Aube Technologies TH115-120GA Owner's Manual

Add to My manuals
4 Pages

advertisement

Aube Technologies TH115-120GA Owner's Manual | Manualzz

Thank you for choosing the AubeTH115 a programmable thermostat that provides both energy savings and comfort

TH115 -F-120GA

Owners Guide

Control Module Installation

Align the bracket tabs on the control module with the holes located on top of the power base.

Control module

F

Power base

NOTE:

Keep the thermostat’s air vents clean and free from obstructions.

NOTE:

The screw cannot be removed completely.

First Power ON

TH115 Description

Buttons and symbols

On/Stand By Switch

Use this switch to put the thermostat in sleep mode when its use is no longer required (e.g. summer).

This will not affect the clock programming.

GFCI Warning Light and Test Button

Day & Clock Settings

Programming Mode

Mode Selection/Exit Programming

Floor/Ambient (Amb. only with B)

Current Mode Auto, Manual, Vacation

Current Program Number

Setpoint definition/Pre-defined Setpoints

Increase/Decrease Temperature

When power is applied for the first time, the LCD dispays: 0:00, MO

(Monday), and temperature of the floor .

Press HOUR - MIN to set the current time.

Press DAY to set current day.

For AF and F models: one of the two following messages may be displayed if the installation is incorrect:

LO : The floor temperature is below

32ºF (0ºC), or the temperature sensor is defective, or not connected.

The heating indicator i is displayed and the relay is closed

(energized).

HI : The floor temperature is above

140°F (60°C), or the tempeature sensor is defective.

Correct

Incorrect

F

10103-A 04/08

24/7 Installation Support • Lifetime Technical Assistance • Free Design Service • www.WarmlyYours.com • (800) 875-5285

GFCI Test (GA & GB power baseonly)

The GFCI monitors the electrical flow for any loss of current; if there is one, the thermostat will cut off power to the heating system. We recommend you test the GFCI immediately after installing the control module, and once a month thereafter to ensure it is operating properly. To test:

Increase the temperature until the heating indicator is displayed.

Press TEST:

• Successful : the TEST warning light is ON and power to heating system is cut off.

• Unsucessful : the TEST warning light is OFF. Cut power to heating system from the main power panel and call customer service.

When successful, reset thermostat (Stand By/On) to power the heating system.

NOTE:

If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and have an electrician verify the installation.

Operating Modes

Automatic —

Executes the schedule.

F Press MODE until is displayed. The current program number is displayed.

You can temporary bypass the current program by setting a specific temperature or by pressing on a pre-defined setpoint button (

The new setpoint will be maintained until the begin-

) . ning of the next program.

Manual

—Maintains a constant temperature.

Press MODE until is displayed.

Set temperature or press ( pre-defined setpoint.

) to use

Vacation

—Maintains the Vacation setpoint during a prolonged absence.

Press until the icon is displayed.

F

F

Temperature Setpoint Pre-programed Schedule

The following temperature setpoints are pre-programmed:

Symbol Description

Default

A/AF F

Comfort ( when at home ) 70°F 82°F

Economy ( when asleep/ away from home )

Vacation ( during prolonged absence )

64°F

50°F

68°F

50°F

To modify a setpoint:

Set the desired temperature using .

Press and Hold the or or button until symbol is displayed.

Press RET to exit.

New

The TH115 programmable thermostat is pre-programmed with the following schedule:

F F F F

Time you wake up and desired temperature

Programs

Time you leave and temperature during your absence

Time you return home and desired temperature

Time you go to bed and overnight temperature

MO TU WE TH FR SA SU

6:00 6:00 6:00 6:00 6:00 6:00 6:00

8:30 8:30 8:30 8:30 8:30 --:---:--

16:00 16:00 16:00 16:00 16:00 --:---:--

23:00 23:00 23:00 23:00 23:00 23:00 23:00

Modify the Schedule

Notes:

You can program up to 4 different programs per day.

Each day can have different programs.

It is sometimes faster to program the same schedule for the entire week and then to modify the exception days.

To modify:

Press PGM to access the programming mode

Press DAY to select the day to be programmed (hold for 3 seconds to select all days of the week).

Press PGM to select the program number.

Press HOUR and MIN to set the time or press

CLEAR to clear the time (--:-- is disregarded).

Repeat steps 2 to 4 for remaining programs.

When completed, press RET to exit mode.

NOTE:

After 60 seconds of inactivity, the thermostat will automatically exit programming mode.

Custom Grid

Use this blank grid to record your new schedule.

Prog Setpoint MO TU WE TH FR SA

Model: A F AF

Temperature display: °F

Time display: 12hrs

°C

24hrs

SU

Temperature Control

The TH115 thermostat works differently than conventional electromechanical thermostats.

It is equipped with a proportional integral adaptive (P.I.A.) controller which determines heating cycles by analyzing the temperature behavior history within the room.

The P.I.A. controller reduces temperature variations providing an accurate temperature control while increasing user comfort.

The controller determines the amount of power required by the heating system to maintain the setpoint temperature.

1 to 20% 21 to 40% 41 to 60% 61 to 80% 81 to 100%

Technical Support

Model : TH115 A / AF / F

Display range : 32°F to 140°F (0°C to 60°C)

Setting range (ambient) : 40°F to 86°F (5°C to 30°C)

(AF only)

Setting range (floor limit) : 40°F to 104°F (5°C to 40°C)

Pre-programmed temperature setpoints :

Comfort : A/AF: 70°F (21°C) and F: 82°F (28°C)

Economy : A/AF: 64°F (18°C) and F: 68°F (20°C)

Vacation : A/F/AF: 50°F (10°C)

Floor limit : AF: 82°F (28°C)

Accuracy :± 0.9°F (0.5°C)

Storage :-4°F to 120°F (-20°C to 50°C)

Temperature control : Proportional integral adaptive,

15-minute or 15-second heating cycles according to the application and power base.

Memory backup : In the event of a power failure, an internal circuit will maintain the programming. Only the time will have to be set if the power failure is more than two (2) hours. The thermostat will return to the same operating mode as set before the power failure.

Warranty

AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.

The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation.

This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.

The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:

Aube Technologies Inc.

705 Montrichard

Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8

Technical Support

Model : TH115 A / AF / F

Display range : 32°F to 140°F (0°C to 60°C)

Setting range (ambient) : 40°F to 86°F (5°C to 30°C)

Setting range (floor limit) : 40°F to 104°F (5°C to 40°C)

Pre-programmed temperature setpoints :

Comfort : A/AF: 70°F (21°C) and F: 82°F (28°C)

Economy : A/AF: 64°F (18°C) and F: 68°F (20°C)

Vacation : A/F/AF: 50°F (10°C)

Floor limit : AF: 82°F (28°C)

Accuracy :± 0.9°F (0.5°C)

Storage :-4°F to 120°F (-20°C to 50°C)

Temperature control : Proportional integral adaptive,

15-minute or 15-second heating cycles according to the application and power base.

Memory backup : In the event of a power failure, an internal circuit will maintain the programming. Only the time will have to be set if the power failure is more than two (2) hours. The thermostat will return to the same operating mode as set before the power failure.

If you have any questions concerning the installation or programming of the TH115 programmable thermostat, call our technical support team at:

800.875.5285

For more information on our products, visit us at:

www.warmlyyours.com

As an E NERGY S TAR

®

partner, Aube Technologies has determined that this product meets the E NERGY S TAR guidelines for energy efficiency.

04/08/2003 920-115-007-00-1-A

Warranty

AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY

This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.

The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation.

This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.

The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:

Aube Technologies Inc.

705 Montrichard

Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8