Hyon HR1900P Installation And Operational Manual

Add to My manuals
12 Pages

advertisement

Hyon HR1900P Installation And Operational Manual | Manualzz

RF Repeater

Installation and Operational Manual

(Model: HR1900P)

J AS

Teletech

Home Repeater JAS Teletech

Table of Contents

1. General Information

1.1 Introduction

1.2 Specifications

1.3 Description

2. Installation

2.1 Introduction

2.2 Unpacking and Inspection

2.3 Preparation for Use

2.4 Before Installation

2.5 Antenna Installation

2.6 Repeater Installation

2.7 Connectors

2.8 Installation Example

3. Operation

3.1 Introduction

3.2 Operating Instructions

4. Trouble Shooting

5. Drawings

Home Repeater JAS Teletech

1. General Information

1.1 Introduction

This manual provides information pertaining to the installation and operation of JAS

Teletech’s HR1900P Home Repeater. This Unit is for CDMS, GSM, and TDMA modulations in the PCS frequencies as shown in Table 1-1.

<Tebla 1-1: HR1900P>

Model Number

Down Link*

Frequencies

Up Link**

Frequencies

Modulation

CDMA, TDMA

* Down Link: signal from base station to mobile

** Up lInk: signal from mobile to base station

Home Repeater JAS Teletech

1.2 Specifications

No

.

Parameters

1 Frequency Range

2 Output Power

<Table 1-2: HR1900P Specifications>

Specifications

Downlink Uplink

Remarks

1930~1990MHz 1850~1910MHz 60MHz

+7dBm /1FA[Max.]

Fc +885KHz

Fc -885KHz

5

In Band

Spurious

Fc +1.98MHz

6

Fc -1.98MHz

Out OF

Band

Spurious

Less than

-13dBm/1MHz

7 P1dB

9

Down/Up Link shutdown Function

11 V.S.W.R

12 Impedance

13 Operating Temperature

14 Dimension (W x H x D)

15 Weight

16 RF Connector

≤ 7dB

≥ -45dBc/30KHz

≥ -45dBc/30KHz

≥ -50dBc/30KHz

≥ -50dBc/30KHz

≥ -13dBm

≥ +14dBm

≥ +24dBm

≥ 9dBm

≤ 7dB

≤ 1 : 2.0

50 Ω

0 ~ +50 ℃

120mm x 97mm x 43mm [Max.]

≤ 600 g

SMA-Type (Female)

@ Full Band

Up/Down Link Port

Without Connector

Up/Down Link Port

Home Repeater JAS Teletech

1.3 Description

This product is designed to cover blank spots of small offices, hotel rooms, small parking lots, garages or small buildings. It helps to improve PCS communications signal and coverage by extending the coverage of a base station.

Outdoor antenna receives signal from a PCS base station, then HR1900P repeater amplifies the signal. After amplification, the signal is passed through to the indoor antennas. Conversely, signals from handsets are amplified and retransmitted to the base station.

2. Installation

2.1 Introduction

This section provides information for the installation and setup of the HR1900P repeater. The information consists of procedures for unpacking, inspection and preparation for the installation, as well as the actual installation and the setup.

2.2 Unpacking and Inspection

Examine the shipping carton for damage before unpacking the unit. If the shipping carton is damaged, try to have the carrier’s agent present when the equipment is unpacked. If visual inspection reveals physical damage to the equipment, you should send it back for replacement.

Verify that the equipment is complete, as listed under packing slip. Contact JAS

Teletech with any missing component.

2.3 Preparation for Use

The power supply of the HR1900P accepts 5.1 VDC. Power consumption of the

HR1900P is approximately 2.5 Watts.

The HR1900P is intended for indoor use only. Do not install it where it might be exposed to the outside elements as this could result in destruction of the unit and other hazards. For normal operations, the environmental conditions should be as follow.

Temperature range: -20 ℃ ,to 50 ℃

Home Repeater JAS Teletech

Maximum Humidity: 95%

You will need to determine the following before beginning the HR1900P installation: a. Base Station location b. Location where the outdoor antenna is to be installed c. Location where the indoor antenna is to be installed d. Location where the HR1900P is to be installed e. Length and type of coaxial cable needed to connect from the outdoor antenna to the repeater unit f. Length and type of coaxial cable needed to connect from the repeater unit to the indoor antenna

Select a site for your outdoor antenna, making sure you have enough signal strength at that location. Using coax cable, connect the antenna to the repeater. If you are using directional antenna such as a Yagi type, the antenna should be installed so that it is in line of sight of the base station. Then, align the directional antenna toward that direction, and secure the antenna using provided mounting hardware.

Use of a lightning arrester is highly recommended. By installing a lightning arrester between the outside antenna and the repeater, you can protect the repeater unit from electrical surge from lightning.

Install the indoor antenna at a convenient location. It should be free of metallic obstruction in order to have an effective coverage. Depending on the circumstance of the installation, either one or a combination of following antenna can be used: Ceiling mount patch antenna, Wall mount patch antenna, Corner reflector

HR1900P is an indoor repeater. Accordingly, the environment of the intended installation site needs to be considered. The repeater must be shielded from moisture, such as rain, and excessive temperatures. The operating temperatures should be between -20 ℃ and 50 ℃ .

Home Repeater JAS Teletech

Verify all RF connectors are tightened and cables and antennas are secured. Connect

AC/DC Adaptor on the repeater’s DC IN connector. The Power indicator LED should be green. Make sure that no other LED is illuminated. If any other LED is lit, consult the trouble shooting page of this manual, or “2.6.2 Antenna Isolation and Alignment” section.

2.6.2 Antenna Isolation and Alignment

HR1900P is equipped with an over drive protection circuit. If the output power level of uplink exceeds prescribed limit, then uplink is disconnected and the FAIL LED(RED) is on. Repeater automatically checks output power level every 1 minute of a 5 minute cycle when uplink has over power. If uplink still exceeds level then shut down mode continues for another 10 minutes. After 10 minutes, uplink is switched on again and it checks output power again.

A. Antenna

If you are triggering the overdrive alarms at any point, try to increase the isolation between the antennas by relocating them. The indoor antenna should be placed physically as far away from the outdoor antenna as practical. If the geometry of the intended coverage area allows it, you should also try the indoor antenna in such way that interference between the antennas is at the minimum. If you are using directional antennas, try to find a location for the indoor antenna where it can cover the needed area and oriented back o back with respect to the outdoor antenna.

2.7 Connectors

Figure 2-7 shows the connectors and Table 2-7 provides a description of each connector on the HR1900P unit.

<Table 2-7: HR1900P Connectors>

Label Description

DD IN

TO BASE

Connect AC/DC Adaptor for supplying DC power to the unit

SMA-type female connector transmits base station RF, receives mobile RF, and connects to the outdoor antenna

Home Repeater JAS Teletech

SMA-type female connector transmit mobile RF, receives base station RF, and connects to the indoor antenna

To Mobile

<Figure 2-7: HR1900P Connectors>

HR1900P can be installed as shown in Figure 2-8.

To Base

Home Repeater JAS Teletech

3. Operation

3.1 Introduction

This section provides information for operating the HR1900P repeater.

3.2.1 Power-up

Connect the repeater to AC/DC Adaptor. If no FAIL condition is present, only the

“POWER” LED will remain lit. The repeater is then operating properly.

3.2.2.1 Overdrive Fail

There is one overdrive fail on the unit, for the uplink. Over driving occurs when the RF output power of the repeater exceeds a prescribed limit. This means that the input RF power level is too high, or the repeater is oscillating. The condition may be transient, caused by a passing emergency vehicle emitting a strong signal for example, or permanent, due to a nearby base station. It may also indicate low isolation between the antennas, which causes the unit to oscillate (please refer to the section 2.6.2 of this manual for antenna alignment and isolation.)

The overdrive fail on the HR1900P repeater is design to detect whether the over driving is transient or permanent. If the output power level of uplink exceeds prescribed limit ,then uplink is disconnected and the FAIL LED(RED) is on. Repeater automatically checks output power level every 1 minute of a 5 minutes cycle when uplink has over power. If uplink still exceeds level then shut down mode continues for another 10 minutes. After 10 minutes, uplink is switched on again and it checks output power level again. (Repeaters the process)

4. Trouble Shooting

If the repeater does not operate properly after installation, first make sure that the installation procedures as described in section 2 of this manual were followed correctly.

Inspect each connection, both RF and AC, and connectors for a secure fit, checking to see if all the connections are made to the proper ports of the unit and the antennas.

If the malfunction is due to an alarm condition, refer to the appropriate part of the section 3.2 of this manual. Corrective actions may be taken for the overdrive alarms.

Home Repeater JAS Teletech

CAUTION!

There are no user serviceable parts in the HR1900P.

DO NOT OPEN the unit. There is a danger of an electric shock.

Opening the covers of the unit will void all warranties.

Home Repeater JAS Teletech

5. Drawings

5.1 Front and Back views

<Figure 5-1: HR1900P Front view>

5.2 Top and Bottom views

Top

Home Repeater JAS Teletech

Bottom

Home Repeater JAS Teletech

advertisement

Related manuals

advertisement