ELPRO 115S Series Quick Setup Manual
Add to My manuals2 Pages
ELPRO 115S Series is a versatile IoT device that can be used to collect data from sensors and control actuators. It has a variety of input and output options, including digital inputs, digital outputs, analog inputs, analog outputs, and a relay output. This makes it suitable for use in a wide range of applications, such as industrial automation, building automation, and remote monitoring.
The 115S Series is also highly configurable, allowing you to customize it to meet your specific needs. You can use the ELPRO E-Series configuration utility to set up the device's parameters, such as the Modbus address, the termination switch, and the input and output modes.
advertisement
▼
Scroll to page 2
inst_115S_1.5.doc © ELPRO Technologies. June 2007. V1.5 115S-Series Quick setup guide Connection to a Modbus master Connection to E-Series Radio ADDRESSING ADDRESSING Set a unique Modbus slave address for each 115S connected to the Modbus master. Example here address = 01. x10 x1 x10 POWER B A - + Modbus master 115S 115S Connect power: (10.8-15.6 VDC) to ‘+’ and EARTH to ‘-‘. modbus power modbus modbus power power power x1 POWER earth Master power supply 115S-11: 300mA max 115S-12: 600mA max 115S-13: 650mA max 115S sup 115S 115S Connect power: (10.8-15.6 VDC) to ‘+’ and EARTH to ‘-‘. Battery 12VDC bat modbus power modbus modbus power power power earth ø 2mm EARTH wire RS485 B A - + E-series radio 115S 115S power supply 12VDC Master power supply Address switches must be 00 for E-Series protocol. 115S-11: 300mA max 115S-12: 600mA max 115S-13: 650mA max ø 2mm EARTH wire RS485 Up = terminate B A - + A, B: Connect RS485 (Modbus) Down = unterminated ON RS485 Power and termination Modbus switch. connector 115S Modbus master A B A B B 115S A B Termination switch up (terminated) B A - + A, B: Connect RS485 (Modbus) Down = unterminated ON E-Series radio 115S A Up = terminate RS485 Power and termination Modbus switch. connector 115S (RS485terminated) A B A B 115S A B 115S A B Termination switch up (terminated) 120Ω Consult user manual for Modbus addresses. Set up using ELPRO E-Series configuration utility. inst_115S_1.5.doc © ELPRO Technologies. June 2007. V1.5 115S-Series Quick setup guide - Wiring 115S-11 DIGITAL INPUTS 115S Module V+ 115S-12 (Select using config software) DIO1 Voltage-free contact Power supply DIO2 Transistor switch device CURRENT SOURCE OUTPUT 115S-13 ALS +24V Loop powered sensor - + V+ EARTH 115S-13 115S-12 DIFFERENTIAL CURRENT INPUTS + Externally powered sensor AIN2 AOT1 AIN3 AOT2 + AGND (Select using config software) EARTH AOT2 - 115S-12 _ + + - - + AI- PLC + Externally powered sensor ALS +24V Max 30VDC 0.25A V- AOT1 (Select using config software) + AI+ ALS +24V AIN2 DIFFERENTIAL VOLTAGE INPUTS DC Load CURRENT SINK OUTPUT 115S-13 AIN1 DIO2 PLC SINGLE-ENDED CURRENT INPUTS (Default configuration) DIGITAL OUTPUTS COM - AGND VV- Loop powered 115S-12 sensor ALS +24V - + DIO1 AI AIN4 V- 115S Module (Default configuration) ALS +24V AIN1 AIN1 AGND VAGND V- AIN2 AIN3 SINGLE-ENDED VOLTAGE INPUTS AIN4 VOLTAGE OUTPUT (Select using config software) (Select using config software) Sensors with voltage signals 115S-12 AGND PLC VOLTAGE INPUT 115S-13 VALS +24V ALS +24V AIN2 Sensor with voltage signal AI AOT1 AIN1 AOT2 + + AGND V- V- AGND - COM
advertisement
Related manuals
advertisement