advertisement
Product datasheet
PT-FIT 35/220…240 I
POWERTRONIC PT-FIT I | ECG for HID lamps, with cable clamp
Product family features
_
_
_
_
_
_
_
Energy Efficiency Index EEI: A2
Supply voltage: 220…240 V
Line frequency: 50…60 Hz
RI suppression: to EN 55015/CISPR 15
Safety: to EN 61347-2-12
Line harmonics according to EN 61000-3-2
Immunity according to EN 61547
__
Product family benefits
_
_
_
ECG with ergonomic strain relief for correct installation in suspended ceilings
Optimized cost/benefit factor
Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
Areas of application
_
_
_
Shop lighting
Health and fitness areas (in luminaires with protection class IP66 or higher)
Effect and accent lighting
September 29, 2021, 21:48:50
PT-FIT 35/220…240 I
© 2021, OSRAM GmbH. All rights reserved.
Page 1 of 7
Product datasheet
__
Technical data
Electrical data
Lamp wattage
Maximum output power
Line current
Ignition voltage
Operating frequency
System wattage
Efficiency in full-load
Input voltage AC
Nominal voltage
Mains frequency
Power factor
λ
Inrush current
Max. ECG no. on circuit breaker 10 A (B)
Max. ECG no. on circuit breaker 16 A (B)
Max. no. of ECGs on 16A MCB with EBN-OS
Protective conductor current
U-OUT (working voltage)
Max. working voltage between LH and LL
Max. working voltage betw. LL/LH & earth
Max. capacitance of wire ECG/lamp
1) At 230 VAC
2) Minimum
3) twidth = 150 µs (measured at 50 % Ipeak)
4) Type B
Dimensions & weight
30 A
3)
15
4)
26
4)
65
4)
0.3 mA
250 V
250 V
250 V
120 pF
39 W
39 W
0.19 A
1)
4.5 kVp
0.200…0.240 kHz
43.00 W
91 %
198…264 V
220…240 V
50…60 Hz
0.95
2)
Length
September 29, 2021, 21:48:50
PT-FIT 35/220…240 I
172.0 mm
© 2021, OSRAM GmbH. All rights reserved.
Page 2 of 7
Product datasheet
Width
Height
Mounting hole spacing, length
Cable cross-section, input side
Cable cross-section, output side
Wire preparation length, input side
Wire preparation length, output side
Product weight
1) With ferrule / Without ferrule
Colors & materials
Casing material
Temperatures & operating conditions
Ambient temperature range
Maximum temperature at tc test point
__
Lifespan
ECG lifetime
1) At maximum Tc / 10% failure rate
Additional product data
Design / version
Suitable for lamp power (1 lamp)
Capabilities
Max. cable length to lamp/LED module
Overheating protection
ECG reset time
Cable/wire types, input side
Cable/wire types, output side
Dimmable
Restriction on ignition time
Suitable for fixtures with prot. class
Intended for no-load operation
Certificates & standards
Approval marks – approval
83.0 mm
33.0 mm
163.0 mm
0.75…1.5 / 0.75…2.5 mm²
1)
0.75…1.5 / 0.75…2.5 mm²
1)
5.5…6.5 mm
5.5…6.5 mm
285.00 g
Plastic
-15…+60 °C
75 °C
30000 h
1)
With cable clamp
39 W
1.5 m
Power reduction and switch off at T > 75 °C at the tc point
> 0.5 s
NYM-J 3x1.5 / NYM-J 3x2.5 / H05VV-F 3x1.5 /
NHXMH-J 3x1.5 mm²
SIHF-J 3x1.5 / SIHF-J 3x2.5 / SIHSI 3x1.0 mm²
No
20 min
I
No
VDE / VDE-EMC / EAC / C-Tick
September 29, 2021, 21:48:50
PT-FIT 35/220…240 I
© 2021, OSRAM GmbH. All rights reserved.
Page 3 of 7
Product datasheet
Type of protection
EEI – Energy Label
Standards
Logistical data
Commodity code
Wiring Diagram
IP20
A2
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN
61000-3-2/Acc. to EN 61547/Acc. to EN 62493
850410809000
__
342376_Downlight Setup
Safety advice
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.
Attention!
For safety reasons disconnect the device before replacing the lamp!
Download Data
September 29, 2021, 21:48:50
PT-FIT 35/220…240 I
© 2021, OSRAM GmbH. All rights reserved.
Page 4 of 7
__
Product datasheet
File
Product Datasheet
321397_ATI PT-FIT 35220-240 I (G+GB)
Tender documents
339884_Tender Document for POWERTRONIC EVG.eng
Certificates
335124_VDE-Marks approval
Certificates
554891_EAC PT family
Declarations of conformity
Powertronic UK DoC 4278196 260121
Declarations of conformity
Powertronic CE 3363432 100821
Declarations of conformity
VD EMC Certificate 40025469
Operating instructions
590731_EAC - PTI I PT-FIT I
CAD data 3-dim
321673_CAD PTI-FIT 3570 I
CAD data 3-dim
321674_CAD PTI-FIT 3570 I
CAD data 3-dim
321675_CAD PTI-FIT 3570 I
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive
2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Logistical Data
Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height)
Volume Gross weight
437 mm x 100 mm x 365 mm 15.95 dm³ 6130.00 g 4008321377661 PT-FIT 35/220…240 I Shipping carton box
20
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
September 29, 2021, 21:48:50
PT-FIT 35/220…240 I
© 2021, OSRAM GmbH. All rights reserved.
Page 5 of 7
__
Product datasheet
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
September 29, 2021, 21:48:50
PT-FIT 35/220…240 I
© 2021, OSRAM GmbH. All rights reserved.
Page 6 of 7
__
Product datasheet
PT-FIT 35/220…240 I
POWERTRONIC PT-FIT I | ECG for HID lamps, with cable clamp
Product name
PT-FIT 35/220…240 I
Lamp group
HCI-T 35W
HCI-TC 35W
HCI-TF 35W
September 29, 2021, 21:48:50
PT-FIT 35/220…240 I
© 2021, OSRAM GmbH. All rights reserved.
Page 7 of 7