Datalogic MAGELLAN 3200VSI Product Reference Manual


Add to my manuals
212 Pages

advertisement

Datalogic MAGELLAN 3200VSI Product Reference Manual | Manualzz

Magellan

TM

3200VSi

On-Counter Vertical Presentation Scanner

Product Reference Guide

Datalogic Scanning, Inc.

959 Terry Street

Eugene, Oregon 97402

USA

Telephone: (541) 683-5700

Fax: (541) 345-7140

An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.

Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.

Disclaimer

Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice.

Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other brand and product names may be trademarks of their respective owners.

Magellan is a registered trademark of Datalogic Scanning, Inc. in many countries, including the U.S.A. and the E.U.

This product may be covered by one or more of the following patents: US5179270 • US5837983 • US6705527 • US6729603 • US6758403 • US6877663 • US7108170 •

US7234641 • US7299975

Table of Contents

Chapter 3. Getting Started............................................................................................................................................................... 1

About This Manual ...........................................................................................................................................................................................................1

Manual Conventions ................................................................................................................................................................................................... 1

Connecting the Scanner ................................................................................................................................................................................................2

Error Codes ..........................................................................................................................................................................................................................4

Mount Installation ............................................................................................................................................................................................................4

Wall Mount ..................................................................................................................................................................................................................... 6

Countertop Mount ....................................................................................................................................................................................................... 6

LED and Beeper Indicators ............................................................................................................................................................................................7

Programming .....................................................................................................................................................................................................................8

Using the Programming Bar Codes ....................................................................................................................................................................... 8

Resetting the Standard Product Defaults ...............................................................................................................................................................8

Data Matrix Programming Labels ..............................................................................................................................................................................8

Bar Code Mask ...................................................................................................................................................................................................................9

Going Green .................................................................................................................................................................................................................10

LED Class ........................................................................................................................................................................................................................... 10

Chapter 4. General Features .......................................................................................................................................................... 11

Double Read Timeout for Linear Labels ................................................................................................................................................................ 11

Double Read Timeout for 2D Labels ...................................................................................................................................................................... 13

Scanner Button Options .............................................................................................................................................................................................. 14

Camera Button Mode ................................................................................................................................................................................................... 15

Auto Cell Phone Mode ................................................................................................................................................................................................. 16

Auto Cell Phone Mode Enable ...............................................................................................................................................................................16

LED Level ........................................................................................................................................................................................................................... 17

Auxiliary Port Mode ...................................................................................................................................................................................................... 18

Auxiliary Port Baud Rate ............................................................................................................................................................................................. 19

Productivity Index Reporting (PIR) .......................................................................................................................................................................... 20

Sleep Mode ...................................................................................................................................................................................................................... 21

LED and Beeper Indicators ......................................................................................................................................................................................... 23

Power On Alert ............................................................................................................................................................................................................23

External Read Indicator (ERI) Active State High ..............................................................................................................................................23

ERI Timeout ..................................................................................................................................................................................................................24

Good Read: When to Indicate ................................................................................................................................................................................25

Good Read Beep Control .........................................................................................................................................................................................26

Good Read Beep Frequency ...................................................................................................................................................................................26

Good Read Beep Length ..........................................................................................................................................................................................27

Good Read Beep Volume ........................................................................................................................................................................................28

Scanning Features ......................................................................................................................................................................................................... 29

Wake Up Intensity ......................................................................................................................................................................................................29

Chapter 5. Image Capture .............................................................................................................................................................. 31

Image Capture ................................................................................................................................................................................................................ 31

How to Capture an Image .......................................................................................................................................................................................31

Image Capture to a microSD Card by Scanning a Special Label ....................................................................................................31

Image Capture to the Host by Host Command .....................................................................................................................................32

Image Compression ...................................................................................................................................................................................................... 33

Image Format .................................................................................................................................................................................................................. 33

Image Size ........................................................................................................................................................................................................................ 34

Image Brightness ........................................................................................................................................................................................................... 35

Image Contrast ............................................................................................................................................................................................................... 35

Chapter 6. Interface Related Features .......................................................................................................................................... 37

Interface Selection ........................................................................................................................................................................................................ 39

Interface Features .......................................................................................................................................................................................................... 41

Obey/Ignore Host Commands .....................................................................................................................................................................41

Host Transmission Buffers .............................................................................................................................................................................42

RS-232 Interface Features .......................................................................................................................................................................................43

Hardware Flow Control ..................................................................................................................................................................................45

Product Reference Guide i

Intercharacter Delay ........................................................................................................................................................................................ 46

Software Flow Control .................................................................................................................................................................................... 47

Host Echo ............................................................................................................................................................................................................ 48

Host Echo Quiet Interval ................................................................................................................................................................................ 49

Signal Voltage: Normal/TTL .......................................................................................................................................................................... 50

RS-232 Invert ...................................................................................................................................................................................................... 51

Beep on ASCII BEL ............................................................................................................................................................................................ 51

Beep on Not on File ......................................................................................................................................................................................... 52

ACK NAK Options ............................................................................................................................................................................................. 53

ACK Character .................................................................................................................................................................................................... 54

NAK Character ................................................................................................................................................................................................... 54

Retry on ACK NAK Timeout .......................................................................................................................................................................... 55

ACK NAK Timeout Value ................................................................................................................................................................................ 55

ACK NAK Retry Count ..................................................................................................................................................................................... 56

ACK NAK Error Handling .......................................................................................................................................................................................... 57

Transmission Failure Indication .................................................................................................................................................................. 58

Single Cable RS-232 ......................................................................................................................................................................................................58

Single Cable RS-232 Options ................................................................................................................................................................................. 58

Single Cable RS-232 RTS CTS Selection .............................................................................................................................................................. 59

Single Cable RS-232 Use BCC ................................................................................................................................................................................. 60

Single Cable RS-232 Use ACK/NAK ...................................................................................................................................................................... 60

Single Cable RS-232 Use STX ................................................................................................................................................................................. 61

Set Single Cable RS-232 STX Character .............................................................................................................................................................. 61

Single Cable RS-232 Use ETX ................................................................................................................................................................................. 62

Set Single Cable RS-232 ETX Character .............................................................................................................................................................. 62

Single Cable Pacesetter Plus .................................................................................................................................................................................. 63

Single Cable Datalogic Extensions ...................................................................................................................................................................... 63

USB-OEM Interface Features .................................................................................................................................................................................. 64

USB-OEM Device usage ................................................................................................................................................................................. 64

IBM .................................................................................................................................................................................................................................. 64

IBM Transmit Labels in Code 39 Format .................................................................................................................................................. 64

Keyboard Wedge ....................................................................................................................................................................................................... 65

USB Keyboard .............................................................................................................................................................................................................. 65

Caps Lock State ................................................................................................................................................................................................. 67

USB COM Interface Set-up ..........................................................................................................................................................................................71

Chapter 7. Data Editing.................................................................................................................................................................. 73

Data Editing Overview .................................................................................................................................................................................................73

Please Keep In Mind... ............................................................................................................................................................................................... 73

Global Prefix/Suffix ........................................................................................................................................................................................................74

AIM ID .................................................................................................................................................................................................................................76

Label ID ..............................................................................................................................................................................................................................77

Case Conversion .............................................................................................................................................................................................................84

Character Conversion ...................................................................................................................................................................................................85

Chapter 8. Symbologies................................................................................................................................................................. 87

UPC-A ..................................................................................................................................................................................................................................87

Disable/Enable UPC-A .............................................................................................................................................................................................. 87

Check Digit Transmission ........................................................................................................................................................................................ 88

Number System Transmission .............................................................................................................................................................................. 88

Expand UPC-A to EAN-13 ........................................................................................................................................................................................ 89

UPC-E ..................................................................................................................................................................................................................................90

Disable/Enable UPC-E .............................................................................................................................................................................................. 90

Check Digit Transmission ........................................................................................................................................................................................ 90

Number System Digit ............................................................................................................................................................................................... 91

Expand to UPC-E to UPC-A ..................................................................................................................................................................................... 91

Expand UPC-E to EAN13 .......................................................................................................................................................................................... 92

GTIN ................................................................................................................................................................................................................................ 93

Expand UPC/EAN to GTIN ....................................................................................................................................................................................... 93

EAN-13 ................................................................................................................................................................................................................................94

Disable/Enable EAN-13 ............................................................................................................................................................................................ 94

Check Digit Transmission ........................................................................................................................................................................................ 94

ii

Magellan TM

3200VSi

EAN-13 Flag 1 Character ..........................................................................................................................................................................................95

ISBN .................................................................................................................................................................................................................................95

EAN-8 .................................................................................................................................................................................................................................. 96

Disable/Enable EAN-8 ...............................................................................................................................................................................................96

Check Digit Transmission ........................................................................................................................................................................................96

EAN Two-Label ............................................................................................................................................................................................................... 98

EAN Two-Label Combined Transmission ............................................................................................................................................................. 98

Price Weight Check Digit ............................................................................................................................................................................................ 99

Add-ons ...........................................................................................................................................................................................................................100

GS1 DataBar Omnidirectional / Stacked Omnidirectional ...........................................................................................................................102

Disable/Enable GS1 DataBar Omnidirectional ............................................................................................................................................. 102

UCC/EAN 128 Emulation ...................................................................................................................................................................................... 102

GS1 DataBar Expanded / Expanded Stacked ....................................................................................................................................................103

Disable/Enable GS1 DataBar Expanded .......................................................................................................................................................... 103

GS1-128 Emulation ................................................................................................................................................................................................. 103

Length Control ......................................................................................................................................................................................................... 104

GS1 DataBar Expanded Length 1, Length 2 Programming Instructions ............................................................................................. 105

Coupon Read Control ............................................................................................................................................................................................ 106

GS1 DataBar Limited ..................................................................................................................................................................................................107

Disable/Enable GS1 DataBar Limited ............................................................................................................................................................... 107

GS1-128 Emulation ................................................................................................................................................................................................. 107

Code 39 ...........................................................................................................................................................................................................................108

Disable/Enable Code 39 ........................................................................................................................................................................................ 108

Check Character Calculation ............................................................................................................................................................................... 108

Check Character Transmit .................................................................................................................................................................................... 109

Start/Stop Characters ............................................................................................................................................................................................ 109

Code 39 Full ASCII ................................................................................................................................................................................................... 110

Length Control ......................................................................................................................................................................................................... 111

Code 39 Length 1, Length 2 Programming Instructions .......................................................................................................................... 112

Code 32 Italian Pharmacode ...................................................................................................................................................................................113

Disable/Enable Code 32 Italian Pharmacode ................................................................................................................................................ 113

Start/Stop Characters ............................................................................................................................................................................................ 113

Code 32 Italian Pharmacode — continued ................................................................................................................................................... 114

Check Character Transmit .................................................................................................................................................................................... 114

Code 128 .........................................................................................................................................................................................................................115

Disable/Enable Code 128 ..................................................................................................................................................................................... 115

Disable/Enable EAN 128 ....................................................................................................................................................................................... 115

Transmit Function Characters ............................................................................................................................................................................ 116

Length Control ......................................................................................................................................................................................................... 117

Code 128 Length 1, Length 2 Programming Instructions ........................................................................................................................ 118

Code 128 Conversion to Code 39 ...................................................................................................................................................................... 118

Interleaved 2 of 5 .........................................................................................................................................................................................................119

Disable/Enable Interleaved 2 of 5 ..................................................................................................................................................................... 119

Check Digit Calculation ......................................................................................................................................................................................... 119

Check Digit Transmit .............................................................................................................................................................................................. 120

Length Control ......................................................................................................................................................................................................... 121

Interleaved 2 of 5 Length 1, Length 2 Programming Instructions ........................................................................................................ 122

Codabar ...........................................................................................................................................................................................................................123

Disable/Enable Codabar ....................................................................................................................................................................................... 123

Check Character Verification ............................................................................................................................................................................... 123

Check Character Transmit .................................................................................................................................................................................... 124

Length Control ......................................................................................................................................................................................................... 125

Codabar Length 1, Length 2 Programming Instructions .......................................................................................................................... 126

Start/Stop Character Type .................................................................................................................................................................................... 127

Start/Stop Character Transmission ................................................................................................................................................................... 127

Start/Stop Character Match ................................................................................................................................................................................. 128

Code 93 ...........................................................................................................................................................................................................................129

Disable/Enable Code 93 ........................................................................................................................................................................................ 129

Length Control ......................................................................................................................................................................................................... 130

Code 93 Length 1, Length 2 Programming Instructions .......................................................................................................................... 131

Chapter 9. 2D Symbologies ......................................................................................................................................................... 133

Product Reference Guide iii

2D Symbologies ........................................................................................................................................................................................................... 133

PDF 417 ........................................................................................................................................................................................................................134

Disable/Enable PDF 417 ...............................................................................................................................................................................134

Length Control ................................................................................................................................................................................................135

PDF 417 Length 1, Length 2 Programming Instructions .................................................................................................................136

Micro PDF 417 ...........................................................................................................................................................................................................137

Disable/Enable Micro PDF 417 ..................................................................................................................................................................137

Length Control ................................................................................................................................................................................................138

Micro PDF 417 Length 1, Length 2 Programming Instructions .....................................................................................................139

Datamatrix ..................................................................................................................................................................................................................140

Disable/Enable Datamatrix .........................................................................................................................................................................140

Length Control ................................................................................................................................................................................................141

Datamatrix Length 1, Length 2 Programming Instructions ............................................................................................................142

QR Code .......................................................................................................................................................................................................................143

Disable/Enable QR Code ..............................................................................................................................................................................143

Length Control ................................................................................................................................................................................................144

QR Code Length 1, Length 2 Programming Instructions ................................................................................................................145

Maxicode .....................................................................................................................................................................................................................146

Disable/Enable Maxicode ............................................................................................................................................................................146

Length Control ................................................................................................................................................................................................147

Maxicode Length 1, Length 2 Programming Instructions ..............................................................................................................148

Aztec .............................................................................................................................................................................................................................149

Disable/Enable Aztec ....................................................................................................................................................................................149

Length Control ................................................................................................................................................................................................150

Aztec Length 1, Length 2 Programming Instructions .......................................................................................................................151

Composite Labels ....................................................................................................................................................................................................152

Disable/Enable GS1 DataBar Omnidirectional 2D Component ....................................................................................................152

Disable/Enable GS1 DataBar Expanded 2D Component .................................................................................................................152

Disable/Enable GS1 DataBar Limited 2D Component ......................................................................................................................153

Chapter 10. Advanced Decoding Features................................................................................................................................. 155

Inverse Label Reading ............................................................................................................................................................................................... 155

Optical and Read Performance Parameters ...................................................................................................................................................... 157

Scanner Dimensions .................................................................................................................................................................................................. 157

Physical Properties ..................................................................................................................................................................................................... 158

Electrical Parameters ................................................................................................................................................................................................. 158

Environmental Parameters ...................................................................................................................................................................................... 158

Other Parameters ........................................................................................................................................................................................................ 158

Standard Cable Pinouts (Primary Interface Cables) ....................................................................................................................................... 159

Factory Defaults by Interface .................................................................................................................................................................................. 163

............................................................................................................................................................................................................................................ 168

Keyboard Model Cross Reference ......................................................................................................................................................................... 169

Accepting RS-232 Commands ............................................................................................................................................................................... 177

1D Symbol Samples ................................................................................................................................................................................................... 179

2D Sample Symbols ................................................................................................................................................................................................... 181

Composite Sample Symbols ................................................................................................................................................................................... 182

microSDHC Compatibility ........................................................................................................................................................................................ 183 microSD Card Insertion/Removal Indication .................................................................................................................................................... 183

Autorun File Processing ............................................................................................................................................................................................ 183

microSD Function Summary ................................................................................................................................................................................... 184 microSD Function Details ........................................................................................................................................................................................ 184

From Scanner to microSD Card ..........................................................................................................................................................................184

Capture and save an image to a micro SD card by scanning a label. ..........................................................................................184

Export a Configuration file from the Scanner to the micro SD card ............................................................................................185

Export Scanner Status to microSD card .................................................................................................................................................185

From microSD Card to Scanner ..........................................................................................................................................................................186

Application code load to scanner ............................................................................................................................................................186

CPLD code load to the scanner .................................................................................................................................................................186

Configuration load to scanner ..................................................................................................................................................................187

Handheld Data Format Requirements General ............................................................................................................................................189

Datalogic Handheld Data Format Requirements .........................................................................................................................................190

RSS-14 .................................................................................................................................................................................................................190

iv

Magellan TM

3200VSi

RSS Expanded ................................................................................................................................................................................................. 190

UPC-A ................................................................................................................................................................................................................. 190

UPC-A with 2-Digit Supplemental ........................................................................................................................................................... 190

UPC-A with 5-Digit Supplemental ........................................................................................................................................................... 190

UPC-A with Code 128 Supplemental ..................................................................................................................................................... 190

UPC-E ................................................................................................................................................................................................................. 191

UPC-E with 2-Digit Supplemental ........................................................................................................................................................... 192

UPC-E with 5-Digit Supplemental ........................................................................................................................................................... 192

UPC-E with Code 128 Supplemental ...................................................................................................................................................... 192

EAN-8 ................................................................................................................................................................................................................. 193

EAN-8 with 2-Digit Supplemental ........................................................................................................................................................... 193

EAN-8 with 5-Digit Supplemental ........................................................................................................................................................... 193

EAN-8 with Code 128 Supplemental ...................................................................................................................................................... 193

EAN-13 ............................................................................................................................................................................................................... 193

EAN-13 with 2-Digit Supplemental ......................................................................................................................................................... 193

EAN-13 with 5-Digit Supplemental ......................................................................................................................................................... 193

EAN-13 with Code 128 Supplemental ................................................................................................................................................... 194

Code 39 ............................................................................................................................................................................................................. 194

Code 39-Pharmacode .................................................................................................................................................................................. 194

I 2 of 5 ................................................................................................................................................................................................................. 194

Codabar ............................................................................................................................................................................................................. 195

Code 128 ........................................................................................................................................................................................................... 195

MSI/Plessey ...................................................................................................................................................................................................... 196

Code 93 ............................................................................................................................................................................................................. 196

PDF417 .............................................................................................................................................................................................................. 196

AIM Formats .............................................................................................................................................................................................................. 197

UPC-A ................................................................................................................................................................................................................. 197

UPC-E ................................................................................................................................................................................................................. 197

EAN-13 ............................................................................................................................................................................................................... 197

EAN-8 ................................................................................................................................................................................................................. 197

2-Digit Supplemental ................................................................................................................................................................................... 197

5-Digit Supplemental ................................................................................................................................................................................... 198

Code 128 Supplemental ............................................................................................................................................................................. 199

Bookland ........................................................................................................................................................................................................... 199

Code 39 ............................................................................................................................................................................................................. 199

Codabar ............................................................................................................................................................................................................. 199

MSI/Plessey ...................................................................................................................................................................................................... 200

Code 93 ............................................................................................................................................................................................................. 200

RSS-14 ................................................................................................................................................................................................................ 201

RSS Expanded ................................................................................................................................................................................................. 201

I 2 of 5 ................................................................................................................................................................................................................. 201

Code 128 / EAN128 ....................................................................................................................................................................................... 202

PDF417 .............................................................................................................................................................................................................. 202

“Unknown” AIM ID (an AIM ID which is not specified above) ...................................................................................................... 202

Product Reference Guide v

NOTES vi

Magellan TM

3200VSi

Chapter 3

Getting Started

The Magellan

TM

3200VSi On-Counter Vertical Presentation Scanner is designed for small counter retail checkout environments where there is a relatively high number of transactions with a fairly small number of items per transaction. The scanner has a reduced footprint, allowing more room for item merchandising of high margin impulse items clustered around the

P.O.S.

About This Manual

This manual provides advanced user information, including connection, programming, product and cable specifications, and other useful references. For additional information, such as installation, maintenance, troubleshooting and warranty information, see the Quick Reference Guide

(QRG). Copies of other publications for this product are downloadable free of charge from the website listed on the back cover of this manual.

On leaving the factory, units are programmed for the most common terminal and communications settings. If you need to change these settings, custom programming can be accomplished by scanning the bar codes in this guide.

Bold text and a yellow-highlighted background indicates the most common default setting for a feature/option.

Manual Conventions

The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the scanner:

Notes contain information necessary for properly diagnosing, repairing and operating the scanner.

NOTE

CAUTION

The CAUTION symbol advises you of actions that could damage equipment or property.

1

Product Reference Guide

Getting Started

Connecting the Scanner

The scanner kit you ordered to match your interface should provide a compatible cable for your installation. Alternatively, if your scanner receives Power Off the Terminal (POT) it might be possible to connect using a cable from a previously existing installation (except for USB). If you wish to connect using an existing cable, but cannot use POT, a short adapter cable is available.

Check with your technical support representative about compatibility before connecting. Use the appropriate instructions below when you’re ready to connect the scanner to the terminal, PC or other host device.

Upon completing the connection via the appropriate interface instructions below, proceed to the

Interface Related Features

section of this manual and scan the bar code to select the correct interface type.

RS-232 Serial Connection — Turn off power to the terminal/PC and connect the scanner to the

terminal/PC serial port via the RS-232 cable as shown in Figure 1 a. If the terminal will not sup-

port POT (Power Off the Terminal) to supply scanner power, use the approved power supply

(AC Adapter) as shown in

Figure 1

b. Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet.

Figure 1 . Connecting the Scanner a

Terminal (PC) b Keyboard Wedge, RS-232 and USB Cables

Powered by AC Adapter

To Terminal (PC)

R

S

-2

32

U

S

B or...

Power Off the Terminal

(POT) or...

IB

M

RS

-2

3

2

US

B

Keyboard

Wedge c Other Non-POT Cables

Powered by AC Adapter via short adapter cable

To Terminal (PC)

USB Connection — Connect the scanner to a USB port on the terminal/PC using the correct

USB cable for the interface type you ordered. Reference Figure 1

.

NOTE

USB installations may require a power connection via an approved A/C

Adapter as shown in

Figure 1

b or

Figure 1

c. For example, this would be the case if the scanner is connected along with a number of other devices to a non-powered USB hub.

IBM Connection — Connect the scanner to the IBM port on the terminal/PC using the correct

IBM cable. Reference

Figure 1 .

2

Magellan TM 3200VSi

Connecting the Scanner

Keyboard Wedge Connection — Before connection, turn off power to the terminal/PC. The Keyboard Wedge cable has a ‘Y’ connection from the scanner. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference

Figure 1 a.

Figure 2. Labeling and Nomenclature

1

2

3

4

5 6

7

8

9 10 11

12

13

1

2

3

4

5

Back Cover

Scanner Push Button

Camera Push Button

Scan Window

Cable Connector Cover

6

Checkpoint EAS Wire Cavity

Electrical Article Surveillance

Antenna Connection

7 Serial Number/Regulatory Label

8 P/N Label

9 USB/SD Cover

10

USB Service Port — On Screen Programming

Tool

11

12 microSD Card Slot — Upgrade, imaging, statistics data

Host (blue) Port— POS terminal, label data, application host download, host commands to scanner

13

Auxiliary (yellow) Port for RS-232 handheld scanner, EAS Interlock, PIR data, etc.

Product Reference Guide

3

Getting Started

Error Codes

If an error is detected, the scanner will sound a long low tone (for three seconds) and flash its

LED, indicating a failure. When this occurs, press the Scanner Pushbutton to hear the error code. If it is configured to do so, the scanner will sound a series of beeps corresponding to the error code and/or flash its LED simultaneous to the beeps. The table below describes what these codes mean and what action should be taken for each.

NUMBER OF

LED FLASHES/

BEEPS

12

13

14

6

10

1

2

ERROR

Configuration

Interface PCB

Main PCB

Button Error

Imager Module

Software ID Failure

Software Fatal Fault

CORRECTIVE ACTION

Contact Helpdesk for assistance

Mount Installation

Options for mounting the scanner to a wall or countertop include an L-Bracket or stackable

Risers (straight or tilted).

Figure 3

shows the scanner being seated in an L-Bracket.

Figure 4 dem-

onstrates the use of stackable Risers.

Stackable Risers also require use of the L-Bracket in order to securely seat the scanner in the topmost riser.

NOTE

4

Magellan TM 3200VSi

Figure 3. L-Bracket Mount

1

Mount Installation

3

4

5

2

1. Scanner

2. L-Bracket

3. Wall Mounting Screws

4. Countertop Mounting Screws

5. Move the scanner toward the bracket in a diagonal motion to seat it.

Product Reference Guide

5

Getting Started

Figure 4. Using the Risers

6 a

One Riser b

Two Risers stacked. Scanner and

L-Bracket have been tilted on the top Riser.

Wall Mount

Attach the L-Bracket to the wall, securing it in the desired position with two screws through the two holes in the back face of the L-Bracket as shown in

Figure 3

. Recommendation: Use two Pan

Head (8.2mm or 5/16” maximum head diameter) #8 screw with a thread profile that suits the mounting surface material in the wall.

Countertop Mount

If using the L-Bracket alone for countertop installation, secure the bracket in place using two screws through the bottom face of the bracket (see

Figure 3

). If risers are used, secure a riser to the countertop by attaching two screws through its screw holes. Recommendation: Use two Pan

Head (8.2mm or 5/16” maximum head diameter) #8 screw with a thread profile that suits the mounting surface material in the countertop.

Do not use a countersink type of screw head. Damage will occur from use of a countersunk screw head in the plastic screw bosses

CAUTION

Risers may be stacked as shown in

Figure 4

b. Each riser increments the height of the mounted scanner by 1.5” (38.1mm). Riser pieces readily snap together or apart and allow for adjustable tilt of the scanner/L-Bracket of up to 20 degrees in 5° increments.

Figure 4

b provides an example of a tilted scanner.

Magellan TM 3200VSi

LED and Beeper Indicators

LED and Beeper Indicators

The scanner’s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner. The tables below list these indications. One exception to the behaviors listed in the tables is that the scanner’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming bar code labels.

Green LED Indications

LED

INDICATION

INDICATION COMMENT

Power-on indication

Good Read

Indication

Bright green flash

Bright green flash

Indicates the scanner has finished all its power up tests and is now ready for operation.

Indicates a bar code has been read and decoded.

Scanner Ready

Sleep Mode

Host Disable

Diagnostics

Prog. Mode

Constant dim green

Green LED slowly and continuously changes from off to dim to off.

Constant green flash at 1 Hz

(100mS on, 900mS off)

Varies (see "Error Codes"

Host Disable above.

on page 3-4 for more information)

See

The scanner is ready for operation. The LED is also configurable to off when idle and ready for operation

The scanner is in Sleep Mode. To wake the scanner up, move an object in front of its window or press the button atop the unit. This indication is optionally configurable and may have been programmed to behave differently.

The scanner is disabled due to receiving a disble command from the POS terminal.

The LED can provide diagnostic feedback if the scanner discovers a problem during SelfTest.

The scanner is in Programming Mode.

BEEPER FUNCTIONS

BEEPER

INDICATION

INDICATION COMMENT

Power On Beep Single beep

Good Read

Indication

Diagnostics

Single beep

Varies (see "Error Codes" on page 3-4 for more information)

The Power-On Beep indication is a configurable feature which can be enabled or disabled. When enabled, this beep Indicates the scanner has finished all its power up tests and is now ready for operation.

The good read beep indication is configurable. Options include: Enable/disable, frequency, duration and volume. See the Product Reference Guide (PRG) for more information.

The Beeper can provide diagnostic feedback if the scanner discovers a problem during SelfTest.

Product Reference Guide

7

Getting Started

BEEPER FUNCTIONS

BEEPER

INDICATION

Programming

Mode

Indications

INDICATION

Varies depending upon the feature(s) being configured.

COMMENT

The Beeper will sound as programming bar code labels are scanned, indicating progress during scanner configuration.

Programming

The scanner is typically factory-configured with a set of default features standard to the interface

type you ordered. After scanning the interface bar code from the Interface Related Features sec-

tion, you can select other options and customize your scanner through use of the instructions and programming bar codes available in that section and also the

Data Editing

and

Symbologies

chapters of this manual.

Using the Programming Bar Codes

This manual contains feature descriptions and bar codes which allow you to reconfigure your scanner. Some programming bar code labels, like the label below for resetting defaults, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the scanner to be placed in Programming Mode prior to scanning them. Scan a START/END bar code once to enter Programming Mode. Once the scanner is in

Programming Mode, you can scan a number of parameter settings before scanning the START/

END bar code a second time, which will then accept your changes, exit Programming Mode and return the scanner to normal operation.

Resetting the Standard Product Defaults

If you are unsure of what programming options are in your scanner, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings bar code below. This will copy the factory configuration for the currently active interface to the current configuration.

Standard Product Default Settings

The programming section lists the factory default settings for each of the menu commands for the standard RS-232 interface in BOLD text on the following pages. Exceptions to default settings for the other interfaces can be found in

Appendix D, Factory Default Settings

.

Data Matrix Programming Labels

Some scanners can be configured using Data Matrix programming labels. This feature is ONLY available for scanners with 2D capability.

Contact Technical Support to request Data Matrix programming labels.

8

Magellan TM 3200VSi

Bar Code Mask

Bar Code Mask

Cut a hole in this page and remove it from the manual as indicated to create a sleeve through which bar codes (starting in the following section) can be individually viewed and scanned. It is important that only one bar code at a time be presented to the scanner.

1

2

3

1. Bar Code Mask Sheet

2. Bar Code

3. Manual (folded)

Product Reference Guide

9

Getting Started

Going Green

Thank you for using the bar code mask on the opposite side of this page. This manual has been formatted to minimize the quantity of pages needed to provide all of the programming bar codes available for this product.

LED Class

CLASS 1 LED PRODUCT APPARECCHIO LED CLASSE 1

LED KLASSE 1 APPAREIL A LED DE CLASSE 1

IEC / EN 60825-1:2007

Max output of LED radiation: 3.21mW per pulse at 100mm

Pulse duration: 200µs

Emitted wavelength 625nm

10

Magellan TM 3200VSi

Chapter 4

General Features

Double Read Timeout for Linear Labels

This Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same linear label again (e.g. two identical items in succession).

START / END

PROGRAMMING bar codes

0.1 Second

0.2 Second

0.3 Second

0.4 Second

0.5 Second

0.6 Second

DEFAULT

11

Product Reference Guide

General Features

Double Read Timeout for Linear Labels — cont.

PROGRAMMING bar code

0.7 Second

START / END

0.8 Second

0.9 Second

1 Second

12

Magellan TM 3200VSi

Double Read Timeout for 2D Labels

Double Read Timeout for 2D Labels

This Double Read Timeout feature specifies the minimum allowable time between consecutive good reads of the same PDF 417, Micro PDF 417 Data Matrix, QR Code, Maxicode, Aztec or

Composite label.

START / END

PROGRAMMING bar codes

1 Second

DEFAULT

1.5 Seconds

1.65 Seconds

1.8 Seconds

1.95 Seconds

2 Seconds

2.55 Seconds

Product Reference Guide

13

General Features

Scanner Button Options

This feature allows the user to configure the scanner (volume) button to different modes of operation.

Options are:

• All functions (volume, tone, diagnostics, and reset)

• Enable only volume, tone, and reset

• Enable reset only

• Disable all button functions

START / END

Scanner Button Options = All functions

PROGRAMMING bar codes

Scanner Button Options =

Enable only volume, tone, and reset

DEFAULT

Scanner Button Options = Enable reset only

Scanner Button Options = Disable all button functions

14

Magellan TM 3200VSi

Camera Button Mode

Controls the function associated with the "Picture Taking" button

Options are:

• Normal Take Picture operation

• Activates Cell Phone Toggle Mode when not taking picture

• Activates Cell Phone One-Shot Mode when not taking pictures

START / END

PROGRAMMING bar codes

Camera Button Mode = Normal Take Picture operation

DEFAULT

Camera Button Mode

Camera Button Mode =

Activates Cell Phone Toggle Mode when not taking picture

Camera Button Mode =

Activates Cell Phone One-Shot Mode when not taking pictures

Product Reference Guide

15

General Features

Auto Cell Phone Mode

Auto Cell Phone Mode enables the scanner to read bar codes on a cell phone display without user intervention. For high ambient light conditions, button cell phone mode is recommended.

(See “Camera Button Mode” on page 15.)

Auto Cell Phone Mode Enable

Enables/disables Auto Cell Phone Mode.

START / END

PROGRAMMING bar codes

Auto Cell Phone Mode = Disable

DEFAULT

Auto Cell Phone Mode = Enable Normal

Auto Cell Phone Mode = Enable Sensitive

Auto Cell Phone Mode = Enable Sensitive Ambient

16

Magellan TM 3200VSi

LED Level

This feature defines the LED intensity level by pulse width.

START / END

PROGRAMMING bar codes

LED Level = Medium

DEFAULT

LED Level = Low

LED Level = High

LED Level

Product Reference Guide

17

General Features

Auxiliary Port Mode

Specifies the function associated with the auxillary interface.

Choices are:

• Disabled

• 01=Serial Handheld Enabled

• 02=PIR/CT Output plus Diagnostics Reporting

START / END

PROGRAMMING bar codes

Disable Auxiliary Port Mode

DEFAULT

Auxiliary Port Mode = Serial Handheld Enabled

Auxiliary Port Mode = PIR/CT Output plus Diagnostics Reporting

18

Magellan TM 3200VSi

Auxiliary Port Baud Rate

Specifies baud rate of auxillary port when operating in PIR/CT mode.

START / END

PROGRAMMING bar codes

Auxiliary Port Baud Rate = 1200

Auxiliary Port Baud Rate

Auxiliary Port Baud Rate = 2400

Auxiliary Port Baud Rate = 4800

Auxiliary Port Baud Rate = 9600

Auxiliary Port Baud Rate = 19200

DEFAULT

Auxiliary Port Baud Rate = 38400

Auxiliary Port Baud Rate = 57600

Auxiliary Port Baud Rate = 115200

Product Reference Guide

19

General Features

Productivity Index Reporting (PIR)

When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer, indicating how easy the label was to read.

This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability.

NOTE

START / END

PROGRAMMING bar codes

Disable

DEFAULT

Enable

20

Magellan TM 3200VSi

Sleep Mode

Sleep Mode

This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode.

START / END

PROGRAMMING bar codes

Disable Sleep Mode

15 Seconds

30 Seconds

1 Minute

2 Minutes

3 Minutes

4 Minutes

5 Minutes

DEFAULT

Product Reference Guide

21

General Features

Sleep Mode — cont.

START / END

PROGRAMMING bar codes

6 Minutes

7 Minutes

8 Minutes

9 Minutes

10 Minutes

DEFAULT

12 Minutes

15 Minutes

30 Minutes

1 Hour

22

Magellan TM 3200VSi

LED and Beeper Indicators

LED and Beeper Indicators

Power On Alert

Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation.

START / END

PROGRAMMING bar codes

Disable

Enable

DEFAULT

External Read Indicator (ERI) Active State High

This feature is available only through use of a special cable.

NOTE

START / END

PROGRAMMING bar codes

ERI Active State = High

ERI Active State = Low

DEFAULT

Product Reference Guide

23

General Features

ERI Timeout

Specifies the amount of time the External Read Indicator (ERI) signal is held active for a good read.

START / END

PROGRAMMING bar codes

Sets the ERI timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ERI Timeout,” followed by the two digits (zero padded) from the Alphanumeric table in

Appendix C, Alpha-Numeric Pad

representing the desired time value. Exit programming mode by scanning the “START/END” bar code again.

DEFAULT SETTING FOR THIS FEATURE: 20 milliseconds (02)

Set ERI Timeout

24

Magellan TM 3200VSi

LED and Beeper Indicators

Good Read: When to Indicate

This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are:

• Good Read = Indicate after decode

• Good Read = Indicate after transmit

• Good Read = Indicate after CTS goes inactive, then active

This option (Indicate after CTS goes inactive, then active), which uses CTS, is only valid for RS-232 interfaces.

NOTE

START / END

PROGRAMMING bar codes

After Decode

DEFAULT

After Transmit

³

After CTS goes inactive, then active

Product Reference Guide

25

General Features

Good Read Beep Control

This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code.

START / END

PROGRAMMING bar codes

Disable

Enable

DEFAULT

Good Read Beep Frequency

Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)

START / END

PROGRAMMING bar codes

Low

Medium

DEFAULT

High

26

Magellan TM 3200VSi

Good Read Beep Length

Specifies the duration of a good read beep.

PROGRAMMING bar codes

60msec

START / END

LED and Beeper Indicators

80msec

DEFAULT

100msec

120msec

140msec

160msec

180msec

200msec

Product Reference Guide

27

General Features

Good Read Beep Volume

Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.

START / END

PROGRAMMING bar codes

Low

Medium

High

DEFAULT

28

Magellan TM 3200VSi

Scanning Features

Scanning Features

Wake Up Intensity

This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode. Lower settings provide greater sensitivity. The selectable range for this setting is 5% to 15%.

START / END

PROGRAMMING bar codes

5%

6%

7%

8%

9%

10%

DEFAULT

11%

12%

Product Reference Guide

29

General Features

Wake Up Intensity — cont.

PROGRAMMING bar codes

START / END

13%

14%

15%

30

Magellan TM 3200VSi

Chapter 5

Image Capture

Image Capture

How to Capture an Image

There are two methods of capturing images as discussed below:

Image Capture to a microSD Card by Scanning a Special Label

Image Capture to the Host by Host Command

Image Capture to a microSD Card by Scanning a Special Label

Insert a micro SD card into the scanner, scan a capture label and place the item to be captured in front of the scanner. Press and release the Camera Button. The image will be written to the micro SD card five seconds after button release.

The format, size, contrast, brightness and compression use the configured values.

This Capture label is as follows:

<FNC3>IMAGEFAUTO<CR>

The Capture label will not read unless a microSD card is inserted.

NOTE

The image filename is automatically increased from image000 to image999.

The date image file generated is not actual, since no real time clock is embedded in the scanner.

31

Product Reference Guide

Image Capture

Image Capture to the Host by Host Command

This feature is only available for RS-232 and USB COM interfaces.

If the USB COM interface has been selected, follow the

USB COM Interface

Set-up

instructions in the

Interface Related Features

chapter of this guide.

NOTE

The host command format is as follows:

P<cnt>pSBC where:

P - ASCII 'P' used as preamble of pass-through commands

<cnt> - binary value of 4 indicating 4 bytes to follow p - ASCII lowercase 'p' ; command to take a picture

S - size value of image as ASCII character

‘S’ == uses scanner's configuration value

‘0’-VGA, (640X480)

‘1’-WVGA, (752X480)

‘2’-SXGA, (1280x1027)

‘3’-CIF (320x240)

B - brightness value in ASCII

‘B’ == uses scanner's configuration value CI_IMAGE_BRIGHTNESS else ‘0’ thru’9’ specifies brightness

C - contrast value in ASCII

‘C’ == uses scanner configuration value CI_IMAGE_CONTRAST else ‘0’ thru’9’ specifies contrast

IF the image is of a type the scanner supports, capture and transmission occurs, and the command is of proper format

THEN

The scanner will transmit an ACK (0x06) to the Host in response to this command.

The image data transmission starts with a 4 byte binary field representing (Big Endian) number of bytes to follow.

If the “number of bytes to follow” value is zero, there was a problem with generating the image and the request should be retried.

ELSE

The scanner will transmit a BEL (0x07) to the Host in response to this command.

ENDIF

32

Magellan TM 3200VSi

Image Compression

Image Compression

Specifies the starting image compression factor for JPEG images. A higher number specifies a higher quality image with less compression than a relative lower number for the same image.

A value of 100 means minimal compression. A value of 1 means maximum compression at a loss of quality. Follow these steps to program this feature:

1. Scan the START bar code.

2. Scan the Set Image Compression bar code.

3. Turn to

Alpha-Numeric Pad

and scan the two digits (zero-padded) representing the desired compression. The configurable range is 01-0x64 by increments of 01.

4. Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Image Compression

DEFAULT SETTING IS

100 (minimal compression — higher quality)

Image Format

Specifies the format of the captured image

START / END

PROGRAMMING bar codes

Image Format = JPG

DEFAULT

Image Format = BMP

Product Reference Guide

33

Image Capture

Image Size

Specifies the size of the image capture. Choices are:

• VGA

• WVGA

• SXGA, Full Size

• CIF

START / END

PROGRAMMING bar codes

Image Size = VGA

DEFAULT

Image Size = WVGA

Image Size = SXGA, Full Size

Image Size = CIF

34

Magellan TM 3200VSi

Image Brightness

Image Brightness

This feature sets the image brightness value. Follow these instructions to configure this feature:

1. Scan the START bar code.

2. Scan the Set Image Brightness bar code.

3. Turn to

Alpha-Numeric Pad

and scan the two digits (zero-padded) representing the desired brightness in decimal notation. The configurable range is 01-0x0A by increments of 01.

4. Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Image Brightness

DEFAULT SETTING FOR THIS FEATURE: 09

Image Contrast

This feature sets the image contrast value. Follow these instructions to configure this feature:

1. Scan the START bar code.

2. Scan the Set Image Contrast bar code.

3. Turn to

Alpha-Numeric Pad

and scan the two digits (zero-padded) representing the desired contrast in decimal notation. The configurable range is 01-0x0A by increments of 01.

4. Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Image Contrast

DEFAULT SETTING FOR THIS FEATURE: 09

Product Reference Guide

35

Image Capture

NOTES

36

Magellan TM 3200VSi

Chapter 6

Interface Related Features

At the time of this writing, the reader supports the interfaces listed in

Table 1

. Select the desired interface type from the table, then reference the page number given for the customizable features section associated with each interface. See

Table 2

for a description of each Keyboard Wedge interface type (A through Y as listed).

Table 1. Interfaces Supported

RS-232

IBM

USB

RS-232 Standard

RS-232 Wincor-Nixdorf

IBM 4683 Port 5B

IBM 4683 Port 9B

IBM 4683 Port 17

USB-OEM

USB Keyboard

Page Keyboard Wedge

39

Keyboard Wedge A a

39

39

39

39

39

39

Keyboard Wedge B a

Keyboard Wedge C

a

Keyboard Wedge D

a

Keyboard Wedge E a

Keyboard Wedge F

a

Keyboard Wedge G

a

Keyboard Wedge H

a

Keyboard Wedge I a

USB COM Interface 39

Keyboard Wedge J

a

a. Consult

Table 2 for more information regarding keyboard interface

types.

40

40

40

40

40

40

40

40

40

40

40

NOTE

The correct interface cable is generally included for the reader interface type you ordered.

37

Product Reference Guide

Interface Related Features

Table 2. Keyboard Wedge Interface Reference

I/F Type PCs Supported

A PC/XT w/Alternate Key Encoding

B

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key

Encoding

C PS/2 25 and 30 w/Alternate Key Encoding

D PC/XT w/Standard Key Encoding

E

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key

Encoding

F PS/2 25 and 30 w/Standard Key Encoding

G IBM 3xxx w/122 keyboard

H IBM 3xxx w/102 keyboard

I PS/55 5530T w/104 keyboard

J NEC 9801

Reference

Appendix E, Keyboard Function Key Mappings for more information about keyboards.

NOTE

38

Magellan TM 3200VSi

Interface Selection

START / END

PROGRAMMING bar codes

RS-232 Standard

RS-232 Wincor-Nixdorf

Interface Selection

IBM 4683 Port 5B

IBM 4683 Port 9B

IBM 4683 Port 17

USB-OEM

USB Keyboard

USB COM Interface

Product Reference Guide

39

Interface Related Features

Interface Selection — cont.

START / END

PROGRAMMING bar codes

Keyboard Wedge A

Keyboard Wedge B

Keyboard Wedge C

Keyboard Wedge D

Keyboard Wedge E

Keyboard Wedge G

³ 0 0 0 1 3 2

Keyboard Wedge I

Keyboard Wedge F

\

Keyboard Wedge H

Keyboard Wedge J

40

Magellan TM 3200VSi

Interface Features

Interface Features

Obey/Ignore Host Commands

When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface, select Obey Host Commands.

START / END

PROGRAMMING bar codes

Obey Host Commands

DEFAULT

Ignore Host Commands

Product Reference Guide

41

Interface Related Features

Interface Features — cont.

Host Transmission Buffers

Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted.

When a DISABLE SCANNER command is received from the host, the scanner will continue to transmit all data that is buffered.

START / END

PROGRAMMING bar codes

Host Transmission Buffers = 1

Host Transmission Buffers = 2

DEFAULT

42

Magellan TM 3200VSi

RS-232 Interface Features

START / END

PROGRAMMING bar codes

Baud Rate

1200 Baud

2400 Baud

4800 Baud

9600 Baud

DEFAULT

³

38400 Baud

19200 Baud

57600 Baud

115200 Baud

Interface Features

Product Reference Guide

43

Interface Related Features

RS-232 Interface Features — cont.

START / END

PROGRAMMING bar codes

Data Bits

8 Data Bits

DEFAULT

Stop Bits

7 Data Bits

1 Stop Bit

DEFAULT

2 Stop Bits

Parity

Parity = None

DEFAULT

Parity = Even

Parity = Odd

44

Magellan TM 3200VSi

Interface Features

RS-232 Interface Features — cont.

Hardware Flow Control

Disable Hardware Control— The scanner transmits to the host regardless of any activity on the

CTS line.

Enable CTS Flow Control— The CTS signal controls transmission of data to the host.

Enable CTS Scan Control— The CTS line must be active for the scanner to read and transmit data.

While the CTS line is inactive, the scanner remains in a host-disabled state; following a successful label transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next label.

START / END

PROGRAMMING bar codes

Disable Hardware Control

DEFAULT

Enable CTS Flow Control

Enable CTS Scan Control

Product Reference Guide

45

Interface Related Features

RS-232 Interface Features — cont.

Intercharacter Delay

This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly.

START / END

PROGRAMMING bar codes

Inter-Char Delay = No Delay

DEFAULT

Interchar Delay = 10 msec

Interchar Delay = 20 msec

Interchar Delay = 30 msec

Interchar Delay = 40 msec

Interchar Delay = 50 msec

Interchar Delay = 60 msec

Interchar Delay = 70 msec

46

Magellan TM 3200VSi

Intercharacter Delay — cont.

START / END

PROGRAMMING bar codes

Interchar Delay = 80 msec

Interchar Delay = 90 msec

Software Flow Control

Disables/Enables software control using XON/XOFF characters.

START / END

PROGRAMMING bar codes

Disable Software Flow Control

DEFAULT

Enable Software Flow Control

Interface Features

Product Reference Guide

47

Interface Related Features

RS-232 Interface Features — cont.

Host Echo

When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary. If, for example, one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmission to the host, the scanner will wait for the RS-232 channel to be quiet for a specified period of time (set via RS-232 Host Echo Quiet Interval ). The scanner can be set to observe this delay before sending its data in order to avoid RS-232 transmission conflicts.

START / END

PROGRAMMING bar codes

Disable Host Echo

DEFAULT

Enable Host Echo

48

Magellan TM 3200VSi

Interface Features

RS-232 Interface Features — cont.

Host Echo Quiet Interval

This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host.

START / END

PROGRAMMING bar codes

Host Echo Quiet Interval = 0msec

Host Echo Quiet Interval = 10msec

DEFAULT

Host Echo Quiet Interval = 20msec

Host Echo Quiet Interval = 30msec

Host Echo Quiet Interval = 40msec

Host Echo Quiet Interval = 50msec

Host Echo Quiet Interval = 60msec

Host Echo Quiet Interval = 70msec

Product Reference Guide

49

Interface Related Features

Host Echo Quiet Interval — cont.

START / END

PROGRAMMING bar codes

Host Echo Quiet Interval = 80msec

Host Echo Quiet Interval = 90msec

Host Echo Quiet Interval = 100msec

Signal Voltage: Normal/TTL

Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS.

START / END

PROGRAMMING bar codes

Signal Voltage: Normal RS-232

DEFAULT

Signal Voltage: TTL

50

Magellan TM 3200VSi

RS-232 Invert

Enables/disables inversion of RS-232 TXD and RXD signals.

START / END

PROGRAMMING bar codes

Disable RS-232 Invert

DEFAULT

Interface Features

Enable RS-232 Invert

Beep on ASCII BEL

Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL

(07 hex).

START / END

PROGRAMMING bar codes

Enable Beep on ASCII BEL

DEFAULT

Disable Beep on ASCII BEL

Product Reference Guide

51

Interface Related Features

Beep on Not on File

Select for the host to beep (or not) when a not-on-file (host command) condition is detected by the host.

START / END

PROGRAMMING bar codes

Disable Beep on Not On File

Enable Beep on Not On File

DEFAULT

52

Magellan TM 3200VSi

Interface Features

ACK NAK Options

This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol.

When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are:

• Disable

• Enable for label transmission — the scanner expects an ACK/NAK response from the host when a label is sent

• Enable for host-command acknowledge — the scanner will respond with ACK/NAK when the host sends a command

• Enable for label transmission and host-command acknowledge

START / END

PROGRAMMING bar codes

Disable ACK NAK

DEFAULT

Enable ACK NAK for Transmission

Enable ACK NAK for host command acknowledge

Enable ACK NAK for transmission and host command

Product Reference Guide

53

Interface Related Features

RS-232 Interface Features — cont.

ACK Character

START / END

PROGRAMMING bar codes

Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK Character,” followed by the digits from the Alphanumeric table in

Appendix C, Alpha-Numeric Pad

representing your desired character. Exit programming mode by again scanning the “START/END” bar code above.

DEFAULT SETTING FOR THIS FEATURE: 006

Set ACK Character

NAK Character

START / END

PROGRAMMING bar codes

Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set NAK Character,” followed by the digits from the Alphanumeric table in

Appendix C, Alpha-Numeric Pad

representing your desired character. Exit programming mode by again scanning the “START/END” bar code above.

DEFAULT SETTING FOR THIS FEATURE: 021

Set NAK Character

54

Magellan TM 3200VSi

Interface Features

RS-232 Interface Features — cont.

Retry on ACK NAK Timeout

Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following feature) has expired.

START / END

Enable Retry on ACK NAK Timeout

DEFAULT

PROGRAMMING bar codes

Disable Retry on ACK NAK Timeout

ACK NAK Timeout Value

START / END

PROGRAMMING bar codes

This item specifies the time the scanner will wait for an ACK character from the host following a label transmission.

000 = Infinite timeout

001 - 075 = Timeout in 200-millisecond increments

To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK NAK

Timeout Value,” followed by the three digits (zero padded) from the Alphanumeric table in

Appendix C, Alpha-Numeric Pad

representing your desired value. Exit programming mode by again scanning the “START/END” bar code above.

DEFAULT SETTING FOR THIS FEATURE: 001 (200 msec)

Set ACK NAK Timeout Value

Product Reference Guide

55

Interface Related Features

RS-232 Interface Features — cont.

ACK NAK Retry Count

START / END

PROGRAMMING bar codes

This feature sets the number of times for the scanner to retry a label transmission under a retry condition.

000 = No retry

001 - 254 = Retry for the specified number of times

255 = Retry forever

To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK NAK

Retry Count,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad

representing your desired retry count. Exit programming mode by again scanning the “START/END” bar code above

DEFAULT SETTING FOR THIS FEATURE: 003

Set ACK NAK Timeout Value

56

Magellan TM 3200VSi

Interface Features

RS-232 Interface Features — cont.

ACK NAK Error Handling

This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. Choices are:

00 = Ignore errors detected (recommended setting)

01 = Process error as valid ACK character (risk of lost label data)

02 = Process error as valid NAK character (risk of duplicate label data)

START / END

PROGRAMMING bar codes

Ignore Errors Detected

DEFAULT

Process error as valid ACK character

Process error as valid NAK character

Product Reference Guide

57

Interface Related Features

RS-232 Interface Features — cont.

Transmission Failure Indication

Enables/disables bad-label indication upon transmission failure.

START / END

PROGRAMMING bar codes

Disable Transmission Error Indication

Enable Transmission Error Indication

DEFAULT

Single Cable RS-232

Single Cable RS-232 Options

The RS-232 Single Cable interface shares some configuration options with other RS-232 interfaces. Rather than repeat them in this section as Single Cable options, please find them referenced as follows:

RS-232 Baud Rate on page 43

RS-232 Number of Data Bits on

page 44

RS-232 Number of Stop Bits on

page 44

RS-232 Parity on page 44

RS-232 Software Flow Control on

page 47

RS-232 Beep on Not on File on

page 52

RS-232 Label ID Control on page 77

58

Magellan TM 3200VSi

Single Cable RS-232

Single Cable RS-232 RTS CTS Selection

Specifies how RTS and CTS are used to control the data flow. RTS is controlled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scanner looks at CTS, as the configuration values state, to determine when to send label data.

Choices are:

• Option 0 = RTS is held in low state and CTS is ignored

• Option 1 = RTS is held in high state and CTS is ignored

• Option 2 = Assert RTS and wait for CTS to be asserted

• Option 3 = Assert RTS and ignore CTS

• Option 4 = RTS held low, wait for CTS to be asserted

• Option 5 = RTS held high, wait for CTS to be asserted

START / END

PROGRAMMING bar codes

RTS CTS Selection =

RTS is held in low state and CTS is ignored

RTS CTS Selection =

RTS is held in high state and CTS is ignored

RTS CTS Selection =

Assert RTS and wait for CTS to be asserted

RTS CTS Selection =

Assert RTS and ignore CTS

RTS CTS Selection =

RTS held low, wait for CTS to be asserted

RTS CTS Selection =

RTS held high, wait for CTS to be asserted

DEFAULT

Product Reference Guide

59

Interface Related Features

Single Cable RS-232 Use BCC

Enables/disables the ability of the scanner to use BCC.

START / END

PROGRAMMING bar codes

Disable BCC

Enable BCC

DEFAULT

Single Cable RS-232 Use ACK/NAK

Enables/disables the ability of the scanner to use ACK/NAK.

START / END

PROGRAMMING bar codes

Disable ACK/NAK

Enable ACK/NAK

DEFAULT

60

Magellan TM 3200VSi

Single Cable RS-232 Use STX

Enables/disables the ability of the scanner to use STX.

START / END

PROGRAMMING bar codes

Disable STX

Enable STX

DEFAULT

Single Cable RS-232

Set Single Cable RS-232 STX Character

This feature selects the STX character.

To specify the STX Character:

1. Scan the START/END bar code.

2. Scan the bar code, SET SINGLE CABLE RS-232 STX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.

3. Scan the appropriate characters/digits from the keypad in Appendix C

that represent the decimal designation for the desired character. A table containing the ASCII Character Set and their corresponding hex values is available in the inside back cover of this manual.

ASCII parameters must be input by scanning decimal digits for each character. Pad all numbers with leading zeroes to yield a three-digit entry (001-127). Thus, to set a single character value of A, bar codes containing the digits ‘0’, ‘6’ and ‘5’ must be scanned. The selectable range for this option is any decimal value from 001 to 127.

4. The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned.

SET SINGLE CABLE RS-232 STX CHARACTER

Product Reference Guide

61

Interface Related Features

Single Cable RS-232 Use ETX

Enables/disables the ability of the scanner to use ETX.

START / END

PROGRAMMING bar codes

Disable ETX

Enable ETX

DEFAULT

Set Single Cable RS-232 ETX Character

Allows selection of the ETX character.

To specify the ETX Character:

1. Scan the START/END bar code.

2. Scan the bar code, SET SINGLE CABLE RS-232 ETX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.

3. Scan the appropriate characters/digits from the keypad in Appendix C

that represent the decimal designation for the desired character. A table containing the ASCII Character Set and their corresponding decimal values is available in the inside back cover of this manual.

ASCII parameters must be input by scanning decimal digits for each character. Pad all numbers with leading zeroes to yield a three-digit entry (001-127). Thus, to set a single character value of A, bar codes containing the digits ‘0’, ‘6’ and ‘5’ must be scanned. The selectable range for this option is any decimal value from 001 to 127.

4. The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned.

SET SINGLE CABLE RS-232 ETX CHARACTER

62

Magellan TM 3200VSi

Single Cable RS-232

Single Cable Pacesetter Plus

Enables/disables sending Pacesetter Plus information as trailers to UPC/EAN labels.

START / END

PROGRAMMING bar codes

Disable Pacesetter Plus

DEFAULT

Enable Pacesetter Plus

Single Cable Datalogic Extensions

Enables Datalogic Scanning, Inc. extensions to the Single Cable RS-232 interface.

START / END

PROGRAMMING bar codes

Disable Datalogic Extensions

DEFAULT

Enable Datalogic Extensions

Product Reference Guide

63

Interface Related Features

USB-OEM Interface Features

USB-OEM Device usage

The USB-OEM protocol allows for the scanner to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a

USB-OEM POS, you may need to change this setting to enable all devices to communicate.

Options are:

• Table Top Scanner

• Handheld Scanner

START / END

PROGRAMMING bar codes

Configure as Table Top Scanner

DEFAULT

Configure as Handheld Scanner

IBM

IBM Transmit Labels in Code 39 Format

This feature enables/disables scanner's ability to set a symbology identifier for a specified label to

Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for USB-OEM; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.

START / END

PROGRAMMING bar codes

Disable Convert to Code 39

DEFAULT

Enable Convert to Code 39

64

Magellan TM 3200VSi

Single Cable RS-232

Keyboard Wedge

USB Keyboard

and

As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn’t require any changes of software or hardware.

All of the options in this section apply to the Key-

board Wedge, however, only some apply to USB Key-

board.

NOTE

Keyboard Layout

The Keyboard Layout option supports many countries. For details about Keyboard Layout, please refer to your operating system manual.

START / END

PROGRAMMING bar codes

USA

DEFAULT

Belgium

Britain

Denmark

France

Germany

Product Reference Guide

65

Interface Related Features

Keyboard Wedge — cont.

START / END

PROGRAMMING bar codes

Norway

Italy

Portugal

Spain

Sweden

Switzerland

Japan 106 Key

Hungary

Czech Republic

66

Magellan TM 3200VSi

Keyboard Wedge — cont.

START / END

PROGRAMMING bar codes

Slovakia

Romania

Croatia

Poland

Caps Lock State

Specifies the format in which the scanner sends character data.

START / END

PROGRAMMING bar codes

Disable Caps Lock

DEFAULT

Caps Lock “ON”

Single Cable RS-232

Shift Lock “ON”

Product Reference Guide

67

Interface Related Features

Keyboard Wedge — cont.

Power-On Simulation

This feature does not apply to the USB Keyboard interface.

NOTE

All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on.

START / END

PROGRAMMING bar codes

Disable Power-on Simulation

DEFAULT

Enable Power-on Simulation

68

Magellan TM 3200VSi

Single Cable RS-232

Control Characters

Specifies how the scanner transmits ASCII control characters to the host. Choices are:

• Disable Control Characters

• Enable transmission of control characters to host

• Send characters between 00H and 1FH according to a special function-key mapping table. (This is used to send keys that are not in the normal ASCII set; a unique set is pro-

vided for each available scancode set. Reference Appendix E, Keyboard Function Key Mappings .)

START / END

PROGRAMMING bar codes

Disable Control Characters

DEFAULT

Enable Transmission of Control Characters

Enable Function Key Mapping

Product Reference Guide

69

Interface Related Features

Keyboard Wedge — cont.

Wedge Quiet Interval

This feature does not apply to the USB Keyboard interface.

NOTE

Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host.

START / END

PROGRAMMING bar codes

Selectable from 001 to 100 in 10 msec increments. To configure this feature, scan the “START/END” bar code above to place the unit

in Programming Mode, then the Set Wedge Quiet Interval bar code followed by the three digits (zero padded) from the Alphanu-

meric table in

Appendix C, Alpha-Numeric Pad

representing your desired length. Exit programming mode by again scanning the

“START/END” bar code above.

DEFAULT SETTING FOR THIS FEATURE:

010 (100 msec)

Set Wedge Quiet Interval

70

Magellan TM 3200VSi

USB COM Interface Set-up

Keyboard Wedge — cont.

Intercharacter Delay

START / END

PROGRAMMING bar codes

One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Selectable from 00 to 99 in 10msec increments.

To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Intercharacter Delay,” followed by the three digits (zero padded) from the Alphanumeric table in

Appendix C, Alpha-Numeric Pad

representing your desired length. Exit programming mode by again scanning the “START/END” bar code above/

DEFAULT SETTING FOR THIS FEATURE:

00 (No Delay)

Set Intercharacter Delay

USB COM Interface Set-up

The scanner has two USB COM interfaces, USB COM and USB COM DL (Datalogic). The

Datalogic USB-COM driver works for both USB COM interfaces.

Before plugging your scanner into the Host PC, please ensure you have already copied the executable DLS-USB-COM driver file to your PC and that the scanner’s interface is set to USB

COM or USB COM DL. The DLS-USB-COM driver is provided by Datalogic or downloaded from the Datalogic Scanning website listed on the back cover of this manual.

1. Execute the DLS-USB-COM driver file.

2. When the scanner is first plugged into the PC, Windows will bring up the “Found New

Hardware” message.

3. The installation is complete.

Product Reference Guide

71

Interface Related Features

NOTES

72

Magellan TM 3200VSi

Chapter 7

Data Editing

Data Editing Overview

It is not recommended to use these features with IBM interfaces.

CAUTION

When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string.

There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbolo-

gies.

Figure 1

shows the available elements you can add to a message string:

Figure 1. Breakdown of a Message String

L ab el ID Tr a n s mi ss ion:

En ab le thi s option to tr a n s mit the L ab el ID yo u config u re for the s c a nned s ym b ology.

OR...

Prefix L ab el ID AIM ID B a r Code D a t a L ab el ID Su ffix

AIM ID: Thi s f u nction i s us ed to identify a nd di s pl a y the common l ab el identifier for it s s ym b ology. When en ab led, thi s ID code will b e tr a n s mitted b efore the s c a nned ba r code d a t a .

00 - 20 Ch a r a cter s (A S CII)

Please Keep In Mind...

• Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.

A prefix or suffix may be applied (reference the

Symbologies

chapter for these settings)

across all symbologies (set via the Global features in this chapter).

• You can add any character from the

ASCII Chart

(from 00-FF) on the inside back cover of this manual as a prefix, suffix or Label ID.

• Enter prefixes and suffixes in the order in which you want them to appear on the output.

Product Reference Guide

73

Data Editing

Global Prefix/Suffix

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/

or as a suffix (in a position following the bar code data) as indicated in Figure 2 .

Figure 2. Prefix and Suffix Positions

OR...

Prefix L ab el ID AIM ID B a r Code D a t a

00 - 20 Ch a r a cter s (A S CII)

AND

OR

L ab el ID Su ffix

Example: Setting a Prefix

In this example, we’ll set a prefix for all symbologies.

1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix.

2. Scan the START bar code.

3. Scan the SET PREFIX bar code.

4. Reference the ASCII Chart on the inside back cover of this manual, to find the hex value

assigned to the desired character. The corresponding hex number for the ‘$’ character is

24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from

Appendix C, Alpha-

Numeric Pad .

5. Scan the END bar code once to finish the string, then scan END again to exit Programming Mode.

If all 20 characters will be used in the prefix or suffix, do not scan the END bar code to finish the string. It is done automatically.

NOTE

6. The resulting message string would appear as follows:

Scanned bar code data:12345

Resulting message string output: $12345

74

Magellan TM 3200VSi

Global Prefix/Suffix

Global Prefix/Suffix — cont.

START / END

PROGRAMMING bar codes

Sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. To configure this feature, scan the

“START/END” bar code above to place the unit in Programming Mode, then the “Set Prefix” or “Set Suffix,” followed by the digits from the Alphanumeric table in

Appendix C, Alpha-Numeric Pad

representing your desired character(s). Reference the section,

"Example: Setting a Prefix" , for more information. Exit programming mode by scanning the “START/END” bar code again (scan

“START/END” twice if less than 20 characters have been selected).

DEFAULT SETTING PREFIX: 00 (None)

DEFAULT SETTING SUFFIX: 0D (CR)

Set Prefix

Set Suffix

Product Reference Guide

75

Data Editing

AIM ID

AIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list — as opposed to custom label ID characters you select yourself — and can be included with scanned bar code data. AIM label identifiers consist of three characters as follows:

• A close brace character (ASCII ‘]’), followed by...

• A code character (see the table below), followed by...

• A modifier character (the modifier character is symbol dependent)

SYMBOLOGY CHAR SYMBOLOGY

UPC/EAN

Code 39

E

A

Codabar

Interleaved 2 of 5

F

I

Code 93 G a. ISBN (X with a 0 modifier character)

Code 128/EAN 128

GS1 Omnidirectional, GS1

Expanded

Standard 2 of 5

ISBN

CHAR

C e

S

X a

Figure 3. AIM ID

Prefix L ab el ID AIM ID B a r Code D a t a L ab el ID Su ffix

76

START / END

PROGRAMMING bar codes

Disable AIM ID

DEFAULT

Enable AIM ID

Magellan TM 3200VSi

Label ID

Label ID

A Label ID is used to identify a bar code (symbology) type. See Appendix D, Factory Default Settings , for a listing for common symbologies. It can be appended previous to or following the

transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology. If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types, see the previous feature,

AIM ID .

The Label ID is a customizable code of up to three ASCII characters (each of which are 00-FF) followed by a control character (00-01), This control character, when set to zero, does nothing.

When set to one, it appends the symbology’s AIM ID to the Label ID.

When the control character is set to 01 for UPC-A and

UPC-E, it expands the label to EAN-13 and thus follows the EAN-13 Label ID settings.

NOTE

To configure a Label ID:

1. Scan the START bar code.

2. Select Label ID position as either BEFORE or AFTER by scanning the appropriate bar code.

3. Scan a bar code to select the symbology for which you wish to configure a custom Label

ID.

4. Determine the desired character(s) (you may choose up to three) which will represent the

Label ID for the selected symbology. Next, turn to the ASCII Chart on the inside back

cover of this manual and find the equivalent hex digits associated with your choice of

Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D.

5. Turn to Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex charac-

ters determined in the previous step. For example, to make an equal sign (=), scan ‘3’ and

‘D’ followed by ‘0’ six times. Since this is a three-character buffer, ‘00’ is scanned for character two, ‘00’ for character three and ‘00’ for the control character. (‘00’ indicates no character.)

6. Scan the END bar code to exit programming mode.

Figure 4. Label ID Position Options

OR

Prefix L ab el ID Aim ID B a r Code D a t a L ab el ID Su ffix

Product Reference Guide

77

Data Editing

Label ID — cont.

START / END

PROGRAMMING bar codes

Label ID Transmission: Disable

Label ID Position: Before Bar Code Data

DEFAULT

Label ID Position

Label ID Position: After Bar Code Data

Set UPC-A Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: A (41 hex)

Set UPC-A w/P2 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: A (41 hex)

Set UPC-A w/P5 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: A (41 hex)

Set UPC-E Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: A (41 hex)

Set UPC-A w/C128 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: E (45 hex)

78

Magellan TM 3200VSi

Label ID — cont.

START / END

PROGRAMMING bar codes

Set UPC-E w/P2 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: E (45 hex)

Set UPC-E w/P5 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: E (45 hex)

Label ID

Set UPC-E w/C128 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: E (45 hex)

Set EAN-8 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)

Set EAN-8 w/P2 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)

Set EAN-8 w/P5 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)

Set EAN-8 w/C128 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)

Set EAN-13 Label ID Character(s)

Product Reference Guide

79

Data Editing

Label ID — cont.

START / END

PROGRAMMING bar codes

Set EAN-13 w/P2 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: F (46 hex)

Set EAN-13 w/P5 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: F (46 hex)

Set EAN-13 w/C128 Addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: F (46 hex)

Set ISBN Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: I (49 hex)

Set IATA Label ID Character(s)

Set GTIN Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: G (47 hex)

Set GTIN w/P2 addon Label ID Character(s)

Set GTIN w/P5 addon Label ID Character(s)

80

Magellan TM 3200VSi

Label ID

Label ID — cont.

START / END

PROGRAMMING bar codes

Set GTIN w/C128 addon Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: G8 (4738 hex)

Set GS1 Omnidirectional Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: R4 (5234 hex)

Set GS1 Expanded Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: RX (5258 hex)

Set Code GS1 DataBar Limited Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: * (524C0000 hex)

Set Code 39 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: * (2A hex)

Set Pharmacode 39 Label ID Character(s)

Set Code 128 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: # (23 hex)

Set I 2 of 5 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: i (69 hex)

Product Reference Guide

81

Data Editing

Label ID — cont.

START / END

PROGRAMMING bar codes

Set Codabar Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: % (25 hex)

Set Code 93 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: & (26 hex)

Set Code 11 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)

Set EAN UCC Composite Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: 0

Set PDF 417 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: P (5000 hex) a

Set Datamatrix Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: Dm (446D hex) a.

Default setting exceptions for PDF 417 Label ID are as follows: Default for RS-232 WN is ‘Q’ (0x5100). Default for USB-HID-

POS is ‘P ‘ (0x5020), or ‘P-Space’.

82

Magellan TM 3200VSi

Label ID

Label ID — cont.

NOTE

For the 2D symbologies on this page, the Label ID is 4 bytes. The first 3 bytes are characters for the label ID. A

00 (hex) value in the first 3 bytes indicates the end of the label ID characters. The 4th byte is a control byte.

The use of the control byte is as follows: bit 0-if set to 1, the AIM ID is appended for that label type

START / END

PROGRAMMING bar codes

Set Micro PDF 417 Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: mP (6D500000 hex)

Set QR Code Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: QR (51520000 hex)

Set Maxicode Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: MC (4D430000 hex)

Set Aztec Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: R4 (52340000 hex)

DEFAULT SETTING FOR THIS FEATURE: Az (417A0000 hex)

Set GS1 DataBar Omnidirectional 2D Composite

Label ID Character(s)

Set GS1 DataBar Limited 2D Composite

Label ID Character(s)

DEFAULT SETTING FOR THIS FEATURE: RX (52340000 hex)

DEFAULT SETTING FOR THIS FEATURE: RL (524C0000 hex)

Set GS1 DataBar Expanded 2D Composite

Label ID Character(s)

Product Reference Guide

83

Data Editing

Case Conversion

This feature can convert scanned bar code data to either all lower case (a through z) or all upper case (A through Z) characters.

Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data.

NOTE

START / END

PROGRAMMING bar codes

Disable

DEFAULT

Convert to Upper Case

Convert to Lower Case

84

Magellan TM 3200VSi

Character Conversion

Character Conversion

Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF , then no conversion is done.

For example, if you have the character conversion configuration item set to the following:

41423132FFFFFFFF

The first pair is 4142 or AB ( 41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 ( 31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF .

With the label, AG15TA81, it would look as follows after the character conversion:

BG25TB82.

The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character. Nothing is done with the last two character pairs, since they are all FF .

To set Character Conversion:

1. Scan the START/END bar code.

2. Scan the Character Conversion bar code.

3. Determine the desired string. Up to sixteen positions can be determined as in the above

example. Next, turn to the ASCII Chart on the inside back cover of this manual and find

the equivalent hex digits needed to fulfill the string.

The positions not used must be filled with the character ‘F’.

NOTE

4. Turn to Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex charac-

ters determined in the previous step. When the last character is scanned, the scanner will sound a triple beep.

5. Scan the START/END bar code to exit Programming Mode.

START / END

PROGRAMMING bar codes

Character Conversion

DEFAULT SETTING FOR THIS FEATURE:

FFFFFFFFFFFFFFFF hex (no conversion)

Product Reference Guide

85

Data Editing

NOTES

86

Magellan TM 3200VSi

Chapter 8

Symbologies

The scanner supports the following symbologies (bar code types). Options for each symbology are included in this chapter.

UPC-A

UPC-E

EAN-13

EAN-8

GS1 DataBar Omnidirectional /

Stacked Omnidirectional

GS1 DataBar Expanded /

Expanded Stacked

GS1 DataBar Limited

Code 39

Code 32 Italian

Pharmacode

Code 128

Interleaved 2 of 5

Codabar

Code 93

Factory Defaults— for the standard RS-232 interface are indicated in bold text throughout this

section. Reference Appendix D, Factory Default Settings for default exceptions for your interface.

UPC-A

Disable/Enable UPC-A

When disabled, the scanner will not read UPC-A bar codes.

START / END

PROGRAMMING bar codes

Disable UPC-A

Enable UPC-A

DEFAULT

87

Product Reference Guide

Symbologies

UPC-A — cont.

Check Digit Transmission

Enable this option to transmit the check digit along with UPC-A bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

³

Send Check Digit

DEFAULT

Number System Transmission

This feature enables/disables transmission of UPC-A System Number.

START / END

PROGRAMMING bar codes

Disable Number System Transmission

Enable Number System Transmission

DEFAULT

88

Magellan TM 3200VSi

UPC-A

UPC-A — cont.

Expand UPC-A to EAN-13

Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

START / END

PROGRAMMING bar codes

Don’t Expand to EAN-13

DEFAULT

Expand to EAN-13

Product Reference Guide

89

Symbologies

UPC-E

The following options apply to the UPC-E symbology.

Disable/Enable UPC-E

When disabled, the scanner will not read UPC-E bar codes.

START / END

PROGRAMMING bar codes

Disable UPC-E

Enable UPC-E

DEFAULT

Check Digit Transmission

Enable this option to transmit the check digit along with UPC-E bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

Send Check Digit

DEFAULT

90

Magellan TM 3200VSi

UPC-E — cont.

Number System Digit

The Number System Digit (NSD) which is always a zero (0) in the leading position can be optionally included (or not) with scanned bar code data.

UPC-E

START / END

PROGRAMMING bar codes

Exclude Number System Digit

DEFAULT

Include Number System Digit

³ 0 2 8 0 1

Expand to UPC-E to UPC-A

Enables/disables expansion of UPC-E labels to UPC-A.

Selecting this feature also changes the symbology ID to match those required for UPC-A.

START / END

PROGRAMMING bar codes

Don’t Expand UPC-E to UPC-A

DEFAULT

Expand UPC-E to UPC-A

Product Reference Guide

91

Symbologies

UPC-E — cont.

Expand UPC-E to EAN13

Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also changes the symbology ID to match those required for EAN-13.

START / END

PROGRAMMING bar codes

Don’t Expand UPC-E to EAN-13

DEFAULT

Expand UPC-E to EAN-13

92

Magellan TM 3200VSi

UPC-E

GTIN

The following options apply to the GTIN label data format.

Expand UPC/EAN to GTIN

When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format.

START / END

PROGRAMMING bar codes

Don’t Expand to GTIN

DEFAULT

Expand to GTIN

Product Reference Guide

93

Symbologies

EAN-13

The following options apply to the EAN-13 symbology.

Disable/Enable EAN-13

When disabled, the scanner will not read EAN-13 bar codes.

START / END

PROGRAMMING bar codes

Disable EAN-13

Enable EAN-13

DEFAULT

Check Digit Transmission

Enable this option to transmit the check digit along with EAN-13 bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

Send Check Digit

DEFAULT

94

Magellan TM 3200VSi

EAN-13

EAN-13 — cont.

EAN-13 Flag 1 Character

Enables/disables transmission of an EAN/JAN13 Flag1 character.

START / END

PROGRAMMING bar codes

Don’t Transmit EAN-13 Flag 1 Char

Transmit EAN-13 Flag 1 Char

DEFAULT

ISBN

When enabled, this feature truncates the leading three digits from labels that contain ISBN

(International Standard Book Number) and appends an ISBN check character to the end of the label. These codes are used for books and magazines. Labels with ISBN codes start with "978".

Example:

Bar Code data:

Output:

“9789572222720”

“9572222724”

START / END

PROGRAMMING bar codes

Disable ISBN

DEFAULT

Enable ISBN

Product Reference Guide

95

Symbologies

EAN-8

The following options apply to the EAN-8 symbology.

Disable/Enable EAN-8

When disabled, the scanner will not read EAN-8 bar codes.

START / END

PROGRAMMING bar codes

Disable EAN-8

Enable EAN-8

DEFAULT

Check Digit Transmission

Enable this option to transmit the check Digit along with EAN-8 bar code data.

START / END

PROGRAMMING bar codes

Don’t Send Check Digit

Send Check Digit

DEFAULT

96

Magellan TM 3200VSi

EAN-8

EAN-8 — continued

Expand EAN-8 to EAN-13— Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

START / END

PROGRAMMING bar codes

Don’t Expand to EAN-13

DEFAULT

Expand to EAN-13

Product Reference Guide

97

Symbologies

EAN Two-Label

Enables/disables the ability of the scanner to decode EAN two-label pairs.

START / END

PROGRAMMING bar codes

Disable EAN Two-Label

Enable EAN Two-Label

EAN Two-Label Combined Transmission

Enables/disables the transmitting of an EAN two label pair as one label.

START / END

PROGRAMMING bar codes

EAN Two-Label Combined Transmission = Disable

DEFAULT

EAN Two-Label Combined Transmission = Enable

98

Magellan TM 3200VSi

Price Weight Check Digit

Price Weight Check Digit

Enables/disables calculation and verification of price/weight check digits.

Applies to all UPC-A labels with a number-system character of 2 and

EAN/JAN 13 labels with a

1 digit of 2

NOTE

Here are the available options for this feature:

• Disable

• Enable 4-digit price/wt check-digit calculation

• Enable 5-digit price/wt check-digit calculation

• Enable European 4-digit price-weight check-digit calculation

• Enable European 5-digit price-weight check-digit calculation

START / END

PROGRAMMING bar codes

Price Weight Check Digit = Disable

DEFAULT

Price Weight Check Digit = Enable 4-digit price/wt

Price Weight Check Digit = Enable 5-digit price/wt

Price Weight Check Digit = Enable European 4-digit price/wt

Price Weight Check Digit = Enable European 5-digit price/wt

Product Reference Guide

99

Symbologies

Add-ons

Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes.

The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported options are:

None— This option directs the scanner to ignore add-on portion of a UPC/EAN bar code but still read the main portion of the bar code.

2 Digits— The scanner will optionally read 2-digit add-ons with the UPC/EAN label.

5 Digits— The scanner will optionally read 5-digit add-ons with the UPC/EAN label.

Code 128 Add-on— The scanner will optionally read Code 128 add-ons with the UPC/EAN label.

Contact Customer Support for advanced programming of optional and conditional add-ons.

NOTE

100

Magellan TM 3200VSi

Add-ons — continued

START / END

Enable Optional 2-Digit Add-ons

PROGRAMMING bar codes

Disable Optional 2-Digit Add-ons

DEFAULT

Disable Optional 5-Digit Add-ons

DEFAULT

Enable Optional 5-Digit Add-ons

³

Disable Optional Code 128 Add-ons

DEFAULT

Add-ons

Enable Optional Code 128 Add-ons

Product Reference Guide

101

Symbologies

GS1 DataBar Omnidirectional / Stacked Omnidirectional

The following options apply to the GS1 DataBar Omnidirectional symbology.

Disable/Enable GS1 DataBar Omnidirectional

When this feature is disabled, the scanner will not read GS1 DataBar Omnidirectional bar codes.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Omnidirectional

DEFAULT

Enable GS1 DataBar Omnidirectional

UCC/EAN 128 Emulation

When enabled, GS1 DataBar Omnidirectional bar codes will be translated to the UCC/EAN

128 label data format.

START / END

PROGRAMMING bar codes

Disable UCC/EAN 128 Emulation

DEFAULT

Enable UCC/EAN 128 Emulation

102

Magellan TM 3200VSi

GS1 DataBar Expanded / Expanded Stacked

GS1 DataBar Expanded / Expanded Stacked

The following options apply to the GS1 DataBar Expanded symbology.

Disable/Enable GS1 DataBar Expanded

When this feature is disabled, the scanner will not read GS1 DataBar Expanded bar codes.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Expanded

DEFAULT

Enable GS1 DataBar Expanded

GS1-128 Emulation

When enabled, GS1 DataBar Expanded bar codes will be translated to the GS1-128 label data format.

START / END

PROGRAMMING bar codes

Disable GS1-128 Emulation

DEFAULT

Enable GS1-128 Emulation

Product Reference Guide

103

Symbologies

GS1 DataBar Expanded / Expanded Stacked — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START/END bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the START/END bar code.

4. Set Length 1 to the first fixed length by following the

GS1 DataBar Expanded Length 1,

Length 2 Programming Instructions

below.

5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the

GS1 DataBar Expanded Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START/END bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the START/END bar code.

4. Set Length 1 to the first variable length by following the GS1 DataBar Expanded Length 1,

Length 2 Programming Instructions

below.

5. Set Length 2 to the second variable length by following the GS1 DataBar Expanded Length

1, Length 2 Programming Instructions

below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

104

Magellan TM 3200VSi

GS1 DataBar Expanded / Expanded Stacked

GS1 DataBar Expanded / Expanded Stacked — continued

GS1 DataBar Expanded Length 1, Length 2 Programming Instructions

1. Scan the START/END bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the two digits (zero padded) representing the length in decimal notation.

For GS1 DataBar Expanded bar codes, only the data characters are included in the length calculations.

NOTE

4. Scan the START/END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 01

Set Length 2

Product Reference Guide

105

Symbologies

GS1 DataBar Expanded / Expanded Stacked — continued

Coupon Read Control

This feature controls coupon reading.

START / END

PROGRAMMING bar codes

Disable coupon filtering

Enable UPCA coupon decoding

Disable GS1 DataBar coupon decoding

DEFAULT

Enable GS1 DataBar coupon decoding

Disable UPCA coupon decoding

106

Magellan TM 3200VSi

GS1 DataBar Limited

GS1 DataBar Limited

The following options apply to the GS1 DataBar Limited symbology.

Disable/Enable GS1 DataBar Limited

When this feature is disabled, the scanner will not read GS1 DataBar Limited bar codes.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Limited

DEFAULT

Enable GS1 DataBar Limited

GS1-128 Emulation

When enabled, GS1 DataBar Limited bar codes will be translated to the GS1-128 label data format.

START / END

PROGRAMMING bar codes

Disable GS1-128 Emulation

DEFAULT

Enable GS1-128 Emulation

Product Reference Guide

107

Symbologies

Code 39

The following options apply to the Code 39 symbology.

Disable/Enable Code 39

When this feature is disabled, the scanner will not read Code 39 bar codes.

START / END

PROGRAMMING bar codes

Disable Code 39

Enable Code 39

DEFAULT

Check Character Calculation

When enabled, the scanner will calculate the check character of the labels. Turn this option on only when a checksum is present in the Code 39 labels.

START / END

PROGRAMMING bar codes

Disable Check Char Calculation

DEFAULT

Enable Check Char Calculation

108

Magellan TM 3200VSi

Check Character Transmit

Enable this option to transmit the check character with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Char Transmission

Enable Check Char Transmission

DEFAULT

Start/Stop Characters

Enables/disables transmission of Code39 start and stop characters.

START / END

PROGRAMMING bar codes

Don’t Transmit Start/Stop Characters

DEFAULT

Code 39

Transmit Start/Stop Characters

Product Reference Guide

109

Symbologies

Code 39 Full ASCII

Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters

.

START / END

PROGRAMMING bar codes

Disable Code 39 Full ASCII

DEFAULT

Enable Code 39 Full ASCII

110

Magellan TM 3200VSi

Code 39

Code 39 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START/END bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the START/END bar code.

4. Set Length 1 to the first fixed length by following the

Code 39 Length 1, Length 2 Programming Instructions

below.

5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the

Code 39 Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START/END bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the START/END bar code.

4. Set Length 1 to the first variable length by following the

Code 39 Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the second variable length by following the

Code 39 Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide

111

Symbologies

Code 39 Length 1, Length 2 Programming Instructions

1. Scan the START/END bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the two digits (zero padded) representing the length in decimal notation.

For Code 39 bar codes, all check, data and full ASCII shift characters are included in the length calculations.

Start/Stop characters are not included.

NOTE

4. Scan the START/END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 02

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

112

Magellan TM 3200VSi

Code 32 Italian Pharmacode

Code 32 Italian Pharmacode

The following options apply to the Code 32 Italian Pharmacode symbology.

Disable/Enable Code 32 Italian Pharmacode

When this feature is disabled, the scanner will not read Code 32 Italian Pharmacode bar codes.

START / END

PROGRAMMING bar codes

Disable Code 32 Italian Pharmacode

DEFAULT

Enable Code 32 Italian Pharmacode

Start/Stop Characters

Enables or disables transmission of Code 32 Italian Pharmacode start/stop characters.

START / END

PROGRAMMING bar codes

Don’t Transmit Start/Stop Characters

DEFAULT

Transmit Start/Stop Characters

³ 0 0 6 0 1

Product Reference Guide

113

Symbologies

Code 32 Italian Pharmacode — continued

Check Character Transmit

Enable this option to transmit the check character with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Char Transmission

Enable Check Char Transmission

DEFAULT

114

Magellan TM 3200VSi

Code 128

The following options apply to the Code 128 symbology.

Disable/Enable Code 128

When this feature is disabled, the scanner will not read Code 128 bar codes.

START / END

PROGRAMMING bar codes

Disable Code 128

Enable Code 128

DEFAULT

Code 128

Disable/Enable EAN 128

When this feature is disabled, the scanner will not read EAN 128 bar codes.

START / END

PROGRAMMING bar codes

Disable EAN 128

Enable EAN 128

DEFAULT

Product Reference Guide

115

Symbologies

Code 128 — continued

Transmit Function Characters

Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4.

Function codes are transmitted as follows:

• FNC1 = 80 hex

• FNC2 = 81 hex

• FNC3 = 82 hex

• FNC4 = 83 hex

START / END

PROGRAMMING bar codes

Don’t Transmit Function Characters

DEFAULT

Transmit Function Characters

116

Magellan TM 3200VSi

Code 128

Code 128 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the

Code 128 Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the

Code 128 Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first variable length by following the

Code 128 Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the second variable length by following the Code 128 Length 1, Length 2

Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide

117

Symbologies

Code 128 — continued

Code 128 Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the two digits (zero padded) representing the length in decimal notation.

For Code 128 bar codes, only the data characters are included in the length calculations.

NOTE

4. Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 01

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 80

Code 128 Conversion to Code 39

Enables/disables expansion of Code 128 labels to Code 39.

START / END

PROGRAMMING bar codes

Disable

DEFAULT

Enable

118

Magellan TM 3200VSi

Interleaved 2 of 5

Interleaved 2 of 5

The following options apply to the Interleaved 2 of 5 (I 2 of 5) symbology.

Disable/Enable Interleaved 2 of 5

When this feature is disabled, the scanner will not read Interleaved 2 of 5 bar codes.

START / END

PROGRAMMING bar codes

Disable Interleaved 2 of 5

DEFAULT

Enable Interleaved 2 of 5

Check Digit Calculation

When enabled, the scanner will calculate the check digit of the labels.

START / END

PROGRAMMING bar codes

Disable Check Digit Calculation

DEFAULT

Enable Check Digit Calculation

Product Reference Guide

119

Symbologies

Interleaved 2 of 5 — continued

Check Digit Transmit

Enable this option to transmit the check digit with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Digit Calculation

DEFAULT

Enable Check Digit Calculation

120

Magellan TM 3200VSi

Interleaved 2 of 5

Interleaved 2 of 5 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the

Interleaved 2 of 5 Length 1, Length 2

Programming Instructions below.

5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the

Interleaved 2 of 5 Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first variable length by following the

Interleaved 2 of 5 Length 1, Length

2 Programming Instructions

below.

5. Set Length 2 to the second variable length by following the Interleaved 2 of 5 Length 1,

Length 2 Programming Instructions

below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide

121

Symbologies

Interleaved 2 of 5 — continued

Interleaved 2 of 5 Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the two digits (zero padded) representing the length in decimal notation

.

For Interleaved 2 of 5 bar codes, lengths must be an even number. Additionally, all check and data characters are included in the length calculations.

NOTE

4. Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 06

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

122

Magellan TM 3200VSi

Codabar

The following options apply to the Codabar symbology.

Disable/Enable Codabar

When this feature is disabled, the scanner will not read Codabar bar codes.

START / END

PROGRAMMING bar codes

Disable Codabar

DEFAULT

Enable Codabar

Check Character Verification

When enabled, the scanner will verify the check character of the labels.

START / END

PROGRAMMING bar codes

Disable Check Char Verification

DEFAULT

Enable Check Char Verification

Codabar

Product Reference Guide

123

Symbologies

Check Character Transmit

Enable this option to transmit the check character with scanned bar code data.

START / END

PROGRAMMING bar codes

Disable Check Char Transmission

Enable Check Char Transmission

DEFAULT

124

Magellan TM 3200VSi

Codabar

Codabar — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the

Codabar Length 1, Length 2 Programming Instructions

below.

5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the

Codabar Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first variable length by following the Codabar Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the second variable length by following the Codabar Length 1, Length 2

Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide

125

Symbologies

Codabar — continued

Codabar Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the two digits (zero padded) representing the length in decimal notation.

For Codabar bar codes, all start, stop, check and data characters are included in the length calculations.

NOTE

4. Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 03

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

126

Magellan TM 3200VSi

Codabar — continued

Start/Stop Character Type

Codabar has four pairs of Start/Stop patterns. Select one pair to match your application.

Codabar

START / END

PROGRAMMING bar codes

Start/Stop Type: ABCD/TN*E

Start/Stop Type: ABCD/ABCD

Start/Stop Type: abcd/tn*e

Start/Stop Type: abcd/abcd

DEFAULT

Start/Stop Character Transmission

The transmission of start and end characters of Codabar is selected below.

START / END

PROGRAMMING bar codes

Disable Start/Stop Char Transmission

Enable Start/Stop Char Transmission

DEFAULT

Product Reference Guide

127

Symbologies

Start/Stop Character Match

This feature enables/disables the requirement that start and stop characters match

.

START / END

PROGRAMMING bar codes

Disable Start/Stop Char Match

DEFAULT

Enable Start/Stop Char Match

128

Magellan TM 3200VSi

Code 93

The following options apply to the Code 93 symbology.

Disable/Enable Code 93

When this feature is disabled, the scanner will not read Code 93 bar codes.

START / END

PROGRAMMING bar codes

Disable Code 93

DEFAULT

Enable Code 93

Code 93

Product Reference Guide

129

Symbologies

Code 93 — continued

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START/END bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the START/END bar code.

4. Set Length 1 to the first fixed length by following the

Code 93 Length 1, Length 2 Programming Instructions

below.

5. Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by following the

Code 93 Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START/END bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the START/END bar code.

4. Set Length 1 to the first variable length by following the

Code 93 Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the second variable length by following the

Code 93 Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

130

Magellan TM 3200VSi

Code 93

Code 93 — continued

Code 93 Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to Appendix C, Alpha-Numeric Pad

and scan the two digits (zero padded) representing the length in decimal notation.

For Code 93 bar codes, only the data characters are included in the length calculations.

NOTE

4. Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 01

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 50

Product Reference Guide

131

Symbologies

NOTES

132

Magellan TM 3200VSi

2D Symbologies

The features in this section are available ONLY for models with 2D features activated.

NOTE

2D Symbologies

The scanner supports the 2D symbologies (bar code types) listed below. Available options for each 2D symbology are included in this chapter.

PDF 417

Micro PDF 417

Datamatrix

QR Code

Maxicode

Aztec

Composite Labels

Factory Defaults— for the standard RS-232 interface are indicated in bold text throughout.

Product Reference Guide

133

2D Symbologies

PDF 417

Disable/Enable PDF 417

When disabled, the scanner will not read PDF 417 bar codes.

START / END

PROGRAMMING bar codes

Disable PDF 417

Enable PDF 417

DEFAULT

134

Magellan TM 3200VSi

2D Symbologies

PDF 417 — cont.

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

PDF 417 Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the PDF 417 Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the PDF 417 Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide

135

2D Symbologies

PDF 417 — cont.

PDF 417 Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to

Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing

the length.

For PDF 417 bar codes, only the data characters are included in the length calculations.

Any value set higher than 2710 will be considered to be 2710.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 2710

136

Magellan TM 3200VSi

Micro PDF 417

Disable/Enable Micro PDF 417

When disabled, the scanner will not read Micro PDF 417 bar codes.

START / END

PROGRAMMING bar codes

Disable Micro PDF 417

DEFAULT

2D Symbologies

Enable Micro PDF 417

Product Reference Guide

137

2D Symbologies

Micro PDF 417 — cont.

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Micro PDF 417 Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Micro PDF 417 Length 1, Length 2

Programming Instructions below.

5. Set Length 2 to the maximum length by following the Micro PDF 417 Length 1, Length 2

Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

138

Magellan TM 3200VSi

2D Symbologies

Micro PDF 417 — cont.

Micro PDF 417 Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to

Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing

the length.

For Micro PDF 417 bar codes, only the data characters are included in the length calculations.

Any value set higher than 366 will be considered to be 366.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 0366

Product Reference Guide

139

2D Symbologies

Datamatrix

Disable/Enable Datamatrix

When disabled, the scanner will not read Datamatrix bar codes.

START / END

PROGRAMMING bar codes

Disable Datamatrix

Enable Datamatrix

DEFAULT

140

Magellan TM 3200VSi

2D Symbologies

Datamatrix — cont.

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Datamatrix Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Datamatrix Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the Datamatrix Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide

141

2D Symbologies

Datamatrix — cont.

Datamatrix Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to

Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing

the length.

For Datamatrix bar codes, only the data characters are included in the length calculations.

Any value set higher than 800 will be considered to be 800.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 0800

142

Magellan TM 3200VSi

QR Code

Disable/Enable QR Code

When disabled, the scanner will not read QR Code labels.

START / END

PROGRAMMING bar codes

Disable QR Code

DEFAULT

Enable QR Code

2D Symbologies

Product Reference Guide

143

2D Symbologies

QR Code — cont.

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

QR Code Length 1, Length 2 Programming Instructions

below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the QR Code Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the QR Code Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

144

Magellan TM 3200VSi

2D Symbologies

QR Code — cont.

QR Code Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to

Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing

the length.

For 2d Code labels, only the data characters are included in the length calculations.

Any value set higher than 2710 will be considered to be 2710.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 2710

Product Reference Guide

145

2D Symbologies

Maxicode

Disable/Enable Maxicode

When disabled, the scanner will not read Maxicode labels.

START / END

PROGRAMMING bar codes

Disable Maxicode

DEFAULT

Enable Maxicode

146

Magellan TM 3200VSi

2D Symbologies

Maxicode — cont.

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Maxicode Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Maxicode Length 1, Length 2 Programming Instructions below.

5. Set Length 2 to the maximum length by following the Maxicode Length 1, Length 2 Programming Instructions below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

Product Reference Guide

147

2D Symbologies

Maxicode — cont.

Maxicode Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to

Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing

the length.

For Maxicode labels, only the data characters are included in the length calculations.

Any value set higher than 138 will be considered to be 138.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 0138

148

Magellan TM 3200VSi

Aztec

Disable/Enable Aztec

When disabled, the scanner will not read Aztec labels.

START / END

PROGRAMMING bar codes

Disable Aztec

DEFAULT

Enable Aztec

2D Symbologies

Product Reference Guide

149

2D Symbologies

Aztec — cont.

Length Control

Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.

Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable Length 1 and Length 2 values.

Configuring Fixed Length Decoding:

1. Scan the START bar code.

2. Scan the Fixed Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming

Instructions below.

5. Set Length 2 to the second fixed length (or to ‘0000’ if there is only one fixed length) by following the

Aztec Length 1, Length 2 Programming Instructions below.

Configuring Variable Length Decoding:

1. Scan the START bar code.

2. Scan the Variable Length Decoding bar code.

3. Scan the END bar code.

4. Set Length 1 to the minimum length by following the Aztec Length 1, Length 2 Programming Instructions

below.

5. Set Length 2 to the maximum length by following the Aztec Length 1, Length 2 Programming Instructions

below.

START / END

PROGRAMMING bar codes

Variable Length Decoding

DEFAULT

Fixed Length Decoding

150

Magellan TM 3200VSi

2D Symbologies

Aztec — cont.

Aztec Length 1, Length 2 Programming Instructions

1. Scan the START bar code.

2. Scan either the Set Length 1 or Set Length 2 bar code.

3. Turn to

Appendix C, Alpha-Numeric Pad and scan the four digits (zero-padded) representing

the length.

For Aztec labels, only the data characters are included in the length calculations.

Any value set higher than 3700 will be considered to be 2710.

NOTE

Scan the END bar code.

START / END

PROGRAMMING bar codes

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 0001

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 2710

Product Reference Guide

151

2D Symbologies

Composite Labels

Disable/Enable GS1 DataBar Omnidirectional 2D Component

When enabled, if a GS1 DataBar Omnidirectional label is decoded which has the 2D linkage flag set, the 2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Omnidirectional base label will be decoded and transmitted regardless of the state of the linkage flag.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Omnidirectional 2D Component

DEFAULT

Enable GS1 DataBar Omnidirectional 2D Component

Disable/Enable GS1 DataBar Expanded 2D Component

When enabled, if a GS1 DataBar Expanded label is decoded which has the 2D linkage flag set, the 2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Expanded base label will be decoded and transmitted regardless of the state of the linkage flag.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Expanded 2D Component

DEFAULT

Enable GS1 DataBar Expanded 2D Component

152

Magellan TM 3200VSi

2D Symbologies

Disable/Enable GS1 DataBar Limited 2D Component

When enabled, if a GS1 DataBar Limited label is decoded which has the 2D linkage flag set, the

2D component must also be decoded or the base label will be discarded.

When disabled, only the GS1 DataBar Limited base label will be decoded and transmitted regardless of the state of the linkage flag.

START / END

PROGRAMMING bar codes

Disable GS1 DataBar Limited 2D Component

DEFAULT

Enable GS1 DataBar Limited 2D Component

Product Reference Guide

153

2D Symbologies

NOTES

154

Magellan TM 3200VSi

Advanced Decoding Features

Inverse Label Reading

This controls the method of reading inverse labels (white label on black background).

This feature is only available for GS1 DataBar and 2D symbologies.

NOTE

START / END

PROGRAMMING bar codes

2D Read Mode = Reads only normal labels

DEFAULT

2D Read Mode = Reads both normal and inverse labels

2D Read Mode = Reads only inverse labels

155

Product Reference Guide

Advanced Decoding Features

NOTES

156

Magellan TM 3200VSi

Optical and Read Performance Parameters

Parameter

Scan Volume

Minimum Resolution

Depth of Field

(100% UPC Labels)

Minimum Print Contrast Ratio

Skew (Yaw)

Pitch

Roll

Specification

250 cubic inches

5 mil

0 - 8” (0 - 20.32cm)

25%

± 75

ï‚°

± 65

ï‚°

Between 0 and 360

ï‚°

Scanner Dimensions

Appendix A

Product Specifications

6"

15.24cm

5.6"

14.22cm

3.3"

8.38cm

157

Product Reference Guide

Physical Properties

Parameter

Dimensions (Scanner only):

Weight (Scanner)

Specification

6” x 5.6” x 3.3” (WxHxD)

1 lb 4.6 oz (0.584kg)

Electrical Parameters

Parameter

Operating Voltage

Input Current @ 12 VDC

Operating (idle)

Operating (label read)

Specification

Input voltage 7 to 14 VDC

<190mA

<410 mA

Environmental Parameters

Parameter

Contaminants

Water and Dust

Temperature Ranges:

Operating

Storage

Ambient Light Indoor

Ambient Light Outdoor

Humidity

Beeper/Speaker

Vibration

Specification

IP5x

32

ï‚°

F to +104

ï‚°

F (0

ï‚°

C to +40

ï‚°

C)

-40

ï‚°

F to +158

ï‚°

F (-40

ï‚°

C to +70



C)

0 - 6,000 lux

0 - 86,100 lux

5% to 95% non-condensing

70-90dBA at a distance of 3’-3” (1 meter)

Retail/Office

Other Parameters

Parameter

EAS Support

Specification

YES (Checkpoint)

158

Magellan TM 3200VSi

Appendix B

Cable Pinouts

Standard Cable Pinouts (Primary Interface Cables)

Pin #

8

9

6

7

10

3

4

1

2

5

RS-232

DTR

CTS

RTS

RxD

TxD

VCC in

GND

IBM Port 5B/9B/17 USB-OEM

Line B

Line A

VCC in

GND

VBUS

D-

D+

+12V

GND

USB,

USB Keyboard,

USB COM

Keyboard Wedge

PCCLK

VBUS

D-

D+

VCC in

GND

KBCLK

PC Data

VCC in

GND

KBD

Cable Pinouts (Handheld Scanner Attached via the Aux Port)

PIN #

HANDHELD ATTACHED TO

AUX PORT

7

8

5

6

3

4

1

2

9

10

AUX_CTS

AUX_RTS

AUX_RxD

AUX_TxD

AUX_ERI

VCC

GND

159

Product Reference Guide

NOTES

160

Magellan TM 3200VSi

E

Product Reference Guide

A

C

Appendix C

Alpha-Numeric Pad

B

D

F

161

Alpha-Numeric Pad

1

3

5

9

7

162

2

4

6

8

0

Magellan TM 3200VSi

Appendix D

Factory Default Settings

Factory Defaults by Interface

The following is a partial list of key settings for each interface type.

FEATURE

Double Read Timeout for Linear Labels

Double Read Timeout for 2D Labels

Scanner Button Options

Camera Button Mode

LED Level

Auxiliary Port Mode

Auxiliary Port Baud Rate

Productivity Index Reporting (PIR)

Sleep Mode

LED and Beeper Indicators

Image Compression

Image Format

Image Size

Image Brightness

Image Contrast

Obey/Ignore Host Commands

Aux

60

(600ms)

1 Sec

Enable only vol, tone, and reset

RS-232

60

(600ms)

1 Sec

Enable only vol, tone, and reset

Wincor-

Nixdorf

60

(600ms)

1 Sec

Enable only vol, tone, and reset

Single

Cable

60

(600ms)

1 Sec

Enable only vol, tone, and reset

USB-OEM

60

(600ms)

1 Sec

Enable only vol, tone, and reset

Normal

Take Pix

Default

Level

Normal

Take Pix

Default

Level

Normal

Take Pix

Default

Level

Normal

Take Pix

Default

Level

Normal

Take Pix

Default

Level

Normal

Take Pix

Default

Level

Disable

19200

Disable

19200

Disable

19200

Disable

19200

Disable

19200

Disable

19200

Disable Disable Disable Disable Disable Disable

5 Minutes 5 Minutes 5 Minutes 5 Minutes 5 Minutes 5 Minutes

Enable

100

(minimum)

Enable

100

(minimum)

Enable

100

(minimum)

Enable

100

(minimum)

Enable

100

(minimum)

Enable

100

(minimum)

Keybd

Wedge

60

(600ms)

1 Sec

Enable only vol, tone, and reset

JPG

VGA

09

09

Disable

Obey

JPG

VGA

09

09

Disable

Obey

JPG

VGA

09

09

Disable

Obey

JPG

VGA

09

09

Disable

Obey

JPG

VGA

09

09

Disable

Obey

JPG

VGA

09

09

Disable

Obey

Product Reference Guide

163

FEATURE

Host Transmission Buffers

Baud Rate

Data Bits

Stop Bits

Parity

Hardware Flow Control

Intercharacter Delay

Software Flow Control

Host Echo

Host Echo Quiet Interval

Signal Voltage: Normal/TTL

RS-232 Invert

Beep on ASCII BEL

Beep on Not on File

ACK NAK Options

ACK Character

NAK Character

Retry on ACK NAK Timeout

ACK NAK Timeout Value

ACK NAK Retry Count

ACK NAK Error Handling

Transmission Failure Indication

Single Cable RS-232 Options

Single Cable RS-232 Use BCC

Single Cable RS-232 Use ACK/NAK

Single Cable RS-232 Use STX

Set Single Cable RS-232 STX Character

Single Cable RS-232 Use ETX

Aux

Disable

10 msec

Normal

RS-232

Disable

Enable

Enable

Disable

2

9600

8

1

None

Disable

No Delay

Disable

006

021

Enable

001

003

Ignore

Enable

Disable

Enable

Enable

Disable

006

021

Enable

001

RS-232

2

9600

8

1

None

Disable

Wincor-

Nixdorf

2

9600

8

1

None

Disable

No Delay No Delay

Disable Disable

Disable

10 msec

Normal

RS-232

Disable

10 msec

Normal

RS-232

003

Ignore

Enable

003

Ignore

Enable

Disable

Enable

Enable

Disable

006

021

Enable

001

No Delay

Disable

Disable

10 msec

Normal

RS-232

Disable

Enable

Enable

Disable

Single

Cable

2

9600

8

1

None

Disable

006

021

Enable

001

003

Ignore

Enable

RTS held high, wait for CTS to be asserted

Enable

Enable

Enable

53

Enable

USB-OEM

Disable

10 msec

Normal

RS-232

Disable

Enable

Enable

Disable

2

9600

8

1

None

Disable

No Delay

Disable

006

021

Enable

001

003

Ignore

Enable

No Delay

Disable

Disable

10 msec

Normal

RS-232

Disable

Enable

Enable

Disable

Keybd

Wedge

2

9600

8

1

None

Disable

006

021

Enable

001

003

Ignore

Enable

164

Magellan TM 3200VSi

Factory Defaults by Interface

FEATURE

Set Single Cable RS-232 ETX Character

Single Cable Pacesetter Plus

Single Cable Datalogic Extensions

USB-OEM Interface Features

IBM Transmit Labels in Code 39 Format

Keyboard Layout

Caps Lock State

Power-On Simulation

Control Characters

Wedge Quiet Interval

Intercharacter Delay

Global Prefix/Suffix

AIM ID

Label ID Position

Case Conversion

Character Conversion

Disable/Enable UPC-A

Check Digit Transmission

Number System Transmission

Expand UPC-A to EAN-13

Disable/Enable UPC-E

Check Digit Transmission

Number System Digit

Expand to UPC-E to UPC-A

Expand UPC-E to EAN13

Aux RS-232

Enable

Don’t

Expand

Enable

Send

Exclude

Don’t

Expand

Don’t

Expand

Prefix 00

Suffix 0D

Disable

Before barcode data

Disable

No Conversion

Enable

Send

Enable

Don’t

Expand

Enable

Send

Exclude

Don’t

Expand

Don’t

Expand

Prefix 00

Suffix 0D

Disable

Before barcode data

Disable

No Conversion

Enable

Send

Wincor-

Nixdorf

Enable

Don’t

Expand

Enable

Send

Exclude

Don’t

Expand

Don’t

Expand

Prefix 00

Suffix 0D

Disable

Before barcode data

Disable

No Conversion

Enable

Send

Enable

Don’t

Expand

Enable

Send

Exclude

Don’t

Expand

Don’t

Expand

Prefix 00

Suffix 0D

Disable

Before barcode data

Disable

No Conversion

Enable

Send

Single

Cable

0D

Disable

Disable

USB-OEM

Config as table top scanner

Disable

Keybd

Wedge

Enable

Don’t

Expand

Enable

Send

Exclude

Don’t

Expand

Don’t

Expand

Prefix 00

Suffix 0D

Disable

Before barcode data

Disable

No Conversion

Enable

Send

Disable

No Conversion

Enable

Send

Enable

Don’t

Expand

Enable

Send

USA

Disable

Disable

Disable

010

No Delay

Prefix 00

Suffix 0D

Disable

Before barcode data

Exclude

Don’t

Expand

Don’t

Expand

Product Reference Guide

165

Disable/Enable EAN-13

Check Digit Transmission

EAN-13 Flag 1 Character

ISBN

Disable/Enable EAN-8

Check Digit Transmission

Length Control

FEATURE

Expand UPC/EAN to GTIN

Expand EAN-8 to EAN-13

EAN Two-Label

EAN Two-Label Combined Transmission

Price Weight Check Digit

Add-ons

Disable/Enable GS1 DataBar Omnidirectional

UCC/EAN 128 Emulation

Disable/Enable GS1 DataBar Expanded

GS1-128 Emulation

Coupon Read Control

Disable/Enable GS1 DataBar Limited

GS1-128 Emulation

Disable/Enable Code 39

Check Character Calculation

Check Character Transmit

Start/Stop Characters

Code 39 Full ASCII

Aux

Don’t

Expand

Enable

Send

Transmit

Disable

Enable

Send

Don’t

Expand

Disable

Disable

Disable

Disable

RS-232

Don’t

Expand

Enable

Send

Transmit

Disable

Enable

Send

Don’t

Expand

Disable

Disable

Disable

Disable

Enable

Send

Don’t

Expand

Disable

Disable

Disable

Disable

Wincor-

Nixdorf

Don’t

Expand

Enable

Send

Transmit

Disable

Enable

Send

Don’t

Expand

Disable

Disable

Disable

Disable

Single

Cable

Don’t

Expand

Enable

Send

Transmit

Disable

USB-OEM

Don’t

Expand

Enable

Send

Transmit

Disable

Enable

Send

Don’t

Expand

Disable

Disable

Disable

Disable

Disable Disable Disable Disable Disable Disable

Disable

Disable

Disable

Variable

01/74

Enable

UPCA

Disable

GS1 Data-

Bar

Disable

Disable

Enable

Disable

Enable

Don’t

Transmit

Disable

Disable

Disable

Disable

Variable

01/74

Enable

UPCA

Disable

GS1 Data-

Bar

Disable

Disable

Enable

Disable

Enable

Don’t

Transmit

Disable

Disable

Disable

Disable

Variable

01/74

Enable

UPCA

Disable

GS1 Data-

Bar

Disable

Disable

Enable

Disable

Enable

Don’t

Transmit

Disable

Disable

Disable

Disable

Variable

01/74

Enable

UPCA

Disable

GS1 Data-

Bar

Disable

Disable

Disable

Disable

Enable

Don’t

Transmit

Disable

Disable

Disable

Disable

Variable

01/74

Enable

UPCA

Disable

GS1 Data-

Bar

Disable

Disable

Enable

Disable

Enable

Don’t

Transmit

Disable

Disable

Disable

Disable

Variable

01/74

Enable

UPCA

Disable

GS1 Data-

Bar

Disable

Disable

Enable

Disable

Enable

Don’t

Transmit

Disable

Enable

Send

Don’t

Expand

Disable

Disable

Disable

Disable

Keybd

Wedge

Don’t

Expand

Enable

Send

Transmit

Disable

166

Magellan TM 3200VSi

Factory Defaults by Interface

FEATURE

Length Control

Disable/Enable Code 32 Italian Pharmacode

Start/Stop Characters

Check Character Transmit

Disable/Enable Code 128

Disable/Enable EAN 128

Transmit Function Characters

Length Control

Code 128 Conversion to Code 39

Disable/Enable Interleaved 2 of 5

Check Digit Calculation

Check Digit Transmit

Length Control

Disable/Enable Codabar

Check Character Verification

Check Character Transmit

Length Control

Start/Stop Character Type

Start/Stop Character Transmission

Start/Stop Character Match

Disable/Enable Code 93

Length Control

Disable/Enable PDF 417

Length Control

Disable/Enable Micro PDF 417

Aux

Variable

02/50

RS-232

Variable

02/50

Wincor-

Nixdorf

Variable

02/50

Single

Cable

Variable

02/50

USB-OEM

Variable

02/50

Keybd

Wedge

Variable

02/50

Disable Disable Disable Disable Disable Disable

Variable

01/80

Disable

Disable

Disable

Disable

Variable

06/50

Don’t

Transmit

Enable

Enable

Disable

Don’t

Transmit

Variable

01/80

Disable

Disable

Disable

Disable

Variable

06/50

Don’t

Transmit

Enable

Enable

Disable

Don’t

Transmit

Variable

01/80

Disable

Disable

Disable

Disable

Variable

06/50

Don’t

Transmit

Enable

Disable

Disable

Don’t

Transmit

Variable

01/80

Disable

Disable

Disable

Disable

Variable

06/50

Don’t

Transmit

Enable

Enable

Disable

Don’t

Transmit

Variable

01/80

Disable

Disable

Disable

Disable

Variable

06/50

Don’t

Transmit

Enable

Enable

Disable

Don’t

Transmit

Disable

Disable

Disable

Variable

03/50

Disable

Disable

Disable

Variable

03/50

Disable

Disable

Disable

Variable

03/50

Disable

Disable

Disable

Variable

03/50

Disable

Disable

Disable

Variable

03/50

Disable

Disable

Disable

Variable

03/50 abcd/abcd abcd/abcd abcd/abcd abcd/abcd abcd/abcd abcd/abcd

Enable Enable Enable Enable Enable Enable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Variable

01/50

Enable

Variable

0001/2710

Disable

Variable

01/50

Enable

Variable

0001/2710

Disable

Variable

01/50

Enable

Variable

0001/2710

Disable

Variable

01/50

Enable

Variable

0001/2710

Disable

Variable

01/50

Enable

Variable

0001/2710

Disable

Variable

01/50

Enable

Variable

0001/2710

Disable

Variable

01/80

Disable

Disable

Disable

Disable

Variable

06/50

Don’t

Transmit

Enable

Enable

Disable

Don’t

Transmit

Product Reference Guide

167

Length Control

FEATURE

Disable/Enable Datamatrix

Length Control

Disable/Enable QR Code

Length Control

Disable/Enable Maxicode

Length Control

Disable/Enable Aztec

Length Control

Disable/Enable GS1 DataBar Omnidirectional 2D Component

Disable/Enable GS1 DataBar Expanded

2D Component

Disable/Enable GS1 DataBar Limited 2D

Component

Aux RS-232

Variable

0001/0366

Disable

Variable

0001/0800

Enable

Variable

0001/2710

Disable

Variable

0001/0138

Disable

Variable

0001/2710

Variable

0001/0366

Disable

Variable

0001/0800

Enable

Variable

0001/2710

Disable

Variable

0001/0138

Disable

Variable

0001/2710

Wincor-

Nixdorf

Variable

0001/0366

Disable

Variable

0001/0800

Enable

Variable

0001/2710

Disable

Variable

0001/0138

Disable

Variable

0001/2710

Single

Cable

Variable

0001/0366

Disable

Variable

0001/0800

Enable

Variable

0001/2710

Disable

Variable

0001/0138

Disable

Variable

0001/2710

USB-OEM

Variable

0001/0366

Disable

Variable

0001/0800

Enable

Variable

0001/2710

Disable

Variable

0001/0138

Disable

Variable

0001/2710

Keybd

Wedge

Variable

0001/0366

Disable

Variable

0001/0800

Enable

Variable

0001/2710

Disable

Variable

0001/0138

Disable

Variable

0001/2710

Disable Disable Disable Disable Disable Disable

Disable Disable Disable Disable Disable Disable

Inverse Label Reading

Disable

Reads normal only

Disable

Reads normal only

Disable

Reads normal only

Disable

Reads normal only

Disable

Reads normal only

Disable

Reads normal only

168

Magellan TM 3200VSi

Appendix E

Keyboard Function Key Mappings

Keyboard Model Cross Reference

Table E-1 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The

remaining tables in this chapter provide the function key maps associated with each of the scancode sets.

Table E-1. Keyboard Model Cross Reference

Model Type I/F ID

Transmission

Protocol

Scancode

Set

Func.

Key

Map

Support

Use

Country

Mode

PC/XT Foreign ALT Mode Wedge A PC/XT Scan Set 1 No

AT;

PS/2 25-286;

PS/2 30-286;

Wedge B AT/PS2 Scan Set 2 No

PS/2 50, 50Z;

PS/2 60,70,80,90,95

Foreign ALT Mode

PS/2 25 and 30

Foreign ALT Mode

PC/XT U.S. Mode

Wedge C

Wedge D

AT/PS2 Scan Set 1

PC/XT Scan Set 1

No

Yes

AT;

PS/2 25-286;

PS/2 30-286;

PS/2 50, 50Z;

PS/2 60,70,80,90,95

U.S. Mode + specific country support

PS/2 25 and 30

Wedge E

Wedge F

AT/PS2 Scan Set 2

AT/PS2 Scan Set 1

Yes

Yes

U.S. Mode

IBM 3xxx Terminals

(122-key keyboard)

IBM 3xxx Terminals

(102-key keyboard)

PS55 5530T with

JAPANESE DOS (TDOS)

Wedge G

Wedge H

Wedge I

AT/PS2 Scan Set 3

AT/PS2 Scan Set 3

AT/PS2

Japanese

DOS

Yes

Yes

Yes

NEC 9801 Wedge J

NEC

9801

NEC 9801 Yes

No

No

No

No

Yes

No

No

No

No

No

169

Product Reference Guide

Table E-2. USB Function Key Usage Map

02

03

04

05

06

07

14

15

16

17

10

11

12

13

0C

0D

0E

0F

08

09

0A

0B

1C

1D

1E

1F

18

19

1A

1B

ASCII Key value Usage Name

STX F11

ETX F12

EOT GUI right Make

ENQ

ACK

GUI right Break

CTRL right Make

BEL CTRL right Break

FS

GS

RS

US

CAN

EM

SUB

ESC

DLE

DC1

DC2

DC3

DC4

NAK

SYN

ETB

BS

HT

LF

VT

BS

TAB right

RIGHT arrow (inner keypad)

TAB left

FF Enter (right keypad)

CR CR

SO

SI

INSERT (inner keypad)

PAGE UP (inner keypad)

PAGE DOWN (inner keypad)

HOME (inner keypad)

LEFT arrow (inner keypad)

DOWN arrow (inner keypad)

UP arrow (inner keypad)

F6

F1

F2

F3

F4

F5

ESC

F7

F8

F9

F10

Modifier/

Scancode

00h 49h

00h 4Bh

00h 4Eh

00h 4Ah

00h 50h

00h 51h

00h 52h

00h 3Fh

00h 3Ah

00h 3Bh

00h 3Ch

00h 3Dh

00h 3Eh

00h 29h

00h 40h

00h 41h

00h 42h

00h 43h

80h 00h

00h 00h

1

10h 00h

00h 00h

1

00h 2Ah

00h 2Bh

00h 4Fh

02h 2Bh

00h 58h

170

Magellan TM 3200VSi

Table E-3. Scanset 1 Function Key Map

ASCII

(hex)

0E

0F

10

11

0A

0B

0C

0D

12

13

14

06

07

08

09

02

03

04

05

ASCII code Key

STX

ETX

EOT

ENQ

ACK

BEL

BS

HT

ALT left Make

ALT left Break

CTRL left Make

CTRL left Break

CTRL right Make

CTRL right Break

BS

TAB right

LF

VT

RIGHT arrow (inner keypad)

TAB left

FF Enter (inner keypad)

CR CR

SO

SI

DLE

DC1

INSERT (inner keypad)

PAGE UP (inner keypad)

PAGE DOWN (inner keypad)

HOME (inner keypad)

DC2

DC3

DC4

LEFT arrow (inner keypad)

DOWN arrow (inner keypad)

UP arrow (inner keypad)

Table E-4. Scanset 2 Function Key Map

ASCII

(hex)

16

17

18

19

12

13

14

15

1A

1B

1C

0E

0F

10

11

0A

0B

0C

0D

06

07

08

09

02

03

04

05

ASCII code

DC2

DC3

DC4

NAK

SYN

ETB

CAN

EM

SUB

ESC

FS

Key

STX

ETX

EOT

ENQ

ACK

BEL

BS

HT

ALT left Make

ALT left Break

CTRL left Make

CTRL left Break

CTRL right Make

CTRL right Break

BS

TAB right

LF

VT

RIGHT arrow (inner keypad)

TAB left

FF Enter (right keypad)

CR CR

SO

SI

DLE

DC1

INSERT (inner keypad)

PAGE UP (inner keypad)

PAGE DOWN (inner keypad)

HOME (inner keypad)

LEFT arrow (inner keypad)

DOWN arrow (inner keypad)

UP arrow (inner keypad)

F6

F1

F2

F3

F4

F5

ESC

F7

Product Reference Guide

Scancode

6Bh + E0

72h + E0

75h + E0

0Bh

05h

06h

04h

0Ch

03h

76h

83h

11h

F0h 11h

14h

F0h 14h

E0h 14h

E0h F0h 14h

66h

0Dh

74h + E0

0Dh + S

5Ah + E0

5Ah

70h + E0

7Dh + E0

7Ah + E0

6Ch + E0

Scancode

38h

B8h

1Dh

9Dh

E0h 1Dh

E0h 9Dh

0Eh

0Fh

4Dh + E0

0Fh + S

1Ch + E0

1Ch

52h + E0

49h + E0

51h + E0

47h + E0

4Bh + E0

50h + E0

48h + E0

Keyboard Model Cross Reference

171

1D

1E

1F

GS

RS

US

F8

F9

F10

0Ah

01h

09h

Table E-5 . Scanset 3, 102-Key Function Key Map

ASCII (hex) ASCII code

1A

1B

1C

1D

1E

1F

16

17

18

19

12

13

14

15

0E

0F

10

11

0A

0B

0C

0D

06

07

08

09

02

03

04

05

Key

SUB

ESC

FS

GS

RS

US

DC2

DC3

DC4

NAK

SYN

ETB

CAN

EM

STX

ETX

EOT

ENQ

ACK

BEL

BS

HT

ALT left Make

ALT left Break

CTRL left Make

CTRL left Break

CTRL right Make

CTRL right Break

BS

TAB right

LF

VT

RIGHT arrow (inner keypad)

TAB left

FF Enter (inner keypad)

CR CR

SO

SI

DLE

DC1

INSERT (inner keypad)

PAGE UP (inner keypad)

PAGE DOWN (inner keypad)

HOME (inner keypad)

LEFT arrow (inner keypad)

DOWN arrow (inner keypad)

UP arrow (inner keypad)

F6

F1

F2

F3

F4

F5

ESC

F7

F8

F9

F10

Scancode

27h

08h

37h

3Fh

47h

4Fh

61h

60h

63h

2Fh

07h

0Fh

17h

1Fh

19h

F0h 19h

11h

F0h 11h

58h

F0h 58h

66h

0Dh

6Ah

0Dh + S

79h

5Ah

67h

6Fh

6Dh

6Eh

172

Magellan TM 3200VSi

Table E-6. Scanset 3 122-Key Function Key Map

ASCII (hex) ASCII code

1A

1B

1C

1D

1E

1F

16

17

18

19

12

13

14

15

0E

0F

10

11

0A

0B

0C

0D

06

07

08

09

02

03

04

05

Key

STX ALT left Make

ETX ALT left Break

EOT CTRL left (RESET) Make only

ENQ CTRL left (RESET) Make/Break

ACK ONLINE Enter Make only

BEL ONLINE Enter Make/Break

BS

HT

BS

TAB right

LF

VT

RIGHT arrow (inner keypad)

TAB left

FF CR (FIELD EXIT) Make only

CR CR (FIELD EXIT) Make/Break

SO

SI

INSERT (inner keypad)

FIELD +

DLE FIELD -

DC1 HOME (inner keypad)

DC2 LEFT arrow (inner keypad)

DC3 DOWN arrow (inner keypad)

DC4 UP arrow (inner keypad)

NAK F6

SYN F1

ETB F2

CAN F3

EM F4

SUB F5

ESC ESC

FS

GS

F7

F8

RS

US

F9

F10

Scancode

27h

08h

37h

3Fh

47h

4Fh

61h

60h

63h

2Fh

07h

0Fh

17h

1Fh

19h

F0h 19h

11h

11h F0h 11h

58h

58h F0h 58h

66h

0Dh

6Ah

0Dh + S

5Ah F0h 5Ah

5Ah

65h

79h

7Ch

62h

Keyboard Model Cross Reference

Product Reference Guide

173

Table E-7. Japanese DOS Function Key Map

ASCII value

1Ah

1Bh

1Ch

1Dh

1Eh

1Fh

12h

13h

14h

15h

16h

17h

18h

19h

0Ah

0Bh

0Ch

0Dh

0Eh

0Fh

10h

11h

02h

03h

04h

05h

06h

07h

08h

09h

ASCII code

SUB

ESC

FS

GS

RS

US

DC2

DC3

DC4

NAK

SYN

ETB

CAN

EM

Key

STX

ETX

EOT

ENQ

ACK

BEL

BS

HT

ALT left Make

ALT left Break

CTRL left Make

CTRL left Break

CTRL right Make

CTRL right Break

BS

TAB right

LF

VT

RIGHT arrow (inner keypad)

TAB left

FF Enter (right keypad)

CR CR

SO

SI

DLE

DC1

INSERT (inner keypad)

PAGE UP (inner keypad)

PAGE DOWN (inner keypad)

HOME (inner keypad)

LEFT arrow (inner keypad)

DOWN arrow (inner keypad)

UP arrow (inner keypad)

F6

F1

F2

F3

F4

F5

ESC

F7

F8

F9

F10

Scancode

6Ch

3Dh

6Eh

6Fh

70h

71h

4Bh

4Ah

4Eh

6Dh

68h

69h

6Ah

6Bh

4Dh

3Ch + S

60h

3Bh

52h

49h

51h

4Ch

31h

B1h

41h

C1h

41h

C1h

3Eh

3Ch

174

Magellan TM 3200VSi

Table E-8. NEC 9801-Key Function Key Map

ASCII value

18h

19h

1Ah

1Bh

1Ch

1Dh

1Eh

1Fh

10h

11h

12h

13h

14h

15h

16h

17h

08h

09h

0Ah

0Bh

0Ch

0Dh

0Eh

0Fh

04h

05h

06h

07h

00h

01h

02h

03h

ASCII code Key Scancode

CAN

EM

SUB

ESC

FS

GS

RS

US

DLE

DC1

DC2

DC3

DC4

NAK

SYN

ETB

NUL unused

SOH CR

STX

ETX

CAPS LOCK ON (make)

CAPS LOCK OFF (break)

EOT

ENQ

ACK

BEL

CTRL left Make

CTRL left Break n/a

1Ch

71h

F1h

74h

F4h

CTRL-C 60h n/a n/a

BS

HT

LF

VT

BS

TAB right

RIGHT arrow (inner keypad)

TAB left

FF DELETE

CR CR

SO

SI

INSERT (inner keypad)

KATAKANA LOCK ON (Make)

0Eh

0Fh

3Ch

0Fh + S

39h

1Ch

38h

72h

KATAKANA LOCK OFF (Break)

HOME (inner keypad)

LEFT arrow (inner keypad)

DOWN arrow (inner keypad)

UP arrow (inner keypad)

F6

F1

F2

F3

F4

F5

ESC

F7

F8

F9

F10

64h

65h

66h

00h

68h

69h

6Ah

6Bh

F2h

3Eh

3Bh

3Dh

3Ah

67h

62h

63h

Keyboard Model Cross Reference

Product Reference Guide

175

NOTES

176

Magellan TM 3200VSi

Appendix F

Host Commands

Accepting RS-232 Commands

The scanner responds to the following RS-232 commands:

COMMAND

Enable Scanner

Disable

Scanner

Reset Scanner

Not On File

Indication

Beep Good

Read Tone

Force Good

Read Tone

Bel

Identification request

Health request

ASCII

E

D

R

F

B i

!

HEX

0x45

0x44

0x52

0x46

0x42

0x01

0x07

0x69 h 0x68

Status request s 0x73

1. Call Tech Support for information.

COMMENT

Long series of beeps

Beeps if Good Read Beep is enabled

Beeps regardless of beep setting

Force Good Read Tone

Returns long response

1

Returns long response

1

Returns long response

1

If one of the above commands is received, the scanner will perform the steps indicated for the command. Host commands for other interfaces are also available. Contact Tech Support for more details.

177

Product Reference Guide

NOTES

178

Magellan TM 3200VSi

1D Symbol Samples

UPC-A

0

0 1234567890

5

Code 128

Code 128

Code 39

BC321

Code 93

123456-9$

Product Reference Guide

Appendix G

Sample Symbols

Interleaved 2 of 5

1234567890

EAN-13

9 780330 290951

Codabar

A13579B

179

1D Symbol Samples — continued

GS1 DataBar Omnidirectional

(01)00123456789012

Code 2 of 5

123456

GS1 DataBar Expanded

0100123456789050

GS1 DataBar Limited

(01)16543210987654

180

Magellan TM 3200VSi

2D Sample Symbols

PDF 417

A12B3C

Datamatrix

1314H17LL

Maxicode

111TUVCCIUL7-1

Product Reference Guide

2D Sample Symbols

Micro PDF 417

BV17453

QR Code

35900G9

Aztec

This is an Aztec Code

181

Composite Sample Symbols

GS1 DataBar Limited Composite

GS1 DataBar Truncated Composite

182

Magellan TM 3200VSi

Appendix H microSD Card

microSDHC Compatibility

At the time of this writing, the micro SD card interface for this product supports SD-Memory Card Specifications/

Part 1. Physical Layer Specification; Version 1.01, but the processor MCI can communicate with SDHC Cards. For example, the scanner can perform the functions specified in this appendix for the SDA 2.0 specification.

microSD Card Insertion/Removal Indication

The scanner will audibly indicate insertion and removal of a micro SD card if the test port is not active or host commands are not in progress.

Autorun File Processing

After insertion of the card, the scanner will mount the micro SD card and search for the file “autorun.dls”. Embedded in that file is a validation pattern of the ASCII strings “$START$” and “$END$” located at the respective starting and ending of the file.

If the validation pattern is found, the file may contain any of the following commands. The scanner will parse the file taking action according to these commands. Filenames in italics specify a user-defined name.

Example autorun.dls file:

$START$ (required)

CARDINFO

CONFIG, filename.tex

DUMPSTATS, filename.txt

DUMPCFG, filename.tex

LOADSW, filename.bin

LOADHW, filename.vme

$END$ (required)

183

Product Reference Guide

microSD Function Summary

The following table summarizes various functions of micro SD card.

FUNCTION

Direction

Initiated by

Scanner



micro SD

Card micro SD Card



Scanner

Scanning a label

Autorun.dls file in micro

SD card

Image

Capture





Export

Status

Export

Configuration

Load

Applic







* Contact tech support for any available feature upgrade license.









Load

Config

Load

CPLD

Code

Feature

Upgrade*













microSD Function Details

From Scanner to microSD Card

Capture and save an image to a micro SD card by scanning a label.

1. Insert the micro SD card into the scanner

2. Scan the Capture Label

The scanner enters image capture mode.

3. Place the item to be captured in front of the scanner.

Press and release the Camera Button. The scanner will automatically capture and save the image to the micro

SD card.

4. Upon scanner audio indication of completion, an image is saved to the micro SD card.

NOTE

The image file name range is from image000 to image999. if the same name already exists in the micro SD card, the scanner skips that name and uses the next. For example, if image000.jpg is already used in the micro SD card, the scanner uses image001.jpg. The time stamp is not real, since scanner does not have a real time clock.

Image format (.bmp, .jpg), image size (VGA, WVGA, Full size), Brightness (0~9), contrast (0~9), and JPG compression ratio (0~100) are defined in configuration.

184

Magellan TM 3200VSi

Export a Configuration file from the Scanner to the micro SD card

By Autorun.dls file

1. Generate a text file by any text editor as follows and save it as autorun.dls

$START$

DUMPCFG,SDCONFIG.tex

$END$

2. Save or copy file autorun.dls to microSD card

3. Insert the microSD card to scanner

4. Wait for 3 seconds,

A scanner configuration file named SDCONFIG.txt is saved to the micro SD card.

Export Scanner Status to microSD card

The data includes scanner ID, statistics and scanner health.

By scanning a label

1. Insert the micro SD card into the scanner

2. Scan the status export label microSD Function Details

<FNC3>STATUS<CR>

3. Upon scanner audio indication of completion, the scanner status text file named status.txt is saved to the micro SD card.

Product Reference Guide

185

By Autorun.dls file

1. Generate a text file by any text editor as follows and save it as autorun.dls

$START$

DUMPSTATS,dmpstats.txt

$END$

2. Save or copy the autorun.dls file to the microSD card

3. Insert the micro SD card into the scanner

4. Wait for about 3 seconds.

A scanner statistics file named dmpstats.txt is saved to the microSD card.

From microSD Card to Scanner

Application code load to scanner

By Autorun.dls file

1. Generate a text file by any text editor as follows and save it as autorun.dls

$START$

LOADSW,R96-app1.bin

$END$

2. Step 2: Save or copy file autorun.dls to microSD card and copy the application code (example R96app1.bin) to the micro SD card.

3. Insert the micro SD card into the scanner.

4. Upon scanner audio indication of completion, the application code R96-app1.bin is loaded to the scanner.

Typically, this takes about 45 seconds.

CPLD code load to the scanner

By Autorun.dls file

1. Generate a text file using any text editor as follows, and save it as autorun.dls

$START$

LOADHW,090A.vme

$END$

2. Save or copy the autorun.dls file and copy the CPLD code (example 090A.vme) to the micro SD card.

3. Insert the micro SD card into the scanner

4. Upon scanner audio indication of completion, CPLD code 090A.vme is loaded to the scanner.

186

Magellan TM 3200VSi

microSD Function Details

Configuration load to scanner

By Autorun file

1. Generate a text file by any text editor as follows and save it as autorun.dls

$START$

CONFIG,R96-cfg1.tex

$END$

2. Save or copy the autorun.dls file, and copy the CPLD code (example R96-cfg1.tex) to the micro SD card

3. Insert the micro SD card into to the scanner

4. Upon scanner audio indication of completion, configuration R96-cfg1.tex is loaded to the scanner.

Product Reference Guide

187

NOTES

188

Magellan TM 3200VSi

Appendix I

Handheld Data Format Requirements

This appendix provides application notes to describe the general format of data that can be accepted by the scanner through the auxiliary port as transmitted from a handheld scanner.

Handheld Data Format Requirements General

• 9600 bps, 8 data bits, 1 stop bit, no parity.

• RTS is used to "bracket" the data received from the handheld: RTS must be asserted high during data transmission, and de-asserted after label transmission is complete. No other flow control mechanisms are required or supported.

• Symbologies requiring fixed lengths (UPC/EAN) will enforce length requirements for validation of the label.

• Handheld will be required to transmit start and stop characters for Codabar and Code 39 labels.

• Appropriate industrial length requirements will be enforced (if configured) for validation of the label.

• Maximum label lengths will be enforced for label validation (i.e. labels longer than the maximum label size will not be validated).

• Standard Datalogic formats generally use a single prefix character. The specific formats are provided below.

189

Product Reference Guide

Datalogic Handheld Data Format Requirements

The following sections describe label transmission formats that are typically observed in factory configurations of

Datalogic handheld scanners.

RSS-14

• Prefix must be ASCII characters ‘R4’

• Check character must be included in label

• Application identifier “01” must follow the prefix and preceed the base label

• Label length excluding prefix characters must be 16 characters.

• Example: ‘R40101044123456789’

RSS Expanded

• Prefix must be ASCII characters ‘R4’

• Check character must be included in label

UPC-A

• Number system must be included in label data.

• Check digit must be included in label data and is assumed to be correct.

• Prefix must be an ASCII character 'A' - total length including prefix must be 13.

• Example: 'A060992011187'.

UPC-A with 2-Digit Supplemental

• Number system must be included in label data.

• Check digit must be included in label data and is assumed to be correct.

• Supplemental data is appended to base label.

• Prefix must be an ASCII character 'A' - total length including prefix must be 15.

• Example: 'A06099201118712'.

UPC-A with 5-Digit Supplemental

• Number system must be included in label data

• Check digit must be included in label data and is assumed to be correct

• Prefix must be an ASCII character 'A' - total length including prefix must be 18

• Example: 'A06099201118712345'

UPC-A with Code 128 Supplemental

• Number system must be included in label data.

• Check digit must be included in label data and is assumed to be correct.

• Supplemental data is appended to base label.

190

Magellan TM 3200VSi

• Prefix must be an ASCII character 'A' - total length including prefix must be greater or equal to 19 Code 128

Supplemental codes are variable length having a minimum of 2 data characters).

• Characters immediately following base label must be of the form '8100', '8101' or '8102'.

• Example: 'A0609920111878100000951'.

UPC-E

• Number system must be included in label data

• Check digit must be included in label data and is assumed to be correct

• Prefix must be an ASCII character 'E' - total length including prefix must be 9

• Example: 'E09988750'

Product Reference Guide

191

UPC-E with 2-Digit Supplemental

• Number system must be included in label data.

• Check digit must be included in label data and is assumed to be correct.

• Supplemental data is appended to base label.

• Prefix must be an ASCII character 'E' - total length including prefix must be 11.

• Example: 'E0998875012'.

UPC-E with 5-Digit Supplemental

• Number system must be included in label data.

• Check digit must be included in label data and is assumed to be correct.

• Prefix must be an ASCII character 'E' - total length including prefix must be 14.

• Example: 'E0998875012345'.

UPC-E with Code 128 Supplemental

• Number system must be included in label data.

• Check digit must be included in label data and is assumed to be correct.

• Supplemental data is appended to base label.

• Prefix must be an ASCII character 'E' - total length including prefix must be greater or equal to 15 (code 128

Supplemental codes are variable length having a minimum of 2 data characters).

• Characters immediately following base label must be of the form '8100', '8101' or '8102'.

• Example: 'E099887508101000951'.

192

Magellan TM 3200VSi

EAN-8

• Check digit must be included in label data and is assumed to be correct

• Prefix must be an ASCII characters 'FF' - total length including prefix must be 10

• Example: 'FF00210126'

EAN-8 with 2-Digit Supplemental

• Check digit must be included in label data and is assumed to be correct.

• Supplemental data is appended to base label.

• Prefix must be an ASCII characters 'FF' - total length including prefix must be 12.

• Example: 'FF0021012612'.

EAN-8 with 5-Digit Supplemental

• Check digit must be included in label data and is assumed to be correct.

• Prefix must be an ASCII characters 'FF' - total length including prefix must be 15.

• Example: 'FF0021012612345'.

EAN-8 with Code 128 Supplemental

• Check digit must be included in label data and is assumed to be correct.

• Supplemental data is appended to base label.

• Prefix must be an ASCII characters 'FF' - total length including prefix must be greater than 16 (code 128

Supplemental codes are variable length having a minimum of 2 data characters).

• Characters immediately following base label must be of the form '8100', '8101' or '8102'.

• Example: 'FF002101268102000951'.

EAN-13

• Check digit must be included in label data and is assumed to be correct

• Prefix must be an ASCII character 'F'- total length including prefix must be 14

• Example: 'F1101234567891'

EAN-13 with 2-Digit Supplemental

• Check digit must be included in label data and is assumed to be correct

• Supplemental data is appended to base label

• Prefix must be an ASCII character 'F'- total length including prefix must be 16

• Example: 'F110123456789112'

EAN-13 with 5-Digit Supplemental

• Check digit must be included in label data and is assumed to be correct.

• Prefix must be an ASCII character 'F'- total length including prefix must be 19.

Product Reference Guide

193

• Example: 'F110123456789112345'.

EAN-13 with Code 128 Supplemental

• Check digit must be included in label data and is assumed to be correct

• Supplemental data is appended to base label

• Prefix must be an ASCII character 'F'- total length including prefix must be greater or equal to 20 (code 128

Supplemental codes are variable length having a minimum of 2 data characters)

• Characters immediately following base label must be of the form '8100', '8101' or '8102'

• Example: 'F11012345678918100000951'

Code 39

• Check character must be included in label data.

• Label length including start, stop and check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Start and stop characters "*" must be included in label.

• Prefix must be an ASCII character '*'.

• Example : '**Code 39.TEST*'.

Code 39-Pharmacode

• Check character must be included in label data.

• Label length including start, stop and check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Start and stop characters "*" must be included in label.

• Prefix must be an ASCII character 'p'.

• Example: 'p*123456789*'.

I 2 of 5

• Check character must be included in label data.

• Label length including check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Prefix must be an ASCII character 'i'.

• Example: 'i0123456789'.

194

Magellan TM 3200VSi

Codabar

• Check character must be included in label data.

• Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Prefix must be an ASCII character '%'.

• Start stop character sets must meet the matching requirement set forth by the scanner configuration item

Start/Stop Character Match .

• Start stop character sets must be of the form ABCD/ABCD and must be included in the label.

• Example: '%s$99.95s' (the lower case ‘s’ at each end of the example is a placeholder for the start stop character set).

Code 128

• Prefix must be an ASCII character '#'.

• Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Function characters may be transmitted as a hexadecimal value 8x. Where x correlates to function characters

1 thru 4 as follows:

• x80 = function code 1

• x81 = function code 2

• x82 = function code 3

• x83 = function code 4

• For Code 128 programming labels the format is of the general form '#/82nnnnn/r ' - /82 is hexadecimal 82 and /r is carriage return.

• Example: '#Code_128.Test'.

Product Reference Guide

195

MSI/Plessey

• Check character must be included in label data.

• Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Prefix must be an ASCII character '@'.

• Example: '@144769254'.

Code 93

• Prefix must be an ASCII character '&'.

• Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Example: '&Code93-test'.

PDF417

• Prefix must be an ASCII character 'P'.

• Label length excluding prefix character cannot exceed 300 characters. In addition to this, label length excluding prefix character must meet requirements imposed by the main scanner’s fixed or variable label length control for this symbology type.

196

Magellan TM 3200VSi

AIM Formats

AIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM specifies one identifier for UPC-A, UPC-E and EAN-13 labels, UPC-A, UPC-E and EAN-13 will be received from the handheld and transmitted by the scanner as EAN-13. The ']' character must be the first character received in the label transmission from the handheld.

The following sections describe the prefix strings and identify what specific label characteristics can be supported.

UPC-A

• AIM does not specify UPC-A as a separate symbology using this transmission format - labels will be transmitted as EAN-13.

• Example: ']E00060992011187'.

UPC-E

• AIM does not specify UPC-E as a separate symbology using this transmission format - labels will be transmitted as EAN-13.

• Example: ']E00000000998875'.

EAN-13

• Check digit must be included in label data and is assumed to be correct.

• Prefix must be ASCII characters ']E0'- total length including prefix must be 16.

• Example: ']E01101234567891'.

EAN-8

• Check digit must be included in label data and is assumed to be correct.

• Prefix must be ASCII characters ']E4' - total length including prefix must be 11.

• Example: ']E400210126'.

2-Digit Supplemental

• Supplemental data is appended to any EAN base label.

• Prefix must be ASCII characters ']E1'.

• length of Supplemental data including prefix must be 5. Total required length is 21 for EAN-13 and 16 for

EAN-8.

• Examples: addon portion is highlighted data is underlined.

UPC-A 2-Digit addon

UPC-E 2-Digit addon

EAN-8 2-Digit addon

EAN-13 2-Digit addon

']E00060992011187 ]E1 12 '

']E00000000998875 ]E1 12 '

']E400210126 ]E1 12 '

']E01101234567891 ]E1 12 '

Product Reference Guide

197

5-Digit Supplemental

• Supplemental data is appended to any EAN base label.

• Prefix must be ASCII characters ']E2'.

• Length of supplemental data including prefix must be 8. Total required length is 24 for EAN-13 and 19 for

EAN-8.

• Examples: addon portion is highlighted data is underlined.

UPC-A 5-Digit addon

UPC-E 5-Digit addon

EAN-8 5-Digit addon

EAN-13 5-Digit addon

']E00060992011187 ]E2 12345 '

']E00000000998875 ]E2 12345 '

']E400210126 ]E2 12345 '

']E01101234567891 ]E2 12345 '

198

Magellan TM 3200VSi

Code 128 Supplemental

• Supplemental data is appended to any EAN base label.

• Prefix must be ASCII characters ']C0'.

• length of Supplemental data including prefix is variable but must be at least 9.

• Examples: addon portion is highlighted data is underlined.

UPC-A Code 128 addon

UPC-E Code 128 addon

EAN-8 Code 128 addon

EAN-13 Code 128 addon

']E00060992011187 ]C0 81000009

51 '

'E00000000998875 ]C0 810000095

1 '

']E400210126 ]C0 8100000951 '

']E01101234567891 ]C0 81000009

51 '

Bookland

• The 'Bookland' / ISBN code will be formatted as a vendor specific AIM label.

• Prefix must be ASCII characters ']X0'.

• length of label data including prefix is 13.

• Examples: ']X01234567890'.

Code 39

• Check character must be included in label data.

• Label length including start, stop and check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Start and stop characters "*" must be included in label.

• Prefix must be ASCII characters ']A0' or ']A1'.

• Example: '*]A0Code 39.TEST*'.

Codabar

• Check character must be included in label data.

• Label length including check character and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Prefix must be ASCII characters ']F0'.

• Start stop character sets must meet the matching requirement set forth by the scanner configuration item

Start/Stop Character Match .

• Start stop character sets s must be of the form ABCD/ABCD and must be included in the label.

• Example: ']F0s$99.95s' (the lower case ‘s’ at each end of the example is a placeholder for the start stop character set).

Product Reference Guide

199

MSI/Plessey

• Check character must be included in label data.

• Label length including check character and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Prefix must be ASCII characters ']M0'.

• Example: ']M0144769254'.

Code 93

• Prefix must be ASCII characters ']G0'.

• Label length excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Example : ']G0Code93-test'.

200

Magellan TM 3200VSi

RSS-14

• Prefix must be ASCII characters ']e0'.

• Check character must be included in label.

• Label length excluding prefix characters must be 14 characters.

• Example: ']e001044123456789'.

RSS Expanded

• Prefix must be ASCII characters ']e0'.

• Label length excluding prefix characters must be at least 1 character. Maximum length is the maximum label size supported by the scanner.

• Example: ']e001900123456789083103001750'.

I 2 of 5

• Check character must be included in label data.

• Label length including check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• Prefix must be an ASCII character ']I1' (other prefixes specify different check character properties which are not supported).

• Example: ']I10123456789'.

Product Reference Guide

201

Code 128 / EAN128

• Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.

• Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.

• If EAN-128 Symbology is Enabled and prefix is ']C1', label will be identified as an EAN128 otherwise it is identified as a Code 128.

• A prefix of ']C0' designates that no function code is present in the 1st or 2nd character position.

• A prefix of ']C2' designates that a function code 1 is present in the 2nd character.

• Example : ']C0Code_128.Test'.

PDF417

• Prefix must be an ASCII characters ']L0'.

• Label length excluding prefix character cannot exceed 300 characters. In addition to this, label length excluding prefix character must meet requirements imposed by the main scanner’s fixed or variable label length control for this symbology type.

• Example : ']L0pdf_test_label'.

“Unknown” AIM ID (an AIM ID which is not specified above)

If a label is received that does not have an AIM ID as specified above, and the first three label characters qualify as follows...

• The first character is a ‘]’

• The second character is a capital or small letter

• The third character is a digit

...then the label type is set to GENERIC_DATA and the “unknown” AIM ID is left-appended to the beginning of the label data.

202

Magellan TM 3200VSi

ASCII Chart

Hex

No.

1C

1D

1E

1F

18

19

1A

1B

14

15

16

17

10

11

12

13

0C

0D

0E

0F

08

09

0A

0B

04

05

06

07

00

01

02

03

ASCII

Char.

CAN

EM

SUB

ESC

FS

GS

RS

US

DLE

DC1

DC2

DC3

DC4

NAK

SYN

ETB

FF

CR

SO

SI

BS

HT

LF

VT

NUL

SOH

STX

ETX

EOT

ENQ

ACK

BEL

Hex

No.

3C

3D

3E

3F

38

39

3A

3B

34

35

36

37

30

31

32

33

2C

2D

2E

2F

28

29

2A

2B

24

25

26

27

20

21

22

23

ASCII

Char.

>

?

<

=

;

:

8

9

6

7

4

5

2

3

0

1

/

.

-

,

*

+

)

(

&

$

%

SP

!

#

Hex

No.

5C

5D

5E

5F

58

59

5A

5B

54

55

56

57

50

51

52

53

4C

4D

4E

4F

48

49

4A

4B

44

45

46

47

40

41

42

43

ASCII

Char.

^

_

]

\

Z

[

X

Y

T

U

V

W

R

S

P

Q

L

M

N

O

J

K

H

I

D

E

F

G

@

A

B

C

ASCII

Char.

}

|

~

DEL z

{ x y v w t u r s p q n o l m k j h i f g d e b c

‘ a

Hex

No.

7C

7D

7E

7F

78

79

7A

7B

74

75

76

77

70

71

72

73

6C

6D

6E

6F

68

69

6A

6B

64

65

66

67

60

61

62

63

Australia

Datalogic Scanning Pty Ltd

Telephone: [61] (2) 9870 3200 [email protected]

France and Benelux

Datalogic Scanning SAS

Telephone: [33].01.64.86.71.00

[email protected]

Germany

Datalogic Scanning GmbH

Telephone: 49 (0) 61 51/93 58-0 [email protected]

India

Datalogic Scanning India

Telephone: 91- 22 - 64504739 [email protected]

Italy

Datalogic Scanning SpA

Telephone: [39] (0) 39/62903.1

[email protected]

Japan

Datalogic Scanning KK

Telephone: 81 (0)3 3491 6761 [email protected]

Latin America

Datalogic Scanning, Inc

Telephone: (305) 591-3222 [email protected]

Singapore

Datalogic Scanning Singapore PTE LTD

Telephone: (65) 6435-1311 [email protected]

Iberia

Datalogic Scanning SAS Sucursal en España

Telephone: 34 91 746 28 60 [email protected]

United Kingdom

Datalogic Scanning LTD

Telephone: 44 (0) 1582 464900 [email protected]

www.scanning.datalogic.com

Datalogic Scanning, Inc.

959 Terry Street

Eugene, OR 97402

USA

Telephone: (541) 683-5700

Fax: (541) 345-7140

©2010 Datalogic Scanning, Inc.

R44-3106 (Rev. D) October/2010

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents