Aube Technologies TH115 A/F/AF programmable thermostat offers precise temperature control and energy savings for your home. With its proportional integral adaptive (P.I.A.) controller, it analyzes temperature history to maintain a comfortable and consistent indoor climate. Program up to 4 daily schedules with different temperature settings for various times of the day and days of the week. The pre-programmed default schedule includes Comfort, Economy, and Vacation modes for easy setup. The large LCD display shows current and set temperatures, and the buttons allow for intuitive operation.
advertisement
Thank you for choosing the AubeTH115 a programmable thermostat that provides both energy savings and comfort
TH115 -F-120GA
Owners Guide
Control Module Installation
Align the bracket tabs on the control module with the holes located on top of the power base.
Control module
F
Power base
NOTE:
Keep the thermostat’s air vents clean and free from obstructions.
NOTE:
The screw cannot be removed completely.
First Power ON
TH115 Description
Buttons and symbols
On/Stand By Switch
Use this switch to put the thermostat in sleep mode when its use is no longer required (e.g. summer).
This will not affect the clock programming.
GFCI Warning Light and Test Button
Day & Clock Settings
Programming Mode
Mode Selection/Exit Programming
Floor/Ambient (Amb. only with B)
Current Mode Auto, Manual, Vacation
Current Program Number
Setpoint definition/Pre-defined Setpoints
Increase/Decrease Temperature
When power is applied for the first time, the LCD dispays: 0:00, MO
(Monday), and temperature of the floor .
Press HOUR - MIN to set the current time.
Press DAY to set current day.
For AF and F models: one of the two following messages may be displayed if the installation is incorrect:
LO : The floor temperature is below
32ºF (0ºC), or the temperature sensor is defective, or not connected.
The heating indicator i is displayed and the relay is closed
(energized).
HI : The floor temperature is above
140°F (60°C), or the tempeature sensor is defective.
Correct
Incorrect
F
10103-A 04/08
24/7 Installation Support • Lifetime Technical Assistance • Free Design Service • www.WarmlyYours.com • (800) 875-5285
GFCI Test (GA & GB power baseonly)
The GFCI monitors the electrical flow for any loss of current; if there is one, the thermostat will cut off power to the heating system. We recommend you test the GFCI immediately after installing the control module, and once a month thereafter to ensure it is operating properly. To test:
Increase the temperature until the heating indicator is displayed.
Press TEST:
• Successful : the TEST warning light is ON and power to heating system is cut off.
• Unsucessful : the TEST warning light is OFF. Cut power to heating system from the main power panel and call customer service.
When successful, reset thermostat (Stand By/On) to power the heating system.
NOTE:
If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and have an electrician verify the installation.
Operating Modes
Automatic —
Executes the schedule.
F Press MODE until is displayed. The current program number is displayed.
You can temporary bypass the current program by setting a specific temperature or by pressing on a pre-defined setpoint button (
The new setpoint will be maintained until the begin-
) . ning of the next program.
Manual
—Maintains a constant temperature.
Press MODE until is displayed.
Set temperature or press ( pre-defined setpoint.
) to use
Vacation
—Maintains the Vacation setpoint during a prolonged absence.
Press until the icon is displayed.
F
F
Temperature Setpoint Pre-programed Schedule
The following temperature setpoints are pre-programmed:
Symbol Description
Default
A/AF F
Comfort ( when at home ) 70°F 82°F
Economy ( when asleep/ away from home )
Vacation ( during prolonged absence )
64°F
50°F
68°F
50°F
To modify a setpoint:
Set the desired temperature using .
Press and Hold the or or button until symbol is displayed.
Press RET to exit.
New
The TH115 programmable thermostat is pre-programmed with the following schedule:
F F F F
Time you wake up and desired temperature
Programs
Time you leave and temperature during your absence
Time you return home and desired temperature
Time you go to bed and overnight temperature
MO TU WE TH FR SA SU
6:00 6:00 6:00 6:00 6:00 6:00 6:00
8:30 8:30 8:30 8:30 8:30 --:---:--
16:00 16:00 16:00 16:00 16:00 --:---:--
23:00 23:00 23:00 23:00 23:00 23:00 23:00
Modify the Schedule
Notes:
You can program up to 4 different programs per day.
Each day can have different programs.
It is sometimes faster to program the same schedule for the entire week and then to modify the exception days.
To modify:
Press PGM to access the programming mode
Press DAY to select the day to be programmed (hold for 3 seconds to select all days of the week).
Press PGM to select the program number.
Press HOUR and MIN to set the time or press
CLEAR to clear the time (--:-- is disregarded).
Repeat steps 2 to 4 for remaining programs.
When completed, press RET to exit mode.
NOTE:
After 60 seconds of inactivity, the thermostat will automatically exit programming mode.
Custom Grid
Use this blank grid to record your new schedule.
Prog Setpoint MO TU WE TH FR SA
Model: A F AF
Temperature display: °F
Time display: 12hrs
°C
24hrs
SU
Temperature Control
The TH115 thermostat works differently than conventional electromechanical thermostats.
It is equipped with a proportional integral adaptive (P.I.A.) controller which determines heating cycles by analyzing the temperature behavior history within the room.
The P.I.A. controller reduces temperature variations providing an accurate temperature control while increasing user comfort.
The controller determines the amount of power required by the heating system to maintain the setpoint temperature.
1 to 20% 21 to 40% 41 to 60% 61 to 80% 81 to 100%
Technical Support
Model : TH115 A / AF / F
Display range : 32°F to 140°F (0°C to 60°C)
Setting range (ambient) : 40°F to 86°F (5°C to 30°C)
(AF only)
Setting range (floor limit) : 40°F to 104°F (5°C to 40°C)
Pre-programmed temperature setpoints :
Comfort : A/AF: 70°F (21°C) and F: 82°F (28°C)
Economy : A/AF: 64°F (18°C) and F: 68°F (20°C)
Vacation : A/F/AF: 50°F (10°C)
Floor limit : AF: 82°F (28°C)
Accuracy :± 0.9°F (0.5°C)
Storage :-4°F to 120°F (-20°C to 50°C)
Temperature control : Proportional integral adaptive,
15-minute or 15-second heating cycles according to the application and power base.
Memory backup : In the event of a power failure, an internal circuit will maintain the programming. Only the time will have to be set if the power failure is more than two (2) hours. The thermostat will return to the same operating mode as set before the power failure.
Warranty
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation.
This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.
The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:
Aube Technologies Inc.
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8
Technical Support
Model : TH115 A / AF / F
Display range : 32°F to 140°F (0°C to 60°C)
Setting range (ambient) : 40°F to 86°F (5°C to 30°C)
Setting range (floor limit) : 40°F to 104°F (5°C to 40°C)
Pre-programmed temperature setpoints :
Comfort : A/AF: 70°F (21°C) and F: 82°F (28°C)
Economy : A/AF: 64°F (18°C) and F: 68°F (20°C)
Vacation : A/F/AF: 50°F (10°C)
Floor limit : AF: 82°F (28°C)
Accuracy :± 0.9°F (0.5°C)
Storage :-4°F to 120°F (-20°C to 50°C)
Temperature control : Proportional integral adaptive,
15-minute or 15-second heating cycles according to the application and power base.
Memory backup : In the event of a power failure, an internal circuit will maintain the programming. Only the time will have to be set if the power failure is more than two (2) hours. The thermostat will return to the same operating mode as set before the power failure.
If you have any questions concerning the installation or programming of the TH115 programmable thermostat, call our technical support team at:
800.875.5285
For more information on our products, visit us at:
www.warmlyyours.com
As an E NERGY S TAR
®
partner, Aube Technologies has determined that this product meets the E NERGY S TAR guidelines for energy efficiency.
04/08/2003 920-115-007-00-1-A
Warranty
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation.
This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product.
The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address:
Aube Technologies Inc.
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8
advertisement