advertisement
M10i Multiservice Edge Router Interface Module
Reference
Modified: 2018-07-08
Copyright © 2018, Juniper Networks, Inc.
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000 www.juniper.net
Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc. and/or its affiliates in the United States and other countries. All other trademarks may be property of their respective owners.
Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
M10i Multiservice Edge Router Interface Module Reference
Copyright © 2018 Juniper Networks, Inc. All rights reserved.
The information in this document is current as of the date on the title page.
YEAR 2000 NOTICE
Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.
END USER LICENSE AGREEMENT
The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://www.juniper.net/support/eula/ . By downloading, installing or using such software, you agree to the terms and conditions of that
EULA.
ii Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Determining Transceiver Support and Specifications for M Series and T Series
Fast Ethernet 100BASE-FX Optical Interface Specifications . . . . . . . . . . . . . . . . . 13
SONET/SDH OC3/STM1 Optical Interface Specifications . . . . . . . . . . . . . . . . . . . 14
SONET/SDH OC3/STM1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications . . . . . . . . 15
SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications . . . . . . . . . . . . . . 15
SONET/SDH OC12/STM4 Optical Interface Specifications . . . . . . . . . . . . . . . . . . 16
SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications . . . . . . . . . . . . 16
SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications . . . . . . . 16
SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications . . . . . . . . . . . . . 17
SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications . . . . . . . . . . . . . 17
SONET/SDH OC48/STM16 Optical Interface Specifications . . . . . . . . . . . . . . . . . 18
SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications . . . . . . . . . . . 18
SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications . . . . . . 18
SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications . . . . . . . . . . . . 19
SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications . . . . . . . . . . . 19
Copyright © 2018, Juniper Networks, Inc.
iii
M10i Multiservice Edge Router Interface Module Reference iv
Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . 33
Channelized DS3 and E3 Enhanced IQ (IQE) PIC (M10i Router) . . . . . . . . . . . . . . 33
Channelized E1/T1 Enhanced IQ (IQE) PIC (M10i Router) . . . . . . . . . . . . . . . . . . . 36
Channelized OC3/STM1 Enhanced IQ (IQE) with SFP (M10i Router) . . . . . . . . . . 38
Channelized OC12/STM4 Enhanced IQ (IQE) PIC with SFP (M10i Router) . . . . . . 43
Channelized OC3/STM1 Circuit Emulation PIC with SFP (M10I Router) . . . . . . . . 49
Ethernet Enhanced IQ2 (IQ2E) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . . 67
Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (M10i Router) . . . . . . . . . . . 67
SONET/SDH OC3/STM1 PIC with SFP (M10i Router) . . . . . . . . . . . . . . . . . . . . . . . 77
SONET/SDH OC3/STM1 Enhanced IQ (IQE) PIC with SFP (M10i Router) . . . . . . 80
SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP (M10i Router) . . . . . . . . . . . . 82
SONET/SDH OC12/STM4 (Multi-Rate) PIC with SFP (M10i Router) . . . . . . . . . . 85
Copyright © 2018, Juniper Networks, Inc.
Table of Contents
Gigabit Ethernet IQ EOL PIC with SFP (M10i Router) . . . . . . . . . . . . . . . . . . . . . . . 111
Gigabit Ethernet IQ2 EOL PIC with SFP (M10i Router) . . . . . . . . . . . . . . . . . . . . . . 112
Adaptive Services II Layer 2 Services EOL PIC (M10i Router) . . . . . . . . . . . . . . . . 118
SONET/SDH OC3c/STM1 EOL PIC (M10i Router) . . . . . . . . . . . . . . . . . . . . . . . . . 125
SONET/SDH OC12c/STM4 EOL PIC (M10i Router) . . . . . . . . . . . . . . . . . . . . . . . . 127
SONET/SDH OC12/STM4 Enhanced IQ (IQE) EOL PIC with SFP (M10i
SONET/SDH OC48c/STM16 EOL PIC with SFP . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Copyright © 2018, Juniper Networks, Inc.
v
M10i Multiservice Edge Router Interface Module Reference vi Copyright © 2018, Juniper Networks, Inc.
List of Figures
Channelized Enhanced IQ (IQE) PIC Descriptions . . . . . . . . . . . . . . . . . . . . . 33
Copyright © 2018, Juniper Networks, Inc.
vii
M10i Multiservice Edge Router Interface Module Reference viii Copyright © 2018, Juniper Networks, Inc.
List of Tables
Table 4: End-of-Life PICs Supported in the M10i Router . . . . . . . . . . . . . . . . . . . . . 6
Table 6: Fast Ethernet 100BASE-FX Optical Interface Specifications . . . . . . . . . . 14
Table 7: SONET/SDH OC3/STM1 Multimode Optical Interface Specifications . . . 14
Table 8: SONET/SDH OC3/STM1 Intermediate Reach Optical Interface
Table 9: SONET/SDH OC3/STM1 Long Reach -1 Optical Interface
Table 10: SONET/SDH OC12/STM4 Short Reach (SR-1) Optical Interface
Table 11: SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Optical Interface
Table 12: SONET/SDH OC12/STM4 Long Reach (LR-1) Optical Interface
Table 13: SONET/SDH OC12/STM4 Long Reach (LR-2) Optical Interface
Table 14: SONET/SDH OC48/STM16 Short Reach (SR-1) Optical Interface
Table 15: SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Optical Interface
Table 16: SONET/SDH OC48/STM16 Long Reach (LR-1) Optical Interface
Table 17: SONET/SDH OC48/STM16 Long Reach (LR-2) Optical Interface
Table 18: RJ-48 Connector to RJ-48 Connector (Straight) Pinout for the
Table 19: RJ-48 Connector to RJ-48 Connector (Crossover) Pinout for the
Copyright © 2018, Juniper Networks, Inc.
ix
M10i Multiservice Edge Router Interface Module Reference
Table 20: RJ-48 Connector to DB-15 Connector (Straight) Pinout for the
Table 21: RJ-48 Connector to DB-15 Connector (Crossover) Pinout for the
Table 22: Multiservices PICs Software Features Supported by the M10i
Table 23: Adaptive Services PICs Software Features . . . . . . . . . . . . . . . . . . . . . . . 116
Table 24: Adaptive Services PICs Software Features . . . . . . . . . . . . . . . . . . . . . . . 119
x Copyright © 2018, Juniper Networks, Inc.
About the Documentation
•
Documentation and Release Notes on page xi
•
Documentation Conventions on page xi
•
Documentation Feedback on page xiii
•
Requesting Technical Support on page xiv
Documentation and Release Notes
To obtain the most current version of all Juniper Networks
® technical documentation, see the product documentation page on the Juniper Networks website at https://www.juniper.net/documentation/ .
If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
Juniper Networks Books publishes books by Juniper Networks engineers and subject matter experts. These books go beyond the technical documentation to explore the nuances of network architecture, deployment, and administration. The current list can be viewed at https://www.juniper.net/books .
Documentation Conventions
defines notice icons used in this guide.
Copyright © 2018, Juniper Networks, Inc.
xi
M10i Multiservice Edge Router Interface Module Reference
Table 1: Notice Icons
Icon Meaning
Informational note
Caution
Warning
Laser warning
Tip
Best practice
Description
Indicates important features or instructions.
Indicates a situation that might result in loss of data or hardware damage.
Alerts you to the risk of personal injury or death.
Alerts you to the risk of personal injury from a laser.
Indicates helpful information.
Alerts you to a recommended use or implementation.
defines the text and syntax conventions used in this guide.
Table 2: Text and Syntax Conventions
Convention Description Examples
Bold text like this
Fixed-width text like this
Represents text that you type.
Represents output that appears on the terminal screen.
To enter configuration mode, type the configure command: user@host> configure user@host> show chassis alarms
No alarms currently active
Italic text like this
Italic text like this
•
•
•
Introduces or emphasizes important new terms.
Identifies guide names.
Identifies RFC and Internet draft titles.
•
•
•
A policy term is a named structure that defines match conditions and actions.
Junos OS CLI User Guide
RFC 1997, BGP Communities Attribute
Represents variables (options for which you substitute a value) in commands or configuration statements.
Configure the machine’s domain name:
[edit] root@# set system domain-name domain-name xii Copyright © 2018, Juniper Networks, Inc.
About the Documentation
Table 2: Text and Syntax Conventions (continued)
Convention Description
Text like this
< > (angle brackets)
| (pipe symbol)
Examples
Represents names of configuration statements, commands, files, and directories; configuration hierarchy levels; or labels on routing platform components.
•
•
To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.
The console port is labeled CONSOLE .
Encloses optional keywords or variables.
stub <default-metric metric >;
Indicates a choice between the mutually exclusive keywords or variables on either side of the symbol. The set of choices is often enclosed in parentheses for clarity.
broadcast | multicast
( string1 | string2 | string3 )
# (pound sign)
[ ] (square brackets)
Indention and braces ( { } )
; (semicolon)
Indicates a comment specified on the same line as the configuration statement to which it applies.
rsvp { # Required for dynamic MPLS only
Encloses a variable for which you can substitute one or more values.
Identifies a level in the configuration hierarchy.
Identifies a leaf statement at a configuration hierarchy level.
community name members [ community-ids ]
[edit] routing-options { static { route default { nexthop address; retain;
}
}
}
GUI Conventions
Bold text like this
> (bold right angle bracket)
Represents graphical user interface (GUI) items you click or select.
•
•
In the Logical Interfaces box, select
All Interfaces .
To cancel the configuration, click
Cancel .
Separates levels in a hierarchy of menu selections.
In the configuration editor hierarchy, select Protocols>Ospf .
Documentation Feedback
We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods:
• Online feedback rating system—On any page of the Juniper Networks TechLibrary site at https://www.juniper.net/documentation/index.html
, simply click the stars to rate the content, and use the pop-up form to provide us with information about your experience.
Alternately, you can use the online feedback form at https://www.juniper.net/documentation/feedback/ .
Copyright © 2018, Juniper Networks, Inc.
xiii
M10i Multiservice Edge Router Interface Module Reference
• E-mail—Send your comments to [email protected]
. Include the document or topic name, URL or page number, and software version (if applicable).
Requesting Technical Support
Technical product support is available through the Juniper Networks Technical Assistance
Center (JTAC). If you are a customer with an active J-Care or Partner Support Service support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.
• JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at https://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf
.
• Product warranties—For product warranty information, visit https://www.juniper.net/support/warranty/ .
• JTAC hours of operation—The JTAC centers have resources available 24 hours a day,
7 days a week, 365 days a year.
Self-Help Online Tools and Resources
For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:
• Find CSC offerings: https://www.juniper.net/customers/support/
• Search for known bugs: https://prsearch.juniper.net/
• Find product documentation: https://www.juniper.net/documentation/
• Find solutions and answer questions using our Knowledge Base: https://kb.juniper.net/
• Download the latest versions of software and review release notes: https://www.juniper.net/customers/csc/software/
• Search technical bulletins for relevant hardware and software notifications: https://kb.juniper.net/InfoCenter/
• Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/
• Open a case online in the CSC Case Management tool: https://www.juniper.net/cm/
To verify service entitlement by product serial number, use our Serial Number Entitlement
(SNE) Tool: https://entitlementsearch.juniper.net/entitlementsearch/
Opening a Case with JTAC
You can open a case with JTAC on the Web or by telephone.
• Use the Case Management tool in the CSC at https://www.juniper.net/cm/ .
• Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).
xiv Copyright © 2018, Juniper Networks, Inc.
About the Documentation
For international or direct-dial options in countries without toll-free numbers, see https://www.juniper.net/support/requesting-support.html
.
Copyright © 2018, Juniper Networks, Inc.
xv
M10i Multiservice Edge Router Interface Module Reference xvi Copyright © 2018, Juniper Networks, Inc.
PART 1
Overview
•
M10i Interface Modules Support on page 3
•
Network Interface Specifications on page 13
•
Copyright © 2018, Juniper Networks, Inc.
1
M10i Multiservice Edge Router Interface Module Reference
2 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 1
M10i Interface Modules Support
•
•
M10i End-of-Life PICs Supported on page 6
•
M10i PIC/CFEB Compatibility on page 8
M10i PICs Supported
lists the PICs supported in the M10i router. The PICs are listed alphabetically by PIC family.
NOTE: The M10i router is now end-of-life. See the JTAC support bulletin
TSB16809 for additional information about the PICs and other associated
FRUs that moved to end-of-life with the router. The
topic lists PICs that moved to end-of-life before the
M10i router itself moved to end-of-life.
Table 3: PICs Supported in the M10i Router
Connector
First
Junos OS
Release
Support PIC Family and Type
ATM2 IQ
“ATM2 DS3 IQ PIC (M10i Router)” on page 27
Ports Model Number
4 PE-4DS3-ATM2 Coaxial:
•
•
10 ft (3.05-m) posilock SMB to BNC (provided)
Four pairs of Rx and Tx coaxial cables
6.1
• SC/PC 6.0
“ATM2 OC3/STM1 IQ PIC (M10i Router)” on page 29
2
1
Channelized Enhanced IQ (IQE)
PE-2OC3-ATM2-MM
PE-2OC3-ATM2-SMIR
PE-1OC12-ATM2-MM
PE-1OC12-ATM2-SMIR
• SC/PC 6.0
Copyright © 2018, Juniper Networks, Inc.
3
M10i Multiservice Edge Router Interface Module Reference
Table 3: PICs Supported in the M10i Router (continued)
PIC Family and Type
“Channelized DS3 and E3 Enhanced IQ
(IQE) PIC (M10i Router)” on page 33
4
NOTE: Only the DS3 interface is channelized.
“Channelized E1/T1 Enhanced IQ (IQE)
10
“Channelized OC3/STM1 Enhanced IQ
(IQE) with SFP (M10i Router)” on page 38
2
“Channelized OC12/STM4 Enhanced IQ
(IQE) PIC with SFP (M10i Router)” on page 43
1
Ports Model Number
PE-4CHDS3-E3-IQE-BNC
Connector
First
Junos OS
Release
Support
• Standard DS3 BNC coaxial cable interfaces
10.2
PE-10CHE1-T1-IQE-RJ48
PE-2CHOC3-STM1-IQE-SFP
• 120-ohm RJ-48C connector
(female)
10.2
• LC/PC 10.2
PE-1CHOC12STM4-IQE-SFP • LC/PC 10.2
Circuit Emulation
Emulation PIC with SFP (M10I Router)” on page 49
4
“E1/T1 Circuit Emulation PIC (M10i
12
PE-4CHOC3-CE-SFP
PE-12T1E1-CE-TELCO
• LC/PC 9.3
• RJ-21
NOTE: Cables are rated for intra-building connections only.
9.3
DS3, E1, E3, and T1
“DS3/E3 Enhanced IQ (IQE) PIC (M10i
4
“E1 PIC (M10i Router)” on page 59
4
“E3 IQ PIC (M10i Router)” on page 61
4
PE-4DS3-E3-IQE-BNC
PE-4E1-RJ48
PE-4E3-QPP
• Standard DS3 BNC coaxial cable interfaces
10.2
• Four RJ-48 connectors (one per port)
6.0
• Standard E3 BNC coaxial cable interfaces
6.1
Ethernet
“Fast Ethernet PICs (M10i Router)” on page 63
4 PE-4FE-TX
“Gigabit Ethernet PIC with SFP (M10i
1 PE-1GE-SFP
• Two-pair, Category 5 unshielded twisted-pair connectivity through an
RJ-45 connector
• Pinout: MDI noncrossover
• LC/PC
6.0
6.3
4 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: M10i Interface Modules Support
Table 3: PICs Supported in the M10i Router (continued)
First
Junos OS
Release
Support PIC Family and Type Ports Model Number
Ethernet Enhanced IQ2 (IQ2E)
“Gigabit Ethernet Enhanced IQ2 (IQ2E)
PIC with SFP (M10i Router)” on page 67
4
Services
“Multiservices 100 PIC (M10i Router)” on page 71
0
“Tunnel Services PIC (M10i Router)” on page 73
0
Serial
“EIA-530 PIC (M10i Router)” on page 75
2
PE-4GE-TYPE1-SFP-IQ2E
PE-MS-100-1
PE-TUNNEL
PE-2EIA530
Connector
• Duplex LC/PC connector
(Rx and Tx)
• None
• None
9.4
8.1
6.0
•
•
Two DB-25 male connectors
(one per port, included with
PIC)
V.35 requires an EIA-530 to
V.35 cable and connects to a V.35 DTE 34-pin
Winchester type male cable
(one per port)
• X.21 requires an EIA-530 to
X.21 cable and connects to a X.21 DTE DB-15 male cable
6.0
SONET/SDH
“SONET/SDH OC3/STM1 PIC with SFP
2
“SONET/SDH OC3/STM1 Enhanced IQ
(IQE) PIC with SFP (M10i Router)” on page 80
4
“SONET/SDH OC3/STM1 (Multi-Rate)
PIC with SFP (M10i Router)” on page 82
4
“SONET/SDH OC12/STM4 (Multi-Rate)
PIC with SFP (M10i Router)” on page 85
1
PE-2OC3-SON-SFP
PE-4OC3-STM1-IQE-SFP
PE-4OC3-1OC12-SON-SFP • LC/PC
PE-1OC12-SON-SFP
• LC/PC
• LC/PC
• LC/PC
8.4
10.2
8.4
8.4
Related
Documentation
• M10i PICs Description
•
M10i End-of-Life PICs Supported on page 6
•
M10i PIC/CFEB Compatibility on page 8
Copyright © 2018, Juniper Networks, Inc.
5
M10i Multiservice Edge Router Interface Module Reference
M10i End-of-Life PICs Supported
lists the end-of-life PICs supported in the M10i router. The PICs are listed alphabetically by PIC family.
NOTE: The M10i router is now end-of-life. See the JTAC support bulletin
TSB16809 for additional information about the PICs and other associated
FRUs that moved to end-of-life with the router. The
“M10i PICs Supported” on page 3
topic lists PICs that had not moved to end-of-life before the M10i router itself moved to end-of-life.
Table 4: End-of-Life PICs Supported in the M10i Router
Model Number
First Junos OS
Release
Support PIC Family and Type
ATM
“ATM DS3 EOL PIC (M10i Router)” on page 90
“ATM E3 EOL PIC (M10i Router)” on page 91
Ports
ATM2 IQ
“ATM2 E3 IQ EOL PIC (M10i Router)” on page 93
2
Channelized
“Multichannel DS3 EOL PIC (M10i Router)” on page 94
2
4
4
Channelized IQ
“Channelized DS3 IQ EOL PIC (M10i Router)” on page 96
4
“Channelized E1 IQ EOL PIC (M10i Router)” on page 97
10
10
PE-4DS3-ATM
PE-4E3-ATM
PE-2E3-ATM2
PE-2CHDS3
PE-4CHDS3-QPP
PE-10CHE1-RJ48-QPP
PE-10CHE1-RJ48-QPP-N
PE-1CHOC3-SMIR-QPP
6.1
6.1
6.1
6.1
6.0
6.0
9.1R4
9.2R3
9.3
7.6
“Channelized OC3 IQ EOL PIC (M10i Router)” on page 99
“Channelized OC12 IQ EOL PIC (M10i Router)” on page 100
1
1
“Channelized STM1 IQ EOL PIC (M10i Router)” on page 102
1
“Channelized T1 IQ EOL PIC (M10i Router)” on page 104
10
PE-1CHOC12SMIR-QPP
PE-1CHSTM1-SMIR-QPP
PE-10CHT1-RJ48-QPP
6.1
6.0
7.4
6 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: M10i Interface Modules Support
Table 4: End-of-Life PICs Supported in the M10i Router (continued)
PIC Family and Type
DS3, E1, E3, T1
“DS3 EOL PIC (M10i Router)” on page 106
Ports Model Number
“E1 PIC (M10i Router)” on page 59
“E3 PIC (M10i Router)” on page 107
“T1 EOL PIC (M10i Router)” on page 109
Ethernet
“Fast Ethernet PICs (M10i Router)” on page 63
4
2
2
4
4
8
12
“Gigabit Ethernet EOL PIC (M10i Router)” on page 110
1
PE-2DS3
PE-4DS3
PE-4E1-COAX
PE-2E3
PE-4T1-RJ48
PE-8FE-FX
PE-12FE-TX-MDI
PE-12FE-TX-MDIX
PE-1GE-LH
PE-1GE-LX
PE-1GE-SX
Ethernet IQ
“Gigabit Ethernet IQ EOL PIC with SFP (M10i Router)” on page 111
1
Ethernet IQ2
“Gigabit Ethernet IQ2 EOL PIC with SFP (M10i Router)” on page 112
4
Services
“Adaptive Services EOL PIC (M10i Router)” on page 114
0
“Adaptive Services II EOL PIC (M10i Router)” on page 116
0
“Adaptive Services II Layer 2 Services EOL PIC (M10i
“Adaptive Services II FIPS EOL PIC (M10i Router)” on page 120
“ES EOL PIC (M10i Router)” on page 122
0
0
0
PE-1GE-SFP-QPP
PE-4GE-TYPE1-SFP-IQ2
PE-AS
PE-AS2
PB-AS2-LAYER2SERVICES
PE-AS2-FIPS
PE-ES-800
6.0
7.6R3
7.2
6.1
6.1
6.4
8.0R2
First Junos OS
Release
Support
6.0
6.0
6.0
6.0
6.0
6.1
6.0
6.1
Copyright © 2018, Juniper Networks, Inc.
7
M10i Multiservice Edge Router Interface Module Reference
Table 4: End-of-Life PICs Supported in the M10i Router (continued)
PIC Family and Type
“Link Services EOL PIC (M10i Router)” on page 123
Ports
0
Model Number
PE-LS-4
PE-LS-32
PE-LS-128
PE-PM
“Monitoring Services EOL PIC (M10i Router)” on page 124
0
SONET/SDH
“SONET/SDH OC3c/STM1 EOL PIC (M10i Router)” on page 125
2
4
“SONET/SDH OC12c/STM4 EOL PIC (M10i Router)” on page 127
1
“SONET/SDH OC12/STM4 Enhanced IQ (IQE) EOL PIC with SFP (M10i Router)” on page 129
1
“SONET/SDH OC48c/STM16 EOL PIC with SFP” on page 132
1
PE-2OC3-SON-MM
PE-2OC3-SON-SMIR
PE-4OC3-SON-MM
PE-4OC3-SON-SMIR
PE-1OC12-SON-MM
PE-1OC12-SON-SMIR
PE-1OC12-STM4-IQE-SFP
PE-1OC48-SON-SFP
6.0
6.0
6.0
10.2
6.4
First Junos OS
Release
Support
6.1
6.1
Related
Documentation
• M10i PICs Description
•
•
M10i PIC/CFEB Compatibility on page 8
M10i PIC/CFEB Compatibility
lists the PICs and CFEBs supported on the M10i router.
Table 5: PICs Supported in the M10i Router
PIC Family and Type Ports Model Number CFEB CFEB-E
ATM
4
“ATM E3 EOL PIC (M10i Router)” on page 91
4
PE-4DS3-ATM
EOL (see notification PSN-2003-10-018 )
PE-4E3-ATM
EOL (see notification PSN-2003-10-018 )
6.1
6.1
ATM2 IQ
ATM2 DS3 IQ 4 PE-4DS3-ATM2 6.1
9.4
8 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: M10i Interface Modules Support
Table 5: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
ATM2 E3 IQ
ATM2 OC3/STM1 IQ
ATM2 OC12/STM4 IQ
2
2
1
PE-2E3-ATM2
PE-2OC3-ATM2-MM
PE-2OC3-ATM2-SMIR
PE-1OC12-ATM2-MM
PE-1OC12-ATM2-SMIR
Channelized
2 PE-2CHDS3
EOL (see notification PSN-2004-10-026 )
Channelized IQ
Channelized DS3 IQ
Channelized E1 IQ
4
10
PE-4CHDS3-QPP
PE-10CHE1-RJ48-QPP-N
PE-1CHOC12SMIR-QPP
PE-1CHOC3-SMIR-QPP
PE-1CHSTM1-SMIR-QPP
PE-10CHT1-RJ48-QPP
CFEB
6.1
6.1
6.1
6.1
7.1
6.1
7.4
6.1
9.1R4
9.2R3
9.3
Channelized OC12 IQ
Channelized OC3 IQ
Channelized STM1 IQ
Channelized T1 IQ
Channelized IQE
Channelized DS3 and E3
Enhanced IQ (IQE)
4
Channelized E1/T1 Enhanced IQ
(IQE)
10
Channelized OC3/STM1
Enhanced IQ (IQE) with SFP
2
Channelized OC12/STM4
Enhanced IQ (IQE) PIC with SFP
1
1
10
1
1
Circuit Emulation
Channelized OC3/STM1 Circuit
Emulation
4
E1/T1 Circuit Emulation 12
DS3, E1, E3, and T1
PE-4CHDS3-E3–IQE-BNC
PE-10CHE-T1-IQE-RJ48
PE-2CHOC3-STM1-IQE-SFP
PE-1CHOC12STM4-IQE-SFP
PE-4CHOC3-CE-SFP
PE-12T1E1-CE-TELCO
–
–
–
–
9.3
9.3
9.4
9.4
9.4
9.4
9.4
9.4
9.5
9.5
10.2
10.2
10.2
10.2
CFEB-E
9.4
9.4
9.4
Copyright © 2018, Juniper Networks, Inc.
9
M10i Multiservice Edge Router Interface Module Reference
Table 5: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
DS3
DS3/E3 Enhanced IQ (IQE)
E1
E3
E3 IQ
T1
2
4
4
4
4
2
4
PE-2DS3
PE-4DS3
PE-4DS3-E3-IQE-BNC
PE-4E1-COAX
PE-4E1-RJ48
PE-2E3
PE-4E3-QPP
PE-4T1-RJ48
E3
“E3 PIC (M10i Router)” on page 107
4 PE-4E3
EOL (see notification PSN-2003-10-018 )
Ethernet
Fast Ethernet
“Gigabit Ethernet EOL PIC (M10i
1
4
8
12
1
PE-4FE-TX
PE-8FE-FX
PE-12FE-TX-MDI
PE-12FE-TX-MDIX
PE-1GE-LH
EOL (see notification PSN-2004-06-014 )
PE-1GE-LX
EOL (see notification PF-HW-0103-001 )
PE-1GE-SX
EOL (see notification PF-HW-0103-001 )
PE-1GE-SFP Gigabit Ethernet with SFP
Ethernet IQ
Gigabit Ethernet IQ 1 PE-1GE-SFP-QPP
Ethernet IQ2
Gigabit Ethernet IQ2 4
Ethernet Enhanced IQ2 (IQ2E)
Gigabit Ethernet IQ2E 4
Services
PE-4GE-TYPE1-SFP-IQ2
PE-4GE-TYPE1-SFP-IQ2E
6.0
6.1
6.1
CFEB
–
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.1
6.3
6.1
7.6R3
9.4
9.4
9.4
9.4
9.4
9.4
9.4
9.5R2
9.4
9.4
9.4
CFEB-E
9.4
9.4
10.2
9.4
10 Copyright © 2018, Juniper Networks, Inc.
Chapter 1: M10i Interface Modules Support
Table 5: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
Link Services 0
0
PE-LS-4
PE-LS-32
PE-LS-128
PE-MS-100-1
0
0
0
PE-TUNNEL
PE-AS
EOL (see notification PSN-2005-06-007 )
PE-AS2
EOL (see notification PSN-2007-12-036 )
Services EOL PIC (M10i Router)” on page 118
0
“Adaptive Services II FIPS EOL
PIC (M10i Router)” on page 120
0
PB-AS2-LAYER2SERVICES
EOL (see notification PSN-2008-11-080 )
“ES EOL PIC (M10i Router)” on page 122
0
0
0
PE-AS2-FIPS
EOL (see notification PSN-20011-09-381 )
PE-ES-800
EOL (see notification PSN-2010-04-734 )
PE-LS-4
EOL (see notification PSN-2008-11-080 )
PE-LS-32
EOL (see notification PSN-2008-11-080 )
PE-LS-128
EOL (see notification PSN-2008-11-080 )
PE-PM
EOL (see notification PSN-2005-06-007 )
Serial
EIA-530 2
SONET/SDH
“SONET/SDH OC3/STM1 PIC with SFP (M10i Router)” on page 77
2
Enhanced IQ (IQE) PIC with SFP
4
PE-2EIA530
PE-2OC3-SON-SFP
PE-4OC3-STM1-IQE-SFP
CFEB
6.1
8.1
6.1
6.1
6.4
8.0R2
6.0
6.0
6.1
6.1
8.4
–
CFEB-E
–
9.4
9.4
9.4
9.4
9.6
10.2
Copyright © 2018, Juniper Networks, Inc.
11
M10i Multiservice Edge Router Interface Module Reference
Table 5: PICs Supported in the M10i Router (continued)
PIC Family and Type Ports Model Number
PE-4OC3-1OC12-SON-SFP
(Multi-Rate) PIC with SFP (M10i
4
Enhanced IQ (IQE) EOL PIC with
SFP (M10i Router)” on page 129
1
(Multi-Rate) PIC with SFP (M10i
1
1
PIC (M10i Router)” on page 125
2
• SONET/SDH OC3c/STM1 PIC 2
PE-1OC12-STM4-IQE-SFP
PE-1OC12-SON-SFP
PE-1OC48-SON-SFP
PE-2OC3-SON
EOL (see notification PSN-2007-12-037 )
• SONET/SDH OC3c/STM1 PIC 4
PE-2OC3-SON-MM
PE-2OC3-SON-SMIR
PE-4OC3-SON-MM
PE-4OC3-SON-SMIR
PIC (M10i Router)” on page 127
1 PE-1OC12-SON-MM
EOL (see notification PSN-2007-12-037 )
PE-1OC12-SON-SMIR
EOL (see notification PSN-2007-12-037 )
Related
Documentation
• M10i PICs Description
•
CFEB
8.4
–
8.4
6.4
6.0
6.0
CFEB-E
9.4
10.2
9.4
–
9.4
9.4
12 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 2
Network Interface Specifications
•
Determining Transceiver Support and Specifications for M Series and T Series
•
Fast Ethernet 100BASE-FX Optical Interface Specifications on page 13
•
SONET/SDH OC3/STM1 Optical Interface Specifications on page 14
•
SONET/SDH OC12/STM4 Optical Interface Specifications on page 16
•
SONET/SDH OC48/STM16 Optical Interface Specifications on page 18
Determining Transceiver Support and Specifications for M Series and T Series Routers
You can find information about the pluggable transceivers supported on your Juniper
Networks device by using the Hardware Compatibility Tool. In addition to transceiver and connector type, the optical and cable characteristics—where applicable—are documented for each transceiver. The Hardware Compatibility Tool allows you to search by product, displaying all the transceivers supported on that device, or category, displaying all the transceivers by interface speed or type. The Hardware Compatibility Tool is located at https://apps.juniper.net/hct/ .
Some transceivers support additional monitoring using the operational mode CLI command show interfaces diagnostics optics . Use the Hardware Compatibility Tool to determine if your transceiver supports monitoring. See the Junos OS documentation for your device for a description of the monitoring fields.
CAUTION: If you face a problem running a Juniper Networks device that uses a third-party optic or cable, the Juniper Networks Technical Assistance Center
(JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.
Fast Ethernet 100BASE-FX Optical Interface Specifications
shows the optical interface specifications for the 100BASE-FX standard.
Copyright © 2018, Juniper Networks, Inc.
13
M10i Multiservice Edge Router Interface Module Reference
Table 6: Fast Ethernet 100BASE-FX Optical Interface Specifications
Parameter 100BASE-FX
Rate
Optical interface
Maximum distance
Transmitter wavelength
Average launch power
Average receive power
100 Mbps
Multimode
50/125 MMF cable:
1640 ft (500 m)
62.5/125 MMF cable:
6562 ft (2 km)
1270 through 1380 nm
–19 through –14 dBm
–31 through –14 dBm
Receiver saturation
Receiver sensitivity
–14 dBm
–31 dBm
SONET/SDH OC3/STM1 Optical Interface Specifications
•
SONET/SDH OC3/STM1 Specifications on page 14
•
SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications on page 15
•
SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications on page 15
SONET/SDH OC3/STM1 Specifications
shows the multimode SONET/SDH OC3/STM1 optical interface specifications.
Table 7: SONET/SDH OC3/STM1 Multimode Optical Interface Specifications
Parameter Multimode
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Multimode
MMF cable: 1.2 miles (2 km)
Multivendor agreement
1270 through 1380 nm
–20 through –14 dBm
–14 dBm
14 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 7: SONET/SDH OC3/STM1 Multimode Optical Interface Specifications (continued)
Parameter Multimode
Receiver sensitivity –30 dBm
SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications
shows the SONET/SDH OC3/STM1 intermediate reach (IR-1) optical interface specifications.
Table 8: SONET/SDH OC3/STM1 Intermediate Reach Optical Interface Specifications
Parameter Intermediate Reach (IR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 9.3 miles (15 km)
Telcordia GR-253
1261 through 1360 nm
–15 through –8 dBm
–8 dBm
–28 dBm
SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications
shows the SONET/SDH OC3/STM1 long reach (LR-1) optical interface specifications.
Table 9: SONET/SDH OC3/STM1 Long Reach -1 Optical Interface Specifications
Parameter Long Reach (LR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 24.85 miles (40 km)
Telcordia GR-253
1263 through 1360 nm
–5 through 0 dBm
–10 dBm
–34 dBm
Copyright © 2018, Juniper Networks, Inc.
15
M10i Multiservice Edge Router Interface Module Reference
SONET/SDH OC12/STM4 Optical Interface Specifications
•
SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications on page 16
•
SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications on page 16
•
SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications on page 17
•
SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications on page 17
SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications
shows the SONET/SDH OC12/STM4 short reach (SR-1) optical interface specifications.
Table 10: SONET/SDH OC12/STM4 Short Reach (SR-1) Optical Interface Specifications
Parameter Short Reach (SR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 1.24 miles (2 km)
Telcordia GR-253
1261 through 1360 nm
–15 through –8 dBm
–8 dBm
–23 dBm
SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications
shows the SONET/SDH OC12/STM4 short reach (IR-1) optical interface specifications.
Table 11: SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Optical Interface
Specifications
Parameter Intermediate Reach (IR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Single-mode
SMF cable: 9.3 miles (15 km)
Telcordia GR-253
1274 through 1356 nm
–15 through –8 dBm
16 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 11: SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Optical Interface
Specifications (continued)
Parameter Intermediate Reach (IR-1)
Receiver saturation
Receiver sensitivity
–8 dBm
–28 dBm
SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications
shows the SONET/SDH OC12/STM4 short reach (LR-1) optical interface specifications.
Table 12: SONET/SDH OC12/STM4 Long Reach (LR-1) Optical Interface Specifications
Parameter Long Reach (LR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 24.85 miles (40 km)
Telcordia GR-253
1280 through 1335 nm
–3 through +2 dBm
–8 dBm
–28 dBm
SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications
shows the SONET/SDH OC12/STM4 short reach (LR-2) optical interface specifications.
Table 13: SONET/SDH OC12/STM4 Long Reach (LR-2) Optical Interface Specifications
Parameter Long Reach (LR-2)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Single-mode
SMF cable: 49.70 miles (80 km)
Telcordia GR-253
1480 through 1580 nm
–3 through 2 dBm
–8 dBm
Copyright © 2018, Juniper Networks, Inc.
17
M10i Multiservice Edge Router Interface Module Reference
Table 13: SONET/SDH OC12/STM4 Long Reach (LR-2) Optical Interface
Specifications (continued)
Parameter Long Reach (LR-2)
Receiver sensitivity –28 through –8 dBm
SONET/SDH OC48/STM16 Optical Interface Specifications
•
SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications on page 18
•
SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications on page 18
•
SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications on page 19
•
SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications on page 19
SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications
shows the SONET/SDH OC48/STM16 short reach (SR-1) optical interface specifications.
Table 14: SONET/SDH OC48/STM16 Short Reach (SR-1) Optical Interface Specifications
Parameter Short Reach (SR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 1.24 miles (2 km)
Telcordia GR-253
1266 through 1360 nm
–10 through –3 dBm
–3 dBm
–18 dBm
SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications
shows the SONET/SDH OC48/STM16 intermediate reach (IR-1) optical interface specifications.
Table 15: SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Optical Interface
Specifications
Parameter Intermediate Reach (IR-1)
Optical interface
Maximum distance
Single-mode
SMF cable: 9.3 miles (15 km)
18 Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Network Interface Specifications
Table 15: SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Optical Interface
Specifications (continued)
Parameter Intermediate Reach (IR-1)
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Telcordia GR-253
1260 through 1360 nm
–5 through 0 dBm
0 dBm
–18 dBm
SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications
shows the SONET/SDH OC48/STM16 long reach (LR-1) optical interface specifications.
Table 16: SONET/SDH OC48/STM16 Long Reach (LR-1) Optical Interface Specifications
Parameter Long Reach (LR-1)
Optical interface
Maximum distance
Standard
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
Single-mode
SMF cable: 28.85 miles (40 km)
Telcordia GR-253
1280 through 1335 nm
–2 through +3 dBm
–9 dBm
–28 dBm
SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications
shows the SONET/SDH OC48/STM16 long reach (LR-2) optical interface specifications.
Table 17: SONET/SDH OC48/STM16 Long Reach (LR-2) Optical Interface Specifications
Parameter Long Reach (LR-2)
Optical interface
Maximum distance
Standard
Single-mode
SMF cable: 49.71 miles (80 km)
Telcordia GR-253
Copyright © 2018, Juniper Networks, Inc.
19
M10i Multiservice Edge Router Interface Module Reference
Table 17: SONET/SDH OC48/STM16 Long Reach (LR-2) Optical Interface
Specifications (continued)
Parameter Long Reach (LR-2)
Transmitter wavelength
Average launch power
Receiver saturation
Receiver sensitivity
1500 through 1580 nm
–2 through +3 dBm
–9 dBm
–28 dBm
20 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 3
Cable Pinouts
•
RJ-48 Cable Pinouts for E1 and T1 PICs on page 21
RJ-48 Cable Pinouts for E1 and T1 PICs
The E1 and T1 PICs use an RJ-48 cable, which is not supplied with the PIC.
CAUTION: To maintain agency approvals, use only a properly constructed, shielded cable.
6
7
5
3
8
1
2
4
,
Table 19 on page 22 , Table 20 on page 22 , and
describe the RJ-48 connector pinouts.
Table 18: RJ-48 Connector to RJ-48 Connector (Straight) Pinout for the Router
RJ-48 Pin (on T1/E1 PIC)
(Data numbering form)
RJ-48 Pin
(Data numbering form) Signal
1
2
4
RX, Ring, –
RX, Tip, +
TX, Ring, –
5
3
6
No connect
No connect
TX, Tip, +
Shield/Return/Ground
Shield/Return/Ground
No connect
No connect
Copyright © 2018, Juniper Networks, Inc.
21
M10i Multiservice Edge Router Interface Module Reference
7
8
3
6
4
5
1
2
Table 19: RJ-48 Connector to RJ-48 Connector (Crossover) Pinout for the Router
RJ-48 Pin (on T1/E1 PIC)
(Data numbering form)
RJ-48 Pin
(Data numbering form) Signal
1
2
4
5
RX/Ring/– <––>TX/Ring/–
RX/Tip/+ <––>TX/Tip/+
TX/Ring/– <––>RX/Ring/–
TX/Tip/+ <––>RX/Tip/+
3
6
No connect
No connect
Shield/Return/Ground
Shield/Return/Ground
No connect
No connect
7
8
3
6
9
10
11
4
5
1
2
Table 20: RJ-48 Connector to DB-15 Connector (Straight) Pinout for the Router
RJ-48 Pin (on T1/E1 PIC)
(Data numbering form)
DB-15 Pin
(Data numbering form) Signal
9
1
11
3
RX/Ring/– <––>RX/Ring/–
RX/Tip/+ <––>RX/Tip/+
TX/Ring/– <––>TX/Ring/–
TX/Tip/+ <––>TX/Tip/+
4
2
No connect
No connect
No connect
No connect
No connect
Shield/Return/Ground
Shield/Return/Ground
No connect
No connect
No connect
No connect
No connect
22 Copyright © 2018, Juniper Networks, Inc.
14
15
12
13
Table 20: RJ-48 Connector to DB-15 Connector (Straight) Pinout for the
Router (continued)
RJ-48 Pin (on T1/E1 PIC)
(Data numbering form)
DB-15 Pin
(Data numbering form) Signal
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
11
12
9
10
13
14
15
3
6
4
5
7
8
Table 21: RJ-48 Connector to DB-15 Connector (Crossover) Pinout for the Router
RJ-48 Pin (on T1/E1 PIC)
(Data numbering form)
DB-15 Pin
(Data numbering form) Signal
1
2
9
1
RX/Ring/– <––>TX/Ring/–
RX/Tip/+ <––>TX/Tip/+
4
2
11
3
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
TX/Ring/– <––>RX/Ring/–
TX/Tip/+ <––>RX/Tip/+
Shield/Return/Ground
Shield/Return/Ground
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
No connect
Copyright © 2018, Juniper Networks, Inc.
Chapter 3: Cable Pinouts
23
M10i Multiservice Edge Router Interface Module Reference
Related
Documentation
• Maintaining M120 PICs and PIC Cables
• Installing an M120 PIC Cable
• M120 PICs Description
24 Copyright © 2018, Juniper Networks, Inc.
PART 2
PIC Descriptions
•
ATM2 IQ PIC Descriptions on page 27
•
Channelized Enhanced IQ (IQE) PIC Descriptions on page 33
•
Circuit Emulation PIC Descriptions on page 49
•
DS3, E1, E3, and T1 PIC Descriptions on page 57
•
Ethernet PIC Descriptions on page 63
•
Ethernet Enhanced IQ2 (IQ2E) PIC Descriptions on page 67
•
Services PIC Descriptions on page 71
•
Serial PIC Descriptions on page 75
•
SONET/SDH PIC Descriptions on page 77
•
End-of-Life PIC Descriptions on page 89
Copyright © 2018, Juniper Networks, Inc.
25
M10i Multiservice Edge Router Interface Module Reference
26 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 4
ATM2 IQ PIC Descriptions
•
ATM2 DS3 IQ PIC (M10i Router) on page 27
•
ATM2 OC3/STM1 IQ PIC (M10i Router) on page 29
•
ATM2 OC12/STM4 IQ PIC (M10i Router) on page 30
ATM2 DS3 IQ PIC (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 6.1 and later
•
•
•
•
Four DS3 ports
Power requirement: 0.41 A @ 48 V (20.0 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface.
ATM standards compliant
•
•
•
16-MB SDRAM memory for ATM segmentation and reassembly (SAR)
ATM switch ID
Configurable framing options:
•
•
•
•
C-bit with ATM direct mapping
C-bit with Physical Layer Convergence Protocol (PLCP) framing (default)
M23 ATM direct mapping
M23 with PLCP framing
• Internal and loop timing
Copyright © 2018, Juniper Networks, Inc.
27
M10i Multiservice Edge Router Interface Module Reference
Software features
•
•
•
•
•
Per-virtual circuit (VC) and per-virtual path (VP) traffic shaping
Unspecified bit rate (UBR) traffic shaping
Fine-grained variable bit rate (VBR) traffic shaping
Circuit cross-connect (CCC)
•
ATM Inverse Address Resolution Protocol (ARP), which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit (PVC)
Simple Network Management Protocol (SNMP):
•
•
•
Management Information Base (MIB) 2 (RFC 1213)
ATM MIB (RFC 1695)
SONET MIB
•
•
•
•
•
•
AAL5 encapsulations:
ATM-VC-MUX
ATM-NLPID
ATM-Cisco-LLPID
ATM-SNAP
ATM-CCC-VC-MUX
Cables and connectors Coaxial:
•
•
10 ft (3.05 m) posilock SMB to BNC (provided)
Four pairs of Rx and Tx coaxial cables
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Far-end block error (FEBE)
Frame error
Idle code
Idle received
Local and remote loopback
Loss of signal (LOS)
Out of frame (OOF)
Path parity error
Yellow alarm
Related
Documentation
• M10i PICs Description
•
28 Copyright © 2018, Juniper Networks, Inc.
Chapter 4: ATM2 IQ PIC Descriptions
ATM2 OC3/STM1 IQ PIC (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 6.0 and later
•
•
•
•
•
•
•
•
Two OC3 ports
Power requirement: 0.41 A @ 48 V (20 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
Conforms to ANSI T1.105-1991 and T1E1.2/93-020R1
ATM and SONET/SDH standards compliant
Alarm and event counting and detection
Compatible with well-known ATM switches
ATM switch ID, which displays the switch IP address and local interface name of the adjacent
Fore ATM switches
•
•
•
•
•
Single 3010 SAR for segmentation and reassembly into 53 byte ATM cells
High-performance parsing of SONET/SDH frames
ASIC-based packet segmentation and reassembly (SAR) management and output port queuing
64 MB SDRAM memory for ATM SAR
Packet buffering, Layer 2 parsing
•
•
•
•
•
•
•
Circuit cross-connect (CCC) for leveraging ATM access networks
User-configurable virtual circuit (VC) and virtual path (VP) support
Support for idle cell or unassigned cell transmission
OAM fault management processes alarm indication signal (AIS), remote defect indicator (RDI) cells, and loop cells
Point-to-point and point-to-multipoint mode Layer 2 counters per VC and per VP
Local and remote loopback
ATM Inverse Address Resolution Protocol (ARP), which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit (PVC)
•
•
•
•
Simple Network Management Protocol (SNMP):
Management Information Base (MIB) 2 (RFC 1213)
ATM MIB (RFC 1695)
SONET MIB
• Unspecified bit rate (UBR), non-real-time variable bit rate (VBR), and constant bit rate (CBR) traffic shaping
•
•
•
Per-VC or per-VP traffic shaping
Support for F4 OAM cells
Support for 16 bit VCI range
Copyright © 2018, Juniper Networks, Inc.
29
M10i Multiservice Edge Router Interface Module Reference
Cables and connectors •
•
Duplex SC/PC connector (RX and TX)
SONET/SDH OC3/STM1 fixed transceivers:
•
•
Multimode
Intermediate reach (IR-1)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
•
•
•
•
Loss of cell delineation (LOC), loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
ATM2 OC12/STM4 IQ PIC (M10i Router)
Software release • Junos OS Release 6.0 and later
30 Copyright © 2018, Juniper Networks, Inc.
Chapter 4: ATM2 IQ PIC Descriptions
Description
Hardware features
•
•
•
•
•
•
•
•
One OC12 port
Power requirement: 0.41 A @ 48 V (20 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
Conforms to ANSI T1.105-1991 and T1E1.2/93-020R1
Complies with ATM and SONET/SDH standards
Alarm and event counting and detection
Compatible with well-known ATM switches
ATM switch ID, which displays the switch IP address and local interface name of the adjacent
Fore ATM switches
•
•
•
•
•
One 3010 SAR for segmentation and reassembly into 53-byte ATM cells
High-performance parsing of SONET/SDH frames
ASIC-based packet segmentation and reassembly (SAR) management and output port queuing
64 MB SDRAM memory for ATM SAR
Packet buffering, Layer 2 parsing
Software features
•
•
•
•
Circuit cross-connect for leveraging ATM access networks
User-configurable virtual circuit (VC) and virtual path (VP) support
Support for idle cell or unassigned cell transmission
OAM fault management processes alarm indication signal (AIS), remote defect indication
(RDI), and loop cells
•
•
•
Point-to-point and point-to-multipoint mode Layer 2 counters per VC and per VP
Local and remote loopback
•
ATM Inverse ARP, which enables routers to automatically learn the IP address of the router on the far end of an ATM PVC
Simple Network Management Protocol (SNMP):
•
•
•
Management Information Base (MIB) 2 (RFC 1213)
ATM MIB (RFC 1695)
SONET MIB
• Unspecified bit rate (UBR), non-real-time variable bit rate (VBR), and constant bit rate (CBR) traffic shaping
Per-VC or per-VP traffic shaping •
•
•
Support for F4 OAM cells
Support for 16-bit VCI range
Cables and connectors •
•
Duplex SC/PC connector (Rx and Tx)
SONET/SDH OC12/STM4 fixed transceiver:
• Multimode
• Intermediate reach (IR-1)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface Specifications” on page 16
LEDs One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
Copyright © 2018, Juniper Networks, Inc.
31
M10i Multiservice Edge Router Interface Module Reference
Alarms, errors, and events
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
•
•
•
•
Loss of cell delineation (LOC), loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
32 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 5
RX
PORT 1 RX PORT 2 RX
Descriptions
•
Channelized DS3 and E3 Enhanced IQ (IQE) PIC (M10i Router) on page 33
•
Channelized E1/T1 Enhanced IQ (IQE) PIC (M10i Router) on page 36
•
Channelized OC3/STM1 Enhanced IQ (IQE) with SFP (M10i Router) on page 38
•
Channelized OC12/STM4 Enhanced IQ (IQE) PIC with SFP (M10i Router) on page 43
Channelized DS3 and E3 Enhanced IQ (IQE) PIC (M10i Router)
TX
TX
TX
TX
PORT 0
RX
PORT 1
RX
PORT 2
RX
PORT 3
RX
Software release
Description
Hardware features
Software features
• Junos OS Release 10.2 and later (Type 1)
•
•
•
Four E3 or Channelized DS3 ports
E3 or Channelized DS3 is configurable on a per-port granularity
DS3 channelization:
•
•
•
4 DS3 channels
112 DS1 channels
1011 DS0 channels
• Power requirement: 0.53 A @ 48 V (25.4 W)
• Ports are numbered 0 through 3 from left to right
•
•
•
Maximum transmission units (MTUs) of up to 9000 bytes
Dynamic, arbitrary channel configuration
Subrate and scrambling:
NOTE: Only DS3 interfaces support subrate and scrambling.
•
•
Digital Link/Quick Eagle
Kentrox
Copyright © 2018, Juniper Networks, Inc.
33
M10i Multiservice Edge Router Interface Module Reference
•
•
•
Larscom
ADTRAN
Verilink (subrate: only port A mode)
NOTE: For DS3 interfaces, Verilink does not function if an IQE interface is paired with an IQ interface.
•
•
•
•
•
•
•
•
•
Data service unit (DSU) functionality
B3ZS line encoding
Framing: M13, C-bit parity, framed clear channel
Full bit error rate test (BERT) for DS0, DS1, and DS3
ANSI T1.403 FDL
Internal and loop clocking for DS3 and DS1
DS3 far end alarm and control (FEAC) channel
Local line, remote line, and remote playback loopback testing for each DS3 and DS1channels
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
•
•
•
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
Simple Network Management Protocol (SNMP): DS1 MIB, DS3 MIB
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
Cables and connectors • Standard DS3 BNC coaxial cable interfaces
LEDs One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
34 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Alarms, errors, and events
Instrumentation
(counters)
•
•
Alarm reporting for error statistics and failure counts
DS1 alarms:
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Remote alarm indication signal (RAIS)
• DS1 error detection:
•
•
•
•
•
•
•
•
•
Bursty errored seconds (BES)
CRC errors
Errored seconds (ES)
Line errored seconds (LES)
Loss of framing seconds (LOFS)
Loss of signal seconds (LOSS)
Severely errored seconds (SES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• DS3 alarms:
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Loss of signal (LOS)
Phase lock loop (PLL)
• DS3 error detection:
•
•
•
•
•
•
•
•
•
•
•
•
•
C-bit code violations (CCV)
C-bit errored seconds (CES)
C-bit severely errored framing seconds (CEFS)
CRC errors
Excessive zeros (EXZ)
Far-end block error (FEBE)
Far-end receive failure (FERF)
Line errored seconds (LES)
Parity bit (P-bit) code violations (PCV)
Parity bit (P-bit) errored seconds (PES)
Parity bit (P-bit) severely errored framing seconds (PSES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
35
M10i Multiservice Edge Router Interface Module Reference
Channelized E1/T1 Enhanced IQ (IQE) PIC (M10i Router)
36
Software release
Description
Hardware features
Software features
• Junos OS Release 10.2 and later (Type 1)
•
•
•
Ten E1 or T1 ports
DS1 and E1 interfaces are selectable on a per-port granularity
•
•
E1 channelization per PIC:
10 E1 channels
310 DS0 channels
•
•
•
T1 channelization per PIC:
10 T1 channels
240 DS0 channels
•
•
Power requirement: 0.52 A @ 48 V (24.73 W)
Model number: PB-10CHE1-T1-IQE-RJ48
Ports are numbered:
•
•
•
•
Top row: 0 and 1 from left to right
Second row: 2 and 3 from left to right
Third row: 3 and 4 from left to right
Bottom row: 5 and 6 from left to right
•
•
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
•
•
•
•
•
Support sending and receiving in-band loopback codes in both framed and unframed mode:
Framed in-band loopback at CSU
Framed in-band loopback at Smartjack (ANSI)
Unframed in-band loopback at CSU
Unframed in-band loopback at Smartjack (ANSI)
•
•
•
You can configure the following framing modes using the CLI:
T1—SF (D4/superframe), ESF (extended superframe)
E1—G704, G704–no-crc4, unframed
•
•
Packet buffering, Layer 2 parsing
Local line, remote line, and remote payload loopback testing; each channel can be looped individually and independently of other channels (DS1/E1 channels)
•
•
Simple Network Management Protocol (SNMP): T1 MIB (RFC 1406)
Dynamic, arbitrary channel configuration
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
•
•
Full bit error rate test (BERT)
Clocking: internal and loop (clock recovered from network and use for transmit). Internal timing is the default for channelized T1 ports. The external master clock can be a multiple of 2.048
MHz or 1.544 MHz for E1 or T1 operation.
•
•
•
Line coding:
T1—CLI configurable as AMI or B8ZS
E1—HDB3
• Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
• Encapsulations available only for DS0 and DS1:
•
•
•
Multilink Frame Relay end-to-end (MLFR FRF.15)
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Multilink PPP (MLPPP)
• Encapsulations available only for DS1:
• PPP over Frame Relay
Cables and connectors • 120-ohm RJ-48C connector (female)
LEDs One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
Copyright © 2018, Juniper Networks, Inc.
37
M10i Multiservice Edge Router Interface Module Reference
Alarms, errors, and events
Instrumentation
(counters)
• DS1 alarms:
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Remote alarm indication signal (RAIS)
24-hour alarm reporting history maintained for error statistics and failure counts, 15-minute intervals on all errors
• DS1 error detection:
•
•
•
•
•
•
•
•
•
Bursty errored seconds (BES)
CRC errors
Errored seconds (ES)
Line errored seconds (LES)
Loss of framing seconds (LOFS)
Loss of signal seconds (LOSS)
Severely errored seconds (SES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
•
•
Layer 2 per-queue and per-channel packet and byte counters
Layer 2 per-queue and per-channel packet and byte drop counters
Related
Documentation
• M10i PICs Description
•
Channelized OC3/STM1 Enhanced IQ (IQE) with SFP (M10i Router)
PORT 1
TX
RX
PORT 0
RX
TX
Software release • Junos OS Release 10.2 and later
38 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Description
Hardware features
•
•
•
Two OC3 or STM1 ports
SONET or SDH is configurable on a per-port granularity
•
•
•
•
SONET channelization:
2 OC3 channels
6 DS3 channels
168 DS1 channels
1011 DS0 channels
•
•
•
•
•
•
•
SDH channelization:
2 STM1 channels (non-concatenated)
6 E3 channels
126 E1 channels
6 DS3 channels
168 DS1 channels
1011 DS0 channels
• Power requirement: 0.56 A @ 48 V (27.1 W)
• Ports are numbered 0 and 1 from left to right
Copyright © 2018, Juniper Networks, Inc.
39
M10i Multiservice Edge Router Interface Module Reference
40
Software features •
•
Dynamic, arbitrary channel configuration
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
•
•
•
•
•
•
•
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
Subrate and scrambling:
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
•
•
•
•
•
Packet buffering, Layer 2 parsing
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support
Local line, remote line, and remote payload loopback testing
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
Full bit error rate test (BERT)
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
• Encapsulations available only for DS1:
•
•
•
Multilink Frame Relay end-to-end (MLFR FRF.15)
Multilink PPP (MLPPP)
PPP over Frame Relay
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 SFPs:
• Multimode (model number: SFP-OC3-SR)
•
•
Intermediate Reach (IR-1) (model number: SFP-OC3-IR)
Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface support—See
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
LEDs
Alarms, errors, and events
One tricolor Status LED per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Loss of clock (LOC)
Loss of frame (LOF)
Loss of light (LOL)
Loss of pointer (LOP)
Loss of signal (LOS)
Payload label mismatch (PLM-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
Remote error indication (REI)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Virtual container—alarm indication signal (VAIS)
Virtual container—loss of clock (VLOC)
Virtual container—loss of pointer (VLOP)
Virtual container—mismatch (VMIS)
Virtual container—remote defect indication (VRD1)
Virtual container—unequipped (VUNEQ)
• SDH alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Higher order path—alarm indication signal (HP-AIS)
Higher order path—far-end receiver error (HP-FERF)
Higher order path—payload label mismatch (HP-PLM)
Higher order path—loss of pointer (HP-LOP)
Higher order path—remote defect indication (HP-RDI)
Higher order path—unequipped (HP-UNEQ)
Loss of clock (LOC)
Loss of frame (LOF)
Loss of light (LOL)
Loss of signal (LOS)
Multiplex section—alarm indication signal (MS-AIS)
Multiplex section—far-end receive error (MS-FERF)
Multiplex section—remote defect indication (MS-RDI)
Multiplex section—remote error indication (MS-REI)
Copyright © 2018, Juniper Networks, Inc.
41
M10i Multiservice Edge Router Interface Module Reference
•
•
•
•
•
•
•
•
•
Phase lock loop (PLL)
Remote error indication (REI)
Severely errored frame (SEF)
Tributary unit—alarm indication signal (TU-AIS)
Tributary unit—loss of clock (TU-LOC)
Tributary unit—loss of pointer (TU-LOP)
Tributary unit—mismatch (TU-MIS)
Tributary unit—remote defect indication (TU-RD1)
Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Remote alarm indication signal (RAIS)
• DS1 error detection:
•
•
•
•
•
•
•
•
•
Bursty errored seconds (BES)
CRC errors
Errored seconds (ES)
Line errored seconds (LES)
Loss of framing seconds (LOFS)
Loss of signal seconds (LOSS)
Severely errored seconds (SES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• DS3 alarms:
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Loss of signal (LOS)
Phase lock loop (PLL)
• DS3 error detection:
•
•
•
•
•
•
•
•
•
•
•
•
•
C-bit code violations (CCV)
C-bit errored seconds (CES)
C-bit severely errored framing seconds (CEFS)
CRC errors
Excessive zeros (EXZ)
Far-end block error (FEBE)
Far-end receive failure (FERF)
Line errored seconds (LES)
Parity bit (P-bit) code violations (PCV)
Parity bit (P-bit) errored seconds (PES)
Parity bit (P-bit) severely errored framing seconds (PSES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
42 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Related
Documentation
• M10i PICs Description
•
Channelized OC12/STM4 Enhanced IQ (IQE) PIC with SFP (M10i Router)
Figure 1: 1-Port IQE PIC
STM-4/OC-1
2 SFP
Software release
Description
Hardware features
• Junos OS Release 10.2 and later (Type 1)
•
•
•
•
•
•
•
One OC12/STM4 port
SONET channelization:
1 OC12 channel
4 OC3 channels
12 DS3 channels
336 DS1 channels
1011 DS0 channels
• SDH channelization:
•
•
•
•
•
•
•
1 STM4 channel
4 STM1 channels
12 E3 channels
252 E1 channels
12 DS3 channels
336 DS1 channels
1011 DS0 channels
• Power requirement: 0.64 A @ –48 V (30.7 W)
• Port is numbered 0.
Copyright © 2018, Juniper Networks, Inc.
43
M10i Multiservice Edge Router Interface Module Reference
Software features •
•
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
•
•
•
•
•
•
Subrate and scrambling:
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
•
•
•
•
•
Packet buffering, Layer 2 parsing
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support
Local line, remote line, and remote payload loopback testing
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
NOTE: BERT is not applicable for SONET/SDH channels.
• Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
• Encapsulations available only for DS1:
•
•
•
Multilink Frame Relay end-to-end (MLFR FRF.15)
Multilink PPP (MLPPP)
PPP over Frame Relay
44 Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx); single-mode fiber
SONET/SDH OC12/STM4 fiber-optic SFP transceivers:
•
•
•
Short reach (model number: SFP-OC12-SR)
Intermediate reach (IR-1) (model number: SFP-OC12-IR)
Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface Specifications” on page 16
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Loss of frame (LOF)
Loss of light (LOL)
Loss of pointer (LOP)
Loss of signal (LOS)
Payload label mismatch (PLM-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
Remote error indication (REI)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Virtual container—alarm indication signal (VAIS)
Virtual container—loss of pointer (VLOP)
Virtual container—mismatch (VMIS)
Virtual container—remote defect indication (VRD1)
Virtual container—unequipped (VUNEQ)
• SDH alarms:
•
•
•
•
•
•
•
•
•
•
•
•
Administrative unit alarm indication signal (AU-AIS)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Higher order path—alarm indication signal (HP-AIS)
Higher order path—far-end receive failure (HP-FERF)
Higher order path—payload label mismatch (HP-PLM)
Higher order path—loss of pointer (HP-LOP)
Higher order path—remote defect indication (HP-RDI)
Higher order path—unequipped (HP-UNEQ)
Loss of frame (LOF)
Loss of light (LOL)
Copyright © 2018, Juniper Networks, Inc.
45
M10i Multiservice Edge Router Interface Module Reference
46
•
•
•
•
•
•
•
•
•
•
•
•
•
Loss of signal (LOS)
Multiplex section—alarm indication signal (MS-AIS)
Multiplex section—far-end receive failure (MS-FERF)
Multiplex section—remote defect indication (MS-RDI)
Multiplex section—remote error indication (MS-REI)
Phase lock loop (PLL)
Remote error indication (REI)
Severely errored frame (SEF)
Tributary unit—alarm indication signal (TU-AIS)
Tributary unit—loss of pointer (TU-LOP)
Tributary unit—mismatch (TU-MIS)
Tributary unit—remote defect indication (TU-RD1)
Tributary unit—unequipped (TU-UNEQ)
• DS1 alarms:
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Remote alarm indication signal (RAIS)
• DS1 error detection:
•
•
•
•
•
•
•
•
Bursty errored seconds (BES)
CRC errors
Errored seconds (ES)
Line errored seconds (LES)
Loss of framing seconds (LOFS)
Severely errored seconds (SES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• DS3 alarms:
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Yellow alarm
• DS3 error detection:
•
•
•
•
•
•
•
•
•
•
•
•
•
C-bit code violations (CCV)
C-bit errored seconds (CES)
C-bit severely errored framing seconds (CEFS)
CRC errors
Excessive zeros (EXZ)
Far-end block error (FEBE)
Far-end receive failure (FERF)
Line errored seconds (LES)
Parity bit (P-bit) code violations (PCV)
Parity bit (P-bit) errored seconds (PES)
Parity bit (P-bit) severely errored framing seconds (PSES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
Copyright © 2018, Juniper Networks, Inc.
Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
Instrumentation
(counters)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
47
M10i Multiservice Edge Router Interface Module Reference
48 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 6
Circuit Emulation PIC Descriptions
•
Channelized OC3/STM1 Circuit Emulation PIC with SFP (M10I Router) on page 49
•
E1/T1 Circuit Emulation PIC (M10i Router) on page 52
Channelized OC3/STM1 Circuit Emulation PIC with SFP (M10I Router)
Software release
Description
Hardware features
• Junos OS Release 9.3 and later
•
•
•
Four OC3/STM1 ports
Power requirement: 0.52 A @ 48 V (25 W)
Channelization: DS1
Channelization down to E1/T1
Each port can be channelized as 84 T1 ports for a total of 336 T1 pseudowires or 63 E1 ports for a total of 252 pseudowires.
• Subrate and scrambling:
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
M13/C-bit parity encoding
Local and remote loopback testing
Copyright © 2018, Juniper Networks, Inc.
49
M10i Multiservice Edge Router Interface Module Reference
Software features
•
•
•
•
•
•
•
Loop timing
Optical diagnostics
AM1 or B8ZS line encoding
APS/SDH MSP
Fractional mode and framed clear channel mode
Superframe (D4/SF) and extended superframe (ESP) framing
•
•
•
Simple Network Management Protocol (SNMP):
OC3 MIB
T1 MIB
ATM MIB (Junos OS Release 10.2 and later)
•
•
•
•
Automatic protection switching (APS)
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
•
Encapsulations: Structure-agnostic time-division multiplexing (TDM) over packet (SAToP)
(RFC 4553)
Pseudowire emulation edge-to-edge (PWE3) for ATM (RFC 4717) (Junos OS Release 9.6 and later)
•
•
•
ATM Pseudowire emulation edge-to-edge via dynamic labels (LDP, RSVP-TE) (Junos OS
Release 9.6 and later)
Inverse mulitplexing (IMA) for ATM (Junos OS Release 10.0 and later)
•
•
•
•
•
•
•
•
ATM QoS (Junos OS Release 10.2 and later):
Per-virtual circuit (VC) and per-virtual path (VP) traffic shaping
Unspecified bit rate (UBR) traffic shaping
Fine-grained real-time variable bit rate (rtVBR) and real-time variable bit rate (nrtVBR) traffic shaping
Port-level egress shaping
Constant bit rate (CBR)
Policing on a per virtual circuit basis
Independent peak cell rate (PCR) and sustained cell rate (SCR) policing
Counting, tagging, or discard policing actions
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 SFPs:
•
•
Multimode (model number: SFP-OC3-SR)
Intermediate reach (IR-1) (model number: SFP-OC3-IR)
• Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
50 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Circuit Emulation PIC Descriptions
LEDs
Alarms, errors, and events
OK LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the router.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure.
APP LED, one bicolor:
•
•
Off—Monitoring application is not running.
Green—Monitoring application is running under acceptable load.
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
Structure agnostic alarms for T1 interface:
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Loss of signal (LOS)
Errored seconds (ES)
Line-errored seconds (LES)
Severely errored seconds (SES)
Unavailable errored seconds (UAS)
Bipolar violation (BPV)
Controlled slip (CS)
Line code violation (LCV)
Structure agnostic alarms for E1 interface:
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Loss of signal (LOS)
Errored seconds (ES)
Line-errored seconds (LES)
Severely errored seconds (SES)
Unavailable errored seconds (UAS)
Bipolar violation (BPV)
Controlled slip (CS)
Line code violation (LCV)
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
51
M10i Multiservice Edge Router Interface Module Reference
E1/T1 Circuit Emulation PIC (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 9.3 and later
• Configurable as either twelve E1 ports or twelve T1 ports
NOTE: Mixing E1 and T1 ports on the same PIC is not supported.
•
•
Power requirement: 0.52 A @ 48 V (25 W)
Onboard DSU functionality for E1 connectivity
•
•
•
•
Maximum transmission units (MTUs) of up to 1024 bytes
Per-interface diagnostics and loopback control
Per-interface alarm and event counting and detection
•
•
•
Framing
4-bit CRC for G.704 framed mode
G.704 without CRC4
Unframed
•
•
Balanced and unbalanced modes
Full bit error rate test (BERT)
52 Copyright © 2018, Juniper Networks, Inc.
Chapter 6: Circuit Emulation PIC Descriptions
Software features •
•
•
PIC can be configured as twelve T1 ports or twelve E1 ports
Local and remote loopback diagnostics
•
•
•
E1 ports
High-performance throughput on each port at speeds up to 2048 Mbps, full duplex
HDB3 line encoding
Integrated support for G.704 framed mode with CRC; this feature is user-configurable
NOTE: The G.704 implementation supports speeds slower than 2.048 Mbps; multiple channels within a single E1 interface are not supported.
•
•
•
•
•
G.704 framed without CRC4
Unframed
Framed clear channel mode
Unframed clear channel mode
Framed fractional mode
•
•
•
•
•
•
•
•
T1 ports
High-performance throughput on each port at speeds up to 1544 Mbps, full duplex
AMI and B8ZS line encoding
Framed clear channel mode
Fractional mode
Superframe (D4/SF) and extended superframe (ESF) framing
ESF CSU counters, WRT impairments, and CRC checking
Local DS1 line loopback, remote line loopback
•
•
•
•
•
•
•
•
Loop timing and PIC line timing
Encapsulations: Structure-agnostic time-division multiplexing (TDM) over packet (SAToP)
(RFC 4553)
Pseudowire emulation edge-to-edge (PWE3) for ATM (RFC 4717) (Junos OS Release 9.6 and later)
•
•
•
•
•
•
•
ATM Pseudowire emulation edge-to-edge via dynamic labels (LDP, RSVP-TE) (Junos OS
Release 9.6 and later)
Inverse mulitplexing (IMA) for ATM (Junos OS Release 10.0 and later)
Simple Network Management Protocol (SNMP): ATM MIB (Junos OS Release 10.2 and later)
ATM QoS (Junos OS Release 10.2 and later)
Per-virtual circuit (VC) and per-virtual path (VP) traffic shaping
Unspecified bit rate (UBR) traffic shaping
Fine-grained real-time variable bit rate (rtVBR) and real-time variable bit rate (nrtVBR) traffic shaping
Port-level egress shaping
Constant bit rate (CBR)
Policing on a per virtual circuit basis
Independent peak cell rate (PCR) and sustained cell rate (SCR) policing
Counting, tagging, or discard policing actions
Cables and connectors •
•
RJ-21 connector
Cables are rated for intra-building connections only.
Copyright © 2018, Juniper Networks, Inc.
53
M10i Multiservice Edge Router Interface Module Reference
LEDs OK LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the router.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure.
APP LED, one bicolor:
•
•
Off—Monitoring application is not running.
Green—Monitoring application is running under acceptable load.
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
54 Copyright © 2018, Juniper Networks, Inc.
Alarms, errors, and events
Structure agnostic alarms for T1:
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Loss of signal (LOS)
Errored seconds (ES)
Line code violation (LCV)
Line errored seconds (LES)
Severely errored seconds (SES)
Unavailable seconds (UAS)
Structure agnostic alarms for E1:
•
•
•
•
•
•
Alarm indication signal (AIS)
Errored seconds (ES)
Line code violation (LCV)
Line errored seconds (LES)
Severely errored seconds (SES)
Unavailable seconds (UAS)
Structure aware alarms for E1:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Loss of signal (LOS)
Yellow alarm (remote alarm indication (RAI) (YLW)
Far-end block error (FEBE)
Cylical Redundancy Check (CRC)
CRC major
CRC minor
Line code violation (LCV)
Path code violation (LCV)
Errored seconds (ES)
Bursty errored seconds (BES)
Line errored seconds (LES)
Severely errored seconds (SES)
Severely errored frame seconds (SEFS)
Unavailable seconds (UAS)
Related
Documentation
• M10i PICs Description
•
Chapter 6: Circuit Emulation PIC Descriptions
Copyright © 2018, Juniper Networks, Inc.
55
M10i Multiservice Edge Router Interface Module Reference
56 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 7
DS3, E1, E3, and T1 PIC Descriptions
•
DS3/E3 Enhanced IQ (IQE) PIC (M10i Router) on page 57
•
E1 PIC (M10i Router) on page 59
•
E3 IQ PIC (M10i Router) on page 61
DS3/E3 Enhanced IQ (IQE) PIC (M10i Router)
DS3/E3
TX
TX
TX
TX
PORT 0
RX
PORT 1
RX
PORT 2 RX
PORT 3
RX
Software release
Description
Hardware features
Software features
• Junos OS Release 10.2 and later
•
•
•
•
Four DS3 or E3 ports
DS3 or E3 is configurable on a per-port granularity
Power requirement: 0.51 A @ 48 V (24.7 W)
Model number: PB-4DS3-E3-IQE-BNC
• Ports are numbered 0 through 3 top to bottom
•
•
Maximum transmission units (MTUs) of up to 9192 bytes
Subrate and scrambling:
NOTE: Only DS3 interfaces support subrate and scrambling.
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink (subrate: only port A mode)
NOTE: For DS3 interfaces, Verilink does not function if an IQE interface is paired with an IQ interface.
• Data service unit (DSU) functionality
Copyright © 2018, Juniper Networks, Inc.
57
M10i Multiservice Edge Router Interface Module Reference
Cables and connectors • Standard DS3 BNC coaxial cable interfaces
LEDs
•
•
•
•
•
•
•
•
•
B3ZS line encoding
Framing: M13, C-bit parity, framed clear channel
Full bit error rate test (BERT)
ANSI T1.403 FDL
Internal and loop clocking
DS3 far end alarm and control (FEAC) channel
Local line, remote line, and remote playback loopback testing
Simple Network Management Protocol (SNMP): DS3 MIB
•
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Encapsulations:
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
58 Copyright © 2018, Juniper Networks, Inc.
Chapter 7: DS3, E1, E3, and T1 PIC Descriptions
Alarms, errors, and events
Instrumentation
(counters)
• DS3 alarms:
•
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Loss of signal (LOS)
Phase lock loop (PLL)
Yellow alarm
• DS3 error detection:
•
•
•
•
•
•
•
•
•
•
•
•
•
C-bit code violations (CCV)
C-bit errored seconds (CES)
C-bit severely errored framing seconds (CEFS)
CRC errors
Excessive zeros (EXZ)
Far-end block error (FEBE)
Far-end receive failure (FERF)
Line errored seconds (LES)
Parity bit (P-bit) code violations (PCV)
Parity bit (P-bit) errored seconds (PES)
Parity bit (P-bit) severely errored framing seconds (PSES)
Severely errored framing seconds (SEFS)
Unavailable seconds (UAS)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
E1 PIC (M10i Router)
Software release
Description
• Junos OS Release 6.0 and later
End-of-life (see notification PSN-2013-03-891 )
•
•
•
Four E1 or coaxial ports
4-port, 120-ohm, RJ-48
4-port, 75-ohm, coaxial
•
•
Power requirement: 0.08 A @ 48 V (3.74 W)
Onboard DSU functionality for E1 connectivity
Copyright © 2018, Juniper Networks, Inc.
59
M10i Multiservice Edge Router Interface Module Reference
Hardware features
Software features
•
•
•
•
•
•
•
•
•
•
•
High-performance throughput on each port at speeds up to 2.048 Mbps, full duplex
Maximum transmission units (MTUs) of up to 4500 bytes
Per-interface diagnostics and loopback control
Per-interface shaping on output
Per-interface alarm and event counting and detection
HDB3 line coding
4-bit CRC for G.704 framed mode
Per-port loop timing
Balanced and unbalanced modes
Packet buffering, Layer 2 parsing
Full bit error rate test (BERT)
• Integrated support for G.703 unframed mode and G.704 framed mode with CRC; this feature is user-configurable
NOTE: The G.704 implementation supports speeds slower than 2.048 Mbps; multiple channels within a single E1 interface are not supported.
•
•
•
•
•
•
Configurable clock source: Internal or loop
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
•
Two versions:
Four RJ-48 connectors (one per port)
Four coaxial connectors
• Custom 10-ft (3.05-m) posilock to BNC male cable, separate Rx and Tx
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Bipolar violations
Excessive zeros
Far-end block errors (FEBE, E-bit errors)
Loss of frame (LOF), Loss of signal (LOS)
Local and remote loopback diagnostics
Yellow alarm bit (X-bit) disagreements
Related
Documentation
• M10i PICs Description
•
60 Copyright © 2018, Juniper Networks, Inc.
Chapter 7: DS3, E1, E3, and T1 PIC Descriptions
E3 IQ PIC (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 6.1 and later
•
•
•
Four E3 ports
Power requirement: 0.38 A @ 48 V (18 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
•
•
•
•
Clear-channel (34.368-Mbps) and subrate E3
Unframed or ITU G.751 framing
Data service unit (DSU) functionality
•
•
Subrate and scrambling:
Digital Link/Quick Eagle
Kentrox
•
•
•
HDB3 line encoding
Full bit error rate test (BERT)
Local and remote loopback testing
•
•
•
•
•
•
• Quality of service (QoS) per port: weighted round-robin (WRR), random early detection (RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): E3 MIB, QoS MIB
Input policing and output shaping
Provider-side rate limiting
Full data link connection identifier (DLCI) range with sparse channel numbering
•
•
•
•
•
Per-DLCI queues with weighted deficit round-robin and strict priority
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors • Standard E3 BNC coaxial cable interfaces
Copyright © 2018, Juniper Networks, Inc.
61
M10i Multiservice Edge Router Interface Module Reference
LEDs
Alarms, errors, and events
Instrumentation
(counters)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Equipment failure (does not affect service)
Frame error
Line code violation
Loss of signal (LOS)
Out of frame (OOF)
Yellow alarm bit (A-bit) disagreements
• Layer 2 per-queue packet and byte counters
Related
Documentation
• M10i PICs Description
•
62 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 8
Ethernet PIC Descriptions
•
Fast Ethernet PICs (M10i Router) on page 63
•
Gigabit Ethernet PIC with SFP (M10i Router) on page 65
Fast Ethernet PICs (M10i Router)
Figure 2: 4-Port Fast Ethernet PIC Figure 3: 8-Port Fast Ethernet PIC
Figure 4: 12-Port Fast Ethernet PIC Figure 5: VHDCI to RJ-21 cable
Software release
•
•
•
•
PE-4FE-TX: Junos OS Release 6.0 and later
PE-8FE-FX: Junos OS Release 6.1 and later
End-of-life (see notification PSN-2013-03-891 )
PE-12FE-TX-MDI: Junos OS Release 6.0 and later
End-of-life (see notification PSN-2013-03-891 )
PE-12FE-TX-MDIX: Junos OS Release 6.0 and later
End-of-life (see notification PSN-2013-03-891 )
Copyright © 2018, Juniper Networks, Inc.
63
M10i Multiservice Edge Router Interface Module Reference
Description
Hardware features
•
•
•
•
•
4 or 12 100Base-TX ports; 8 100Base-FX ports
Power requirement:
4-port: 0.14 A @ 48 V (6.8 W)
8-port: 0.26 A @ 48 V (12.5 W)
12-port: 0.23 A @ 48 V (11 W)
•
•
•
•
•
High-performance throughput on each port at speeds up to 100 Mbps
Source and destination Media Access Control (MAC) address filtering
RMON EtherStats packet buffering
802.3 Ethernet standard compliant
•
•
4-port PICs support:
MTUs of up to 9192 bytes
1024 802.1Q VLANs per port
•
•
•
8-port and 12-port PICs support
MTUs of up to 1532 bytes
16 802.1Q VLANs per port
Software features
•
•
•
•
Autosensing full-duplex and half-duplex modes
Virtual Router Redundancy Protocol (VRRP)
802.1q virtual LANs (VLANs)
Circuit cross-connect (CCC) VLAN
Cables and connectors 4-port PIC:
• Connector: Two-pair, Category 5 unshielded twisted-pair connectivity through an RJ-45 connector
• Pinout: MDI noncrossover
8–port PIC:
• Connector: MT-RJ female
FX optical interface-see
“Fast Ethernet 100BASE-FX Optical Interface Specifications” on page 13
12-port PIC:
• Connector: One very high density connector interface (VHDCI) to RJ-21 cable that connects to an RJ-45 patch panel
64 Copyright © 2018, Juniper Networks, Inc.
Chapter 8: Ethernet PIC Descriptions
LEDs Status LED, one bicolor:
•
•
•
Off—PIC ports not enabled.
Green—PIC is operating normally.
Red—PIC has an error or failure.
4-port PIC—One pair of port LEDs:
•
•
Link LED—If green, the port is online; if there is no light, the port is down.
RX LED—If flashing green, the port is receiving data; if there is no light, the port might be on but is not receiving data.
8-port PIC—One pair of port LEDs per port:
• Port link LED—If green, the port is online; if there is no light, the port is down
NOTE: The Link LED remains lit on the 8-port PIC when the port is down.
• Port RX LED—If flashing green, the port is receiving data; if there is no light, the port might be on, but is not receiving data
12-port PIC—One port LED per port:
•
•
•
•
•
Green—100-Mbps link established
Flashing green—100-Mbps activity
Yellow—10-Mbps link established
Flashing yellow—10-Mbps activity
Off—No link present
NOTE: The port LEDs remain lit on the 12-port PIC when the ports are down.
Related
Documentation
• M10i PICs Description
•
Gigabit Ethernet PIC with SFP (M10i Router)
Software release
Description
• Junos OS Release 6.3 and later
For information on which CFEBs support this PIC, see “M10i PIC/CFEB Compatibility” on page 8 .
•
•
•
One Gigabit Ethernet port
Power requirement: 0.15 A @ 48 V (7.3 W)
Supports large Ethernet frame sizes for more efficient throughput across the intra-POP network
Copyright © 2018, Juniper Networks, Inc.
65
M10i Multiservice Edge Router Interface Module Reference
Hardware features
Software features
•
•
•
•
High-performance throughput on each port at speeds up to 1 Gbps
Autonegotiation between Gigabit Ethernet circuit partners
Full-duplex mode
Maximum transmission units (MTUs) of up to 9192 bytes
•
•
•
•
•
•
•
Virtual Router Redundancy Protocol (VRRP) support
802.1q virtual LANs (VLANs) support
960 destination MAC filters per port
Flexible Ethernet encapsulation
Multiple tag protocol identifiers (TPID) support
Source MAC learning
MAC accounting and policing—Dynamic local address learning of source MAC addresses
Cables and connectors •
•
You can install any transceiver supported by the PIC.
Fiber-optic SFP transceivers:
• Duplex LC/PC connector (Rx and Tx)
NOTE: Do not install Gigabit Ethernet SFPs in the SONET/SDH port. The port will not recognize the SFP.
LEDs Status LED, one bicolor:
•
•
•
Off—PIC is not enabled.
Green—PIC is operating normally.
Red—PIC has an error or failure.
Port LEDs, one pair per port:
•
•
Link—If green, the port is online; if there is no light, the port is down.
Activity—If flashing green, the port is receiving data; if there is no light, the port might be on but is not receiving data.
Related
Documentation
• M10i PICs Description
•
66 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 9
Ethernet Enhanced IQ2 (IQ2E) PIC
Descriptions
•
Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (M10i Router) on page 67
Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 9.4 and later
•
•
Four Gigabit Ethernet ports
Power requirement: 0.67 A @ 48 V (32 W)
• High-performance throughput on each port: speeds up to 1 Gbps
•
•
Full-duplex mode
Large maximum transmission units (MTUs) of up to 9192 bytes
Copyright © 2018, Juniper Networks, Inc.
67
M10i Multiservice Edge Router Interface Module Reference
Software features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Intelligent handling of oversubscribed traffic
Optical diagnostics and related alarms
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Drop statistics reported per queue for each of four priority-based drop profiles
Four levels of strict priorities with priority propagation among scheduling levels
Virtual Router Redundancy Protocol (VRRP) support
Hierarchical shaping and hierarchical scheduler
Fine-grained queuing and shaping per logical interface at both ingress and egress
802.1q virtual LANs (VLANs)
VLAN stacking and rewriting
Channels defined by two stacked VLAN tags
Multiple tag protocol identifiers (TPID) support
IP service for nonstandard TPID and stacked VLAN tags
802.1p rewrite per channel
Flexible mapping of channels and scheduler resources at both ingress and egress
16,000 schedulers (2,000 schedulers with 8 queues each or 4,000 schedulers with 4 queues each)
•
•
•
Scheduler resources dynamically allocated across ports
Flexible Ethernet encapsulation
MAC learning, policing, accounting, and filtering
Cables and connectors
•
•
• You can install any transceiver supported by the PIC. For information about installing and removing transceivers, see the hardware guide for your router.
•
•
•
•
Duplex LC/PC connector (Rx and Tx)
Fiber-optic small form-factor pluggable transceivers (SFPs):
1000Base-LH (model number: SFP-1GE-LH)
1000Base-LX (model number: SFP-1GE-LX)
1000Base-SX (model number: SFP-1GE-SX)
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• Copper small form-factor pluggable transceivers (SFPs):1000Base-T (model number:
SFP-1GE-T). Copper interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
NOTE: Do not install SONET/SDH SFPs in the Gigabit Ethernet port. The port will not recognize the SFP.
68 Copyright © 2018, Juniper Networks, Inc.
Chapter 9: Ethernet Enhanced IQ2 (IQ2E) PIC Descriptions
LEDs OK LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the router.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure.
APP LED, one bicolor:
•
•
Off—Monitoring application is not running.
Green—Monitoring application is running under acceptable load.
Port LEDs, one per port:
•
•
Off—Port is not enabled.
Green—Port is online with no alarms or failures.
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
69
M10i Multiservice Edge Router Interface Module Reference
70 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 10
Services PIC Descriptions
•
Multiservices 100 PIC (M10i Router) on page 71
•
Tunnel Services PIC (M10i Router) on page 73
Multiservices 100 PIC (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 8.1 and later
•
•
•
Supports tunnel services. This feature is included with the PIC and does not require an individual license.
Individual licenses must be purchased for additional services.
Power requirement: 0.52 A @ 48 V (25 W)
• Active monitoring on up to 1.6 million flows
•
•
Support for up to 2000 service sets
Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
Depending on your Junos OS Release and individual licenses, software features for this PIC can include the features listed in
Table 22 on page 72 . For more information about the software
features available for services PICs, see the Junos OS Services Interfaces Library for Routing Devices .
Copyright © 2018, Juniper Networks, Inc.
71
M10i Multiservice Edge Router Interface Module Reference
LEDs Status LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the chassis.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure and no further harm can be done by removing it from the chassis.
Application LED, one bicolor:
•
•
•
Off—Service is not running.
Green—Service is running under acceptable load.
Yellow—Service is overloaded.
Table 22: Multiservices PICs Software Features Supported by the M10i Router
Software Feature Multiservices 100
GRE Key
GRE dont-fragment
8.1
8.1
Stateful firewall with packet inspection: detects SYN attacks, ICMP and UDP floods, and ping of death attacks
8.1
Network Address Translation (NAT) for IP addresses
Port Address Translation (PAT) for port numbers
8.1
8.1
IP Security (IPSec) encryption
Active flow monitoring exports cflowd version 5 and version 8 records
Active flow monitoring exports flow monitoring version 9 records, based on RFC 3954
Passive flow monitoring
Passive flow collection
Flow-tap
Dynamic flow capture
RPM
Link services
Tunnel services:
•
•
•
IP-IP unicast tunneling
GRE unicast tunneling—Supports GRE fragmentation
Protocol Independent Multicast (PIM) sparse mode unicast tunneling
8.2
–
8.2
8.1
8.1
8.1
8.1
8.3
–
–
72 Copyright © 2018, Juniper Networks, Inc.
Chapter 10: Services PIC Descriptions
Table 22: Multiservices PICs Software Features Supported by the M10i Router (continued)
Software Feature Multiservices 100
Virtual tunnel interface for Layer 3 VPNs
Layer 2 Tunneling Protocol (L2TP)
Voice services:
• Compressed Real-Time Transport Protocol (CRTP)
Encapsulations:
•
•
Multilink Frame Relay (MLFR)
Multilink Point-to-Point Protocol (MLPP)
8.1
8.2
8.1
8.1
Related
Documentation
• M10i PICs Description
•
Tunnel Services PIC (M10i Router)
Software release
Description
Hardware features
Software features
LEDs
• Junos OS Release 6.0 and later
• Power requirement: 0.07 A @ 48 V (3.4 W)
•
•
Loopback function that encapsulates and de-encapsulates packets
SONET/SDH OC12/STM4 tunneling bandwidth
For a list of the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices .
•
•
•
IP-IP unicast tunneling
GRE unicast tunneling
PIM sparse mode unicast tunneling
One tricolor:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
Copyright © 2018, Juniper Networks, Inc.
73
M10i Multiservice Edge Router Interface Module Reference
Related
Documentation
• M10i PICs Description
•
74 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 11
Serial PIC Descriptions
•
EIA-530 PIC (M10i Router) on page 75
EIA-530 PIC (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 6.0 and later
•
•
Two EIA-530, X.21 or V.35 serial ports
Power requirement: 0.07 A @ 48 V (3.4 W)
•
•
•
•
Configured as data terminal equipment (DTE) ports
Resynchronization signal
Receives clock rates up to 16 Mbps
Local, data communications equipment (DCE) local, and DTE remote loopbacks
Copyright © 2018, Juniper Networks, Inc.
75
M10i Multiservice Edge Router Interface Module Reference
76
Software features •
•
•
Supports four queues per port
Random early detection (RED)
•
•
•
•
•
•
•
•
Transmitter Signal Element Timing is looped from the timing received on the Transmitted
Signal Element DCE. EIA-530 ports support the ability to invert the Transmit Data Element.
The EIA-530 ports support the following rates:
2.048 Mbps
2.341 Mbps
2.731 Mbps
3.277 Mbps
4.09 Mbps
5.461 Mbps
8.192 Mbps
16.384 Mbps
•
•
•
V.35 ports support up to 2.048 Mbps
X.21 ports support up to 10 Mbps
•
•
•
•
•
Encapsulations
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
•
Two DB-25 male connectors (one per port, included with PIC)
V.35 requires an EIA-530 to V.35 cable and connects to a V.35 DTE 34-pin Winchester type male cable (one per port)
X.21 requires an EIA-530 to X.21 cable and connects to a X.21 DTE DB-15 male cable
LEDs Three bicolor per port:
• Data set ready (DSR):
•
•
Green—DSR is detected or ignored
Red—DSR expected but not present
• Data carrier detect (DCD):
•
•
Green—DCD is detected or ignored
Red—DCD expected but not present
•
•
•
Resynchronization:
Green—Keepalives are being received
Red—Data terminal ready (DTR) toggled from low to high (resynchronization pulses are being sent)
Instrumentation
(counters)
•
•
•
•
Per-port packet and byte counters
Resynchronization counters:
Number of resynchronizations initiated
Time of last resynchronization
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
CHAPTER 12
SONET/SDH PIC Descriptions
•
SONET/SDH OC3/STM1 PIC with SFP (M10i Router) on page 77
•
SONET/SDH OC3/STM1 Enhanced IQ (IQE) PIC with SFP (M10i Router) on page 80
•
SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP (M10i Router) on page 82
•
SONET/SDH OC12/STM4 (Multi-Rate) PIC with SFP (M10i Router) on page 85
SONET/SDH OC3/STM1 PIC with SFP (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 8.4 and later
•
•
Two OC3c ports
Power requirement: 0.25 A @ 48 V (12 W)
•
•
•
•
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
Copyright © 2018, Juniper Networks, Inc.
77
M10i Multiservice Edge Router Interface Module Reference
Software features
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
• Multimode (model number: SFP-OC3-SR)
•
•
Intermediate reach (IR-1) (model number: SFP-OC3-IR)
Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the CLI Explorer .
LEDs
•
•
•
•
•
•
•
Optical diagnostics and related alarms
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
•
•
•
•
•
Encapsulations
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
78 Copyright © 2018, Juniper Networks, Inc.
Chapter 12: SONET/SDH PIC Descriptions
Alarms, errors, and events
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SONET alarms:
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
79
M10i Multiservice Edge Router Interface Module Reference
SONET/SDH OC3/STM1 Enhanced IQ (IQE) PIC with SFP (M10i Router)
STM-1/OC-
3 SFP
80
Software release
Description
Hardware features
Software features
• Junos OS Release 10.2 and later (Type 1)
•
•
•
•
Four OC3 or STM1 ports
SONET or SDH is configurable on a per-port granularity
Power requirement: 0.6 A @ 48 V (28.8 W)
Model number: PB-4OC3-STM1-IQE-SFP
•
•
Top row: Ports are numbered 0 and 1 from left to right
Bottom row: Ports are numbered 2 and 3 from left to right
•
•
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
•
•
•
•
Packet buffering, Layer 2 parsing
Local line and remote payload loopback testing
Simple Network Management Protocol (SNMP): OC3 MIB
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
Copyright © 2018, Juniper Networks, Inc.
Chapter 12: SONET/SDH PIC Descriptions
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 fiber-optic SFP transceivers:
•
•
•
Multimode (model number: SFP-OC3-SR)
Intermediate reach (IR-1) (model number: SFP-OC3-IR)
Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
LEDs
Alarms, errors, and events
One tricolor Status LED per port:
•
•
•
•
Off—Not enabled.
Green—Online with no alarms or failures.
Yellow—Online with alarms for remote failures.
Red—Active with a local alarm; router has detected a failure.
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Loss of frame (LOF)
Loss of light (LOL)
Loss of pointer (LOP)
Loss of signal (LOS)
Payload label mismatch (PLM-P)
Phase lock loop (PLL)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
Remote error indication (REI)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Severely errored frames (SEF)
• SDH alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Higher order path—alarm indication signal (HP-AIS)
Higher order path—far-end receive failure (HP-FERF)
Higher order path—payload label mismatch (HP-PLM)
Higher order path—loss of pointer (HP-LOP)
Higher order path—remote defect indication (HP-RDI)
Higher order path—unequipped (HP-UNEQ)
Loss of frame (LOF)
Loss of light (LOL)
Loss of signal (LOS)
Multiplex section—alarm indication signal (MS-AIS)
Multiplex section—far-end receive failure (MS-FERF)
Copyright © 2018, Juniper Networks, Inc.
81
M10i Multiservice Edge Router Interface Module Reference
•
•
•
•
•
Multiplex section—remote defect indication (MS-RDI)
Multiplex section—remote error indication (MS-REI)
Phase lock loop (PLL)
Remote error indication (REI)
Severely errored frames (SEF)
• Error detection:
•
•
•
•
Errored seconds (ES-S, ES-L, ES-P)
Severely errored framing seconds (SEFS-S)
Severely errored seconds (SES-S, SES-L, SES-P)
Unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 8.4 and later
• Rate-selectable using one of the following rates:
•
•
•
1-port OC12/STM4
1-port OC12c/STM4c
4-port OC3c/STM1c
• Power requirement: 0.40 A @ 48 V (19 W)
•
•
•
•
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
82 Copyright © 2018, Juniper Networks, Inc.
Chapter 12: SONET/SDH PIC Descriptions
Software features
•
•
•
•
•
•
•
Optical diagnostics and related alarms
Per-port SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors You can install any transceiver supported by the PIC.
•
•
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
•
•
•
Multimode (model number: SFP-OC3-SR)
Intermediate reach (IR-1) (model number: SFP-OC3-IR)
Long reach (LR-1) (model number: SFP-OC3-LR)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
SONET/SDH OC12/STM4 small form-factor pluggable (SFP) transceivers:
•
•
•
Short reach (SR-1)
Intermediate reach (IR-1)
Long reach (LR-1)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface Specifications” on page 16
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the CLI Explorer .
LEDs One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
Copyright © 2018, Juniper Networks, Inc.
83
M10i Multiservice Edge Router Interface Module Reference
Alarms, errors, and events
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SONET alarms:
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
84 Copyright © 2018, Juniper Networks, Inc.
Chapter 12: SONET/SDH PIC Descriptions
SONET/SDH OC12/STM4 (Multi-Rate) PIC with SFP (M10i Router)
Software release
Description
Hardware features
Software features
• JUNOS 8.4 and later
•
•
•
•
Rate-selectable using one of the following rates:
1-port OC3
1-port OC12
1-port OC12c
• Power requirement: 0.20 A @ 48 V (9.5 W)
•
•
•
•
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
•
•
•
•
•
•
•
Optical diagnostics and related alarms
Per-port SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Copyright © 2018, Juniper Networks, Inc.
85
M10i Multiservice Edge Router Interface Module Reference
Cables and connectors You can install any transceiver supported by the PIC. For information about installing and removing transceivers, see the hardware guide for your router.
•
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
•
•
Multimode
Intermediate reach (IR-1)
• Long reach (LR-1)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
•
•
•
•
SONET/SDH OC12/STM4 small form-factor pluggable (SFP) transceivers:
Short reach (SR-1)
Intermediate reach (IR-1)
Long reach (LR-1)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface Specifications” on page 16
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the CLI Explorer .
LEDs One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
86 Copyright © 2018, Juniper Networks, Inc.
Chapter 12: SONET/SDH PIC Descriptions
Alarms, errors, and events
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SONET alarms:
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
•
M10i PIC/CFEB Compatibility on page 8
Copyright © 2018, Juniper Networks, Inc.
87
M10i Multiservice Edge Router Interface Module Reference
88 Copyright © 2018, Juniper Networks, Inc.
CHAPTER 13
End-of-Life PIC Descriptions
•
ATM DS3 EOL PIC (M10i Router) on page 90
•
ATM E3 EOL PIC (M10i Router) on page 91
•
ATM2 E3 IQ EOL PIC (M10i Router) on page 93
•
Multichannel DS3 EOL PIC (M10i Router) on page 94
•
Channelized DS3 IQ EOL PIC (M10i Router) on page 96
•
Channelized E1 IQ EOL PIC (M10i Router) on page 97
•
Channelized OC3 IQ EOL PIC (M10i Router) on page 99
•
Channelized OC12 IQ EOL PIC (M10i Router) on page 100
•
Channelized STM1 IQ EOL PIC (M10i Router) on page 102
•
Channelized T1 IQ EOL PIC (M10i Router) on page 104
•
DS3 EOL PIC (M10i Router) on page 106
•
E3 PIC (M10i Router) on page 107
•
T1 EOL PIC (M10i Router) on page 109
•
Gigabit Ethernet EOL PIC (M10i Router) on page 110
•
Gigabit Ethernet IQ EOL PIC with SFP (M10i Router) on page 111
•
Gigabit Ethernet IQ2 EOL PIC with SFP (M10i Router) on page 112
•
Adaptive Services EOL PIC (M10i Router) on page 114
•
Adaptive Services II EOL PIC (M10i Router) on page 116
•
Adaptive Services II Layer 2 Services EOL PIC (M10i Router) on page 118
•
Adaptive Services II FIPS EOL PIC (M10i Router) on page 120
•
ES EOL PIC (M10i Router) on page 122
•
Link Services EOL PIC (M10i Router) on page 123
•
Monitoring Services EOL PIC (M10i Router) on page 124
•
SONET/SDH OC3c/STM1 EOL PIC (M10i Router) on page 125
•
SONET/SDH OC12c/STM4 EOL PIC (M10i Router) on page 127
•
SONET/SDH OC12/STM4 Enhanced IQ (IQE) EOL PIC with SFP (M10i
•
SONET/SDH OC48c/STM16 EOL PIC with SFP on page 132
Copyright © 2018, Juniper Networks, Inc.
89
M10i Multiservice Edge Router Interface Module Reference
ATM DS3 EOL PIC (M10i Router)
90
Software release
Description
Hardware features
•
•
Junos OS Release 6.1 and later
End-of-life (see notification PSN-2003-10-018 )
•
•
•
•
•
•
•
Four DS3 ports
Power requirement: 0.39 A @ 48 V (19 W)
Conforms to ANSI T1.105-1991 and T1E1.2/93-020R1
Asynchronous Transfer Mode (ATM) standards compliant
Alarm and event counting and detection
Compatible with well-known ATM switches
ATM switch ID, which displays the switch IP address and local interface name of the adjacent
Fore ATM switches
•
•
•
•
• OAM fault management processes alarm indication signal (AIS) and remote defect indicator
(RDI) cells
ASIC-based packet segmentation and reassembly (SAR) management and output port queuing
16-MB SDRAM memory for ATM SAR
•
•
•
•
Packet buffering, Layer 2 parsing
Configurable framing options:
C-bit with ATM direct mapping
C-bit with PLCP framing (default)
M23 ATM direct mapping
M23 with PLCP framing
Software features • Multiprotocol Label Switching (MPLS) circuit cross-connect (CCC) for leveraging ATM access networks
Support for user-configurable virtual circuits (VC) and virtual paths (VP) •
• ATM Inverse Address Resolution Protocol (ARP), which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit (PVC)
Unspecified bit rate (UBR) traffic shaping
•
•
•
• Fine-grained variable bit rate (VBR) traffic shaping
Outbound PIC queues cells on a per-VC basis
Encapsulations—AAL5 subnetwork attachment point (SNAP)
Cables and connectors •
•
10-ft (3.05-m) posilock SMB to BNC
Four pairs of RX and TX coaxial cables
Copyright © 2018, Juniper Networks, Inc.
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Far-end block error (FEBE)
Frame error
Idle code
Idle received
Local and remote loopback
Loss of signal (LOS)
Out of frame (OOF)
Path parity error
Yellow alarm
Related
Documentation
• M10i PICs Description
ATM E3 EOL PIC (M10i Router)
Chapter 13: End-of-Life PIC Descriptions
Software release
Description
• Junos OS Release 6.1 and later
End-of-life (see notification PSN-2003-10-018 )
•
•
•
•
•
•
•
Four E3 ports
Power requirement: 0.43 A @ 48 V (20.8 W)
Conforms to ANSI T1.105-1991 and T1E1.2/93-020R1
Asynchronous Transfer Mode (ATM) standards compliant
Alarm and event counting and detection
Compatible with well-known ATM switches
ATM switch ID, which displays the switch IP address and local interface name of the adjacent
Fore ATM switches
Copyright © 2018, Juniper Networks, Inc.
91
M10i Multiservice Edge Router Interface Module Reference
Hardware features • OAM fault management processes alarm indication signal (AIS) and remote defect indicator
(RDI) cells
ASIC-based packet segmentation and reassembly (SAR) management and output port queuing •
•
•
•
16-MB SDRAM memory for ATM SAR
Packet buffering, Layer 2 parsing
•
•
•
Configurable framing options:
G.751 direct mapping
G.751 with PLCP encapsulation (default)
G.832 ATM direct mapping
Software features
Cables and connectors •
•
10-ft (3.05-m) posilock SMB to BNC
Four pairs of RX and TX coaxial cables
LEDs
•
•
•
•
•
•
• Multiprotocol Label Switching (MPLS) circuit cross-connect (CCC) for leveraging ATM access networks
Support for user-configurable virtual circuits (VC) and virtual paths (VP)
ATM Inverse Address Resolution Protocol (ARP), which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit (PVC)
Unspecified bit rate (UBR) traffic shaping
Fine-grained variable bit rate (VBR) traffic shaping
Outbound PIC queues cells on a per-VC basis
Encapsulations—AAL5 subnetwork attachment point (SNAP)
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Frame Error
Line code violation
Local and remote loopback
Loss of signal (LOS)
Out of fFrame (OOF)
Yellow alarm
Related
Documentation
• M10i PICs Description
92 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
ATM2 E3 IQ EOL PIC (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 6.1 and later
End-of-life (see notification PSN-2013-03-891 )
•
•
•
•
Two E3 ports
Power requirement: 0.41 A @ 48 V (20 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
ATM standards compliant
•
•
•
16-MB SDRAM memory for ATM segmentation and reassembly (SAR)
•
•
•
ATM switch ID
Configurable framing options:
G.751 direct mapping
G.751 with PLCP encapsulation (default)
G.832 ATM direct mapping
• Internal and loop timing
•
•
•
•
•
Per-virtual circuit (VC) and per-virtual path (VP) traffic shaping
Unspecified bit rate (UBR) traffic shaping
Fine-grained variable bit rate (VBR) traffic shaping
Circuit cross-connect (CCC)
•
ATM Inverse Address Resolution Protocol (ARP), which enables routers to automatically learn the IP address of the router on the far end of an ATM permanent virtual circuit (PVC)
Simple Network Management Protocol (SNMP):
•
•
•
Management Information Base (MIB) 2 (RFC 1213)
ATM MIB (RFC 1695)
SONET MIB
•
•
•
•
•
•
AAL5 encapsulations:
ATM-VC-MUX
ATM-NLPID
ATM-Cisco-LLPID
ATM-SNAP
ATM-CCC-VC-MUX
Copyright © 2018, Juniper Networks, Inc.
93
M10i Multiservice Edge Router Interface Module Reference
Cables and connectors •
•
•
10 ft (3.05 m) posilock SMB to BNC (provided)
Four pairs of Rx and Tx coaxial cables
•
•
SONET/SDH OC3/STM1 fixed transceiver:
Multimode
Intermediate reach (IR-1)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Frame error
Line code violation
Local and remote loopback
Loss of signal (LOS)
Out of frame (OOF)
Yellow alarm
Related
Documentation
• M10i PICs Description
•
Multichannel DS3 EOL PIC (M10i Router)
94
Software release
Description
Hardware features
• Junos OS Release 6.1 and later
End-of-life (see notification PSN-2004-10-026 )
•
•
•
Two DS3 ports
Power requirement: 0.31 A @ 48 V (14.9 W)
Supports up to 128 logical customer channels per DS3 port
•
•
Support for N xT1 by interoperating with the Link Services and Multilink Services PICs, using
MLPPP and MLFR protocols
Onboard DSU functionality
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Software features
Cables and connectors • Custom 10 ft/3.05 m posilock to BNC male cable, separate Rx and Tx
LEDs
•
•
•
•
•
•
•
Support for four data-link connection identifiers (DLCIs) per logical customer channel
DS3 alarm and event counting
DS3 alarm and event detection
DS3 diagnostics and loopback control
DS3 framing: M13, C-bit
T1 framing: super frame (SF) and extended super frame (ESF)
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Point-to-Point Protocol (PPP)
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
•
•
•
Far-end block error (FEBE)
Parity bit (P-bit) disagreements
Path priority error
Alarm indication signal (AIS)
Loss of signal (LOS)
Out of frame (OOF)
Yellow alarm
AIS received
Simultaneous BERT functionality
Idle received
Local and remote loopback
Related
Documentation
• M10i PICs Description
Copyright © 2018, Juniper Networks, Inc.
95
M10i Multiservice Edge Router Interface Module Reference
Channelized DS3 IQ EOL PIC (M10i Router)
96
Software release
Description
Hardware features
Software features
• Junos OS Release 6.0 and later
End-of-life (see notification PSN-2013-03-892 )
•
•
•
•
Four DS3 ports
Power requirement: 0.32 A @ 48 V (15.6 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
Channelization: DS3, DS0
•
•
Data service unit (DSU) functionality
•
•
•
•
•
Subrate and scrambling:
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
•
•
B3ZS line encoding
M13 or C-bit parity
Full bit error rate test (BERT)
Local and remote loopback testing
•
•
•
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): DS1 MIB, DS3 MIB
Dynamic, arbitrary channel configuration
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors • Standard DS3 BNC coaxial cable interfaces
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
LEDs
Alarms, errors, and events
Instrumentation
(counters)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Excessive zeros (EXZ)
Far-end block error (FEBE)
Frame error
Idle code, Idle received
Line code violation (LCV)
Loss of signal (LOS)
Out of frame (OOF)
Parity bit (P-bit) disagreements
Path parity error
Yellow alarm bit (X-bit) disagreements
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
Channelized E1 IQ EOL PIC (M10i Router)
Software release
Description
•
• 10-port: PE-10CHE1-RJ48-QPP-N: Junos OS Release 9.1R4, 9.2R3, 9.3 and later
End-of-life (see notification PSN-2013-03-892 )
10-port: PE-10CHE1-RJ48-QPP: Junos OS Release 6.0 and later
End-of-life (see notification PSN-2008-10-038 )
•
•
•
•
Ten E1 ports
Power requirement: 0.15 A @ 48 V (7.2 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface.
Channelization: E1, DS0
Copyright © 2018, Juniper Networks, Inc.
97
M10i Multiservice Edge Router Interface Module Reference
Hardware features
Software features
•
•
•
•
•
•
Data service unit (DSU) functionality
Ports configurable as clear channel E1 interfaces with 2.048-Mbps connectivity
Supports unframed E1 G.703 and G.704 framing modes
Supports HDB3 line coding
CRC4 configurable
Local and remote loopback testing
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): E1 MIB, DS0 MIB
•
•
•
• Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors • 120-ohm RJ-48C
LEDs
Alarms, errors, and events
Instrumentation
(counters)
One bicolor per E1 port:
•
•
•
Off—Port not enabled
Green—Physical E1 link is up; individual subchannels can be down
Red—Physical E1 link is down
•
•
•
•
Alarm indication signal (AIS)
Loss of frame (LOF)
Out of frame (OOF)
Failed signal rate (FSR)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
98 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Channelized OC3 IQ EOL PIC (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 7.6 and later
End-of-life (see notification PSN-2013-03-892 )
•
•
•
•
One OC3 port
Power requirement: 0.39 A @ 48 V (18.6 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
Channelization: DS3, DS1, DS0
• Subrate and scrambling:
•
•
•
•
•
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
•
•
Packet buffering, Layer 2 parsing
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support
Local and remote loopback testing
•
•
•
•
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
Dynamic, arbitrary channel configuration
•
•
•
•
•
Full bit error rate test (BERT)
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
Duplex SC/PC connector (Rx and Tx); single-mode fiber intermediate-reach fiber
SONET/SDH OC3/STM1 fixed transceivers:
• Intermediate reach (IR-1)
Optical interface specifications—see
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
Copyright © 2018, Juniper Networks, Inc.
99
M10i Multiservice Edge Router Interface Module Reference
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), Far-end block error (FEBE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds
(SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Frame error
•
•
•
•
•
•
•
•
• Idle code, Idle received
Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Out of frame (OOF)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Parity bit (P-bit) disagreements
Path parity error
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
• Yellow alarm bit (X-bit) disagreements
Related
Documentation
• M10i PICs Description
•
Channelized OC12 IQ EOL PIC (M10i Router)
100
Software release
Description
• Junos OS Release 6.1 and later
End-of-life (see notification PSN-2013-03-892 )
•
•
•
•
One OC12 port
Power requirement: 0.23 A @ 48 V (10.8 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
Channelization: OC3, DS3, DS1, DS0
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Hardware features
Software features
•
•
•
•
•
•
Subrate and scrambling:
Digital Link/Quick Eagle
Kentrox
Larscom
ADTRAN
Verilink
•
•
•
•
Packet buffering, Layer 2 parsing
M13/C-bit parity encoding
DS3 far-end alarm and control (FEAC) channel support
Local and remote loopback testing
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Simple Network Management Protocol (SNMP): OC3 MIB, DS3 MIB, T1 MIB
•
•
•
• Dynamic, arbitrary channel configuration
Full bit error rate test (BERT)
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
Duplex SC/PC connector (Rx and Tx); single-mode fiber
SONET/SDH OC12/STM4 fixed transceivers:
• Intermediate reach (IR-1)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface Specifications” on page 16
LEDs One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
Copyright © 2018, Juniper Networks, Inc.
101
M10i Multiservice Edge Router Interface Module Reference
Alarms, errors, and events
Instrumentation
(counters)
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), far-end block error (FEBE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds
(SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
•
•
•
•
•
•
•
•
•
Frame error
Idle code, Idle received
Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Out of frame (OOF)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Parity bit (P-bit) disagreements
Path parity error
Remote defect indication (RDI-L, RDI-P)
•
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Yellow alarm bit (X-bit) disagreements
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
Channelized STM1 IQ EOL PIC (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 6.0 and later
End-of-life (see notification PSN-2013-03-892 )
•
•
•
•
One STM1 port
Power requirement: 0.39 A @ 48 V (18.6 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface
Channelization: STM1c, fractional E1, framed and unframed DS0
•
•
Packet buffering, Layer 2 parsing
Local and remote loopback testing
102 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Software features
Cables and connectors • Duplex SC/PC connector (Rx and Tx); single-mode intermediate-reach fiber
LEDs
•
•
•
•
•
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
SNMP: SONET/SDH MIB, T1/E1 MIB
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT) patterns at E1 and DS0 levels
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Alarms, errors, and events
Instrumentation
(counters)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
Alarm indication signal (AIS-L, AIS-P)
Bit error rate signal degrade (BERR-SD), bit error rate signal fail (BERR-SF)
Bit interleaved parity errors B1, B2, B3 (CV-S, CV-L, CV-P)
Errored seconds (ES-S, ES-L, ES-P), far-end bit errors REI-L, REI-P (CV-LFE, CV-PFE), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
Loss of frame (LOF), loss of pointer (LOP-P), loss of signal (LOS)
Payload mismatch (PLM-P), payload unequipped (UNEQ-P)
Remote defect indication (RDI-L, RDI-P)
Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
103
M10i Multiservice Edge Router Interface Module Reference
Channelized T1 IQ EOL PIC (M10i Router)
Software release
Description
Hardware features
• Junos OS Release 7.4 and later
End-of-life (see notification PSN-2013-03-892 )
•
•
•
•
Ten T1 ports
Power requirement: 0.15 A @ 48 V (7.2 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per logical interface.
Channelization: T1, FT1, N xDS0
•
•
•
•
•
•
Data service unit (DSU) and channel service unit (CSU) functionality
Ports configurable as clear channel T1 interfaces with 1.544-Mbps connectivity
Framing: Superframe (SF or D4) and Extended Superframe (ESF)
Supports B8ZS (bipolar 8-zero substitution) and AMI (alternate mark inversion) line coding
Local, remote, and payload loopback testing
ANSI T1.403 loopback support:
• Responds to embedded loopback commands upon receipt of an FDL command from remote end with loopup and loopdown at both line and payload level
• Insertion of loopback commands enables remote CSU/NIU/Smartjack to enter loopback and loopdown at both the line and payload level (ANSI and Telcordia)
• Inband loopback support:
• Responds to inband loopback commands at both the line and payload level (ANSI and
Telcordia)
• Insertion of inband loopback commands at both the line and payload level (ANSI and
Telcordia)
•
•
Clocking support of external (line) and internal
•
•
•
•
•
Buildout support of the following ranges:
0 through 132 (Line buildout is from 1 through 132 feet)
133 through 265 (Line buildout is from 133 through 265 feet)
266 through 398 (Line buildout is from 266 through 398 feet)
399 through 531 (Line buildout is from 399 through 531 feet)
532 through 655 (Line buildout is from 532 through 655 feet)
104 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Software features
Cables and connectors • 120-ohm RJ-48C connector (female)
LEDs
• Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
SNMP: T1 MIB and DS0 MIB •
•
•
•
Dynamic, arbitrary channel configuration
Full bit error rate test (BERT) patterns at T1 and DS0 levels
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Alarms, errors, and events
Instrumentation
(counters)
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Remote defect indication (RDI)
Loss of frame (LOF)
Loss of signal (LOS)
Bipolar violation (BPV)
Excessive zero (EXZ)
Line code violation (LCV)
Error seconds (ES)
Severely errored seconds (SES)
Severely errored frames (SEF)
Bit error event (BEE)
•
•
Layer 2 per-queue and per-channel packet and byte counters
24–hour history or error counter updated at 15–minute intervals
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
105
M10i Multiservice Edge Router Interface Module Reference
DS3 EOL PIC (M10i Router)
Software release • Junos OS Release 6.0 and later
End-of-life (see notification PSN-2010-02-648 )
Description
Hardware features
Software features
•
•
•
Two or four DS3 ports
Power requirement: 0.47 A @ 48 V (22.5 W)
Integrated DSU interoperability with leading DSU vendors
•
•
•
•
High-performance throughput on each port at speeds up to 44.736 Mbps, full duplex
C-bit framing
B3ZS line encoding
Subrate and scrambling:
•
•
•
Digital Link
Kentrox
Larscom
•
•
•
Per-port rate policing on input
Per-port rate shaping on output
Packet buffering, Layer 2 parsing
•
•
•
DS3 functionality:
C-bit framing
B3ZS line encoding
•
•
•
•
•
•
DS3 diagnostics and loopback control
DS3 alarm and event counting and detection
Per-packet counts and byte counts
Local and remote loopback testing, as well as BERT testing per DS3
DS3 far-end alarm and control (FEAC) channel support
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Point-to-Point Protocol (PPP)
Cables and connectors • Custom 10 ft (3.05 m) posilock SMB to BNC male cable, separate Rx and Tx (provided)
106 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Bit error rate test (BERT) functionality on PIC (you can configure one DS3 channel in BERT mode and configure the remaining channels to transmit and receive normal traffic)
Equipment failure (does not affect service)
Far-end block error (FEBE)
Frame error
Idle code, Idle received
Local and remote loopback
Loss of signal (LOS)
Out of frame (OOF)
Parity bit (P-bit) disagreements
Path parity error
Yellow alarm bit (X-bit) disagreements
Related
Documentation
• M10i PICs Description
•
E3 PIC (M10i Router)
Figure 6: 2-port E3 PIC Figure 7: 4-port E3 PIC
Software release
Description
•
•
2-port: Junos OS Release 6.0 and later
End-of-life (see notification PSN-2010-02-648 )
4-port: Junos OS Release 6.1 and later
•
•
•
Two or four E3 ports
Power requirement: 0.47 A @ 48 V (22.5 W)
Integrated DSU interoperability
Copyright © 2018, Juniper Networks, Inc.
107
M10i Multiservice Edge Router Interface Module Reference
Hardware features
Software features
•
•
•
•
•
•
•
•
•
High-density E3 (34.368-Mbps) connectivity
High-performance throughput on each port at speeds up to 34.368 Mbps, full duplex
Scrambling support
Subrate clocking support
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
Large MTUs, up to 9192 bytes
Local and remote loopback
•
•
•
•
•
•
Supports G-751 framing
E3 diagnostics and loopback control
E3 alarm and event counting and detection
DS3 diagnostics and loopback control
Bit error rate test (BERT); you can configure one port in BERT mode and configure the remaining channels to transmit and receive normal traffic
•
•
•
•
Encapsulations:
High-level Data Link Control (HDLC)
Frame Relay
Multiprotocol Label Switching (MPLS) circuit cross-connect (CCC)
Point-to-Point Protocol (PPP)
Cables and connectors • Custom 10 ft (3.05 m) posilock to BNC male cable, separate RX and TX
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
•
Alarm indication signal (AIS)
Equipment failure (does not affect service)
Frame error
Line code violation
Loss of signal (LOS)
Out of frame (OOF)
Yellow alarm bit (A-bit) disagreements
Related
Documentation
• M10i PICs Description
•
108 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
T1 EOL PIC (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 6.0 and later
End-of-life (see notification PSN-2013-03-891 )
•
•
•
•
Four T1 ports
Power requirement: 0.08 A @ 48 V (3.7 W)
Supports clear channel T1 per port (1.544 Mbps per channel)
Supports attenuation up to –12 dBm
•
•
Per-port loop timing
Onboard DSU functionality for T1 connectivity
•
•
•
•
•
•
•
•
•
•
ESF and SF framing
B8ZS and AMI coding
ESF CSU counters, WRT impairments, and CRC checking
Local DS1 line loopback, remote line loopback
Configurable clock source—internal or loop
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Point-to-Point Protocol (PPP)
Cables and connectors • 100-ohm RJ-48 connector
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
•
•
Alarm indication signal (AIS)
Bipolar violations
Excessive zeros
Far-end block errors (FEBE, E-bit errors)
Loss of frame (LOF), Loss of signal (LOS)
Yellow alarm bit (X-bit) disagreements
Copyright © 2018, Juniper Networks, Inc.
109
M10i Multiservice Edge Router Interface Module Reference
Related
Documentation
• M10i PICs Description
•
Gigabit Ethernet EOL PIC (M10i Router)
110
Software release
Description
Hardware features
•
•
•
•
Junos OS Release 6.1 and later
PE-1GE-LH
End-of-life (see notification PSN-2004-06-014 )
PE-1GE-LX
End-of-life (see notification PF-HW-0103-001 )
PE-1GE-SX
End-of-life (see notification PF-HW-0103-001 )
•
•
•
One Gigabit Ethernet port
Power requirement: 0.27 A @ 48 V (13.2 W)
Supports large Ethernet frame sizes for more efficient throughput across the intra-POP network
•
•
•
•
High-performance throughput on all ports at speeds up to 1 Gbps
Autonegotiation between Gigabit Ethernet circuit partners
Full-duplex mode
Maximum transmission units (MTUs) of up to 9192 bytes
Software features
•
•
•
•
Virtual Router Redundancy Protocol (VRRP) support
802.1Q virtual LANs (VLANs) support
64 source MAC address filters per port
960 destination MAC filters per port
Cables and connectors •
•
Duplex SC connector (TX and RX)
1000Base SFPs:
• 1000Base-LH (model number: SFP-1GE-LX)
•
•
1000Base-LX (model number: SFP-1GE-LH)
1000Base-SX (model number: SFP-1GE-SX)
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
LEDs Status LEDs, one bicolor:
•
•
•
Off—PIC not enabled
Green—PIC is operating normally
Red—PIC has an error or failure
Port LEDs, one pair per port:
•
•
Link—If green, the port is online; if there is no light, the port is down
Activity—If flashing green, the port is receiving data; if there is no light, the port might be on, but is not receiving data
Related
Documentation
• M10i PICs Description
Gigabit Ethernet IQ EOL PIC with SFP (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 6.0 and later
End-of-life (see notification PSN-2013-03-892 )
•
•
•
One Gigabit Ethernet port
Power requirement: 0.46 A @ 48 V (22 W)
Intelligent queuing (IQ) PICs support fine-grained queuing per-logical interface.
•
•
•
High-performance throughput at speeds up to 1 Gbps
Full-duplex mode
Large MTUs of up to 9192 bytes
•
•
Optical diagnostics and related alarms (Junos OS Release 8.2 and later)
Quality of service (QoS) per channel: Weighted round-robin (WRR), Random early drop (RED),
Weighted random early drop (WRED)
•
•
•
•
•
Virtual Router Redundancy Protocol (VRRP) support
802.1Q Virtual LANs
VLAN stacking and rewriting
MAC policing, accounting, and filters
Flexible Ethernet encapsulation
Copyright © 2018, Juniper Networks, Inc.
111
M10i Multiservice Edge Router Interface Module Reference
Cables and connectors • You can install any transceiver supported by the PIC.
•
•
Duplex LC/PC connector (RX and TX)
•
•
•
•
Fiber-optic small form-factor pluggable (SFP) transceivers:
1000Base-LH (model number: SFP-1GE-LH)
1000Base-LX (model number: SFP-1GE-LX)
1000Base-SX (model number: SFP-1GE-SX)
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• Copper small form-factor pluggable (SFP) transceivers: 1000Base-T (model number:
SFP-1GE-T)
Copper interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
LEDs •
•
•
•
•
Status LEDs, one tricolor:
Off—Not enabled.
Green—Online with no alarms or failures.
Yellow—Online with alarms for remote failures.
Red—Active with a local alarm; router has detected a failure.
•
•
•
Port LEDs, one per port:
Off—Port is down.
Green—Link is established.
Related
Documentation
• M10i PICs Description
•
Gigabit Ethernet IQ2 EOL PIC with SFP (M10i Router)
112
Software release
Description
Hardware features
• Junos OS Release 7.6R3 and later
End-of-life (see notification PSN-2013-03-892 )
•
•
Four Gigabit Ethernet ports
Power requirement: 0.65 A @ 48 V (31 W)
• High-performance throughput on each port: speeds up to 1 Gbps
•
•
Full-duplex mode
Large maximum transmission units (MTUs) of up to 9192 bytes
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Software features •
•
•
Intelligent handling of oversubscribed traffic
Optical diagnostics and related alarms
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Virtual Router Redundancy Protocol (VRRP) support
•
•
•
•
•
•
•
•
•
•
•
•
Hierarchical shaping
Fine-grained queuing and shaping per logical interface at both ingress and egress
802.1q virtual LANs (VLANs)
VLAN stacking and rewriting
Channels defined by two stacked VLAN tags
Multiple tag protocol identifiers (TPID) support
IP service for nonstandard TPID and stacked VLAN tags
802.1p rewrite per channel
Flexible mapping of channels and scheduler resources at both ingress and egress
Flexible Ethernet encapsulation
MAC learning, policing, accounting, and filtering
Cables and connectors
•
•
• You can install any transceiver supported by the PIC. For information about installing and removing transceivers, see the hardware guide for your router.
•
•
•
•
Duplex LC/PC connector (Rx and Tx)
Fiber-optic small form-factor pluggable transceivers (SFPs):
1000Base-LH (model number: SFP-1GE-LH)
1000Base-LX (model number: SFP-1GE-LX)
1000Base-SX (model number: SFP-1GE-SX)
Optical interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
• Copper small form-factor pluggable transceiver (SFP):1000Base-T (model number: SFP-1GE-T).
Copper interface specifications—see the Hardware Compatibility Tool at https://apps.juniper.net/hct/
NOTE: Do not install SONET/SDH SFPs in the Gigabit Ethernet port. The port will not recognize the SFP.
LEDs OK LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the router.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure.
APP LED, one bicolor:
•
•
Off—Monitoring application is not running.
Green—Monitoring application is running under acceptable load.
Port LEDs, one per port:
•
•
Off—Port is not enabled.
Green—Port is online with no alarms or failures.
Copyright © 2018, Juniper Networks, Inc.
113
M10i Multiservice Edge Router Interface Module Reference
Related
Documentation
• M10i PICs Description
•
Adaptive Services EOL PIC (M10i Router)
Software release
Description
Hardware features
•
•
Junos OS Release 6.1 and later
End-of-life (see notification PSN-2005-06-007 )
•
•
•
Supports tunnel services. This feature is included with the PIC and does not require an individual license.
Individual licenses must be purchased for additional services such as Network Address
Translation (NAT), stateful firewall, intrusion detection services (IDS), IPSec, J-Flow accounting, and voice services. For information about which services are supported by PIC and platform type, see the Junos OS Services Interfaces Library for Routing Devices .
Power requirement: 0.4 A @ 48 V (19 W)
•
•
•
Throughput speeds up to 800 Mbps of unidirectional traffic or 400 Mbps of bidirectional traffic, determined by packet size
Active monitoring on any interface up to 250,000 packets per second
Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
114 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Software features
LEDs
For a list of the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices .
Depending on your Junos OS Release and individual licenses, software features for this PIC can include:
• Stateful firewall with packet inspection
• Detects SYN attacks, ICMP and UDP floods, and ping-of-death attacks
•
•
•
•
NAT for IP addresses
Port Address Translation (PAT) for port numbers
J-Flow accounting exports cflowd version 5 and version 8 records
Tunnel services:
•
•
•
•
IP-IP unicast tunneling
GRE unicast tunneling—supports GRE fragmentation
PIM sparse mode unicast tunneling
Virtual loopback tunnel interface for VRF table lookup
•
•
•
L2TP services
•
•
IPSec encryption
Voice services:
Compressed Real-Time Transport Protocol (CRTP)
Compressed User Datagram Protocol (CUDP)
• Encapsulations:
•
•
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
Status LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the chassis.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure and no further harm can be done by removing it from the chassis.
Application LED, one tricolor:
•
•
•
Off—Service is not running.
Green—Service is running under acceptable load.
Yellow—Service is overloaded.
Related
Documentation
• M10i PICs Description
Copyright © 2018, Juniper Networks, Inc.
115
M10i Multiservice Edge Router Interface Module Reference
Adaptive Services II EOL PIC (M10i Router)
116
Software release
Description
Hardware features
Software features
LEDs
•
•
•
Junos OS Release 6.4 and later
Junos OS Release 9.4 and later supports the PE-AS2 PIC on the Enhanced Compact
Forwarding Engine Board (CFEB-E)
End-of-life (see notification PSN-2007-12-036 )
•
•
•
Supports tunnel services. This feature is included with the PIC and does not require an individual license.
Individual licenses must be purchased for additional services.
Power requirement: 0.4 A @ 48 V (19 W)
•
•
•
Support for up to 2000 service sets
Active monitoring on up to 1 million flows
Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
Depending on your Junos OS Release and individual licenses, software features for this PIC can include the features listed in
. For more information about the software features available for services PICs, see the Junos OS Services Interfaces Library for Routing
Devices .
Status LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the chassis.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure and no further harm can be done by removing it from the chassis.
Application LED, one bicolor:
•
•
•
Off—Service is not running.
Green—Service is running under acceptable load.
Yellow—Service is overloaded.
Table 23: Adaptive Services PICs Software Features
Software Feature
GRE Key
GRE dont-fragment
Adaptive Services II PIC
7.1
6.4
Stateful firewall with packet inspection: detects SYN attacks,
ICMP and UDP floods, and ping of death attacks
6.4
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Table 23: Adaptive Services PICs Software Features (continued)
Software Feature Adaptive Services II PIC
Network Address Translation (NAT) for IP addresses
Port Address Translation (PAT) for port numbers
6.4
6.4
IP Security (IPSec) encryption 6.4
Active flow monitoring exports cflowd version 5 and version 8 records
7.0
Active flow monitoring exports version 9 records, based on RFC
3954 (IP v4 templates only)
8.3
Passive flow monitoring
Passive flow collection
–
–
Flow-tap
Dynamic flow capture
8.1
–
Real-time performance monitoring
Link services
8.3
7.3
Tunnel services:
•
•
•
IP-IP unicast tunneling
GRE unicast tunneling—Supports GRE fragmentation
Protocol Independent Multicast (PIM) sparse mode unicast tunneling
6.4
Virtual tunnel interface for Layer 3 VPNs 6.4
Layer 2 Tunneling Protocol (L2TP)
Voice services:
• Compressed Real-Time Transport Protocol (CRTP)
Encapsulations:
•
•
Multilink Frame Relay (MLFR)
Multilink Point-to-Point Protocol (MLPP)
–
7.3
7.1
Related
Documentation
• M10i PICs Description
Copyright © 2018, Juniper Networks, Inc.
117
M10i Multiservice Edge Router Interface Module Reference
Adaptive Services II Layer 2 Services EOL PIC (M10i Router)
118
Software release
Description
Hardware features
Software features
LEDs
•
•
Junos OS Release 8.0R2 and later (Type 1)
End-of-life (see notification PSN-2008-11-080 )
NOTE: This PIC is not supported in Junos OS Release 8.1R1.
• Supports Layer 2 Service package only. Tunnel services are included with the PIC. Other services require an individual license.
• Power requirement: 0.4 A @ 48 V (19 W)
•
•
Support for up to 2000 service sets
Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
Depending on your Junos OS Release and individual licenses, software features for this PIC can include the features listed in
. For more information about the software features available for services PICs, see the Junos OS Services Interfaces Library for Routing Devices .
Status LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the chassis.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure and no further harm can be done by removing it from the chassis.
Application LED, one bicolor:
•
•
•
Off—Service is not running.
Green—Service is running under acceptable load.
Yellow—Service is overloaded.
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Table 24: Adaptive Services PICs Software Features
Software Feature
Adaptive Services II
PIC
Adaptive Services
II Layer 2 Services
PIC
GRE Key – –
–
–
GRE dont-fragment –
Stateful firewall with packet inspection: detects
SYN attacks, ICMP and UDP floods, and ping-of-death attacks
8.0R2
Network Address Translation (NAT) for IP addresses
8.0R2
Port Address Translation (PAT) for port numbers 8.0R2
IP Security (IPSec) encryption 8.0R2
Active flow monitoring exports cflowd version 5 and version 8 records
8.0R2
Active flow monitoring exports flow monitoring version 9 records, based on RFC 3954 (IP v4 templates only)
8.3
Passive flow monitoring
Passive flow collection
Flow-tap
Dynamic flow capture
–
–
–
–
Real-time performance monitoring
Link services
8.3
8.0R2
Tunnel services:
•
•
•
IP-IP unicast tunneling
GRE unicast tunneling—Supports GRE fragmentation
Protocol Independent Multicast (PIM) sparse mode unicast tunneling
8.0R2
Virtual tunnel interface for Layer 3 VPNs 8.0R2
Layer 2 Tunneling Protocol (L2TP) 8.0R2
–
–
–
–
–
–
–
–
–
–
8.0R2
8.0R2
–
8.0R2
Copyright © 2018, Juniper Networks, Inc.
119
M10i Multiservice Edge Router Interface Module Reference
Table 24: Adaptive Services PICs Software Features (continued)
Software Feature
Adaptive Services II
PIC
Adaptive Services
II Layer 2 Services
PIC
Voice services:
• Compressed Real-Time Transport Protocol
(CRTP)
Encapsulations:
•
•
Multilink Frame Relay (MLFR)
Multilink Point-to-Point Protocol (MLPP)
8.0R2
8.0R2
8.0R2
–
Related
Documentation
• M10i PICs Description
Adaptive Services II FIPS EOL PIC (M10i Router)
Software release
Description
Hardware features
•
•
Junos OS Release 7.2 and later
End-of-life (see notification PSN-20011-09-381 )
• Junos-FIPS requires an Adaptive Services II FIPS PIC for external IPSec connections. See the
Secure Configuration Guide for Common Criteria and Junos-FIPS for more information.
•
•
Supports tunnel services. This feature is included with the PIC and does not require an individual license.
Individual licenses must be purchased for additional services such as Network Address
Translation (NAT), stateful firewall, intrusion detection services (IDS), IPSec. J-Flow accounting, and voice services. For information about which services are supported by PIC and platform type, see the Junos OS Services Interfaces Library for Routing Devices .
• Power requirement: 0.4 A @ 48 V (19 W)
•
•
•
Support for up to 2000 service sets
Active monitoring on up to 1 million flows
Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
120 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Software features
LEDs
For a list of the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices .
Depending on your Junos OS release and individual licenses, software features for this PIC can include:
• Stateful firewall with packet inspection:
• Detects SYN attacks, ICMP and UDP floods, and ping-of-death attacks
•
•
•
•
•
•
•
•
NAT for IP addresses
Port Address Translation (PAT) for port numbers
J-Flow accounting exports cflowd version 5 and version 8 records
Tunnel services:
IP-IP unicast tunneling
GRE unicast tunneling—Supports GRE fragmentation
PIM sparse mode unicast tunneling
Virtual tunnel interface for Layer 3 VPNs
•
•
IPSec encryption
Voice services:
• Compressed Real-Time Protocol (CRTP)
•
•
•
Encapsulations:
Multilink Frame Relay (MLFR)
Multilink Point-to-Point Protocol (MLPP)
Status LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the chassis.
Green—PIC is operating normally.
Yellow—PIC is initializing.
Red—PIC has an error or failure and no further harm can be done by removing it from the chassis.
Application LED, one tricolor:
•
•
•
Off—Service is not running.
Green—Service is running under acceptable load.
Yellow—Service is overloaded.
Related
Documentation
• M10i PICs Description
Copyright © 2018, Juniper Networks, Inc.
121
M10i Multiservice Edge Router Interface Module Reference
ES EOL PIC (M10i Router)
122
Software release
Description
Hardware features
Software features
LEDs
Instrumentation
(counters)
•
•
Junos OS Release 6.0 and later
End-of-life (see notification PSN-2010-04-734 )
•
•
•
High-bandwidth encryption (in accordance with IPSec standards)
Power requirement: 0.21 A @ 48 V (10 W)
Support for IPSec encryption, decryption, and key calculation acceleration
NOTE: The ES PIC does not support reassembly and decryption of encrypted packets that were fragmented in an IPSec tunnel.
•
•
•
•
Extends the existing security functionality to Internet traffic at high-performance rates
Throughput at 800 Mbps, half duplex
1000 IPSec tunnels or 2000 IPSec security association (SA) pairs
Supports MTUs of up to 3900 bytes
For a list of the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices .
•
•
•
•
•
•
Support for IPv4
Authentication hash algorithms: MD-5 and SHA-1
Encryption algorithms: DES, 3-DES, and Null
Automated key management using Diffie-Hellman key establishment
Support for preshared key management
Authentication Header and Encapsulating Security Payload (ESP) independently or in bundle mode
Tunnel mode IPSec encryption and decryption for data traffic •
•
•
•
Transport mode IPSec encryption and decryption for control traffic
Static and dynamic security associations (SA) supported
SA lifetime configurable in seconds and kilobytes
One tricolor:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
•
•
•
•
Input and output bytes per tunnel
Total authentication failures
Total antireply failures
Total encryption ASIC errors per PIC
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Related
Documentation
• M10i PICs Description
Link Services EOL PIC (M10i Router)
Software release
Description
Hardware features
Software features
LEDs
•
•
•
•
Junos OS Release 6.0 and later
PE-LS-4
End-of-life (see notification PSN-2008-11-080 )
PE-LS-32
End-of-life (see notification PSN-2008-11-080 )
PE-LS-128
End-of-life (see notification PSN-2008-11-080 )
•
•
•
•
•
Power requirement: 0.17 A @ 48 V (8 W)
Three versions:
4 multilink bundles, 256 LFI links
32 multilink bundles, 256 LFI links
128 multilink bundles, 256 LFI links
• Multilink bonding, link fragmentation and interleaving (LFI), and tunneling
•
•
•
•
•
Rate limiting/policing per multilink bundle
Byte-wise load balancing across multilink bundles
Bonding T1 links enable service ranging from 1.5 Mbps through 12 Mbps
Bonding E1 links enable service ranging from 2 Mbps through 16 Mbps
Loopback function that encapsulates and de-encapsulates packets
For a list of the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices .
•
•
•
•
•
Protocol support:
Multilink PPP (MLPPP)
Multilink Frame Relay (MLFR)—FRF.15 and FRF.16
Link fragmentation and interleaving (LFI)—FRF.12
LFI over MLPPP
•
•
•
IP-IP unicast tunneling
GRE unicast tunneling
PIM sparse mode unicast tunneling
One bicolor:
•
•
•
Off—PIC is offline
Green—PIC is online and at least one configured bundle is operating
Yellow—PIC is online, but no configured bundles are operating
Copyright © 2018, Juniper Networks, Inc.
123
M10i Multiservice Edge Router Interface Module Reference
Related
Documentation
• M10i PICs Description
Monitoring Services EOL PIC (M10i Router)
124
Software release
Description
Hardware features
Software features
•
•
Junos OS Release 6.1 and later
End-of-life (see notification PSN-2005-06-007 )
•
•
•
•
Active traffic monitoring
Power requirement: 0.19 A @ 48 V (9 W)
Monitors IPv4 packets
Support for collecting and exporting cflowd records
•
•
Monitors up to 100,000 packets per second
Support for MTUs up to 4474 bytes for SONET interfaces
For a list of the software features available for services PICs, see the Junos OS Services Interfaces
Library for Routing Devices .
•
•
•
•
•
Load distribution across multiple PICs cflowd version 5 support
Provides start and end times of each export
•
•
Supports firewall filtering and filter-based forwarding (FBF)
Encapsulations:
High-Level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
Cables and connectors • DB-9 diagnostic serial console port
LEDs Status LED, one tricolor:
•
•
•
•
Off—PIC is offline and it is safe to remove it from the chassis
Green—PIC is operating normally
Yellow—PIC is initializing
Red—PIC has an error or failure and no further harm can be done by removing it from the chassis
Application LED, one tricolor:
•
•
•
Off—Flow collector is not running
Green—Flow collector is running under acceptable load
Yellow—Flow collector is overloaded
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Related
Documentation
• M10i PICs Description
SONET/SDH OC3c/STM1 EOL PIC (M10i Router)
Software release
Description
Hardware features
Software features
• Junos OS Release 6.0 and later (Type 1)
NOTE: Although the illustration shows a multimode PIC, a multimode PIC and a single-mode intermediate reach PIC are both supported.
•
•
Junos OS Release 9.4 and later supports the PE-4OC3-SON-MM and PE-4OC3-SON-SMIR
PICs on the Enhanced Compact Forwarding Engine Board (CFEB-E)
End-of-life (see notification PSN-2007-12-037 )
•
•
Two or four OC3 ports
Power requirements: 0.49 A/48 V @ 23.7 W
•
•
•
•
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
•
•
•
•
•
•
•
•
•
•
•
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
Duplex SC/PC connector (Rx and Tx)
SONET/SDH OC3/STM1 SFPs:
•
•
Intermediate Reach (model number: SFP-OC3-IR)
Multimode (model number: SFP-OC3-SR)
Optical interface specifications—See
“SONET/SDH OC3/STM1 Optical Interface Specifications” on page 14
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the CLI Explorer .
Copyright © 2018, Juniper Networks, Inc.
125
M10i Multiservice Edge Router Interface Module Reference
126
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
SONET/SDH OC3/STM1 Optical Interface Specifications on page 14
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
SONET/SDH OC12c/STM4 EOL PIC (M10i Router)
Software release
Description
Hardware features
Software features
•
•
•
•
Junos OS Release 6.0 and later
Junos OS Release 9.4 and later supports the PE-1OC12-SON-MM and PE-1OC12-SON-SMIR
PICs on the Enhanced Compact Forwarding Engine Board (CFEB-E)
PE-1OC12-SON-MM
End-of-life (see notification PSN-2007-12-037 )
PE-1OC12-SON-SMIR
End-of-life (see notification PSN-2007-12-037 )
•
•
One port
Power requirement: 0.23 A @ 48 V (10.8 W)
•
•
•
•
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
•
•
•
•
•
•
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
•
•
•
•
•
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
Duplex SC/PC connector (Rx and Tx)
SONET/SDH OC12/STM4 SFPs:
•
•
Intermediate Reach (model number: SFP-OC12-IR)
Multimode (model number: SFP-OC12-SR)
Optical interface support—See
“SONET/SDH OC12/STM4 Optical Interface Specifications” on page 16
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the CLI Explorer .
Copyright © 2018, Juniper Networks, Inc.
127
M10i Multiservice Edge Router Interface Module Reference
128
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
SONET/SDH OC12/STM4 Optical Interface Specifications on page 16
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
SONET/SDH OC12/STM4 Enhanced IQ (IQE) EOL PIC with SFP (M10i Router)
STM-4/OC-1
2 SFP
Software release
Description
Hardware features
Software features
• Junos OS Release 10.2 and later (Type 1)
End-of-life (see notification PSN-2013-03-892 )
•
•
•
•
One OC12/STM4 port
SONET or SDH is configurable on a per-port granularity
Power requirement: 0.58 A @ 48 V (27.8 W)
Model number: PB-1OC12-STM4-IQE-SFP
• Port is numbered 0.
•
•
Quality of service (QoS) per channel: weighted round-robin (WRR), random early detection
(RED), weighted random early detection (WRED)
Enhanced fine-grained queuing per logical interface. See the Class of Service Feature Guide for
Routing Devices and EX9200 Switches for more information about class of service features.
•
•
•
Packet buffering, Layer 2 parsing
Local line and remote payload loopback testing
Encapsulations:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Extended Frame Relay for CCC and TCC
Flexible Frame Relay
Frame Relay
Frame Relay for CCC
Frame Relay for TCC
Frame Relay port CCC
High-Level Data Link Control (HDLC)
HDLC framing for CCC
HDLC framing for TCC
MPLS CCC
MPLS TCC
Multilink Frame Relay (MLFR) UNI NNI (MFR FRF.16)
Point-to-Point Protocol (PPP)
PPP for CCC
PPP for TCC
• Encapsulations available only for DS1:
• Multilink Frame Relay end-to-end (MLFR FRF.15)
Copyright © 2018, Juniper Networks, Inc.
129
M10i Multiservice Edge Router Interface Module Reference
•
•
Multilink PPP (MLPPP)
PPP over Frame Relay
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC12/STM4 fiber-optic SFP transceivers:
•
•
Short reach (model number: SFP-OC12-SR)
Intermediate reach (IR-1) (model number: SFP-OC12-IR)
• Long reach (LR-1) (model number: SFP-OC12-LR)
Optical interface specifications—see
“SONET/SDH OC12/STM4 Optical Interface Specifications” on page 16
LEDs One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
130 Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
Alarms, errors, and events
Instrumentation
(counters)
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Loss of frame (LOF)
Loss of light (LOL)
Loss of pointer (LOP)
Loss of signal (LOS)
Payload label mismatch (PLM-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
Remote error indication (REI)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
• SDH alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Higher order path—alarm indication signal (HP-AIS)
Higher order path—far-end receive failure (HP-FERF)
Higher order path—payload label mismatch (HP-PLM)
Higher order path—loss of pointer (HP-LOP)
Higher order path—remote defect indication (HP-RDI)
Higher order path—unequipped (HP-UNEQ)
Loss of frame (LOF)
Loss of light (LOL)
Loss of signal (LOS)
Multiplex section—alarm indication signal (MS-AIS)
Multiplex section—far-end receive failure (MS-FERF)
Multiplex section—remote defect indication (MS-RDI)
Multiplex section—remote error indication (MS-REI)
Phase lock loop (PLL)
Remote error indication (REI)
Severely errored frame (SEF)
• Layer 2 per-queue and per-channel packet and byte counters
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
131
M10i Multiservice Edge Router Interface Module Reference
SONET/SDH OC48c/STM16 EOL PIC with SFP
132
Software release
Description
Hardware features
Software features
• Junos OS Release 6.4 and later
End-of-life (see notification PSN-2013-03-891 )
•
•
One OC48 port
Power requirement: 0.86 A @ 48 V (41.4 W)
•
•
•
•
Multiplexing and demultiplexing
Rate policing on input
Rate shaping on output
Packet buffering, Layer 2 parsing
•
•
•
•
•
•
•
Optical diagnostics and related alarms
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
•
•
•
•
•
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
Cables and connectors •
•
Duplex LC/PC connector (Rx and Tx)
SONET/SDH OC48/STM16 small form-factor pluggable (SFP) transceivers:
• Short reach (SR-1) (model number: SFP-1OC48-SR)
•
•
Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
Long reach (LR-1) (model number: SFP-1OC48-LR)
Optical interface specifications—see
“SONET/SDH OC48/STM16 Optical Interface
NOTE: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the CLI Explorer .
Copyright © 2018, Juniper Networks, Inc.
Chapter 13: End-of-Life PIC Descriptions
LEDs
Alarms, errors, and events
One tricolor per port:
•
•
•
•
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected a failure
• SONET alarms:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
Payload mismatch (path label mismatch) (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SDH alarms:
Multiplex section alarm indication signal (MS-AIS)
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1
Bit interleaved parity (BIP) error B2
Bit interleaved parity (BIP) error B3
Loss of frame (LOF)
Loss of pointer (HP-LOP)
Loss of signal (LOS)
Multiplex section remote error indication (MS-REI)
Higher path label mismatch (HP-PLM)
Higher path unequipped (HP-UNEQ)
Multiplex section remote defect indication (MS-RDI)
Higher path remote defect indication (HP-RDI)
• Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
• Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
Related
Documentation
• M10i PICs Description
•
Copyright © 2018, Juniper Networks, Inc.
133
M10i Multiservice Edge Router Interface Module Reference
134 Copyright © 2018, Juniper Networks, Inc.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Table of Contents
- 7 List of Figures
- 9 List of Tables
- 11 About the Documentation
- 11 Documentation and Release Notes
- 11 Documentation Conventions
- 13 Documentation Feedback
- 14 Requesting Technical Support
- 14 Self-Help Online Tools and Resources
- 14 Opening a Case with JTAC
- 17 Part 1: Overview
- 19 Chapter 1: M10i Interface Modules Support
- 19 M10i PICs Supported
- 22 M10i End-of-Life PICs Supported
- 24 M10i PIC/CFEB Compatibility
- 29 Chapter 2: Network Interface Specifications
- 29 Determining Transceiver Support and Specifications for M Series and T Series Routers
- 29 Fast Ethernet 100BASE-FX Optical Interface Specifications
- 30 SONET/SDH OC3/STM1 Optical Interface Specifications
- 30 SONET/SDH OC3/STM1 Specifications
- 31 SONET/SDH OC3/STM1 Intermediate Reach (IR-1) Specifications
- 31 SONET/SDH OC3/STM1 Long Reach (LR-1) Specifications
- 32 SONET/SDH OC12/STM4 Optical Interface Specifications
- 32 SONET/SDH OC12/STM4 Short Reach (SR-1) Specifications
- 32 SONET/SDH OC12/STM4 Intermediate Reach (IR-1) Specifications
- 33 SONET/SDH OC12/STM4 Long Reach (LR-1) Specifications
- 33 SONET/SDH OC12/STM4 Long Reach (LR-2) Specifications
- 34 SONET/SDH OC48/STM16 Optical Interface Specifications
- 34 SONET/SDH OC48/STM16 Short Reach (SR-1) Specifications
- 34 SONET/SDH OC48/STM16 Intermediate Reach (IR-1) Specifications
- 35 SONET/SDH OC48/STM16 Long Reach (LR-1) Specifications
- 35 SONET/SDH OC48/STM16 Long Reach (LR-2) Specifications
- 37 Chapter 3: Cable Pinouts
- 37 RJ-48 Cable Pinouts for E1 and T1 PICs
- 41 Part 2: PIC Descriptions
- 43 Chapter 4: ATM2 IQ PIC Descriptions
- 43 ATM2 DS3 IQ PIC (M10i Router)
- 45 ATM2 OC3/STM1 IQ PIC (M10i Router)
- 46 ATM2 OC12/STM4 IQ PIC (M10i Router)
- 49 Chapter 5: Channelized Enhanced IQ (IQE) PIC Descriptions
- 49 Channelized DS3 and E3 Enhanced IQ (IQE) PIC (M10i Router)
- 52 Channelized E1/T1 Enhanced IQ (IQE) PIC (M10i Router)
- 54 Channelized OC3/STM1 Enhanced IQ (IQE) with SFP (M10i Router)
- 59 Channelized OC12/STM4 Enhanced IQ (IQE) PIC with SFP (M10i Router)
- 65 Chapter 6: Circuit Emulation PIC Descriptions
- 65 Channelized OC3/STM1 Circuit Emulation PIC with SFP (M10I Router)
- 68 E1/T1 Circuit Emulation PIC (M10i Router)
- 73 Chapter 7: DS3, E1, E3, and T1 PIC Descriptions
- 73 DS3/E3 Enhanced IQ (IQE) PIC (M10i Router)
- 75 E1 PIC (M10i Router)
- 77 E3 IQ PIC (M10i Router)
- 79 Chapter 8: Ethernet PIC Descriptions
- 79 Fast Ethernet PICs (M10i Router)
- 81 Gigabit Ethernet PIC with SFP (M10i Router)
- 83 Chapter 9: Ethernet Enhanced IQ2 (IQ2E) PIC Descriptions
- 83 Gigabit Ethernet Enhanced IQ2 (IQ2E) PIC with SFP (M10i Router)
- 87 Chapter 10: Services PIC Descriptions
- 87 Multiservices 100 PIC (M10i Router)
- 89 Tunnel Services PIC (M10i Router)
- 91 Chapter 11: Serial PIC Descriptions
- 91 EIA-530 PIC (M10i Router)
- 93 Chapter 12: SONET/SDH PIC Descriptions
- 93 SONET/SDH OC3/STM1 PIC with SFP (M10i Router)
- 96 SONET/SDH OC3/STM1 Enhanced IQ (IQE) PIC with SFP (M10i Router)
- 98 SONET/SDH OC3/STM1 (Multi-Rate) PIC with SFP (M10i Router)
- 101 SONET/SDH OC12/STM4 (Multi-Rate) PIC with SFP (M10i Router)
- 105 Chapter 13: End-of-Life PIC Descriptions
- 106 ATM DS3 EOL PIC (M10i Router)
- 107 ATM E3 EOL PIC (M10i Router)
- 109 ATM2 E3 IQ EOL PIC (M10i Router)
- 110 Multichannel DS3 EOL PIC (M10i Router)
- 112 Channelized DS3 IQ EOL PIC (M10i Router)
- 113 Channelized E1 IQ EOL PIC (M10i Router)
- 115 Channelized OC3 IQ EOL PIC (M10i Router)
- 116 Channelized OC12 IQ EOL PIC (M10i Router)
- 118 Channelized STM1 IQ EOL PIC (M10i Router)
- 120 Channelized T1 IQ EOL PIC (M10i Router)
- 122 DS3 EOL PIC (M10i Router)
- 123 E3 PIC (M10i Router)
- 125 T1 EOL PIC (M10i Router)
- 126 Gigabit Ethernet EOL PIC (M10i Router)
- 127 Gigabit Ethernet IQ EOL PIC with SFP (M10i Router)
- 128 Gigabit Ethernet IQ2 EOL PIC with SFP (M10i Router)
- 130 Adaptive Services EOL PIC (M10i Router)
- 132 Adaptive Services II EOL PIC (M10i Router)
- 134 Adaptive Services II Layer 2 Services EOL PIC (M10i Router)
- 136 Adaptive Services II FIPS EOL PIC (M10i Router)
- 138 ES EOL PIC (M10i Router)
- 139 Link Services EOL PIC (M10i Router)
- 140 Monitoring Services EOL PIC (M10i Router)
- 141 SONET/SDH OC3c/STM1 EOL PIC (M10i Router)
- 143 SONET/SDH OC12c/STM4 EOL PIC (M10i Router)
- 145 SONET/SDH OC12/STM4 Enhanced IQ (IQE) EOL PIC with SFP (M10i Router)
- 148 SONET/SDH OC48c/STM16 EOL PIC with SFP