect the

WARNING

Excessive Weight range hood to a designated standard outlet (please refer the

Require three or more person to move and product label for the suitable voltage of this unit) and turn on the range hood. Verify all operations of the range hood by

UHIHUULQJWR

Range Hood Operations,

3DJH

12 install this range hood. Spinal or other bodily injuries could occur if it is not followed.

Place all supplied parts and required hardware on a flat, stable surface and verify the existence of all supplied

SDUWVOLVWHGRQ3DJH

Carefully remove the white plastic protective coat from the chimney covers and range hood.

Preparations:

NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.

1.

2.

Determine and mark the center line on the ceiling where the range hood will be installed. Make sure there is proper clearance within the ceiling or wall for exhaust vent.

Due to the weight and size of this unit, please make sure that the support system or framework being used is stable and secure in the wall.

Put a thick, protective covering over counter top, cook top or range to protect from damage or dirt. Remove any hazardous objects around the area when installing.

Mark the locations of the support mounting bracket holes, vent cutout (if used) and power supply cable cutout

5.

6.

on the ceiling. Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent (see

Venting requirements

DQG

Electrical requirements , Pages 6-8).

If venting to the outside install vent system (see Venting Requirements , Page 5). Use caulking to seal exterior

ZDOORUURRIRSHQLQJV

Disconnect main electrical supply, prepare and run electrical wiring through ceiling or wall. Leave approxi mately 12” of electrical cord hanging from the ceiling. Do not restore power until wiring is completed.

7.

Disconnect power cord, remove the aluminum filter by pressing on the latch toward the direction of solid ar row while holding the metal handle, gently pull the aluminum filter toward the direction of dashed arrow as

VKRZQLQ)LJXUH

1

Remove the grease cup by sliding it sideway, see Figure 2 for location of the grease cup.

8.

9.

10.

Set aside the aluminum filters and grease cup until the range hood is properly installed.

If the range hood comes with a glass canopy and has not already been mounted to the hood, loosen the four canopy screws and washers from the hood top, carefully place the canopy on the hood top, and loosely tighten the four canopy screws along with washers. DO NOT put excessive pressure against the glass.

WARNING

Severe Injury

Rotating fan can cause severe injury. Stay clear of fan when motor is running.

Page 9 )LJXUH

1

)LJXUH

2

Installation

Installations (refer to Page 4 & 11 for parts) :

1.

Measure the distance between stove top and the bottom of

2.

3.

range hood. A distance of 28” to 31” is recommended*.

*

Due to different ceiling height configurations, recommended height may not be applicable.

Make sure the range hood is level and not tilted. Mark the locations of the hanging bracket holes on the wall as

VKRZQLQ)LJXUH$DQG)LJXUH%

Recirculating (Non-Vented) Kit:

If Re-Circulating Kit is not purchased, skip this step. Place the air diverter directly

above the range hood with its 6” round hole faces downward. Level it and mark the locations of the air dirverter holes on the wall.

5.

6.

7.

Place the mounting bracket directly

above the range hood, level it, and mark the locations of the mounting bracket holes on the wall.

Place aside all equipments, locate marked regions and drill holes. Attach range hood to wall using anchors

‡ recommended for your type of wall:

Sheet rock wall: Attach range hood to stud blockings if possible. If stud blockings are not available, it is required to build a supporting structure behind the sheet rock for best weight support.

‡

‡

Concrete wall: Use designated screws (not provided).

Wood wall: Use at least 4” long wood screws (not provided).

Fasten two Type “A” anchors (for range hood and for mounting bracket or air diverter) on the wall as shown in Figure 4. Loosely fasten two Type “B” screws onto anchors, DO NOT fasten screws all the way. Hang the range hood on the Type “B” screws and hand tighten them. Leave approximately 1/16” of gap from the wall

WRWKHUDQJHKRRG

Place the mounting bracket (or air diverter) against the wall and align the holes from mounting bracket (or air diverter) with holes from Type “A” anchors, fasten two Type “B” screws through the holes onto the anchors as shown in Figure 5. Leave approximately 1/16” of gap from the wall to the mounting bracket (or air diverter).

)LJXUH$

)DVWHQPRXQWLQJ bracket

)LJXUH

Secure

XSSHU

VXSSRUW

IUDPH

Slide up and secure upper chimney to mounting bracket

)LJXUH%

+ROGLQSRVLWLRQDQG secure lower chimney

WRUDQJHKRRG

Figure 5

Page 10

Installation

(Continued)

8.

Calculate the height of the duct tube and extend approximately 6 inches longer than required, connect the lower end of the duct tube to the range hood and the upper end to the vent system (or air diverter). Make sure the

9.

main electrical supply remains disconnected then connect power plug to the electrical cord or wall plug.

Have one person carefully position both upper and lower chimneys on the range hood, let the second person slide the sides of the chimneys into the 1/16” gap. Fasten both chimneys with four Type “C” screws.

10.

Install grease cup and aluminum filters then check the operation of the range hood.

Installation Overview

C

$ %

Mounting Bracket

$

Qty: 4 PCS

(For sheet rock only)

%

Qty: 4 PCS

Re-circulating kit exhaust

(Re-circulating kit not shown)

Upper chimney

Glass Canopy Screw

Qty: 4 PCS

(Optional with glass canopy)

C

Qty: 4 to 8 PCS

(Vary with model)

Hex Key

Qty: 1 PCS

(Optional with glass canopy)

Duct work and electric

ZLULQJUHJLRQ

Lower chimney

$ %

Note: Type “A” anchors are designed for dry wall. Not to be used with any other types of walls.

C

6” Round duct (exhaust)

0RWRUKRXVLQJ

Electric circuit box

(Location varies)

:DOOPRXQW

UDQJHKRRG

3DJH

11

Range Hood Operations

Control Panel Layout and Buttons Configurations:

3RZHU

Decrease Value

Blower Power Indicator

Blower Speed Indicator

Light Power Indicator

/LJKW

Increase Value

Power-On Elapsed Digital Timer

Power-Off Delay Digital Timer

Power-Off Delay Timer Indicator

‡

‡

The range hood is designed to remove smoke, cooking vapors and odors from the cook top area. For best results, start the range hood before cooking and allow it to operate several minutes after the cooking incomplete to clear all smoke and odors from the kitchen.

‡

‡

‡

‡

‡

‡

‡

‡

‡

‡

Button functions:

Power: Power ON/OFF and activate power-off delay timer.

Decrease Value: Blower (motor) speed decrease, timer value decrease, and enter timer mode.

Increase Value: Blower (motor) speed increase timer value increase, and cumulative timer reset.

Blower Power Indicator: Lights up when blower (motor) is running.

Blower Speed Indicator: Shows current blower (motor) speed (1-6).

Light Power Indicator: Lights up when lights turned on.

Light: Turns ON/OFF and dim halogen lights.

Power-On Elapsed Digital Timer: Indicates the accumulated time the system is running.

Power-Off Delay Digital Timer: Indicates the length of time left for delay off function.

Power-Off Delay Timer Indicator: Lights up when auto-shutdown delay timer function is on.

‡

‡

Controls:

‡

Automatic cleaning reminder:

When blower (motor) starts to rotate, cumulative running time will be shown in

Power-On Elapsed

Digital Timer

. This timer icon flashes when 30 hours is up and reminds user to clean the aluminum

‡ filter.

After cleaning the filter and when the motor is not in use, press and hold

Increase Value

button over 3 seconds to reset the timer. Please note that turning off the system will not reset the

Power-On Elapsed

Digital Timer

‡

Adjusting the blower (motor) speed:

3UHVV

Power button once to turn on the system. The

Blower Power Indicator

icon flashes showing that the blower (motor) is ready.

Decrease Value

button will decrease the speed of the blower (motor) from

6 to 1 (strongest to quietest).

Increase Value

button will increase the speed of the blower (motor) from

1 to 6 (quietest to strongest).

‡ 3UHVV

Power button once to turn off the system.

Note: The system saves user configurations, settings such as light, timer and blower (motor) speed will remain the same the next time it is turned on.

3DJH

12

Range Hood Operations

(Continued)

Control Panel Layout and Buttons Configurations:

3RZHU

Decrease Value

Blower Power Indicator

Blower Speed Indicator

Light Power Indicator

/LJKW

Increase Value

Power-On Elapsed Digital Timer

Power-Off Delay Digital Timer

Power-Off Delay Timer Indicator

‡

‡

‡

‡

Controls:

‡

Adjusting the timer function:

While the blower (motor) is not running, press and hold

Decrease Value button over 3 seconds to enter timer mode. Adjust to desired period of delay off timer by pressing

Increase Value RU

Decrease

Value

button (minimum 1 minute to maximum 15 minutes). This setting will be saved immediately.

Activating the timer function:

‡

While the blower (motor) is running, press and hold Power button for over 3 seconds to activate delay off timer. Power-off delay indicator will lit up and power-off delay digital timer will begin to countdown, when it reaches zero, the blower (motor) will shut down.

‡

‡

Adjusting the light:

3UHVV Light

button once to turn on the lights, and once again to turn off the lights.

While the lights are off, press and hold

Light

button for over 3 seconds to dim the lights from low to high. Level of brightness will be stored in system’s memory.

CAUTION: DO NOT touch the lights until switched OFF and cooled.

Note: Light settings are independent from other settings (including power-off delay) and lights has to be manually turned on or off.

Note: The system saves user configurations, settings such as light, timer and blower (motor) speed will remain the same the next time it is turned on.

3DJH

1

Troubleshooting

1.

2.

5.

If the range hood or halogen light does not operate after installation:

The range hood vibrates when the blower is on:

The blower or fan seems weak:

The lights work but the blower is not spinning at all, is stuck or is rattling.

The hood is not venting out properly:

‡

‡

‡

‡

‡

‡

‡

‡

‡

Check if the range hood has been plugged in, make sure that all power has been turned back ON, fused not blown and all electrical wiring are properly con

QHFWHG

Swap out light assembly to working ones to deter mine whether it is caused by defective bulbs. See

Replacing the light bulbs

on Page 17.

The range hood might not have been secured prop erly on to the ceiling or wall. Check with your in

VWDOOHU

Check that the duct sized used is at least 6” or 3-1/4 x 10”. Range hood WILL NOT function efficiently with insufficient duct size. For example: 7” duct over 6” hole and loosely secured.

Check if duct is clogged or if damper unit (half-cir cular flapper) is not installed correctly or opening properly. A tight mesh on a side wall cap unit might also cause restriction to the air flow.

The blower might be jammed or scraping the bot

WRPGXHWRVKLSSLQJGDPDJH3OHDVHFRQWDFWXVLP mediately.

Make sure the distance between the stove top and the bottom of the hood is within* 28” and 31” in distance. *

Due to different ceiling height configurations, recommended height may not be applicable

Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed, and taped.

Make sure the power is on high speed for heavy cooking.

6.

Purpose of the slots/holes/openings near the top of the upper chimney:

‡

These slots/holes/openings are used to exhaust cleaned air with optional re-circulating kit. If you did not install one, you do not need them.

NOTE:

For all other inquiries, please contact us. Our contact information can be found on the back cover page.

3DJH

1

Use and Care Information

‡

‡

‡

‡

‡

Operations:

Read and understand all instructions and warnings in this manual before operating the appliance. Save these

LQVWUXFWLRQVIRUIXWXUHUHIHUHQFH

Always leave safety grills and filters in place. Without these components, operating blowers could catch on to hair, fingers and loose clothing.

NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.

NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch fire. The risk of self combustion is higher when the oil has been used several times.

NEVER cook on “open” flames under the range hood. Check deep-fryers during use: Superheated oil may be flammable.

‡

‡

‡

Cleaning:

The saturation of greasy residue in the blower and filters may cause increased inflammability. Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.

Filters must be cleaned periodically and free from accumulation of cooking residue (see cleaning instructions on Page 17). Old and worn filters must be replaced immediately.

DO NOT operate blowers when filters are removed. Never disassemble parts to clean without proper instruc tions. Disassembly is recommended to be performed by qualified personnel only. Read and understand all instructions and warnings in this manual before proceeding.

Specifications

Body

3RZHU5DWLQJ

General Input Power

Specifications

* :

Stainless Steel / Tempered Glass

220V/50Hz or 120V/60Hz (USA & Canada standard)

288 W (218W + 2x35W)

Motor Input Power

0RWRU5HYROXWLRQ

218 W

600 RPM (±10%) to 1800 RPM (±10%)

Levels Of Speed Control 6 Levels

Maximum Airflow 860 CFM

$LU3UHVVXUH

320 pa

Noise Level (dB / sone) Approximately 23 / 0.3 to 68 / 7.0 (Lowest to highest Speed)

Motor Type Dual Chamber Ultra Quiet

Fan Type

Control Type

Filtration Type

Illumination

Venting Size

Interference Protection

Dual Centrifugal / Sirocco

6 Speed Electronic Control Panels with LCD Display

Aluminum Filter with Reversible Handle

35W Maximum, Dimmable

Top, 6 inches Round

Radio Frequency Interference Protected

* Subject to change without notice, please contact your local reseller for details.

Page 15

Wiring Diagram

Six Speed with Type GU10 Bulb

Six Speed with Type MR16 Bulb

Page 16

Maintenance

For optimal operation, clean range hood and all baffle/spacer/filter/grease tunnel/oil container regularly. Regular care will

KHOSSUHVHUYHWKHDSSHDUDQFHRIWKHUDQJHKRRG

‡

‡

‡

‡

‡

‡

Cleaning Exterior surfaces:

Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g. Comet

Power Scruv

Š

, EZ-Off

Š

oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel surface. For heavier soil use liquid degrease such as “Forumla 409

Š

” or “Fantastic

Š

” brand cleaner.

If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting

FOHDQLQJVROXWLRQRQWRRULQWRWKHFRQWUROSDQHO)ROORZGLUHFWLRQVRIWKHVWDLQOHVVVWHHOFOHDQHU

CAUTION: Do not leave on too long as this may cause damage to hood finish.

Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood.

After cleaning, you may use non abrasive stainless steel polish such as 3M

Š

or ZEP

Š

, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.

'2127DOORZGHSRVLWVWRDFFXPXODWHRUUHPDLQRQWKHKRRG

DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.

DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after ex posure and wipe dry with a clean cloth.

‡

‡

‡

Cleaning Aluminum Grease Filter / Stainless Steel Filterless Grill:

IMPORTANT: Drain oil from oil containers before oil and residue overflow!

The metal filters fitted by the factory are intended to filter out residue and grease from cooking. It need not be replaced on a regular basis but are required to be kept clean.

Filters should be cleaned after every 30 hours of use.

Remove and clean by hand or dishwasher. Spray “Formula 409

Š

” or equivalent degreasing detergent and leave to soak if heavily soiled. Dry filters and re-install before using hood.

‡

‡

Replacing Filters:

Should filters wear out due to age and prolonged use, please contact your local reseller for replacement filters.

Note: Also replace damaged filter that has punctured or broken mesh, bent or broken frame.

‡

Replacing the light bulb:

This range hood uses halogen bulb (please refer to the actual specification of the hood purchased):

USA/Canada:

35W Type MR16 12V / Type GU10 120V

Align arrows on both rings

Europe and other Countries:

‡

‡

‡

35W Type MR16 12V / Type GU10 220V

Make sure the range hood is unplugged or turn OFF breaker.

Make sure the lights are cool to touch, carefully align the ar

URZRQWKHLQQHUULQJZLWKWKHDUURZRQWKHRXWHUULQJZKHUHLW says OPEN. The inner ring will loosen and the light bulb will be available for removal. Install a new halogen light bulb and

UHYHUVHWKHVWHSV

Turn ON breaker and range hood to test for operation.

WARNING

Hazard of Burns!

Light bulb become extremely hot when turned on.

DO NOT touch bulb until switched off and cooled.

Touching hot bulbs could cause serious burns.

Page 17

Warranty

T O O B T A I N S E R V I C E U N D E R W A R R A N T Y :

Y u mu st p re se nt p ro of f o f f or i ig i in al l p ur h as e da te .

Pl ea se p ro vi i d a n or i ig i in al l d at t d p ro of f o f f pu rc ha se ( ( sa l le s re ce i ip t t / / i in vo i ic e) ) i i n or d r r t to o bt ai i n se rv i ic e un d r r wa rr an t y .

)LYH

Year Parts Warranty:

For

ILYH

year

V

from the date of original purchase, your local reseller will provide free of charge, non-consumable replace ment parts or components that failed due to manufacturing defects. Subject to the conditions and limitations set forth below, your local reseller will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. Repaired parts or replacement products will be provided by your local reseller on an exchange basis, and will be either new or refurbished to be functionally equivalent to new. The consumer is re sponsible for all shipping costs. Consumable parts not covered by this warranty include but not limited to: Light bulbs, metal, aluminum and charcoal filters.

Who is Covered:

This warranty is extended to the original purchaser for products purchased for ordinary home use.

This Warranty Will Be Voided When:

Product damaged through negligence, improper installation, accident, abuse, misuse, natural disaster, insufficient or excessive electrical supply, abnormal mechanical or environmental conditions, or any unauthorized disassembly, repair, modification, or failure to follow installation instructions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than your local reseller’s authorized agents. This limited warranty also does not apply to any product on which the original identification information has been altered, obliterated or removed, has not been handled or packaged correctly or has been sold as second-hand.

What is Not Covered:

Consumable parts such as light bulbs, metal and charcoal filters. The natural wear of finish, and wear due to improper maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products. Chips, dents or cracks due to abuse, misuse, freight damage, or improper installation. Damage of product caused by accident, fire, floods or act of God. The manufacturer and/or distributor/reseller is not liable for, and does not cover under warranty, any loss of properties or any costs associated with removing, servicing, installing, or determining the source of problems with this

SURGXFW

This warranty is valid in the country of the original purchase at retail. It is non-transferable and applies only to the original purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties, including the war ranty of merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.

To obtain warranty service, you may contact your local reseller from which you purchased this product. Please confirm the terms of your local reseller’s policies prior to contacting. Typically, you must include product identification information, including model number and serial number with a detailed description of the problem you are experiencing. You must also include proof of the date of original retail purchase as evidence that the product is within the applicable warranty period.

The information in this document is subject to change without notice, please contact your local reseller for updated details.

Page 18

Disclaimer

Carefully inspect all items for damages before accepting delivery. note any damages on the freight bill or express receipt. request name and signature of the carrier’s agent and keep copy to support your claim. Upon a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with

Damages caused during transit are not covered under our warranty

Please inspect contents of package(s) carefully upon receiving! W

" #"$ " days. NOTE: Items were thoroughly tested and carefully packed in our factory before shipping.

Products must be returned in good working condition with ALL original parts and documentation packed in

'<< = >? #@ merchandise is exchanged for items of equal or greater amount. Exchanges or returns may not be accepted if any packaging is missing.

Make sure to inspect the hood for damages and defects before installation.

-

Service visits not covered under warranty will carry a service charge.

Before Installation: Return for exchange or refund (please see above for acceptable returns).

After Installation:

NO

exchange or refund.

Contact Us

If you need any assistance, please contact Signature Hardware. Please have your order number and model of the range hood ready. This information will help us better respond to your request.

If you need replacement parts, we recommend that you only use genuine parts. Our accessories and parts are in durability and reliability, providing a factory match, factory-installed appearance and functionality tailored to each individual range hood model.

Contact Signature Hardware Customer Service :

>X[\\X[X]][^

_ X`{[{?? >>{??

|{[{?? }{??

~{[{?? {?

Sunday - closed

The information in this document is

=

to change without notice, please contact us f or updated details.

Page

Your Notes

Page 20

Your Notes

3DJH

21

advertisement

Related manuals