Energy Efficiency Index EEI: A2

Supply voltage: 220…240 V

Line frequency: 50…60 Hz

RI suppression: to EN 55015/CISPR 15

Safety: to EN 61347-2-12

Line harmonics according to EN 61000-3-2

Immunity according to EN 61547

__

Product family benefits

_

_

_

ECG with ergonomic strain relief for correct installation in suspended ceilings

Optimized cost/benefit factor

Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)

Areas of application

_

_

_

Shop lighting

Health and fitness areas (in luminaires with protection class IP66 or higher)

Effect and accent lighting

September 29, 2021, 21:48:50

PT-FIT 35/220…240 I

© 2021, OSRAM GmbH. All rights reserved.

Page 1 of 7

Product datasheet

__

Technical data

Electrical data

Lamp wattage

Maximum output power

Line current

Ignition voltage

Operating frequency

System wattage

Efficiency in full-load

Input voltage AC

Nominal voltage

Mains frequency

Power factor

λ

Inrush current

Max. ECG no. on circuit breaker 10 A (B)

Max. ECG no. on circuit breaker 16 A (B)

Max. no. of ECGs on 16A MCB with EBN-OS

Protective conductor current

U-OUT (working voltage)

Max. working voltage between LH and LL

Max. working voltage betw. LL/LH & earth

Max. capacitance of wire ECG/lamp

1) At 230 VAC

2) Minimum

3) twidth = 150 µs (measured at 50 % Ipeak)

4) Type B

Dimensions & weight

30 A

3)

15

4)

26

4)

65

4)

0.3 mA

250 V

250 V

250 V

120 pF

39 W

39 W

0.19 A

1)

4.5 kVp

0.200…0.240 kHz

43.00 W

91 %

198…264 V

220…240 V

50…60 Hz

0.95

2)

Length

September 29, 2021, 21:48:50

PT-FIT 35/220…240 I

172.0 mm

© 2021, OSRAM GmbH. All rights reserved.

Page 2 of 7

Product datasheet

Width

Height

Mounting hole spacing, length

Cable cross-section, input side

Cable cross-section, output side

Wire preparation length, input side

Wire preparation length, output side

Product weight

1) With ferrule / Without ferrule

Colors & materials

Casing material

Temperatures & operating conditions

Ambient temperature range

Maximum temperature at tc test point

__

Lifespan

ECG lifetime

1) At maximum Tc / 10% failure rate

Additional product data

Design / version

Suitable for lamp power (1 lamp)

Capabilities

Max. cable length to lamp/LED module

Overheating protection

ECG reset time

Cable/wire types, input side

Cable/wire types, output side

Dimmable

Restriction on ignition time

Suitable for fixtures with prot. class

Intended for no-load operation

Certificates & standards

Approval marks – approval

83.0 mm

33.0 mm

163.0 mm

0.75…1.5 / 0.75…2.5 mm²

1)

0.75…1.5 / 0.75…2.5 mm²

1)

5.5…6.5 mm

5.5…6.5 mm

285.00 g

Plastic

-15…+60 °C

75 °C

30000 h

1)

With cable clamp

39 W

1.5 m

Power reduction and switch off at T > 75 °C at the tc point

> 0.5 s

NYM-J 3x1.5 / NYM-J 3x2.5 / H05VV-F 3x1.5 /

NHXMH-J 3x1.5 mm²

SIHF-J 3x1.5 / SIHF-J 3x2.5 / SIHSI 3x1.0 mm²

No

20 min

I

No

VDE / VDE-EMC / EAC / C-Tick

September 29, 2021, 21:48:50

PT-FIT 35/220…240 I

© 2021, OSRAM GmbH. All rights reserved.

Page 3 of 7

Product datasheet

Type of protection

EEI – Energy Label

Standards

Logistical data

Commodity code

Wiring Diagram

IP20

A2

Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN

61000-3-2/Acc. to EN 61547/Acc. to EN 62493

850410809000

__

342376_Downlight Setup

Safety advice

Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.

Attention!

For safety reasons disconnect the device before replacing the lamp!

Download Data

September 29, 2021, 21:48:50

PT-FIT 35/220…240 I

© 2021, OSRAM GmbH. All rights reserved.

Page 4 of 7

__

Product datasheet

File

Product Datasheet

321397_ATI PT-FIT 35220-240 I (G+GB)

Tender documents

339884_Tender Document for POWERTRONIC EVG.eng

Certificates

335124_VDE-Marks approval

Certificates

554891_EAC PT family

Declarations of conformity

Powertronic UK DoC 4278196 260121

Declarations of conformity

Powertronic CE 3363432 100821

Declarations of conformity

VD EMC Certificate 40025469

Operating instructions

590731_EAC - PTI I PT-FIT I

CAD data 3-dim

321673_CAD PTI-FIT 3570 I

CAD data 3-dim

321674_CAD PTI-FIT 3570 I

CAD data 3-dim

321675_CAD PTI-FIT 3570 I

Ecodesign regulation information:

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive

2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Logistical Data

Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height)

Volume Gross weight

437 mm x 100 mm x 365 mm 15.95 dm³ 6130.00 g 4008321377661 PT-FIT 35/220…240 I Shipping carton box

20

The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.

September 29, 2021, 21:48:50

PT-FIT 35/220…240 I

© 2021, OSRAM GmbH. All rights reserved.

Page 5 of 7

__

Product datasheet

Disclaimer

Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.

September 29, 2021, 21:48:50

PT-FIT 35/220…240 I

© 2021, OSRAM GmbH. All rights reserved.

Page 6 of 7

__

Product datasheet

PT-FIT 35/220…240 I

POWERTRONIC PT-FIT I | ECG for HID lamps, with cable clamp

Product name

PT-FIT 35/220…240 I

Lamp group

HCI-T 35W

HCI-TC 35W

HCI-TF 35W

September 29, 2021, 21:48:50

PT-FIT 35/220…240 I

© 2021, OSRAM GmbH. All rights reserved.

Page 7 of 7

advertisement

Related manuals

advertisement