Chuango G5 User Manual

Add to My manuals
29 Pages

advertisement

Chuango G5 User Manual | Manualzz

Printed in Hong Kong

PA: OI-G5-EN-1309-V2.2-UK

GSM/SMS/RFID

Security Alarm System

Features

ARM + Auror CPU

Support 10 remote controls, 50 wireless sensors and 50 RFID tags

Built-in 1,000,000 RF codes combination maintains high reliability

Cellular communicator, simple operation

Store 5 phone numbers, 1 speed-dial number, and 1 RFID SMS notification number

Exit and entry delay

SMS alert for low battery of two-way accessories

Arm and disarm the system by SMS or free phone call

Remote monitoring site via phone

Firewall to prevent operation from unauthorized users

Built-in loud speaker for siren and two-way talking

Built-in two pieces of 800mAh lithium batteries enable 5-hour standby

SMS alerts for power failure, power recovery and low battery

850/900/1800/1900MHz GSM frequency, applicable for universal

Table of Contents

Included Accessories

Control Panel Layout

Record/Play Voice Memo

RFID Tag

Speed Dial

Phone Call

Recording Alarm Message

Electronic Lock Output

SMS Operation

Disarm

Arm

Stay Arm (Home Mode)

Two-Way Talk

Call-Back to Record Voice Memo

Settings Inquir y

Store Alarm Phone No.

Store Alarm SMS No.

Store SMS No. for RFID Tags

Store Speed Dial Phone Number

Change Zone Name

SMS Alert for Low Batter y of Accessories

1~2

3 ~ 5

6

8

9~29

8

8

7

7

SMS Alert for Tamper Alarm of Accessories

Change RFID Tags SMS Notice

Entr y and Exit Delay Time

Siren Volume and Ringing Time

Disarm Password

Single Zone Delay Time

Change System Language

Delete Wireless Sensors

Delete RFID Tags

Delete Remote Controls

Restore System to Default Setting

Alarm Notification Ways

Phone Remote Control Instruction

Test Mode

Arm & Disarm by Free Phone Call

Connect Wireless Accessories & RFID Tags

Connect Wireless Siren

Specifications

Wireless Remote Control

Wireless Door/Window Contact

Wireless PIR Motion Detector

Zone Setup for Wireless Sensors

32

32

33

34~36

37~40

41~49

50

30

30

31

31

Included Accessories

CG-G5 Control Panel x 1

The control panel is known as the “hear t and brain” for alarm system, which is used for receiving and processing signals from wireless sensors and remote controls. Users can make settings freely by

GSM cell phone and Apps. In case of emergency, the panel rings on site and dials the pre-stored alarm phone numbers automatically. When users pick up the phone, they are able to hear the voice recording aler t and choose to monitor on site or disarm the system.

*Input keywords “G5” in Google Play or App Store to download free App for remote controlling and setting the alarm system anytime and anywhere.

Wireless PIR Motion Detector x 1

The wireless PIR Motion Detector is an intelligent passive infrared motion sensor, designed to detect human movements within an approximate range of 6 to 8 meters from the detector. The detector includes fuzzy logic to minimize false alarms from unwanted heat sources. With power saving feature, the detector will enter sleeping mode after the second activation within 3 minutes to save power.

TAG-26 RFID Tag x 2

The RFID tag is for disarming

The system and unlocking the electronic door lock (if connected).

AC Adapter x 1

Supply power to the control panel. In case of power failure, two built-in backup batteries in the panel will support 5-hour standby.

Brackets (wall-mounted and desktop) for control panel x 2

Bracket for PIR Motion

Detector x 1

Screws and wall plugs x 4

1

Wireless Door/Window Contact x 1

The Door/window contact can be installed on doors, windows and any other objects that open and close.

The sensor transmits signals to the control panel when a magnet mounted near the sensor is moved away.

Wireless Remote Control x 2

The remote control is compact and portable; it is convenient to carry it to arm, disarm, part arm the alarm system and also make an emergency call.

Double-sided tape for

Door/Window Contact x 1

User Manual x 1

2

Control Panel Layout

GSM Signal Indicator

GSM network searching: Flashes once every second

GSM signal in normal: Flashes once every two seconds

Touch Keypad

Status Indicator

3

Arm

Disarm

Call

RFID Reader / Play Voice Memo

Stay Arm (Home Mode)

Record Voice Memo /

Connect Button

Arm

Press to arm the system.

Home mode

Press to arm the sytem in home mode.

All the sensors in Normal Zone are armed except those in

Home Mode Zone which are disarmed so that user can move freely at home.

Disarm on keypad:

Input 4 digits password (default:1234) , and press to disarm the system after one beep.

If three beeps are heard, password is wrong and please input again.

Disarm by RFID tag:

Induce the RFID tag to the RFID Reader area to disarm the system.

4

Rear Side

MIC Buzzer Tamper Switch Loudspeaker

Record / Play Voice Memo

Press for 2 seconds to record 10 seconds voice messages.

Or send SMS to system for calling back to record the voice messages. The Play Voice Memo Button will be flashing in green to remind you. Users can touch the center of circle to listen to the voice memo. The LED indicator blacks out when the voice memo is played. Replay by touching it again.

5

SIM Card Slot

Back-up Batteries

Input for Wired Sensors

(24-hour zone)

Input for Wired Sensors

(normal zone)

Output for

Electronic Lock

Output for Wired Siren

≤ 500mA

Adapter Interface

Power On/Off

6

RFID Tag

The RFID tag is for disarming the system and unlocking the electronic door lock (if connected).

You can rename the RFID tags and store a mobile phone number to send SMS notice when family members come home and disarm the system.

Nancy

Nancy came home

7

Mom

Administrator

Note!

Only after SMS No. is stored, and the RFID tags SMS notice is changed (4 RFID tags can be renamed), users can receive notice SMS once someone disarms the system by RFID tag.

Speed Dial

Press Call Button , the panel auto dials to pre-stored phone number of the host, the LED blacks out after talk.

User can also press Call Button to end talk.

Phone Call

Dial phone number and then press Call Button to start talk, the LED blacks out after talk.

User can also press Call Button to end talk.

Recording Alarm Message

Make sure the panel is in home mode. Input passcode, and then press the button and button on the panel, the LED light of button is on, the panel starts 10 seconds recording of the alarm message.

When the alarm message is recorded, user will firstly hear the alarm message when picking up the phone call from the panel. Then, user can start remote control the control panel.

See detailed instruction in Page 30.

Electronic Lock Output

When system is disarmed, the output signal opens electronic lock automatically.

8

9

SMS Operation

Insert a SIM card to the control panel, then send a text of “?” to the SIM card number, the operation guide message will be replied.

You can control the alarm system by following the guide message:

Send:

?

System replies first grade guide menu:

‘0’ Disarm

‘1’ Arm

‘2’ Home mode

‘3’ Two-way talk

‘4’ Call-back voice memo

‘00’ Settings inquiry

‘??’ Store phone and SMS No.

Send:

??

System replies second grade guide menu:

‘5’ Store alarm phone No.

‘6’ Store alarm SMS No.

‘7’ Store SMS No. for RFID tags

‘8’ Store speed dial phone No.

‘???’ System setups

Send:

???

System replies third grade guide menu:

‘91~99’ Zone name

‘10’ RFID tags SMS notice

‘11’ Entry and exit delay time

‘12’ Siren volume and ringing time

‘13’ Disarm password

‘14’ Single zone delay time

10

11

Disarm

Send:

0

System disarmed.

Arm

Send:

1

System armed.

Stay Arm (Home Mode)

Send:

2

System in home mode.

12

Two-Way Talk

Send:

3

Send ‘3’ to the SIM card number, the alarm will call back.

Pick up the phone and start two-way talk.

Call-Back to Record Voice Memo

Send:

4

13

Send ‘4’ to the SIM card number, the alarm will call back.

Pick up the phone, and leave 10 seconds message.

The panel will hang up after 10 seconds.

Settings Inquiry

Send:

00

System status

Entry and exit delay time: 0sec

Single zone delay time: 30sec

Siren volume: 2

Siren ringing time: 5min

Disarm password: 1234

Note:

Value of default setting will be changed once users finish programming.

14

Store Alarm Phone No.

Send:

5

TEL:

1.

2.

3.

4.

5.

15

For ward > Edit

TEL:

1. 67890033

2. 67890022

3. 67890011

4. 67890000

5.

Store alarm phone No.

successfully.

Special Tips:

Firewall feature is adopted to prevent nonstored phone no. and SMS no. to remote control the system and change settings.

Store Alarm SMS No.

Send:

6

SMS:

1.

2.

3.

4.

5.

For ward > Edit

SMS:

1. 67890033

2. 67890022

3. 67890011

4. 67890000

5.

Store alarm SMS No. successfully.

Special Tips:

Please edit on the basis of the replied text and don't change the format. Other wise, the system will not recognize the command.

16

Store SMS No. for RFID Tags

Send:

7

SMS No. for RFID tags

(0-20 digits):

1.

For ward > Edit

SMS No. for RFID tags

(0-20 digits):

1. 67890033

Store SMS No. for RFID tags successfully.

17

Note: Only after SMS No. is stored, and the RFID tags

SMS notice is changed, users can receive notice SMS once someone disarms the system by RFID tag.

Store Speed Dial Phone Number

Send:

8

Speed dial phone number

(0-20 digits):

1.

For ward > Edit

Speed dial phone number

(0-20 digits):

1. 67890033

Store speed dial phone number successfully.

18

19

Change Zone Name

Special Tips!

th

30 English characters at most for each line due to SMS character limit.

Other alarm zones are fixed as Zone 10 alarm, Zone 11 alarm and so on.

Send: 91~99

9 1

Zone1 name: Zone 1 alarm

For ward > Edit

Zone1 name: Entrance door sensor

Change zone name successfully.

SMS Alert for Low Battery of Accessories

(available for two-way accessories such as DWC-102 and PIR-900/910)

SMS will be sent for 1-9 zones with its zone name as

“Zone name + low battery”.

Bedroom PIR low battery.

SMS alert for 10~50 zones will be “Zone number + low battery”.

Zone 10 low battery.

SMS Alert for Tamper Alarm of Accessories

(available for two-way accessories such as DWC-102 and PIR-900/910)

SMS will be sent for 1-9 zones with its zone name as

“Zone name + tamper alarm”.

Bedroom PIR tamper alarm.

SMS alert for 10~50 zones will be “Zone number + tamper alarm”.

Zone 10 tamper alarm.

20

Change RFID Tags SMS Notice

Send:

10

Change RFID tags SMS notice:

1.

2.

3.

4.

21

For ward > Edit

Change RFID tags SMS notice successfully.

Change RFID tags SMS notice:

1. Tom

2. Nurse

3. Nancy

4. David

Note:

Only after SMS No. is stored, and the RFID tags SMS notice is changed, users can receive notice

SMS once someone disarms the system by RFID tag.

Entry and Exit Delay Time

Send:

11

Entry and exit delay time

(0-300 sec.):

0

For ward > Edit

Entry and exit delay time

(0-300 sec.):

10

Set delay time successfully.

Notice!

If users don’t want to take remote control or RFID cards with them, this function can be used. Once the delay time is set, when you arm the system, one beep will be heard every second to remind the user to leave.

The reminding rhythm will be speeded up in the last 15 seconds.

Once the intruder is detected, the alarm will be delayed accordingly.

22

23

Siren Volume and Ringing Time

Send:

12

Siren volume(0 Mute,

1 Low, 2 High):

2

Siren ringing time(1-9min):

5

For ward > Edit

Siren volume(0 Mute,

1 Low, 2 High):

1

Siren ringing time(1-9min):

3

Set siren volume and ringing time successfully.

Disarm Password

Send:

13

Disarm password(4-6 digits):

1234

For ward > Edit

Disarm password(4-6 digits):

8888

Set disarm password successfully.

24

25

Single Zone Delay Time

Send:

14

Single zone delay time (0-300 sec.):

30

For ward > Edit

Single zone delay time (0-300 sec.):

15

Set single zone delay time successfully.

Change System Language

Send: 0086 to change language to be Chinese

0086

中文语言修改成功!

Send: 0001 to change language to be English

0001

Set English successfully.

26

27

Delete Wireless Sensors

Send:

21

Delete wireless sensors successfully.

Delete RFID Tags

Send:

22

Delete RFID tags successfully.

Delete Remote Controls

Send:

23

Delete remote controls successfully.

Note:

Press Tamper Switch 3 times within 3 seconds, all wireless sensors,

RFID tags, and remote controls will be deleted after two beeps.

28

29

Restore System to Default Setting

Send:

0000

System has been restored to factory settings.

Or press Tamper Switch 5 times within 3 seconds, the system will be restored to factor y settings after two beeps.

Note:

After programming, only stored numbers can send SMS to restore the system.

Alarm Notification Ways

Once the alarm system is triggered , the control panel will send SMS in turns , and then will make calls in turns . The first round of dialing , each stored phone number will get the phone call . From the second round , as long as one user picks up the phone , the control panel will stop dialing to next number .

Phone Remote Control Instruction

User can control the alarm system by phone only when receiving an alarm call for an emergency event.

Operation

Press 1

Press 0

Press 9

Press 6

Press

Press #

Function

Arm the system

Disarm the system

Turn on siren

Turn off siren

Two-way talk

Re-play recorded alarm voice message

Illustration

Deter the intruder

If it is not heard clearly

30

31

Test Mode

Press the Disarm button on the panel for 3 times, the system enters Test Mode for 10 minutes after a long beep.

During this period, the panel will not alarm but give out three beeps when the tamper switch or the sensors connected are triggered.

Press the Arm button on the panel to exit Test Mode.

Arm & Disarm by Free Phone Call

Arm

Call the control panel number, hang up when hearing the ring tone. The panel will call back. The user hangs up the phone directly to arm the system.

Disarm

Call the control panel number, hold on until the panel hangs up the call. The panel will not call back. System is disarmed.

Connect Wireless Accessories & RFID Tags

Input 4-6 digits password, press Connect Button , the LED indicator lights up, then trigger the accessory or RFID tag once within 15 seconds, the connection is successful after a beep.

Once two beeps are heard, the accessory has been connected before. The first connected accessory is in Zone 1, the second one in Zone 2, and so on.

Connect Wireless Siren

The newly-added wireless siren can be used after connecting to the control panel.

Operation:

Press the Connect Button of the wireless siren for 0.5 second, the Connect Button LED indicator lights on, and then press the

Arm Button on the control panel, the siren will be connected after one beep is heard.

Testing: Press the Arm Button on the remote control, to make sure that the internal siren and wireless siren both beep once, the connection is successful. If not, the connection fails, please reconnect them.

Once the intruder is detected, both internal siren and wireless siren will hoot to deter the illegal intruder. (The siren will be off in 5 minutes as the default setting). At the same time, the alarm system will send SMS and auto dial to users.

32

33

Specifications

Product name : GSM/SMS/RFID Security Alarm System

Model No. : CG-G5

Control panel’s power supply :

Input: AC 110-240V, 50/60Hz

Output: DC 12V 500mA

GSM working frequency : 850/900/1800/1900MHz

Standby current : 110mA

Alarm current : 340mA

Internal battery backup :

Lithium Battery : 3.7V 800mAh x 2 PCS (BL-5B)

Internal siren : 95dB

Allowed amount of expandable wireless accessories :

10pcs remote controls, 50pcs wireless sensors and 50pcs RFID tags.

Radio frequency : 315MHz or 433MHz (±75KHz)

Housing material : ABS plastic

Operation condition:

Temperature: -10ºC~55 ºC

Humidity: ≤ 80% RH (non-condensing)

Size (L x W x H) : Panel : 188×132×26mm

Wireless Remote Control

Arm

Arm

Stay

LED Indicator

Disarm

Panic

Press {Arm } to arm the alarm panel and the LED indicator lights on (siren hoots once), the system enters Arm state.

If there comes an intruder, the siren will hoot to deter the intruder.

(The siren turns off after ringing for 5 minutes as default setting.)

At the same time, the system dials the pre-stored phone numbers automatically.

34

Disarm Mute Mode

Press {Disarm } to disarm the alarm panel and the LED indicator blacks out (siren hoots twice), the system is disarmed.

When intruders are detected, siren will keep hooting. Press

{Disarm } to stop siren hooting.

Home Mode

Press {Stay } button on the remote control, then press button, the siren keeps silent to finish the operation. The system is armed or disarmed in mute without disturbing other people.

Emergency Call

35

Press {Stay } button on the remote control, the system state

LED is on. All the sensors in Normal Zone are armed except the motion detector in Home Mode Zone which is disarmed so that user can move freely at home.

No matter what state the control panel is in, once SOS button on the remote control is pressed, the system immediately goes into emergent alarming state.

36

37

Wireless Door/Window Contact

Features

The DWC- 102 is a Door/Window Contact (Two-way) that can be installed on doors, windows, and any other objects that open and close. The sensor transmits signals to the control panel when a mag net mou nted near the sensor is mov ed away. It will also transmit alert signal to the control panel in case of low batter y.

External input for wired accessor y is available at the N/C interface.

The tampe r protection ensures that sabotage attempt s to mov e the contact will result in an alarm activation.

Appearance

LED indicator

LED Indication

LED flashes once: Door/window is opened and transmitter sends signal to the control panel.

Flash once per 3 seconds: Low power indication, please change batter y as soon as possible.(User will get alert SMS about the low batter y if the door contact is connected to the GSM alarm system.)

PCB Layout

Tamper switch

Zone setting

Transmitter Magnet

38

39

Installation & Notice

Remov e the batter y activation strip,the sensor will enter working state immed iately.

Mou nt the sensor on the door frame and the mag net on the door.

Mak e sure the mag net is on the right side of the transmitter

Place the transmitter in the desired location, mou nt the mag net no more than 1cm away from the transmitter and secure the transmitter and mag net with double-sided tapes or screws.

Avoid mou nting sensors in areas with a large quantity of met al or electrical wiring, such as a furnace or utility room.

Specifications

Powe r supply

DC 1.5V (AA 1.5V LR6 Batter y x 1pc)

Static current

≤ 30uA

Alarm current

≤ 40mA

Transmitting distance

≤80m (in open area)

Radio frequency

315MHz or 433MHz (±75KHz)

Housing mat erial

ABS plastic

Ope ration condition:

Tempe rature: -10°C~55°C

Relative humidity: ≤80% (non-condensing)

Transmitter dimen sions (LxWxH)

71 x 34 x 17.5mm

Mag net dimen sions (LxWxH)

51 x 12 x 13.5mm

40

41

Wireless PIR Motion Detector

Features

PIR-900 is a high performan ce wireless P.I.R. mot ion detector.

It consists of digital dual-core fuzzy logic infrared control chip and intelligent analysis which effectively identify interference signals from body mov emen t signals and reduce false alarm rate.

With automa tic tempe rature comp ensation and anti-air turbulence technology, it easily adapts to environme ntal changes.

The detector also has the advantages of energy saving, reliability and easy installation.

Appearance

1

2

1. Detection window

2. LED indicator

3. Bracket

3

LED Indication

Flash continuously: Under the self-testing state.

Flash once: Intruder is detected.

Flash twice: Self-testing is finished, enters the working mod e.

Flash once per 3 seconds: Under voltage indication, please change the batteries immed iately.(User will get alert SMS about the low batter y if the PIR detector is connected to the GSM alarm system.)

42

43

PCB Layout

LED ON / OFF Infrared sensor

Usage

Remov e the batter y activation strip to activate batteries. It will start self-testing for one minute.

Mode Setting

Tamper switch

Zone setting

Infrared sensor: It detects the infrared rays released by human body motion, please don’t touch the surface and always keep it clean.

Tamper switch: Once the case is opened in working state, the tamper switch will be triggered and then generates an alarm signal.

Test Button

Testing mod e:

Af ter self-testing, press the test button, the sensor enters testing mod e, and detects once ever y 10 seconds. Af ter 3 minutes, the

LED flashes twice, and the sensor enters the working mod e.

44

45

Working mod e:

In working state, if the sensor is triggered twice within 3 minutes, it will enter sleeping mod e to save power. Af ter no mov emen t within next 3 minutes, the sensor goes back to the working mod e.

Connect to alarm pan el:

Press the connect key on the alarm panel, and then press the test button of the sensor twice to send alarm signal. Whe n one beep is heard, they are connected.

To check if they are connected successfully, arm the system, and trigger the sensor again, if there is an alarming, the connection is successful.

Installation & Notices

Avoid mou nting the detector close to windows, air conditioner, heater, refrigerator, oven, su nshine and places where the tempe rature changes fast or the air stream flows frequently.

If two detectors are installed in the same detection scope, please adjust the location to avoid interference and false alarm.

2m

Ground

Top view Side view

46

47

Fix the bracket on the wall with screws and attach the detector to the bracket. Adjust installation height or bracket to change the detection distance and angle. It is recomme nded to mou nt it at the height of 2m from the ground.

The detector is mor e sensitive to the cross mov emen t than to the vertical mov emen t, so the performance of detector is best when the detection direction is vertical to the walking direction of people.

Testing (Walk Test)

A. Af ter installation, power on the detector. Af ter one minute

self-testing, press the test button, walk in the scope (from

left to right or from right to left) and watch the LED indicator

to mak e sure the detector is working.

B. The LED indicator flashes once when body

mov emen t is detected.

C. Adjust the detector angle accordingly to achieve the best

detection effect.

Detection Scope

110° 2m

0m 2m 4m 6m 8m

0m

Top view Side view

48

49

Specifications

Powe r supply

DC 3V (AA 1.5V LR6 Batter y x 2 pcs)

Static current

≤ 50uA

Alarm current

≤ 9.5mA

Detection scope

8m/110°

Transmitting distance

≤ 80m (in open area)

Radio frequency

315MHz or 433MHz (± 75KHz)

Housing mat erial

ABS plastic

Ope ration condition

Tempe rature: -10°C~55°C

Relative humi dity: ≤80% (non-condensing)

Detector dimen sions (L x W x H)

108 x 52 x 36.8 mm

Bracket dimen sions (L x W x H)

52 x 30 x 26.5 mm

Zone Setup for Wireless Sensors

Home Mode Zone Normal Zone Single Delay Zone

The PIR motion detector is set in Home Mode Zone in default.

It is recommended to set Door/Window Contact on entrance in Single Delay Zone.

Users should reconnect the detector with the control panel after the zone is changed.

24-H Zone

Note: In any condition, the system will alarm immediately once the detector in this zone is triggered.It is recommended to set smoke detector, gas detector and outdoor beam sensor at 24-H zone.

50

产品型号

设 计

印刷尺寸

工 艺

注:

双色、双面印刷

CG-G5

林寿

210X145mm

骑马钉56P

部件名称

材 料

说明书

80克书写纸

成品尺寸 105X145mm

版 本

PA: OI-G5-EN-1309-V2.2-UK

advertisement

Key Features

  • Supports 50 wireless sensors, 50 RFID tags, and 10 remote controls
  • Built-in 1,000,000 RF code combinations for high reliability
  • Cellular communicator for simple operation and remote monitoring
  • Built-in speaker for siren and two-way talking
  • Two 800mAh lithium batteries for 5-hour standby
  • SMS alerts for power failure, power recovery, and low battery
  • Firewall to prevent unauthorized access
  • Multiple arming and disarming options, including SMS, RFID tags, and remote controls
  • Customizable zone settings for tailored protection
  • Remote control and monitoring via free mobile app

Related manuals

Frequently Answers and Questions

How do I arm the system?
You can arm the system by pressing the 'Arm' button on the control panel, sending an SMS command, or using the remote control.
How do I disarm the system?
You can disarm the system by entering the password on the keypad, using an RFID tag, or sending an SMS command.
What happens if the power goes out?
The system has two built-in backup batteries that will provide 5 hours of standby power.
Can I monitor the system remotely?
Yes, you can monitor the system remotely via the free mobile app.
How many wireless sensors can I connect to the system?
You can connect up to 50 wireless sensors to the system.

advertisement