American Standard 3695.001.020 Priolo 1.1-1.6 gpf ADA EverClean Universal Flushometer Toilet Spec Sheet
Add to my manuals
2 Pages
advertisement
Priolo
®
FloWise
®
16-1/2" Height
Elongated Flushometer Toilet
VITREOUS CHINA with EVERCLEAN ®
BARRIER FREE
Priolo ® FloWise ® 16-1/2" Height
Elongated Flushometer Toilet with EverClean ®
• Floor mount elongated rear outlet flushometer
valve toilet
• Vitreous china
• High Efficiency, Low Consumption. Operates in
the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf)
• Meets definition of HET (High Efficiency Toilet)
when used with a high efficiency flush valve
(1.28 gpf or 1.6 / 1.1 gpf dual flush)
• Permanent EverClean ® surface inhibits the growth of stain- and odor-causing bacteria, mold, and mildew on the surface
• 16-1/2" rim height for accessible application
• Condensation channel
• Powerful direct-fed siphon jet action
• Fully glazed 2-1/8" trapway
• 1-1/2" inlet spud
• 4 bolt caps
❏ 3695.001
Elongated bowl only, top spud
❏ 3696.001
Elongated bowl only, top spud with slotted rim for bedpan holding
❏ 3697.001
Elongated bowl only, back spud
System MaP* Score:
• 1,000 grams of miso @ 1.6 gpf or 1.28 gpf when used with an American Standard flush valve
* Maximum Performance (MaP) testing performed by IAPMO
R&T Lab. MaP Report conducted by Veritec Consulting, Inc. and Koeller and Company.
Component Parts:
❏ 047007-0070A Inlet spud (furnished with bowl)
❏ 481310.0200A
Bolt caps with retainers
(furnished with bowl)
Nominal Dimensions:
752 x 356 x 419mm
(29-5/8" x 14" x 16-1/2")
Recommended working pressure–between
25 psi at valve when flushing and 80 psi static
Fixture only, less seat and flushometer valve
Compliance Certifications -
Meets or Exceeds the Following Specifications:
• ASME A112.19.2 /CSA B45.1 for Vitreous
China Fixtures
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
To Be Specified:
❏ Color: ❏ White
❏ Seat:
❏ American Standard #5901.110 Heavy duty open
front less cover with EverClean ® surface
❏ American Standard #5905.110 Extra heavy duty
open front less cover with EverClean ® surface
❏ Alternative Seat:
❏ Flushometer Valve:
❏ 1.6 gpf:
❏ Sensor-Operated: American Standard Selectronic
DC Power #6065.161.002 (Top Spud)
❏ Manual: American Standard #6047.161.002
®
❏ Sensor-Operated: American Standard Selectronic ®
AC Power #6067.262.002 (Back Spud)
(Top Spud)
❏ 1.28 gpf:
❏ Sensor-Operated: American Standard Selectronic
DC Power #6065.121.002 (Top Spud)
®
❏ Sensor-Operated: American Standard Selectronic ®
AC Power #6067.222.002 (Back Spud)
❏ Manual: American Standard #6047.121.002
(Top Spud)
❏ 1.6 / 1.1 gpf Dual Flush:
❏ Sensor-Operated: American Standard Selectronic ®
DC Power #6065.761.002 (Top Spud)
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES - CHECK LOCAL CODES.
When installed so top of seat is 432 to 483mm (17" to 19") from the finished floor.
M117
When used with
1.28 gpf toilet flush valves
ADA
COMPLIANT
EVERCLEAN WATER
EFFICIENT
© 2018 AS America Inc.
spec_3695.001_Priolo FW 16.5Height-EL-Flushometer 11/18
3695.001/3696.001
Priolo
®
FloWise
®
16-1/2" Height
Elongated Flushometer Toilet
VITREOUS CHINA with EVERCLEAN ®
BARRIER FREE
FINISHED WALL
136mm
(5-3/8")
60mm
(2-3/8")
752mm
(29-5/8")
470mm
(18-1/2")
C/L OF SEAT POST HOLES
140mm (5-1/2") CENTERS
1" N.P.T. OR 1" C.W.T. SUPPLY
TO FLUSH VALVE
(SUGGESTED)
121mm
(4-3/4")
356mm
(14")
1 -1/2"
SPUD
711mm
(28")
13mm
(1/2")
419mm
(16-1/2")
13mm x 25mm slots
(1/2" x 1")
217mm
(8-1/2")
102mm
(4 ")
102mm
(4")
C/L OF
WASTE
OUTLET
345mm
(13-5/8")
646mm
(25-3/8")
C/L OF 1/2"
DIA. HOLES
FINISHED
FLOOR
152mm
(6")
240mm
(9-1/2")
DIMENSIONS (Nominal) NOTE: Distance from floor to closet flange centerline (rough-in) must be 4" (102 mm) with flange surface flush to 1/16" (1.6mm) max. beyond finished wall.
3697.001
FINISHED WALL
112mm
(4-3/8 ")
752mm
(29-5/8 ")
470mm
(18-1/2")
C/L OF SEAT POST HOLES
140mm (5-1/2") CENTERS
356mm
(14")
13mm
(1/2")
438mm
(17-1/4")
419mm
(16-1/2")
13mm x 25mm slots
(1/2 " x 1")
217mm
(8-1/2")
102mm
(4 ")
102mm
(4")
C/L OF
WASTE
OUTLET
345mm
(13-5/8")
646mm
(25-3/8")
C/L OF 1/2”
DIA. HOLES
FINISHED
FLOOR 240mm
(9-1/2")
152mm
(6")
DIMENSIONS (Nominal) NOTE: Distance from floor to closet flange centerline (rough-in) must be 4" (102 mm) with flange surface flush to 1/16" (1.6mm) max. beyond finished wall.
NOTES:
PRODUCTS 3695 SHOWN, 3696 SAME AS EXCEPT WITH SLOTTED RIM
FOR BED PAN HOLDING.
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM
BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST
VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING.
FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE
ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR
12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED.
REFER TO VALVE MANUFACTURER AND LOCAL CODES.
IMPORTANT : Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.
M118
© 2018 AS America Inc.
spec_3695.001_Priolo FW 16.5Height-EL-Flushometer 11/18