Chuango G5 User Manual
Add to My manuals29 Pages
Chuango G5 is an advanced GSM/SMS/RFID security alarm system that provides reliable home protection with features like two-way communication, remote monitoring, and multiple arming options. It supports 50 wireless sensors, 10 remote controls, 50 RFID tags, and allows for customization of zone names and SMS alerts. The built-in speaker and microphone enable real-time conversations with visitors or intruders, while the system's compatibility with RFID tags permits keyless entry and automatic door unlocking.
advertisement
Printed in Hong Kong
PA: OI-G5-EN-1309-V2.2-UK
GSM/SMS/RFID
Security Alarm System
Features
ARM + Auror CPU
Support 10 remote controls, 50 wireless sensors and 50 RFID tags
Built-in 1,000,000 RF codes combination maintains high reliability
Cellular communicator, simple operation
Store 5 phone numbers, 1 speed-dial number, and 1 RFID SMS notification number
Exit and entry delay
SMS alert for low battery of two-way accessories
Arm and disarm the system by SMS or free phone call
Remote monitoring site via phone
Firewall to prevent operation from unauthorized users
Built-in loud speaker for siren and two-way talking
Built-in two pieces of 800mAh lithium batteries enable 5-hour standby
SMS alerts for power failure, power recovery and low battery
850/900/1800/1900MHz GSM frequency, applicable for universal
Table of Contents
Included Accessories
Control Panel Layout
Record/Play Voice Memo
RFID Tag
Speed Dial
Phone Call
Recording Alarm Message
Electronic Lock Output
SMS Operation
Disarm
Arm
Stay Arm (Home Mode)
Two-Way Talk
Call-Back to Record Voice Memo
Settings Inquir y
Store Alarm Phone No.
Store Alarm SMS No.
Store SMS No. for RFID Tags
Store Speed Dial Phone Number
Change Zone Name
SMS Alert for Low Batter y of Accessories
1~2
3 ~ 5
6
8
9~29
8
8
7
7
SMS Alert for Tamper Alarm of Accessories
Change RFID Tags SMS Notice
Entr y and Exit Delay Time
Siren Volume and Ringing Time
Disarm Password
Single Zone Delay Time
Change System Language
Delete Wireless Sensors
Delete RFID Tags
Delete Remote Controls
Restore System to Default Setting
Alarm Notification Ways
Phone Remote Control Instruction
Test Mode
Arm & Disarm by Free Phone Call
Connect Wireless Accessories & RFID Tags
Connect Wireless Siren
Specifications
Wireless Remote Control
Wireless Door/Window Contact
Wireless PIR Motion Detector
Zone Setup for Wireless Sensors
32
32
33
34~36
37~40
41~49
50
30
30
31
31
Included Accessories
CG-G5 Control Panel x 1
The control panel is known as the “hear t and brain” for alarm system, which is used for receiving and processing signals from wireless sensors and remote controls. Users can make settings freely by
GSM cell phone and Apps. In case of emergency, the panel rings on site and dials the pre-stored alarm phone numbers automatically. When users pick up the phone, they are able to hear the voice recording aler t and choose to monitor on site or disarm the system.
*Input keywords “G5” in Google Play or App Store to download free App for remote controlling and setting the alarm system anytime and anywhere.
Wireless PIR Motion Detector x 1
The wireless PIR Motion Detector is an intelligent passive infrared motion sensor, designed to detect human movements within an approximate range of 6 to 8 meters from the detector. The detector includes fuzzy logic to minimize false alarms from unwanted heat sources. With power saving feature, the detector will enter sleeping mode after the second activation within 3 minutes to save power.
TAG-26 RFID Tag x 2
The RFID tag is for disarming
The system and unlocking the electronic door lock (if connected).
AC Adapter x 1
Supply power to the control panel. In case of power failure, two built-in backup batteries in the panel will support 5-hour standby.
Brackets (wall-mounted and desktop) for control panel x 2
Bracket for PIR Motion
Detector x 1
Screws and wall plugs x 4
1
Wireless Door/Window Contact x 1
The Door/window contact can be installed on doors, windows and any other objects that open and close.
The sensor transmits signals to the control panel when a magnet mounted near the sensor is moved away.
Wireless Remote Control x 2
The remote control is compact and portable; it is convenient to carry it to arm, disarm, part arm the alarm system and also make an emergency call.
Double-sided tape for
Door/Window Contact x 1
User Manual x 1
2
Control Panel Layout
GSM Signal Indicator
GSM network searching: Flashes once every second
GSM signal in normal: Flashes once every two seconds
Touch Keypad
Status Indicator
3
Arm
Disarm
Call
RFID Reader / Play Voice Memo
Stay Arm (Home Mode)
Record Voice Memo /
Connect Button
Arm
Press to arm the system.
Home mode
Press to arm the sytem in home mode.
All the sensors in Normal Zone are armed except those in
Home Mode Zone which are disarmed so that user can move freely at home.
Disarm on keypad:
Input 4 digits password (default:1234) , and press to disarm the system after one beep.
If three beeps are heard, password is wrong and please input again.
Disarm by RFID tag:
Induce the RFID tag to the RFID Reader area to disarm the system.
4
Rear Side
MIC Buzzer Tamper Switch Loudspeaker
Record / Play Voice Memo
Press for 2 seconds to record 10 seconds voice messages.
Or send SMS to system for calling back to record the voice messages. The Play Voice Memo Button will be flashing in green to remind you. Users can touch the center of circle to listen to the voice memo. The LED indicator blacks out when the voice memo is played. Replay by touching it again.
5
SIM Card Slot
Back-up Batteries
Input for Wired Sensors
(24-hour zone)
Input for Wired Sensors
(normal zone)
Output for
Electronic Lock
Output for Wired Siren
≤ 500mA
Adapter Interface
Power On/Off
6
RFID Tag
The RFID tag is for disarming the system and unlocking the electronic door lock (if connected).
You can rename the RFID tags and store a mobile phone number to send SMS notice when family members come home and disarm the system.
Nancy
Nancy came home
7
Mom
Administrator
Note!
Only after SMS No. is stored, and the RFID tags SMS notice is changed (4 RFID tags can be renamed), users can receive notice SMS once someone disarms the system by RFID tag.
Speed Dial
Press Call Button , the panel auto dials to pre-stored phone number of the host, the LED blacks out after talk.
User can also press Call Button to end talk.
Phone Call
Dial phone number and then press Call Button to start talk, the LED blacks out after talk.
User can also press Call Button to end talk.
Recording Alarm Message
Make sure the panel is in home mode. Input passcode, and then press the button and button on the panel, the LED light of button is on, the panel starts 10 seconds recording of the alarm message.
When the alarm message is recorded, user will firstly hear the alarm message when picking up the phone call from the panel. Then, user can start remote control the control panel.
See detailed instruction in Page 30.
Electronic Lock Output
When system is disarmed, the output signal opens electronic lock automatically.
8
9
SMS Operation
Insert a SIM card to the control panel, then send a text of “?” to the SIM card number, the operation guide message will be replied.
You can control the alarm system by following the guide message:
Send:
?
System replies first grade guide menu:
‘0’ Disarm
‘1’ Arm
‘2’ Home mode
‘3’ Two-way talk
‘4’ Call-back voice memo
‘00’ Settings inquiry
‘??’ Store phone and SMS No.
Send:
??
System replies second grade guide menu:
‘5’ Store alarm phone No.
‘6’ Store alarm SMS No.
‘7’ Store SMS No. for RFID tags
‘8’ Store speed dial phone No.
‘???’ System setups
Send:
???
System replies third grade guide menu:
‘91~99’ Zone name
‘10’ RFID tags SMS notice
‘11’ Entry and exit delay time
‘12’ Siren volume and ringing time
‘13’ Disarm password
‘14’ Single zone delay time
10
11
Disarm
Send:
0
System disarmed.
Arm
Send:
1
System armed.
Stay Arm (Home Mode)
Send:
2
System in home mode.
12
Two-Way Talk
Send:
3
Send ‘3’ to the SIM card number, the alarm will call back.
Pick up the phone and start two-way talk.
Call-Back to Record Voice Memo
Send:
4
13
Send ‘4’ to the SIM card number, the alarm will call back.
Pick up the phone, and leave 10 seconds message.
The panel will hang up after 10 seconds.
Settings Inquiry
Send:
00
System status
Entry and exit delay time: 0sec
Single zone delay time: 30sec
Siren volume: 2
Siren ringing time: 5min
Disarm password: 1234
Note:
Value of default setting will be changed once users finish programming.
14
Store Alarm Phone No.
Send:
5
TEL:
1.
2.
3.
4.
5.
15
For ward > Edit
TEL:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.
Store alarm phone No.
successfully.
Special Tips:
Firewall feature is adopted to prevent nonstored phone no. and SMS no. to remote control the system and change settings.
Store Alarm SMS No.
Send:
6
SMS:
1.
2.
3.
4.
5.
For ward > Edit
SMS:
1. 67890033
2. 67890022
3. 67890011
4. 67890000
5.
Store alarm SMS No. successfully.
Special Tips:
Please edit on the basis of the replied text and don't change the format. Other wise, the system will not recognize the command.
16
Store SMS No. for RFID Tags
Send:
7
SMS No. for RFID tags
(0-20 digits):
1.
For ward > Edit
SMS No. for RFID tags
(0-20 digits):
1. 67890033
Store SMS No. for RFID tags successfully.
17
Note: Only after SMS No. is stored, and the RFID tags
SMS notice is changed, users can receive notice SMS once someone disarms the system by RFID tag.
Store Speed Dial Phone Number
Send:
8
Speed dial phone number
(0-20 digits):
1.
For ward > Edit
Speed dial phone number
(0-20 digits):
1. 67890033
Store speed dial phone number successfully.
18
19
Change Zone Name
Special Tips!
th
30 English characters at most for each line due to SMS character limit.
Other alarm zones are fixed as Zone 10 alarm, Zone 11 alarm and so on.
Send: 91~99
9 1
Zone1 name: Zone 1 alarm
For ward > Edit
Zone1 name: Entrance door sensor
Change zone name successfully.
SMS Alert for Low Battery of Accessories
(available for two-way accessories such as DWC-102 and PIR-900/910)
SMS will be sent for 1-9 zones with its zone name as
“Zone name + low battery”.
Bedroom PIR low battery.
SMS alert for 10~50 zones will be “Zone number + low battery”.
Zone 10 low battery.
SMS Alert for Tamper Alarm of Accessories
(available for two-way accessories such as DWC-102 and PIR-900/910)
SMS will be sent for 1-9 zones with its zone name as
“Zone name + tamper alarm”.
Bedroom PIR tamper alarm.
SMS alert for 10~50 zones will be “Zone number + tamper alarm”.
Zone 10 tamper alarm.
20
Change RFID Tags SMS Notice
Send:
10
Change RFID tags SMS notice:
1.
2.
3.
4.
21
For ward > Edit
Change RFID tags SMS notice successfully.
Change RFID tags SMS notice:
1. Tom
2. Nurse
3. Nancy
4. David
Note:
Only after SMS No. is stored, and the RFID tags SMS notice is changed, users can receive notice
SMS once someone disarms the system by RFID tag.
Entry and Exit Delay Time
Send:
11
Entry and exit delay time
(0-300 sec.):
0
For ward > Edit
Entry and exit delay time
(0-300 sec.):
10
Set delay time successfully.
Notice!
If users don’t want to take remote control or RFID cards with them, this function can be used. Once the delay time is set, when you arm the system, one beep will be heard every second to remind the user to leave.
The reminding rhythm will be speeded up in the last 15 seconds.
Once the intruder is detected, the alarm will be delayed accordingly.
22
23
Siren Volume and Ringing Time
Send:
12
Siren volume(0 Mute,
1 Low, 2 High):
2
Siren ringing time(1-9min):
5
For ward > Edit
Siren volume(0 Mute,
1 Low, 2 High):
1
Siren ringing time(1-9min):
3
Set siren volume and ringing time successfully.
Disarm Password
Send:
13
Disarm password(4-6 digits):
1234
For ward > Edit
Disarm password(4-6 digits):
8888
Set disarm password successfully.
24
25
Single Zone Delay Time
Send:
14
Single zone delay time (0-300 sec.):
30
For ward > Edit
Single zone delay time (0-300 sec.):
15
Set single zone delay time successfully.
Change System Language
Send: 0086 to change language to be Chinese
0086
中文语言修改成功!
Send: 0001 to change language to be English
0001
Set English successfully.
26
27
Delete Wireless Sensors
Send:
21
Delete wireless sensors successfully.
Delete RFID Tags
Send:
22
Delete RFID tags successfully.
Delete Remote Controls
Send:
23
Delete remote controls successfully.
Note:
Press Tamper Switch 3 times within 3 seconds, all wireless sensors,
RFID tags, and remote controls will be deleted after two beeps.
28
29
Restore System to Default Setting
Send:
0000
System has been restored to factory settings.
Or press Tamper Switch 5 times within 3 seconds, the system will be restored to factor y settings after two beeps.
Note:
After programming, only stored numbers can send SMS to restore the system.
Alarm Notification Ways
Once the alarm system is triggered , the control panel will send SMS in turns , and then will make calls in turns . The first round of dialing , each stored phone number will get the phone call . From the second round , as long as one user picks up the phone , the control panel will stop dialing to next number .
Phone Remote Control Instruction
User can control the alarm system by phone only when receiving an alarm call for an emergency event.
Operation
Press 1
Press 0
Press 9
Press 6
Press
Press #
Function
Arm the system
Disarm the system
Turn on siren
Turn off siren
Two-way talk
Re-play recorded alarm voice message
Illustration
Deter the intruder
If it is not heard clearly
30
31
Test Mode
Press the Disarm button on the panel for 3 times, the system enters Test Mode for 10 minutes after a long beep.
During this period, the panel will not alarm but give out three beeps when the tamper switch or the sensors connected are triggered.
Press the Arm button on the panel to exit Test Mode.
Arm & Disarm by Free Phone Call
Arm
Call the control panel number, hang up when hearing the ring tone. The panel will call back. The user hangs up the phone directly to arm the system.
Disarm
Call the control panel number, hold on until the panel hangs up the call. The panel will not call back. System is disarmed.
Connect Wireless Accessories & RFID Tags
Input 4-6 digits password, press Connect Button , the LED indicator lights up, then trigger the accessory or RFID tag once within 15 seconds, the connection is successful after a beep.
Once two beeps are heard, the accessory has been connected before. The first connected accessory is in Zone 1, the second one in Zone 2, and so on.
Connect Wireless Siren
The newly-added wireless siren can be used after connecting to the control panel.
Operation:
Press the Connect Button of the wireless siren for 0.5 second, the Connect Button LED indicator lights on, and then press the
Arm Button on the control panel, the siren will be connected after one beep is heard.
Testing: Press the Arm Button on the remote control, to make sure that the internal siren and wireless siren both beep once, the connection is successful. If not, the connection fails, please reconnect them.
Once the intruder is detected, both internal siren and wireless siren will hoot to deter the illegal intruder. (The siren will be off in 5 minutes as the default setting). At the same time, the alarm system will send SMS and auto dial to users.
32
33
Specifications
Product name : GSM/SMS/RFID Security Alarm System
Model No. : CG-G5
Control panel’s power supply :
Input: AC 110-240V, 50/60Hz
Output: DC 12V 500mA
GSM working frequency : 850/900/1800/1900MHz
Standby current : 110mA
Alarm current : 340mA
Internal battery backup :
Lithium Battery : 3.7V 800mAh x 2 PCS (BL-5B)
Internal siren : 95dB
Allowed amount of expandable wireless accessories :
10pcs remote controls, 50pcs wireless sensors and 50pcs RFID tags.
Radio frequency : 315MHz or 433MHz (±75KHz)
Housing material : ABS plastic
Operation condition:
Temperature: -10ºC~55 ºC
Humidity: ≤ 80% RH (non-condensing)
Size (L x W x H) : Panel : 188×132×26mm
Wireless Remote Control
Arm
Arm
Stay
LED Indicator
Disarm
Panic
Press {Arm } to arm the alarm panel and the LED indicator lights on (siren hoots once), the system enters Arm state.
If there comes an intruder, the siren will hoot to deter the intruder.
(The siren turns off after ringing for 5 minutes as default setting.)
At the same time, the system dials the pre-stored phone numbers automatically.
34
Disarm Mute Mode
Press {Disarm } to disarm the alarm panel and the LED indicator blacks out (siren hoots twice), the system is disarmed.
When intruders are detected, siren will keep hooting. Press
{Disarm } to stop siren hooting.
Home Mode
Press {Stay } button on the remote control, then press button, the siren keeps silent to finish the operation. The system is armed or disarmed in mute without disturbing other people.
Emergency Call
35
Press {Stay } button on the remote control, the system state
LED is on. All the sensors in Normal Zone are armed except the motion detector in Home Mode Zone which is disarmed so that user can move freely at home.
No matter what state the control panel is in, once SOS button on the remote control is pressed, the system immediately goes into emergent alarming state.
36
37
Wireless Door/Window Contact
Features
The DWC- 102 is a Door/Window Contact (Two-way) that can be installed on doors, windows, and any other objects that open and close. The sensor transmits signals to the control panel when a mag net mou nted near the sensor is mov ed away. It will also transmit alert signal to the control panel in case of low batter y.
External input for wired accessor y is available at the N/C interface.
The tampe r protection ensures that sabotage attempt s to mov e the contact will result in an alarm activation.
Appearance
LED indicator
LED Indication
LED flashes once: Door/window is opened and transmitter sends signal to the control panel.
Flash once per 3 seconds: Low power indication, please change batter y as soon as possible.(User will get alert SMS about the low batter y if the door contact is connected to the GSM alarm system.)
PCB Layout
Tamper switch
Zone setting
Transmitter Magnet
38
39
Installation & Notice
Remov e the batter y activation strip,the sensor will enter working state immed iately.
Mou nt the sensor on the door frame and the mag net on the door.
Mak e sure the mag net is on the right side of the transmitter
Place the transmitter in the desired location, mou nt the mag net no more than 1cm away from the transmitter and secure the transmitter and mag net with double-sided tapes or screws.
Avoid mou nting sensors in areas with a large quantity of met al or electrical wiring, such as a furnace or utility room.
Specifications
Powe r supply
DC 1.5V (AA 1.5V LR6 Batter y x 1pc)
Static current
≤ 30uA
Alarm current
≤ 40mA
Transmitting distance
≤80m (in open area)
Radio frequency
315MHz or 433MHz (±75KHz)
Housing mat erial
ABS plastic
Ope ration condition:
Tempe rature: -10°C~55°C
Relative humidity: ≤80% (non-condensing)
Transmitter dimen sions (LxWxH)
71 x 34 x 17.5mm
Mag net dimen sions (LxWxH)
51 x 12 x 13.5mm
40
41
Wireless PIR Motion Detector
Features
PIR-900 is a high performan ce wireless P.I.R. mot ion detector.
It consists of digital dual-core fuzzy logic infrared control chip and intelligent analysis which effectively identify interference signals from body mov emen t signals and reduce false alarm rate.
With automa tic tempe rature comp ensation and anti-air turbulence technology, it easily adapts to environme ntal changes.
The detector also has the advantages of energy saving, reliability and easy installation.
Appearance
1
2
1. Detection window
2. LED indicator
3. Bracket
3
LED Indication
Flash continuously: Under the self-testing state.
Flash once: Intruder is detected.
Flash twice: Self-testing is finished, enters the working mod e.
Flash once per 3 seconds: Under voltage indication, please change the batteries immed iately.(User will get alert SMS about the low batter y if the PIR detector is connected to the GSM alarm system.)
42
43
PCB Layout
LED ON / OFF Infrared sensor
Usage
Remov e the batter y activation strip to activate batteries. It will start self-testing for one minute.
Mode Setting
Tamper switch
Zone setting
Infrared sensor: It detects the infrared rays released by human body motion, please don’t touch the surface and always keep it clean.
Tamper switch: Once the case is opened in working state, the tamper switch will be triggered and then generates an alarm signal.
Test Button
Testing mod e:
Af ter self-testing, press the test button, the sensor enters testing mod e, and detects once ever y 10 seconds. Af ter 3 minutes, the
LED flashes twice, and the sensor enters the working mod e.
44
45
Working mod e:
In working state, if the sensor is triggered twice within 3 minutes, it will enter sleeping mod e to save power. Af ter no mov emen t within next 3 minutes, the sensor goes back to the working mod e.
Connect to alarm pan el:
Press the connect key on the alarm panel, and then press the test button of the sensor twice to send alarm signal. Whe n one beep is heard, they are connected.
To check if they are connected successfully, arm the system, and trigger the sensor again, if there is an alarming, the connection is successful.
Installation & Notices
Avoid mou nting the detector close to windows, air conditioner, heater, refrigerator, oven, su nshine and places where the tempe rature changes fast or the air stream flows frequently.
If two detectors are installed in the same detection scope, please adjust the location to avoid interference and false alarm.
2m
Ground
Top view Side view
46
47
Fix the bracket on the wall with screws and attach the detector to the bracket. Adjust installation height or bracket to change the detection distance and angle. It is recomme nded to mou nt it at the height of 2m from the ground.
The detector is mor e sensitive to the cross mov emen t than to the vertical mov emen t, so the performance of detector is best when the detection direction is vertical to the walking direction of people.
Testing (Walk Test)
A. Af ter installation, power on the detector. Af ter one minute
self-testing, press the test button, walk in the scope (from
left to right or from right to left) and watch the LED indicator
to mak e sure the detector is working.
B. The LED indicator flashes once when body
mov emen t is detected.
C. Adjust the detector angle accordingly to achieve the best
detection effect.
Detection Scope
110° 2m
0m 2m 4m 6m 8m
0m
Top view Side view
48
49
Specifications
Powe r supply
DC 3V (AA 1.5V LR6 Batter y x 2 pcs)
Static current
≤ 50uA
Alarm current
≤ 9.5mA
Detection scope
8m/110°
Transmitting distance
≤ 80m (in open area)
Radio frequency
315MHz or 433MHz (± 75KHz)
Housing mat erial
ABS plastic
Ope ration condition
Tempe rature: -10°C~55°C
Relative humi dity: ≤80% (non-condensing)
Detector dimen sions (L x W x H)
108 x 52 x 36.8 mm
Bracket dimen sions (L x W x H)
52 x 30 x 26.5 mm
Zone Setup for Wireless Sensors
Home Mode Zone Normal Zone Single Delay Zone
The PIR motion detector is set in Home Mode Zone in default.
It is recommended to set Door/Window Contact on entrance in Single Delay Zone.
Users should reconnect the detector with the control panel after the zone is changed.
24-H Zone
Note: In any condition, the system will alarm immediately once the detector in this zone is triggered.It is recommended to set smoke detector, gas detector and outdoor beam sensor at 24-H zone.
50
产品型号
设 计
印刷尺寸
工 艺
注:
双色、双面印刷
CG-G5
林寿
210X145mm
骑马钉56P
部件名称
材 料
说明书
80克书写纸
成品尺寸 105X145mm
版 本
PA: OI-G5-EN-1309-V2.2-UK
advertisement
Key Features
- Supports 50 wireless sensors, 50 RFID tags, and 10 remote controls
- Built-in 1,000,000 RF code combinations for high reliability
- Cellular communicator for simple operation and remote monitoring
- Built-in speaker for siren and two-way talking
- Two 800mAh lithium batteries for 5-hour standby
- SMS alerts for power failure, power recovery, and low battery
- Firewall to prevent unauthorized access
- Multiple arming and disarming options, including SMS, RFID tags, and remote controls
- Customizable zone settings for tailored protection
- Remote control and monitoring via free mobile app
Related manuals
Frequently Answers and Questions
How do I arm the system?
How do I disarm the system?
What happens if the power goes out?
Can I monitor the system remotely?
How many wireless sensors can I connect to the system?
advertisement